Records from 1987 to 2017. Most recent: inspection, 8 March 2017.
Inspection history · 55
8 March 2017
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6101156
14 January 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6069924
22 April 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5856636
28 September 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5725831
1 August 2014
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4934245
1 March 2010
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3688019
1 February 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3670067
3 April 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3445714
9 March 2009
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3430219
4 September 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3317615
30 August 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3315794
9 June 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3232409
6 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3110549
14 October 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3079073
30 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2811167
30 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2811402
30 October 2006
In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2813810
3 April 2006
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2615639
10 December 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2549111
18 October 2005
ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2517055
10 February 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2289762
6 January 2005
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2270361
1 October 2004
ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2211256
9 February 2004
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2002790
6 December 2003
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1956928
8 March 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1754354
7 March 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1754217
9 November 2002
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1703060
5 September 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1671118
19 June 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1632981
16 June 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1631777
13 June 2002
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1630696
13 October 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 294557
3 May 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 289669
7 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280877
23 March 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 275880
2 July 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 430135
1 September 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 394770
15 June 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 379438
15 June 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646045
12 June 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 379392
13 February 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 138914
28 November 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 362714
2 June 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 481683
20 July 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 352084
16 January 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 348315
8 June 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 344208
31 December 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 493601
3 May 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 336891
19 June 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 331037
25 November 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 437922
10 May 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 323243
25 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 467753
22 October 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 459545
22 March 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 315043
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 January 2017
Resolved
After any survey of the ship under article 14 has been completed, no change shall be made to the structure without the sanction of the administration. PSCO observed a 3m x 3m area on the vsls stbd side at cargo deck #2 frame 133-134 that was severely indented. it appeared to be as much as 4 inches and warped the frame as seen from the interior. Vessel failed to provide class documentation.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 January 2017
Resolved 8 March 2017
Resolution: Sector San Diego received documentation from class attesting to the satisfactory operation of damaged hull. Cleared 01 deficiencies. 00 deficiencies remain outstanding.
Fire Fighting › Fire Hydrants › Condition
Issued 1 February 2010
Resolved
Aft most interior fire hydrant on the Upper deck was incapable of providing water to fire hose due to obstruction in valve caused by sediment build-up. Crew removed hydrant valve, cleared the sediment, and returned the valve to service. PSCO conducted test of the fire main with satisfactory results. 10c
Action required: 705 - Other - as specified
Resolved 1 February 2010
Resolution: Crew removed hydrant valve, cleared the sediment, and returned the valve to service. PSCO conducted test of the fire main with satisfactory results.
Fire Fighting › Fire Main › Condition
Issued 1 February 2010
Resolved
While conducting a test of the fire main, PSCO identified a hole in the fire main aft of the house on the port side Upper deck. Pressure of the fire system was not effected. Ship's crew completed temporary repairs, permanent repairs to be completed prior to next U.S. port after sailing foreign to the satisfaction of Class. 70ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 March 2010
Resolution: 01 MAR 2010----Received Class report stating that the holed Fire main pipe was partly renewed and tested to the satisfaction of Class.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 March 2009
Resolved
0745 Manual fire dampers for ventilation throughout engine room are inoperable rendering fire safety measures ineffective. Class is to verify manual fire dampers throughout the engine room are in good working order
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2009
Resolved 2 April 2009
Resolution: Received class report.
Fire Fighting › Portable Foam Applicators › General
Issued 9 March 2009
Resolved
0720 20 liter portable foam applicator tanks next to engine casing are leaking. Portable foam applicator would not be able to effectively fight a fire. Portable foam throughout the vessel should be inspected to the satisfaction of class
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2009
Resolved 2 April 2009
Resolution: Received class report.
