Registered dimensions (L × B × D)45.5 ft × 15.9 ft × 2.4 ft
Registered tonnagegross 46 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHYDRODYNE MARINE CORP. · PORT HUENEME, CA, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 27 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton 38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 26 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2025Resolved
Guards for exposed hazards such as rotating machinery must be protected by a guard, cover or rail. Generator pulleys are exposed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2025
Resolved 19 February 2026
Resolution: Marine Inspector observed the generator pulleys are protected by a guard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 February 2023Resolved
On a vessel of not more than 19.8 meters (65feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414kPa (60psi) at the pump outlet. Vessel's fire pump only produced 40 psi. Vessel is restricted to carrying less than 49 passengers. Repair/replace fire pump to produce 60 psi to the satisfaction of the attending USCG marine inspector.
Action required: 705 - Other - as specified
Resolved 24 April 2023
Resolution: Installed new pump and expanded sea suction thru hull fitting. MI observed steady water stream from fire hose and 80+ psi at fire pump gauge.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 March 2022Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers,.. the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet.
MI observed fire pump only attain 20 PSI and never achieve an effective stream of water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2022
Resolved 20 April 2022
Resolution: O/O replaced fire pump and proved proper operation.
A vessel to which this sub-chapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel is over due for a COI examination. Vessel is prohibited from carrying passengers for hire until a COI exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2021
Resolved 5 March 2021
Resolution: Completed COI Inspection.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 October 2020Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Paper charts were not available on board the vessel.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 2 November 2020
Resolution: Charts verified to be onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2020Resolved
Each life jacket must be marked in clearly legible block capital letters with vessel's name. Four life jackets stowed on the second deck were not marked with the vessel's name.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2020
Resolved 16 October 2020
Resolution: Life Jackets (Vest PFD) properly marked with name of vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2020Resolved
Receptacle outlets and attachment plugs for portable lamps, tools, and similar apparatus operating at 100 volts or more, must have a grounding pole and a grounding conductor in the portable cord. Several outlets were found to have open grounds. Locations include second deck passenger space, pilot house, galley area, and lower deck passenger space.
46 CFR 183.370(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 2 November 2020
Resolution: Open electrical grounds rectified; properly bonded to grounding wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2020Resolved
Each distribution panel or switch-board must be totally enclosed and of the dead front type. The breaker panel within the generator space (port side) was found to have an open slot (i.e. missing blank).
46 CFR 183.330(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 2 November 2020
Resolution: Blanks (covers) installed to protect against unintentional contact.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2019Resolved
Propulsion machinery shall be capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel to prove proper operation of the port MDE after suffering a Loss of propulsion to the port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2019
Resolution: Vessel completed satifactory sea trials to prove proper operation of main propulsion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2019Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of propulsion. Vessel required to prove proper operation of the propulsion system to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2019
Resolved 29 June 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2019Resolved
Missing flame shield to generator fuel filter. Non metallic fuel bowls will provide a flame shield protecting fuel bowl. Provide flame shield for fuel filter assembly.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 7 May 2019
Resolution: provided flame shield for fuel bowl.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2019Resolved
Missing placard or markings for max occupancy for top deck. Provide proper placard or markings.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 23 April 2019
Resolution: Provided correct placard/sign and installed on top deck in plain veiw for passengers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2018Resolved
Prove proper operation of port engine. Engine was not going in & out of gear (fwd/rvs) reliably.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2018
Resolution: Conducted satisfactory operational test of the vessel's port engine.
Construction/Loadline › Hull › Keel
Issued 8 March 2017Resolved
Pull 01 keel bolt from any location for inspection.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 15 March 2017
Resolution: Pulled keel bolt was in satisfactory condition. No further action required.
Construction/Loadline › Structures › Deck Plating
Issued 8 March 2017Resolved
Treat/repair rot in forward compartment where indicated.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 15 March 2017
Resolution: Repairs made to the satisfaction of the attending marine inspector.
Stability › Watertight Integrity › General
Issued 8 March 2017Resolved
Conduct satisfactory sea-trial prior to credit drydock/carrying passengers.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 5 April 2017
Resolution: Vessel conducted satisfactory sea-trial.