LEXINGTON

LEXINGTON is a 1987 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1987, most recently in November 2025, along with 118 deficiencies and 2 casualty investigations between 2012 and 2020.

Records from 1987 to 2025. Most recent: inspection, 24 November 2025.

Built
1987
Last inspected
24 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB6444
286478
Flag
UNITED STATES
366924480
Maury page id
psix-286478

Inspections, by type

…with no type recorded5
Years with a record 36 calendar years (1987–2025)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)70.0 ft × 30.2 ft × 7.0 ft
Registered tonnagegross 69 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPHOENIX SHIPBUILDING CO · PORT JEFFERSON NY, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB6444MMSI 366924480 · active · compulsorily equipped · granted 2 February 2024, expires 10 February 2034
WTL7785MMSI not assigned · expired · compulsorily equipped · granted 9 June 1997, cancelled 6 October 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HENRY LONGFELLOW Passenger (Inspected) · MISLE 437122 · 3 November 2004 · activity 2233827

Inspection history · 72

24 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8272281
13 November 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8256499
30 October 2024 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8025672
25 April 2024 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7902069
18 January 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7847482
20 November 2023 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7825265
26 April 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668544
28 March 2023 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7657510
28 February 2022 Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7400775
2 December 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7349739
1 June 2021 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7272687
18 November 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7098494
12 September 2020 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7056898
12 September 2020 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7059487
11 December 2019 Hull Examination · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6872989
15 October 2019 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6832864
19 November 2018 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6583461
6 November 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6575101
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537994
17 November 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6308251
14 April 2017 Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6126978
20 October 2016 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6025897
21 October 2015 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5747505
23 October 2014 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5010092
28 May 2014 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4872124
3 July 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4368414
14 December 2010 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3910562
4 November 2010 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3885426
12 February 2010 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3679226
4 December 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3374139
15 October 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3345036
31 October 2007 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3090346
27 February 2007 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2878613
10 January 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2563893
2 May 2005 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2347483
6 December 2004 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2253918
12 November 2004 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2239641
3 November 2004 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2233827
16 December 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1964837
2 July 2003 Excursion Permit · Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1833748
21 January 2003 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1728097
19 September 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1708157
30 July 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1654205
4 July 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1643246
30 May 2002 Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1707708
26 June 2001 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1406976
16 May 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1414006
15 September 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822509
15 August 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423426
24 June 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464196
24 June 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464197
25 August 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1131938
12 August 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1117604
25 June 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 777092
25 June 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1089311
22 June 1995 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190246
21 June 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333757
22 June 1993 Hull Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157435
18 June 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845670
25 June 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255435
18 May 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944286
16 May 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223937
7 May 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222569
26 March 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221228
6 November 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907190
27 September 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926406
14 August 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926275
25 April 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214829
30 May 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039549
31 March 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036744
16 November 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 892731
28 October 1987 Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003506

