MACKINAC EXPRESS

Built
1987
Last inspected
29 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 October 2025
…with no type recorded10
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI9130
281582
Flag
UNITED STATES
Maury page id
psix-281582

Documentation record

Registered dimensions (L × B × D)80.7 ft × 28.2 ft × 8.3 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)80.7 ft × 28.2 ft × 8.3 ft
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 1987
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMACKINAC ISLAND, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
84 - Displacement, Ton
92 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 62 inspections, each with its date, unit and type; 70 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 62

29 October 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8260330
13 January 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062796
9 September 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999112
26 June 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7943383
26 June 2024 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7949800
28 May 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7921355
28 May 2024 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7924055
27 March 2024 Annual Inspection · Examination of Repairs · Damage Survey · MTSA Verification · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7898203
18 August 2023 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7771573
18 August 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7780250
27 July 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814606
19 June 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7718357
18 June 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7719795
7 May 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7683115
7 May 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7685840
17 April 2023 Annual Inspection · MTSA Verification · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7671462
31 October 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7586685
16 October 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7578357
16 October 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7580468
11 August 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7534379
9 May 2022 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7476256
22 October 2021 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7340533
10 September 2021 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7309439
8 September 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7313414
23 August 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7296111
5 August 2021 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341809
23 July 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7268120
1 June 2021 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7211498
17 May 2021 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7193712
13 April 2021 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7174568
4 November 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7130740
3 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7049361
5 August 2020 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7026315
1 July 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6992993
12 November 2019 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6856528
9 October 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6831601
16 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6752122
7 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6740477
7 July 2019 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6785346
20 June 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6736926
30 April 2019 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6703248
22 April 2019 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6668504
18 October 2018 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6563894
18 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6543358
26 July 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6506857
25 July 2018 Administrative Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6490394
27 June 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6458142
4 June 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6434627
3 June 2018 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6433671
9 May 2018 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6422115
14 March 2018 Damage Survey · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6402477
27 December 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6334844
29 November 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6327661
19 October 2017 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6293450
10 October 2017 Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6288661
28 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277315
22 August 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6276862
3 July 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6198825
11 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6173860
4 May 2017 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6149284
29 August 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6009953
31 March 2016 Plan Review (Other than "T") · Drydock Exam · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5848638

