Records from 1987 to 2026. Most recent: inspection, 9 April 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2026
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. Vessel's installed bilge pumping arrangement using engine driven pump was incapable of taking suction from the engine room compartment due to a cracked hose. Additionally, another hose on the system on the pump is showing signs of external deterioration (cracking), requiring replacement. 46 CFR 182.25-1 (Old T)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2026
Resolved 27 April 2026
Resolution: Hoses in bilge system replaced and tested.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 April 2026
Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel's stability letter on board was out-of-date and had been superseded by a newer stability letter dated 21APR2025 referenced by the COI. 46 CFR 176.306
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 27 April 2026
Resolution: Current stability letter verified onboard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 9 April 2026
Resolved
The shutoff valve at the fuel tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Fuel oil tank shutoffs on the starboard forward and aft in the engine room were incapable of full closure.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 9 April 2026
Resolution: Master made changes to the clamping arrangement and fixed both fuel closure devices. Tested Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2024
Resolved
A flame shield is required for a marine type fuel strainer with a bowl of other than steel constrution. Starboard fuel strainer is missing flame shield. 46CFR182.455(b)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 15 January 2025
Resolution: installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2024
Resolved
Each small battery installation must be protected from falling objects. Starboard battery box is missing cover. 46CFR183.354(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 15 January 2025
Resolution: installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 August 2024
Resolved
Fastenings of each vessel must provide for safe operation with consideration given to the provision of a seaworthy hull. Starboard rudder post is leaking. 46CFR177.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 23 April 2025
Resolution: backing plate was cracked. Renewed backing plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2024
Resolved
Machinery must be maintained in such a manner as to afford adequate protection against machinery failure. Both main propulsion engine exhaust piping systems are leaking water. 46CFR182.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 23 April 2025
Resolution: installed new FRP exhaust tubes
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024
Resolved
Provide tech report attesting to integrity of stbd fuel line where battery cable grounded.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: fuel line repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2024
Resolved
Repair/renew any affected wiring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: wiring renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024
Resolved
Renew damaged fuel line on port MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: fuel hoses renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2024
Resolved
Ensure spent fire extinguishers are recharged/renewed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: rcvd report from technician
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2023
Resolved
All machinery must be installed and maintained in such a
manner as to afford adequate protection against machinery failure. Vessel reported loss of propulsion. Provide cause and repair for CG review and approval.
Action required: 10 - Deficiency Rectified
Resolved 10 August 2023
Resolution: Operator repaired cable mount bracket on port engine and demonstrated satisfactory operation of both engines to attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 January 2023
Resolved
All additional fire and safety requirements for overnight passengers have been implemented with the exception of the following categories: Watchkeeping, Training, Egress, Hazardous items. The vessel is restricted from carrying overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector. An op-control was opened.
Action required: 705 - Other - as specified
Resolved 9 August 2023
Resolution: The vessel is restricted from carrying more than six (6) overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 August 2022
Resolved
An adult life jacket must be provided for all persons. One (1) jacket was missing. Total passenger carriage allowance reduced by one (1) for a total of 47.
Action required: 705 - Other - as specified
Resolved 1 September 2022
Resolution: One adult PFD provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2022
Resolved
Fuel lines and filters provided with valves for removing water must be fitted with caps or plugs to prevent fuel leakage. The generator fuel strainer peacock valve is missing the cap or plug.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: plug provided
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 August 2022
Resolved
A high-water level indicator must be installed in spaces with through-hull fittings. The high level switch located in the lazarette space is in-operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: tested laz high water alarm, sat
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 August 2022
Resolved
All radiotelephones must contain integral GPS capabilities or must be connected to an electronic position-fixing device. Also, all radios must have the MMSI internally programmed. One radio has the incorrect MMSI and one radio needs to be connected to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: verified MMSI number in radio and gps in other radio
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 August 2022
Resolved
Marine Employers must ensure all crewman are enrolled in a Chemical Testing Program. The vessel does not have an updated Consortium letter with the company name and all enrolled crewman.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: letter onboard
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 August 2022
Resolved
Inspection and testing of all fire protection equipment must be serviced in accordance with NFPA. The 2022 annual third party servicing report was not provided for USCG review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: servicing report onboard
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 16 August 2022
Resolved
Operators must prevent the discharging of untreated sewage by any of the acceptable methods. The portside Type III device discharge valve was found open and all acceptable prevention methods were not met.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 16 August 2022
Resolved 16 August 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 August 2022
Resolved
All additional fire and safety requirements for overnight passengers have been implemented with the exception of the following categories: Watchkeeping, Training, Egress, Hazardous items. The vessel is restricted from carrying overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector. An op-control was opened.
