CAROLINE

CAROLINE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1987, most recently in June 2026, along with 64 deficiencies and 2 casualty investigations between 2006 and 2023.

Records from 1987 to 2026. Most recent: inspection, 17 June 2026.

Built
1987
Last inspected
17 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD6402
285632
Flag
UNITED STATES
367172460
Maury page id
psix-285632

Inspections, by type

…with no type recorded9
Years with a record 35 calendar years (1987–2026)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)66.8 ft × 21.4 ft × 8.8 ft
Registered tonnagegross 89 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC. · WESTPORT WA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLA-LONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ5042MMSI 367172460 · active · compulsorily equipped · granted 20 April 2017, expires 20 April 2027
WDD6402MMSI 367172460 · terminated · compulsorily equipped · granted 13 March 2007, cancelled 12 April 2017
WBG8024MMSI not assigned · expired · compulsorily equipped · granted 16 April 1997, cancelled 16 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAJESTIC Passenger (Inspected) · MISLE 662579 · 2 January 2006 · activity 2559723

Inspection history · 88

17 June 2026 Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8407099
19 May 2026 Annual Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8325187
14 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8124240
25 March 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8082131
6 December 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040495
1 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7866119
8 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675399
4 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624706
21 March 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7742565
14 March 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624707
21 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7431801
8 July 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249274
24 March 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162048
16 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7017598
15 July 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706770
26 March 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6645383
9 July 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6528122
25 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6415366
19 October 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6290812
21 April 2017 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6122412
15 March 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129983
7 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5873989
13 May 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4817785
17 March 2009 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3432954
13 January 2009 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3393420
13 May 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158782
19 March 2008 Deadweight Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3164971
27 September 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3067731
1 June 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2948890
9 May 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2926177
25 April 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2914593
27 March 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2895388
13 March 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2870906
6 June 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2638034
24 February 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2591425
3 January 2006 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2559712
2 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2559723
5 December 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2546132
13 June 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2385312
24 May 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2355071
6 January 2005 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270038
16 December 2004 Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2260870
15 July 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2133925
24 June 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2074487
29 January 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1997152
5 December 2003 Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1959537
17 November 2003 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1949562
27 May 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1793744
17 April 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1775019
4 February 2003 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1735898
2 May 2002 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1611851
14 March 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1493129
5 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1073777
11 April 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1405148
22 February 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395626
15 March 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395381
10 June 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809088
27 May 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805409
19 March 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365110
8 April 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788429
2 December 1997 Deadweight Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1115465
7 November 1997 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788351
4 June 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1383576
19 March 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103177
11 April 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1090484
19 March 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1374535
20 February 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078748
21 March 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151333
24 March 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1169142
9 February 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163102
16 November 1993 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143480
14 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 154148
14 September 1993 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144367
23 March 1993 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1149020
27 March 1992 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962145
6 February 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 953403
19 April 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228461
28 March 1991 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225515
11 April 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 913704
9 April 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1215185
2 May 1989 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193811
9 August 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1038722
4 May 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044427
2 November 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1020908
1 September 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1002411
1 September 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1310003
4 June 1987 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1021184
4 June 1987 Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031813

