RAINISONG

RAINISONG is a 1987 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in April 2026, along with 83 deficiencies, 2 operational controls and 3 casualty investigations between 2017 and 2023.

Records from 2016 to 2026. Most recent: inspection, 9 April 2026.

Built
1987
Last inspected
9 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM3704
284719
Flag
UNITED STATES
Maury page id
psix-284719

Documentation record

Registered dimensions (L × B × D)63.7 ft × 18.4 ft × 7.5 ft
Registered tonnagegross 58 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM BOAT SHOP INC · HOQUIAM, WA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CALLISTO VOYAGER Passenger (Inspected) · MISLE 1275320 · 10 August 2023 · activity 7768320

Inspection history · 30

9 April 2026 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8343894
6 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8204117
15 January 2025 Internal Structural Exam · Deficiency Check · Administrative Inspection · Simplified Stability Test · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8064861
7 August 2024 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7976554
27 March 2024 Damage Survey · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7886108
5 September 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7786185
10 August 2023 Damage Survey · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7765312
10 August 2023 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7768320
9 August 2023 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7764499
7 November 2022 Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7590865
7 October 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7573728
1 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7549247
16 August 2022 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7535384
8 August 2022 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 7529571
5 January 2022 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7376281
7 September 2021 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7306918
24 May 2021 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7205990
16 May 2021 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7200636
10 May 2021 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7193746
5 November 2020 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7165118
16 June 2020 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6978759
14 August 2019 Deficiency Check · Drydock Exam · In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6784774
7 August 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6776164
9 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6404335
8 May 2018 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6420124
5 September 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6257197
12 June 2017 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6181696
21 April 2017 Deficiency Check · Examination of Repairs · Administrative Inspection · Annual Inspection · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6129945
16 July 2016 Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 5943013
11 May 2016 COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5866817

