BELLE OF CINCINNATI

BELLE OF CINCINNATI is a 1991 passenger vessel (inspected). The Coast Guard has recorded 175 inspections since 1991, most recently in June 2026, along with 134 deficiencies and 11 casualty investigations between 2004 and 2026.

Records from 1991 to 2026. Most recent: inspection, 24 June 2026.

Built
1991
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF5294
359141
Flag
UNITED STATES
367461550
Maury page id
psix-359141

Inspections, by type

…with no type recorded39
Years with a record 32 calendar years (1991–2026)
The 175 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)172.8 ft × 46.4 ft × 11.1 ft
Registered tonnagegross 1,168 / net 881
ITC dimensions (L × B × D)172.8 ft × 46.4 ft × 11.1 ft
ITC tonnagegross 1,663 / net 590
BuilderATLANTIC MARINE INC · JACKSONVILLE, FL, UNITED STATES · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCINCINNATI, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1168 - Regulatory (Subpart C or D), Gross Ton
1663 - Convention (Subpart B), Gross Ton
881 - Regulatory (Subpart C or D), Net Ton
590 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF5294MMSI 367461550 · active · compulsorily equipped · granted 22 May 2020, expires 22 July 2030
WAR6753MMSI not assigned · expired · compulsorily equipped · granted 8 December 1995, cancelled 6 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RIVER QUEEN Passenger (Inspected) · MISLE 280066 · 13 August 2019 · activity 6794901

Inspection history · 175

24 June 2026 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8413513
22 May 2026 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8381558
18 May 2026 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8382459
3 April 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8341537
26 March 2026 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8332843
26 March 2026 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8338620
4 March 2026 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8319635
17 December 2025 Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8284777
6 November 2025 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8268409
12 August 2025 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8209258
16 June 2025 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8264656
29 May 2025 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8149641
6 March 2025 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8088602
21 January 2025 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8067355
10 October 2024 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8028102
18 September 2024 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8028072
27 July 2024 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7968290
11 June 2024 SIP Inspection/Audit · Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7934765
23 May 2024 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7941578
5 March 2024 Administrative Inspection · COI Inspection · SIP Inspection/Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7873821
13 February 2024 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7865390
7 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7821675
6 March 2023 SIP Inspection/Audit · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7647533
5 January 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7617308
3 August 2022 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7525297
18 July 2022 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7512641
6 June 2022 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7470231
8 May 2022 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7446795
15 March 2022 SIP Inspection/Audit · Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7412709
18 January 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7382025
22 June 2021 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7232843
19 May 2021 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7201100
3 February 2021 SIP Inspection/Audit · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7134568
29 October 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7086567
18 September 2020 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7072251
4 September 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7049946
5 August 2020 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7026513
1 August 2020 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7043895
28 May 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6962322
4 February 2020 Deficiency Check · Administrative Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6902175
16 September 2019 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6815915
15 September 2019 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6831529
13 August 2019 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6794901
25 July 2019 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6791373
5 February 2019 Administrative Inspection · COI Inspection · Deficiency Check · SIP Inspection/Audit
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6620414
2 February 2018 COI Inspection · Administrative Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6347553
7 November 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6304067
15 May 2017 DAPI Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6152260
10 May 2017 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6146604
30 January 2017 SIP Inspection/Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6078294
18 October 2016 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6025185
12 September 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6009636
5 February 2016 COI Inspection · Deficiency Check · SIP Inspection/Audit · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5808249
22 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5801677
5 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5801898
15 December 2015 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5785609
21 July 2015 Excursion Permit · Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5192189
22 June 2014 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4974192
28 May 2014 SIP Inspection/Audit · Periodic Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4857177
6 May 2014 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4851450
22 July 2012 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4387591
16 July 2012 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4384914
8 February 2012 COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4224136
14 December 2011 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4206270
8 February 2011 COI Inspection · DAPI Audit · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3940412
29 October 2010 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3881128
8 February 2010 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3676041
22 July 2009 Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3547391
5 February 2009 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3412212
20 May 2008 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3211630
5 February 2008 COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3142022
9 November 2007 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3096992
27 July 2007 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3022278
2 July 2007 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2980873
27 February 2007 SIP Inspection/Audit
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2878675
23 February 2007 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2876353
30 September 2006 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2802341
29 September 2006 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2795555
24 February 2006 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2593980
1 February 2006 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2576272
15 November 2005 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2564715
25 February 2005 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2297906
9 February 2005 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2287783
27 October 2004 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2233182
7 July 2004 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2138135
26 May 2004 Administrative Inspection · Excursion Permit
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2078962
21 May 2004 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2137873
10 May 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2063666
28 April 2004 Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2055213
19 April 2004 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2047907
5 April 2004 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2037790
28 January 2004 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1995003
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970960
26 November 2003 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1954770
24 October 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1943623
29 September 2003 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1916636