Deficiency record · 64

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed severe jacket water leak from SMDE, thus overheating and a failed cooling water pump. Vessel to prove proper operation of the SMDE. 46CFR182.05-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Vessel made proper repairs to the STBD MDE by renewal of the raw water pump impellor. MI examined vessel while underway with a satisfactory operational test of main propulsion engines under full load.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 19 May 2026 Resolved
All vessels shall be fitted w/such ground tackle and hawsers as deemed necessary. by OCMI. Vessel anchor chain unserviceable/broken and in need of renewal/replacement. 46CFR184.10-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Vessel properly renewed anchor chain.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2026 Resolved
The MI shall require that all observed unsafe and hazardous situations be corrected. Vessel has at the following locations dead end wires: Bridge console, LF box, Outlet in galley, Aft flag pole to be removed. 46CFR176.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel removed and/or properly capped exposed wires in all identified areas to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2026 Resolved
The containers in which lifejackets are stowed shall be marked w/number. Life jacket number sign on upper deck broken, donning placard unreadable. 46CFR180.25-15(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel installed new placards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2026 Resolved
Bilge pipe piercing the collision bulkhead shall be fitted with screw down valve. Vessel has ball valve installed. 46CFR182.25-5(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel installed screw down valve & completed a satisfactory operational test of bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 July 2025 Resolved
Cable and wiring requirements. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Electrical outlet near vending booth missing cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Operator provided photo of electric outlet enclosure with fitted cover.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 14 July 2025 Resolved
Suitable hand grabs must be installed where necessary in passageways, at deck house sides, and at ladders and hatches. Handrail leading up stairway from passenger cabin to wheelhouse is loose.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Operator provided statement hand rail tightened and fixed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. 01 portable fire extinguisher was missed by servicing company in 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Received report showing completion of annual firefighting servicing.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Inspector found the vessel did not have onboard updated charts. The last update of the electronic chart display could not be verified.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 2 June 2022
Resolution: Operator provided updated chart information.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 April 2022 Resolved
A self-propelled vessel of 65 feet or more in length, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. Inspector found that the vessels AIS was not broadcasting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 2 June 2022
Resolution: Vessels AIS made operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 August 2020 Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A. Vessel removed the wet chemical fire protection from system because they no longer use the galley equipment. Provide proof of a permanent disconnection of the galley equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2020
Resolved 10 August 2020
Resolution: Vessel blanked off both breakers for the galley oven and range, and posted a note on both galley devices to notify coast guard before re-connecting.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 August 2020 Resolved
In the design of a control, interlock, or indicator circuit, the disconnect device and its connections, including each terminal block for terminating the vessel's wiring, must not have any electrically unshielded or uninsulated surfaces. Circuit breaker distribution panel contained 02 breakers covered in duct tape. Remove all duct tape from panel. 46 CFR 183.330(i)
Action required: 10 - Deficiency Rectified
Resolved 3 August 2020
Resolution: Vessel removed all duct tape from the electrical panel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 July 2019 Resolved
a visual and audible alarm must be must be provided at the operating station to indicate a high water level in a space with a through hull fitting below the deepest load waterline, such as a lazarette. Lazarette high level alarm not funtional. prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Deficiency corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2019 Resolved
each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. light on stbd side life float not functional. Prove functionality / proper installation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Deficiency correct on the spot
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 25 June 2018 Resolved
Prove halon 1301 bottle is properly charged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2018
Resolved 27 June 2018
Engineering › Pressure Vessel › Relief Valve
Issued 25 June 2018 Resolved
Prove pressure vessel relief valve is set below max allowable working pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2018
Resolved 27 June 2018
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 25 June 2018 Resolved
Properly secure painter to hydrostatic release unit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 June 2018
Resolved 25 June 2018
Lifesaving › Inflatable Liferafts › Weak Link
Issued 13 May 2014 Resolved
Vessel's two (02) inflatable liferafts were incorrectly installed to deck after recent servicing on May 8th, 2014. Each painter line from both liferafts was not attached to plastic red weak-link, making liferafts incapable of inflation.
