Records from 1987 to 2025. Most recent: inspection, 22 September 2025.
Inspection history · 62
22 September 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8244459
10 June 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8151877
27 March 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7885789
28 February 2023
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7643329
3 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7404683
22 June 2021
Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7232896
10 March 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7153776
16 October 2020
Examination of Repairs · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7078673
5 February 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6903320
27 February 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6633713
25 January 2018
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6339960
2 January 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6331581
16 February 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6089374
17 June 2016
Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5910034
8 March 2016
Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5910029
10 March 2014
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4820425
14 December 2011
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4208271
2 December 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4200204
10 February 2011
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3945502
5 May 2009
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3474812
8 January 2009
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3390349
13 November 2007
COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3095827
3 November 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2535819
26 October 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2246121
9 December 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1961231
18 July 2003
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1850262
12 November 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1704422
30 October 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1698484
15 January 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1478862
15 November 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 772316
18 November 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 810684
28 October 1999
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1129572
9 November 1998
Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 805120
14 November 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1110028
27 November 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1183847
19 November 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862394
20 May 1996
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1085302
20 May 1996
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1085960
13 November 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 875798
12 September 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 883119
9 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1148160
22 November 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1178455
18 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 181150
17 December 1993
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 849342
29 November 1993
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1158049
29 November 1993
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1158694
10 November 1993
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 844089
26 June 1993
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1155024
11 January 1993
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1139780
16 December 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142091
12 November 1992
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 962668
9 January 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 953509
11 January 1991
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917548
13 December 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227336
17 November 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 909965
17 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917567
10 July 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1351095
21 June 1989
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1351094
16 February 1989
Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037775
30 November 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1211965
14 November 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1206596
18 November 1987
Hull Examination · Initial Certification
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1314238
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 September 2025
No resolution recorded
Primary consideration shall be given to the provision of a seaworthy hull. Port side transverse frame forward of the E/R bulkhead located in void was wasted in the horizontal and vertical portions. Submit repair proposal.
46 CFR 177.01-5 / 60c
Action required: 60 - Rectify deficiencies prior to movement
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 June 2025
No resolution recorded
Primary consideration shall be given to the provision of a seaworthy hull. Port side transverse frame forward of E/R bulkhead located in void was wasted in the horizontal and vertical portions. Submit repair proposal.
46 CFR 177.01-5
(Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 June 2025
No resolution recorded
Primary consideration shall be given to the provision of a seaworthy hull. Vessel had numerous holes through port side bulkhead above the weld at the walkway. Submit
repair proposal prior to next credit dry dock.
46 CFR 177.01-5
(Old T)
Action required: 60 - Rectify deficiencies prior to movement
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2025
Resolved
A main transverse watertight bulkhead must not be penetrated by valves unless they are a part of a piping system. Vessel had three penetrations through the lazarette into the E/R fitted with gate valves that are not part of a piping system.
46 CFR 171.111(d)
(Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2025
Resolution: Piping was plugged.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2025
Resolved
Battery connections shall be made to the battery terminals with permanent type connectors. Battery
terminals were connected with wing nuts.
46 CFR 183.05-20(c)
(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 30 July 2025
Resolution: Replaced with nuts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2025
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire and shock of personnel caused from electrical equipment. Both engine block heaters were daisy chained. Connect using permanent outlet.
46 CFR 183.01-5
(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 30 July 2025
Resolution: Daisy chain was disconnected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2025
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements. Starboard propulsion engine lube oil transfer hose is chaffed.
46 CFR 182.05-1
(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 30 July 2025
Resolution: Lube oil hoses were replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 June 2025
No resolution recorded
The intent of this part is to ensure that the scantlings, material, fastenings,workmanship and arrangement of each vessel as such to provide for safe operation. Vessel had hole in engine room ceiling located above port side fuel tank. Submit repair proposal prior to credit dry dock.
46 CFR 177.01-5
(Old T)
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 June 2025
Resolved
The marine employer must have sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel did not have any alcohol testing devices on board.
46 CFR 4.06-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 30 July 2025
Resolution: Alcohol test strips were on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 June 2025
Resolved
The intent of this part is to ensure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation. Tail shaft packing on both tail shafts were leaking water excessively.
46 CFR 182.05-1
(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 30 July 2025
Resolution: Shaft seals were tightened and no longer leaking excessively.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2023
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Vessel's Certificate of Inspection expired 25JAN2023.
