Records from 2013 to 2026. Most recent: inspection, 11 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 32
11 June 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8400958
27 May 2026
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8381659
25 November 2025
Damage Survey · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8275629
27 July 2025
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8214310
20 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8141299
30 January 2025
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8072688
10 October 2024
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8029066
13 June 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7934106
5 April 2024
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7890427
13 February 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7865069
10 July 2023
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7825890
18 April 2023
SIP Inspection/Audit · Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7672227
14 April 2023
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7668520
16 September 2022
Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7560373
30 March 2022
Administrative Inspection · SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7421519
13 July 2021
Administrative Inspection · SIP Inspection/Audit · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7254876
28 June 2021
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7239200
1 July 2020
Annual Inspection · SIP Inspection/Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6992816
18 June 2020
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6983511
28 May 2020
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6962351
13 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6926127
1 December 2019
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6876062
13 August 2019
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6794901
14 May 2019
SIP Inspection/Audit · MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6683615
8 March 2019
Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6639922
16 November 2018
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6582116
21 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6561361
7 May 2018
Annual Inspection · SIP Inspection/Audit · MTSA/ISPS Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6410299
15 May 2017
DAPI Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6152274
5 April 2017
Deficiency Check · COI Inspection · SIP Initial Entry
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6119569
10 August 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5969217
18 May 2016
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5881193
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2026
Resolved
Fourteen children life jackets were found without required labels, reflective tape. In addition, a number of child-size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section. Provide fourteen child size life jackets to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 11 June 2026
Resolution: Resolved on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2026
Resolved
It could not be determined that two fire hose nozzle were in compliance with regulations. Have fittings of brass or other suitable corrosion-resistant material that comply with National Fire Protection Association (NFPA) 1963 “Fire Hose Connections,” or other standard specified by the Commandant. Provide verification nozzles are in compliance with regulations to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 24 June 2026
Resolution: MI verified brass nozzel installed all stations.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 June 2026
Resolved
Fire pump strainer leaks and is reducing fire pump prime. A self priming, power driven fire pump must be installed on each vessel. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 24 June 2026
Resolution: New Strainer purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2026
Resolved
Heater and junction box in storage compartment is loose and is a safety hazard. Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions. Make repairs or remove to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 24 June 2026
Resolution: Heater removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2026
Resolved
3 screws missing from electric panel front cover. Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions. Make repairs or remove to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 24 June 2026
Resolution: Three screws installed.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 13 June 2024
Resolved
It was identified during the fire drill in the engine room that the handle to shore tie breaker was broken off. The captain was using an alternate method to shift power that was unsafe. It was also noted the SIP correction report had not been created/logged when the deficiency was identified by the crew. Electrical equipment on a vessel must be installed and maintained to provide service necessary for safety under normal and emergency conditions. Have electrician service the panel before shifting to shore power that could will lead to the improper operation of the switchboard. Conduct repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 17 June 2024
Resolution: Received objective evidence the breaker was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2024
Resolved
Anti freeze coolant was found in bilge under both port and starboard keel coolers that indicate a possible leak. All engines must be water cooled and meet the requirements in 46 CFR 119.420. Identify source of coolant leak and provide a repair proposal to the satisfaction of he attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 21 June 2024
Resolution: Received objective evidence SIP manager that the coolant was cleaned and no further leaking was found.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 June 2024
Resolved
Oil leaks were found on port and starboard generator prime movers. Auxiliary machinery of the internal combustion piston type must comply with the provisions of 46 CFR 119.310. Identify source of leak and provide a repair proposal to the satisfaction of he attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 17 October 2024
Resolution: Oil leaks were rectified.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 5 April 2024
Resolved
River Queen Captain report AIS malfuction. AIS fail to transmit signal. Failure to have a operational AIS on board. Prove proper opertation to the attending USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2024
Resolved 15 April 2024
Resolution: Verified AIS was operational
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 April 2023
Resolved
During administrative inspection it was identified the EAP 46 CFR 16.401 policy/statement, hotline phone number and compliance documentation requirements were not posted. The requirement were not available in the SIP ICR program and have not been inspected since SIP inception. Post EAP policy/statement, hotline phone number and add an ICR to SIP program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 11 July 2023
Resolution: EAP policy/statement, hotline phone number were posted on vessel and add an ICR to SIP program was created.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 April 2023
Resolved
Three emergency escape hatches provided for the crews to egress out of the engine room in the event of an emergency were blocked preventing the crews safe evacuation. Each door hatch or scuttle used as a means of escape must be capable of being operated by one person from either side. Deficiency was rectified at the time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 18 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 April 2023