Condition: Improper Installation
Due 13 May 2014
Resolved 13 May 2014
Resolution: Gathered both masters and deckhand and thoroughly instructed proper procedures for installing liferafts. Issue was then fixed on the spot.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 13 May 2014 Resolved
Vessel lacked an up-to-date employee list for drug & alcohol testing program. Employee list of 2013 failed to include a current crewmember.
Condition: Invalid
Due 13 May 2014
Resolved 13 May 2014
Resolution: Vessel''''s facility was thereafter able to provide a current 2014 list of employees enrolled in the drug & alcohol testing program. Item fixed on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 May 2008 Resolved
Replace or repair 55 adult Type I personal flotation devices. Passenger count reduced to 94 total adult passengers IAW 46CFR180.71(a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: 55 adult Type I personal flotation devices repaired; all satisfactory and in serviceable condition.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 May 2008 Resolved
Provide cover for emergency light fixture in space above main deck back bar IAW 46CFR183.410(a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: Cover for emergency light fixture installed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 May 2008 Resolved
Demonstrate illumination of magnetic compass at operating station IAW 46CFR184.402(c).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: Magnetic compass illumination confirmed.
Stability › Incline Test › General
Issued 9 May 2007 Resolved
Provide new stability letter approved by the Marine Safety Center for vessel with canvas enclosure. Vessel is restricted to protected waters with winds less than 25 knots.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 31 May 2007
Resolution: Owner/Operator removed the canvas enclosure. Vessel is fit for its intended route and service specified on its COI.
Stability › Watertight Integrity › General
Issued 13 March 2007 Resolved
Provide positive action valve IWO secondary bilge pump discharge fitting located in the lazzerett, starboard side as required by 46 CFR 179.350.
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 25 April 2007
Resolution: Valve installled.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 March 2007 Resolved
Provide permanent installation for the shore power cable connection as required by 46 CFR 183.390.
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 25 April 2007
Resolution: Shore Power cable permanently installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 March 2007 Resolved
Provide alcohol testing devices as required by 46 CFR 16.240.
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 25 April 2007
Resolution: Testing devices on baord.
Construction/Loadline › Structures › Superstructure
Issued 3 January 2006 Resolved
Provide repairs to rear, starboard corner of upper deck. Passengers may not be carried on upper deck until repairs are completed.
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 24 February 2006
Resolution: Repairs completed.
Stability › Incline Test › General
Issued 5 December 2005 Resolved
Provide new stability letter approved by MSC for vessel with canvas enclosure installed.
Action required: 705 - Other - as specified
Due 11 January 2006
Resolved 3 January 2006
Resolution: Removed canvas enclosure.
Construction/Loadline › Hull › Side Shell
Issued 13 June 2005 Resolved
Two port quarter stainless steel brackets that used to hold a gang way were missing two 1/2" bolts. From inside the lazerte, daylight could be observed and evidence of water seepage was found. Owner/Operator installed two bolts and resolved the problem.
Condition: Improper Installation
Due 13 June 2005
Resolved 13 June 2005
Resolution: Repaired before the end of the annual SV-T exam
Lifesaving › Hand Flares › Storage
Issued 13 June 2005 Resolved
Orange box for flares was missing.
Condition: Placed in Improper Service
Due 13 June 2005
Resolved 13 June 2005
Resolution: Owner/operator furnished replacement orange box and properly labeled container.
Engineering › Bilge Water Management System › Not Operational
Issued 13 June 2005 Resolved
Mid section bilge float alarm in unused stateroom was not operational.
Condition: Improper/Lack of Maintenance
Due 13 June 2005
Resolved 13 June 2005
Resolution: Owner/operator replaced broken/frozen bilge float before the end of the SV-T annual inspection.
Stability › Severe Wind/Roll › General
Issued 16 December 2004 Resolved
Provide another stability letter approved by Marine Safety Center for canvas enclosure. Vessel is restricted to protected waters with winds less than 25 knots.
Action required: 705 - Other - as specified
Due 5 January 2005
Resolved 30 December 2004
Resolution: Canvas enclosure was removed. No additional stability letter is required.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 June 2004 Resolved
Label emergency escape hatch leading from restroom area.
Action required: 705 - Other - as specified
Due 13 July 2004
Resolved 15 July 2004
Resolution: Placed "emergency escape" label on hatch.
Documentation › Markings/Placards › Certificate of Number (state)
Issued 24 June 2004 Resolved
Match name of vessel w/COI and COD, additionally match all lifesaving equipment w/appropriate vessel name.
Action required: 705 - Other - as specified
Due 13 July 2004
Resolved 15 July 2004
Resolution: Properly labeled all lifejackets, liferings, BA''s, lifefloats, and vsls hull.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 24 June 2004 Resolved
Replace/repair port propellar shaft packing gland.
Due 29 June 2004
Resolved 29 June 2004
Resolution: Corrected on the spot.
Stability
Issued 5 December 2003 Resolved
Provide another stability letter approved by Marine Safety Center for canvas enclosure. Vessel is restricted to protected waters with winds less than 25 knots.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 12 January 2004
Resolution: Canvas enclosure and structure was removed. Vessel was put back to previous stability condition and Protected Waters restriction lifted. Route remains as per current COI. No new stability letter required at this time.