Deficiency record · 118

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2025 Resolved
Each fire hose nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Upper deck fire hose nozzle could not be changed from spray pattern to solid stream. 46 CFR 181.320(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2025
Resolution: Received evidence of nozzle replacement with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 15 Kapok adult life jackets were found deteriorated and incapable of repair; 1 crew adult life jacket modified for man overboard recovery. 705: Total number of persons allowed on board reduced to 138, the number of servicable adult life jackets on board. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 17 November 2025
Resolution: 17 new Type I PFDs purchased and placed aboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 October 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not possess placards for all types of life jackets on board. Post placards containing donning instructions for all types of life jackets on board to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel installed required placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 October 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Space containing children size life jackets was not labeled. Label space to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel created proper marking for life jackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2024 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Replace all combustible waste receptacles with noncombustible waste receptacles to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Attended vessel for def check. Witnesses satifactory corrections. Vessel replaced all combustible trash receptacles with noncombustible trash receptacles.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 October 2024 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens and meet the requirements of 46 CFR 84.15. Vessel is greater than 20 meters and the sidelights are not fitted with matte black inboard screens. - 46 CFR 84.05(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel corrected nav lights. See documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Grab lines on ring buoys are deteriorated. Renew grab lines to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel replaced ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2024 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. Battery in ring buoy light is expired. Replace to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel replaced battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. STBD generator had excessive oil in is drip pan and windings that need to be cleaned. Repairs/Clearing and/or replacement is required. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2024
Resolved 3 April 2024
Resolution: Rep installed new generator, MI verify an KW/KVA and Aggregate Weight Change was replaced-in-kind/within the 2% allowable weight change.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 January 2024 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10. 46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 18 January 2024
Resolved 18 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 January 2024 Resolved
Each buoyant apparatus must have Type II retro-reflective material meeting subpart 164.018 of this chapter on each side and end. All buoyant apparatuses have worn/missing retro-reflective tape that needs to be installed/replaced. 46 CFR 160.010-4(p)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: MI witness/verified all life rings are SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2024 Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Both MDE's were missing lagging at the beginning connection point of the exhaust manifold and at all connection bolts. Guards/Lagging are required to prevent crew injuries. 46 CFR 182.20-20 46 CFR 182.15-20(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: MI witness/verified that lagging was installed on both exhaust Manifolds.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Receptacle in the center of the engine room between the MDEs was missing its cover, allowing access to electrical hazards. 46 CFR 183.01-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: Recepticle/cover was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Both MDE's have belt driven pump (bilge pump and fire pump) without guards. Exposing crew to possible injury from rotating machinery. Guards must be provided. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2024
Resolved 3 April 2024
Resolution: Guards were added to both MDE belt areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 January 2024 Resolved
Mechanically propelled "S" vessels which are ferry vessels or which carry more than 49 passengers and mechanically propelled "L" vessels shall comply with the provisions of Sub-chapter F of this chapter. Nonmetallic flexible hose may be used in lengths not exceeding 76 cm (30 inches) where flexibility is required. Forepeak bilge connection in the engine room from the bulkhead to a stop valve has a straight nonmetallic flexible hose where flexibility is not required. All other bilge connections in the engine room are metallic. Remove nonmetallic flexible hose and install metallic pipe connection or provide MI with justification for its presence. 46 CFR 182.40-5(b) 46 CFR 56.60-25(b)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: See "Deficiency Documents" for Rep's reasoning, MI satisfied with explanation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2023 Resolved