6 August 2003 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1868561
27 February 2003 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1750163
21 January 2003 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1736928
9 October 2002 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1695346
18 September 2002 SIP Initial Entry
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2878672
21 June 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1635448
9 April 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1602923
21 February 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1490739
10 December 2001 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1391739
5 December 2001 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1444655
6 September 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1471624
7 June 2001 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1065959
23 May 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1456995
30 April 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1064188
19 April 2001 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1061768
9 April 2001 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1061952
3 March 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 74565
27 February 2001 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1461398
5 September 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 824735
22 August 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1379238
4 August 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1053786
26 May 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 104364
23 May 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1361589
16 May 2000 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1049898
5 May 2000 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1049740
24 April 2000 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 817618
3 April 2000 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1047768
23 March 2000 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1386764
22 February 2000 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1418670
30 December 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1458740
18 November 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1440220
16 November 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 808501
20 October 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1365425
19 October 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 801146
8 October 1999 Re-Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1372816
2 September 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1445538
31 August 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1116652
3 August 1999 Deadweight Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1111227
31 July 1999 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1438928
28 July 1999 Excursion Permit · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1458660
16 July 1999 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 20961
2 July 1999 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384131
17 November 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439609
12 April 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355457
25 May 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861394
23 March 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165737
6 January 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 852790
19 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157821
28 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154082
12 April 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 833855
25 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1133098
2 February 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149030
2 February 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149402
2 February 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1152102
11 January 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1136359
2 December 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962830
24 November 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1140001
21 August 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1268362
29 July 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263048
25 June 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 962638
17 June 1992 Deficiency Check · Sanitary Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 949869
7 May 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1357946
1 May 1992 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 962615
15 April 1992 Deficiency Check · Sanitary Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 955377
21 February 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1456050
22 January 1992 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 950562
11 December 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1256328
5 December 1991 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1472569
24 October 1991 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 937902
19 September 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1246568
9 September 1991 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1246319
11 August 1991 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 85501
24 July 1991 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 168335
16 July 1991 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 32878
25 May 1991 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 47407
21 May 1991 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 39133
20 May 1991 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2338
9 May 1991 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224638
26 January 1991 Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1224954

Deficiency record · 134

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026 Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 20 July 2026
Resolution: Received objective evidence matting put in front and rear of switchboard. Photos added to deficiency documents.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 March 2026 Resolved
Watertight integrity of vessel hull has been compromised. Vessel has active flooding in the bow thruster compartment coming from underneath an existing hole that was being contained by a temporary concrete patch. A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel shall proceed to drydock for permanent repairs. Owner shall provide transit plan for approval prior to departure. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2026
Resolution: Inspected repairs. Tested welds. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2025 Resolved
Starboard generator had coolant leak. All installations shall be of marine type engine suitable for the intended service. Make repairs to the satisfaction of the attending Coast Guard marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2025
Resolution: Gasket repaired. Received correction report from [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2025 Resolved
The reverse power relay failed during and test. Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2025
Resolved 18 May 2026
Resolution: 00 Def’s Issued, 00 Def’s Outstanding, 00 Def’s rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2025 Resolved
Port and starboard generators over speed failed during annual test. The control system shall be designed for automatic shutdown of the engine with the actuation of audible and visual alarms for over speed. Make reapirs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2025
Resolved 10 February 2026
Resolution: Observed overspeed on both generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 December 2025 Resolved
Port generator failed low lube oil pressure during annual test. The control system shall be designed for automatic shutdown of the engine with the actuation of audible and visual alarms for over speed. Make repairs to the satisfaction of the attending Coast Guard marine
Action required: 15 - Rectify deficiencies by next port
Due 31 December 2025
Resolved 10 February 2026
Resolution: Observed low lube oil pressure alarm.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 29 May 2025 Resolved
During SIP Audit/ Inspection - witnessed crewmember perform ICR inspection P 05 G. Noted control panel cover screws on top of panel. When panel was opened, found wires disconnected from one of the breakers. Crewmember was unaware of loose wires before preforming inspection. SIP rep stated the chief had Carrier working on system. System was not tagged out, required rep to have system tagged out.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 30 May 2025
Resolution: Received objective evidence the system was tagged out.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2025 Resolved
While witnessing crewmember perform ICR P-05 paragraph G. it was noted that wires were disconnected from one of the breakers inside the A/C control panel. Company is NOT following Safety Program procedures for log out tag out. Review procedure and provide training to ALL personnel.
