04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 March 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The high water alarm in the lazarette was inoperable.
Action required: 705 - Other - as specified
Resolved 27 March 2026
Resolution: High water alarm was made operable and visual light at the helm is fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 March 2026
Resolved
Life floats must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Painter and weak-link were not installed on the vessel.
Action required: 705 - Other - as specified
Resolved 27 March 2026
Resolution: Painter provided and properly installed with weak-link.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 March 2026
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Brackets for portable extinguisher were wasted, missing or the wrong size.
Action required: 705 - Other - as specified
Resolved 27 March 2026
Resolution: Brackets installesz and portable extinguishers mounted.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 27 March 2026
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations. Satellite phone and EPIRB registration were not on the vessel. Vessel is limited to operation not more than 20 miles from land until a working Satellite phone is provided.
Action required: 705 - Other - as specified
Resolved 27 March 2026
Resolution: Owner provided documentation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2026
Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Provide positive locking mechanism for closing engine vents.
Action required: 705 - Other - as specified
Resolved 27 March 2026
Resolution: Latches were installed to positively secure air vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2026
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Provide double clamp for engine raw water hose.
Action required: 705 - Other - as specified
Resolved 27 March 2026
Resolution: Crew installed missing hose clamp.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2024
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests; vessel's FireBoy system was not approved for continued use by servicing company.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2024
Resolved 2 May 2024
Resolution: New System installed and serviced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure; vessel experienced transmission failure while underway w/ pax.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2024
Resolved 1 May 2024
Resolution: Satisfactory Sea trials conducted sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2022
Resolved
46CFR182.610 (1)- A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds
Action required: 60 - Rectify deficiencies prior to movement
Due 6 May 2022
Resolved 10 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2022
Resolved
The vessel must be provided with a satisfactory arrangement for draining any watertight compartment to include bilge pumps; the bilge pump in the engine compartment is not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2022
Resolution: Vessel's bilge pump tested sat
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 March 2022
Resolved
Each life float must be attached to a sea painter or properly tethered together to a sea painter; the tether line between the small life floats is deteriorated and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2022
Resolution: Line replaced
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 March 2022
Resolved
ach life float paddle must be lashed to the float to which it belongs; all of the paddles are loose and not so attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 March 2022
Resolved
A vessel must have navigation lights that are in compliance with the International and Inland Navigation Rules; numerous navigation lights are not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2022
Resolution: lIGHTS REPAIRED
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 March 2022
Resolved
A vessel of 12 meters or more in length must be equipped with a whistle and a bell; the vessel does not have a bell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2022
Resolution: aIR HORN PLACED ONBOARD
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 March 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights; the vessel is not so equipped.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 March 2022
Resolution: NEW FLASH LIGHTS WERE PLACED ONBOARD
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 March 2022
Resolved
Each life float must meet the specifications in accordance with the approval number 160.027; the man basket on the large life float is deteriorated, repair with approved type material meeting the original specifications or replace the life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 10 October 2022
Resolution: New engine istallation completed and operational test conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 March 2022
Resolved
Each life float must meet the specifications in accordance with the approval number 160.027; the large life float is not the proper color as specified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 10 October 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 March 2022
Resolved
The Captain of the vessel must have a FCC Radio Operator Permit; the Captain does not posses the proper license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 10 October 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
Resolution: Certificate issued
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 March 2022
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date charts and navigation publications; the vessel does not have tide and tidal current tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 March 2022
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date charts and navigation publications; the vessel does not have a copy of the USCG Local Notice to Mariners.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 10 October 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 March 2022
Resolved
Crew training shall be logged or otherwise documented, the training entry shall include the date, time and brief description; the vessel is not keeping the required training records.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
Resolution: Master produced logs
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 March 2022
Resolved
An Emergency Instructions Placard must be posted and shall contain instructions for "Rough Weather at Sea", "Man Overboard" and "Fire"; the vessel's Emergency Instructions Placard is incomplete.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 March 2022
Resolved
The master of the vessel shall ensure that the EPIRB / is tested monthly / test is logged or otherwise documented / battery is replaced after use or prior to its expiration date; the vessel has no records/log entry's indicating such tests are being carried out.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 March 2022
Resolved
Life saving equipment must be in good working order and ready for immediate use at all times. The owner/operator shall make sure the maintenance is being carried out in accordance with the manufacturers instructions, the inspection and maintenance of life saving equipment shall be logged or otherwise documented; the vessel has no records of such maintenance being carried out.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
Resolution: Log started
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 March 2022