A propulsion engine control system, including pilothouse control, must be designed so that a loss of power to the control system does not result in an increase in shaft speed or propeller pitch. Submit Qualitative Failure Analysis (QFA) and Design Verification Test Procedures (DVTP) of the vessel's propulsion engine control system for loss of power.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2023
Resolved 25 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel must submit plans for re-power of both main engines. Once plans are submitted to Marine Safety Center and approved, marine inspector will attend to test approved plans for main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 April 2023
Resolution: Vessel has approved re-power plans from MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2020 Resolved
Propulsion machinery shall be capable of operating at constant marine load without exceeding it's designed limitations. Port side propulsion system is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2021
Resolution: Appropriate repairs were made. Sea trials conducted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2020 Resolved
Propulsion machinery shall be capable of operating at constant marine load without exceeding it's designed limitations. Port and starboard paddle wheels are both missing blades.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 June 2021
Resolution: New paddle wheels were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 October 2019 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Port engine is missing its guard for the fire pump belt.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 21 October 2019
Resolution: Received a photo showing a guard around the firepump belt.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 October 2019 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. In the machinery space, sealant used for each watertight bulkhead penetration (on both bulkheads) is worn, making the penetrations not watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Crew member plugged all penetrations with watertight sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 02 lifejackets were condemned during inspection and another 02 lifejackets were missing from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Crewmember landed 04 new life jackets on board during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2018 Resolved
An adult life jacket must be provided for each person onboard vessel. 17 life jackets condemned. Vessel restricted to 137 persons. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 November 2018
Resolution: New lifejackets purchased.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: Verified static draft was updated.
Construction/Loadline › Structures › Air Pipe
Issued 17 November 2017 Resolved
Found gooseneck for forepeak wasted through. Provide permanent repair.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2018
Resolution: Repair complete.
Lifesaving › Lifebuoys › Serviceable
Issued 17 November 2017 Resolved
Replace 01 life ring on portside.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 30 November 2017
Resolution: Replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2017 Resolved
Label 01 lifering on stbd side.
Condition: Invalid
Due 24 November 2017
Resolved 30 November 2017
Resolution: Labeled.
Fire Fighting › Fire Main › Condition
Issued 20 October 2016 Resolved
Fire main branch line found with pin hole leak. Replace piping.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Resolution: New fire main branch line installed.
Engineering › Bilge Water Management System › Manifold
Issued 20 October 2016 Resolved
Bilge manifold not labeled. Label each individual bilge line.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 30 November 2016
Resolution: Bilge labled
Construction/Loadline › Penetrations › Gasket
Issued 20 October 2016 Resolved
Gasket on forward hatch worn. Replace gasket.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 15 December 2016
Resolution: New gasket installed.
Construction/Loadline › Structures › Manhole
Issued 20 October 2016 Resolved
Two emergency escape hatches were not labeled. Label each hatch on both sides, 1 inch lettering, "EMERGENCY HATCH, KEEP CLEAR"
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 30 November 2016
Resolution: Labled.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 October 2016 Resolved
Total persons allowed is limited to 152 persons until two life jackets are added.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 10 November 2016
Resolution: Vessel rep. aquired two new life jackets.
Fire Fighting › Fire Pumps › Pressure
Issued 20 October 2016 Resolved
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Vessel rep. proved proper operation of vessels fire pump.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 October 2014 Resolved
Vessel is missing 6 lifejackets. Vessel is restricted to carrying 148 total persons onboard.
Action required: 705 - Other - as specified
Resolved 24 October 2014
Resolution: Vessel purchased 6 new adult size PFD''s.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 October 2014 Resolved
Ladder has broken rungs in the forepeak and need to be replaced/repaired. 46 CFR 176.05-10(a)
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 20 November 2014
Resolution: Received photo of replaced ladder rungs. SAT.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 October 2014 Resolved