Action required: 705 - Other - as specified
Due 29 August 2025
Resolved 28 July 2025
Resolution: Received objective evidence that training was conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 May 2025 Resolved
During SIP Audit/ Inspection - witnessed crewmember perform ICR inspection J-02 B. 1. Noted that the warmers on wheels and are unsecured and stationed near their deep fat fryers presenting a hazard. The electrical cables from the warmers are touching the handrails to the ladder coming into the space creating a potential electrical hazard if there were a short. Move warmers and plugs to a less hazardous location and properly secure warmers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 16 July 2025
Resolution: Verified warmers were moved into a safe location.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 March 2025 Resolved
Marine Inspector recognized the conditions of the concrete box patch in thruster tunnel to have changed. After further investigation, it was revealed that the temporary concrete patch was removed due to an ineffective installation and the vessel was intentionally beached on a sandy bottom and the crew installed a new box patch. The event was not logged, the repair was not indicated in the SIP correction report. SIP 2-99: Correction Reports become part of the company’s reporting mechanism and can be instrumental in identifying and correcting recurring problems with the vessel systems and subsystems. 46CFR71.55-1(a): No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery or equipment shall be made without the knowledge of the Officer in Charge, Marine Inspections. Multiple failures in the records keeping and deficiency reporting of structural watertight integrity company shall conduct training for the company SIP agent who is responsible for the implementation for the Vessel Action Plan. daily inspection records of the affected space shall be maintained that specifies water level and daily pump out. If any changes to the space occurs master shall contact the Officer in Charge Marine Inspections
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 19 May 2025
Resolution: BB Riverboats conducted training for the company SIP agent who is responsible for the implementation for the Vessel Action Plan. Daily inspection records of the affected space established 6March2025.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2024 Resolved
Vessel Rep could only provide three months of logbook entries. The master or person in charge of a vessel that is not required by 46 U.S.C. 11301 to have an official logbook, shall maintain, on board, an unofficial logbook or record in any form desired for the purposes of making entries therein as required by law or regulations in this subchapter. logs must be kept available for review by a marine inspector for a period of 1 year after the date to which the records refer. Maintain logbook records for a total of 1 year for inspection for review by a marine inspector to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 November 2023 Resolved
Vessel galley has a griddle and deep fryer fixed fire fire fighting system. Once the the fixed fire fighting system is activated the ventilation shall automatically stop the ventilation. During fire drill it was discovered that the ventilation shutdown was not working for all fans. Exhaust for galleys shall meet the applicable bulkhead requirements. In addition an automatic damper shall be installed in exhaust ducks over frying vats ect. Make repairs to the fixed fire fighting automatic ventilation shutdown in the galley. To the satisfaction of the attending Coast Guard Marine Inspector. Do not use deep fat fryer and griddle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 12 December 2023
Resolution: Comducted test of emergency ventilation shutdown with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 November 2023 Resolved
Galley ventilation above deep fat fryer and griddle had excessive grease buildup and lent that is at risk for fire. The general construction of the vessel shall be such as to minimize fire hazards. Clean ventilation above deep fat fryer and griddle to the satisfaction of the attending Coast Guard marine
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 12 December 2023
Resolution: Venilation was cleaned.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 November 2023 Resolved
Watertight door handle in the galley is coming into contact with an electrical panel cover which has partially broke free from bulkhead. If the electrical panel cover come completely out from bulkhead it will impede the WTD handle and prevent the door from closing in the event of a fire or flooding. The general construction of the vessel shall be such as to minimize fire hazards. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 12 December 2023
Resolution: Electrical panel secured to bulkhead.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 November 2023 Resolved
An extension cord supplying a freezer was handing over the top of the galley fryer vat creating a fire hazard. The general construction of the vessel shall be such as to minimize fire hazards. Remove extension cord over fryer vat to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 7 November 2023
Resolution: Extension cord was removed during inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 January 2023 Resolved
Vessel fixed fire fighting halon agent was accidentally discharged by Silco fire and security during test of the system leaving the engine room without a fixed fighting system. The company is waiting for a replacement bottle. An approved extinguishing system must be installed as required by table 76.05-1 on all self propelled vessels. Vessel shall not operate engine room machinery until fixed fire fighting system is repaired. Rectify deficiencies prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2023
Resolution: Conducted system test with satisfactory results. New bottle of Halon intsalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 August 2022 Resolved
Solenoid valve for generator failed.
