Records from 2002 to 2025. Most recent: operational control imposed, 26 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 36
25 November 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8271651
24 June 2025
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8165756
9 May 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8131900
14 April 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118110
3 January 2025
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8057078
19 November 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8037287
15 July 2024
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7959941
1 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7943674
16 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7937295
11 June 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933290
4 January 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7845697
21 August 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7773296
18 July 2023
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7733789
2 December 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7603431
18 November 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7596765
12 January 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7379659
28 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7373167
23 February 2021
Plan Review (Other than "T") · Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7144808
9 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7138144
5 February 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7140040
22 October 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7082675
17 June 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7055640
10 April 2020
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6941916
18 March 2020
Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6930336
3 January 2020
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6882444
24 December 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6884619
30 October 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6845453
26 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548897
21 September 2018
Internal Structural Exam · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6545780
15 February 2018
Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6355532
4 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6318109
14 November 2017
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6306535
21 February 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6092294
28 June 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5922691
16 May 2016
Plan Review (Other than "T") · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5878754
19 February 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5817168
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 November 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. During Annual inspection, MI’s identified that (03) Main Engines were not operating as designed:
Port Forward Main: Unable to reach sufficient RPMs
Port Aft Main: Consistent high oil temp alarm
Starboard Forward Main: Engine secured at low RPMs, unable to re-start.
Troubleshoot engines and provide technical report with root cause and satisfactory sea trial. Vessel is authorized one-time transit to Larkspur with tug escort.
46 CFR 119.200(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2025
Resolution: Received satisfactory tech report.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 November 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. Jet Drives lacked sufficient guards around the shaft.
46 CFR 116.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2025
Resolved 15 January 2026
Resolution: Received satisfactory photos of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 25 November 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil..or other matter that might create a fire hazard. MI’s identified excessive oil in the starboard main engine room near the forward main engine.
46 CFR 115.830
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 17 January 2026
Resolution: Received satisfactory photos of cleaned bilges.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 November 2025
Resolved
After loading and prior to departure, and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's...stability letter... #2 void Junction Box Wire bulkhead penetration not watertight.
46 CFR 122.315(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 15 January 2026
Resolution: Received satisfactory photo of corrected wire packing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Fuel runoff tank was missing cap.
46 CFR 115.830
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 8 December 2025
Resolution: Received satisfactory photos from operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were identified in the starboard engine room, and aft of the exterior entrance to the starboard main engine room on the main deck.
46 CFR 120.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 8 December 2025
Resolution: Received satisfactory photos from operator.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 November 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Marine Inspector identified possible cracked weld on the flag post. Grind out and re-assess to the satisfaction of MI.
46 CFR 116.100(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 8 December 2025
Resolution: Received satisfactory photos from operator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2025
Resolved
Each…ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The label on the starboard bridge life ring was faded and illegible.
46 CFR 122.604(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received satisfactory picture from operator.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 November 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station. Portable flashlight on bridge was in-operable.
46 CFR 120.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 8 December 2025
Resolution: Received satisfactory photos from operator.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 January 2025
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. Vessel had fire control plan missing defined fire boundaries and no space categorization for designated fire areas. Procure updated fire control plan identifying these areas to MI satisfaction.
46 CFR 116.530
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2025
Resolution: Operator procured updated fire control plan.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 January 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Vessel had small spot of missing fire stop in the port side aft fuel tank void multi-cable transit. Repair to MI satisfaction.
46 CFR 116.405
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 January 2025
Resolution: Accepted photo of repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 November 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not completed an annual inspection within required timeline. Conduct satisfactory annual inspection prior to the carriage of passengers. 46 CFR 115.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2025
Resolution: Vessel conducted sastisfactory annual exam. Op control cleared, vessel is cleared to carry passengers.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 July 2024
Resolved
Pitted aluminum in way of saltwater drains inboard port and STBD. Submit repair proposal.
Action required: 705 - Other - as specified
Resolved 30 August 2024
Resolution: Port side cropped and renewed, STBD side within tolerance.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 July 2024
Resolved
Crop and renew wasted aluminum found in void #3 along keel.
Action required: 705 - Other - as specified
Resolved 30 August 2024
Resolution: Wasted aluminum croped and renewed. passed vacbox.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 July 2024
Resolved
Crop and renew wasted aluminum found in port void #3 along keel.
Action required: 705 - Other - as specified
Resolved 21 August 2024
Resolution: plate croped and renewed, passed vacbox
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 July 2024
Resolved
Submit gauge report and repair proposal for pitting located port and stbd jet drive room.
