MAJESTIC

MAJESTIC is a 2003 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2016, most recently in May 2026, along with 109 deficiencies and 5 casualty investigations between 2006 and 2018.

Records from 2006 to 2026. Most recent: inspection, 13 May 2026.

Built
2003
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8986016
WDI7186
662579
Flag
UNITED STATES
Maury page id
psix-662579

Documentation record

Registered dimensions (L × B × D)125.1 ft × 30.0 ft × 10.0 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)125.1 ft × 30.0 ft × 10.0 ft
ITC tonnagegross 721 / net 233
BuilderSKIPPERLINER INDUSTRIES INC · LA CROSSE, WI, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it721 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
233 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HOKU KEA Commercial Fishing Vessel · MISLE 1227980 · 11 February 2017 · activity 6101471

Inspection history · 31

13 May 2026 Vessel Attendance · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8350265
8 January 2026 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8296528
25 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8167666
7 April 2025 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8089628
7 January 2025 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8059806
27 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7943189
26 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7711035
7 April 2023 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7631706
11 July 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7507599
4 January 2022 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7524308
17 May 2021 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7191117
6 April 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170124
19 August 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7021412
16 February 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6909778
19 December 2019 Administrative Inspection · DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6876976
10 July 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6703863
3 May 2019 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6678327
17 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6515347
1 August 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6498072
13 July 2018 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6473677
2 March 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6366521
17 August 2017 Damage Survey · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6243883
16 August 2017 Deficiency Check · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6243080
14 July 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6227882
8 June 2017 Administrative Inspection · Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6190250
5 April 2017 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6118531
11 February 2017 Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6086678
11 February 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6101471
2 November 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6064751
2 May 2016 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867382
15 January 2016 Plan Review (Other than "T") · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5798157

Deficiency record · 109

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2026 Resolved
Doors in A-Class fire control boundaries must meet the following additional requirements: (3) A door must have a latch with a minimum throw of 20 millimeters (.75in). The aft main deck doors to refuge area were not latching and missing striker plate. Install striker plate and adjust the door to close to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attending vessel and inspected the installed door striker plate and witnessed proper closing of the doors.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 May 2026 Resolved
The public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system was not audible on various decks and spaces at the pier. Repair public address system to the satisfaction of the attending marine inspector within seven days. While operating with passengers on board, ensure each deck is adequetly manned to relay communications from the operating station.
Action required: 705 - Other - as specified
Due 20 May 2026
Resolved 27 May 2026
Resolution: Attend the vessel and clearly heard the PA system throughout the accommodation spaces.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2026 Resolved
At each inspection for certification, the bilges may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might clog bilge pumping systems. Presence of mud observed in lazarette bilge. Remove accumulation of mud to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended the vessel and sighted a clean and dry lazarette bilge.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 May 2026 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Door in escape route on 2nd deck was locked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended the vessel and witness the 2nd deck door to be unlocked.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 May 2026 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: "EMERGENCY EXIT, KEEP CLEAR". Aft head and galley exit missing photo luminescent marking for exit markings. Install photo luminescent emergency exit marking to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended vessel and sighted the photo luminescent exit markings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The attending marine inspector discovered a battery charger installation in lazarette that was temporarily installed into an electrical outlet. Submit plans for permanent electrical installation to the OCMI for approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended the vessel and sighted the battery charger no longer installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2026 Resolved
On vessels with no overnight accommodation; public spaces that may be assumed to be occupied by a large number of persons when passengers are on board need only be served by a manual alarm system that meets the requirements in part 76 in subchapter H of this chapter. The manual call point outside the heads had no visual and audible alarm, and not operating as designed by the manufacturer compared to the other call points that had audible and visual alarms. Repair per manufacturer specifications and to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended the vessel an observed proper operation of the manual call point outside the heads visual and audible alarm.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 May 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. The vessels crew were unable to provide evidence of holding a marine operator permit. Provide objective evidence that someone listed one the COI has a valid operator’s permit to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended the vessel and inspected the captain's radio operator permit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or equivalent. 48 doses of analgesics were expired. Replace doses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: Attended the vessel and insepcted the new analgesics quanity and expiration date.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 May 2026 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces: a space with a non-watertight closure. Bilge high level alarm in women’s head below main deck inoperable. Repair to the satisfaction of the attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 27 May 2026
