Records from 1987 to 2025. Most recent: inspection, 29 October 2025.
Inspection history · 117
29 October 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8260330
13 January 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062796
9 September 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999112
26 June 2024
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7943383
26 June 2024
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7949800
28 May 2024
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7921355
28 May 2024
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7924055
27 March 2024
Annual Inspection · Examination of Repairs · Damage Survey · MTSA Verification · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7898203
18 August 2023
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7771573
18 August 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7780250
27 July 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814606
19 June 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7718357
18 June 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7719795
7 May 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7683115
7 May 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7685840
17 April 2023
Annual Inspection · MTSA Verification · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7671462
31 October 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7586685
16 October 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7578357
16 October 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7580468
11 August 2022
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7534379
9 May 2022
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7476256
22 October 2021
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7340533
10 September 2021
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7309439
8 September 2021
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7313414
23 August 2021
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7296111
5 August 2021
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341809
23 July 2021
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7268120
1 June 2021
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7211498
17 May 2021
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7193712
13 April 2021
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7174568
4 November 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7130740
3 September 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7049361
5 August 2020
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7026315
1 July 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6992993
12 November 2019
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6856528
9 October 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6831601
16 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6752122
7 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6740477
7 July 2019
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6785346
20 June 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6736926
30 April 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6703248
22 April 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6668504
18 October 2018
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6563894
18 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6543358
26 July 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6506857
25 July 2018
Administrative Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6490394
27 June 2018
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6458142
4 June 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6434627
3 June 2018
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6433671
9 May 2018
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6422115
14 March 2018
Damage Survey · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6402477
27 December 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6334844
29 November 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6327661
19 October 2017
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6293450
10 October 2017
Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6288661
28 September 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277315
22 August 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6276862
3 July 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6198825
11 June 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6173860
4 May 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6149284
29 August 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6009953
31 March 2016
Plan Review (Other than "T") · Drydock Exam · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5848638
30 June 2012
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4361712
26 June 2012
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4359560
21 June 2012
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4350999
21 June 2012
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4357042
8 May 2012
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4305933
15 December 2011
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4208997
1 May 2009
Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3700564
29 April 2009
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3464622
17 June 2008
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3239932
16 June 2008
Damage Survey · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3245366
29 May 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3222016
5 July 2007
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2985968
31 May 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2948844
19 April 2007
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2911634
2 April 2007
Plan Review (Other than "T")
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2910480
24 May 2006
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2658267
14 June 2005
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2390129
2 June 2005
MTSA Verification
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2376742
28 May 2004
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2087213
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978134
29 May 2003
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1808604
29 August 2002
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1668419
21 August 2002
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1665091
23 June 2002
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1635118
4 September 2001
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 143775
24 August 2001
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 165067
25 May 2001
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1451727
20 February 2001
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1058496
19 September 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 142877
21 July 1999
Examination of Repairs
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1462004
16 July 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 151618
21 May 1999
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1384159
23 April 1998
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1406309
6 October 1997
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1339170
22 July 1997
Plan Review "T" Boat
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 780129
16 July 1997
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 781235
1 May 1997
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1105256
31 May 1996
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1188923
6 May 1996
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1084020
9 May 1995
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1347377
23 September 1994
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 169150
5 May 1994
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1167440
11 April 1994
Damage Survey · Examination of Repairs
