Inspection history · 31
15 January 2026
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8296007
28 August 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8189038
23 October 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8023773
6 June 2024
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7889046
28 May 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7889048
22 January 2024
Internal Structural Exam · Deficiency Check · Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7852655
14 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7764220
3 August 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7771568
23 June 2023
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7724447
15 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7546609
7 August 2022
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7527634
20 July 2022
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7510997
17 July 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7512316
22 March 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411748
16 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7397203
16 November 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7352522
28 October 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7341559
4 October 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7326668
17 September 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7307777
19 April 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178555
15 October 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7077668
18 September 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7062186
25 February 2020
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6915188
9 December 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6876286
17 June 2019
COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6659968
12 September 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6535295
27 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6379459
28 August 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6249748
12 September 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5982263
8 June 2016
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5901727
1 March 2016
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5824663
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 August 2025
Resolved
All observed unsafe practices, fire hazards and other hazardous situations must be corrected. Marine Inspector observed two out of two lights in the engine room were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 8 October 2025
Resolution: Rcvd pics and cleared def
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 29 April 2024
Resolved
An exposed hazard such as gears or rotating machinery must be properly protected by a cover, guard or rail. Vessels mains were missing the guard due to a modification needed. Ensure all crew are briefed of hazard before they work on the vessel until it is replaced.
Action required: 705 - Other - as specified
Due 22 May 2024
Resolved 14 October 2024
Resolution: Cleared based on MISLE narrative and operator email (uploaded in Docs this activity)
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 29 April 2024
Resolved
Piping including valves, pipe fittings and flanges conveying vapor, gas or liquid, the temperature exceeds 150 degrees F. must be suitably insulated to prevent injuries. Hot piping in the engine room was missing insulation. Replace insulation and ensure all crew are briefed of hazard before they work on the vessel until it is replaced.
Action required: 705 - Other - as specified
Due 22 May 2024
Resolved 14 October 2024
Resolution: Cleared based on MISLE narrative and email operator provided from issuing MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 April 2024
Resolved
Each generator must be protected by an over-current device set value not exceeding 115 percent of the generator full load rating. Vessels generators were not yet programed for this. Provide technician report attesting to the satisfactory operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 14 October 2024
Resolution: Cleared based on MISLE narrative and email operator provided from issuing MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 April 2024
Resolved
During vessels pre inspection testing, the generators would not clear the fault codes during the fixed fire system shutdowns, Port generator would not clear the code at all and the starboard generator would not take a load once the code was cleared.
Troubleshoot, correct and provide technician report with the cause of the failure, the codes given the remedy and make available for CG MI to witness operational tests including; sea trials, witnessing the generators taking load and shutdowns of all engines with the fixed fire extinguishing system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2024
Resolution: Witnessed satisfactory operation
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 January 2024
Resolved
Wastage found in engine room IWO port shaft. Provide UT report of area between aft bulkhead and transverse frame concentrating on area below port shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2024
Resolution: UT report showed minimal wastage
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 January 2024
Resolved
Vessel is overdue for drydock credit which will not be given until the vessel finishes vessel repower items.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2024
Resolution: Vessel received drydock credit.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 September 2023
Resolved
The equipment required for lifefloats and bouyant apparatus must meet the following specifications: the light must be a floating waterlight approved under series 161.010 or other standard specified by the commandant. MI observed AFT STB light INOP.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 25 September 2023
Resolution: Vessel provided video of AFT STB light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2023
Resolved
Each ring life buoy on a vessel must; be approved in accordance with 160.050 in subchapter Q of this chapter or other standard specified by the commandant. MI observed PORT FWD ring life buoy line deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 25 September 2023
Resolution: Vessel provided pictures of new life ring.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 September 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. MI observed 01 crew members in safety sensitive positions, that are not enrolled in the DAPI program.
Provide proof for all crew members who perform duties and functions are enrolled in DAPI and have completed the pre-employment drug testing.
46CFR16.230(a), 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 19 September 2022
Resolution: O/O provided proof of all crew enrollment in vessels DAPI program.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 September 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Marking of life jackets is no longer legible and adult life jackets are not marked in stowage location.
46CFR180.78(a)(5), 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 19 September 2022
Resolution: O/O provided proof of proper markings and storage of adult and children's life jackets.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 September 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in
accordance with § 80.59 once every 5 years. Radio telephony certificate is expired. 47CFR80.903, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 8 February 2023
Resolution: Operator provided valid and current certificate.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 September 2022
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: A self-propelled vessel of 65 feet or more in length, engaged in commercial service. Vessel does not have an AIS.