Resolved
A vessel greater than 40 feet must have a written Garbage Management Plan describing procedures for minimizing, collecting, processing, storing, and discharging garbage, and designating the person who is in charge of carrying out the plan; the vessel has no such written plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 18 March 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 April 2021
Resolved
Provisions shall be made for securing ventilation closures when space is equipped with fixed/pre-engineered fire extinguishing system. Existing ventilation closure(s) was inoperable due to seized hardware.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 1 September 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2021
Resolved
Vessels ventilation closure devices shall be marked to indicate location/directions for operation. Existing markings were missing/broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 28 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2021
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with a permanent type connector. Existing battery terminal(s) were found loose/corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 28 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2021
Resolved
Vessel shall be equipped with bilge pumps. Existing bilge pump IWO engine room was found unsecured (not permanently mounted).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 1 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2021
Resolved
At each inspection, the Marine Inspector shall examine the vessels bilges to see that there is no accumulation of oil or other matter which might create a fire hazard. Vessels bilges require cleaning to remove debris/trash/residual oils.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 28 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2021
Resolved
Vessel required to be fitted with peripheral deck railings. Existing peripheral railings were found loose, broken/missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 14 October 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 April 2021
Resolved
Vessel required to be equipped with FCC Safety Radio-Telephony Certificate. Existing FCC Safety Radio-telephony certificate has expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 14 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2021
Resolved
When stowed in tiers, life floats must be kept apart by spacers. Existing stowage of life floats are missing spacers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 28 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 April 2021
Resolved
Vessel required to be equipped with six day (orange) and six day night (red) visual distress signals. Vessel is equipped with eight day/night visual distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 28 June 2021
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 5 April 2021
Resolved
Vessel required to be equipped with MF/HF radio-telephone. Vessel's satellite phone's base/charging station was found inoperable due to corrosion/water intrusion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 14 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 April 2021
Resolved
Vessel required to be equipped with current/up to date navigational publications for areas transited. Existing navigational publications were found expired/out of date.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 1 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2021
Resolved
Vessel required to be equipped with seating for passengers. Existing seating IWO main cabin, starboard side (bench seat) was damaged/fractured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 1 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 April 2021
Resolved
Owner/Operator shall provide a current/up to date roster of employees enrolled in a drug testing consortium (program). Existing list of enrolled employees was found expired/out of date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 14 October 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 July 2020
Resolved
Scope of annual inspection is same as initial certification to ensure vessel is fit for service and route intended. Attending Inspector noted fractured laminate IWO starboard main deck @ side shell (main cabin). Damage resulted from heavy weather damage approx. two weeks prior. *Temporary repairs are authorized until permanent repairs can be effected.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 1 September 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 1 July 2020
Resolved
Scope of annual inspection is same as initial certification to ensure vessel is fit for service and route intended. Attending Inspector noted fractured seam IWO main deck @ transom.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 5 April 2021
Resolution: Attending Inspector(s) verified repairs IWO main deck @ transom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2020
Resolved
Vessel shall be capable of being dewatered from each watertight compartment. Attending Inspector(s) noted inoperable float switch for fwd bilge pump & lazarette bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2020
Resolution: Attending Inspector verified repairs to float switches for fwd compartment/lazarette.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 July 2020
Resolved
Scope of annual inspection is same as initial certifcation to ensure vessel is fit for service and route intended. Attending Inspector identified "soft spots" in vessels aft main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 15 March 2022
Resolution: Trouble area replaced during drydock exam. See narrative in activity number 7351265 for details.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2020
Resolved
Vessel required to be fitted with three fire buckets. Vessel is not equipped with three fire buckets (min. size @ 2.5 gal.).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2020
Resolution: Atttending Inspector(s) verified carrige of fire buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2020
Resolved
Vessels required to be fitted with emergency fuel shut-off valves with markings. Vessels existing fuel shut-off valves are missing operating instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 28 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2020
Resolved
Vessels PFD's are required to be fitted with PFD lights. Existing PFD lights are extinguished/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2020
Resolution: Attending Inspector verified operation of PFD lights.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 July 2020
Resolved
Vessels water lights require annual servicing. Vessels existing floating water lights require battery renewals/servicing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 2 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2020
Resolved
Vessel required to be fitted with ventilation closure devices. Vessel's ventilation closure devices are not marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 28 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 1 July 2020
Resolved
Vessel's electrical junction boxes required to be fitted with protective cover. Exisitng junction box IWO engine room fwd bulkhead, port side missing protective cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2020
Resolved 2 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2020
Resolved
Port navigational side light was not displaying proper intensity ("dim").