Deficiency record · 83

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. Vessel's installed bilge pumping arrangement using engine driven pump was incapable of taking suction from the engine room compartment due to a cracked hose. Additionally, another hose on the system on the pump is showing signs of external deterioration (cracking), requiring replacement. 46 CFR 182.25-1 (Old T)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2026
Resolved 27 April 2026
Resolution: Hoses in bilge system replaced and tested.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 April 2026 Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel's stability letter on board was out-of-date and had been superseded by a newer stability letter dated 21APR2025 referenced by the COI. 46 CFR 176.306
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 27 April 2026
Resolution: Current stability letter verified onboard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 9 April 2026 Resolved
The shutoff valve at the fuel tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Fuel oil tank shutoffs on the starboard forward and aft in the engine room were incapable of full closure.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 9 April 2026
Resolution: Master made changes to the clamping arrangement and fixed both fuel closure devices. Tested Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2024 Resolved
A flame shield is required for a marine type fuel strainer with a bowl of other than steel constrution. Starboard fuel strainer is missing flame shield. 46CFR182.455(b)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 15 January 2025
Resolution: installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2024 Resolved
Each small battery installation must be protected from falling objects. Starboard battery box is missing cover. 46CFR183.354(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 15 January 2025
Resolution: installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 August 2024 Resolved
Fastenings of each vessel must provide for safe operation with consideration given to the provision of a seaworthy hull. Starboard rudder post is leaking. 46CFR177.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 23 April 2025
Resolution: backing plate was cracked. Renewed backing plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2024 Resolved
Machinery must be maintained in such a manner as to afford adequate protection against machinery failure. Both main propulsion engine exhaust piping systems are leaking water. 46CFR182.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 23 April 2025
Resolution: installed new FRP exhaust tubes
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024 Resolved
Provide tech report attesting to integrity of stbd fuel line where battery cable grounded.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: fuel line repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2024 Resolved
Repair/renew any affected wiring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: wiring renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024 Resolved
Renew damaged fuel line on port MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: fuel hoses renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2024 Resolved
Ensure spent fire extinguishers are recharged/renewed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: rcvd report from technician
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure. Vessel reported loss of propulsion. Provide cause and repair for CG review and approval.
Action required: 10 - Deficiency Rectified
Resolved 10 August 2023
Resolution: Operator repaired cable mount bracket on port engine and demonstrated satisfactory operation of both engines to attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 January 2023 Resolved
All additional fire and safety requirements for overnight passengers have been implemented with the exception of the following categories: Watchkeeping, Training, Egress, Hazardous items. The vessel is restricted from carrying overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector. An op-control was opened.
Action required: 705 - Other - as specified
Resolved 9 August 2023
Resolution: The vessel is restricted from carrying more than six (6) overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 August 2022 Resolved
An adult life jacket must be provided for all persons. One (1) jacket was missing. Total passenger carriage allowance reduced by one (1) for a total of 47.
Action required: 705 - Other - as specified
Resolved 1 September 2022
Resolution: One adult PFD provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2022 Resolved
Fuel lines and filters provided with valves for removing water must be fitted with caps or plugs to prevent fuel leakage. The generator fuel strainer peacock valve is missing the cap or plug.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: plug provided
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 August 2022 Resolved
A high-water level indicator must be installed in spaces with through-hull fittings. The high level switch located in the lazarette space is in-operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: tested laz high water alarm, sat
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 August 2022 Resolved
All radiotelephones must contain integral GPS capabilities or must be connected to an electronic position-fixing device. Also, all radios must have the MMSI internally programmed. One radio has the incorrect MMSI and one radio needs to be connected to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: verified MMSI number in radio and gps in other radio
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 August 2022 Resolved
Marine Employers must ensure all crewman are enrolled in a Chemical Testing Program. The vessel does not have an updated Consortium letter with the company name and all enrolled crewman.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: letter onboard
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 August 2022 Resolved
Inspection and testing of all fire protection equipment must be serviced in accordance with NFPA. The 2022 annual third party servicing report was not provided for USCG review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 1 September 2022
Resolution: servicing report onboard
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 16 August 2022 Resolved
Operators must prevent the discharging of untreated sewage by any of the acceptable methods. The portside Type III device discharge valve was found open and all acceptable prevention methods were not met.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 16 August 2022
Resolved 16 August 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 August 2022 Resolved
All additional fire and safety requirements for overnight passengers have been implemented with the exception of the following categories: Watchkeeping, Training, Egress, Hazardous items. The vessel is restricted from carrying overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector. An op-control was opened.
Action required: 705 - Other - as specified
Resolved 7 November 2022
Resolution: The vessel is restricted from carrying overnight passengers until all remaining items have been inspected to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 May 2021 Resolved
Show proof that the vessel smoke detection units are in good working order throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2021
Resolution: verified satisfactory
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 May 2021 Resolved
