BELLE OF CINCINNATI

BELLE OF CINCINNATI is a 1991 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 2016, most recently in June 2026, along with 30 deficiencies and 11 casualty investigations between 2004 and 2026.

Records from 2004 to 2026. Most recent: inspection, 24 June 2026.

Built
1991
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF5294
359141
Flag
UNITED STATES
Maury page id
psix-359141

Documentation record

Registered dimensions (L × B × D)172.8 ft × 46.4 ft × 11.1 ft
Registered tonnagegross 1,168 / net 881
ITC dimensions (L × B × D)172.8 ft × 46.4 ft × 11.1 ft
ITC tonnagegross 1,663 / net 590
BuilderATLANTIC MARINE INC · JACKSONVILLE, FL, UNITED STATES · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCINCINNATI, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1168 - Regulatory (Subpart C or D), Gross Ton
1663 - Convention (Subpart B), Gross Ton
881 - Regulatory (Subpart C or D), Net Ton
590 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RIVER QUEEN Passenger (Inspected) · MISLE 280066 · 13 August 2019 · activity 6794901

Inspection history · 55

24 June 2026 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8413513
22 May 2026 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8381558
18 May 2026 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8382459
3 April 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8341537
26 March 2026 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8332843
26 March 2026 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8338620
4 March 2026 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8319635
17 December 2025 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8284777
6 November 2025 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8268409
12 August 2025 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8209258
16 June 2025 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8264656
29 May 2025 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8149641
6 March 2025 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8088602
21 January 2025 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8067355
10 October 2024 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8028102
18 September 2024 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8028072
27 July 2024 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7968290
11 June 2024 SIP Inspection/Audit · Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7934765
23 May 2024 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7941578
5 March 2024 Administrative Inspection · COI Inspection · SIP Inspection/Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7873821
13 February 2024 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7865390
7 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7821675
6 March 2023 SIP Inspection/Audit · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7647533
5 January 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7617308
3 August 2022 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7525297
18 July 2022 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7512641
6 June 2022 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7470231
8 May 2022 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7446795
15 March 2022 SIP Inspection/Audit · Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7412709
18 January 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7382025
22 June 2021 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7232843
19 May 2021 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7201100
3 February 2021 SIP Inspection/Audit · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7134568
29 October 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7086567
18 September 2020 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7072251
4 September 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7049946
5 August 2020 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7026513
1 August 2020 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7043895
28 May 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6962322
4 February 2020 Deficiency Check · Administrative Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6902175
16 September 2019 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6815915
15 September 2019 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6831529
13 August 2019 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6794901
25 July 2019 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6791373
5 February 2019 Administrative Inspection · COI Inspection · Deficiency Check · SIP Inspection/Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6620414
2 February 2018 COI Inspection · Administrative Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6347553
7 November 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6304067
15 May 2017 DAPI Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6152260
10 May 2017 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6146604
30 January 2017 SIP Inspection/Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6078294
18 October 2016 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6025185
12 September 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6009636
5 February 2016 COI Inspection · Deficiency Check · SIP Inspection/Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5808249
22 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5801677
5 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5801898

