WENDY LOU

WENDY LOU is a 1987 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in September 2025, along with 53 deficiencies and 1 casualty investigation in 2002.

Records from 2002 to 2025. Most recent: inspection, 23 September 2025.

Built
1987
Last inspected
23 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 September 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN6970
297165
Flag
UNITED STATES
Maury page id
psix-297165

Documentation record

Registered dimensions (L × B × D)112.2 ft × 23.1 ft × 7.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1987
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
93 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

23 September 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8218236
21 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8215184
9 July 2024 Examination of Repairs · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7937503
18 July 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7745688
16 September 2022 Drydock Exam · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7560370
19 November 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7354468
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108364
23 November 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7099323
21 August 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7039090
9 July 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7025625
2 December 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6867163
30 November 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6595348
22 August 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6519661
2 February 2018 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6349256
25 August 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6251101
28 November 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6048775
10 August 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5968591

Deficiency record · 53

05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 24 September 2025 Resolved
47 CFR 80.905(a)(2) Vessels operated beyond the 20 nautical miles but not more than 100 nautical miles, must be equipped with a MF-DSC frequency transmitter, except that a MF radiotelephone installation without DSC capability is permitted until one year after the Coast Guard notifies the Commission that shore-based sea area A2 coverage is established. MI observed vessel had a MF radio transmitter on board but did not have DSC capability. Action Code: 705 - Restricted within 20 NM.
Action required: 705 - Other - as specified
Due 24 September 2025
Resolved 6 November 2025
Resolution: Received satisfactory evidence vessel replaced their MF/HF radio with DSC capability.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2025 Resolved
46 CFR 181.30-10 Portable fire extinguishers shall be installed and located to the satisfaction of the officer in charge, marine inspections. Marine Inspector found two portable fire extinguisher brackets to be damaged in passenger quarters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 15 October 2025
Resolution: Received satisfactory evidence vessel replaced fire extinguisher brackets.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 23 September 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Marine Inspector observed damaged water heater, close to failing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 15 October 2025
Resolution: Received satisfactory evidence vessel replaced water heater.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2024 Resolved
Buoyant apparatus. Each buoyant apparatus must be fitted with a lifeline, pendants, a painter, and a light. MI observed 01 in-op light with a foggy Lense and dead batteries.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 July 2024
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2024 Resolved
Batteries (less than 50 volts). (d) Acid batteries shall be located in a tray of lead or other suitable material resistant to deteriorating action by the electrolyte. MI observed metal battery box with water and insufficient insulating material
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2024
Resolution: installed fiberglass inside the tray and put a rubber mat over the top for protection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2024 Resolved
a) The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personal injury. MI observed epoxy repair on exhaust piping for the #4 main engine.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2024
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2024 Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI observed seized fire hose nozzle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2024
Resolution: Repaired nozzle
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2024 Resolved
Where flexibility is necessary a section of flexible non- metallic hose maybe used. Non-metallic hose may be used provided it is especially adapted to resist the action of oil, acid and heat, and has a wall thickness sufficient to prevent collapsing or panting. MI observed crumbling rubber hose on the #1 main engine exhaust boot.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2024
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 July 2024 Resolved
(a) Except further modified in this section, where fire extinguishing systems or equipment am not required, but are installed, the system or equipment and its installation shall,: meet the requirements of this part. MI observed inoperable fire monitor pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2024
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2024 Resolved
Ring life buoys. (b) Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed 01 life ring with broken line beckets and improperly affixed lifeline.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2024
Resolution: Removed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 9 July 2024 Resolved
Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system. MI observed in-op PA system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2024
