Records from 2006 to 2026. Most recent: inspection, 17 June 2026.
Documentation record
Registered dimensions (L × B × D)66.8 ft × 21.4 ft × 8.8 ft
Registered tonnagegross 89 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC. · WESTPORT WA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLA-LONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
17 June 2026
Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8407099
19 May 2026
Annual Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8325187
14 July 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8124240
25 March 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8082131
6 December 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040495
1 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7866119
8 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675399
4 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624706
21 March 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7742565
14 March 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624707
21 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7431801
8 July 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249274
24 March 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162048
16 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7017598
15 July 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706770
26 March 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6645383
9 July 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6528122
25 June 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6415366
19 October 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6290812
21 April 2017
COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6122412
15 March 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129983
7 June 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5873989
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed severe jacket water leak from SMDE, thus overheating and a failed cooling water pump. Vessel to prove proper operation of the SMDE.
46CFR182.05-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Vessel made proper repairs to the STBD MDE by renewal of the raw water pump impellor. MI examined vessel while underway with a satisfactory operational test of main propulsion engines under full load.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 19 May 2026
Resolved
All vessels shall be fitted w/such ground tackle and hawsers as deemed necessary. by OCMI. Vessel anchor chain unserviceable/broken and in need of renewal/replacement.
46CFR184.10-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Vessel properly renewed anchor chain.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2026
Resolved
The MI shall require that all observed unsafe and hazardous situations be corrected. Vessel has at the following locations dead end wires: Bridge console, LF box, Outlet in galley, Aft flag pole to be removed.
46CFR176.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel removed and/or properly capped exposed wires in all identified areas to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2026
Resolved
The containers in which lifejackets are stowed shall be marked w/number. Life jacket number sign on upper deck broken, donning placard unreadable.
46CFR180.25-15(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel installed new placards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2026
Resolved
Bilge pipe piercing the collision bulkhead shall be fitted with screw down valve. Vessel has ball valve installed.
46CFR182.25-5(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel installed screw down valve & completed a satisfactory operational test of bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 July 2025
Resolved
Cable and wiring requirements. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Electrical outlet near vending booth missing cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Operator provided photo of electric outlet enclosure with fitted cover.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 14 July 2025
Resolved
Suitable hand grabs must be installed where necessary in passageways, at deck house sides, and at ladders and hatches. Handrail leading up stairway from passenger cabin to wheelhouse is loose.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Operator provided statement hand rail tightened and fixed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. 01 portable fire extinguisher was missed by servicing company in 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Received report showing completion of annual firefighting servicing.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Inspector found the vessel did not have onboard updated charts. The last update of the electronic chart display could not be verified.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 2 June 2022
Resolution: Operator provided updated chart information.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 April 2022
Resolved
A self-propelled vessel of 65 feet or more in length, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. Inspector found that the vessels AIS was not broadcasting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 2 June 2022
Resolution: Vessels AIS made operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 August 2020
Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A. Vessel removed the wet chemical fire protection from system because they no longer use the galley equipment. Provide proof of a permanent disconnection of the galley equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2020
Resolved 10 August 2020
Resolution: Vessel blanked off both breakers for the galley oven and range, and posted a note on both galley devices to notify coast guard before re-connecting.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 August 2020
Resolved
In the design of a control, interlock, or indicator circuit, the disconnect device and its connections, including each terminal block for terminating the vessel's wiring, must not have any electrically unshielded or uninsulated surfaces. Circuit breaker distribution panel contained 02 breakers covered in duct tape. Remove all duct tape from panel.
46 CFR 183.330(i)
Action required: 10 - Deficiency Rectified
Resolved 3 August 2020
Resolution: Vessel removed all duct tape from the electrical panel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 July 2019
Resolved
a visual and audible alarm must be must be provided at the operating station to indicate a high water level in a space with a through hull fitting below the deepest load waterline, such as a lazarette. Lazarette high level alarm not funtional. prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Deficiency corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2019
Resolved
each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. light on stbd side life float not functional. Prove functionality / proper installation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Deficiency correct on the spot
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 25 June 2018
Resolved
Prove halon 1301 bottle is properly charged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2018
Resolved 27 June 2018
Engineering › Pressure Vessel › Relief Valve
Issued 25 June 2018
Resolved
Prove pressure vessel relief valve is set below max allowable working pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2018
Resolved 27 June 2018
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 25 June 2018
Resolved
Properly secure painter to hydrostatic release unit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 June 2018
Resolved 25 June 2018