Resolved 13 May 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 June 2025 Resolved
Fixed fire extinguishing system design and install must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. The fixed fire extinguishing system is inoperable and does not meet the operational requirements of the listed manual. 46 CFR 118.410(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
Resolution: Third-Party company proved proper operation of the fixed fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 June 2025 Resolved
46 CFR Part 119 contains requirements for operation of auxiliary machinery, which must be suitable for the vessel and for the purpose intended. The starboard generator does not have a started installed, will not start, and does not meet the purpose intended. 46 CFR 119.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
Resolution: Port starter motor was removed for maintenance. Started reattached and the crew started the Port generator.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 June 2025 Resolved
At each subsequent inspection for certification, the marine inspector may require that a man overboard drill be held under simulated emergency conditions. 46 CFR 115.808(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: Witnessed satisfactory man overboard drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 June 2025 Resolved
At each subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions. 46 CFR 115.810(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: Witnessed satisfactory fire drill.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2025 Resolved
Rugs and carpet may be used in addition to deck coverings. Rugs and carpets must be constructed of 100 percent wool or equivalent as determined by a flame spread rating not exceeding 75 and a smoke developed rating not exceeding 100 when tested according to ASTM E 84. Provide approval and flame spread rating for new carpet. 46 CFR 116.423(a)(4)
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: Corrected. Uploaded approval to activity.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 June 2024 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. The automatic shutdowns for the power ventilationand generators did not actuate. Vessel to provide interim written procedures for manual shutdowns of the power ventilation and generators.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
Resolution: Vessel proved proper operation of shutdowns.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: 1) A pressure type connector on each conductor; 2) A solder lug on each conductor; 3) A splice made with a pressure tyoe connector to a flexible lead or conductor; or 4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Vessel has unapproved twist-on connection :or wires near fuel tank.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
Resolution: Vessel made proper connections.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 June 2024 Resolved
A-Class bulkheads must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if the vessel is sibjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average tempreature on the unexposed side does not rise more than 250 degrees F above the original tempreature, nor does the temperature at anu one point, including any joint, rise more than 325 degrees F above the original temperature. Structural fire protection insulation on port, forward bulkhead underneath water heater is missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 18 July 2024
Resolution: Vessel replaced insulation in-kind.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 June 2024 Resolved
Except as otherwise allowed by this subject, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Aluminum hull vessels: 1) For a vessel of more that 100 feet in length-Rules for building and classing aluminum vessels, ABS; or 2) ABS guide for high speed craft. Vessel has wasted frames along forward and aft bulkgeads in galley space. Vessel to repair at next drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 7 May 2025
Resolution: Galley frames were rust busted and coated and satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 July 2023 Resolved
Door frames must be of rigid construction and provide at least a 0.5 inch overlap at the sides and top, except: Double doors capable of independent operation and latching may have a clearance between the doors of not more than 0.125 inches. However, if one door must always be closed first, means shall be provided to ensure that the doors close in the proper order. To the satisfaction of the attending MI, adjust the first second, and third deck double doors so the one door that must always be closed first does close first. 46 CFR 116.435(B)(5)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 1 September 2023
Resolution: Attended vessel and witnessed the satisfactory closing sequence of the second deck accommodation double door.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 July 2023 Resolved
When a deck scuttle serves as a means of escape, it must not be less than 455 millimeters (18 inches) in diameter and must be fitted with a quick acting release and a holdback device to hold the scuttle in an open position. The stairway from the galley to the second deck escape scuttle does not have a hold back device to hold it in the open position. Provide ans prove proper operation of the hold back device to the satisfaction of the attending MI. 46 CFR 116.500(m)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 7 August 2023
Resolution: Attended vessel and inspected the stairway from the galley to the second deck escpae scuttle hold back device installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 July 2023 Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Both generators Recor fuel filter bowls are missing a flame shield. Provide documentation that a flame shield is not required or if required, install the manufacturers approved flame shield to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2023