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1165941
28 April 1993
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1145825
9 August 1992
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 99181
28 April 1992
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1134157
6 March 1992
Administrative
Administrative · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1317961
12 February 1992
Hull Examination
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1314990
1 May 1991
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 998513
1 May 1990
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1235897
2 May 1989
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 895365
16 May 1988
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1041186
28 April 1988
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1345695
21 October 1987
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1020026
19 June 1987
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1339201
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 April 2024
Resolved
Pilothouse fire detection & alarm panel display showing nothing, not powered or functioning. Servicing company found main circuit board to be faulty. New board ordered. Provide technician report attesting to repair and proper operation of fire detection and alarm system and all related components, i.e. sensors, pull stations, strobes and alarms.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 April 2024
Resolved 23 April 2024
Resolution: Received technician report following fire alarm system panel install and system testing. Tests were satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 April 2024
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 30 June 2024 — due date passed with no resolution recorded
Resolution: Temporary repairs are regularly checked and show no signs of failing. Def extended until end of season.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precautions against hazards that might endanger the vessel and the person being transported. Vessel is authorized to proceed to St. Ignace, MI under reduced propulsion utilizing the port engine without any passengers on board. Vessel shall have a second company vessel along side available and equipped to assist in towing evolution if required. Vessel shall conduct repairs and provide inspection/testing to the satisfaction of the local OCMI prior to departure from St. Ignace, MI. Vessel shall keep local OCMI informed of any changes in propulsion capabilities during transit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2023
Resolved 1 September 2023
Resolution: MDE repaired & operationally tested. CID cleared vessel to oeprate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Starboard MDE experienced inconsistent RPMs, rendering it inoperable. Conduct causal analysis and complete permanent repairs to the satisfaction of attending CG marine inspectors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2023
Resolved 26 June 2023
Resolution: Michigan Cat Technicians completed causal analysis and permanent repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2023
Resolved
Install protective covers to electrical terminals in battery storage closet and cleaning closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 April 2023
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2023
Resolved
Vessel material condition found to unsatisfactory for the safe carriage of passengers. No carriage of passengers is allowed until CG MI returns to complete inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2023
Resolved 19 April 2023
Resolution: Vessel condition corrected, def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2023
Resolved
All MDE turbo exhaust lagging is required to be properly tightened and have retaining wire/springs installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2023
Resolved 19 April 2023
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 April 2023
Resolved
Repair cracked welds in port void #1,2,3 & stbd void #1. Submit plans for stbd bow damage, repair accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 31 August 2023
Resolution: permanent repairs completed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 April 2023
Resolved
Both enginerooms overhead insulation must be cleaned and properly installed, all seams must be sealed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2023
Resolved 19 April 2023
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2023
Resolved
Engineroom FFE systems have been serviced however tech report shows time delays released under allowable limits. Re-test with CG MI witness or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2023
Resolved 24 April 2023
Resolution: Port time delay tested sat; stbd time delay replaced & properly tested in my presence.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 August 2022
Resolved
Found guard for the alternator broken in place and resting on the spinning belt. Captain shut down the affected engine and mechanics removed the broken guard. Replace broken guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 31 August 2022
Resolution: replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2022
Resolved
Multiple cracked welds sighted, require repair. Stbd forepeak, port #2 void at chine, stbd qtr ramp & bulwarks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 18 May 2022
Resolution: repaired
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 9 May 2022
Resolved
Uppermost deck seating not safe for passengers, uppermost deck is made inaccessible to passengers. Limited passenger count appropriately.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 18 May 2022
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 May 2022
Resolved
1 IBA found installed incorrectly.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2022
Resolved 9 May 2022
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2022
Resolved
Stbd engineroom aft fire/smoke detector melted, requires replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 1 June 2022
Resolution: replaced, ops tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2022
Resolved
Port engineroom alternator cover missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 9 May 2022
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 May 2022
Resolved
Port engineroom MDE & genset emergency fuel shutoffs inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2022
Resolved 10 May 2022
Resolution: repaired, witnessed operational test, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2021
Resolved
Determine cause and effect permanent repairs to stbd MDE. Demonstrate proepr operatin to attending MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2021
Resolved 16 September 2021
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 July 2021
Resolved
Port steering bucket hydraulic actuator anodes were discovered to be loose and a hazard to possible steering jam/failure.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2021
Resolved 14 July 2021
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 July 2021
Resolved
Repair cracked welds in both port & stbd forepeaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 July 2021
Resolution: corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2021
Resolved
4 fiberglass seats on top deck are cracked & pose a hazard to passengers. Replace or make inaccessible to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 July 2021
Resolution: replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 June 2021
Resolved
The port main has a coolant leak that caused the engine to overheat.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2021
Resolved 2 June 2021
Resolution: Operator sent pictures of permanent repairs
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 May 2021
Resolved
Port forepeak gusset repaired temporarily, permanent repairs required after 2021 operating season.
