Records from 1987 to 2026. Most recent: inspection, 7 May 2026.
Inspection history · 62
7 May 2026
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8368520
3 October 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8244035
19 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8138964
20 June 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7938505
13 May 2024
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7911185
2 July 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7728825
19 June 2023
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7718692
19 May 2023
Annual Inspection · DAPI Audit · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7692021
27 June 2022
Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7489638
10 May 2019
Deficiency Check · Internal Structural Exam · COI Inspection · Plan Review "T" Boat · Hull Examination · Administrative Inspection · Examination of Repairs · DAPI Audit · Inclining Experiment · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6681141
27 January 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6081060
30 September 2016
Examination of Repairs · Damage Survey · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6013291
16 October 2015
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5233349
27 October 2014
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5013009
27 July 2012
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4396559
24 August 2011
Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4127432
23 May 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3214407
14 September 2007
Internal Structural Exam · Hull Examination · Damage Survey · Examination of Repairs · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3057533
9 January 2007
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2854701
12 October 2006
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2799221
25 May 2006
Re-Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2658484
6 December 2005
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2543315
13 October 2004
Damage Survey · Internal Structural Exam · Construction Oversight · Hull Examination · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2148778
15 July 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2133971
5 December 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1959533
20 November 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1951779
7 February 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1741288
3 February 2003
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1739157
16 October 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1688446
14 January 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1481860
24 January 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410462
21 October 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1469606
28 May 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802365
27 May 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802287
22 December 1998
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465445
30 December 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372074
14 August 1997
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371985
8 August 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 106075
31 October 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371567
10 October 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390360
19 August 1996
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1092191
4 May 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 122834
23 September 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 70501
31 July 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380259
11 August 1994
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 864919
29 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 66467
11 June 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1147564
8 June 1993
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 838758
20 May 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841471
23 April 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841437
14 December 1992
Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1140991
1 October 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 957569
30 May 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 943593
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1251427
1 April 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1235354
28 January 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917907
5 December 1990
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911709
17 April 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 913442
6 April 1989
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1349140
6 January 1989
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1197405
21 December 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005424
22 July 1987
Plan Review "T" Boat · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1028573
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2026
Resolved
A fire pump must be capable of both remote operation from the operating station and local operation at the pump. The fire pump control from the operating station does not operate pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2026
Resolved 8 May 2026
Resolution: control switch replaced. system operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026
Resolved
The general construction of the vessel shall be such as to minimize fire hazards. The wiring located in the electrical closet through the deck into the engine space is not properly sealed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2026
Resolved 4 June 2026
Resolution: Deck penetrations for electrical cables have been sealed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation in the space protected. The fan installed on the starboard, forward, engine room bulkhead does not shutdown when the pre-engineered fixed gas system is activated. Repair or remove the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 20 June 2024
Resolution: Witnessed operational test of powered ventilation fan automatic shutdown upon activation of the pre-engineered fire extinguishing system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Electrical equipment on a vessel muste be installed and maintained to protect persons from shock. The shore tie receptacle is damaged, not allowing a complete connection. Make repairs to the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 25 June 2024
Resolution: Inspected new shore tie receptacle on stern.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 June 2023
Resolved
Vessel reported starboard transmission failure during a cruise on 18 JUN and safely moored to disembark passengers. Vessel plans to haul out on 20 JUN at Marine Services to make repairs. A vessel must be operated in accordance with applicable laws and regulations. Prior to carrying passengers, contact the MSU Chicago Inspections Division to clear this requirement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2023
Resolved 2 July 2023
Resolution: Vessel has rebuilt transmission, replaced dripless shaft seal and dampner plate, and conducted sea trials.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 May 2023
Resolved
Each hatch cover on an open deck must be attached to the hatch frame or coaming with chains or other devices to prevent loss. The deck hatch to the forepeak is missing the captive chain. Install the same.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Hatch cover is now attached to vessel frame via chain.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 19 May 2023
Resolved
Ensure the passenger safety orientation contains all the information required by 46 CFR 185.506.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 12 June 2023
Resolution: Passenger orientation received/reviewed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2023
Resolved
Permanently mount the power strip located under the steering console in the pilot house.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Power strip as been permanently mounted.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2023
Resolved
Remove the extension cords for the freezer in the galley and refers behind the main deck bar.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Extension cords for the freezer in the galley and refers behind the main deck bar have been removed and permanent cable installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023
Resolved
Provide donning placards for each type of Type I lifejacket provided onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Donning placards for each type of Type I lifejacket onboard have been posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2023
Resolved
Portable fire extinguishers must be checked by the crew monthly and logged. Conduct monthly inspections on all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023
Resolved
Waste receptacles must be contructed of non-combustible materials remove all combustible waste receptacles from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Waste receptacles are of non-combustible materials now.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2022
Resolved
Forepeak, P/W Space, Fuel Hold, Mechanical Room, and Engine Room have cable runs that need excessive lengths (loops) shortened and supported with metal at least every 24" to the satisfaction of local OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: These spaces have completed shortening cable excessive lengths (loops) and supported with metal at least every 24".
