Records from 2012 to 2025. Most recent: inspection, 24 November 2025.
Inspection history · 22
24 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8272281
13 November 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8256499
30 October 2024
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8025672
25 April 2024
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7902069
18 January 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7847482
20 November 2023
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7825265
26 April 2023
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668544
28 March 2023
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7657510
28 February 2022
Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7400775
2 December 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7349739
1 June 2021
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7272687
18 November 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7098494
12 September 2020
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7056898
12 September 2020
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7059487
11 December 2019
Hull Examination · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6872989
15 October 2019
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6832864
19 November 2018
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6583461
6 November 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6575101
11 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6537994
17 November 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6308251
14 April 2017
Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6126978
20 October 2016
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6025897
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2025
Resolved
Each fire hose nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Upper deck fire hose nozzle could not be changed from spray pattern to solid stream.
46 CFR 181.320(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2025
Resolution: Received evidence of nozzle replacement with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 15 Kapok adult life jackets were found deteriorated and incapable of repair; 1 crew adult life jacket modified for man overboard recovery. 705: Total number of persons allowed on board reduced to 138, the number of servicable adult life jackets on board.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 17 November 2025
Resolution: 17 new Type I PFDs purchased and placed aboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 October 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not possess placards for all types of life jackets on board.
Post placards containing donning instructions for all types of life jackets on board to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel installed required placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 October 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Space containing children size life jackets was not labeled. Label space to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel created proper marking for life jackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2024
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Replace all combustible waste receptacles with noncombustible waste receptacles to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Attended vessel for def check. Witnesses satifactory corrections. Vessel replaced all combustible trash receptacles with noncombustible trash receptacles.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 October 2024
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens and meet the requirements of 46 CFR 84.15. Vessel is greater than 20 meters and the sidelights are not fitted with matte black inboard screens. - 46 CFR 84.05(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel corrected nav lights. See documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Grab lines on ring buoys are deteriorated. Renew grab lines to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel replaced ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2024
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. Battery in ring buoy light is expired. Replace to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 5 December 2024
Resolution: Vessel replaced battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. STBD generator had excessive oil in is drip pan and windings that need to be cleaned. Repairs/Clearing and/or replacement is required.
46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2024
Resolved 3 April 2024
Resolution: Rep installed new generator, MI verify an KW/KVA and Aggregate Weight Change was replaced-in-kind/within the 2% allowable weight change.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 January 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10.
46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 18 January 2024
Resolved 18 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 January 2024
Resolved
Each buoyant apparatus must have Type II retro-reflective material meeting subpart 164.018 of this chapter on each side and end. All buoyant apparatuses have worn/missing retro-reflective tape that needs to be installed/replaced.
46 CFR 160.010-4(p)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: MI witness/verified all life rings are SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2024
Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Both MDE's were missing lagging at the beginning connection point of the exhaust manifold and at all connection bolts. Guards/Lagging are required to prevent crew injuries.
46 CFR 182.20-20
46 CFR 182.15-20(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: MI witness/verified that lagging was installed on both exhaust Manifolds.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Receptacle in the center of the engine room between the MDEs was missing its cover, allowing access to electrical hazards.
46 CFR 183.01-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: Recepticle/cover was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Both MDE's have belt driven pump (bilge pump and fire pump) without guards. Exposing crew to possible injury from rotating machinery. Guards must be provided.
46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2024
Resolved 3 April 2024
Resolution: Guards were added to both MDE belt areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 January 2024
Resolved
Mechanically propelled "S" vessels which are ferry vessels or which carry more than 49 passengers and mechanically propelled "L" vessels shall comply with the provisions of Sub-chapter F of this chapter. Nonmetallic flexible hose may be used in lengths not exceeding 76 cm (30 inches) where flexibility is required. Forepeak bilge connection in the engine room from the bulkhead to a stop valve has a straight nonmetallic flexible hose where flexibility is not required. All other bilge connections in the engine room are metallic. Remove nonmetallic flexible hose and install metallic pipe connection or provide MI with justification for its presence.
46 CFR 182.40-5(b)
46 CFR 56.60-25(b)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 3 April 2024
Resolution: See "Deficiency Documents" for Rep's reasoning, MI satisfied with explanation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2023
Resolved
A propulsion engine control system, including pilothouse control, must be designed so that a loss of power to the control system does not result in an increase in shaft speed or propeller pitch. Submit Qualitative Failure Analysis (QFA) and Design Verification Test Procedures (DVTP) of the vessel's propulsion engine control system for loss of power.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2023
Resolved 25 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
Vessel must submit plans for re-power of both main engines. Once plans are submitted to Marine Safety Center and approved, marine inspector will attend to test approved plans for main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 April 2023
Resolution: Vessel has approved re-power plans from MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2020
Resolved
Propulsion machinery shall be capable of operating at constant marine load without exceeding it's designed limitations. Port side propulsion system is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2021
Resolution: Appropriate repairs were made. Sea trials conducted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2020
Resolved
Propulsion machinery shall be capable of operating at constant marine load without exceeding it's designed limitations. Port and starboard paddle wheels are both missing blades.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 June 2021
Resolution: New paddle wheels were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 October 2019
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Port engine is missing its guard for the fire pump belt.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 21 October 2019
Resolution: Received a photo showing a guard around the firepump belt.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 October 2019
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. In the machinery space, sealant used for each watertight bulkhead penetration (on both bulkheads) is worn, making the penetrations not watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Crew member plugged all penetrations with watertight sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2019
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 02 lifejackets were condemned during inspection and another 02 lifejackets were missing from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Crewmember landed 04 new life jackets on board during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2018
Resolved
An adult life jacket must be provided for each person onboard vessel. 17 life jackets condemned. Vessel restricted to 137 persons. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 November 2018
Resolution: New lifejackets purchased.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: Verified static draft was updated.
Construction/Loadline › Structures › Air Pipe
Issued 17 November 2017
Resolved
Found gooseneck for forepeak wasted through. Provide permanent repair.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2018
Resolution: Repair complete.
Lifesaving › Lifebuoys › Serviceable
Issued 17 November 2017
Resolved
Replace 01 life ring on portside.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 30 November 2017
Resolution: Replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2017
Resolved
Label 01 lifering on stbd side.
Condition: Invalid
Due 24 November 2017
Resolved 30 November 2017
Resolution: Labeled.
Fire Fighting › Fire Main › Condition
Issued 20 October 2016
Resolved
Fire main branch line found with pin hole leak. Replace piping.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Resolution: New fire main branch line installed.
Engineering › Bilge Water Management System › Manifold
Issued 20 October 2016
Resolved
Bilge manifold not labeled. Label each individual bilge line.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 30 November 2016
Resolution: Bilge labled
Construction/Loadline › Penetrations › Gasket
Issued 20 October 2016
Resolved
Gasket on forward hatch worn. Replace gasket.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 15 December 2016
Resolution: New gasket installed.
Construction/Loadline › Structures › Manhole
Issued 20 October 2016
Resolved
Two emergency escape hatches were not labeled. Label each hatch on both sides, 1 inch lettering, "EMERGENCY HATCH, KEEP CLEAR"
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 30 November 2016
Resolution: Labled.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 October 2016
Resolved
Total persons allowed is limited to 152 persons until two life jackets are added.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 10 November 2016
Resolution: Vessel rep. aquired two new life jackets.
Fire Fighting › Fire Pumps › Pressure
Issued 20 October 2016
Resolved
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Vessel rep. proved proper operation of vessels fire pump.