Fire Fighting › Fire Main › Condition
Issued 14 October 2007
Resolved
PIN-HOLE LEAK IN FIRE MAIN LOCATED ON EXTERIOR MAIN DECK FORWARD OF NAV BRIDGE. DISCOVERED DURING TEST OF EMERGENCY FIRE PUMP. SATISFACTORY FIREMAIN PRESSURE OBSERVED DURING TEST- FIREFIGHTING & LIFESAVING CAPABILITY NOT COMPROMISED. MUST RECTIFY DEFICIENCY PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN TO SATISFACTION OF CLASS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 October 2007
Resolution: rcvd class report
Electrical › Electric Supply System (service) › Transformer
Issued 3 April 2006
Resolved
Rubber matting missing in front of several electrical panels creating shock hazard throughout engine room .
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 19 June 2006
Resolution: Received class report verifying repairs.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 3 April 2006
Resolved
All pressure and temperature gauges on all three diesel generators are inoperable. Also, sight glass on steam boiler is cracked and leaking.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 19 June 2006
Resolution: Received class report verifying repairs.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 3 April 2006
Resolved
Fire control plan (FCP) is inaccurate in way of class " A" Division not indicated between galley and officer mess, galley and crew mess. Also, bulkheads on FCP between officer mess/officer lounge and crew mess/ crew lounge running in wrong direction with no doorway.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 19 June 2006
Resolution: Received class report verifying repairs.
Fire Fighting › Structural - A Class Divisions
Issued 7 March 2003
Resolved
Fire doors located on the 8th deck, 9th deck, and 10th deck were not able to close sufficiently or were blocked with items that would not allow them to be opened. Temporary repairs were made while on board. Vessel is required to make permanent repairs to the satisfaction of Class. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 January 2004
Resolved 7 February 2004
Resolution: Repairs carried out to the satisfation of the Classification Society. Report filed to MSO San Juan.
Fire Fighting › Portable Foam Applicators
Issued 7 March 2003
Resolved
Foam applicator storage boxes were missing fire hoses as required by their inventory list. Master disputes need for hoses at foam stations. Resolve to satisfaction of Flag Administration at next Flag State inspection or Class Society survey.
Action required: 705 - Other - as specified
Due 1 January 2004
Resolved 7 February 2004
Resolution: Corrected to the satisfaction of Class Society. Report filed to MSO San Jaun.
Construction/Loadline › Markings
Issued 9 November 2002
Resolved
LOADLINE STBD SIDE NEEDS PAINTING. ICLL66 LEGACY COMPONENT DESC: Load Line Mark
Due 9 December 2002
Resolved 7 March 2003
Engineering › Sea-water System (primary cooling)
Issued 9 November 2002
Resolved
SALT WATER COOLING LINE FOR MAIN ENGINES STBD LOWER ENGINE ROOM, TEMP REPAIRS WERE EFFECTED TODAY. PERMANENT REPAIRS TO BE EFFECTED TO THE SATISFACTION OF CLASS. SOLAS 74 II-1/263 LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 9 December 2002
Resolved 7 March 2003
Engineering › Freshwater System (air cooling) › Piping
Issued 9 November 2002
Resolved
AIR COOLER CHEMICAL CLEANING PUMP. TEMPORARY PIPING REMOVED FROM PUMP DIRECTLY TO SEWAGE TANK. LINE NOT IN SERVICE. MARPOL 73/78
Due 9 November 2002
Resolved 9 November 2002
Resolution: PIPING HAS BEEN REMOVED.
Engineering › Lubricating Oil Service System
Issued 9 November 2002
Resolved
FIXED MECHANICAL SEALS FOR NO. I HFO BOOSTER PUMP FOR MAIN ENGINE LEAKING AT A RATE OF 1 DROP PER SEC. SOLAS 74/78 II-1/26 LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 9 December 2002
Resolved 7 March 2003
Engineering › Compressed Air System (control)
Issued 9 November 2002
Resolved
EFFECT REPAIRS TO SIGHT GLASS NO.1 MAIN COMPRESSOR FRESH WATER COOLING LINE. SOLAS 74/78 II-1/26.
