MAURY USCG vessel records
← All vessels

ENCHANTMENT

Built
1987
Last inspected
7 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9147
284470
Flag
UNITED STATES
Maury page id
psix-284470

Documentation record

Registered dimensions (L × B × D)70.0 ft × 18.0 ft × 4.9 ft
Registered tonnagegross 39 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LACROSSE, WI, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 21 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

7 May 2026 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8368520
3 October 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8244035
19 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8138964
20 June 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7938505
13 May 2024 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7911185
2 July 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7728825
19 June 2023 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7718692
19 May 2023 Annual Inspection · DAPI Audit · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7692021
27 June 2022 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7489638
10 May 2019 Deficiency Check · Internal Structural Exam · COI Inspection · Plan Review "T" Boat · Hull Examination · Administrative Inspection · Examination of Repairs · DAPI Audit · Inclining Experiment · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6681141
27 January 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6081060
30 September 2016 Examination of Repairs · Damage Survey · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6013291

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2026 Resolved
A fire pump must be capable of both remote operation from the operating station and local operation at the pump. The fire pump control from the operating station does not operate pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2026
Resolved 8 May 2026
Resolution: control switch replaced. system operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2026 Resolved
The general construction of the vessel shall be such as to minimize fire hazards. The wiring located in the electrical closet through the deck into the engine space is not properly sealed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2026
Resolved 4 June 2026
Resolution: Deck penetrations for electrical cables have been sealed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation in the space protected. The fan installed on the starboard, forward, engine room bulkhead does not shutdown when the pre-engineered fixed gas system is activated. Repair or remove the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 20 June 2024
Resolution: Witnessed operational test of powered ventilation fan automatic shutdown upon activation of the pre-engineered fire extinguishing system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024 Resolved
Electrical equipment on a vessel muste be installed and maintained to protect persons from shock. The shore tie receptacle is damaged, not allowing a complete connection. Make repairs to the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 25 June 2024
Resolution: Inspected new shore tie receptacle on stern.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 June 2023 Resolved
Vessel reported starboard transmission failure during a cruise on 18 JUN and safely moored to disembark passengers. Vessel plans to haul out on 20 JUN at Marine Services to make repairs. A vessel must be operated in accordance with applicable laws and regulations. Prior to carrying passengers, contact the MSU Chicago Inspections Division to clear this requirement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2023
Resolved 2 July 2023
Resolution: Vessel has rebuilt transmission, replaced dripless shaft seal and dampner plate, and conducted sea trials.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 May 2023 Resolved
Each hatch cover on an open deck must be attached to the hatch frame or coaming with chains or other devices to prevent loss. The deck hatch to the forepeak is missing the captive chain. Install the same.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Hatch cover is now attached to vessel frame via chain.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 19 May 2023 Resolved
Ensure the passenger safety orientation contains all the information required by 46 CFR 185.506.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 12 June 2023
Resolution: Passenger orientation received/reviewed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2023 Resolved
Permanently mount the power strip located under the steering console in the pilot house.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Power strip as been permanently mounted.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2023 Resolved
Remove the extension cords for the freezer in the galley and refers behind the main deck bar.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Extension cords for the freezer in the galley and refers behind the main deck bar have been removed and permanent cable installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2023 Resolved
Provide donning placards for each type of Type I lifejacket provided onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Donning placards for each type of Type I lifejacket onboard have been posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2023 Resolved
Portable fire extinguishers must be checked by the crew monthly and logged. Conduct monthly inspections on all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023 Resolved
Waste receptacles must be contructed of non-combustible materials remove all combustible waste receptacles from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2023
Resolved 7 June 2023
Resolution: Waste receptacles are of non-combustible materials now.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2022 Resolved
Forepeak, P/W Space, Fuel Hold, Mechanical Room, and Engine Room have cable runs that need excessive lengths (loops) shortened and supported with metal at least every 24" to the satisfaction of local OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: These spaces have completed shortening cable excessive lengths (loops) and supported with metal at least every 24".
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 April 2022 Resolved
Forepeak: Install new gasket for space main deck flush hatch to local OCMI satisfaction.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 16 May 2022
Resolution: Forepeak hatch gasket has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2022 Resolved
P/W Space: Aft WTB on starboard upper side has flood alarm cable going through WTB without stuffing tube. Install stuffing tube and seal to local OCMI satisfaction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Stuffing tube for through WTB flooding calbe has been installed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 April 2022 Resolved
Alarm testing for propulsion engines and genset need to be conducted in presence of [name withheld] what alarms and setpoints are in place for each engine and genset.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 27 June 2022
Resolution: Conducted alarm testing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 April 2022 Resolved
Fire boy system needs complete but simple instruction for operation posted at remote pull station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 23 May 2022
Resolution: Simple complete instructions were installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 April 2022 Resolved
Provide evidence of Great Lakes Radio Agreement for year completed. 47 CFR 80.951
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
Resolution: Received evidence that vessel completed inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2022 Resolved
Mechanical Room: Electric F/P stuffing tube for cable entry is not properly sized and conductors are exposed. Provide proper sized/fit stuffing tube for cable entry.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Suitable stuffing tube size has been installed, conductors are no longer exposed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2022 Resolved
Install new approved vari nozzle for fire hose station when it arrives.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Approved vari nozzle arrived and was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 28 April 2022 Resolved
Engine Room: Install rotating machinery guard for mechanical F/P system on port engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: Rotating machinery guard has been installed for mechanical F/P system on port engine.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2022 Resolved
Air Receiver Room: Seal up all holes and through WTB penetrations in space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 16 May 2022
Resolution: WTB penetrations have been sealed.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 30 September 2016 Resolved
Crop and renew the deck in the starboard head. Access to the starboard head is to be closed off from passengers until repairs are completed.
Due 27 December 2016
Resolved 30 December 2016
Resolution: Repaired satisfactorily.
Construction/Loadline › Structures › Door
Issued 30 September 2016 Resolved
Crop and renew wasted area (approx 4") on the port and starboard thresholds in way of the forward doors.
Due 27 December 2016
Resolved 30 December 2016
Resolution: Repaired satisfactorily.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.