Records from 1992 to 2026. Most recent: inspection, 30 April 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 April 2026
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2026
Resolution: Certificates posted in the cabin
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 April 2026
Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2026
Resolution: Stability Letter posted in the cabin
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 April 2026
Resolved
The person in command of a documented vessel must produce the original Certificate of Documentation currently in effect for that vessel upon the demand of any person acting in an official public capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2026
Resolution: Original COD placed onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel had water pump failure on STBD Main engine. Water pump must be repaired prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Impellar was repaired and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2023
Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office, Marine Inspection Office, or Coast Guard Group Office whenever a vessel is involved in a marine casualty;Vessel was involved in an unintended grounding on February 21, 2023 and failed to immediately notify the Coast Guard.
Action required: 10 - Deficiency Rectified
Due 23 February 2023
Resolved 23 February 2023
Resolution: Discussed reporting requirements with the master and company rep ([name withheld]). IOs will be taking enforcement action.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 February 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made;Vessel damaged its propeller during an unintended grounding. Repairs shall be made in kind and verified by a marine inspector before returning to service.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2023
Resolved 23 February 2023
Resolution: Conducted sea trials with the new propeller. All satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 February 2022
Resolved
Vessel required to be equipped with navigational lights as prescribed by regulation(s). Fractured weldments noted IWO upper mast assembly.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 28 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 February 2022
Resolved
Vessel required to be fitted with operable navigational lights as prescribed by regulation(s). Vessels forward mast head light was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 28 February 2022
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 1 February 2022
Resolved
Vessel required to be equipped with HF/SSB radiotelephone. Existing SSB radiotelephone is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 12 April 2023
Resolution: Local FCC rep. affirmed that FCC exemption has been paid for. Awaiting the paper copy. FCC is way behind on paperwork & receipt of payment satisfies the requirement. Vsl equipped with Sat phone and charging equipment. Sat op test conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2022
Resolved
Vessel required to be equipped with a suitable steering system. Existing hardware between hydraulic steering ram and tiller arm is improperly size/configured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 3 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 February 2022
Resolved
PFD's are required to be equipped/fitted with PFD lights. Existing PFD lights were found extinguished due to dead batteries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 28 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 February 2022
Resolved
Vessel's propulsion system must be suitable in type and design for propulsion requirements of the hull. Excessive vibration noted IWO port propulsion shaft. Further inspection required to determine cause.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 3 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Excessive leaks noted IWO port & starboard shaft seals located in machinery space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 28 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2022
Resolved
Vessels steering systems must be of adequate strength and capable of steering vessel at all service speeds. Excessive leaks noted IWO rudder post.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 28 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2022
Resolved
Vessels peripheral decks are required to be equipped with rail courses. Port & starboard embarkation stations are not equipped with proper rail courses/safety chains.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 28 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 February 2022
Resolved
Vessel required to be equipped with navigational side lights as prescribed by regulation(s). Existing starboard navigational side light was dim/partially extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2022
Resolved 3 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022
Resolved
Vessel required to be equipped with lifesaving equipment for routes and conditions prescribed. Existing life float netting requires replacement due to (UV) deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 3 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022
Resolved
Vessel required to be equipped with lifesaving equipment for routes and conditions prescribed. Life float markings/retro-reflective tape requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 28 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2022
Resolved
Vessel required to be equipped with emergency fuel shut-off valves with markings. Existing emergency fuel shut-off valves are missing markings to indicate operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 28 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2022
Resolved
Vessel required to be equipped/carry on board at least two portable lights. Vessel was not equipped with two portable lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 28 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 February 2022
Resolved
Vessel required to carry current/up to date marine charts of areas transited. Existing marine charts were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 3 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 February 2022
Resolved
Vessel required to be equipped with current/up to date navigational publications for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 3 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2021
Resolved
Vessels watertight hatches are required to be marked "WATERTIGHT HATCH KEEP CLOSED" (min. 1" lettering). Existing watertight hatches are not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2021
Resolved 14 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 June 2021
Resolved
Vessel required to be equipped with current/up to date marine charts for areas transited. Existing charts #11520, 11534 & 11535 were missing/outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2021
Resolved 27 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 June 2021
Resolved
Vessel required to carry current/up to date navigational publications for areas transited/operated. Existing navigational publications were expired/outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2021
Resolved 27 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2021
Resolved
Vessel required to be equipped with peripheral hand rails. Existing hand rail (stanchion) IWO port bow was found fractured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2021
Resolved 28 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2021
Resolved
Vessel required to be equipped with bilge pumps capable of deweatering spaces/voids. Existing float switch for electric submersible bilge pump in way of forward/lower compartment was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 27 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2021
Resolved
Vessels main deck hatches are required to be watertight to prevent downflooding of vessel. Existing engine room hatch (aluminum) is not secured with mechanical fasteners.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 14 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 25 June 2021
Resolved