Action required: 705 - Other - as specified
Resolved 7 November 2022
Resolution: The vessel is restricted from carrying overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 May 2021
Resolved
Show proof that the vessel smoke detection units are in good working order throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2021
Resolution: verified satisfactory
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 May 2021
Resolved
Properly label all areas of means of escape in the accomodation & exit on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2021
Resolution: installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2021
Resolved
Provide guards or an effective means of preventing crew from rotating machinery in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 May 2021
Resolved
Secure wiring in engine room overhead with metal clamps spaced no more than 24" apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: installed
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 May 2021
Resolved
Provide proof that the vessel has valid FCC radio certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: renewed
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 10 May 2021
Resolved
Vessel needs to post the emergency instruction list for passengers to view.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: posted
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
Replace all expired medicines found in the required first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 November 2020
Resolved
Approximate 5" crack, 3' above the waterline resulted from another vessel alliding with RAINISONG's port side, just aft of amidships. Make temporary repairs to the crack to prevent the intrusion of water to the satisfaction of Marine Inspector. In addition, test all high water alarms, bilge pumps, and conduct frequent rounds of internal spaces for water intrusion. Make permanent repairs at next drydock.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 9 November 2020
Resolution: Vessel made temporary repairs to the 5" crack using epoxy. Vessel in transit to Homer, AK for drydock. Notified MSD [name withheld] who will be attending.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 August 2020
Resolved
Light fixtures to have a guard or configured in a way to protect from a strike or impact. 01 light fixture was found to have no protection in the engine room.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep found the protective guard and re-installed around the light. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 August 2020
Resolved
All spaces that require a bilge pump shall be configured to have bilge pumps operate in auto and manual modes with a visual indicator showing operation in each mode.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Deckhand found loose bilge pump wiring connection for manual mode in engine room. Made on the spot repairs and tested bilge pump in both auto and manual mode. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 August 2020
Resolved
Vessel required to carry distress signals for the intended route and service. Expired flares were found onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep procured new flares to replace the ones found expired. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 August 2020
Resolved
Vessel to have a complete set of first aid equipment and medicine required for passenger operations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep procured new medicine to replace the expired medicines found onboard. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020
Resolved
Vessel to have its three fire buckets properly stenciled with lanyards attached to the handle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep stenciled "Fire Bucket" and attached lanyards to the handle that will reach the water line. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 September 2019
Resolved
Repair fiberglass hull damage on port aft corner
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 7 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2019
Resolved
All cable and wire must be installed with metal supports every 24 inches
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 7 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019
Resolved
Make permanent repairs to starboard railing and tighten down port railing bases
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 20 August 2020
Resolution: The starboard railing and port railing bases were properly secured to the base.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 13 September 2019
Resolved
Make permanent repair to port sewage tank
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 7 October 2019
Resolution: aluminum tank replaced with plastic one
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 August 2019
Resolved
Ensure fan in ER is secured while vessel is underway until properly connected to pre-engineered fire extinguishing system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 20 August 2020
Resolution: Owner elected to remove the fan. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2019
Resolved
Installed pre-engineered fixed fire extinguishing system is required a manual activation. Correct at next scheduled drydock (30SEP19).
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 7 October 2019
Resolution: New system installed and tested
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 August 2019
Resolved
Port strut, outboard backing plate is leaking water. Repair at next scheduled drydock (30SEP19).
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 7 October 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 August 2019
Resolved
Port rudder post leaks excessively. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 7 October 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 August 2019
Resolved
Fixed system was in over ride on bridge. System in ER was disconnected. Required to have system operational and serviced by technician prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2019
Resolution: System connected by fire servicing tech and tested satisfactory.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 August 2019
Resolved
Vessel has two Type III tanks with individual discharge valves. Both valves were open and were not able to be closed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2019
Resolution: Operation test sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 7 August 2019
Resolved
No proof of enrollment in USCG approved random drug testing program for the crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2019
Resolution: Reviewed enrollment form
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 August 2019
Resolved
Water found coming through FRP where stbd shaft log meets hull. Make approved temp repairs until vessel can be hulled out where permanent repairs can be made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2020
Resolution: Verified FRP repairs were conducted on the stbd shaft log where it meets the hull. No active leaking was identified. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 August 2019
Resolved
Original COD not on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 August 2019
Resolved
Waste Management Plan needs updated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 20 August 2020
Resolution: Vessel rep provided an adequate waste management plan. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2019
Resolved
Portable fire extinguisher required on the bridge must be mounted in approved bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 8 August 2019
Resolution: Properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 August 2019
Resolved
Ensure smoke detectors in overnight accommodation spaces are operational. Correct prior to using overnight accommodation spaces.