Action required: 10 - Deficiency Rectified
Due 3 August 2022
Resolved 3 August 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 March 2022 Resolved
Vessel representative could not provide training form (B&B Riverboats Marine Employee Training System Employee Log) that is used to track employees training which is compulsory in the company action plan. The crew must be instructed in the use of the vessel's fire-extinguishing and lifesaving appliances and in survival at sea at the same interval as the drills. Individual units of instruction may cover different parts of the vessel's lifesaving and fire-extinguishing appliances, but all the vessel's lifesaving and fire-extinguishing appliances must be covered within any period of 2 months. n2-99 track and record training for individual employees, and the training required for the designated SIP support personnel to implement the CAP and the VAP. Provide marine employee training records in accordance with B&B Riverboats Company Action plan and vessel action plan to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 25 April 2022
Resolution: Received objective evidence crew training and audit
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2021 Resolved
Exit sign on first deck did not illuminate. Illumination exit signs are required and must be installed in accordance with Subchapter J. Repair exit sign to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 26 February 2021
Resolution: Exit sign repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2021 Resolved
Thirteen emergency light bulbs were extinguished or missing from the pilot house down to the first deck. Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide safe egress from the space. Repair/renew all extinguished or missing emergency lights to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 26 February 2021
Resolution: E light bulbs replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2021 Resolved
MI identified two wasted life jackets in rescue boat. Life jackets must meet approval requirements of 46 CFR1 199.70 Replace wasted life jackets to the satisfaction of the attending Coast Guard inspector.
Action required: 10 - Deficiency Rectified
Due 3 February 2021
Resolved 3 February 2021
Resolution: Two new PFDs replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 February 2021 Resolved
ICR A-02 of the companies SIP states that the notice to mariners are onboard for the intended operating area. The marine inspector noted no notice to mariner were onboard the vessel. Licensed deck officers are required to acquaint themselves with the latest information published by the Coast Guard and the National Geospatial-Intelligence Agency regarding aids to navigation. Neglect to do so is evidence of neglect of duty. It is desirable that all vessels have available in the pilothouse for convenient reference at all times a file of the applicable Notice to Mariners. Implement ICR A-02 of the companies SIP and provide notice to mariner for the intended operating area to the satisfaction of the Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 26 February 2021
Resolution: NTM were placed in the pilot house.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 August 2020 Resolved
Owner reported a failure of the battery charger for the ships service generator that subsequently reduced power for vessel and loss of steering pump. Operating generators must provide a continuous and uninterrupted source of power for this ships service under normal operational conditions. Conduct repairs to the battery charger for the ships service generator to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 5 August 2020
Resolved 5 August 2020
Resolution: Owner issued correction report verifying system was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2020 Resolved
During man overboard drill the Belle of Cincinnati's rescue boat engine stalled while underway and failed to start again. Each passenger vessel of less than 500gt must carry one rescue boat. Conduct repairs or replace rescue boat engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 19 February 2020
Resolution: Owner purchased and installed new small boat engine.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2020 Resolved
Rescue boat fire extinguisher was not in its bracket and had expired. Each passenger vessel of less than 500gt must carry at least one rescue boat that is equipped in table 199.175 of this part. Replace fire extinguisher and mount in fire extinguisher bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 19 February 2020
Resolution: MI observed new fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 February 2020 Resolved
During fire drill, two fire stations, one forward and second deck and the other located in the engine room, charged at the fire station while not in use. The outlet at each fire hydrant must be provided with a cock or valve fitted in such a position that the firehose may be removed while the fire main is under pressure. Conduct maintenance on the fire stations so that the fire station does not charge while not in use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 19 February 2020
Resolution: New gate valves were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 September 2019 Resolved
Affect repairs as necessary to ensure that oil is not discharged into the navigable waters of the U.S. via the vessel's port main diesel generator exhaust and/or effluent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 18 September 2020
Resolution: Owner satisfactory installed load bank.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 February 2019 Resolved
Hydrostatic release on Buoyant Appartus expired.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 March 2019
Resolved 6 March 2019
Resolution: Replaced hydrostatic release.
Electrical › Electric Generation Source (emergency) › Generator
Issued 5 February 2016 Resolved
Emergency generator low lub oil shut off not functioning.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2016
Communications › Audible Communications › Horn/Whistle
Issued 5 January 2016 Resolved
Horns removed for service. Temporarily being replaced by a supplemental air horn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 13 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 December 2015 Resolved
Determine the source(s) of diesel oil pollution and affect repairs as necessary to ensure that oil is not discharged into the navigable waters of the U.S. via the vessel's diesel engine(s) exhaust and/or effluent.
Due 15 February 2016
Resolved 8 February 2016
Resolution: Received letter from [name withheld] Systems CAT, attesting to proper overation of MDE.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 22 July 2012 Resolved
The exhaust in way of the port side generator has a 3" crack at the point where the exhaust penetrates the hull in the auxiliary machinery space. Three holes were drilled at the bottom of the pipe and fitted with drain plugs for the purpose of draining any excess water accumulated at the elbow. A temporary lap patch was welded over the crack. Permanent repairs will be completed during next DD.
Action required: 705 - Other - as specified
Due 14 November 2012
Resolved 4 December 2012
Resolution: Complete exhaust system for all five engines was replaced during the dry dock period in Paducah, KY.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 July 2009 Resolved
Prove proper operation of all waterlights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 5 August 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 July 2009 Resolved
Renew cracked waterlight second deck starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 5 August 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 July 2009 Resolved
Clear access to all stairwells where blocked by ships stores portside maindeck.