33CFR164.46(1)(i), 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 23 June 2023
Resolution: O/O installed and proved proper operation of AIS System.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Vessel sustained damage during underway operations by way of an allision. Vessel must be made available for CG attendance and inspection of damaged areas prior to movement. 46CFR176.802
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2022
Resolution: Vessel was made available after reporting of an allision with another vessel. MI conducted a satisfactory exam of the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 October 2021
Resolved
A fixed gas extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Upon testing of the system MI discovered system did not shut down power ventilation or main engines, it did shut down the generators. Vessel to prove proper operation of all fixed gas fire suppression system shut downs prior to the carriage of passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2021
Resolution: Vessel demonstrated proper operation of all fixed gas fire suppression system shut downs. Vessel is cleared to carry passengers in accordance with its COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. Mi discovered safety hazard due to improper connection of wiring.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 October 2021
Resolution: Vessel provided proper connection prior to end of inspection. Corrected on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2021
Resolved
Annual Inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for its annual inspection. Vessel is to complete an annual inspection prior to carriage of passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2021
Resolution: Completed Annual Inspection
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 October 2020
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. 06 of 07 life floats have rotted lifeline attachment loops that are bursted. Vessel to make repairs to lifeline attachment loops. Vessel restricted to limited coastwise route within 03 miles of shore until repairs to lifeline attachment loops are made
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 March 2022
Resolution: Vessel provided all life floats in serviceable condition with all required equipment. All satisfactory. Vessel cleared to operate within full scope of COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2020
Resolved
For vessels other than those covered in paragraphs (b) and (c)of this section, the hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel to provide hailing port of stern of vessel in at least four inch letters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 5 February 2021
Resolution: Vessel painted hailing port on stern.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 September 2020
Resolved
Vessel may not carry passengers until satisfactory completion of annual COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2020
Resolution: Successfully completed annual COI.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 June 2019
Resolved
EACH LINK CERTIFIED BY THE MANUFACTURER TO MEET THE REQUIREMENTS OF THIS SUB PART MUST HAVE A CORROSION RESISTANT WATERPROOF TAG ATTACHED TO IT. TAGS ON LIFERAFT WEAK LINKS WASTED, UNABLE TO VERIFY BREAKING STRENGTH. PROPVE BREAKING STRENGTH AND PROPER INSTALLATION.
46 CFR 160.073-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 16 August 2019
Resolution: New weak link with tag installed.
Lifesaving › Hand Flares › Quantity
Issued 28 August 2017
Resolved
Provide one additional hand orange smoke distress signal (5 onboard, 6 required).
Condition: Invalid
Due 28 August 2017
Resolved 28 August 2017
Resolution: Corrected on the spot.
Lifesaving › Hand Flares › Quantity
Issued 28 August 2017
Resolved
Provide one additional hand red flare distress signal (5 onboard, 6 required).
Condition: Invalid
Due 28 August 2017
Resolved 28 August 2017
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 August 2017
Resolved
Provide three additional adult life jackets.
Condition: Invalid
Due 28 August 2017
Resolved 28 August 2017
Resolution: Corrected on the spot.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 August 2017
Resolved
Label Visual and Audible alarm panel for bilge high level.
Condition: Invalid
Due 28 August 2017
Resolved 28 August 2017
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 March 2016
Resolved
Make handrails on back deck swim step proper strength.
Action required: 705 - Other - as specified
Resolved 28 April 2016
Resolution: Rails were installed and of proper strength
Construction/Loadline › Hull › Bottom Plating
Issued 2 March 2016
Resolved
Prove current hull thickness. Any areas of appreciable waste shall be cropped out and renewed to original scantling. Submit plan to this office prior to beginning repair work.
Action required: 705 - Other - as specified
Resolved 30 April 2016
Resolution: Repairs made, hull watertight, credit hull/ISE given
Construction/Loadline › Hull › Bottom Plating
Issued 2 March 2016
Resolved
Make all interior spaces available for inspecion.
Action required: 705 - Other - as specified
Resolved 3 March 2016
Resolution: All interior spaces clear for inspection.
Stability › Watertight Integrity › General
Issued 2 March 2016
Resolved
Provide original scantlings
Action required: 705 - Other - as specified
Resolved 3 March 2016
Resolution: Recieved scantlings from owner