Action required: 705 - Other - as specified
Resolved 7 October 2019
Resolution: Kiddie Bluetooth connected smoke detectors installed throughout the vessel
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 August 2019
Resolved
Ensure E-lighting in overnight accommodation spaces are operation prior to using overnight accommodation space.
Action required: 705 - Other - as specified
Resolved 7 October 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 August 2019
Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 August 2019
Resolved
No visual alarm for high water alarm in the following spaces: tank room/dry stores, berthing, laz.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 August 2019
Resolved
Label high level alarm spaces at operating spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 August 2019
Resolved
Provide donning placards for PFDs that are onboard and provide launching insttructions for IBA.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
Communications › Radio Communications › EPIRB
Issued 9 May 2018
Resolved
hydrostatic release expired
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2018
Resolved 23 May 2018
Resolution: signed and dated as cleared by [name withheld], CWO4
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2018
Resolved
water in lazerette, need to repair/tighten packing gland, remove water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2018
Resolved 10 May 2018
Resolution: night before demonstrated to CG water was removed in space, tightened gland packing bolt, next day CG checked space for water
Engineering › Fuel Oil Service System › Piping
Issued 21 June 2017
Resolved
Permanently repair fuel piping at aft-port bulkhead of engine room
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 8 May 2018
Resolution: Verified proper repair in fuel piping.
Engineering › Fuel Oil Service System › Valve
Issued 21 June 2017
Resolved
Properly secure and label operation sequence of remote fuel shut off cable for MDEs and Generator
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 21 July 2017
Resolution: corrected satisfactorily
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 June 2017
Resolved
Secure thru-hull valve starboard side aft in engine room that is no longer in use
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 July 2017
Resolution: secured satisfactorily
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 15 June 2017
Resolved
Provide CG-2692 for flooding caused by washdown pump
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 June 2017
Resolution: CG-2692 submitted
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 15 June 2017
Resolved
Prove proper operation of main engines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Resolution: Engines are now starting
Stability › Watertight Integrity › General
Issued 15 June 2017
Resolved
Pump all water out of bilges
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 21 July 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 June 2017
Resolved
Prove proper operation of all bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2017
Resolution: all visual and audible alarms are now operational
Engineering › Bilge Water Management System › Pump
Issued 15 June 2017
Resolved
Prove proper operation of all bilge suction points for fixed bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Resolution: tested all suction points, all sat
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 15 June 2017
Resolved
Tighten packing on shafts to prevent leaking in engine room
Action required: 705 - Other - as specified
Resolved 21 July 2017
Construction/Loadline › Structures › Machinery Space Opening
Issued 15 June 2017
Resolved
Identify and repair holes in bulkheads (between engine room and tank room, also between tank room and space forward)
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 8 May 2018
Resolution: Verified holes in bulkhead have been sealed up.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 26 April 2017
Resolved
Provide working smoke detectors in accommodation space.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 June 2017
Resolution: Smoke detectors now operational
Engineering › Bilge Water Management System › Not Installed
Issued 26 April 2017
Resolved
Secure Rule bilge pumps in engine room and lazarette
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 21 July 2017
Resolution: bilge pumps are now secure
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 April 2017
Resolved
Provide fire servicing certificate showing operational test of fire boy system
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 2 June 2017
Resolution: servicing report received
Engineering › Fuel Oil Service System › Valve
Issued 26 April 2017
Resolved
Replace starboard generator remote fuel valve handle
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 July 2017
Resolution: handle replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2017
Resolved
Install metal supports every 24" on wiring in engine room
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 9 May 2018
Resolution: Received email picture verifying proper metal supports.
Documentation › Certificates/Documents › FCC SSL
Issued 11 May 2016
Resolved
Provide copy of FCC Ship station license
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 25 May 2016
Resolution: Provided copy of FCC license
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 May 2016
Resolved
provide fcc radiotelephony cert
Due 11 May 2016
Resolved 25 May 2016
Resolution: Provided copy of certificate
Documentation › Logs/Records › Drug Test Records
Issued 11 May 2016
Resolved
Provide Alcohol test strips and DAPI enrollment.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Provide strips and DAPI paperwork
Navigation › Piloting/Steering › Marine Charts
Issued 11 May 2016
Resolved
Provide updated Charts, light list and coast pilot
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 8 June 2016
Resolution: Charts and Coast Pilot updated on 25May16. Light List completed 8JUN16.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 May 2016
Resolved
Replace fire brackets on aft deck (2)
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Brackets were replaced
Electrical › Electric Generation Source (service) › Generator Cable
Issued 11 May 2016
Resolved
Connect grounding wired in engine room
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Grounding wires were connected
Documentation › Markings/Placards › Garbage Placard
Issued 11 May 2016
Resolved
Provide garbage placard
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 12 May 2016
Resolution: provided garbage placard
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 May 2016
Resolved
Bilge Alarm must be labeled correctly at operating station for bunkroom.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Bilge alarms labelled correctly
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2016
Resolved
Remove or properly cap dead end wires under helm
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 12 May 2016
Resolution: Capped dead end wires
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 May 2016
Resolved
STBD Aft and FWD in engine room emergency fuel shut offs repaired (2)
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 12 May 2016
Resolution: Repaired both shut off valves
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 May 2016
Resolved
Engine room fire damper needs replaced
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 12 May 2016
Resolution: Replaced damper
Construction/Loadline › Hull › Side Shell
Issued 23 September 2015
Resolved
Make permanent & proper repairs to screw hole in E/R in regard to requirement #10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 November 2015
Resolution: Hole reamed, sanded, cleaned, & filled.