Underway man overboard and fire drills were not conducted due to inclement weather. u/w drills will be conducted prior to 31May15.
Action required: 705 - Other - as specified
Due 31 May 2015
Resolved 18 May 2015
Resolution: Conducted man overboard drill and fire drill, all sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 January 2006 Resolved
Install insulation on port and stbd main engine exhausts.
Condition: Improper Installation
Due 9 February 2006
Resolved 21 February 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 10 January 2006 Resolved
Renew port and stbd alternator brackets to protect from excessive vibration.
Due 9 February 2006
Resolved 21 February 2006
Documentation › Certificates/Documents › FCC SSL
Issued 10 January 2006 Resolved
Provide proof of current FCC Radio Safety Certificate.
Due 9 February 2006
Resolved 21 February 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 January 2006 Resolved
Provide 22 adult lifejackets and one child lifejacket to replace failed/missing lifejackets. Vessel capacity reduced to 127 passengers until requirement cleared.
Due 9 February 2006
Resolved 21 February 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 November 2004 Resolved
Service fixed FE 241 fire extinguishing system for the furnace compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2004
Resolved 14 December 2004
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 12 November 2004 Resolved
Lag generator exhaust piping on port and starboard prime movers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 24 November 2004
Construction/Loadline › Structures › Scuttle
Issued 12 November 2004 Resolved
Provide a captive chain to hull vice attachment to a copper pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 24 November 2004
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 12 November 2004 Resolved
Obtain a valid FCC Safety Radiotelephony Certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 24 November 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 November 2004 Resolved
Prior to operating next season (2005) conduct underway man overboard and fire drills with vessel's crew.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 2 May 2005
Resolution: Witnessed satisfactory fire and man overboard drills with crew members.
Documentation › Certificates/Documents
Issued 16 December 2003 Resolved
Provide a current FCC Safety Radiotelephone Certificate. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined new certificate.
Documentation › Safety/Response Plans/Programs
Issued 16 December 2003 Resolved
Provide and post a written waste management plan LEGACY COMPONENT DESC: Waste Management Plan
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined satisfactory Waste Management Plan.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 December 2003 Resolved
Provide 12 additional adult Type 1 PFDs for a total of 154. Until completed, vessel capacity is limited to 142 total persons. 10Feb2004: Extended compliance date to 30Apr2004. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 3 December 2004
Lifesaving › Lifebuoys
Issued 16 December 2003 Resolved
Prior to carrying passengers, provide a minimum of 60 ft of UV resistant line for at least one ring lifebuoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined satisfactory life line for port ring life buoy.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 December 2003 Resolved
Provide approved mounting brackets for all portable fire extinguishers. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined staisfactory brackets for portable fire extinguishers.
Accommodation/Occupational Safety › Heating
Issued 16 December 2003 Resolved
Provide plans for review for newly installed oil-fired furnace and propsed fixed fire fighting system to Marine Safety Office Boston. LEGACY COMPONENT DESC: Burners
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Satisfactory plan received 02Feb2004. Examined installation and for satisfactory this date.
Engineering › Bilge Water Management System
Issued 16 December 2003 Resolved
Label valves on bilge manifold and provide and post instructions for use of the system. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined bilge manifold labling and instruction and found them satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2003 Resolved
Secure sight box for starboard paddle wheel on 01 deck. The paddle wheel well must be inaccessible to passengers. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Stbd paddle wheel sight box examined and found secured.
Construction/Loadline › Structures
Issued 16 December 2003 Resolved
Prior to carrying passengers, repair all dogs on hatch covers for forepeak and #2 void. LEGACY COMPONENT DESC: Scuttle
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2004
Resolved 10 February 2004
Resolution: Witnessed satisfactory test of hatch closure/dogging.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2003 Resolved
Secure all CO2 bottles for soft drink dispensing system.
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined soft drink CO2 bottles and found them satisfactorily secured.
Electrical › Electric Supply System (service)
Issued 16 December 2003 Resolved
Secure box and provide cover for starboard generator start batteries. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 10 February 2004
Resolution: Examined battery boxes and found them satisfactorily secured.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 December 2003 Resolved
