Records from 1982 to 2011. Most recent: inspection, 1 February 2011.
Inspection history · 59
1 February 2011
Drydock Exam · Annual Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3936330
25 February 2010
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3682474
21 July 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3536216
12 March 2009
Examination of Repairs · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3431080
11 March 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158844
22 January 2007
Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2859823
18 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2471104
14 July 2005
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2426707
8 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2457244
22 June 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2405468
2 March 2005
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2301920
24 November 2004
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2247306
18 October 2004
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2223359
18 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2169516
17 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2076828
1 March 2004
Deficiency Check · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2015984
23 August 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1945340
19 December 2002
COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1720952
13 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718724
25 November 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718718
18 October 2002
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1691877
25 March 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1597083
24 January 2002
Damage Survey · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1481176
22 January 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1489456
22 March 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1061473
22 February 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457883
21 January 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1048039
23 December 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438947
20 October 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421564
1 July 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 793292
27 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 794468
11 December 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408013
9 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093333
24 October 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356011
5 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184419
1 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434320
28 April 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 108055
8 November 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385336
16 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398002
28 December 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 828758
8 October 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379711
3 January 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1259029
20 September 1991
Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252307
22 March 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1305533
14 February 1991
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 909278
7 January 1991
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1215685
9 January 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913697
1 August 1989
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1041952
12 January 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889384
28 January 1988
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1015596
13 July 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328148
6 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014226
28 January 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990576
20 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978674
28 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981105
26 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280000
8 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274360
27 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274655
29 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276669
Fire Fighting › Fire Pumps › Pressure
Issued 25 February 2010
No resolution recorded
Repair/replace fire pump. Pump would not produce pressure. Pump must be self priming.
Action required: 701 - Prior to carriage of passengers/cargo
Resolution: Replaced fire pump and proved proper operation.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 February 2010
Resolved
Install fire/smoke detectors in accommodation spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2010
Resolution: Installed fire/smoke detectors in accommodation spaces.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 25 February 2010
Resolved
Repair fractured frame on stbd. main engine rear inboard mount. Prove proper weld (dye pen. test)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2010
Resolution: Repaired fractured frame on stbd. main engine rear inboard mount. Proved proper weld (dye pen. test).
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 25 February 2010
Resolved
Repair fractured mount on port engine outboard mount.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2010
Resolution: Repaired fractured mount on port engine outboard mount.
Construction/Loadline › Structures › Deck Plating
Issued 25 February 2010
Resolved
Repair 2 rear deck support poles (stanchions) in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2010
Resolution: Repaired 2 rear deck support poles (stanchions) in the engine room.
Construction/Loadline › Structures › Scuttle
Issued 25 February 2010
No resolution recorded
Repair/replace port side generator room hatch. Hatch will not dog down.
Action required: 701 - Prior to carriage of passengers/cargo
Resolution: Repaired port side generator room hatch. Hatch will now dog down.
Engineering › Fuel Oil Service System › Hose
Issued 25 February 2010
Resolved
Replace non-SAE 1942 hoses with SAE 1942 on both generators.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2010
Resolution: Replaced non-SAE 1942 hoses with SAE 1942 on both generators.
Documentation › Logs/Records › Logbook (official)
Issued 11 March 2008
Resolved
Prior to conducting passenger operations prove Fire/MOB/Abandon ship drills have been conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2008
Resolution: Vsl faxed copy of drill records from record book.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 22 January 2007
Resolved
Repair 4 cracked welds in the engine room and generator space.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 13 March 2007
Resolution: Crack welded
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 January 2007
Resolved
Repair exhaust lagging where loose on all engines.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 13 March 2007
Resolution: Lagging installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 January 2007
Resolved
Replace guards on all three main diesel engines.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 13 March 2007
Resolution: Guards installed
Electrical › Electric Generation Source (service) › Generator
Issued 22 January 2007
Resolved
Replace water pump on port generator
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 13 March 2007
Resolution: Water pump gaskets replaced, unit run and unit appeared to function as designed.