Construction/Loadline › Structures › Deck Plating
Issued 23 September 2015
Resolved
Make weatherdeck available for inspection after coatings removed & prior to applying new coatings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 December 2015
Resolution: Witnessed water test noting no leaks in E/R.
Construction/Loadline › Hull › Hull Plating
Issued 9 September 2015
Resolved
Make permanent & proper repairs to bow IWO stowed anchor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 November 2015
Resolution: Gelcoat & first layer of fiberglass repaired. Plastic wear plate fitted to prevent further bow damage.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 September 2015
Resolved
Install missing & tighten screws to port/stbd side rail door hinges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2015
Resolution: P/S rail door hinges sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 September 2015
Resolved
Install missing & tighten screws to periphery hand rails.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2015
Resolution: Periphery hand rails sat.
Construction/Loadline › Structures › Deck Plating
Issued 9 September 2015
Resolved
Make permanent & proper repairs to deck IWO stbd fuel fills (tripping hazard/failed coating).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2015
Resolution: Old coatings were removed & new coatings applied.
Construction/Loadline › Structures › Deck Plating
Issued 9 September 2015
Resolved
Find source of water & properly seal deck IWO forepeak/anchor rest.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 23 September 2015
Resolution: Anchor rest removed. New sealant applied. No further water ingress observed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 September 2015
Resolved
Clean debris from bilge beneath stbd aft bunk.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 23 September 2015
Resolution: Observed debris removed beneath stbd aft bunk.
Stability › Weathertight Integrity › General
Issued 9 September 2015
Resolved
Make fwd port lights (port/stbd) weathertight (leaking water onto bunks).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 November 2015
Resolution: Port lights re-seated & sealed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 9 September 2015
Resolved
Secure freezer in bunk room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 November 2015
Resolution: Freezer secured to deck.
Construction/Loadline › Structures › Deck Plating
Issued 9 September 2015
Resolved
Make permanent & proper repairs to deck of E/R above port MSD overboard (leaking water).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2015
Resolution: Old coatings removed, new decking installed, & new coatings applied. No water observed leaking into E/R.
Construction/Loadline › Hull › Side Shell
Issued 9 September 2015
Resolved
Rust spot in port E/R on sideshell immediately outboard of fixed fire extinguishing bottle. Clean area & make available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 23 September 2015
Resolution: Rust spot resulted fm unused/failed screw. Issued another requirement to make perm/proper repairs to hole.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 September 2015
Resolved
Install missing screw to exhaust connection to aft stbd bulkhead of E/R.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 23 September 2015
Resolution: Missing screw installed.
Construction/Loadline › Penetrations › Valve Flange
Issued 9 September 2015
Resolved
Make all gate valves ready for inspection (clean up).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 December 2015
Resolution: Observed cleaned gate valves.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 May 2014
Resolved
Prove proper operation of starboard Fireboy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2014
Resolution: Proper operation was demonstrated to the satisfaction of the marine inspector.
Construction/Loadline › Structures › Ventilators
Issued 7 May 2014
Resolved
Make proper repairs to port window in galley/passenger seating area.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 16 May 2014
Resolution: Window was replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 May 2014
Resolved
Replace expired alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2014
Resolution: Current test strips are onboard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 May 2014
Resolved
Provide donning instructions for horse collar life jackets & post same.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 16 May 2014
Resolution: Placard posted.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 May 2014
Resolved
Provide 5 life jackets (CG Approved). Passenger count reduced to 43 until they are obtained.
Action required: 705 - Other - as specified
Resolved 19 May 2015
Resolution: Attended vessel for annual inspection. Identified 23 total lifejackets as compromised. Cleared and re-issued deficiency for 23 lifejackets.