Condition: Improper/Lack of Maintenance
Due 28 July 2009
Resolved 5 August 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 5 February 2008 Resolved
Engine Room Halon tank is overdue for hydro testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 20 May 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 5 February 2008 Resolved
Heat Detector for emergency generator space not operating
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2008
Resolved 20 May 2008
Construction/Loadline › Hull › Hull Plating
Issued 9 November 2007 Resolved
Blast, guage, and provide repair proposal for the pitted area inside the bow thruster tube.
Due 16 November 2007
Resolved 14 November 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 November 2007 Resolved
Clean out the two sea valves clogged with debris located on the aft galley sea chest.
Due 16 November 2007
Resolved 14 November 2007
Documentation › Manuals/Policy Documentation › Vessel Action Plan (SIP)
Issued 1 February 2006 Resolved
Remove ICR-I-04, not applicable for vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 February 2006
Resolved 6 February 2006
Resolution: ICR removed.
Engineering › Pressure Vessel › Relief Valve
Issued 27 October 2004 Resolved
Prove proper operation of all four air receiver relief valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 February 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 January 2004 Resolved
Replace two burned out emergency lights in aft machinery room.
Action required: 705 - Other - as specified
Due 28 January 2004
Resolved 28 January 2004
Resolution: Bulbs replaced during course of inspection.
Engineering › Bilge Water Management System › Valve
Issued 24 October 2003 Resolved
Repair bilge suction valve reach rod in forward ballast tank.
Condition: Unknown
Due 28 November 2003
Resolved 31 October 2003
Resolution: Installed new reach rod.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 October 2003 Resolved
Free up/make repairs to forward fuel oil tank fuel cut off reach rods.
Condition: Unknown
Due 28 November 2003
Resolved 31 October 2003
Resolution: Installed new reach rods.
Engineering
Issued 24 October 2003 Resolved
Open, clean and inspect heating furnace prior to placing unit into operation. Clean aft machinery space of soot from heating furnace.
Action required: 705 - Other - as specified
Due 26 December 2003
Resolved 28 January 2004
Resolution: Boiler was seviced and running, all areas of the aft machinery room were as cleaned.
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2003 Resolved
Vessel must have a corrosion survey completed to determine the cause and corrective actions needed to stop/arrest corrosive action to hull of vessel in way of hull plating behind port and stbd keel coolers. Survey report to be submitted to [name withheld] DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 3 March 2004
Resolution: A corrosion survey was conducted on the RIVER QUEEN and the examiner gave a cursory examination to the BELLE OF CINCINNATI, the problem was a poor ground between the vessel and the shore tie connection, a new transformer and cable were installed.
Lifesaving
Issued 5 December 2001 Resolved
REPAIR AUX MACHINERY ROOM EMERGENCY ESCAPE HATCH STARBOARD SIDE.
Condition: Unknown
Due 5 January 2002
Resolved 7 January 2002
Electrical
Issued 5 December 2001 Resolved
MAKE REPAIRS TO ELECTRICAL PANEL NUMBER 4C. LATCH FOR DOOR BROKEN/MISSING.
Condition: Unknown
Due 5 January 2002
Resolved 7 January 2002
Fire Fighting
Issued 23 May 2001 Resolved
MOUNT FIRE EXTINGUISHER BRACKET FOR PORTABLE EXTINGUISHER INSIDE AUX MACHINERY SPACE WTD.
Condition: Unknown
Due 15 June 2001
Resolved 15 August 2001
Construction/Loadline
Issued 23 May 2001 Resolved
REPAIR LEAKING SLOP OIL DISCHARGE LINE IN STEERING COMPARTMENT, CLEAN OIL AND WATER FROM BILGE.
Condition: Unknown
Due 15 June 2001
Resolved 15 August 2001
Accommodation/Occupational Safety
Issued 23 May 2001 Resolved
CLEAN OR APPLY NON-SKID ON LADDER INTO GALLEY.
Condition: Unknown
Due 15 June 2001
Resolved 15 August 2001
Engineering
Issued 27 February 2001 Resolved
REPLACE AND SHOW PROPER OPERATION OF ENGINE ALARM SENSORS #1, #4, AND #11.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Lifesaving
Issued 27 February 2001 Resolved
CONDUCT FIRE NAD MAN OVERBOARD DRILLS.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Lifesaving
Issued 5 September 2000 Resolved
WHEN ONLY 2 IBA ARE ONBOARD, MAX TOTAL PERSONS ALLOWED IS 1000, MAXIMUM PASSENGERS ALLOWED IS 868. FOR EACH PERSON IN ADDITION TO CREW THAT MAY BEREDUCED, THE NUMBER OF PAX ALLOWED MAY BE INCREASED BY LIKE NUMBER. TOTAL NUMBER OF PASSENGERS AND PERSONS IN ADDITION TO CREW IS NOT TO EXCEED 990.