Vessel must complete Certificate Of Inspection examination prior to carrying passengers/cargo. 46 CFR 176.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2023
Resolved
All cable and wire must: be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Observed electrical wiring for the bilge stripping pump in the machinery space was secured with zip ties. Install metal supports along electrical wiring at intervals of not more than 24 inches apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 10 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2023
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Observed guard around exterior PORT side wheelhouse light was missing. Provide new light guard around light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 10 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 February 2023
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Observed vessel name on the life ring was peeling off. Provide new markings with vessel name on life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 10 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2023
Resolved
Placards containing instructions for the donning and use
of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Observed no placard containing donning and use of the life jackets was present on the vessel. Post a placard on board with donning instructions appropriate for the type of life jacket found on board.
Due 15 April 2023
Resolved 11 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 March 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 once every five years. Vsl did not have a valid Communications Act Safety Radiotelephone Certificate. Prove to the USCG that vsl has a valid Communications Act Safety Radiotelephone Certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 11 March 2022
Resolution: FCC Safety Radio provided to the satisfaction on attendidng MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 March 2022
Resolved
...inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Starboard windowpane at the operating station is cracked. Replace starboard window pane.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 29 March 2022
Resolution: Windowplane replaced to the satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2022
Resolved
A vessel must carry one floating waterlight...Battery on the ring life buoy expired in 2019. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 21 March 2022
Resolution: New, approved, battery was installed to the satisfaction of attending MI.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 March 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 46 CFR 160.041 or a kit with equivalent contents and instructions. Vsl did not have a fully stocked first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 10 March 2022
Resolution: New, approved, frist aid kit was provided to the satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2022
Resolved
Each...ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy did not have complete vsl name. Ensure full name of vsl is on ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 10 March 2022
Resolution: Marked properly to the satisfaction of attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 March 2022
Resolved
Each hatch exposed to the weather must be watertight... The gaskets on multiple hatches on the cargo deck were not complete. Replace gaskets to make watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 17 March 2022
Resolution: Hatches sealed to the satisfaction of attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 March 2022
Resolved
...inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. On the port and starboard side of the engine room above the dry exhaust, there were black stains on the side shells. Clean black stains to ensure that installed dry exhaust system is not leaking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 17 March 2022
Resolution: Area cleaned to the satisfaction of attending MI.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 3 March 2022
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities.
Vsl's radio at the operating station does not display the ship's MMSI number. Install a radio that displays
the ship's MMSI number.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 10 March 2022
Resolution: VHF displaying proper MMSI and able to broadcast Lat and Long to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 June 2021
Resolved
The hull shall be in a satisfactory condition for the service intended. Hull bottom thru hull area between the shafts is significantly corroded and Requires repair. Submit Gage report & Repair Proposal plan.
Action required: 705 - Other - as specified
Resolved 28 July 2021
Resolution: Attended vessel for final weld inspection after plate crop and renew, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 June 2021
Resolved
The hull shall be in a satisfactory condition for the service intended. Grind out port amidship identified area and submit Gage Report and Repair Proposal Plan.
Action required: 705 - Other - as specified
Resolved 28 July 2021
Resolution: Attended vessel for final weld inspection after plate crop and renew, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2021
Resolved
Port side hand rail to bulwarks weld was cracked and allowing water to enter the port void space. Repair port side aft handrail to bulwark welds.
Action required: 705 - Other - as specified
Resolved 16 August 2021
Resolution: photos sent in
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 10 March 2021
Resolved
A hatch exposed to the weather must be watertight. The gasket for the hatch access to the lazarette is damaged. Replace the gasket to make watertight.
CITE: 46 CFR §179.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2021
Resolved 22 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2021
Resolved
Flexible hose must meet the requirements of §182.720(e). The flexible fuel hose connecting the fill pipe to both fuel tanks are severely degraded, with numerous cracks. Replace all damaged flexible fuel hose in way of the fuel tanks.
CITE: 46 CFR §182.445
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2021
Resolved 22 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q. The battery for the waterlight was expired. Replace the battery for identified waterlight.
CITE: 46 CFR §180.70
Action required: 10 - Deficiency Rectified
Due 24 March 2021
Resolved 10 March 2021
Resolution: Replaced before the end of the inspection.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 October 2020
Resolved
Prior to carrying passengers or cargo, provide and make repairs to identified areas of cargo deck as discussed in person on 16OCT2020. 46 CFR 176.700
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2020
Resolution: Completed satisfactory repairs and NDT on affected cargo deck area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 February 2020
Resolved
Make proper repair to vessel's bilge pump. Test in presence of USCG MI.