Prior to carrying passengers, prove ability to successfully recover a man overboard using ladder and rescue sling in combination. Crew was not trained in the use of the rescue sling and could not recover an incapacitated or unconscious person using only the ladder. Extended to 30Apr2004. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2004
Resolved 3 December 2004
Documentation
Issued 26 June 2001 Resolved
Provide a copy of the current Certificate of Documentation current owner info and vessel name.
Condition: Unknown
Due 26 July 2001
Resolved 19 September 2002
Engineering
Issued 26 June 2001 Resolved
Prove proper operation of starboard main engine tachometer located in pilothouse.
Condition: Unknown
Due 26 July 2001
Resolved 19 September 2002
Engineering
Issued 26 June 2001 Resolved
Provide flame screen with 30 x 30 mesh for sewage vent.
Condition: Unknown
Due 26 July 2001
Resolved 19 September 2002
Electrical
Issued 26 June 2001 Resolved
Provide shock resistant electrical matting in front of main switchboard.
Condition: Unknown
Due 26 July 2001
Resolved 19 September 2002
Fire Fighting
Issued 26 June 2001 Resolved
Provide ventilation closure devices for engine room vents.
Condition: Unknown
Due 26 July 2001
Resolved 19 September 2002
Fire Fighting
Issued 26 June 2001 Resolved
Prove 60 psi discharge pressure capability for main fire pump.
Condition: Unknown
Due 26 July 2001
Resolved 19 September 2002
Electrical
Issued 15 September 2000 Resolved
Provide a permenantly mounted shore tie receptacle for the vessel in accordance with 46CFR183.390. (Existing vessel - "old" T - 46CFR183.10-50)_x001C_ This requirement is to reissue and clarify NY02 of MI00025402 dtd 15Aug00.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Electrical
Issued 15 August 2000 Resolved
PROVIDE MECHANICAL INTERLOCK FOR GENERATOR BREAKERS TO PREVENT SIMULTANIOUSCONNECTION TO THE SWITCHBOARD, IAW 46 CFR 183.322(b).
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Construction/Loadline
Issued 15 August 2000 Resolved
REPAIR HATCH SECURING MECHANISMS FOR SCUTTLES TO COMPTS 1 AND 2, IAW 46 CFR179.360.
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Engineering
Issued 15 August 2000 Resolved
PROVIDE DOUBLE HOSE CLAMPS ON ALL FLEX-HOSE CONNECTIONS TO VITAL SYSTEMS INTHE ENGINE ROOM, IAW 46 CFR 182.720(e)(3)(v)(B).
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Electrical
Issued 15 August 2000 Resolved
PROVIDE A PROPER, UNSPLICED SHORE TIE CABLE FOR THE VESSEL, IAW 46 CFR 183.200(b).
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 24 June 1999 Resolved
INSTALL RETRO TYPE II TO ALL LIFE RINGS IN FOUR PLACES AS INDICATED ON 835
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 24 June 1999 Resolved
REPLACE BROKEN SWITCH COVER IN GALLEY ABOVE STBD SIDE SINK
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 24 June 1999 Resolved
INSTALL METAL SUSPENSION EVERY 24 INCHES FOR WIRE RUN'S IN ENG ROOM
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Lifesaving
Issued 24 June 1999 Resolved
ENSURE ALL CANDLE BASES ARE SECURED TO BULKHEAD. FOUND SEVERAL LOOSE DURING INSPECTION.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Engineering
Issued 24 June 1999 Resolved
REPLACE PADDLE WHEEL BLADES AS NEEDED AND INSTALL NEW HARDWARE AS NEEDED
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Accommodation/Occupational Safety
Issued 24 June 1999 Resolved
SALT WATER INTAKE VALVE FOR MSD-REMOVE (DUE TO BEING PVC) AND REPLACE WITH A METAL VALVE.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 24 June 1999 Resolved
VOID 6 (GALLEY) REPLACE MISSING GLOBE ON LIGHT IN VOID, CAGE WAS INSTALLEDDURING INSPECTION
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
INSTALL A BALL VALVE OR CHECK VALVE FOR SINK OVBD DISCHARGE-LOCATED IN LAZ ON BOTTOM PLATE UPPER PART STBD SIDE.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Lifesaving
Issued 24 June 1999 Resolved
PROVIDE RESCUE BOAT FOR MAN OVERBOARD RECOVERY OR SUBMIT PROPOSAL FOR USE OF A RESCUE PLATFORM (LADDER) TO ENCLUDE PROCEDURES, TYPE OF COMMUNICATION WITH CREW, AND RETRIEVAL OF UNCONCIOUS PERSON. RECOMMEND STBD BOW USING A LADDER AND THE DAVIT INSTALLED WITH A RESCUE COLLAR/HOIST
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 24 June 1999 Resolved
REPLACE OUTLET SOCKET IWO EMERGENCY FUEL SHUT OFF STBD SIDE
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
INSTALL CHECK VALVES ON BILGE PIPING SYSTEM BEHIND EACH STRAINER, NONE WERENOTED IN ENTIRE SYSTEM
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
MAKE BULKHEAD PENATRATION FOR SODA FOUNTAIN LINES IN AFT ENG ROOM BULHEAD AND AFT BULHHEAD OF VOID 6 TO MSD TANK (COPPER LINES) WATER TIGHT
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Documentation
Issued 24 June 1999 Resolved
PROVIDE CURRENT CHARTS, COAST PILOT, AND TIDE TABLES
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 24 June 1999 Resolved
VOID #6 (GALLEY) REMOVE JUNCTION BOX WITH EXTENSION CORD SUPPLYING POWER AND PROPERLY WIRE JUNCTION BOX AND OUTLET.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 24 June 1999 Resolved
INSPECT STUFFING TUBES AND MAKE WATERTIGHT IN ENG ROOM, FWD AND AFT BULKHEADS AND LAZ FWD BULKHEAD
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
LABLE ALL EMERGENCY ESCAPE HATCHES "EMERGENCY ESCAPE KEEP CLEAR"
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 24 June 1999 Resolved
REPLACE PORT AFT MAIN DECK FIRE HOSE, HOLE IN FITTING
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Engineering
Issued 24 June 1999 Resolved
PORT SIDE PADDLE WHEEL: REPAIR BOLT ON OUTSIDE HUB (BOLT APPEARS CROSS THREADED)