Condition: Unknown
Due 5 September 2000
Resolved 5 September 2000
Deck/Cargo
Issued 22 August 2000 Resolved
LOCATE AND REPAIR OIL LEAK, SUSPECTED FROM STACK RAISE/LOWER HYDRAULIC SYSTEM, IN THE COMPARTMENT LOCATED UNDER THE PILOT HOUSE.
Condition: Unknown
Due 22 September 2000
Resolved 6 October 2000
Electrical
Issued 22 August 2000 Resolved
REPAIR/REPLACE AS NECESSARY AND PROVE SATISFACTORY OPERATION OF THE EMERGENCY LIGHT OVER THE AFT DANCE FLOOR, 3RD DECK.
Condition: Unknown
Due 22 September 2000
Resolved 6 October 2000
Engineering
Issued 22 August 2000 Resolved
LOCATE THE SOURCE OF ALL ENGINE(S) EXHAUST LEAKS INTO THE AFT AUX SPACE, REPAIR, AND PROPERLY COMPLETE LAGGING OF THE EXHAUST SYSTEM(S).
Condition: Unknown
Due 22 September 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 22 August 2000 Resolved
GENERAL CLEANING OF GALLEY INCLUDING OVERHEAD, BULKHEADS, DECKS, AND FOOD PREP AREAS/SURFACES.
Condition: Unknown
Due 22 September 2000
Resolved 6 October 2000
Accommodation/Occupational Safety
Issued 22 August 2000 Resolved
REPLACED FRACTURED WINDOW GLASS IN THE DOOR, STBD SIDE MAINDECK "CREW ONLY"DOOR TO GALLEY.
Condition: Unknown
Due 22 September 2000
Resolved 6 October 2000
Navigation
Issued 22 February 2000 Resolved
PROVE STAISFACTORY OPERATION OF THE RUDDER ANGLE INDICATOR LOCATED IN THE ENGINEERS OPERATING STATION
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Navigation
Issued 22 February 2000 Resolved
PROVE SATISFACTORY OPERATION OF ALL STEERING SYSTEM ALARMS
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Electrical
Issued 22 February 2000 Resolved
PROVE SATISFACTORY OPERATION OF ALL EMERGENCY GENERATOR ALARMS AND SAFETIES
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Engineering
Issued 22 February 2000 Resolved
PROVE SATISFACTORY OPERATION OF ALL ALARMS AND SAFETIES ON ALL 3 PROPULSIONENGINES
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Lifesaving
Issued 22 February 2000 Resolved
CONDUCT MAN OVERBOARD, FIRE, AND ABANDON SHIP DRILLS WITH THE REQUIRED CREWON BOARD.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Fire Fighting
Issued 22 February 2000 Resolved
INSTALL HALON ACTIVATION WARNING PLACARD IN AFT AUX MACHINERY SPACE AT A LOCATION NEAR THE ALARM SIREN.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Fire Fighting
Issued 22 February 2000 Resolved
RELOCATE ENGINE ROOM HALON SYSTEM ACTIVATION WARNING PLACARD TO A LOCATION NEAR THE ALARM SIREN.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Electrical
Issued 22 February 2000 Resolved
PROVE SATISFACTORY OPERATION OF ALL ALARMS AND SAFETIES ON #1 AND #2 SHIP SERVICE GENERATOR DRIVE ENGINES
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Electrical
Issued 22 February 2000 Resolved
PROPERLY INSTALL JUNCTION BOX COVER LOCATED ABOVE THE RUDDER ANGLE INDICATOR SENDING UNIT IN THE LAZARETTE
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Electrical
Issued 22 February 2000 Resolved
PROPERLY INSTALL LIGHT FIXTURE IN TANK ROOM AT FORWARD BULKHEAD
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Lifesaving
Issued 22 February 2000 Resolved
RESTOCK REQUIRED FIRST AID KIT, LOCATED IN PILOT HOUSE
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Fire Fighting
Issued 20 October 1999 Resolved
SUBMIT SPRINKLER SYSTEM ELECTRICAL PLANS FOR APPROVAL.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Lifesaving
Issued 28 July 1999 Resolved
PRIOR TO COMMENCING NORMAL UNDERWAY OPERATIONS WITH PASSENGERS ABOARD, CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Accommodation/Occupational Safety
Issued 28 July 1999 Resolved
PROVIDE "EMERGENCY EXIT - KEEP CLEAR" WARNINGS VICINITY OF LADDER EGRESS_x001C_ FROM THE AUX MACHINERY SPACE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Fire Fighting
Issued 28 July 1999 Resolved
SEAL HOLES VIA THE USE OF FIRE CAULKING OR OTHER APPROVED METHOD IN FIRE DOORS/DOOR FRAMES WHICH RESULTED FROM THE REMOVAL OF OLD DOOR HARDWARE. TO BE DONE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Lifesaving
Issued 28 July 1999 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS INCLUDING OPERATIONS VIA EXCURSION PERMITS, REMOVE ALL PAINTS, THINNERS AND SIMILAR FLAMMABLES FROM VESSEL.