Resolution: Repaired
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 July 2024 Resolved
(a) The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxillary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personal injury. MI observed missing lock nuts on main shaft packing gland.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2024
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 July 2024 Resolved
General requirements. (b) Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. MI observed in-op temp gauge on the starboard generator.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2024
Resolution: Gauge replaced
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 July 2024 Resolved
Electrical Installations Operating at Potentials of 50 Volts or More § 183.10-1 Application.(c) S and L. Generators and motors shall be mounted as high as practicable above the bilges to avoid damage by splash or contact with low lying vapors. They shall not be located in low or pocketed positions. Mi observed wasted engine mount on the starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2024
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 July 2024 Resolved
Hull.(a) (2) Examine and test by operation all watertight closures in the hull, decks and bulkheads. MI observed leaking engine room soft patches.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2024
Resolution: Tested soft patch with water after they cconducted repairs and no apparent leaks
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 9 July 2024 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. MI observed garbage plan with outdated information.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2024
Resolution: Updated plan
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 July 2024 Resolved
(a] All vessels except. non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed excessive leaking from rudder post when operating astern propulsion.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2024
Resolution: Vessel was in the water, no leaks.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 July 2024 Resolved
a] All vessels except. non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed violent shaking in steering system during operation as well as loose and walled out mounting hardware for the main hydraulic steering ram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2024
Resolution: Replaced hardware and bushing on the rudders. Replaced hardware and washers on steering ram mounts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2024 Resolved
(a) The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personal injury. MI observed broken potable water line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 August 2024
Resolution: Vessel cleaned the pipping for damage and pipe looked, all sat.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 July 2024 Resolved
(a) If a stability letter is issued in accordance with the requirements in 3170.120 of this chapter. it must be posted under .glass or other suitable transparent material in the pilothouse of the vessel. MI observed current stability letter was not available.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 24 July 2024
Resolution: Posted.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 August 2023 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land. MI identified both VHF radios either missing or programmed incorrect MMSI number in DSC function. Provide documentation of new MMSI number programmed into both VHF radios to the satisfaction of the MI. 47 CFR 80.905(a)(2) 60c
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 September 2023
Resolution: Received documentation vessel rep installed two new radios with DSC and MMSI numbers programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 August 2023 Resolved
Life lines shall be of a size and strength not less than 3/8-inch diameter. MI observed life lines deteriorating on three of the vessels life floats. Renew life lines to the satisfaction of the MI. 46 CFR 180.15-5(a) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
Resolution: vessel replaced grab lines.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 31 August 2023 Resolved
Under the test conditions described in 159.126 and 159.126(a) produce an effluent having fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150 milligrams per liter (Type II). MI identified a smell of raw sewage when entering the vessel to conduct the exam. Vessel's crew states that Type II system is inoperable, and system is leaking. Identify, repair and demonstrate proper operation of the type II system on board to the satisfaction of the MI. 33 CFR 159.53(b) 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 18 October 2023
Resolution: vessel sent in documentation which was reviewed, cracked piping was corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 August 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. MI observed multiple dead ended wires, exposed conductors, improperly secured connectors and, unlabeled disconnects. Operator is required to remove all abandoned cable and wiring, secure wire connections, and label electrical disconnects and panels as cited in this reference to the satisfaction of the MI. 46 CFR 183.01-5 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 25 September 2023
Resolution: Vessel provided documentation that all dead end wires had been removed and/or connections secured.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 31 August 2023 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. MI observed that Emergency escape hatch in passenger lounge dogs were wasted away and engine room entry hatch gasket was dry rotted. Operator to replace and or repair to the satisfaction of the attending MI. 46 CFR 177.35-15 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 25 September 2023