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999 Resolved
SUBMIT FOR APPROVAL HIGH LEVEL BILGE ALARM SYSTEM, TO INCLUDE MAKE/MOD, TYPE OF WIRE AND SIZE USED, TYPE/MOD OF FLOAT SWICH.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Documentation
Issued 25 August 1998 Resolved
PROVIDE AND POST FCC RADIO SAFETY TELEPHONEY CERTIFICATE. VESSEL RESTRICTED TO NMT 1000 FEET FROM SHORE UNTIL CLEARED.
Condition: Unknown
Due 15 September 1998
Resolved 17 September 1998
Fire Fighting
Issued 25 August 1998 Resolved
PROVIDE 1 B-II FIRE EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 September 1998
Resolved 3 September 1998
Lifesaving
Issued 12 August 1997 Resolved
PROVIDE 2 CHILD PFD'S. VESSELS CARRYING CAPACITY REDUCED TO 14 CHILDREN AND 158 ADULTS UNTIL CLEARED.
Condition: Unknown
Due 1 September 1997
Resolved 8 September 1997
Navigation
Issued 12 August 1997 Resolved
PROVE PROPER OPERATION OF RADAR.
Condition: Unknown
Due 1 September 1997
Resolved 21 October 1997
Fire Fighting
Issued 12 August 1997 Resolved
SHOW PROOF OF 12 YEAR HYDRO TESTING ON ALL FIRE EXTINGUSHERS. 1 B-I AND 5 B-II'S. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 13 August 1997
Resolved 8 September 1997
Unknown
Issued 12 August 1997 Resolved
PROVIDE AND POST AN EMERGENCY BROADCAST PLACARD NEXT TO RADIO TRANSMIT EQUIPMENT.
Condition: Unknown
Due 1 September 1997
Resolved 12 September 1997
Lifesaving
Issued 12 August 1997 Resolved
PUT SHIPS NAME ON ALL RING BUOYS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 13 August 1997
Resolved 8 September 1997
Lifesaving
Issued 25 June 1996 Resolved
INSTALL RETRO REFLECTIVE TAPE ON ALL (THREE) LIFE RINGS.
Condition: Unknown
Due 25 June 1996
Resolved 15 July 1996
Lifesaving
Issued 25 June 1996 Resolved
POST EMERGENCY CHECK OFF LIST
Condition: Unknown
Due 25 June 1996
Resolved 15 July 1996
Documentation
Issued 25 June 1996 Resolved
PROVIDE CHEMICAL TESTING POLICY REQUIRED UNDER 46 CFR 16
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 21 June 1994 Resolved
PROVIDE AND INSTALL PROPER FLAME SCREENS ON P & S F/O VENTS. THIS REQUIREMENT PREVENTS THE VSL FROM OPERATION UNTIL SATISFIED. THIS REQ CAN BE CLEARED VIA A WRITTEN STATEMENT FROM THE LIC MASTER OF THE VSL.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Accommodation/Occupational Safety
Issued 21 June 1994 Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Documentation
Issued 21 June 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Documentation
Issued 22 June 1993 Resolved
PROPERLY LABEL EMERGENCY ESCAPE HATCH IN ICE ROOM.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Lifesaving
Issued 22 June 1993 Resolved
PROVIDE FOUR ADULT AND TWO CHILD SIZE LIFE PRESERVERS TO BRING TOTAL TO 158ADULT, 16 CHILD. PASSENGER CAPACITY IS LIMITED TO 140 ADULT, 14 CHILD UNTILTHIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Fire Fighting
Issued 22 June 1993 Resolved
PROVIDE SECOND FIRE HYDRANT AS REQUIRED NO LATER THAN 2 JULY 1993 TO THE SATISFACTION OF AN ATTENDING MARINE. INSPECTOR.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Documentation
Issued 22 June 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Electrical
Issued 22 June 1993 Resolved
REPLACE MISSING METAL GUARDS (3) ON LIGHT FIXTURES IN ENGINE ROOM.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Documentation
Issued 22 June 1993 Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Construction/Loadline
Issued 18 May 1992 Resolved
SECURE HATCHS (OUTSIDE HATCHES) TO VESSEL.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Construction/Loadline
Issued 18 May 1992 Resolved
MAKE THROUGH BULKHEAD FITTING WATER TIGHT BETWEEN ENGINE ROOM AND THE ICE ROOM.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Lifesaving
Issued 25 April 1990 Resolved
PROVIDE 8 APPROVED LIFE PRESERVERS. VESSEL IS RESTRICTED TO 150 TOTAL PERSONS UNTIL COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Construction/Loadline
Issued 25 April 1990 Resolved
INSTALL SCREW DOWN VALVE IN WAY OF COLLISION BULKHEAD AS PER 46 CFR 182.25-5(D).
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Accommodation/Occupational Safety
Issued 25 April 1990 Resolved
OBTAIN USCG APPROVED PLANS FOR TEMPORARY SEWAGE BLADDER IN #2 COMPARTMENT PRIOR TO ITS USE.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Lifesaving
Issued 28 October 1987 Resolved
PROVIDE 18 ADDITIONAL ADULT PFD'S AND 1-CHILD PFD.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Construction/Loadline
Issued 28 October 1987 Resolved
VEE AND WELD AFT SIDE OF INSERT AT AFT BHD OF ENGINE ROOM.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Electrical
Issued 28 October 1987 Resolved
INSTALL METAL WIRE HANGER ON WIRE RUNS IN MACHINERY SPACES.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Lifesaving
Issued 28 October 1987 Resolved
PROVIDE STORAGE FOR ADDITIONAL 18 ADULT PFD'S AND 1 CHILD PFD.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987 Resolved
INSTALL ISOLATION CHECK VALVES AT PORT AND STBD BILGE PUMPS.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987 Resolved
PROVIDE APPROVED PLANS FOR BILGE MANIFOLD SYSTEM "AS BUILT".
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987 Resolved
SECURE FUEL LINES WITH SUITABLE PIPE HANGERS AT FWD END OF ENGINE ROOM.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987

Casualty record · 2

3 July 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4368414
12 September 2020Routine · role: Involved in a Marine Casualty · activity 7056898
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.