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 2 May 2022
Resolution: repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Stbd engineroom bilge alarm wiring must be correctly routed through electrical junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 4 November 2020
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 September 2020
Resolved
Install protective device to minimize accidental contact with forwardmost inboard 12 volt light socket in stbd engineroom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 4 November 2020
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2020
Resolved
Repair port MDE oil drain line fitting oil leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 4 November 2020
Resolution: repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2020
Resolved
Repair cracked weld in #2 port side void and 2 cracks in forepeak inboard sponson frame structures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 21 May 2021
Resolution: repaired.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 12 November 2019
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow of the vessel. The vessel name on the stbd bow is illegible. Meet requirements of vessel name markings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 November 2019
Resolved
Master did not have medical card to prove medical qualification. Provide record of medical certificate issued by National Maritime Center.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 November 2019
Resolved
Each vessel must be equipped with at least two operable portable battery lights. The portable light at the operating station is inoperable. Provide operable portable light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 November 2019
Resolved
Vessel must be equipped with public address system. Public address system is inoperable. Comply with requirements for public address system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 November 2019
Resolved
Bilge hand pump is required for spaces forward of collision bulkhead. Hand pump is inoperable. Make hand bilge pump operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 November 2019
Resolved
Most forward port bilge alarm is inoperable. Make this bilge alarm operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 November 2019
Resolved
Each lighting fixture must have a guard or be made of high strength material. Stbd jetroom light does not have a guard. Properly guard this light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 November 2019
Resolved
The installation of portable fire extinguishers must be to the satisfaction of the cognizant OCMI. The stbd forward fire extinguisher on the main deck is not properly secured to the deck or bulkhead. Properly secure this fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 November 2019
Resolved
Compass must be illuminated. Make compass illuminated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 12 November 2019
Resolved
A seat must be constructed to minimize possibility of injury. 30 seats on the most upper deck are broken. Replace these broken seats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 November 2019
Resolved
All observed unsafe practices and hazardous situations must be corrected. The base of the hand rails on the ladderwells to both the 2nd and 3rd decks are cracked. Make these hand rails structurally sound to prevent injury of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 November 2019
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of 2 years after the date on which the unit is installed. 3/4 hydrostatic releases are expired. 1/4 hydrostatic release is not marked with expiration date. Replace the 3 expired hydrostatic releases and properly mark the unmarked hydrostatic release with the correct installation date.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 November 2019
Resolved
In the port forepeak, the weld between the 5th stiffener from the port side and deck is cracked. On the stbd side of the port forepeak, where multiple structures meet, a weld is cracked. Furthermore in the port forepeak, the welds on the stbd side #5,6,7 longitudinal stiffeners are cracked. In the 2nd void aft of the bow on the port side, the weld between the 2nd transverse frame and the port side chine is cracked. 1 crack was found in the stbd fore peak. Repair all cracked welds to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 1 July 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 July 2019
Resolved
unauthorized wire nuts under the helm station and dead-end control wires in several junction boxes, properly dead-end all wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2019
Resolved 1 August 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2019
Resolved
clean and pump port sponson engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2019
Resolved 1 August 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 July 2019
Resolved
Determine cause of loss of propulsion control from stbd bridge "wing" operating station. Effect permanent repairs to the same and provide report to [name withheld]. Repairs shall be made to the satisfaction of the attending Coast Guard Marine Inspector, subject to the following additional provisions:
(a) Vessel is authorized a one-time transit from Mackinac Island to Mackinaw City to facilitate further troubleshooting and repairs.
(b) Complete permanent repairs prior to departure from Mackinaw City.
(c) Demonstrate proper operation of each operating stations main propulsion controls prior to the carriage of passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2019
Resolved 10 July 2019
Resolution: Cleared, see activity narrative.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 October 2018
Resolved
Replace structural fire protection on bulkhead of engine room prior to next operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 20 June 2019
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2018
Resolved
Clean port and starboard engine rooms of exhaust leak soot prior to next operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 20 June 2019
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018
Resolved
The vessel is currently broadcasting (1) Zero Length and Beam, (2) Zero Draft, (2) No Ship type. The Ship should be 60 per the US official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 14 July 2021
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 July 2018
Resolved
Labeling illegible on bilge manifold valves in both enginerooms, to be corrected as per good marine practice.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 August 2018
Resolved 2 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2018
Resolved
Repair exhaust insulation lagging for both main engine to prevent ignition of combustible materials.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2018
Resolved 2 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2018
Resolved
Repairs to the machinery that affect the safety of the
vessel must not be made without the approval of the
cognizant [name withheld] permanent repairs to port engine.