Communications › Visual Communication › Signalling Lamp
Issued 7 May 2014
Resolved
Provide battery for water light. Ensure Battery meets manufacturers specification.
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 16 May 2014
Resolution: Proper battery is installed.
Electrical › Electric Supply System (service) › Battery Charger
Issued 3 July 2012
Resolved
Batteries were not recharging or holding charge and caused the vessel to not be able top restore power upon shut-down.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Resolution: New batteries were installed on the vessel and installation was tested. Caterpillar service report scanned into MISLE.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 7 June 2012
Resolved
Provide proof of FCC Marine Radio Operator Permit.
Due 7 July 2012
Resolved 19 June 2012
Resolution: Verified valid license on FCC webpage.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 7 June 2012
Resolved
Provide proof of negative pre-employment drug test for deckhand.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2012
Resolution: Master faxed in negative results.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 June 2012
Resolved
Double hose clamp water injection lines for exhaust on port and starboard engines.
Due 7 July 2012
Resolved 5 July 2012
Resolution: Double hose clamps installed on both engines.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 June 2012
Resolved
Provide current copy of Coast Guard Light List.
Due 7 July 2012
Resolved 5 July 2012
Resolution: Current copy of area of operation provided.
Construction/Loadline › Penetrations › Gasket
Issued 7 June 2012
Resolved
Seal bilge line penetration in bulkhead of amidships space. Seal penetration in aft bulkhead of amidships space.
Due 7 July 2012
Resolved 5 July 2012
Resolution: Penetrations sealed properly.
Documentation › Certificates/Documents › Stability Letter
Issued 7 December 2011
Resolved
Total persons allowed onboard as per vessels stability letter is reduced to 71utilizing the weight ratio method to comply with the Final Rule that became effective on December 1, 2011. Limitations listed on vessels COI of 50 total persons, of which 48 may be passengers remains in effect. Vessel must submit a COC to the [name withheld] by next annual/COI inspection or be issued a new addendum
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 December 2011
Resolution: Stability Letter Addendum issued for passenger reduction.
Documentation › Certificates/Documents › FCC SSL
Issued 13 May 2009
Resolved
Provide FCC safety certificate
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 22 May 2009
Resolution: FCC certificate provided
Documentation › Certificates/Documents › FCC SSL
Issued 13 May 2009
Resolved
Provide FCC radio operators permit
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 22 May 2009
Resolution: FCC operators permit applied for by operator
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 May 2009
Resolved
Provide current coast pilot
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 22 May 2009
Resolution: Update coast pilot provided
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 May 2009
Resolved
Provide current tables
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 22 May 2009
Resolution: Operator provided current tables
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 April 2008
Resolved
Provide CDO Certificate of Documentation
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 13 May 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 April 2008
Resolved
Provide proof of enrollment in drug & alcohol program
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 April 2008
Resolved
Provide current alcohol test strips
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 13 May 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 April 2008
Resolved
Install sea rails & locking latch on oven in galley
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 13 May 2008
Communications › Radio Communications › EPIRB
Issued 15 April 2008
Resolved
EPIRB registration
Action required: 705 - Other - as specified
Resolved 13 May 2008
Communications › Radio Communications › EPIRB
Issued 15 April 2008
Resolved
Replace expired hydrostatic release on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 April 2008
Resolved
Prove operation of MDE shut-down with installed pre-engineered fire fighting system (Fire-Boy)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2008
Fire Fighting › Structural - B Class Divisions › Main Galleys
Issued 15 April 2008
Resolved
Install B-15 structural fire protection IVO of oven
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 13 May 2008
Engineering › Fuel Oil Service System › Filter
Issued 15 April 2008
Resolved
Install solid type petcocks on fuel filter bowels
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 13 May 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 April 2008
Resolved
Provide crew for drills
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 13 May 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 October 2007
Resolved
Make watertight hydraulic line penetration thru watertight bulkhead in mid-ship compartment.