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 April 2022
Resolved
Forepeak: Install new gasket for space main deck flush hatch to local OCMI satisfaction.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 16 May 2022
Resolution: Forepeak hatch gasket has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2022
Resolved
P/W Space: Aft WTB on starboard upper side has flood alarm cable going through WTB without stuffing tube. Install stuffing tube and seal to local OCMI satisfaction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Stuffing tube for through WTB flooding calbe has been installed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 April 2022
Resolved
Alarm testing for propulsion engines and genset need to be conducted in presence of [name withheld] what alarms and setpoints are in place for each engine and genset.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 27 June 2022
Resolution: Conducted alarm testing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 April 2022
Resolved
Fire boy system needs complete but simple instruction for operation posted at remote pull station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 23 May 2022
Resolution: Simple complete instructions were installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 April 2022
Resolved
Provide evidence of Great Lakes Radio Agreement for year completed.
47 CFR 80.951
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
Resolution: Received evidence that vessel completed inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2022
Resolved
Mechanical Room: Electric F/P stuffing tube for cable entry is not properly sized and conductors are exposed. Provide proper sized/fit stuffing tube for cable entry.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Suitable stuffing tube size has been installed, conductors are no longer exposed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2022
Resolved
Install new approved vari nozzle for fire hose station when it arrives.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Approved vari nozzle arrived and was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 28 April 2022
Resolved
Engine Room: Install rotating machinery guard for mechanical F/P system on port engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Rotating machinery guard has been installed for mechanical F/P system on port engine.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2022
Resolved
Air Receiver Room: Seal up all holes and through WTB penetrations in space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: WTB penetrations have been sealed.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 30 September 2016
Resolved
Crop and renew the deck in the starboard head. Access to the starboard head is to be closed off from passengers until repairs are completed.
Due 27 December 2016
Resolved 30 December 2016
Resolution: Repaired satisfactorily.
Construction/Loadline › Structures › Door
Issued 30 September 2016
Resolved
Crop and renew wasted area (approx 4") on the port and starboard thresholds in way of the forward doors.
Due 27 December 2016
Resolved 30 December 2016
Resolution: Repaired satisfactorily.
Fire Fighting › Fire Main › Condition
Issued 27 July 2012
Resolved
Fire main piping inside engine compartment and next compartment forward is wasted and has holes approx. 1/2" in two spots. Vessel restricted from carrying passengers until permanent repairs made.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2012
Resolution: Verified installation of new piping. Witnessed satisfactory operation of fire main system.
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 July 2012
Resolved
Place life jacket donning placards in conspicuous locations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 2 August 2012
Resolution: Placards posted.
Engineering › Bilge Water Management System › Strainer
Issued 27 July 2012
Resolved
Bilge suction strainer missing in engine compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 2 August 2012
Resolution: Verified installation of strainer.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 27 July 2012
Resolved
Raw water hose to generator is beginning to deteriorate.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 2 August 2012
Resolution: Hose replaced.
Engineering › Bilge Water Management System › Hose
Issued 27 July 2012
Resolved
In #2 compartment (fwd of engine comp.), bilge suction hose is chaffed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 22 August 2012
Resolution: Hose replaced.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 July 2012
Resolved
Fuel tank missing grounding straps for flex hose connections at tank and fill.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 2 August 2012
Resolution: Grounding straps installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 July 2012
Resolved
Ensure all bilge high level alarms are mounted to deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 22 August 2012
Resolution: Bilge high level alarms mounted to deck.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 27 July 2012
Resolved
Replace hatch seal for forepeak.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 22 August 2012
Resolution: Seal replaced.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 27 July 2012
Resolved
Engine oil pressure gauge for port engine inop.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 22 August 2012
Resolution: Gauge replaced and tested sat.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 27 July 2012
Resolved
Low level oil alarm for stbd engine inop.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 22 August 2012
Resolution: Alarm replaced.