Engineering › Fuel Oil Service System › Piping
Issued 22 January 2007
Resolved
Secure and properly support all fuel lines on all three main engines and provide chaffing gear where needed.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 13 March 2007
Resolution: Lines supported and chaffing gear installed where needed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 9 November 2004
Resolved
Replace cracked glass in starboard forward cabin window.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 24 November 2004
Resolution: Window in starboard forward cabin was replaced.
Documentation › Certificates/Documents
Issued 1 March 2004
Resolved
Prove possession of endorsed/signed original Certificate of Inspection. LEGACY COMPONENT DESC: COI
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 March 2004
Resolved 4 March 2004
Documentation › Manuals/Policy Documentation
Issued 1 March 2004
Resolved
Prove possession of signature page on stability letter. LEGACY COMPONENT DESC: Stability letter
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 4 March 2004
Engineering
Issued 1 March 2004
Resolved
Lower bilge alarms in all compartments. LEGACY COMPONENT DESC: Bilge Alarms
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2004
Resolved 4 March 2004
Engineering
Issued 1 March 2004
Resolved
STBD MDE steering pump hydraulic oil return hose needs to be replaced. LEGACY COMPONENT DESC: Main Diesel Engine
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2004
Resolved 2 March 2004
Resolution: Replaced hose.
Engineering
Issued 1 March 2004
Resolved
Port fuel oil shut off reach rod needs to be repaired. LEGACY COMPONENT DESC: Fuel oil line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2004
Resolved 4 March 2004
Electrical › Lighting (service)
Issued 19 December 2002
Resolved
Provide light fixture with a guard in the pilot house IAW CFR 46 183.410 (a) LEGACY COMPONENT DESC: Lighting Fixture
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 26 December 2002
Resolution: Clear globe installed.
Engineering › Fuel Oil Service System
Issued 19 December 2002
Resolved
Place 30X30 mesh flame screens on all discharge end of fuel tank pipes IAW CFR 46 182.450 (1) (e) LEGACY COMPONENT DESC: Vent Pipe
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Proper mesh installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 December 2002
Resolved
Make repairs to both the port and starboard main engines to prevent excessive oil leaks. LEGACY COMPONENT DESC: Cylinder Head
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Both MDE''s appeared rebuilt, Captain stated that both engines had been replaced with company spare.
Electrical › Electric Supply System (service)
Issued 19 December 2002
Resolved
Provide and install metal wire hanger for electrical cables in engine room. LEGACY COMPONENT DESC: Cable
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Sat.
Engineering › Bilge Water Management System
Issued 19 December 2002
Resolved
Provide and install bilge high level alarm for eng room. LEGACY COMPONENT DESC: Interface Detector
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Test of bilge alarm sat. It appeared installed quite high in the bilge. Recommended they look into installing lower in bilge to respond quicker to a leak.
Engineering › Lubricating Oil Service System
Issued 19 December 2002
Resolved
Remove oil from engine room bilge. LEGACY COMPONENT DESC: Drain Tank
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Sat.
Engineering › Gasoline Engine (propulsion)
Issued 19 December 2002
Resolved
Properly secure fuel lines for genarators in engine room. LEGACY COMPONENT DESC: Fuel Intake (2 stroke)
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Metal clamps installed.
Engineering
Issued 19 December 2002
Resolved
Properly secure fan motor in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Replaced proper amount of mounting bolts.
Engineering › Fuel Oil Service System
Issued 19 December 2002
Resolved
Plug fuel strainers in engine room. LEGACY COMPONENT DESC: Filter
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Sat.
Electrical › Electrical Distribution System (service)
Issued 19 December 2002
Resolved
Properly label electrical distribution panel through out the vessel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Sat.
Stability › Watertight Integrity
Issued 19 December 2002
Resolved
Provide and install wedge on water tight door on aft bulkhead in passenger compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Wedges installed, after chaulk testing two doors, recommended Captain change on door gasket since it was showing signs of age. Test sat. other than that.
Electrical › Lighting (emergency)
Issued 19 December 2002
Resolved
Prove operation of emergency lighting though out vessel.
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 26 December 2002
Resolution: Sat.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 24 January 2002
Resolved
Make permanent repairs to exhaust system on generators where red hand temporary patches are installed.