Action required: 705 - Other - as specified
Resolved 30 August 2024
Resolution: wasted plate croppeed and renewed, vacbox passed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2023
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control. Instructions not present at remote operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Accepted photo with instructions.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 July 2023
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Emergency light main deck centerline forward of the fire doors was not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Accepted report of correction for e-lights.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 18 July 2023
Resolved
A means of escape that is not readily apparent to a person from both inside and outside the space must be adequately marked in accordance with § 122.606 of this subchapter. All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] emergency escape hatch for engine room was missing required marking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Accepted photo for markings.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2023
Resolved
Doors in A-Class fire control boundaries must meet the following additional requirements: Holdback hooks are not allowed. If installed, a hold back mechanism for a door must allow the door to be released: locally; upon signal from a control space; and upon disruption of the power system. Main deck fire doors leading up to 2nd deck are held back by magnets and did not automatically close during loss of power. Further inspection showed the doors maintain battery power during ship’s power loss and the doors can only be closed by crew either locally or from the bridge. Rectify within 60 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2023
Resolved 15 August 2023
Resolution: Company appealed and received approval for existing arrangement to stay in place.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 July 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Port engine room forward fire damper did not automatically close during testing of fixed fire fighting system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 July 2023
Resolution: Verified operation after repair.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 January 2022
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Fwd life rafts painter line was not secured to the float free link.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 27 January 2022
Resolution: Painter properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2022
Resolved
Shutoff valves must be fitted in the fuel supply lines, one at the tank connection to stop fuel flow. Remote fuel shutoff connection is loose at the valve and easily disconnects upon usage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 27 January 2022
Resolution: Verified repaired shutoff connection.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 January 2022
Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air in the event of a fire. STBD bar/crew exterior fire damper on the main deck failed to close.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 27 January 2022
Resolution: Accepted video of proper operation of damper.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards. A cluster of unknown dead end wire was found centerline underneath the bridge console.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 27 January 2022
Resolution: Verified dead end wires properly connected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 January 2022
Resolved
The following vessel must have onboard a properly installed, operational Coast Guard type approved AIS Class A device: A self propelled vessel that is certificated to carry more than 150 passengers. Vessels AIS was not transmitting as confirmed by VTS.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 27 January 2022
Resolution: Verified AIS properly transmitting.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 December 2021
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel is overdue on its annual inspection. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2022
Resolved 12 January 2022
Resolution: 1) 3rd Expanded Annual inspection on the MENDOCINO has been completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 October 2021
Resolved
EACH VESSEL MUST HAVE A STABILITY LETTER ISSUED BY THE USCG BEFORE THE VESSEL IS PLACED INTO SERVICE.
VESSEL COMPLETED A LIGHTSHIP SURVEY IMMEDIATELY FOLLOWING THE COMPLETION OF THEIR 2021 DRYDOCK PERIOD.
VESSEL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL RECEIPT OF MSC ISSUED STABILITY LETTER IS ON BOARD VESSEL AND POSTED AS REQUIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2022
Resolution: Vessel has valid stability letter posted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 February 2021
Resolved
Grind out and re-weld cracked welds identified on 02 structural frames in-way-of 6" crack on port bow.
Action required: 705 - Other - as specified
Resolved 19 May 2021
Resolution: Cracked welds were rapaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 October 2020
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces. The vessel has 5 emergency lights that are out on the main deck forward of the house. The vessel also has 2 emergency lights out on the upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 17 November 2020
Resolution: Vessel had contractors come on board to make electrical repairs to all emergency lights that were not working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. The vessel is utilizing unauthorized strip outlets/extension cords as a permanent installation for appliances located on the main deck galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 17 November 2020
Resolution: Vessel removed all unauthorized power strips and extension cords from the galley/concessions area.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 October 2020
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and inflates automatically. The weak links on the 2 stern inflatable life rafts are installed improperly.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 22 October 2020
Resolution: Vessel removed weak link and installed it in accordance with manufacturers instructions.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 January 2020
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Side shell plating in the inboard side of the starboard jet room has a 6” hairline fracture approximately 3 feet above the waterline. Vessel’s crew must conduct frequent (hourly) rounds of the starboard jet room to ensure there is no water intrusion during operation. Monitor the space and notify the U.S. Coast Guard if the condition changes. Vessel must submit repair proposal plan to U.S. Coast Guard within 2 days.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 January 2020
Resolved 9 January 2020
Resolution: Vessel rep sent MI a repair proposal, which was approved. MI attended the vessel and inspected the weld upon completion of repair. Vessel rep sent MI report with hose test with satisfactory results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2019
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the normally unmanned spaces: a machinery space bilge, bilge well, shaft alley, or other space subject to flooding from sea water piping within the space. Bilge high level alarm was inoperable in the port fuel space (void 4) during inspection.
46 CFR 119.530 (a)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2019
Resolved 5 November 2019
Resolution: Vessel rep [name withheld], sent MI a video of a satisfactory audible and visual bilge alarm for void #4.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or operator shall be prepared to conduct tests and have the veseel ready for inspections of of machinery, fuel, and piping systems, including the following: operational test of the means provided for pumping bilges. Vessel did not demonstrate satisfactory operation of port bilge pump during inspection.
46 CFR 115.804 (h)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2019
Resolved 5 November 2019
Resolution: Vessel rep [name withheld], sent MI videos of the port bilge pump in operation and associated gauges during the test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2019
Resolved
Repairs or alterations to the hull machinery or equipment that affect the safety of vessel must not be made without the approval of the cognizant OCMI, except in an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alterations are made. An unapproved patch was identified on the bilge cross-connected discharge piping during the inspection.