Resolved 7 August 2023
Resolution: Attended vessel and sighted metal filter bowls installed on generator Racor fuel filter.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 26 July 2023 Resolved
Each sewage retention device must have a means of indicating when the device is more than 3/4 full by volume. Type III sewage holding tank level indicator light on bridge is not working. Resolve to the satisfaction of the attending MI at the vessel's next dry dock in April 30, 2025. 46 CFR 121.704 33 CFR 159.83
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 7 May 2025
Resolution: Sewage/grey water indicator is operational.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 July 2023 Resolved
A fire pump must be capable of both remote operation from the operating station and local operation at the pump. Fire pump only has resets in the engine room but not local operation at the pump. Provide local operation for the fire pump in the engine room to the satisfaction of the attending MI. 46 CFR 118.300(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2023
Resolved 1 September 2023
Resolution: Attended vessel and inspected and tested local control installation of the fire pump engine room controller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Bow thruster alteration deviate from approved plans. Proposed alterations must be approved by the Marine Safety Center (MSC) before work is started. Submit bow thruster alterations plans to MSC for approval. 46 CFR 115.700
Action required: 705 - Other - as specified
Resolved 30 June 2023
Resolution: MSC E2 examined the bow thruster installation and approved. Refer to letter E2-2301829 dated May 16, 2023. MSC H2 examined the lightship characteristics and stability refer to letter H2-2302368 dated June 30, 2023, in MISLE documents work flow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 April 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Generator to be replaced in-kind this dry dock. Provide written specifications describing the details of proposed in-kind replacement of the generator for approval to the cognizant OCMI before work is started. 46 CFR 115.700
Action required: 705 - Other - as specified
Resolved 30 June 2023
Resolution: MSC H2 examined the lightship characteristics and stability refer to letter H2-2302368 dated June 30, 2023, in MISLE documents work flow.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 April 2023 Resolved
Bulkheads and decks—Bulkheads and decks must be classed as A–60, A–30, A–15, A–0, B–15, B–0, C, or C' based on the following: A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature:Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Until it can be determined that the installed structural fire protection insulation for the generators cable penetrations and main cable trunk connecting the main deck accommodation to the second deck accommodation and the main cable trunk connecting the second deck accommodation to the control station (pilot house) has a CG certificate of approval and has been installed in accordance with the manufactures specifications to the satisfaction of the attending MI the vessel will be restricted from carrying passengers. 46 CFR 116.415(2)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2023
Resolution: The CID conducted a risk assessment and decided to rescind the no-sail and issue a CG-835V permitting the MAJESTIC to operate with 150 or fewer passengers with non Coast Guard structural fire protection insulation for thirty days.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 April 2023 Resolved
Bulkheads and decks—Bulkheads and decks must be classed as A–60, A–30, A–15, A–0, B–15, B–0, C, or C' based on the following: A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature:Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Vessel passenger carriage is reduced to 150 or fewer passengers with non-approved Coast Guard structural fire protection materials for the generators cable penetrations and main cable trunk connecting the main deck accommodation to the second deck accommodation and the main cable trunk connecting the second deck accommodation to the control station (pilot house). Owner/operator provided thirty days to procure and install Coast Guard approved structural fire protection insulation in the above locations. Installation to be in accordance with the Coast Guard manufacturers type approval certificate to the satisfaction of the attending [name withheld], owner/operator to provide manufacturers Coast Guard type approval certificate and installation instructions to the attending MI. 46 CFR 116.415(2)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 29 June 2023
Resolution: Inspected Type Approved A-60 insulation adequately wrapped around the overhead cable penetrations identified. All appeared to be satisfactorily installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 July 2022 Resolved
There must be at least two sources of power for the electrical equipment of each fire detecting and alarm system. The normal source must be the main power source. The other source must be the emergency power source or an automatically charged battery. If the other source is an automatically charged battery, the charger must be supplied from the final emergency power source. Upon loss of power to the system from the normal source, the system must be automatically supplied from the other source. The fire detecting system back-up battery power supply is disconnected. Provide two sources of power for the fire detecting system IAW with approval granted by MSC Project No. P009118/Serial: E2-1701528 dated May 02, 2017. 46 CFR 113.10-9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 23 September 2022
Resolution: Attended vessel to witness industrial portable generator power fire detecting system via shore tie cable; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 July 2022 Resolved
Decks between various spaces must meet the requirements of Table 116.415(c). Vessel missing insulation above starboard engine and starboard bulkhead near fire pump. Renew insulation to original thickness and rating. 46 CFR 116.415
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Insulation above starboard engine and starboard bulkhead near fire pump renewed to original thickness and rating.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 July 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical shock. LED lighting mounted to deck railing is supplied power by a flexible cord plugged-in to receptacle outlets mounted on the main deck structure to receptacle outlets on after ladder wells. 1) Remove or make permanent lighting fixtures; 2) Provide proof the exterior lighting fixtures electrical system is less than 50 volts or it must comply with the requirements of UL 595; and 3) power LED lighting fixture with a branch circuit from a local distribution panel. 46 CFR 120.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Vessel operator removed LED lighting mounted to deck railing being supplied power by a flexible cord.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 July 2022 Resolved