Due 9 December 2002
Resolved 7 March 2003
Electrical
Issued 9 November 2002
Resolved
NON- CONDUCTIVE MATS NOT LOCATED AT ELECTRICAL SWITCHBOADS IN MAIN MACHINERY SPACE. SOLAS 74/78/II-1/45. LEGACY COMPONENT DESC: NON CONDUCTIVE MATS
Due 9 December 2002
Resolved 7 March 2003
Construction/Loadline › Hull
Issued 19 June 2002
Resolved
CLASS SURVEYOR TO ATTEST TO TEMPORARY REPAIRS MADE TO INSETS LOCATED ON STBD QUARTER, PROVIDE REPAIR PROPOSAL FOR THE SAME. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 5 September 2002
Resolution: RECEIVED FAX FROM CLASS INDICATING THAT REPAIRS WERE MADE FROM DEF ISSUED IN REFERENCE RE-EXAM CONDUCTED ON 19JUN02. DEF CLEARED.
Accommodation/Occupational Safety
Issued 13 October 2001
Resolved
Provide faxed food reciept for food stores receiving in New York._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 13 October 2001
Resolved 9 November 2002
Resolution: ADEQUATE FOOD FOR VOYAGE ONBOARD
Electrical
Issued 7 August 2000
Resolved
EMERGENCY GENERATOR NOT ABLE TO START/ NOT READY FOR IMMEDIATE USE. CLEAREDWHILE ON BOARD.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Fire Fighting
Issued 7 August 2000
Resolved
SEMI-PORTABLE FIRE EXTINGUISHER I.W.O. BOILER CASING HAD WORN/DETERIORATED HOSE. REPLACE HOSE TO THE SATISFACTION OF CLASS NO LATER THAN 07SEP00 OR PRIOR TO NEXT U.S. VISIT.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Engineering
Issued 7 August 2000
Resolved
NUMEROUS LEAKS AND OIL-SOAKED LAGGING ON GENERATOR LUBE OIL PIPING AND FITTINGS. STOP/CORRECT LEAKS, CLEAN UP AREA, REPLACE LAGGING PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 7 August 2000
Resolved
DOOR TO EMERGENCY GENERATOR SPACE CONSTRUCTED WITH IMPROPER MATERIAL (WOOD). INSTALL STEEL OR EQUIVALENT DOOR IN SPACE AT NEXT AVAILABLE DRYDOCKTO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Engineering
Issued 7 August 2000
Resolved
NUMEROUS LEAKS AND OIL-SOAKED LAGGING ON MAIN FUEL OIL TRANSFER PUMPS AND PIPES. STOP/CORRECT LEAKS,CLEAN UP SPACE, AND REPLACE LAGGING PRIOR TO NEXTU.S. PORT.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 7 August 2000
Resolved
PORTABLE (WHEELED) FIRE EXTINGUISHER IN GENERATOR SPACE NOT MOUNTED/SECUREDPROPERLY. (TIED WITH LINE TO LADDER) ITEM CLEARED ON BOARD. A BRACKET WAS MOUNTED TO HOLD PORTABLE UNIT IN PLACE.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Fire Fighting
Issued 7 August 2000
Resolved
FIRE BOUNDARY IN EMERGENCY GENERATOR SPACE IMPROPER CLASS FOR SPACE (B CLASS BOUNDARY INSTALLED; CLASS A BOUNDARY REQUIRED.) INSTALL CLASS A FIRE BOUNDARY TO THE SATISFACTION OF CLASS SOCIETY, AT NEXT AVAILABLE DRYDOCK.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Construction/Loadline
Issued 7 August 2000
Resolved
BILGE PUMPS UNABLE TO TAKE SUCTION. PUMPS WERE AIR BLOCKED. ITEM WAS CORRECTED ON BOARD.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Engineering
Issued 2 July 1999
Resolved
Remove temporary patch and make permanent repair to main engine S/W_x001C_ cooling line at lower flat, stbd side E/R. Provide class report attesting to proper repair. Correct prior to next U.S. port after sailing foreign._x001C_ SOLAS 74 amd Chap. I/11
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Navigation
Issued 15 June 1995
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH CHARTS #12333, 12326, AND 12327 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 15 June 1995
Resolved 26 June 1995