Make available for functional testing both engines
within one (01) week.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2018
Resolved 26 July 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2018
Resolved
It was noted that the vessel only had an expired Certificate of Documentation (COD) on board. Prior a valid COD w/in 30 days to the satisfaction of the OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 26 July 2018
Resolution: this had been verified earlier but not cleared in MISLE.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 June 2018
Resolved
The bridge deck, forward, stbd childsize life jacket storage was labelled twice, once above and below the life jacket storage, however one indicated 15 life jackets, the other 16 life jacket. Properly mark life jacket storage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 8 June 2018
Resolution: Took down incorrect placard.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 4 June 2018
Resolved
Main deck, stbd, forward portable fire extinguisher sign was found falling off the bulkhead due to failing duct tape. Properly mount the fire extinguisher sign on the bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Resolution: Sign was screwed to the bulkhead.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2018
Resolved
The stern navigation light's lens was found to have over sprayed paint on it, which distorts the proper display of the light to other vessels. Make proper repairs to the navigational light prior to operating from dusk to sun rise or during periods of limited visibility.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 4 June 2018
Resolved 5 June 2018
Resolution: Navigation light lens was properly cleaned.
Engineering › Thrusters › Pump
Issued 3 June 2018
Resolved
Vsl sucked bird into jet drive causing loss of propulsion. Make operable propulsion system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2018
Resolution: Jet drive was found fully operational.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 October 2017
Resolved
jet propulsion hydraulic hoses chafed. replace and provide anti-chafe material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 26 July 2018
Resolution: this had been verified earlier but not cleared in MISLE.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 October 2017
Resolved
Engineroomaccess doors must close tightly and be fitted with positive latches. they must be marked with "fire boundary - keep closed"
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 27 December 2017
Resolution: Extended additional 2 weeks on 29NOV per owner request. See email "Documents"
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 October 2017
Resolved
Provide properly serviced PFEs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2017
Resolved 19 October 2017
Resolution: PFEs replaced with properly serviced extinguishers.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 10 October 2017
Resolved
Make repairs to overheating port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2017
Resolved 13 October 2017
Resolution: Unclogged coolant line and replaced inop thermostat.
Communications › Alarms/Indicators › Fire Alarm
Issued 22 August 2017
Resolved
Repair and demonstrate operation of fire alarm strobe light in starboard engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: demonstrated full functionality in my presence
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 August 2017
Resolved
Repair worn/damaged structural fire protection insulation in both engineroom entrances.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: repaired with Promat glue
Documentation › Markings/Placards › Warning Signs
Issued 22 August 2017
Resolved
Provide effective signs or markings in port and starboard engineroom entrances for fire pump control switch, fire damper controls, CO2 pull stations and fire alarm pull stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: all signage appropriately posted in both engineroom accesses.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 22 August 2017
Resolved
Make proper and permanent repairs to main engine cooling system piping, leaks and supports.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2017
Resolved 24 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 22 August 2017
Resolved
Make proper repairs to both main engine exhaust systems to eliminate excessive exhaust leaks and protective insulation to prevent contact with combustible materials.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2017
Resolved 24 August 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 August 2017
Resolved
Remove excessive oily mixtures from bilges in both enginerooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 29 August 2017
Resolution: removed
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 July 2017
Resolved
Due to passenger vessel seating being broken and removed from service, reduce passenger count by 6 persons to 339 total passengers. Make proper repairs to seats to the satisfaction of the attending marine inspector, per 46 CFR 115.112.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 5 July 2017
Resolution: Made proper repairs to the seating.
Electrical › Electric Generation Source (service) › Generator
Issued 3 July 2017
Resolved
Main engine alternators require general maintenance, loose guards and disconnected wiring found during in service inspection. Verified corrected. Owner counselled regarding maintenance shortcomings.
Condition: Improper/Lack of Maintenance
Due 3 July 2017
Resolved 5 July 2017
Resolution: Corrected, per followup visit
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 11 June 2017
Resolved
Prior to operation make permanent repairs to propulsion machinery and demonstrate proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2017
Resolved 15 June 2017
Resolution: Replaced sensor
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 August 2016
Resolved
Provide a Certificate of Documentation that reflects the vesse's current dimensions and tonnage, prior to operating in commercial service in 2017.
Condition: Invalid
Due 15 May 2017
Resolved 7 May 2017
Fire Fighting › Fixed Fire Detection System › Approval
Issued 31 March 2016
Resolved
Existing fire detection system operates satisfactory but is not approved. Submit to the MSC a proposal for approval to install an approved fire detetion and alarm system.