For vessels required to meet the damage stability standards of subpart H of this chapter, when Class 1 doors are installed below a deck the molded line of which at its lowest point at side is less than 7 feet (2.14 meters) above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge. Indicator light on QAWTD at bulkhead 45 for access to engine room is constantly illuminated. Adjust limit switch so indicator light only illuminates when the door is opened. 46 CFR 170.255(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Attending MI witnessed indicator light on bridge illuminate when door was opened and extinguish when door was closed, proving proper adjustement of limit switch.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 July 2022 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Galley ladder leading to the deck scuttle to the main deck is not readily apparent to a person in dark conditions. Provide emergency lighting to the satisfaction of the attending MI. 46 CFR 120.432
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Vessel operator provided photograph of galley ladder illuminated with photoluminescent egress tape to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 11 July 2022 Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”, unless such markings are deemed unnecessary by the cognizant OCMI. 46 CFR 122.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Vessel operator labled engine space Class I watertight door as per 46 CFR 122.610.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 July 2022 Resolved
A framed chart or diagram must be installed in the wheelhouse or control station adjacent to the detecting cabinet indicating the location of the various detecting zones and giving instructions for the operation, maintenance, and testing of the system. This chart, or a a separate card or booklet to be kept near the chart, must have tabulated spaces for the date and signature of the licensed officer of the vessel who must witness or conduct the periodic tests. Provide. 46 CFR 76.27-80(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Vessel operator posted the smoke and fire detection plan and provided the reamining requirements for 46 CFR 76.27-80(b)(6)to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 July 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following:(2) Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detecting system to determine that the system is in operating condition; Conduct servicing of fixed fire extinguishing system in the presence of attending USCG inspector. 46 CFR 115.810(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Attending MI witnessed functional test of fixed gas fire extinguishing system to include 30 second time delay (30 second test result), siren, and pressure switches (secured both main propulsion engines and ship service generators); all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 July 2022 Resolved
Inspection and testing of smoke and fire detecting systems (including sensors and alarms) and fire confining appliances (such as fire screen doors and fire dampers). During testing of smoke detectors crew had insufficient testing smoke and crew not able to demonstrate testing of heat detectors. Crew to provide testing smoke to complete sample testing of smoke detectors in the presence of the attending MI. In addition, provide Service Company to test sampling of heat detectors in the presence of the attending MI. 46 CFR 115.810(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Attending MI witnessed sample testing of heat and smoke detectors on all deck utilzing the heat and smoke dector plan as verification; all sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 11 July 2022 Resolved
The fire detection and alarm system must notify crew and passengers of a fire when appropriate; Fire pull station for the lower aft port side head on main deck, local alarm did not sound when pulled. Repair alarm system for at this location. 46 CFR 76.27-5(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Attending MI witnessd proper operation of the fire pull station for the lower aft port side head on main deck alarm sound with strobe light when pulled.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 July 2022 Resolved
Rugs and carpets shall not extend up bulkheads or vertical surfaces more than 10 centimeters (4 inches) above the deck. Carpet extended more than 4in above the deck in the forward storage main deck space. 46 CFR 116.423(4)(I)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Carpet extended more than 4in above the deck in the forward storage main deck space has been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2022 Resolved
Each lifeline on a ring buoy must be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Aft port ring buoy lifeline was faded and frayed. Renew lifeline. 46 CFR 117.70(c)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Vessel operator provided photograph of the aft port ring buoy lifeline renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 July 2022 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow. Name of vessel missing from port bow. Mark port bow with name of vessel. 46 CFR 67.123(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2022
Resolved 10 August 2022
Resolution: Vessel operator marked vessel's name on the port bow.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 July 2022 Resolved
For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which: Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered Furniture,” or meet the requirements in § 72.05-55 in Subchapter H of this chapter. Provide test reports, manufactures certificates, or other evidence of testing to the required standards for acceptability of the Hampton Bay lawn furniture in 02 deck accommodation. 46 CFR 116.423(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 28 July 2022
Resolution: Vessel rep provided evidence the 02 deck accommodation is designated a Type 7 high risk accommodation space. High risk space furnishings are not limited to those with fire resistant construction in these spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2021 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity. The port generator lost all cooling fluid and is overheating. 46 CFR 120.310(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2021
Resolution: Port generator was repaired appropriately and an operational test was completed satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2021 Resolved