Properly label all areas of means of escape in the accomodation & exit on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2021
Resolution: installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2021 Resolved
Provide guards or an effective means of preventing crew from rotating machinery in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 May 2021 Resolved
Secure wiring in engine room overhead with metal clamps spaced no more than 24" apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: installed
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 May 2021 Resolved
Provide proof that the vessel has valid FCC radio certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: renewed
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 10 May 2021 Resolved
Vessel needs to post the emergency instruction list for passengers to view.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: posted
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021 Resolved
Replace all expired medicines found in the required first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 2 June 2021
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 November 2020 Resolved
Approximate 5" crack, 3' above the waterline resulted from another vessel alliding with RAINISONG's port side, just aft of amidships. Make temporary repairs to the crack to prevent the intrusion of water to the satisfaction of Marine Inspector. In addition, test all high water alarms, bilge pumps, and conduct frequent rounds of internal spaces for water intrusion. Make permanent repairs at next drydock.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 9 November 2020
Resolution: Vessel made temporary repairs to the 5" crack using epoxy. Vessel in transit to Homer, AK for drydock. Notified MSD [name withheld] who will be attending.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 August 2020 Resolved
Light fixtures to have a guard or configured in a way to protect from a strike or impact. 01 light fixture was found to have no protection in the engine room.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep found the protective guard and re-installed around the light. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 August 2020 Resolved
All spaces that require a bilge pump shall be configured to have bilge pumps operate in auto and manual modes with a visual indicator showing operation in each mode.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Deckhand found loose bilge pump wiring connection for manual mode in engine room. Made on the spot repairs and tested bilge pump in both auto and manual mode. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 August 2020 Resolved
Vessel required to carry distress signals for the intended route and service. Expired flares were found onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep procured new flares to replace the ones found expired. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 August 2020 Resolved
Vessel to have a complete set of first aid equipment and medicine required for passenger operations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep procured new medicine to replace the expired medicines found onboard. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020 Resolved
Vessel to have its three fire buckets properly stenciled with lanyards attached to the handle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: Vessel rep stenciled "Fire Bucket" and attached lanyards to the handle that will reach the water line. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 September 2019 Resolved
Repair fiberglass hull damage on port aft corner
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 7 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2019 Resolved
All cable and wire must be installed with metal supports every 24 inches
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 7 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019 Resolved
Make permanent repairs to starboard railing and tighten down port railing bases
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 20 August 2020
Resolution: The starboard railing and port railing bases were properly secured to the base.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 13 September 2019 Resolved
Make permanent repair to port sewage tank
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 7 October 2019
Resolution: aluminum tank replaced with plastic one
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 August 2019 Resolved
Ensure fan in ER is secured while vessel is underway until properly connected to pre-engineered fire extinguishing system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 20 August 2020
Resolution: Owner elected to remove the fan. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2019 Resolved
Installed pre-engineered fixed fire extinguishing system is required a manual activation. Correct at next scheduled drydock (30SEP19).
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 7 October 2019
Resolution: New system installed and tested
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 August 2019 Resolved
Port strut, outboard backing plate is leaking water. Repair at next scheduled drydock (30SEP19).
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 7 October 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 August 2019 Resolved
Port rudder post leaks excessively. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 7 October 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 August 2019 Resolved
Fixed system was in over ride on bridge. System in ER was disconnected. Required to have system operational and serviced by technician prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2019
Resolution: System connected by fire servicing tech and tested satisfactory.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 August 2019 Resolved
Vessel has two Type III tanks with individual discharge valves. Both valves were open and were not able to be closed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2019
Resolution: Operation test sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 7 August 2019 Resolved
No proof of enrollment in USCG approved random drug testing program for the crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2019
Resolution: Reviewed enrollment form
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 August 2019 Resolved
Water found coming through FRP where stbd shaft log meets hull. Make approved temp repairs until vessel can be hulled out where permanent repairs can be made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2020
Resolution: Verified FRP repairs were conducted on the stbd shaft log where it meets the hull. No active leaking was identified. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 August 2019 Resolved
Original COD not on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 August 2019 Resolved
Waste Management Plan needs updated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 20 August 2020
Resolution: Vessel rep provided an adequate waste management plan. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2019 Resolved
Portable fire extinguisher required on the bridge must be mounted in approved bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 8 August 2019
Resolution: Properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 August 2019 Resolved
Ensure smoke detectors in overnight accommodation spaces are operational. Correct prior to using overnight accommodation spaces.
Action required: 705 - Other - as specified
Resolved 7 October 2019
Resolution: Kiddie Bluetooth connected smoke detectors installed throughout the vessel
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 August 2019 Resolved