Navigation › Piloting/Steering
Issued 17 April 2003 Resolved
Renew Light List per 46 CFR 184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 27 May 2003
Resolution: New list on board.
Navigation › Piloting/Steering
Issued 17 April 2003 Resolved
Update navigation charts in accordance with Notice to Mariners. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 27 May 2003
Resolution: Updated to 30April03.
Stability › Watertight Integrity
Issued 17 April 2003 Resolved
Seal bolt holes located port and starboard bulkhead in lazerette. LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 21 November 2003
Resolution: Bolt holes are sealed.
Personnel › Certificates/Documents/Licenses
Issued 17 April 2003 Resolved
Prove First Aid/CPR cards for 50% of crew per NVIC 1-91. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 27 May 2003
Resolution: Witnessed cards for whole crew.
Documentation › Logs/Records
Issued 17 April 2003 Resolved
Provide updated Drug and Alcohol Program and make available recent Drug and Alcohol test results for crew, per 46 CFR Part 16. LEGACY COMPONENT DESC: Drug Test Records
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 27 May 2003
Resolution: all sat.
Documentation › Certificates/Documents
Issued 17 April 2003 Resolved
Provide liferaft servicing certificates per 41 CFR 160.151. LEGACY COMPONENT DESC: Liferaft Servicing Certificates
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 27 May 2003
Resolution: All sat.
Electrical
Issued 4 February 2003 Resolved
Provide proper connection for forward compartment bilge pump wiring.
Due 4 February 2003
Resolved 4 February 2003
Resolution: Forward compartment bilge pump wiring properly connected.
Electrical
Issued 4 February 2003 Resolved
Provide proper connection for overhead wiring in way of forward compartment store room.
Due 4 February 2003
Resolved 4 February 2003
Resolution: Wiring in forward compartment store room properly connected.
Documentation › Markings/Placards
Issued 4 February 2003 Resolved
Properly label emergency escape hatch in way of dining room.
Due 4 February 2003
Resolved 4 February 2003
Resolution: Emergency escape hatch properly labeled
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 March 2002 Resolved
Renew retroreflective material on four life preservers.
Condition: Unknown
Due 14 March 2002
Resolved 14 March 2002
Resolution: Corrected prior to end on inspection.
Lifesaving › Lifebuoys › Stowage
Issued 14 March 2002 Resolved
Properly rig ring buoy waterlight.
Condition: Improper Installation
Due 14 March 2002
Resolved 14 March 2002
Resolution: Waterlight was made up at the bitter end of the 60 foot line. Master attached the watelight to a 6 foot line and installed a brass clip prior to end of inspection.
Lifesaving › Buoyant Apparatus
Issued 14 March 2002 Resolved
Provide two boat oars for 6-man life float. LEGACY COMPONENT DESC: oars
Condition: Unknown
Due 14 March 2002
Resolved 14 March 2002
Resolution: Corrected prior to end of inspection.
Electrical
Issued 19 March 1999 Resolved
Repair exhaust fan motor for galley range hood.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Fire Fighting
Issued 19 March 1999 Resolved
Provide means of automatic shut down of vessels main diesel engines and diesel generators upon activation of fixed engineroom halon system.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 2 December 1997 Resolved
Complete and submit to the Coast Guard the deadweight survey calculations for review. The total passenger count is reduced by (2) from 138 to 136 (the upper deck may accomodate no more than 46 passengers)
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 19 March 1997 Resolved
PURCHASE AND INSTALL 406 MHZ EPIRB.
Condition: Unknown
Due 19 March 1997
Resolved 19 March 1997
Documentation
Issued 19 March 1996 Resolved
PROVIDE COPY OF RECENT VOYAGE PLAN (185.503) AND PASSENGER COUNT (185.504) OR PROOF OF LOG STARTED IF ABOVE DOESN'T YET APPLY (NO COASTWISE/OVERNIGHT VOYAGES, NO PASSENGERS CARRIED).
Condition: Unknown
Due 19 April 1996
Resolved 1 April 1996
Lifesaving
Issued 19 March 1996 Resolved
PROVIDE PROOF OF INSTALLATION ON VESSEL OF DONNING INSTRUCTIONS FOR EACH TYPE OF LIFEJACKET CARRIED IAW INTERIM FINAL RULE 185,506(b)(2)(iii).
Condition: Unknown
Due 19 April 1996
Resolved 26 May 1996
Fire Fighting
Issued 23 March 1993 Resolved
PROVIDE SERVICING CERTIFICATE FOR PORTABLE FIRE EXTINGUISHERS. (PORTABLES ARE DUE FOR THEIR SIX YEAR DRY CHEM RECHARGE)
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Engineering
Issued 23 March 1993 Resolved
PROVE PROPER OPERATION OF TWO PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Electrical
Issued 27 March 1992 Resolved
PROVIDE PLACARDS FOR EMERGENCY ESCAPE HATCHES "KEEP CLEAR - EMERGENCY_x001C_ EXIT."
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Accommodation/Occupational Safety
Issued 27 March 1992 Resolved
PROVIDE SCREWS AND PROPERLY SECURE ALL RAILING STANCHIONS ON THE BOW.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 27 March 1992 Resolved
PROVIDE LATCH FOR ACCESS TO BULWARK PORT SIDE FWD.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Unknown
Issued 27 March 1992 Resolved
PROVIDE PLACARD "NO PASSENGERS" OR SIMILAR VERBAGE IN WAY OF GALLEY.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Deck/Cargo
Issued 27 March 1992 Resolved
PROVE OPERATION OF BOW CAPSTAN.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Electrical
Issued 27 March 1992 Resolved
PROVIDE/PROPERLY INSTALL AND MARK EMERGENCY LIGHTING FOR MASTER'S STATEROOM AND HEADS AS PER 46 CR 184.30.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Engineering
Issued 9 April 1990 Resolved
HAVE AIR RECIEVER HYDROED AND PROVIDE COPY OF REPORT TO THE OCMI.
Condition: Unknown
Due 14 March 2002
Resolved 14 March 2002
Documentation
Issued 9 August 1988 Resolved
PROVIDE VALID VESSEL DOCUMENT.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988

Casualty record · 2

2 January 2006Routine · role: Involved in a Marine Casualty · activity 2559723
21 March 2023Routine · role: Involved in a Marine Casualty · activity 7742565
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.