Engineering › Fuel Oil Service System › Valve
Issued 1 May 2008
Resolved
Provide a fuel shutof valve in the fuel line near each engine.
Due 1 June 2008
Resolved 23 May 2008
Resolution: Item installed.
Construction/Loadline › Hull › Bottom Plating
Issued 14 September 2007
Resolved
Sand blast the hull from the Rub Rails and below. Present a repair proposal for all areas below minimum scantlings. All remaining plate must be gauged
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 21 September 2007
Resolution: Hull sandblasted. Major repairs in progress.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 9 January 2007
Resolved
Permanently display vessel
Due 9 February 2007
Resolved 9 February 2007
Resolution: Name and homeport painted on the stern.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 9 January 2007
Resolved
Double clamp all water lines on the 2 MDE's and generator.
Due 9 February 2007
Resolved 9 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 9 January 2007
Resolved
Repair oil leaks on the generator.
Due 9 February 2007
Resolved 9 February 2007
Resolution: Item corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 9 January 2007
Resolved
Repair exhaust leak on the starboard MDE.
Due 9 February 2007
Resolved 9 February 2007
Resolution: Item corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 9 January 2007
Resolved
Place guards on the turining machinery on the 2 MDE's and generator.
Due 9 February 2007
Resolved 9 February 2007
Resolution: Item corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 January 2007
Resolved
Renew reflective tape on 16 life Jackets.
Due 9 February 2007
Resolved 9 February 2007
Resolution: Item corrected.
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 October 2006
Resolved
Make permanent repairs to the vent outlets in compartments one, two, three and four.
Due 28 February 2007
Resolved 1 May 2008
Resolution: Permanent repairs made.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 30 November 2005
Resolved
Provide 2 additional orange day smokes.
Due 13 December 2005
Resolved 25 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 November 2005
Resolved
Provide a complete "First Aid Kit" as required by 46 CFR 184.710 and 160.041.
Due 6 January 2006
Resolved 25 May 2006
Stability › Watertight Integrity › General
Issued 30 November 2005
Resolved
Make permanent repairs to the Forward Peak stbd vent.
Due 13 October 2006
Resolved 25 May 2006
Construction/Loadline › Hull › Bottom Plating
Issued 13 October 2004
Resolved
Prior to operating vessel, make repairs to hull structure for all areas below scantlings.
Due 29 September 2006
Resolved 6 December 2005
Resolution: Item administratively cleared.
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2003
Resolved
Crop and renew as original wasted hull plating on stbd side embarkation station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2003
Resolved 12 February 2003
Resolution: Repairs made and tested sat.
Engineering › Bilge Water Management System
Issued 16 October 2002
Resolved
INSTALL FOOT VALVE AND STRAINER ON BILGE PIPING IN WATER TANK ROOM IAW 46 CFR 182.510. LEGACY COMPONENT DESC: Strainer
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2002
Resolved 16 October 2002
Resolution: Received a fax receipt of purchase of new bilge foot.
Lifesaving
Issued 30 December 1997
Resolved
Provide 1 fully supplied first aid kit._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Navigation
Issued 30 December 1997
Resolved
Provide and post one VHF emergency placard
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997
Resolved
Install a blank on the unused suction line above the thru hull fitting, which located in the fire pump hold
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Engineering
Issued 14 August 1997
Resolved
Provide a copy of the Volvo technician report, of the cause of the leaking to the starboard propulsion unit, and repair as reccomended.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Documentation
Issued 31 October 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Lifesaving
Issued 31 October 1996
Resolved
Attach retro-reflective tape to life rings
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Engineering
Issued 31 October 1996
Resolved
Properly Label Emergency Fuel Shutoff Valve.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Construction/Loadline
Issued 31 October 1996
Resolved
Label bilge manifold
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Accommodation/Occupational Safety
Issued 23 April 1993
Resolved