Resolution: vessel provided documenatation that wasted dogs had been renewed with new metal.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 August 2023 Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. Foam monitor was unable to obtain a prime and operate. Demonstrate proper operation of pump and foam monitor to the satisfaction of the MI. 46 CFR 181.05-5(a) 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2023
Resolution: Vessel rep provided video of fire pump and monitor obtaining prime and proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2023 Resolved
Specifications for lifesaving equipment items required to be of an approved type have been promulgated and are contained in Subchapter Q of this chapter. Starboard ring buoy plug is no longer sealed and/or watertight. Replace ring buoy with approved type to the satisfaction of the MI. 46 CFR 180.05-1(b) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 18 September 2023
Resolution: renewed life bouy
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 August 2023 Resolved
Vessel will be equipped with one fire axe located in or adjacent to the pilothouse. MI identified fire axe handle has become loose. Renew or replace fire axe to the satisfaction of the MI. 46 CFR 181.35-1(a) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 25 September 2023
Resolution: vessel replaced fire axe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2023 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation. Marine Inspector identified four locking nuts for the shaft packing in engine room had become loose and fell into the bilge. Replace locking nuts to the satisfaction of the Marine Inspector. 46 CFR 182.01-5(a) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 26 September 2023
Resolution: Vessel provided photos of all shaft bolts installed with locking nuts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 August 2023 Resolved
All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. MI identified plugs for gooseneck ducts were either corroded/seized and rubber had become dry rotted. Replace/renew plugs for ducts to the satisfaction of the MI. 46 CFR 182.20-45(d) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 26 September 2023
Resolution: Vessel installed new plugs and demonstrated proper operation of newly installed plugs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 August 2023 Resolved
The intent of this part is to insure that the scantlings, material, workmanship and arrangement of each vessel are such as to provide for safe operation. MI discovered flame locker on aft deck had holes drilled into it with line tying it to vessel scantling. In addition flame locker had incompatible chemicals in locker. Remove incompatible chemicals and properly secure locker to vessel to the satisfcation of the MI. 46 CFR 177.01-5 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 18 October 2023
Resolution: Received documenatation vessel cleared and cleaned flame locker.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 30 August 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed sight glass guard on lube oil tank was corroded away. Renew guard for sight glass to the satisfaction of the MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2023
Resolution: Received documentation guard for sight glass has been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 September 2022 Resolved
Vessel may not be operated commercially without having a valid COI onboard. Vessel operated commercially without a valid COI from 25AUG22 to 31AUG22. -46CFR176.100(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 29 September 2022
Resolved 30 September 2022
Resolution: COI was conducted on 29SEP22. All items issued as deficient resolved. COI provided to vessel on 30SEP22.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 September 2022 Resolved
Vessel shall be given protection against fire and ventilation of enclosed spaces. Vessel's Engine Room dampeners were not able to be adequately closed and had gaps of up to two (02) or three (03) inches which would permit airflow to an Engine Room Fire - 46CFR182.20-45 (Old T)
Action required: 60 - Rectify deficiencies prior to movement
Due 29 September 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22, and verified dampers were operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 September 2022 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. The vessel did not have any rails or equivalent protection at the aft of the vessel installed nor did have the means to have the required protection on board. - 46CFR177.900
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22, and verified adequate required protection (railing) in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2022 Resolved
Fuel lines shall be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration to prevent adequate protection against fire, explosion, machinery failure and personnel injury. Stbd generator fuel line to the RACOR was severely chaffed. 46CFR182.01-5 & 46CFR182.20-40 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22, and verified starboard generator fuel line properly replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 September 2022 Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personal injury. The portside inboard engine had an active lube oil leak coming from the clutch. - 46CFR182.01-5 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22. Repairs completed to satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 September 2022 Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment IAW paragraphs (b), (c) and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section. The onboard transfer hose had not had an annual hydrostatic pressure test. - 33CFR156.170 705 - Prior to transfer with hose.
Action required: 705 - Other - as specified
Due 29 September 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22, and the deficiency was rectified to satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022 Resolved