Action required: 10 - Deficiency Rectified
Due 5 February 2020
Resolved 5 February 2020
Resolution: Vessel replaced impellor and successfully tested bilge pump.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 February 2020
Resolved
Renew FCC Safety Radio Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 27 February 2020
Resolution: Vessel received a new FCC Safety Radio Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 February 2020
Resolved
Install strainer on bilge line in 4th void space from aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 27 February 2020
Resolution: Vessel installed a new bilge strainer.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2018
Resolved
AM01: Install machinery guard over belt connecting starboard engine and bilge pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 4 March 2018
Resolution: Attended vessel: observed satisfactory guard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 January 2018
Resolved
Vessel failed to complete a 5 year COI inspection within the required timeframe. COI is no longer valid IAW 46 CFR 176.107(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2018
Resolution: Completed COI inspection.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 February 2017
Resolved
Submit repair proposal for deck beam in #1 compartment centerline. 02MAR17
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 2 May 2017
Resolution: Completed necessary repairs on forward compartment deck beam.
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2016
Resolved
LK01 All charts must be up to date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 21 March 2016
Resolution: Up to date charts were placed on board vessel. Deficiency cleared.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 March 2016
Resolved
LK02 Vessel's emergency instructions must reflect crew's actions and equipment.
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 21 March 2016
Resolution: Emergency instructions now accurately reflect vessel and crew actions. Deficiency cleared.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 March 2014
Resolved
Provide proof of FCC Safety Radio Certificate. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 13 March 2014
Resolution: [name withheld] emailed picture of FCC Safety Radio Certificate.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 March 2014
Resolved
Replace retroflective tape on life jackets (4) with approved tape.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2014
Resolution: [name withheld] emailed picture of new approved tape on life jackets.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 March 2014
Resolved
On the ring buoy replace the grab line, ensure light lanyard is 3 - 6 ft, add 2 pieces of retro reflective tape. 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2014
Resolution: [name withheld] emailed picture of new ring buoy, grab line, light lanyard, and sufficient tape.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 March 2014
Resolved
Ensure battery caps are replaced. Cable is exposed at battery terminals repair as original.
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 13 March 2014
Resolution: [name withheld] emailed picture of battery caps and tape on the exposed battery terminals.
Engineering › Steering Gear System › Bracket/Clamp
Issued 10 February 2011
Resolved
Steering box bracket holes elongated where bolts go through causing excessive play. - 21 days
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 14 March 2011
Resolution: Verified new bracket installed- no more play in steering
Engineering › Bilge Water Management System › Strainer
Issued 10 February 2011
Resolved
Install suitable strainer to engine room bilge suction. -14 days
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 14 March 2011
Resolution: Verified strainer installed.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 10 February 2011
Resolved
Remove "caked" oil from aft stbd bilge area- 14 days
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 14 March 2011
Resolution: Verified oil removed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 February 2011
Resolved
Lazarette hatch wasted around seal and gasket is not sealing- 21 days
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 14 March 2011
Resolution: Repairs made to hatch.
Construction/Loadline › Hull › Transverse Frame
Issued 10 February 2011
Resolved
Transverse frames, longitudinal stiffeners, and upper transverse stiffeners wasted in lazarette.- call w/repair plan/date - 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2011
Resolved 27 April 2011
Resolution: Vessel undergoing repairs. Started activity new activity dated 27 April 2011, to document repairs.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 8 January 2009
Resolved
Install fire bowl on Racor fuel filter.
Due 8 February 2009
Resolved 28 January 2009
Resolution: New Racor filter with fire bowl installed.
Lifesaving › Hand Flares › Expired
Issued 8 January 2009
Resolved
Provide three handheld orange hand flares.
Action required: 705 - Other - as specified
Resolved 8 January 2009
Resolution: Corrected during inspection with new orange hand flares.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 December 2003
Resolved
Service all portable fire extinquishers prior to 12 December 2003.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 11 December 2003
Resolution: Operator faxed copy of service receipt to this office.
Navigation › Collision/Grounding Avoidance
Issued 12 November 2002
Resolved
RENEW 02 CRACKED WINDOWS IN PILOT HOUSE. LEGACY COMPONENT DESC: Navigation Bridge Visibility
Condition: Damaged By Earlier Event
Due 14 December 2002
Resolved 2 December 2002
Resolution: RENEWED BROKEN GLASS IN PILOT HOUSE.