The installation requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) and subchapter J (Electrical Engineering) of this chapter. The raw water in take sensor on the stbd engine is not installed. 46 CFR 119.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: Raw water sensor was installed on the stbd engine.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2021 Resolved
The installation requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) and subchapter J (Electrical Engineering) of this chapter. The stbd generator battery has a wire connecting it to a decommissioned battery charger. Remove the decommissioned wire. 46 CFR 119.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: The stbd generator battery wire going to the decommisioned battery charger was removed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 May 2021 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a stations license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel does not have a valid Bridge-to-Bridge certificate. 46 CFR 121.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: A new valid bridge-to-bridge certificate is present onboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2021 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Current COD has the incorrect owner address. 46 CFR 67.313(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 16 July 2021
Resolution: The new and valid COD was present onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2021 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of 118.400 and 118.500 must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. The fire control panel shows a system trouble message for the panel batteries having low voltage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 14 September 2021
Resolution: Vessel received and installed a new charging circuit on the fire control panel. After installation the fire control panel showed no error messages and the battery charging circuit indicated proper charging.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 May 2021 Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classifification of accommodation and service spaces, and structural fire protection boundaries. The placement of the fire extinguishers does not match the fire control plan. 46 CFR 116.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: All fire extinguishers have been placed in accordance with the vessel's approved fire control plan.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 May 2021 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. The battery terminals in the engine compartment require cleaning and removal of wing nuts. 46 CFR 120.350(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: Battery terminals were cleaned and wing nuts were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2021 Resolved
The installation requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) and subchapter J (Electrical Engineering) of this chapter. On the aft top portion of the port generator their is a short flexible connection that is cracked and requires replacement. 46 CFR 119.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: Port generator short flexible connection was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 May 2021 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The stbd IBA is out of service and is not required for the vessels route. Remove the IBA. 46 CFR 122.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 1 July 2021
Resolution: The stbd IBA has been removed from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 August 2020 Resolved
Each vessel operating in warm water may be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. The both of the vessel’s inflatable buoyant apprentices are either not installed or passed due for servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2020
Resolution: Vessel has opted to request an amended route to less than 3 NM to remove the IBA requirement.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 August 2020 Resolved
Provisions must be made for closing all supply duct and exhaust duct openings for a space protected by a fixed gas extinguishing system. Vessels exhaust duct dampers for engine room protected by fixed CO2 do not close adequately. Supply side unable to verify. Ensure exhaust dampers close satisfactory and make supply side available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2020
Resolution: Operational test of both port and stbd exhaust dampers was performed and observed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 August 2020 Resolved
At each inspection of a vessel, the owner of managing operator shall be prepared to conduct: operation test of electrical apparatus, which operates as part of or in conjunction with a fire detection or alarm system installed on board a vessel, by simulating, as closely as practicable, the actual operation in case of fire. Vessel was unable to satisfactory test fire detectors in engine space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2020
Resolution: Vessel properly performed heat detector testing in the engine compartment using a heat gun.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020 Resolved
Unless otherwise specified in this section, the Vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years and make them available to the Coast Guard upon request. The VSO was unable to provide all of the security drill records for the previous 2 years.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: The VSO was able to produce the requested security drill records.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 August 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio LAT/LONG for DSC operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: VHF radio was installed in-kind and properly displayed the MMSI and LAT/LONG.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The main deck and O1 deck double door emergency exits have a lock that is not mechanically connected to door handle. This means that if the double doors are closed and locked a person would have to ensure that they unlock the lock before turning the door handle. From inside the space, turning the door handle should automatically unlock the lock for unobstructed emergency egress.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: The vessel removed the dead bolt locks on the double doors of the main deck and 01 deck. Dead bolt locks are not a part of their security plan.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 August 2020 Resolved
