CAROLINE

CAROLINE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in June 2026, along with 17 deficiencies and 2 casualty investigations between 2006 and 2023.

Records from 2006 to 2026. Most recent: inspection, 17 June 2026.

Built
1987
Last inspected
17 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6402
285632
Flag
UNITED STATES
Maury page id
psix-285632

Documentation record

Registered dimensions (L × B × D)66.8 ft × 21.4 ft × 8.8 ft
Registered tonnagegross 89 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC. · WESTPORT WA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLA-LONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

17 June 2026 Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8407099
19 May 2026 Annual Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8325187
14 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8124240
25 March 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8082131
6 December 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040495
1 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7866119
8 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675399
4 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624706
21 March 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7742565
14 March 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624707
21 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7431801
8 July 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249274
24 March 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162048
16 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7017598
15 July 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706770
26 March 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6645383
9 July 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6528122
25 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6415366
19 October 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6290812
21 April 2017 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6122412
15 March 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129983
7 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5873989

Deficiency record · 17

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed severe jacket water leak from SMDE, thus overheating and a failed cooling water pump. Vessel to prove proper operation of the SMDE. 46CFR182.05-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Vessel made proper repairs to the STBD MDE by renewal of the raw water pump impellor. MI examined vessel while underway with a satisfactory operational test of main propulsion engines under full load.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 19 May 2026 Resolved
All vessels shall be fitted w/such ground tackle and hawsers as deemed necessary. by OCMI. Vessel anchor chain unserviceable/broken and in need of renewal/replacement. 46CFR184.10-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Vessel properly renewed anchor chain.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2026 Resolved
The MI shall require that all observed unsafe and hazardous situations be corrected. Vessel has at the following locations dead end wires: Bridge console, LF box, Outlet in galley, Aft flag pole to be removed. 46CFR176.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel removed and/or properly capped exposed wires in all identified areas to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2026 Resolved
The containers in which lifejackets are stowed shall be marked w/number. Life jacket number sign on upper deck broken, donning placard unreadable. 46CFR180.25-15(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel installed new placards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2026 Resolved
Bilge pipe piercing the collision bulkhead shall be fitted with screw down valve. Vessel has ball valve installed. 46CFR182.25-5(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
Resolution: Vessel installed screw down valve & completed a satisfactory operational test of bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 July 2025 Resolved
Cable and wiring requirements. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Electrical outlet near vending booth missing cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Operator provided photo of electric outlet enclosure with fitted cover.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 14 July 2025 Resolved
Suitable hand grabs must be installed where necessary in passageways, at deck house sides, and at ladders and hatches. Handrail leading up stairway from passenger cabin to wheelhouse is loose.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Operator provided statement hand rail tightened and fixed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. 01 portable fire extinguisher was missed by servicing company in 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Received report showing completion of annual firefighting servicing.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Inspector found the vessel did not have onboard updated charts. The last update of the electronic chart display could not be verified.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 2 June 2022
Resolution: Operator provided updated chart information.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 April 2022 Resolved
A self-propelled vessel of 65 feet or more in length, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. Inspector found that the vessels AIS was not broadcasting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 2 June 2022
Resolution: Vessels AIS made operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 August 2020 Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A. Vessel removed the wet chemical fire protection from system because they no longer use the galley equipment. Provide proof of a permanent disconnection of the galley equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2020
Resolved 10 August 2020
Resolution: Vessel blanked off both breakers for the galley oven and range, and posted a note on both galley devices to notify coast guard before re-connecting.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 August 2020 Resolved
In the design of a control, interlock, or indicator circuit, the disconnect device and its connections, including each terminal block for terminating the vessel's wiring, must not have any electrically unshielded or uninsulated surfaces. Circuit breaker distribution panel contained 02 breakers covered in duct tape. Remove all duct tape from panel. 46 CFR 183.330(i)
Action required: 10 - Deficiency Rectified
Resolved 3 August 2020
Resolution: Vessel removed all duct tape from the electrical panel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 July 2019 Resolved
a visual and audible alarm must be must be provided at the operating station to indicate a high water level in a space with a through hull fitting below the deepest load waterline, such as a lazarette. Lazarette high level alarm not funtional. prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Deficiency corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2019 Resolved
each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. light on stbd side life float not functional. Prove functionality / proper installation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2019
Resolution: Deficiency correct on the spot
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 25 June 2018 Resolved
Prove halon 1301 bottle is properly charged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2018
Resolved 27 June 2018
Engineering › Pressure Vessel › Relief Valve
Issued 25 June 2018 Resolved
Prove pressure vessel relief valve is set below max allowable working pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2018
Resolved 27 June 2018
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 25 June 2018 Resolved
Properly secure painter to hydrostatic release unit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 June 2018
Resolved 25 June 2018

Casualty record · 2

2 January 2006Routine · role: Involved in a Marine Casualty · activity 2559723
21 March 2023Routine · role: Involved in a Marine Casualty · activity 7742565
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.