Action required: 705 - Other - as specified
Due 12 November 2007
Resolved 20 November 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 May 2007
Resolved
Replace Starboard MSD thru-hull gate value
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2007
Resolved 15 May 2007
Construction/Loadline › Hull › Side Shell
Issued 3 May 2007
Resolved
Repair damaged FRP at port transom in lazzerate
Action required: 705 - Other - as specified
Due 3 June 2007
Resolved 15 May 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 May 2007
Resolved
Prove proper operation of fuel shut-offs
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2007
Resolved 15 May 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 May 2007
Resolved
Provide Coast pilot, light list & charts
Action required: 705 - Other - as specified
Due 3 June 2007
Resolved 15 May 2007
Engineering › Bilge Water Management System › Valve
Issued 25 May 2004
Resolved
Remove sluice valve from forepeak or plumb into bilge system
Due 25 June 2004
Resolved 22 May 2006
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 25 May 2004
Resolved
Repair berthing overhead lights
Due 25 June 2004
Resolved 22 May 2006
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 25 May 2004
Resolved
Replace heat detector in Galley
Due 25 June 2004
Resolved 2 June 2004
Resolution: removed stove, detector no longer required
Accommodation/Occupational Safety › Cooking Systems
Issued 25 May 2004
Resolved
Provide sea rails to stove
Due 25 June 2004
Resolved 2 June 2004
Resolution: stove removed
Documentation › Certificates/Documents › FCC SSL
Issued 25 May 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 25 June 2004
Resolved 22 May 2006
Fire Fighting › Combustible Materials › Insulation
Issued 25 May 2004
Resolved
Repair all loose/falling down insulation in ER overhead
Due 25 June 2004
Resolved 2 June 2004
Resolution: removed
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 25 May 2004
Resolved
Repair port Racor flame impingement bowl
Due 25 June 2004
Resolved 22 May 2006
Documentation › Markings/Placards
Issued 25 May 2004
Resolved
Mark hull with correct hailing port LEGACY COMPONENT DESC: Hailing Port
Condition: Improper Installation
Due 25 June 2004
Resolved 2 June 2004
Resolution: done
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 May 2004
Resolved
Locate & correct sourse of water in stbd battery box
Condition: Damaged By Earlier Event
Due 25 June 2004
Resolved 22 May 2006
Engineering › Bilge Water Management System › Pump
Issued 25 May 2004
Resolved
Remove grey water discharge into bilge of fwd berthing
Due 25 June 2004
Resolved 22 May 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 25 May 2004
Resolved
Provide vent covers for natural vent scoops
Due 25 June 2004
Resolved 22 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 May 2004
Resolved
Replace stbd engine oil soaked lagging
Due 25 June 2004
Resolved 10 March 2006
Resolution: Engine replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 May 2004
Resolved
Provide machinery guards P/S MDE's
Due 25 June 2004
Resolved 22 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 May 2004
Resolved
Provide 8A & 2C PFD's- POB limited to 62A/5C until corrected
02JUN: Witnessed 7A/2C PFD's. 1A PFD remains required. POB limit corrected to 69 until corrected.
Due 25 June 2004
Resolved 22 May 2006
Engineering › Fuel Oil Service System
Issued 20 April 2003
Resolved
Properly marked aft port & starboard remote fuel oil shutdown valves. Currently port valve is operated by valve marked stbd and stbd valve is operated by valve marked port.
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Documentation › Certificates/Documents
Issued 14 April 2003
Resolved
Provide current Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Documentation › Certificates/Documents
Issued 14 April 2003
Resolved
Provide current FCC Station License. LEGACY COMPONENT DESC: FCC SSL
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Lifesaving › Inflatable Liferafts
Issued 14 April 2003
Resolved
Provide 50 person liferaft on board vessel. Vessel limited to carrying 20 persons total until this deficiency cleared. LEGACY COMPONENT DESC: Carriage Requirement
Due 7 May 2003
Resolved 1 May 2003
Lifesaving › Hand Flares
Issued 14 April 2003
Resolved
Replace 6 expired red distress signals. LEGACY COMPONENT DESC: Condition
Due 7 May 2003
Resolved 1 May 2003
Lifesaving › Hand Flares
Issued 14 April 2003
Resolved
Unsecure distress signal box from vessel. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 1 May 2003
Lifesaving › Hand Flares
Issued 14 April 2003
Resolved
Mark distress signal box. LEGACY COMPONENT DESC: Marking
Due 7 May 2003
Resolved 1 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 14 April 2003
Resolved
Mark correct vessel name on 12 adult and 2 children's PFD's. LEGACY COMPONENT DESC: Marking
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Lifesaving › Lifejacket/PFD (General)
Issued 14 April 2003
Resolved
Repair snaps on 2 adult PFD's. Vessel is limited to total of 68 total persons until this item is cleared. LEGACY COMPONENT DESC: Condition
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Lifesaving › Lifejacket/PFD (General)
Issued 14 April 2003
Resolved
Provide 2 additional adult PFD's. Vessel limited to 66 total persons until items 8 & 9 corrected. LEGACY COMPONENT DESC: Quantity
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Lifesaving › Lifebuoys
Issued 14 April 2003
Resolved
Attach water light to lifebuoy. LEGACY COMPONENT DESC: Self-igniting Lights
Due 7 May 2003
Resolved 25 June 2003
Resolution: Per phoncon with Josh Ferguson.