PROPERLY SECURE IN PLACE THE STOVE AND REFRIGERATOR IN THE GALLEY COMPARTMENT.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Documentation
Issued 23 April 1993
Resolved
PROVIDE EVIDENCE OF COMPLYING WITH THE REQUIREMENTS IN 46 CFR 16 FOR CHEMICAL DRUG TESTING OF THE CREW, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Fire Fighting
Issued 23 April 1993
Resolved
CONDUCT EMERGENCY DRILLS FOR MAN OVERBOARD AND FIRE AT SEA TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Construction/Loadline
Issued 23 April 1993
Resolved
INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3 PRIOR TO COMPLETION OF THE NEXT ROUTINE DRYDOCKING.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Accommodation/Occupational Safety
Issued 23 April 1993
Resolved
PROPERLY WIRE STOVE IN GALLEY COMPARTMENT AND PROVIDE INSTALLATION PLANS FOR PLAN REVIEW TO COAST GUARD.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Engineering
Issued 23 April 1993
Resolved
PROVE PROPER OPERATION OF THE PORT ENGINE OUTDRIVE INDICATOR LOCATED IN THEWHEELHOUSE.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Documentation
Issued 23 April 1993
Resolved
PROVIDE VALID FCC RADIO STATION AND FCC SAFETY EQUIPMENT CERTIFICATES FOR VESSEL.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Engineering
Issued 23 April 1993
Resolved
RENEW FLAME SCREEN ON THE PORTSIDE DIESEL FUEL TANK VENT.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Construction/Loadline
Issued 30 May 1992
Resolved
MAKE PERMANENT REPAIRS IN KIND AS ORIGINAL IN WAY OF THE TEMPORARY REPAIRS MADE TO THE KEEL, FRAMES, STIFFENERS AND SHELL PLATES IN WAY OF THE FORWARDPEAK TANK AND AFT OF THE COLLISION BULKHEAD. TO BE COMPLETED NO LATER THANNEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 30 May 1992
Resolved 30 May 1992
Unknown
Issued 30 May 1992
Resolved
PROVIDE DOCUMENTATION OF USING A CHEMICAL DRUG TESTING PROGRAM THAT COMPLIES WITH 46 CFR 16 SUBPART B.
Condition: Unknown
Due 30 May 1992
Resolved 30 May 1992
Electrical
Issued 30 May 1992
Resolved
SECURE PROPERLY THE WIRING LOCATED BELOW THE MAIN DECK AND REPLACE WIRE NUTS WITH PRESSURE OR CRIMP-TYPE CONNECTORS IN WAY OF THE PILOT HOUSE.
Condition: Unknown
Due 30 May 1992
Resolved 30 May 1992
Construction/Loadline
Issued 5 December 1990
Resolved
PROVIDE ACCESS TO FOREPEAK.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
PROVIDE ADEQUATE HOSES FOR HAND PUMP TO PUMP BILGES OVERBOARD PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Documentation
Issued 5 December 1990
Resolved
PROPERLY MARK P & S BOW WITH VESSEL'S NAME (MIN. 4" CONTRAST COLORED LETTERS).
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
INSTALL MOUNTING BOLTS FOR FIRE PUMP SEA STRAINER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
CORRECT PROBLEM OF PORT MAIN ENGINE MORSE CONTROLS RUBBING ON STEERING LINKAGE PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Navigation
Issued 5 December 1990
Resolved
REPAIR MOUNTING OF STEERING RAM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
REPLACE GEN. EXH. HOSE FROM ENGINE TO MUFFLER AND REPAIR LEAK AT MUFFLER OUTLET (WATER LEAKS).
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Documentation
Issued 5 December 1990
Resolved
PROVIDE GARBAGE MANAGEMENT PLAN.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Navigation
Issued 5 December 1990
Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Documentation
Issued 5 December 1990
Resolved
PROVIDE A VALID FCC RADIO TELELPHONY CERTIFICATE PRIOR TO OPERATING MORE THAN 1000' FROM LAND.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 17 April 1990
Resolved
REPLACE OUTDATED DISTRESS FLARES, 6 RED AND 6 ORANGE SMOKE, WITH FLARES THAT HAVE NOT REACHED THEIR EXPIRATION DATE.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Engineering
Issued 17 April 1990
Resolved
MAKE PERMANENT REPAIRS TO REMOTE FUEL SHUTOFF PULL STATION, LOCATED ON MAINDECK PORT SIDE OF MAIN PASSENGER PARLOR.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Fire Fighting
Issued 6 January 1989
Resolved
SERVICE ALL FIRE EXTINGUISHERS, PROVIDE DOCUMENTATION TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Construction/Loadline
Issued 6 January 1989
Resolved
RENEW PORT WINDOW ON MAIN DECK WHERE BROKEN. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Documentation
Issued 22 July 1987
Resolved
PROVIDE FCC LICENSE FOR VHF RADIO.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987
Documentation
Issued 22 July 1987
Resolved
POST STABILITY LETTER IN PILOT HOUSE WHEN RECEIVED FROM MSO ST. LOUIS, MO.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987