Condition: Unknown
Due 31 July 1999
Resolved 6 August 1999
Lifesaving
Issued 2 July 1999 Resolved
Ensure all ladders in and out of hold deck have adequate emergency lighting. No passengers will be below main deck until completed.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Submit final load calculations for main bus and emergency bus to MSC for approval.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Lifesaving
Issued 2 July 1999 Resolved
Provide new/clean exit globes on all exits throughout vessel.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Lifesaving
Issued 2 July 1999 Resolved
Make vessel available for CG Marine Inspector to inspect general housekeeping and electrical safety throughout vessel.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 2 July 1999 Resolved
Remove all oily water from engine room and prove bilge suction in engine room.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 2 July 1999 Resolved
Obtain approval for sprinkler system and install system as approved.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Lifesaving
Issued 2 July 1999 Resolved
Submit final EEP to MSO Louisville for approval.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Unknown
Issued 2 July 1999 Resolved
PROVE EMERGENCY GENERATOR LOSS OF LUBE OIL SHUT-DOWN, OVERSPEED PROTECTION AND ASSOCIATED ALARMS; PROVE JACKET WATER HIGH TEMP ALARM
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Accommodation/Occupational Safety
Issued 2 July 1999 Resolved
Remove all temporary appliances in galley and install permanent equipment in galley.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Documentation
Issued 2 July 1999 Resolved
Submit new deadweight survey to MSC for approval, receive stability letter from MSC prior to getting underway with passengers.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 2 July 1999 Resolved
Submit final fire/safety plan for approval. Post approved plan throughout vessel.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Engineering
Issued 2 July 1999 Resolved
Repair or replace bowthruster control on port bridge wing._x001C_
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Cleanup and secure all wiring in electrical spaces on main deck aft. Only authorized members of the crew are allowed in these spaces.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Documentation
Issued 2 July 1999 Resolved
Provide original copies of USCG COFR and vessel's COD onboard.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Provide and prove emergency lighting in eng room and aux mach space; and galley and crew accomodation spaces.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Repair exhaust ventilation blower in aux mach space to provide adequate space ventilation.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Unknown
Issued 2 July 1999 Resolved
Provide and prove low start air pressure alarm.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Label emergency stop controllers for engine room ventilation on main deck.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Unknown
Issued 2 July 1999 Resolved
Repair exhaust leaks in piping in aux mach space.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Provide warning placard for main switchboard and emergency switchboard.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Provide and prove service lighting in forward hold and in steering room.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Prove loudspeaker in engine room control booth.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Engineering
Issued 2 July 1999 Resolved
Prove operation of low pressure heating boiler to include safety and automation and associated pressure vessel.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 2 July 1999 Resolved
Prove proper operation of WTD #2 to aux machinery room.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Unknown
Issued 2 July 1999 Resolved
Provide heat shield lagging over turbo on emerg generator.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Secure all battery boxes in engine room.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 2 July 1999 Resolved
Provided auto-closing devices for engine room doors on main deck
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Remove all dead-end cables from elec. panel boards and throughout ship.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Secure all panel boards, label and provide circuit directories for same in accordance with 46CFR sub J.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Properly connect wires in cable to bilge high level sending unit in forwardhold space.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Provide indicator light for main switchboard ground fault detector, center position.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Electrical
Issued 2 July 1999 Resolved
Provide electrical safety matting for main and emergency switchboards.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 25 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS COMPLETE REQUIRED DRILLS WITH THE FULL CREW ONBOARD. THIS TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATER THAN 25MAY95.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 6 January 1994 Resolved
Prior to carrying passengers, new stability calculations must be submitted and the vessel must have a current stability letter on board.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Construction/Loadline
Issued 28 July 1993 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 28 July 1993
Resolved 28 July 1993
Electrical
Issued 28 July 1993 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 28 July 1993
Resolved 28 July 1993
Engineering
Issued 12 April 1993 Resolved
PROVIDE FUEL OIL DISCHARGE CONTAINMENT FOR THE EMERGENCY GENERATOR DAY TANKVENT PIPE IN ACCORDANCE WITH 33 CFR 155.320 (A)(1).