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified operational of navigational side lights.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2020
Resolved
Vessels stern light was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified operation of stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 April 2020
Resolved
Vessels life floats required servicing/repair (outer jacketing, netting, markings).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2020
Resolution: Attending Inspector verified repairs made to life floats.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2020
Resolved
Portable fire extinguisher & bracket assembly IWO port/aft cabin wall was found wasted/corroded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2020
Resolution: Attending Inspector verified renewal of portable extinguisher & repairs to bracket.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2020
Resolved
Pre-engineered fire extinguishing system (FIREBOY) IWO engine room/machinery space required servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2020
Resolution: Attending Inspector verified renewal of pre-engineered fire extinguishing system (bottle only).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2020
Resolved
Portable fire extinguishers require servicing (expired March 2020).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2020
Resolution: Attending Inspector verified annual servicing of portable fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2019
Resolved
Portable fire extinguisher bracket located in fwd compartment (port side) required replacement due to corrosion/wastage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of (new) portable fire extinguisher bracket.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 May 2019
Resolved
Vessel's satellite phone's base station was not capable of charging/interfacing with the external antenna due to corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 5 April 2021
Resolution: Satellite phone cradle installed/tested.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2019
Resolved
Navigational publications for areas transited were expired/out of date. Missing USCG Light List and NOAA Tidal/Current Tables.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2019
Resolved
Vessels navigational/marine charts for areas transited were found expired/out of date. Missing marine chart for AICW (#11534).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 15 May 2020
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2019
Resolved
Vessel did not carry/employ a suitable first aid kit on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified carriage of proper type/size of first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Weak links for life float installation was not configured properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation for life float weak links.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2019
Resolved
EPIRB failed "self test" function, requires servicing/replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of (new) EPIRB and witnessed operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019
Resolved
Port & Starboard fuel fill(s) are missing bonding straps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of bonding straps for port/starboard fuel fills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Floating water light for ring life buoy required replacement due to condition/serviceablity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified renewal of water light for ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Floating water light for life float installation(s) requires replacement due to condition/serviceability.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified renewal of water lights for life float installation.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 13 May 2019
Resolved
Vessels radar was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 15 May 2020
Resolution: Attending Inspector verified operation of installed radar.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2019
Resolved
Vessel did not carry two portable lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified carriage of two portable lights.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2019
Resolved
Vessel not equipped with ventilation closure devices for port/starboard gunwale area (natural ventilation). *Space is equipped with a pre-engineered fire extinguishing system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 1 July 2020
Resolution: Attending Inspector(s) verified installation of ventilation closure devices for machinery space/engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2019
Resolved
Paddles for life floats were missing markings (vessels name).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 15 May 2020
Resolution: Attending Inspector verified markings for life float paddles.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 18 June 2018
Resolved
Vessel did not have proper type/quantity of visual distress signals on board
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified carriage of proper qty/type of visual distress signals for assigned route.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 June 2018
Resolved
The required first aid kit was found improper for vessels route/service (expired items).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified carriage/renewal of proper size/type of first aid kit.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 June 2018
Resolved
PFD stowage markings were missing/improper.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified PFD stowage markings.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 June 2018
Resolved
Mounting brackets for portable fire extinguishers were wasted/required repair.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified renewal of portable fire extinguisher mounting brackets.
Documentation › Markings/Placards › Warning Signs
Issued 18 June 2018
Resolved
Vessels emergency exits were not properly marked/identified.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified posting of emergency escape instructions IWO main cabin entrance.
Fire Fighting › Fire Bucket › Quantity
Issued 18 June 2018
Resolved
Vessel did not have required quantity of fire buckets on board.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified carriage of proper type/qty of fire buckets.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 18 June 2018
Resolved
Vessel was missing electrical covers for junction boxes IVO port main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified renewal of junction box cover/faceplate IWO port gunwale.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 18 June 2018
Resolved
Vessels crew not properly trained in first aid/CPR (at least 50% of crew).
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified crew training (First Aid/CPR) for at least 50% of crew.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 February 2017
Resolved
Vessel did not have the required emergency instructions posted on board.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified posting of Emergency Instructions.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017
Resolved
Vessels VHF-FM marine radios were not programmed with MMSI number (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the programming of VHF-FM (DSC) radios.
Communications › Alarms/Indicators › High Water Alarm
Issued 23 February 2017
Resolved
Vessels bilge/high water alarms failed to operate during testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 24 February 2017
Resolution: Attending Inspector performed operational test of bilge high water alarms. Test sat.
Engineering › Bilge Water Management System › Pump
Issued 23 February 2017
Resolved
Forward bilge switch for submersible electric bilge pump was inoperable at time of testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 24 February 2017
Resolution: Attending Inspector performed an operational test of vessels forward electric submersible bilge pump switch, test sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017
Resolved
Center VHF-FM marine radio failed operational test *failed to send/recieve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified repairs made to center VHF-FM radio. Performed satisfactory operational test.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 February 2017
Resolved
Vessel did not carry current/up to date navigation publictions (USCG Light List, Tidal/Current Tables, Navigation Rules)
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the carriage of current/up to date navigation publications for areas transited.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 23 February 2017
Resolved
Vessels pre-engineered fire suppression system failed to shut main engine down during operational testing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 24 February 2017
Resolution: Attending Inspector performed an operational test of vessels pre-engineered fire suppression/shut down system, test sat.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 February 2017
Resolved
Vessel does not maintain a garbage log (>40')
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the carriage of garbage log book.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2017
Resolved
Navigation side light lens' are frosted (repair/replace)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector witnessed repairs made to side navigation lights.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 February 2017
Resolved
Repair life float exterior coating IAW manufacturers instructions/recommendations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified repairs made to life floats.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 February 2017
Resolved
Main engine starting battery terminal are heavily corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the removal of oxidation from marine battery installation.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 February 2017
Resolved
Vessels main engine exhaust piping was not double hose clamped at flexible joints/connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the installation of additional hose clamps for exhaust joints.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 February 2017
Resolved
Provide additional markings to show location of emergency fuel shut off valves and provide operating instructions.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspectors verified markings/operating instructions for emergency fuel shut off valves.