Condition: Improper Installation
Due 27 August 2016
Resolved 26 September 2016
Fire Fighting › Fixed Fire Detection System › Approval
Issued 31 March 2016
Resolved
Complete installation of an approved fire detection and alarm system, meanwhile keep existing unapproved system in operational condition.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 22 August 2017
Resolution: installed & tested in CG presence
Engineering › Non-conventional Propulsion/Steering › Hydraulic Bucket Cylinder (jet)
Issued 21 June 2012
Resolved
Repair and demonstrate proper operations of steering machinery to the satisfaction of the attending marine inspector as per 46 CFR 58.25.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 23 June 2012
Resolution: Repaired and demonstrated proper operations of steering machinery.
Construction/Loadline › Hull › Hull Plating
Issued 15 December 2011
Resolved
Make permanent repairs to freeze-damaged areas in hull and void space beneath port propulsion shaft, prior to operating and before the compliance date. See narrative in issuing activity report.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 April 2012
Resolved 11 April 2012
Resolution: Witnessed 2psig air test of satisfactory repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2008
Resolved
Replace or repair (manufacturer approved) chaffed wiring harness on stbd MDE (fwd, upper bundle).
Condition: Unknown
Due 29 July 2008
Resolved 17 June 2009
Lifesaving › Lifefloat › Serviceable
Issued 29 May 2008
Resolved
Service & repair all (5) lifefloats prior to next operating season.
Condition: Unknown
Due 20 May 2009
Resolved 17 June 2009
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 29 May 2008
Resolved
Make permanent repairs to main deck (bow) fwd access hatch.
Condition: Unknown
Due 29 June 2008
Resolved 17 June 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 31 May 2007
Resolved
Install approved globe on stbd engine room fwd. light.
Condition: Unknown
Due 1 July 2007
Resolved 5 July 2007
Resolution: globe installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2007
Resolved
Replace burnt wiring on aft side of inboard turbo stbd side MDE.
Condition: Unknown
Due 1 July 2007
Resolved 5 July 2007
Resolution: wiring replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 May 2007
Resolved
Install fan shroud on newly installed engine rooms feed fans.
Condition: Improper Installation
Due 1 July 2007
Resolved 5 July 2007
Resolution: fan shroud fabricated and installed
Fire Fighting › Structural - Horizontal Zones › General
Issued 31 May 2007
Resolved
Install tape on OVHD insulation in stbd engine room.
Condition: Unknown
Due 1 July 2007
Resolved 5 July 2007
Resolution: tape installed
Engineering › Fuel Oil Service System › Piping
Issued 31 May 2007
Resolved
Install chaffing gear on stbd engine fuel return line outboard side.
Condition: Unknown
Due 1 July 2007
Resolved 5 July 2007
Resolution: installed chaffing gear
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 31 May 2007
Resolved
Renew stbd engine outboard turbo gasket.
Condition: Unknown
Due 1 July 2007
Resolved 5 July 2007
Resolution: installed new gasket
Electrical › Electrical Distribution System (service) › Cable
Issued 24 May 2006
Resolved
Renew heat-damaged wiring on starboard side overhead of port engine room.
Condition: Damaged By Earlier Event
Due 24 June 2006
Resolved 24 June 2006
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 24 May 2006
Resolved
Label upper deck entranceway with maximum passengers allowed IAW vessel stability letter and 46 CFR 122.602(g).
Due 24 June 2006
Resolved 24 June 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 May 2006
Resolved
Replace in kind, port engine emergency fuel shutoff cable per 46 CFR 119.455 (b) (3).
Condition: Damaged By Earlier Event
Due 24 June 2006
Resolved 26 May 2006
Resolution: Operator installed replacement cable.
Engineering
Issued 28 May 2004
Resolved
Replace bilge alarm in port lazarette.
Condition: Unknown
Due 25 June 2004
Resolved 28 May 2004
Electrical › Lighting (emergency)
Issued 21 August 2002
Resolved
REPAIR STBD ENG RM 12 VOLT LIGHTING SYSTEM. LEGACY COMPONENT DESC: Lighting Branch Circuit
Condition: Unknown
Due 21 September 2002
Resolved 20 September 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 August 2002
Resolved
INSTALL HATCH RETAINERS ON STERN VOID HATCHES PORT AND STBD SIDES.