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Engineering
Issued 12 April 1993 Resolved
PROVIDE FUEL OIL TRANSFER PUMP WITH 46 CFR 58.01-25 AND 46 CFR 111.103-9
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Fire Fighting
Issued 2 February 1993 Resolved
WALL MOUNTED AND FREE STANDING "PLASTIC" FACED NEON LIGHTING THROUGHOUT THEVESSEL DOES NOT EXCEED THE APPROVED FIRE LOAD RATING.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Accommodation/Occupational Safety
Issued 11 January 1993 Resolved
REPLACE PLEXIGLAS WINDOW, PORT SIDE AFT, ON BOILER DECK WITH PROPER GLASS.
Condition: Unknown
Due 11 January 1993
Resolved 11 January 1993
Accommodation/Occupational Safety
Issued 11 January 1993 Resolved
PROVIDE COAST GUARD APPROVED DOCUMENTATION FOR MIRRORED CEILING TILES OR REPLACE THEM WITH APPROVED MATERIAL.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Lifesaving
Issued 29 July 1992 Resolved
PROVIDE UNDERWAY EEP APPROVED BY CG HEADQUARTERS G-MSC.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Engineering
Issued 7 May 1992 Resolved
REPAIR ALARM PANEL TO THE PORT MAIN PROPULSION ENGINE.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Accommodation/Occupational Safety
Issued 7 May 1992 Resolved
PROVIDE APPROVED PLANS FOR THE CONVERSION OF THE LOCKER ROOM'S MEN'S ROOM INTO A STORE ROOM OR RESTORE IT BACK INTO A MEN'S ROOM.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Navigation
Issued 7 May 1992 Resolved
REPAIR SWITCH TO STEERING SYSTEM AND DEMONSTRATE PROPER OPERATION WHEN IN THE FOLLOW-UP MODE USING NO#1 PUMP.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Documentation
Issued 7 May 1992 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Accommodation/Occupational Safety
Issued 21 February 1992 Resolved
PERMANENTLY INSTALL GALLEY INTAKE AIR DUCT.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Electrical
Issued 21 February 1992 Resolved
PROVIDE SUITABLE JUNCTION BOX FOR SEWAGE COMPARTMENT HEATER FAN.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Fire Fighting
Issued 21 February 1992 Resolved
INSTALL FIRE DOORS AS PER APPROVED PLANS.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Electrical
Issued 21 February 1992 Resolved
PROVIDE PERMANENT ELECTRICAL PLUGS FOR HEAT TAPE. (SEWAGE COMPARTMENT)
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Accommodation/Occupational Safety
Issued 11 December 1991 Resolved
Provide suitable ventilation to aft engineering compartment.
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Accommodation/Occupational Safety
Issued 5 December 1991 Resolved
Remove all trash cans made of plastic. Trash cans shall be made of approved non-combustible materials. (metal)
Condition: Unknown
Due 5 January 1992
Resolved 7 February 1992
Accommodation/Occupational Safety
Issued 9 September 1991 Resolved
PROVIDE SUITABLE VENTILATION TO AFT ENGINEERING COMPARTMENT.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Engineering
Issued 9 September 1991 Resolved
NOTED EXCESSIVE VIBRATION TO THE PORT MAIN ENGINE WET EXHAUST._x001C_ PROVIDE PROPOSAL TO CORRECT PRESENT SITUATION.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Electrical
Issued 9 September 1991 Resolved
RENEW PORT GENERATOR VOLTAGE REGULATOR.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Engineering
Issued 9 September 1991 Resolved
PROVIDE AN ALARM TESTING PROCEDURE FOR THE PRIME MOVERS' ALARM SYSTEM.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Lifesaving
Issued 9 September 1991 Resolved
INSTALL A CLEAT FOR SEAPAINTER TO BOTH (P/S) RESCUE BOATS.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Accommodation/Occupational Safety
Issued 9 September 1991 Resolved
GALLEY NEEDS COMPLETE CLEANING.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Unknown
Issued 9 May 1991 Resolved
COMPLETE 7 ITEM WORK LIST.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991

Casualty record · 11

7 July 2004Routine · role: Involved in a Marine Casualty · at B & O RR BRIDGE · activity 2138135
29 September 2006Routine · role: Involved in a Marine Casualty · at U.S. 25 BRIDGE · activity 2795555
29 October 2010Routine · role: Involved in a Marine Casualty · activity 3881128
23 March 2012Routine · role: Involved in a Marine Casualty · activity 4283600
25 October 2012Routine · role: Involved in a Marine Casualty · at SMITHLAND LOCK & DAM · activity 4548857
16 November 2012Routine · role: Involved in a Marine Casualty · activity 4549524
11 December 2014Routine · role: Involved in a Marine Casualty · at SOUTHERN RAILROAD BRIDGE · activity 5038295
13 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6794901
1 August 2020Routine · role: Involved in a Marine Casualty · activity 7043895
8 May 2022Routine · role: Involved in a Marine Casualty · at TAYLOR-SOUTHGATE BRIDGE · activity 7446795
26 March 2026Routine · role: Involved in a Marine Casualty · activity 8338620
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.