Deficiency record · 30

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026 Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 20 July 2026
Resolution: Received objective evidence matting put in front and rear of switchboard. Photos added to deficiency documents.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 March 2026 Resolved
Watertight integrity of vessel hull has been compromised. Vessel has active flooding in the bow thruster compartment coming from underneath an existing hole that was being contained by a temporary concrete patch. A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel shall proceed to drydock for permanent repairs. Owner shall provide transit plan for approval prior to departure. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2026
Resolution: Inspected repairs. Tested welds. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2025 Resolved
Starboard generator had coolant leak. All installations shall be of marine type engine suitable for the intended service. Make repairs to the satisfaction of the attending Coast Guard marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2025
Resolution: Gasket repaired. Received correction report from [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2025 Resolved
The reverse power relay failed during and test. Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2025
Resolved 18 May 2026
Resolution: 00 Def’s Issued, 00 Def’s Outstanding, 00 Def’s rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2025 Resolved
Port and starboard generators over speed failed during annual test. The control system shall be designed for automatic shutdown of the engine with the actuation of audible and visual alarms for over speed. Make reapirs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2025
Resolved 10 February 2026
Resolution: Observed overspeed on both generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2025 Resolved
Port generator failed low lube oil pressure during annual test. The control system shall be designed for automatic shutdown of the engine with the actuation of audible and visual alarms for over speed. Make repairs to the satisfaction of the attending Coast Guard marine
Action required: 15 - Rectify deficiencies by next port
Due 31 December 2025
Resolved 10 February 2026
Resolution: Observed low lube oil pressure alarm.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 29 May 2025 Resolved
During SIP Audit/ Inspection - witnessed crewmember perform ICR inspection P 05 G. Noted control panel cover screws on top of panel. When panel was opened, found wires disconnected from one of the breakers. Crewmember was unaware of loose wires before preforming inspection. SIP rep stated the chief had Carrier working on system. System was not tagged out, required rep to have system tagged out.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 30 May 2025
Resolution: Received objective evidence the system was tagged out.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2025 Resolved
While witnessing crewmember perform ICR P-05 paragraph G. it was noted that wires were disconnected from one of the breakers inside the A/C control panel. Company is NOT following Safety Program procedures for log out tag out. Review procedure and provide training to ALL personnel.
Action required: 705 - Other - as specified
Due 29 August 2025
Resolved 28 July 2025
Resolution: Received objective evidence that training was conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2025 Resolved
During SIP Audit/ Inspection - witnessed crewmember perform ICR inspection J-02 B. 1. Noted that the warmers on wheels and are unsecured and stationed near their deep fat fryers presenting a hazard. The electrical cables from the warmers are touching the handrails to the ladder coming into the space creating a potential electrical hazard if there were a short. Move warmers and plugs to a less hazardous location and properly secure warmers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 16 July 2025
Resolution: Verified warmers were moved into a safe location.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 March 2025 Resolved
Marine Inspector recognized the conditions of the concrete box patch in thruster tunnel to have changed. After further investigation, it was revealed that the temporary concrete patch was removed due to an ineffective installation and the vessel was intentionally beached on a sandy bottom and the crew installed a new box patch. The event was not logged, the repair was not indicated in the SIP correction report. SIP 2-99: Correction Reports become part of the company’s reporting mechanism and can be instrumental in identifying and correcting recurring problems with the vessel systems and subsystems. 46CFR71.55-1(a): No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery or equipment shall be made without the knowledge of the Officer in Charge, Marine Inspections. Multiple failures in the records keeping and deficiency reporting of structural watertight integrity company shall conduct training for the company SIP agent who is responsible for the implementation for the Vessel Action Plan. daily inspection records of the affected space shall be maintained that specifies water level and daily pump out. If any changes to the space occurs master shall contact the Officer in Charge Marine Inspections
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 19 May 2025
Resolution: BB Riverboats conducted training for the company SIP agent who is responsible for the implementation for the Vessel Action Plan. Daily inspection records of the affected space established 6March2025.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2024 Resolved
Vessel Rep could only provide three months of logbook entries. The master or person in charge of a vessel that is not required by 46 U.S.C. 11301 to have an official logbook, shall maintain, on board, an unofficial logbook or record in any form desired for the purposes of making entries therein as required by law or regulations in this subchapter. logs must be kept available for review by a marine inspector for a period of 1 year after the date to which the records refer. Maintain logbook records for a total of 1 year for inspection for review by a marine inspector to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 November 2023 Resolved
Vessel galley has a griddle and deep fryer fixed fire fire fighting system. Once the the fixed fire fighting system is activated the ventilation shall automatically stop the ventilation. During fire drill it was discovered that the ventilation shutdown was not working for all fans. Exhaust for galleys shall meet the applicable bulkhead requirements. In addition an automatic damper shall be installed in exhaust ducks over frying vats ect. Make repairs to the fixed fire fighting automatic ventilation shutdown in the galley. To the satisfaction of the attending Coast Guard Marine Inspector. Do not use deep fat fryer and griddle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 12 December 2023
Resolution: Comducted test of emergency ventilation shutdown with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 November 2023 Resolved
Galley ventilation above deep fat fryer and griddle had excessive grease buildup and lent that is at risk for fire. The general construction of the vessel shall be such as to minimize fire hazards. Clean ventilation above deep fat fryer and griddle to the satisfaction of the attending Coast Guard marine
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 12 December 2023
Resolution: Venilation was cleaned.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 November 2023 Resolved
Watertight door handle in the galley is coming into contact with an electrical panel cover which has partially broke free from bulkhead. If the electrical panel cover come completely out from bulkhead it will impede the WTD handle and prevent the door from closing in the event of a fire or flooding. The general construction of the vessel shall be such as to minimize fire hazards. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 12 December 2023
Resolution: Electrical panel secured to bulkhead.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 November 2023 Resolved