Deficiency record · 70

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 April 2024 Resolved
Pilothouse fire detection & alarm panel display showing nothing, not powered or functioning. Servicing company found main circuit board to be faulty. New board ordered. Provide technician report attesting to repair and proper operation of fire detection and alarm system and all related components, i.e. sensors, pull stations, strobes and alarms.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 April 2024
Resolved 23 April 2024
Resolution: Received technician report following fire alarm system panel install and system testing. Tests were satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 April 2024 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 30 June 2024 — due date passed with no resolution recorded
Resolution: Temporary repairs are regularly checked and show no signs of failing. Def extended until end of season.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precautions against hazards that might endanger the vessel and the person being transported. Vessel is authorized to proceed to St. Ignace, MI under reduced propulsion utilizing the port engine without any passengers on board. Vessel shall have a second company vessel along side available and equipped to assist in towing evolution if required. Vessel shall conduct repairs and provide inspection/testing to the satisfaction of the local OCMI prior to departure from St. Ignace, MI. Vessel shall keep local OCMI informed of any changes in propulsion capabilities during transit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2023
Resolved 1 September 2023
Resolution: MDE repaired & operationally tested. CID cleared vessel to oeprate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Starboard MDE experienced inconsistent RPMs, rendering it inoperable. Conduct causal analysis and complete permanent repairs to the satisfaction of attending CG marine inspectors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2023
Resolved 26 June 2023
Resolution: Michigan Cat Technicians completed causal analysis and permanent repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2023 Resolved
Install protective covers to electrical terminals in battery storage closet and cleaning closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 April 2023
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2023 Resolved
Vessel material condition found to unsatisfactory for the safe carriage of passengers. No carriage of passengers is allowed until CG MI returns to complete inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2023
Resolved 19 April 2023
Resolution: Vessel condition corrected, def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2023 Resolved
All MDE turbo exhaust lagging is required to be properly tightened and have retaining wire/springs installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2023
Resolved 19 April 2023
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 April 2023 Resolved
Repair cracked welds in port void #1,2,3 & stbd void #1. Submit plans for stbd bow damage, repair accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 31 August 2023
Resolution: permanent repairs completed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 April 2023 Resolved
Both enginerooms overhead insulation must be cleaned and properly installed, all seams must be sealed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2023
Resolved 19 April 2023
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2023 Resolved
Engineroom FFE systems have been serviced however tech report shows time delays released under allowable limits. Re-test with CG MI witness or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2023
Resolved 24 April 2023
Resolution: Port time delay tested sat; stbd time delay replaced & properly tested in my presence.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 August 2022 Resolved
Found guard for the alternator broken in place and resting on the spinning belt. Captain shut down the affected engine and mechanics removed the broken guard. Replace broken guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 31 August 2022
Resolution: replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2022 Resolved
Multiple cracked welds sighted, require repair. Stbd forepeak, port #2 void at chine, stbd qtr ramp & bulwarks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 18 May 2022
Resolution: repaired
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 9 May 2022 Resolved
Uppermost deck seating not safe for passengers, uppermost deck is made inaccessible to passengers. Limited passenger count appropriately.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 18 May 2022
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 May 2022 Resolved
1 IBA found installed incorrectly.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2022
Resolved 9 May 2022
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2022 Resolved
Stbd engineroom aft fire/smoke detector melted, requires replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 1 June 2022
Resolution: replaced, ops tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2022 Resolved
Port engineroom alternator cover missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 9 May 2022
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 May 2022 Resolved
Port engineroom MDE & genset emergency fuel shutoffs inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2022
Resolved 10 May 2022
Resolution: repaired, witnessed operational test, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2021 Resolved
Determine cause and effect permanent repairs to stbd MDE. Demonstrate proepr operatin to attending MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2021
Resolved 16 September 2021
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 July 2021 Resolved
Port steering bucket hydraulic actuator anodes were discovered to be loose and a hazard to possible steering jam/failure.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2021
Resolved 14 July 2021
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 July 2021 Resolved
Repair cracked welds in both port & stbd forepeaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 July 2021
Resolution: corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2021 Resolved
4 fiberglass seats on top deck are cracked & pose a hazard to passengers. Replace or make inaccessible to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 July 2021
Resolution: replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 June 2021 Resolved
The port main has a coolant leak that caused the engine to overheat.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2021
Resolved 2 June 2021
Resolution: Operator sent pictures of permanent repairs
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 May 2021 Resolved
Port forepeak gusset repaired temporarily, permanent repairs required after 2021 operating season.