Construction/Loadline › Structures
Issued 30 October 2002
Resolved
SEAL WIRE PENETRATION IN FWD LAZZARETTE BULKHEAD. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 30 November 2002
Resolved 13 November 2002
Engineering › Sea-water System (primary cooling)
Issued 30 October 2002
Resolved
CLEAN/DRESS VALVE SEAT AREA OF PORT MDE SEA SUCTION VALVE AND VALVE DISK ON FIRE MAIN VALVE. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 13 November 2002
Engineering › Steering Gear System
Issued 30 October 2002
Resolved
PROVE PROPER OPERATION OF STEERING SYSTEM FOLLOWING REPLACEMENT IN KIND OF BOTH RUDDERS, RUDDER SHAFTS, PACKING GLANDS, STEERING LINKAGE AS PER SUBMITTED PLANS. LEGACY COMPONENT DESC: Rudder
Due 30 November 2002
Resolved 13 November 2002
Engineering › Shafting/Propeller Arrangements
Issued 30 October 2002
Resolved
RENEW PORT AND STARBOARD PROPELLER SHAFT STRUT BEARINGS. LEGACY COMPONENT DESC: Strut Bearing
Due 30 November 2002
Resolved 13 November 2002
Engineering › Steering Gear System
Issued 30 October 2002
Resolved
SUBMIT PROPOSAL PLAN TO SECURE RUDDER POSTS FROM VERTICAL MOVEMENT. LEGACY COMPONENT DESC: Rudder Stock
Due 30 November 2002
Resolved 13 November 2002
Navigation
Issued 15 November 2001
Resolved
PROCURE COAST PILOT AND C.G. LIGHT LIST PUBLICATIONS.
Condition: Unknown
Due 15 December 2001
Resolved 15 January 2002
Resolution: INSPECTED SAT.
Lifesaving
Issued 15 November 2001
Resolved
RENEW RETRO-REFLECTING TAPE ON LIFE RING.
Condition: Unknown
Due 15 December 2001
Resolved 15 January 2002
Resolution: INSPECTED SAT.
Lifesaving
Issued 15 November 2001
Resolved
REPLACE ASPIRIN AND RENEW EYE WASH SOLUTION IN FIRST AID KIT.
Condition: Unknown
Due 15 December 2001
Resolved 15 January 2002
Resolution: INSPECTED SAT.
Construction/Loadline
Issued 9 November 1998
Resolved
THE WELD JOINING THE 2X8 PLATE, AS NOTED IN INDENT 004, TO THE SIDE SHELL IS PITTED DUE TO ELECTROLYSIS.
Condition: Unknown
Due 9 December 1998
Resolved 17 November 1998
Accommodation/Occupational Safety
Issued 9 November 1998
Resolved
WELDS FOR TWO VERTICAL RAILINGS, LOCATED ALONG THE AFT DECK, SEPARATED FROMTHE DECK.
Condition: Unknown
Due 9 December 1998
Resolved 30 November 1998
Construction/Loadline
Issued 9 November 1998
Resolved
SIDE PLATING, STARBOARD AFT, AT THE CORNER POST, A 5" HAIRLINE FRACTURE WAS DISCOVERED IN THE WELD.
Condition: Unknown
Due 9 December 1998
Resolved 30 November 1998
Construction/Loadline
Issued 9 November 1998
Resolved
BOTTOM PLATING SHOWED EVIDENCE OF ELECTROLYSIS LOCATED ON A 2X8 PLATE, WHICH WAS REPLACED NEW 19NOV96, THE PLATE IS LOCATED AT THE NUMBER 2 PORT VOID TANK. THE WASTAGE MAY BE DUE TO POOR SURFACE PREP AND COATING APPLICATION WHEN THE PLATE WAS REPLACE 19NOV96.
Condition: Unknown
Due 9 December 1998
Resolved 17 November 1998
Navigation
Issued 9 November 1998
Resolved
BOTH RUDDER ATTACHMENTS AT THE BOTTOM OF THE RUDDERS WERE LOOSE DUE TO MISSING NUTS.
Condition: Unknown
Due 9 December 1998
Resolved 17 November 1998
Construction/Loadline
Issued 13 November 1995
Resolved
MAKE ALL VOIDS WITH EXCEPTION OF 2P, 3C, 4S ACCESSIBLE FOR INSPECTION.
Condition: Unknown
Due 13 December 1995
Resolved 27 November 1995
Electrical
Issued 29 November 1993
Resolved
PROVIDE WEATHER-TIGHT COVER FOR OUTSIDE RECEPTACLE USED IN HEATING ENGINES (IN WAY OF DECK HOUSE ON FORWARD PORT SIDE).