Ensure E-lighting in overnight accommodation spaces are operation prior to using overnight accommodation space.
Action required: 705 - Other - as specified
Resolved 7 October 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 August 2019 Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 August 2019 Resolved
No visual alarm for high water alarm in the following spaces: tank room/dry stores, berthing, laz.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 August 2019 Resolved
Label high level alarm spaces at operating spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 August 2019 Resolved
Provide donning placards for PFDs that are onboard and provide launching insttructions for IBA.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 7 October 2019
Communications › Radio Communications › EPIRB
Issued 9 May 2018 Resolved
hydrostatic release expired
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2018
Resolved 23 May 2018
Resolution: signed and dated as cleared by [name withheld], CWO4
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2018 Resolved
water in lazerette, need to repair/tighten packing gland, remove water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2018
Resolved 10 May 2018
Resolution: night before demonstrated to CG water was removed in space, tightened gland packing bolt, next day CG checked space for water
Engineering › Fuel Oil Service System › Piping
Issued 21 June 2017 Resolved
Permanently repair fuel piping at aft-port bulkhead of engine room
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 8 May 2018
Resolution: Verified proper repair in fuel piping.
Engineering › Fuel Oil Service System › Valve
Issued 21 June 2017 Resolved
Properly secure and label operation sequence of remote fuel shut off cable for MDEs and Generator
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 21 July 2017
Resolution: corrected satisfactorily
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 June 2017 Resolved
Secure thru-hull valve starboard side aft in engine room that is no longer in use
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 July 2017
Resolution: secured satisfactorily
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 15 June 2017 Resolved
Provide CG-2692 for flooding caused by washdown pump
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 June 2017
Resolution: CG-2692 submitted
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 15 June 2017 Resolved
Prove proper operation of main engines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Resolution: Engines are now starting
Stability › Watertight Integrity › General
Issued 15 June 2017 Resolved
Pump all water out of bilges
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 21 July 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 June 2017 Resolved
Prove proper operation of all bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2017
Resolution: all visual and audible alarms are now operational
Engineering › Bilge Water Management System › Pump
Issued 15 June 2017 Resolved
Prove proper operation of all bilge suction points for fixed bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Resolution: tested all suction points, all sat
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 15 June 2017 Resolved
Tighten packing on shafts to prevent leaking in engine room
Action required: 705 - Other - as specified
Resolved 21 July 2017
Construction/Loadline › Structures › Machinery Space Opening
Issued 15 June 2017 Resolved
Identify and repair holes in bulkheads (between engine room and tank room, also between tank room and space forward)
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 8 May 2018
Resolution: Verified holes in bulkhead have been sealed up.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 26 April 2017 Resolved
Provide working smoke detectors in accommodation space.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 June 2017
Resolution: Smoke detectors now operational
Engineering › Bilge Water Management System › Not Installed
Issued 26 April 2017 Resolved
Secure Rule bilge pumps in engine room and lazarette
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 21 July 2017
Resolution: bilge pumps are now secure
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 April 2017 Resolved
Provide fire servicing certificate showing operational test of fire boy system
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 2 June 2017
Resolution: servicing report received
Engineering › Fuel Oil Service System › Valve
Issued 26 April 2017 Resolved
Replace starboard generator remote fuel valve handle
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 July 2017
Resolution: handle replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2017 Resolved
Install metal supports every 24" on wiring in engine room
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 9 May 2018
Resolution: Received email picture verifying proper metal supports.
Documentation › Certificates/Documents › FCC SSL
Issued 11 May 2016 Resolved
Provide copy of FCC Ship station license
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 25 May 2016
Resolution: Provided copy of FCC license
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 May 2016 Resolved
provide fcc radiotelephony cert
Due 11 May 2016
Resolved 25 May 2016
Resolution: Provided copy of certificate
Documentation › Logs/Records › Drug Test Records
Issued 11 May 2016 Resolved
Provide Alcohol test strips and DAPI enrollment.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Provide strips and DAPI paperwork
Navigation › Piloting/Steering › Marine Charts
Issued 11 May 2016 Resolved
Provide updated Charts, light list and coast pilot
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 8 June 2016
Resolution: Charts and Coast Pilot updated on 25May16. Light List completed 8JUN16.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 May 2016 Resolved
Replace fire brackets on aft deck (2)
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Brackets were replaced
Electrical › Electric Generation Source (service) › Generator Cable
Issued 11 May 2016 Resolved
Connect grounding wired in engine room
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Grounding wires were connected
Documentation › Markings/Placards › Garbage Placard
Issued 11 May 2016 Resolved
Provide garbage placard
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 12 May 2016
Resolution: provided garbage placard
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 May 2016 Resolved
Bilge Alarm must be labeled correctly at operating station for bunkroom.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Bilge alarms labelled correctly
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2016 Resolved
Remove or properly cap dead end wires under helm
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 12 May 2016
Resolution: Capped dead end wires
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 May 2016 Resolved
STBD Aft and FWD in engine room emergency fuel shut offs repaired (2)
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 12 May 2016
Resolution: Repaired both shut off valves
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 May 2016 Resolved
Engine room fire damper needs replaced
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 12 May 2016
Resolution: Replaced damper

Casualty record · 3

12 June 2017Routine · role: Involved in a Marine Casualty · activity 6181696
16 May 2021Routine · role: Involved in a Marine Casualty · activity 7200636
10 August 2023Routine · role: Involved in a Marine Casualty · activity 7768320
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.