Complete but simple instructions for operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control. Vessels remote instructions do not have a labels for the pull stations, provide adequate labels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: Remote instruction labels were installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 August 2020 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high. Vessel has door to 1st passenger deck up forward missing emergency exit sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: An emergency exit sign was installed on the 1st passenger deck forward door.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 August 2020 Resolved
Decks between various spaces must meet the requirements of Table 116.415 (c). Vessel missing insulation between machinery space and accommodation space the deck above. Renew insulation to original thickness and rating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: New insulation was installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 August 2020 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Clean and gauge vicinity of stbd outboard hull plate next to first stbd longitudinal in gray water holding tank compartment
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: NDT was performed in the area and shows wastage is minimal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 August 2020 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Clean and gauge underneath the stbd stabilizer in gray water holding tank compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: NDT was performed in the area and shows wastage is minimal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld]/replace leaking water pipe on port side overhead in gray water holding tank compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 8 September 2020
Resolution: Leaking water pipe section was replaced in-kind and no longer leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2020 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The vessel reported a failure of the reduction gear on the starboard engine and inability to repair due to lack of available parts. Demonstrate repair and operation of starboard engine's reduction gear to the satisfaction of the attending marine inspector. Vessel must utilize towing vessel (s) of adequate size and horsepower when shifting between piers within Honolulu harbor until deficiency is cleared.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2020
Resolution: Witnessed operational test mode forward and reverse while underway to witness proper operation of the stbd gear box. New intermediate gear shaft was press fitted. All satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2019 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following:(2) Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detecting system to determine that the system is in operating condition; Conduct servicing of fixed fire extinguishing system in the presence of attending USCG inspector. 46 CFR 115.810(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 1 August 2019
Resolution: Servicing was completed in presence of attending MI
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2019 Resolved
he owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests:(1)For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by chapter 4 of NFPA 10 with the frequency specified by NFPA 10; Monthly inspections were not conducted on any of the portable fire extinguishers. Have qualified servicing facility conduct servicing of all portable fire extinguishers onboard. 46 CFR 115.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 24 July 2019
Resolution: Servicing was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2019 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other tan steel construction will specify if a flame shield is required; starboard main diesel engine fuel filter did not have a flame shield installed. Install flame shield in accordance with manufacturer instructions. 46 CFR 119.455
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 24 July 2019
Resolution: Fuel filter flame shield was added.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 July 2019 Resolved
The fire detection and alarm system must notify crew and passengers of a fire when appropriate; Fire pull station on the 02 deck did not sound when pulled. Repair alarm system for 02 deck. 46 CFR 76.27-5(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 1 August 2019
Resolution: Alarm system was repaired and sounded on 02 deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2019 Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits; Aft locker did not have markings. Add markings IAW 46 CFR 122.604 (f) 46 CFR 122.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 24 July 2019
Resolution: Life jackets were removed from locker
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2019 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by Table 118.500(a) of this section; Add one 40-B:C extinguishers outside of fuel tank space and two 2-A on 01 and 02 decks. 46 CFR 118.500 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 26 August 2019
Resolution: Verified installation of required portable fire extinguishers onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 July 2019 Resolved
The fire detection and alarm system must control and monitor input signals for all connected detectors and manual pull stations or call points; detection and alarm system was showing the wrong location when the pull station on the 01 deck was pulled. Repair system so that the proper space is displayed. 46 CFR 76.27-5(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 24 July 2019
Resolution: System was repaired so that the correct space is displayed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 July 2019 Resolved
Every vessel equipped with an inflatable survival craft must have approved placards or other cards containing instructions for launching and inflating inflatable survival craft for the information of persons on board posted in conspicuous places by each inflatable survival craft; vessel did not have placards posted. Add placards. 46 CFR 122.518(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 24 July 2019
Resolution: Placards were added.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 July 2019 Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries; Fire control plan was not up to date due to removal of galley fire fighting equipment. Update fire control plan to current configuration on vessel. 46 CFR 116.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2019
Resolved 26 August 2019
Resolution: Fire plan updated to reflect removal of removal of galley fire fighting equipment. Current fire control plan posted on vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2019 Resolved
Several starboard side dry dock plugs found backed out with two to three threads visible. Remove all dry dock plugs and clean for inspection by USCG.