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 2 May 2022
Resolution: repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020 Resolved
Stbd engineroom bilge alarm wiring must be correctly routed through electrical junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 4 November 2020
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 September 2020 Resolved
Install protective device to minimize accidental contact with forwardmost inboard 12 volt light socket in stbd engineroom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 4 November 2020
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2020 Resolved
Repair port MDE oil drain line fitting oil leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 4 November 2020
Resolution: repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2020 Resolved
Repair cracked weld in #2 port side void and 2 cracks in forepeak inboard sponson frame structures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 21 May 2021
Resolution: repaired.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 12 November 2019 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow of the vessel. The vessel name on the stbd bow is illegible. Meet requirements of vessel name markings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 November 2019 Resolved
Master did not have medical card to prove medical qualification. Provide record of medical certificate issued by National Maritime Center.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 November 2019 Resolved
Each vessel must be equipped with at least two operable portable battery lights. The portable light at the operating station is inoperable. Provide operable portable light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 November 2019 Resolved
Vessel must be equipped with public address system. Public address system is inoperable. Comply with requirements for public address system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 November 2019 Resolved
Bilge hand pump is required for spaces forward of collision bulkhead. Hand pump is inoperable. Make hand bilge pump operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 November 2019 Resolved
Most forward port bilge alarm is inoperable. Make this bilge alarm operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 November 2019 Resolved
Each lighting fixture must have a guard or be made of high strength material. Stbd jetroom light does not have a guard. Properly guard this light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 November 2019 Resolved
The installation of portable fire extinguishers must be to the satisfaction of the cognizant OCMI. The stbd forward fire extinguisher on the main deck is not properly secured to the deck or bulkhead. Properly secure this fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 November 2019 Resolved
Compass must be illuminated. Make compass illuminated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 12 November 2019 Resolved
A seat must be constructed to minimize possibility of injury. 30 seats on the most upper deck are broken. Replace these broken seats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 November 2019 Resolved
All observed unsafe practices and hazardous situations must be corrected. The base of the hand rails on the ladderwells to both the 2nd and 3rd decks are cracked. Make these hand rails structurally sound to prevent injury of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 November 2019 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of 2 years after the date on which the unit is installed. 3/4 hydrostatic releases are expired. 1/4 hydrostatic release is not marked with expiration date. Replace the 3 expired hydrostatic releases and properly mark the unmarked hydrostatic release with the correct installation date.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 November 2019 Resolved
In the port forepeak, the weld between the 5th stiffener from the port side and deck is cracked. On the stbd side of the port forepeak, where multiple structures meet, a weld is cracked. Furthermore in the port forepeak, the welds on the stbd side #5,6,7 longitudinal stiffeners are cracked. In the 2nd void aft of the bow on the port side, the weld between the 2nd transverse frame and the port side chine is cracked. 1 crack was found in the stbd fore peak. Repair all cracked welds to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 July 2019 Resolved
unauthorized wire nuts under the helm station and dead-end control wires in several junction boxes, properly dead-end all wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2019
Resolved 1 August 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2019 Resolved
clean and pump port sponson engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2019
Resolved 1 August 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 July 2019 Resolved
Determine cause of loss of propulsion control from stbd bridge "wing" operating station. Effect permanent repairs to the same and provide report to [name withheld]. Repairs shall be made to the satisfaction of the attending Coast Guard Marine Inspector, subject to the following additional provisions: (a) Vessel is authorized a one-time transit from Mackinac Island to Mackinaw City to facilitate further troubleshooting and repairs. (b) Complete permanent repairs prior to departure from Mackinaw City. (c) Demonstrate proper operation of each operating stations main propulsion controls prior to the carriage of passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2019
Resolved 10 July 2019
Resolution: Cleared, see activity narrative.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 October 2018 Resolved
Replace structural fire protection on bulkhead of engine room prior to next operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 20 June 2019
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2018 Resolved
Clean port and starboard engine rooms of exhaust leak soot prior to next operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 20 June 2019
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018 Resolved
The vessel is currently broadcasting (1) Zero Length and Beam, (2) Zero Draft, (2) No Ship type. The Ship should be 60 per the US official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 14 July 2021
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 July 2018 Resolved
Labeling illegible on bilge manifold valves in both enginerooms, to be corrected as per good marine practice.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 August 2018
Resolved 2 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2018 Resolved
Repair exhaust insulation lagging for both main engine to prevent ignition of combustible materials.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2018
Resolved 2 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2018 Resolved
