Records from 1996 to 2025. Most recent: inspection, 17 November 2025.
Inspection history · 46
17 November 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8256593
12 December 2024
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8045249
2 December 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8041784
9 October 2024
Internal Structural Exam · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8012329
25 April 2024
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7902075
17 January 2024
Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7847697
7 April 2023
Construction Oversight · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7692664
19 December 2022
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7610976
18 November 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7349723
7 October 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7073926
9 July 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7001437
17 October 2019
Administrative Inspection · Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6836288
29 November 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589699
7 December 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6319990
29 November 2017
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6314914
16 November 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6307939
19 October 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6025370
5 November 2015
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5758542
26 October 2015
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5750919
20 October 2015
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5746552
22 October 2014
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5009822
9 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4204917
2 November 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3883274
15 October 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3345228
19 November 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3100917
31 October 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3090941
3 November 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2527423
12 October 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2512607
12 November 2004
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2233895
3 November 2004
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2233827
1 March 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2015445
6 August 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1868323
2 July 2003
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1833773
20 May 2002
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1618437
21 May 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1406938
1 June 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 819016
2 May 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1432319
18 January 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1455807
10 May 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 794982
30 April 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 794983
1 May 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126565
20 January 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 776215
9 June 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 776629
12 May 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1105103
14 April 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1095271
2 May 1996
Deadweight Survey · Initial Construction-Excluding Oversight · Plan Review "T" Boat · MARPOL Annex V Examination · MARPOL Annex I Examination · Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1081275
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 October 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring grab line was deteriorated and a section was not secured to ring buoy. Also the bulb on the waterlight affixed to the life ring was broken and not serviceable. Vessel is restricted to daytime operations until waterlight is replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 30 October 2024
Resolution: O/O replaced lifebuoy and waterlight to satisfaction of attending marine inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 October 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2024
Resolved 30 October 2024
Resolution: O/O updated DAPI program to include training and education. EAP hotline number is now also posted in main office where all employees frequent.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2024
Resolved
Covered metal trash containers shall be provided in lounge areas. The waste receptacles found on the vessel at the time of inspection were made of a non-metal combustible material.
46 CFR 177.30-7 (d)
(Existing Vessel)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 30 October 2024
Resolution: O/O installed metal trashcan on vessel and removed old combustible one.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 January 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10.
46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
Resolution: Rectified on the spot, see "Deficiencies Documents".
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 January 2024
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. The cable run compartment #4 (Engine Room) to compartment #3 (Black Water Void) allows the atmosphere between the two spaces to be share. A seal/ fire stop must be installed.
46 CFR 177.405(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 6 February 2024
Resolution: Received photos from Rep showing fire stop for cables from on compartment to another, see "Deficiencies Documents".
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 January 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge. Audible alarm did not sound, needs to be repaired or replaced.
46 CFR 182.530(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 6 February 2024
Resolution: Received a video showing the audible and visual bilge alarm for the E/R, unable to save video in "Deficiencies Documents".
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 December 2022
Resolved
A hatch cover must have securing devices. Hatch on aft storage void was missing quick action closing arm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2023
Resolved 12 January 2023
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 17 October 2019
Resolved
The discharge end of vent pipes shall be fitted with removable flame screens or flame arrestors. The screen shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. No flame screens present on the port and stbd f/o tank vents. Provide required flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 23 October 2019
Resolution: Flame arrestor mesh installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 October 2019
Resolved
Penetrations of required watertight decks and bulkheads by any rigid plastic pipe systems are prohibited, except when
each such penetration is accomplished using an acceptable metallic fitting, welded or otherwise attached to the bulkhead or deck by an accepted method; and
an acceptable metallic shutoff valve is installed adjacent to the through deck or through bulkhead fitting. PVC penetration found through a MWTB that did not have a shutoff valve installed. Install a metallic shutoff valve as required on both sides of the bulkhead attached directy to the metal fitting on the bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 13 November 2019
Resolution: PVC piping replaced with aluminum piping. Positive shutoff valve installed in the forward compartment.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 29 November 2018
Resolved
Onboard VHF radio not transmitting, not to operate beyond 1000 feet from shore until VHF radio repaired/replaced iaw 47CFR80.905.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2018
Resolved 12 December 2018
Resolution: Installed new radio. Verified installation and conducted satisfactory radio check.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 November 2018
Resolved
Post at operating station emergency procedures.
Action required: 10 - Deficiency Rectified
Due 29 December 2018
Resolved 29 November 2018
Resolution: Emergency procedures posted at operating station.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 November 2018
Resolved
Provide proof of EAP training for Drug Program DER iaw 46CFR16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2018
Resolved 27 December 2018
Resolution: Received proof of EAP training conducted on 12/18/2018.