Action required: 705 - Other - as specified
Due 8 May 2019
Resolved 9 May 2019
Resolution: Completed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2019 Resolved
Carpet found removed on deck 1 and deck 2. Operator stated that new carpet is to be installed on both decks. Provide manufacturer specificaitions for carpet USCG prior to installation.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Completed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 May 2019 Resolved
All sea chests found with marine growth. Clean marine growth and threads for sea valves for inspection by USCG.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Completed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2019 Resolved
Lighting fixture foudn fractured on deck 2 aft stairwell. Renew as original.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2019 Resolved
Exhaust leak found on port and starboard generators exhaust piping. Temporary repair putty found on exhaust piping is unsatisfactory. Renew exhaust as original.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Replaced/repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 3 May 2019 Resolved
Identified bottom plate corrosion in the bilge under the galley. Provide NDT report for affected area to be further evaluated for repair. Area to be cleaned and coated if repairs are not deemed necessary.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Completed
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 3 May 2019 Resolved
Identified one damaged and warped bulkhead, located forward fo the ladder, in the gray water tank space and two bulkheads in the bow thruster tunnel space, located forward of the bow thruster tunnel. Provide measurements to the USCG for observed damage to be further evaluated for repair.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Provided measurements
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2019 Resolved
Port and starboard main engine sea water valves found corroded. Renew as original.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Replaced/repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2019 Resolved
Aft sea keeper gate valve found corroded. Operator intends to resurface and blue fit. Replace if valve no longer meets specifications.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Replaced/repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 May 2019 Resolved
Ball valve missing for starboard engine room air breather sea valve. Renew as original.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Replaced/repaired
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 July 2018 Resolved
A class bulkheads or decks must be composed of steel...in addition, they must be so insulated with approved structural insulation. Port side engine room overhead and steering space forward bulkhead insulation is missing. 46 CFR 116.415(a)(2)(i); 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 19 September 2018
Resolution: Verified insulation installed satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2018 Resolved
All cable and wire must be installed with metal support spaced not more than 24 inches apart...the use of plastic tie wraps must be so limited to bundling...and not used as a means of support. Multiple electrical cables in engine room are missing metal supports. 46 CFR 120.340(b)(4); 50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 19 September 2018
Resolution: Verified metal supports installed every 24 inches for engine room electrical cables.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2018 Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies, must meet the requirement of 56.60-25 in Subchapter F of this chapter. Flexible nonmetallic piping found in use as sea chest vent piping does not meet Subchapter F.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 19 September 2018
Resolution: Verified temporary sea chest vent piping removed.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 17 August 2017 Resolved
Submit repair proposal for port side loss of propulsion prior to conmmencing any repairs. Proposal shall be to the satisfaction of USCG. Repairs shall be made to the satisfaction of the attanding marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 17 August 2017
Resolution: Vessel submitted repair proposal. Satisfactory repairs were made. See Docs for CG-835.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 August 2017 Resolved
Properly install structural fire insulation on bulkhead separating the fixed CO2 storage location from the machinery space. Ensure insulation has required vapor barrier and provides full coverage of the required area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 27 October 2017
Resolution: Received email photos showing new structural fire insulation installed on Aft E/R bulkhead.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 July 2017 Resolved
Ensure electrical cables are properly secured w/ metallic clamps every 24 inches. Clamps should be fitted w/ chaffe protection to avoid damaging the cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 27 September 2017
Resolution: Verified electrical cables were properly supported with metallic clamps, and that plastic zip-ties used as support means had been removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 July 2017 Resolved
Provide an emergency disconnect switch on each positive battery cable, as close to the battery as practicable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 27 October 2017
Resolution: Received photos showing new battery disconnect switches installed in the positive conductors and located adjacent to the battery banks.
Electrical › Electric Generation Source (service) › Generator
Issued 14 July 2017 Resolved
Conduct insulation resistance tests w/ a megohmeter on both ship service generators, and provide report of readings to [name withheld] must be taken to show insulation resistance between each phase, and from each phase to ground (vessel's metallic hull).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 27 September 2017
Resolution: Received meggar reviewed megger readings for both generators. Both generators insulation resistance were acceptable.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 14 July 2017 Resolved
Provide means for IBAs to be manually deployed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 21 July 2017
Resolution: Received photos of IBA stowage. Vessel added pelican hooks to the lashings for each IBA, so that each IBA can not be deployed manually as required. Also verified installation during attendance on 03AUG2017.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 14 July 2017 Resolved
Provide manual pull station for fire alarm in bridal room on upper deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 August 2017
Resolved 16 August 2017
Resolution: Verified installation and operation of manual pull station for bridal room. All sat.