An extension cord supplying a freezer was handing over the top of the galley fryer vat creating a fire hazard. The general construction of the vessel shall be such as to minimize fire hazards. Remove extension cord over fryer vat to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 7 November 2023
Resolution: Extension cord was removed during inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 January 2023 Resolved
Vessel fixed fire fighting halon agent was accidentally discharged by Silco fire and security during test of the system leaving the engine room without a fixed fighting system. The company is waiting for a replacement bottle. An approved extinguishing system must be installed as required by table 76.05-1 on all self propelled vessels. Vessel shall not operate engine room machinery until fixed fire fighting system is repaired. Rectify deficiencies prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2023
Resolution: Conducted system test with satisfactory results. New bottle of Halon intsalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 August 2022 Resolved
Solenoid valve for generator failed.
Action required: 10 - Deficiency Rectified
Due 3 August 2022
Resolved 3 August 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 March 2022 Resolved
Vessel representative could not provide training form (B&B Riverboats Marine Employee Training System Employee Log) that is used to track employees training which is compulsory in the company action plan. The crew must be instructed in the use of the vessel's fire-extinguishing and lifesaving appliances and in survival at sea at the same interval as the drills. Individual units of instruction may cover different parts of the vessel's lifesaving and fire-extinguishing appliances, but all the vessel's lifesaving and fire-extinguishing appliances must be covered within any period of 2 months. n2-99 track and record training for individual employees, and the training required for the designated SIP support personnel to implement the CAP and the VAP. Provide marine employee training records in accordance with B&B Riverboats Company Action plan and vessel action plan to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 25 April 2022
Resolution: Received objective evidence crew training and audit
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2021 Resolved
Exit sign on first deck did not illuminate. Illumination exit signs are required and must be installed in accordance with Subchapter J. Repair exit sign to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 26 February 2021
Resolution: Exit sign repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2021 Resolved
Thirteen emergency light bulbs were extinguished or missing from the pilot house down to the first deck. Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide safe egress from the space. Repair/renew all extinguished or missing emergency lights to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 26 February 2021
Resolution: E light bulbs replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2021 Resolved
MI identified two wasted life jackets in rescue boat. Life jackets must meet approval requirements of 46 CFR1 199.70 Replace wasted life jackets to the satisfaction of the attending Coast Guard inspector.
Action required: 10 - Deficiency Rectified
Due 3 February 2021
Resolved 3 February 2021
Resolution: Two new PFDs replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 February 2021 Resolved
ICR A-02 of the companies SIP states that the notice to mariners are onboard for the intended operating area. The marine inspector noted no notice to mariner were onboard the vessel. Licensed deck officers are required to acquaint themselves with the latest information published by the Coast Guard and the National Geospatial-Intelligence Agency regarding aids to navigation. Neglect to do so is evidence of neglect of duty. It is desirable that all vessels have available in the pilothouse for convenient reference at all times a file of the applicable Notice to Mariners. Implement ICR A-02 of the companies SIP and provide notice to mariner for the intended operating area to the satisfaction of the Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 26 February 2021
Resolution: NTM were placed in the pilot house.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 August 2020 Resolved
Owner reported a failure of the battery charger for the ships service generator that subsequently reduced power for vessel and loss of steering pump. Operating generators must provide a continuous and uninterrupted source of power for this ships service under normal operational conditions. Conduct repairs to the battery charger for the ships service generator to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 5 August 2020
Resolved 5 August 2020
Resolution: Owner issued correction report verifying system was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2020 Resolved
During man overboard drill the Belle of Cincinnati's rescue boat engine stalled while underway and failed to start again. Each passenger vessel of less than 500gt must carry one rescue boat. Conduct repairs or replace rescue boat engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 19 February 2020
Resolution: Owner purchased and installed new small boat engine.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2020 Resolved
Rescue boat fire extinguisher was not in its bracket and had expired. Each passenger vessel of less than 500gt must carry at least one rescue boat that is equipped in table 199.175 of this part. Replace fire extinguisher and mount in fire extinguisher bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 19 February 2020
Resolution: MI observed new fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 February 2020 Resolved
During fire drill, two fire stations, one forward and second deck and the other located in the engine room, charged at the fire station while not in use. The outlet at each fire hydrant must be provided with a cock or valve fitted in such a position that the firehose may be removed while the fire main is under pressure. Conduct maintenance on the fire stations so that the fire station does not charge while not in use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 19 February 2020
Resolution: New gate valves were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 September 2019 Resolved
Affect repairs as necessary to ensure that oil is not discharged into the navigable waters of the U.S. via the vessel's port main diesel generator exhaust and/or effluent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 18 September 2020
Resolution: Owner satisfactory installed load bank.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 February 2019 Resolved
Hydrostatic release on Buoyant Appartus expired.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 March 2019
Resolved 6 March 2019
Resolution: Replaced hydrostatic release.
Electrical › Electric Generation Source (emergency) › Generator
Issued 5 February 2016 Resolved
Emergency generator low lub oil shut off not functioning.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2016
Communications › Audible Communications › Horn/Whistle
Issued 5 January 2016 Resolved
Horns removed for service. Temporarily being replaced by a supplemental air horn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 13 May 2016

Casualty record · 11

7 July 2004Routine · role: Involved in a Marine Casualty · activity 2138135
29 September 2006Routine · role: Involved in a Marine Casualty · activity 2795555
29 October 2010Routine · role: Involved in a Marine Casualty · activity 3881128
23 March 2012Routine · role: Involved in a Marine Casualty · activity 4283600
25 October 2012Routine · role: Involved in a Marine Casualty · activity 4548857
16 November 2012Routine · role: Involved in a Marine Casualty · activity 4549524
11 December 2014Routine · role: Involved in a Marine Casualty · activity 5038295
13 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6794901
1 August 2020Routine · role: Involved in a Marine Casualty · activity 7043895
8 May 2022Routine · role: Involved in a Marine Casualty · activity 7446795
26 March 2026Routine · role: Involved in a Marine Casualty · activity 8338620
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.