Fire Fighting › Fire Main › Material
Issued 16 November 2017
Resolved
Renew fire main in compartment aft of engine room where temp. repair was made using flex hose. (To be corrected during next DDX/prior to hull credit)
Action required: 705 - Other - as specified
Resolved 7 December 2017
Resolution: Verified temp repairs made to fire main were made permentent via hard piping.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 October 2015
Resolved
Label and separate child life jackets from adult life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2015
Resolved 20 November 2015
Resolution: Seperated lifjeackets and labeled them in storage box.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 October 2015
Resolved
Renew retro relfective tape on life ring.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2015
Resolved 20 November 2015
Resolution: Placed retro tape on life ring.
Fire Fighting › Structural - B Class Divisions › Windows
Issued 22 October 2014
Resolved
Replace broken window on stern centerline
Due 5 November 2014
Resolved 20 November 2014
Resolution: Broken window has been replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 22 October 2014
Resolved
Provide current charts, light list, and coast pilot.
Due 5 November 2014
Resolved 23 October 2014
Resolution: Vessel rep provided new charts, light list, and coast pilot.
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 79 PERSONS(PASSENGERS AND CREW) 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 17 April 2012
Resolution: MSC issued updated stability letter.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 12 November 2004
Resolved
Properly splice anchor rope onto anchor.
Condition: Improper/Lack of Maintenance
Due 12 December 2004
Resolved 12 December 2004
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 12 November 2004
Resolved
Post valid FCC.
Condition: Unknown
Due 12 December 2004
Resolved 12 December 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 November 2004
Resolved
Prior to operating next season (2005) conduct an underway man overboard and fire drill with vessel's crew in the presence of a marine inspector.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 31 March 2005
Resolution: Cleared
Construction/Loadline › Hull
Issued 1 March 2004
Resolved
Properly Repair pitting on outer shell IWO both Rudder post and wear areas above both props. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 13 April 2004
Resolution: Installed insert of 3/8 inch 5086 aluminum IWO both props/rudder post. Test Sat.
Documentation › Certificates/Documents
Issued 20 May 2002
Resolved
Provide current Radiotelephony Certificate.
Due 3 June 2002
Resolved 5 September 2003
Resolution: Received fax copy of new certificate.
Construction/Loadline › Hull
Issued 20 May 2002
Resolved
Conduct credit drydock examination.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2002
Resolution: Exam completed; credit given.
Electrical
Issued 21 May 2001
Resolved
PROPERLY MOUNT BATTERY BOX BY GENERATOR IN ENGINE ROOM.
Condition: Unknown
Due 28 May 2001
Resolved 20 May 2002
Electrical
Issued 21 May 2001
Resolved
REPLACE ALL TWIST-TYPE WIRE CONNECTORS WITH PROPER CONNECTORS IN BILGE ALARM SYSTEM, FRESH WATER PUMP, AND SALTWATER PUMPS.
Condition: Unknown
Due 28 May 2001
Resolved 20 May 2002
Engineering
Issued 21 May 2001
Resolved
PROVE PROPER OPERATION OF PORT ENGINE RPM GAUGE IN PILOTHOUSE.
Condition: Unknown
Due 28 May 2001
Resolved 20 May 2002
Lifesaving
Issued 2 May 2000
Resolved
Generator starting battery box missing, battery not secured. Provide battery box and properly secure the battery.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Navigation
Issued 30 April 1999
Resolved
POST A DURABLE PLACARD NEXT TO ALL RADIO TELEPHONE INSTALLATIONS WITH THE EMERGENCY BROADCAST INSTRUCTION AND INFORMATION SPECIFIC TO THE INDIVIDUAL VESSEL IN ACCORDANCE WITH 46CFR 184.510.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Electrical
Issued 30 April 1999
Resolved
GENERATOR, 8KW ONAN DESIGNED TO ALLOW WATER TO PASS OVER THE GENERATOR. RELOCATE LINES AND REPAIR LEAK.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 30 April 1999
Resolved
PROVIDE AND TEST BILGE ALARMS FOR EACH SPACE WITH A THROUGH HULL FITTING BELOW THE WATERLINE.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Navigation
Issued 30 April 1999
Resolved
MODIFY THE STABOARD STEERING CONNECTION TO THE TILLER ARM TO ALLOW JOINT TOOPERATE WITHOUT CHAFING AWAY THE FITTING. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 1 May 1998
Resolved
Conduct emergency drills and properly log or otherwise document crew training, including date of training, and general discription of the training topics.
Condition: Unknown
Due 7 June 1998
Resolved 27 May 1998
Fire Fighting
Issued 1 May 1998
Resolved
Hand portable fire/bilge pump missing. Provide onboared required hand fire/bilge pump.
Condition: Unknown
Due 7 June 1998
Resolved 27 May 1998
Lifesaving
Issued 12 May 1997
Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Documentation
Issued 12 May 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE CHEMICAL TESTING REGULATIONS CONTAINEDIN 46 CFR PART 16.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Construction/Loadline
Issued 14 April 1997
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS BUT NOT LATER THAN 02MAY97, MAKE VESSELAVAILABLE FOR AN INTERNAL EXAM IN WAY OF NEW INSERTS IN E/R AND AFT VOID SPACE.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997