Engineering › Bilge Water Management System
Issued 14 April 2003
Resolved
Provide portable bilge pump. LEGACY COMPONENT DESC: Pump
Due 7 May 2003
Resolved 1 May 2003
Communications › Radio Communications
Issued 29 April 2002
Resolved
Replace EPIRB hydrostatic release, Prove proper registration. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Engineering › Bilge Water Management System
Issued 29 April 2002
Resolved
Isolate and repair electrical overload condition in E-room bilge pump. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Fire Fighting › Fixed Fire Detection System
Issued 29 April 2002
Resolved
Replace batteries in smoke alarms, prove proper operation. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 April 2002
Resolved
Repair lube oil leak from stbd MDE turbo intake and re-lag exhaust manifold IAW of leak where saturated. LEGACY COMPONENT DESC: Turbocharger
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Fire Fighting › Fire Pumps
Issued 29 April 2002
Resolved
Prove proper operation of jacuzzi pump (second fire pump as stated by crew) LEGACY COMPONENT DESC: Impeller
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 29 April 2002
Resolved
Prove proper operation of Fireboy audible/visual alarm indicator from both cylinders. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 29 April 2002
Resolved
Prove proper operation of forward fuel tank remote shutdown. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Engineering › Bilge Water Management System
Issued 29 April 2002
Resolved
Label Hi-water alarm for main cabin storage space and label electric bilge pump switch for same space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 1 May 2002
Accommodation/Occupational Safety
Issued 29 April 2002
Resolved
Repair ladder to main cabin storage.
Due 1 May 2002
Resolved 1 May 2002
Operations/Management › Drills/Instruction
Issued 29 April 2002
Resolved
Hold fire and MOB drills in presence of attending marine inspector. LEGACY COMPONENT DESC: Fire & MOB
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 9 October 2002
Resolution: Vessel was away from homeport for remainder of 2002 season operating as a standby vessel for oil platform in Cook Inlet. Notified owner of out req, vessel to be winterized within 2 weeks of this date, cleared req w/o witnessing to close case.
Construction/Loadline
Issued 11 July 2001
Resolved
REMOVE ALL OIL & SOAKED SORBANT PADS FROM ER AND KEEP CLEAN & AWAY FROM BILGE SUCTION STRAINER PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Accommodation/Occupational Safety
Issued 11 July 2001
Resolved
SECURE AFT DECK SEATS PROPERLY PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Accommodation/Occupational Safety
Issued 11 July 2001
Resolved
PROVE PROPER OPERATION OF BOTH HEADS & COMPLETE INSTALLATION OF TANKS_x001C_ PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Fire Fighting
Issued 11 July 2001
Resolved
PROVIDE 5/8 X 50FT FIREHOSE WITH NOZZLE
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Documentation
Issued 11 July 2001
Resolved
PROVIDE CURRENT DOCUMENTATION DECAL PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Lifesaving
Issued 11 July 2001
Resolved
PROVIDE EPIRB REGISTRATION PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Engineering
Issued 11 July 2001
Resolved
LABEL FO SHUT-OFF LOCATION & DIRECTION PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Lifesaving
Issued 11 July 2001
Resolved
CORRECTLY LABEL PFD STORAGE PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Unknown
Issued 11 July 2001
Resolved
PROVIDE EVIDENCE OF PRE-EMPLOYMENT & RANDOM DRUG TESTING ENROLLMENT FOR ALLEMPLOYEES PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Lifesaving
Issued 11 July 2001
Resolved
ATTACH PORT RAFT PAINTER TO WEAK LINK PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Engineering
Issued 11 July 2001
Resolved
PROVE PROPER OPERATION OF FO REMOTE SHUTDOWNS (3) PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Fire Fighting
Issued 4 June 2001
Resolved
PROVE PROPER OPERATION OF FIREPUMPS WITH DISCHARGE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 June 2001
Resolved 30 August 2001
Lifesaving
Issued 4 June 2001
Resolved
PROVIDE CURRENT NOAA REGISTRATION.
Condition: Unknown
Due 4 July 2001
Resolved 30 August 2001
Documentation
Issued 4 June 2001
Resolved
Unknown Component - Unknown Cause/Condition (46C.F.R.67.313)
Condition: Unknown
Due 4 July 2001
Resolved 30 August 2001
Lifesaving
Issued 4 June 2001
Resolved
CORRECT PFD STORAGE LABELS
Condition: Unknown
Due 4 July 2001
Resolved 30 August 2001
Fire Fighting
Issued 4 June 2001
Resolved
PROVIDE FIREHOSE AND NOZZLE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 4 June 2001
Resolved 30 August 2001
Lifesaving
Issued 4 June 2001
Resolved
PROVIDE PELICAN HOOK AND PROPERLY CONNECT STBD LR TO HYDRO RELEASE_x001C_ PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Electrical
Issued 4 June 2001
Resolved
BOND ER VALVES TO GROUND
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Accommodation/Occupational Safety
Issued 4 June 2001
Resolved
COMPLETE MSD INSTALLATION.