Condition: Unknown
Due 7 March 2002
Resolved 12 March 2002
Resolution: Repaired
Communications › Internal Communications System
Issued 24 January 2002
Resolved
Install intercom or P.A. system in lower passenger compartment IAW 46 CFR 184.60.
Condition: Improper Installation
Due 7 March 2002
Resolved 12 March 2002
Resolution: New P.A. system installed
Construction/Loadline › Markings
Issued 24 January 2002
Resolved
Paint draft marks on vessel IAW 46 CFR 185.602(c)(1). LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper Installation
Due 7 March 2002
Resolved 12 March 2002
Resolution: Draft marks painted.
Engineering › Freshwater System (air cooling)
Issued 24 January 2002
Resolved
Repair A/C intake water line where it penatrates forward engineroom bulkhead.
Condition: Improper/Lack of Maintenance
Due 7 March 2002
Resolved 12 March 2002
Resolution: Repaired
Engineering
Issued 22 February 2001
Resolved
PROVE PROPER OPERATION OF STBD SIDE FUEL SHUT OFF VALVE.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 23 December 1999
Resolved
Provides batteries with expiration dates for lights on all life jackets.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Accommodation/Occupational Safety
Issued 23 December 1999
Resolved
Replace relief valve on hot water heater with 100 psi relief valve.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Lifesaving
Issued 23 December 1999
Resolved
Attach paddles to life floats.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Lifesaving
Issued 23 December 1999
Resolved
Properly secure life floats with proper weak links.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Construction/Loadline
Issued 23 December 1999
Resolved
Make proper repairs to fwd water tight hatch.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Accommodation/Occupational Safety
Issued 23 December 1999
Resolved
Replace plastic dryer duct with metalic duct.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Construction/Loadline
Issued 23 December 1999
Resolved
Provide opening device for emergency escape in steering compartment.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Navigation
Issued 23 December 1999
Resolved
Make proper repairs to steering ram stop in steering room.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Accommodation/Occupational Safety
Issued 23 December 1999
Resolved
Gouge and re-weld starboard side stairs on main deck.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Navigation
Issued 23 December 1999
Resolved
Provide light list for vessel's area of operation.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Lifesaving
Issued 23 December 1999
Resolved
Replace faded retro tape on all lifejackets.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Construction/Loadline
Issued 27 May 1998
Resolved
PERMANENTLY INSTALL DRAFT MARKS AS PER 46CFR185.602. PROVIDE CG INSPECTOR WITH PROFESSIONAL ENGINEERS OR NAVAL ARCHITECHS VERIFICATION OF DRAFT MARK LOCATION.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Documentation
Issued 1 November 1995
Resolved
PROVIDE ON BOARD A VALID FCC SAFETY RADIO TELEPHONEY CERTIFICATE.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Engineering
Issued 3 January 1992
Resolved
PROVE OPERATION OF THE MAIN ENGINE REMOTE START AND STOP SWITCHES.
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Construction/Loadline
Issued 14 February 1991
Resolved
MAKE PERMANENT REPAIRS TO 4" PIPE RUB RAIL DAMAGE LOCATED PORT AND STBD_x001C_ SIDE FWD AND PORT AFT STERN.
Condition: Unknown
Due 14 February 1991
Resolved 14 February 1991
Construction/Loadline
Issued 14 February 1991
Resolved
VEE OUT AND REWELD CRACKED WELD IN FOREPEAK IN WAY OF WEB FRAME #1 AND PORTLONGITUDINAL FRAME #10 CONNECTION.
Condition: Unknown
Due 14 February 1991
Resolved 14 February 1991
Navigation
Issued 7 January 1991
Resolved
REPAIR OR RENEW THE SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Construction/Loadline
Issued 1 August 1989
Resolved
CROP AND RENEW IN KIND THREE (3) AREAS OF TEMPORARY REPAIRS (CLAD WELDS) IN SIDE PLATE, PORT SIDE.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Engineering
Issued 1 August 1989
Resolved
REPAIR TIP DAMAGE TO PROPELLERS.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 1 August 1989
Resolved
REPAIR/STRAIGHTEN STBD RUDDER POST AND REPLACE RUDDER POST BUSHING.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989