On vessels where the amount of carbon dioxide gas required in a fixed system can be supplied by one portable extinguisher, the applicator shall be installed in a fixed position outside of the space protected. The portable extinguisher in place to protect the paint locker did not have an adequate seal where the extinguisher hose enters the back of the locker. - 46CFR181.20-5 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22, and verified adequate seal where portable extinguisher hose enters paint locker.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 September 2022 Resolved
Vessel's electrical installations and equipment shall be reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. A light fixture in the aft engine room was missing its protective cover. - 46CFR183.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 30 September 2022
Resolution: MSU Houma re-attended vessel on 30SEP22, and verified proper lighting cover was instaled.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 September 2022 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operations. Floating waterlight batteries were expired. Vessel replaced batteries on the spot. - 46CFR180.70(d)
Action required: 10 - Deficiency Rectified
Due 29 September 2022
Resolved 29 September 2022
Resolution: Vessel replaced batteries on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 September 2022 Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. All four survival craft waterlights had expired batteries. Vessel replaced batteries on the spot. - 46CFR180.175(f)(4)
Action required: 10 - Deficiency Rectified
Due 29 September 2022
Resolved 29 September 2022
Resolution: Vessel replaced batteries on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 September 2022 Resolved
Piping must be suitably insulated where necessary to prevent injuries. Inboard Starboard main diesel engine was missing a section of exhaust lagging. Vessel installed exhaust lagging on the spot. - 46CFR177.970
Action required: 10 - Deficiency Rectified
Due 29 September 2022
Resolved 29 September 2022
Resolution: Vessel installed exhaust lagging on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2022 Resolved
Vessel authorized to carry portable tanks IAW 49CFR172.101, and must have additional fire protection IAW 49 CFR 176.315. Pickup tube with two 5 gallon cans of foam liquid concentrate required. Eductor with pick up tube was not operational. Vessel replaced on the spot. - 46CFR176.315
Action required: 10 - Deficiency Rectified
Due 29 September 2022
Resolved 29 September 2022
Resolution: Vessel replaced the Eductor on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2021 Resolved
46 CFR 176.810 (b)(1): Portable and semi-portable extinguishers must be inspected/ maintained in accordance with NFPA 10; Portable extinguisher hose leading into paint locker to be replaced due to dry-rot; Connection from hose to paint locker loose; must be tightened.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 24 January 2022
Resolution: Received photographic evidence of new portable fire extinguisher.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 December 2019 Resolved
The vessels annual inspection 90 day window expired on 25NOV19. Vessel did not call to schedule an inspection until 26NOV19 and did not receive an annual inspection until 02DEC19. Vessel was informed to not operate until it received its annual inspection. Vessel continued to operate from 26NOV19 to 01DEC19. 46 CFR 176.500
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 2 December 2019
Resolution: NOV issued to vessel and annual inspection completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 December 2019 Resolved
All machinery and equipment must be installed and maintained in such as manner as to afford adequate protection from causing a fire. Vessels transmission lube oil hose was excessively chafed requiring replacement. Replace hose within 14 days. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2019
Resolution: Vessel replaced lube oil hose.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 30 November 2018 Resolved
Pilothouse communications for VHF and SSB emergency power supply would not energize radios when battery charger was secured. Vessel to repair or replace emergency battery power supply. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2018
Resolved 4 December 2018
Resolution: New 12v batteries were installed.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 30 November 2018 Resolved
Primary VHF radio requires GPS Latitude/Longitude interface to enable digital select calling capability as required on passenger vessels. 47 CFR 80
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2018
Resolved 4 December 2018
Resolution: Primary VHF Radio was Digital Select Calling equipped.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 November 2018 Resolved
Engineroom port ventilation blower motor was fouled with oily debris. Crew to clean blower screen and motor housing to prevent blower motor fire. 47 CFR 182.465
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 4 December 2018
Resolution: Blower motor was cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 November 2018 Resolved
Lifefloats requires stenciling to be renewed. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2018
Resolved 4 December 2018
Resolution: Stenciling renewed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 November 2018 Resolved
Vessel has additional firefighting equipment to carry on deck portable tanks, but did not have proper COI amendments. Crew adequately trained on eauipment use. Attending MI to issue endorsement. 49 CFR 172.101
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2018
Resolved 4 December 2018
Resolution: MI issued proper COI endorsement.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 28 November 2016 Resolved
Vessel had not been logging VGP activities. DEF will be left open until next annual inspectin to verify logs have been kept properly.
Action required: 705 - Other - as specified
Resolved 30 November 2018
Resolution: VGP inspections were verified logged.

Casualty record · 1

22 January 2002Routine · role: Involved in a Marine Casualty · activity 1489456
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MISS MONA (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.