Repairs to the machinery that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] permanent repairs to port engine. Make available for functional testing both engines within one (01) week.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2018
Resolved 26 July 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2018 Resolved
It was noted that the vessel only had an expired Certificate of Documentation (COD) on board. Prior a valid COD w/in 30 days to the satisfaction of the OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 26 July 2018
Resolution: this had been verified earlier but not cleared in MISLE.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 June 2018 Resolved
The bridge deck, forward, stbd childsize life jacket storage was labelled twice, once above and below the life jacket storage, however one indicated 15 life jackets, the other 16 life jacket. Properly mark life jacket storage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 8 June 2018
Resolution: Took down incorrect placard.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 4 June 2018 Resolved
Main deck, stbd, forward portable fire extinguisher sign was found falling off the bulkhead due to failing duct tape. Properly mount the fire extinguisher sign on the bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Resolution: Sign was screwed to the bulkhead.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2018 Resolved
The stern navigation light's lens was found to have over sprayed paint on it, which distorts the proper display of the light to other vessels. Make proper repairs to the navigational light prior to operating from dusk to sun rise or during periods of limited visibility.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 4 June 2018
Resolved 5 June 2018
Resolution: Navigation light lens was properly cleaned.
Engineering › Thrusters › Pump
Issued 3 June 2018 Resolved
Vsl sucked bird into jet drive causing loss of propulsion. Make operable propulsion system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2018
Resolution: Jet drive was found fully operational.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 October 2017 Resolved
jet propulsion hydraulic hoses chafed. replace and provide anti-chafe material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 26 July 2018
Resolution: this had been verified earlier but not cleared in MISLE.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 October 2017 Resolved
Engineroomaccess doors must close tightly and be fitted with positive latches. they must be marked with "fire boundary - keep closed"
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 27 December 2017
Resolution: Extended additional 2 weeks on 29NOV per owner request. See email "Documents"
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 October 2017 Resolved
Provide properly serviced PFEs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2017
Resolved 19 October 2017
Resolution: PFEs replaced with properly serviced extinguishers.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 10 October 2017 Resolved
Make repairs to overheating port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2017
Resolved 13 October 2017
Resolution: Unclogged coolant line and replaced inop thermostat.
Communications › Alarms/Indicators › Fire Alarm
Issued 22 August 2017 Resolved
Repair and demonstrate operation of fire alarm strobe light in starboard engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: demonstrated full functionality in my presence
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 August 2017 Resolved
Repair worn/damaged structural fire protection insulation in both engineroom entrances.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: repaired with Promat glue
Documentation › Markings/Placards › Warning Signs
Issued 22 August 2017 Resolved
Provide effective signs or markings in port and starboard engineroom entrances for fire pump control switch, fire damper controls, CO2 pull stations and fire alarm pull stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: all signage appropriately posted in both engineroom accesses.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 22 August 2017 Resolved
Make proper and permanent repairs to main engine cooling system piping, leaks and supports.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2017
Resolved 24 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 22 August 2017 Resolved
Make proper repairs to both main engine exhaust systems to eliminate excessive exhaust leaks and protective insulation to prevent contact with combustible materials.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2017
Resolved 24 August 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 August 2017 Resolved
Remove excessive oily mixtures from bilges in both enginerooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 29 August 2017
Resolution: removed
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 July 2017 Resolved
Due to passenger vessel seating being broken and removed from service, reduce passenger count by 6 persons to 339 total passengers. Make proper repairs to seats to the satisfaction of the attending marine inspector, per 46 CFR 115.112.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 5 July 2017
Resolution: Made proper repairs to the seating.
Electrical › Electric Generation Source (service) › Generator
Issued 3 July 2017 Resolved
Main engine alternators require general maintenance, loose guards and disconnected wiring found during in service inspection. Verified corrected. Owner counselled regarding maintenance shortcomings.
Condition: Improper/Lack of Maintenance
Due 3 July 2017
Resolved 5 July 2017
Resolution: Corrected, per followup visit
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 11 June 2017 Resolved
Prior to operation make permanent repairs to propulsion machinery and demonstrate proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2017
Resolved 15 June 2017
Resolution: Replaced sensor
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 August 2016 Resolved
Provide a Certificate of Documentation that reflects the vesse's current dimensions and tonnage, prior to operating in commercial service in 2017.
Condition: Invalid
Due 15 May 2017
Resolved 7 May 2017
Fire Fighting › Fixed Fire Detection System › Approval
Issued 31 March 2016 Resolved
Existing fire detection system operates satisfactory but is not approved. Submit to the MSC a proposal for approval to install an approved fire detetion and alarm system.
Condition: Improper Installation
Due 27 August 2016
Resolved 26 September 2016
Fire Fighting › Fixed Fire Detection System › Approval
Issued 31 March 2016 Resolved
Complete installation of an approved fire detection and alarm system, meanwhile keep existing unapproved system in operational condition.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 22 August 2017
Resolution: installed & tested in CG presence

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.