46 CFR 115.804 (h)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2019
Resolved 5 November 2019
Resolution: Vessel rep [name withheld], sent MI a repair proposal and effected permanent repair on the cross-connected discharge piping.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 November 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspections of machinery, fuel, and piping systems. Brackets supporting fire main system are broken between starboard catamaran hull deck and passenger cabin.
46 CFR 115.804
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2019
Resolved 22 November 2019
Resolution: MI verified adequate temporary brackets that will be installed to ensure the firemain is stable until new ones can be installed during vessel's drydock period.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Line is deteriorated on four ring life buoys and lifeline. Two ring life buoys and lifeline were replaced during the inspection. Replace ring life buoy on the bow and on the starboard aft main deck. Deficiency is to be corrected in 7 days.
46 CFR 117.70 (b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2019
Resolved 22 November 2019
Resolution: MI verified life buoy on the bow and on the starboard aft main deck were repaired/replaced respectively.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 30 October 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Iodine wipes and ammonia inhalants were on board were expired at the time of inspection.
46 CFR 121.710
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
IMO: Vsl is broadcasting no IMO #, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 November 2019
Resolution: Verified vessel cleared outstanding AIS errors.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 September 2018
Resolved
Piping used in vital systems must meet 46 CFR 56.60 in sub-chapter F. Non Metallic hose must be SAE J1942. It must be used in lengths not to exceed 30 inches. Non Metallic Hose must be complete with factory assembled fittings requiring no further adjustment of the fittings on the hose. Hose fittings must comply with SAE J1475. Repairs or alterations to machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. #1, #2, #3, and #4 Main Diesel Engine Salt Water cooling systems and Reduction Gear R/W Cooling Systems have non-metallic hoses installed with some installation containing hose clamps and of lengths in excess of 30 inches. Portions of piping at flanges contain dissimilar metal without isolation other portions of piping have been replaced with Viega brand piping and fittings. Portions of entire salt water cooling piping appears to be changed from original and contain many portions that don't appear to meet required vital system piping requirements.
46 CFR 119.710 (c)
46 CFR 56.60-25 (b)(1)
46 CFR 56.60-25 (b)(2)
46 CFR 56.60 (b)(5)
46 CFR 115.700
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 21 January 2021
Resolution: The Issue was briefed to and approved by the [name withheld] piping installations are acceptable under local MMS Policy DOM-05A "Viega Fittings". The nonmetallic hose installations are permissible under local policy for nonmetallic hoses which is pending.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 September 2018
Resolved
Piping used in vital systems must meet 46 CFR 56.60 in sub-chapter F. Non Metallic hose must be SAE J1942. It must be used in lengths not to exceed 30 inches. Non Metallic Hose must be complete with factory assembled fittings requiring no further adjustment of the fittings on the hose. Hose fittings must comply with SAE J1475. Repairs or alterations to machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] S/W Cooling Lines are installed with portions of Viega R/W piping and nonmetallic hoses with hose clamps.46 CFR 119.710 (c)
46 CFR 56.60-25 (b)(1)
46 CFR 56.60-25 (b)(2)
46 CFR 56.60 (b)(5)
46 CFR 115.700
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 21 January 2021
Resolution: The Issue was briefed to and approved by the [name withheld] piping installations are acceptable under local MMS Policy DOM-05A "Viega Fittings". The nonmetallic hose installations are permissible under local policy for nonmetallic hoses has not yet been f
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2018
Resolved
Electrical equipment used Machinery Spaces must be drip proof.
1)Starboard Side 110V outlet near #2 SSDG is exposed.
2)Starboard Side 110V outlet near #4 MDE cover is missing.
3)Port Side 110V outlet missing cover.
46 CFR 120.210
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 20 May 2019
Resolution: Starboard Side 110V outlet near #2 SSDG properly installed.Starboard Side 110V outlet near #4 MDE cover replaced and Port Side 110V outlet cover replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2018
Resolved
A distribution line in a fixed gas fire extinguishing system must extend 2 inches past the last orifice and be closed with a cap or plug. None of the Nozzles in the Port and Starboard hulls for the fixed gas extinguishing systems have the two inch extended section with cap.46 CFR 118.410 (d)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 31 October 2018
Resolution: Global Fire Installed 2 inches of pipe extending past each nozzle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 September 2018
Resolved
Each Power Bilge Pump must have a minimum capacity of 25 gallons per minute. Starboard Side #4 Void bilge pump not adequately pumping bilge.46 CFR 119.520
46 CFR 56.50-55 (c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 10 October 2018
Resolution: Check valve was stuck preventing proper pumping. Repaired check valve and proved proper operation.
Construction/Loadline › Structures › Door
Issued 14 November 2017
Resolved
Doors to port and starboard entrances to engine rooms failed to close properly and require repair or replacement. - 46 CFR 116.405(g)
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 4 December 2017
Resolution: Operator provided photographic evidence of corrected deficiency.
Construction/Loadline › Structures › Deck Plating
Issued 14 November 2017
Resolved
02 holes were found on port and starboard sides of Second Deck, adjacent to ring buoys, which require repairs at next dry-dock period. - 46 CFR 116.100
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 February 2018