Condition: Unknown
Due 4 July 2001
Resolved 30 August 2001
Engineering
Issued 4 June 2001
Resolved
REPLACE STBD MDE OIL GAUGE/SENDER
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Lifesaving
Issued 4 June 2001
Resolved
CONDUCT CREW DRILLS WITH PERMANENT CREW
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Construction/Loadline
Issued 4 June 2001
Resolved
INSTALL HIGH LEVEL BILGE ALARM IN STORAGE HOLD.
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Navigation
Issued 4 June 2001
Resolved
REPAIR FORWARD MASTHEAD LIGHT PRIOR TO SAILING.
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Lifesaving
Issued 4 June 2001
Resolved
PROVIDE 1 TYPE 1 CHILD PFD PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 July 2001
Resolved 30 August 2001
Electrical
Issued 18 May 2000
Resolved
PROVIDE COVER FOR PORT BATTERY RACK.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Engineering
Issued 18 May 2000
Resolved
REPLACE PORT MAIN DIESEL ENGINE FUEL OIL RETURN LINE.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Fire Fighting
Issued 27 April 1999
Resolved
INSTALL FIRE PULL CABLE AND ENGINE SHUT-DOWNS TO EXISTING HALON SYSTEM. PROVIDE ANNUAL SERVICING CERTIFICATE FOR SAME.
Condition: Unknown
Due 27 May 1999
Resolved 25 May 1999
Accommodation/Occupational Safety
Issued 27 April 1999
Resolved
REINSTALL AFT HANDRAILS.
Condition: Unknown
Due 27 May 1999
Resolved 25 May 1999
Construction/Loadline
Issued 2 April 1997
Resolved
FOUND THAT PORT SEWAGE SEA VALVE STEM WAS BROKE UPON REMOVAL AND GATE HAD RUSTED IN PLACE IN THE CLOSED POSITION. ISSUED REQUIRMENT TO REPLACE VALVE PRIOR TO VESSEL RETURNED TO WATER.
Condition: Unknown
Due 3 April 1997
Resolved 2 April 1997
Navigation
Issued 21 October 1994
Resolved
REPLACE CROSS BAR BETWEEN STEERING POSTS.
Condition: Unknown
Due 22 October 1994
Resolved 24 October 1994
Documentation
Issued 15 July 1991
Resolved
PROVIDE A PROPER WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Documentation
Issued 15 July 1991
Resolved
READMEASURE VESSEL AS TO LENGTH. END TO END OVER THE DECK EXCLUDING SHEER IS PRESENTLY 63.5' BUT DOCUMENT LISTS LENGTH AS 67 FEET.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Lifesaving
Issued 15 July 1991
Resolved
MOUNT LIFERAFT PRIOR TO OPERATION OUTSIDE OF 20 MILES FROM A HARBOR OF SAFEREFUGE.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Lifesaving
Issued 15 July 1991
Resolved
MARK PROPER HOMEPORT ON STERN.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Engineering
Issued 15 July 1991
Resolved
PROVIDE GUARD FOR STARBOARD ENGINE PULLEY.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Engineering
Issued 15 July 1991
Resolved
MARK AFT EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Construction/Loadline
Issued 15 July 1991
Resolved
REPAIR SMALL GOUGE (3" X 1/2") TO CHINE 6' AFT OF BOW ON STARBOARD SIDE.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Documentation
Issued 15 July 1991
Resolved
PROVIDE DECKHAND QUALIFICATION PROGRAM FOR REVIEW.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Electrical
Issued 24 July 1990
Resolved
INSTALL RELAY TYPE EMERGENCY LIGHTING IN PASSENGER ACCOMADATION SPACES BELOW DECK.
Condition: Unknown
Due 24 July 1990
Resolved 24 July 1990
Accommodation/Occupational Safety
Issued 24 July 1990
Resolved
INSTALL SAFETY RAILS FOR COOKING POTS ON ELECTRIC STOVE IAW 46 CFR 183.10-45(3)
Condition: Unknown
Due 24 July 1990
Resolved 24 July 1990
Accommodation/Occupational Safety
Issued 24 July 1990
Resolved
PROVIDE INDICATING DEVICE ON SEWAGE HOLDING TANKS TO INDICATE 3/4 FULL.
Condition: Unknown
Due 24 July 1990
Resolved 24 July 1990