Condition: Unknown
Due 21 September 2002
Resolved 20 September 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 August 2002
Resolved
INSTALL GUARD ON PORT ENGINE ALTERNATOR. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 21 September 2002
Resolved 20 September 2002
Electrical › Electrical Distribution System (service)
Issued 21 August 2002
Resolved
INSTALL PANEL COVER ON BREAKER BOX, PORT ENGINE ROOM. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Due 21 September 2002
Resolved 29 May 2003
Construction/Loadline › Hull
Issued 21 August 2002
Resolved
REPAIR FRACTURED WELDS STBD PEAK TANK. LEGACY COMPONENT DESC: Weld
Condition: Damaged By Earlier Event
Due 21 September 2002
Resolved 20 September 2002
Engineering › Non-conventional Propulsion/Steering
Issued 23 June 2002
Resolved
Repair stbd waterjet stator fracture as per the manufactures instruction and proivde a copy of the the repair report to the OCMI prior to 10 June 2002.
Condition: Unknown
Due 29 August 2002
Resolved 29 August 2002
Resolution: New stator installed on stbd water jet. All repairs sat.
Construction/Loadline
Issued 25 May 2001
Resolved
Re-install hatch plates in transverse bulkhead between steering compartments and voids prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 28 June 2001
Construction/Loadline
Issued 25 May 2001
Resolved
Prove proper opration of the bilge high level audible alarm prior to carrying passenges and prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 28 June 2001
Lifesaving
Issued 25 May 2001
Resolved
Conduct and log a fire, abandon ship and man-overboard drill prior to the compliance date.
Condition: Unknown
Due 30 May 2001
Resolved 28 June 2001
Fire Fighting
Issued 25 May 2001
Resolved
Provide remote operation for starting the fire pumps at the operating station prior to the compliance date.
Condition: Unknown
Due 25 June 2001
Resolved 3 June 2002
Construction/Loadline
Issued 21 May 1999
Resolved
PROVE PROPER OPERATION OF BILGE HIGH WATER AUDIBLE ALARM PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 21 May 1999
Resolved
REPAIR FIRE PUMP PRESSURE GAUGES FOR PORT AND STARBOARD FIRE PUMP PRIOR TO THE COMPLAINCE DATE.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Construction/Loadline
Issued 21 May 1999
Resolved
REPAIR FRACTURES AS MARKED BY THE ATTENDING MARINE INSPECTOR IN THE PORT AND STARBOARD COMPARTMENTS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 21 May 1999
Resolved
MARK SECOND DECK FOR NOT MORE THAN 110 PERSON AND UPPER DECK FOR NOT MORE THAN 76 PERSONS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 21 June 1999
Resolved 3 June 2002
Construction/Loadline
Issued 23 April 1998
Resolved
Carry no passengers until fractured welds in way of Port and Starboard forepeaks, and #1 Starboard void are renewed.
Condition: Unknown
Due 24 April 1998
Resolved 29 April 1998
Lifesaving
Issued 16 July 1997
Resolved
Replace water light lines, connecting painters, and patch holes on middle life float.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 16 July 1997
Resolved
Re-mark PFD stowage locations.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Fire Fighting
Issued 16 July 1997
Resolved
Install heat detector in starboard engine room and test alarms in both engine rooms to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 6 May 1996
Resolved
Conduct man overboard & abandon ship drills/training. Make log entry IAW 46 CFR 122.520.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Fire Fighting
Issued 6 May 1996
Resolved
Provide affadavit of halon system test/service.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 6 May 1996
Resolved
Repair fractured welds in #1 compt, port and stbd.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Navigation
Issued 6 May 1996
Resolved
Install durable VHF emergency broadcast placard adjacent to all radiotelephone sets IAW 46 CFR 121.506.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 9 May 1995
Resolved
Repair fractured weld on shell longitudinal, starboard fore peak.
Condition: Unknown
Due 9 June 1995
Resolved 19 May 1995
Construction/Loadline
Issued 9 May 1995
Resolved
Repair fracture in shell longitudinal, port fore peak.
Condition: Unknown
Due 9 June 1995
Resolved 19 May 1995
Construction/Loadline
Issued 12 February 1992
Resolved
MAKE NECESSARY REPAIRS TO FORWARD PORTWSIDE MAIN ENGINE SEA VALVE RUBBER INSERT.
Condition: Unknown
Due 12 February 1992
Resolved 12 February 1992
Navigation
Issued 12 February 1992
Resolved
ADD WASHER TO PORT RUDDER HYDRAULIC CYLINDER UPPER PIN.
Condition: Unknown
Due 12 February 1992
Resolved 12 February 1992
Construction/Loadline
Issued 12 February 1992
Resolved
MAKE NECESSARY REPAIRS TO AFT SEA VALVE, PORTSIDE, HANDLE.
Condition: Unknown
Due 12 February 1992
Resolved 12 February 1992