Engineering › Steering Gear System › Pin
Issued 14 July 2017 Resolved
Re-install missing cotter pin for STBD rudder connecting bolt for hydraulic ram & cross bar connection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2017
Resolved 14 July 2017
Resolution: Operator re-installed cotter pin prior to completion of annual inspection. Cleared def on the spot.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 July 2017 Resolved
Properly seal penetrations in A-class bulkhead between engine room and fire fighting CO2 storage location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 27 October 2017
Resolution: Received photos of new structural fire insulation completed. Small areas near overhead that were uncovered are now covered. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 11 February 2017 Resolved
Provide repair proposal for damage sustained to port bow area prior to April 2017 dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 5 April 2017
Resolution: Def resolved during April 2017 dry dock
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 June 2016 Resolved
Install required fire detection devices in spaces with equipment listed under 46CFR 118.400(c) and in spaces listed under 46CF 118.400(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 14 June 2017
Resolution: Vessel installed required fire detection in accomodation spaces, restrooms, closets, galley and machinery space. Witnessed testing of system and verified installation to approved plans.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 6 June 2016 Resolved
Provide adequate ventilation for small battery installations located under bridge console, and for battery banks installed for vessel's gyro stabilizers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 5 April 2017
Resolution: Verified def was resolved during 2017 dry dock. Operator installed PVC pipe, connected to battery boxes as vents allowing generated hydrogen to be released to the atmosphere
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 June 2016 Resolved
Submit Non-Tank Vessel Response Plan to MSC for review and approval
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 14 July 2017
Resolution: Verified vessel had valid approved NTVRP on board.
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 6 June 2016 Resolved
Provide approved structural fire protection plan which designates top open deck area as a type 5, 6 or 7 accommodation space. Or submit fire load calcs for carpet and furnishings installed and submit new structural fire protection plan to MSC for review which designates top deck area as an accomodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 15 June 2016
Resolution: Received email correspondence from MSC allowing the installation of carpet, and furniture on the upper open deck without the need to change the space categorization. Spaces is a type 13 (open deck) space.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 May 2016 Resolved
Ensure installed time delay is fitted with the required by-pass valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 14 June 2017
Resolution: Verified new time delay is fitted with the required manual override/by-pass
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 24 May 2016 Resolved
Ensure all control devices for fixed CO2 system are located outside of the protected space. Currently the time-delay, which is required to have a by-pass valve (making it a control device) is located within the protected space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 14 June 2017
Resolution: Verified new location of CO2 storage bottles and control devices are located outside of the protected space and IAW approved plans.
Electrical › Electrical Distribution System (emergency) › Overcurrent Device
Issued 24 May 2016 Resolved
Ensure all circuit breakers are properly rated for their installed service. Currently circuit breakers used for the vessel's DC electrical system are rated for AC voltage, not DC voltage. An AC over-current device may not be able to adequately/safely open a DC current fault.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 5 April 2017
Resolution: Verified with breaker manufacturer that the Square D circuit breakers installed in the new DC panels installed for the gyro-stabilizers are rated for DC voltage.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 24 May 2016 Resolved
Repair oil and coolant leaks on Port generator. Rear oil seal on generator is leaking and oil is collecting on the underside of the turbo charger. There is also coolant leak at the back end of the generator that needs to be identified and repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 April 2017
Resolution: Verified real seal was no longer leaking during post dry dock sea trial
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 May 2016 Resolved
Provided approved Fire Control Plan
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 12 October 2017
Resolution: Received updated fire control plan. Plan routed for signature and approval stamp. All sat.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 4 May 2016 Resolved
Install approved rescue boat or request determination from OCMI to be able to recover MOB without use of a rescue boat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2016
Resolved 24 May 2016
Resolution: Witnessed satisfactory MOB recovery drill using ladder, davit and life sling. Received OCMI determination to waive rescue boat requirement.
Communications › Alarms/Indicators › High Water Alarm
Issued 4 May 2016 Resolved
Address all high level float wiring problems and install IAW CFRs
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2016
Resolved 24 May 2016
Resolution: Witnessed satisfactory testing of all high level bilge alarms.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 4 May 2016 Resolved
Re-install missing insulation on FWD Port bulkhead in engine room in way of cable run.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 24 May 2016
Resolution: Verified insulation had been reinstalled in engine room.

Casualty record · 5

2 January 2006Routine · role: Involved in a Marine Casualty · activity 2559723
6 October 2012Routine · role: Involved in a Marine Casualty · activity 4487891
2 November 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 injured · activity 6064751
11 February 2017Routine · role: Involved in a Marine Casualty · activity 6101471
2 March 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6366521
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.