Resolved
Auxiliary space forward of the engine room is missing 8'x 15' of of structural insulation above the sewage tank. Bulkhead and decks of the A class shall be composed of steel or equivalent metal construction. In addition they shall be so insulated with approved structural insulation that the average temperature on the unexposed side would not rise more than 250 F above the original temperature nor would the temperature at any point, including any joint, rise more than 325 F above the original temperature within the time A-60 or minutes. Install approved structural insulation in auxiliary space to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 11 July 2023
Resolution: Approved insulation installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023
Resolved
Light in auxiliary space has become disconnected from its mounts and is dangling from the overhead creating a potential electrical hazard if the light were to disconnected from the wiring. All electrical installations shall be to the satisfaction of the Officer in Charge Marine Inspections. Conduct repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 11 July 2023
Resolution: Light was repaired and was mounted to overhead.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 April 2023
Resolved
Auxiliary space forward of engine room does not have a suitable means to shut off air to the space in the event of a fire. In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire. Provide proposal to manufacture a means to close off air in the event of a fire to the axillary space forward of engine room to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2023
Resolved 11 July 2023
Resolution: Dampers installed with fusable link.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2022
Resolved
Vessel sustained damage to engine cooling system. Cummings Diesel technician diagnosed issue as cylinder jacket breach. Engine must be repaired to full operability.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 14 April 2023
Resolution: Received Cummins tech report scanned into documnets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2021
Resolved
The door on the switchboard in engine room will not shut entirely. Door locks but top is not seating properly leaving a gap open at top and bottom corner. Electrical equipment used in the following locations must be drip proof. Repair or replace switchboard door so that it in seating properly at all corners of switchboard to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 16 August 2021
Resolution: Electrician repaired switchboard door so that it opens and closes properly without aid of straps. Interlock moved freely and MI observed each breaker turned on and off without opening door.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2021
Resolved
Battery charger for main engine start is plugged into a 110 outlet leaving the potential for equipment to be unplugged or vibrated loose. Electrical equipment and installation must be suitable for the roll, pitch and vibration of the vessel underway. Permanently install/Hard wire battery charger into approved enclosure to the satisfaction of the attending Coast Guard Marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2021
Resolved 16 August 2021
Resolution: Battery charger was hard wired in.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 July 2020
Resolved
E-light on second deck battery had failed. Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck.
The emergency lighting required of this section must automatically actuate upon failure of the main lighting system. If a vessel is not equipped with a single source of power for emergency lighting, it must have individual battery powered lights. Install new battery to so that the e-light automatically light when there is a loss of power to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 15 - Rectify deficiencies by next port
Due 1 July 2020
Resolved 1 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 May 2019
Resolved
Engine Room- The two required means of escape must be widely seperated and, if possible, at opposite ends or sides of the space to minimize the possibility of one incident blocking both escapes.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
Resolution: Removed obstruction from on top escape hatch. Hung sign designating area as emergency escape hatch.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 March 2019
Resolved
Crop and renew #7 vent box on port side main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 March 2019
Resolved
Make starboard side, main deck engine room vent box water tight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 March 2019
Resolved
Make watertight bulkhead between storage space and potable water space watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Adjusted alignment.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 March 2019
Resolved
Prove watertight integrity of all watertight doors, hatches, and scuttles.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Examined SIP records of tests conducted on 08AUG2018.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2019
Resolved
Remove portable dehumidifier in potable water space or make permanent installation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 March 2019
Resolved
Crop and renew wasted area of vertical deck support on starboard side, aft, between upper deck and 2nd deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Repaired to original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2019
Resolved
The reach-rod in the forward compartment has seized up. Renew to original.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2019
Resolution: Cleaned, oiled and removed rust.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2018
Resolved
46 CFR 15.725 permits the Master to sail short, provided he or she determines the vessel is sufficiently manned for the voyage. However, it also requires that the Master must file a report of sailing short to the OCMI having cognizance for inspection in the area which the vessel is operating within 12 hours.
Action required: 10 - Deficiency Rectified
Due 21 September 2018
Resolved 5 October 2018
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 April 2017
Resolved
Due to the river conditions, a man overboard drill and fire drill were not
conducted during your vessel’s COI. Please schedule a follow up with
this office prior to the due date.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 30 May 2017
Engineering › Fuel Oil Service System › Piping
Issued 18 May 2016
Resolved
Residual oil has accumulated on fuel injector lines on both generators and main engines, and turbo on port main engine has accumulated debris; make proper clean-up to ensure removal; make proper clean-up of lines to ensure removal fire hazard to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 11 August 2016
Resolution: See Attached documents.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 May 2016
Resolved
Certificate of Documentation was not onboard; place current COD onboard vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 11 August 2016
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 May 2016
Resolved
Identified leak in aft fuel tank space, port side; inspection port bolts tightented, corrected on the spot.
Condition: Improper Installation
Due 18 May 2016
Resolved 18 May 2016
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 18 May 2016
Resolved
Identified several 6 lifejackets that required new retroflective tape and/or re-labeling of vessel name; corrected on the spot.
Condition: Improper/Lack of Maintenance
Due 18 May 2016
Resolved 18 May 2016
Resolution: Corrected on the spot.