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Documentation
Issued 29 November 1993
Resolved
PROVIDE PROOF OF A SATISFACTORY FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Accommodation/Occupational Safety
Issued 10 November 1993
Resolved
MAKE PERMANENT REPAIRS TO STBD SIDE GUARD RAIL WHERE BROKEN LOOSE FROM DECKMOUNTINGS ALONG THE SIDE OF THE PILOTHOUSE.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Construction/Loadline
Issued 10 November 1993
Resolved
MAKE PERMANENT REPAIRS TO THE 1/8" HOLE IN THE DECK OUTBOARD OF THE PILOTHOUSE.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Navigation
Issued 10 November 1993
Resolved
PRIOR TO CARRYING CARGO AND PRIOR TO RECEIVING A CREDITED DRYDOCK MAKE PERMANENT REPAIRS TO STBD RUDDER POST TO ELIMINATE EXCESSIVE PLAY.
Condition: Unknown
Due 15 November 1993
Resolved 15 November 1993
Engineering
Issued 10 November 1993
Resolved
PRIOR TO CARRYING CARGO AND PRIOR TO RECEIVING CREDITED DRYDOCK EXAMINATIONREPLACE OR RENEW STBD SCREW DUE TO 1" CRACK FOUND IN ONE OF THREE BLADES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 November 1993
Resolved 15 November 1993
Construction/Loadline
Issued 16 December 1992
Resolved
REMOVE OIL FROM BILGE IN WAY OF ENGINE ROOM SPACE.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Navigation
Issued 17 November 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Lifesaving
Issued 17 November 1989
Resolved
VESSEL HAD FIVE SMOKE DISTRESS SIGNALS THAT WERE OUTDATED.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Navigation
Issued 17 November 1989
Resolved
VESSEL DID NOT HAVE ANY CHARTS ON BOARD
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Navigation
Issued 17 November 1989
Resolved
VESSEL DID NOT HAVE ON BOARD DEVIATION TABLE AS REQUIRED FROM FIRST REINSPECTION ON 14NOV88.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Construction/Loadline
Issued 21 June 1989
Resolved
REPLACE APPROXIMATELY 3' X 5' OF 1/8" DECK PLATE OVER #4 VOID SPACE. ORIGINAL COMPLIANCE DATE IS 30JUN89.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Engineering
Issued 21 June 1989
Resolved
REPLACE APPROXIMATELY 5 FEET OF 1 1/4' BILGE PIPING (2 PIPES) REMOVED FROM #4 WATERTIGHT VOID SPACE. ORIGINAL COMPLIANCE DATE IS 30JUN89.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Construction/Loadline
Issued 21 June 1989
Resolved
REPLACE APPROXIMATELY 5 FEET OF 6" X 2" X 1/8" I BEAM AND 5 FEET OF 3/8" FLATBAR REMOVED FROM #4 VOID SPACE. ORIGINAL COMPLIANCE DATE IS 30JUN89.
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Navigation
Issued 14 November 1988
Resolved
PROVIDE A CURRENT COAST PILOT.
Condition: Unknown
Due 14 November 1988
Resolved 14 November 1988
Electrical
Issued 14 November 1988
Resolved
CLOSE IN TOP TO ELECTRICAL PANEL ON BRIDGE STARBOARD SIDE.
Condition: Unknown
Due 14 November 1988
Resolved 14 November 1988
Navigation
Issued 14 November 1988
Resolved
PROVIDE A DEVIATION TABLE FOR THE MAGNETIC COMPASS.
Condition: Unknown
Due 14 November 1988
Resolved 14 November 1988
Navigation
Issued 14 November 1988
Resolved
ADJUST TENSION ON STEERING CHAIN IN ENGINEROOM.
Condition: Unknown
Due 14 November 1988
Resolved 14 November 1988
Construction/Loadline
Issued 14 November 1988
Resolved
PROVIDE AND INSTALL WINGNUTS TO SECURE STERN HATCH TO STEERING COMPARTMENT.(AFTER RAKE).
Condition: Unknown
Due 14 November 1988
Resolved 14 November 1988
Fire Fighting
Issued 14 November 1988
Resolved
RECHARGE OR REPLACE ONE B-I FIRE EXTINGUISHER FOR THE PILOT HOUSE.
Condition: Unknown
Due 14 November 1988
Resolved 14 November 1988