Vessel required to be equipped with an operable radar. Existing radar is not operational (unable to acquire input).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 14 October 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 May 2021
Resolved
A pre-engineered fixed fire extinguishing system must be installed in accordance with the manufacturers instructions. The system has been installed with two alarm indicators, one is intended as a backup; prove this is in accordance with the manufacturers instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 May 2021
Resolved
A pre-engineered fixed fire extinguishing system must be capable of manual activation; the installed system does not currently have a manual pull cable installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2020
Resolved
Vessel's exhaust pipe discharge that terminates at the transom must be located as far outboard as practicable. Existing FRP exhaust piping IWO port transom has active leak at "tabbing" where pipe penetrates transom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2020
Resolved
Vessels exhaust system shall be arranged to provide access to allow complete inspection. Existing port/starboard mufflers show signs of wear/fatigue/leaking. Owner/Operator to remove existing mufflers for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 November 2020
Resolved
At each subsequent inspection, vessel is subject to inspection of all accessible parts of the exterior and interior of the hull, watertight bulkheads and weather decks. Attending Inspector(s) noted "open" communication between the lazarette and aft void via "half round" bottom longitudinals (previously cut/modified). Owner/Operator to properly "seal" bottom longitudinals to ensure watertight intergrity.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2020
Resolved
The discharge ends of fuel tank vent pipes shall be equipped with removable flame screens. Remove existing fuel tank vents for further inspection/cleaning of flame screen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2020
Resolved
Vessel is subject to subsequent inspections of installed machinery. Starboard main diesel engine main oil seal was found leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2020
Resolved
Vessels emergency fuel shut-off valve(s) are required to be marked/labeled. Existing fuel shut-off valve access cover not properly marked nor is the pull rings for the port/starboard fuel supply shut-off valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Transverse framing IWO port main diesel engine (fwd) was missing fastener.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Port main diesel engine fuel injection pump was found leaking (minor).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Delamination of FRP (from previous repairs) were noted IWO fwd watertight bulkhead in battery compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 6 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Open bulkhead penetration noted IWO fwd watertight bulkhead in battery compartment under helm/console.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 5 November 2020
Resolution: Attending Inspector(s) verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Attending Inspector(s) noted "soft spots" IWO bow cap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Attending Inspector(s) noted rot IWO anchor mountings @ bow cap. Temporary repairs are authorized until permanent repairs can be effected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 June 2020
Resolved
The scope of the annual inspection is the same as the initial certification to ensure vessel remains fit for service and route intended. Vessels navigational lights (NUC) were found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 5 November 2020
Resolution: Attending Inspector(s) verified operation of vessels navigational lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2020
Resolved
Vessels ring life buoy is required to be fitted with a serviceable floating water light. Existing floating water light battery required replacement (annual).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 5 November 2020
Resolution: Attending Inspector(s) verified renewal of floating water light batteries.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2020
Resolved
Vessel required to be fitted with two portable lights. Vessel is missing required portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 5 November 2020
Resolution: Attending Inspector(s) verified carriage of two portable lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2020
Resolved
Vessel required to be fitted with emergency fuel shut-off valves. Existing fuel shut-off valve access cover was found damaged/cracked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 5 November 2020
Resolution: Attending Inspector(s) verified renewal of access covers for emergency fuel shut-off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019
Resolved
Aft water lubricated bearings are worn/requires replacement.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2019
Resolved 6 December 2019
Resolution: Attending Inspector(s) verified renewal of aft bearings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019
Resolved
Port trim tab assembly was missing/diconnected from vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 December 2019
Resolved
Fractures/rot noted IWO inboard/outboard stringers for port main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 December 2019
Resolved
Fractured "tabbing" IWO port/starboard longitudinal bottom stringers IWO aft void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 December 2019
Resolved
Fractures in "tabbing" IWO port transverse bottom stringers (side shell to outboard engine stringer).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 December 2019
Resolved
Vertical main deck supports detached from bottom transverse framing in way of aft void (fwd).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of brackets for vertical deck supports.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 December 2019
Resolved
Main deck transverse/longitudinal framing was "hanging" from overhead.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2019
Resolution: Attending Inspector(s) verified repairs made to main deck transverse framing.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 3 December 2019
Resolved
Fracture/rot noted IWO main transverse watertight bulkhead for aft void/machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 3 December 2019
Resolved
Missing handle for ball valve IWO machinery space (port/aft of fuel tank @ side shell).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2019
Resolved
Engine/motor mounts required (re) adjustment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of (new) engine mounts for starboard main diesel engine and adjustment of port main diesel engine mounts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2019
Resolved
Transverse watertight bulkhead between aft void/lazarette showing signs of rot. Bulkhead requires repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2019
Resolved
Excessive "furring" noted IWO main deck framing on starboard side/fwd engine room IVO ventilation trunk.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 6 May 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2019
Resolved
Stress cracking noted IWO starboard/outboard scupper and lower corner of stern door (port) along the main deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 27 December 2019
Resolution: Attending Inspector(s) witnessed repairs made IWO starboard/outboard scupper.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 3 December 2019
Resolved
Fracturing noted IWO fwd lower decking/port bulkhead for head. Areas to be ground for further inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 27 December 2019
Resolution: Attending Inspector(s) verified repairs made IWO fwd/lower decking.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2019
Resolved
FRP IWO fwd bulkhead for battery compartment & aft bulkhead of fwd compartment (under ladder) was found delaminated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 27 December 2019
Resolution: Attending Inspector verified repairs made IWO fwd compartment bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019
Resolved
Corrosion of fuel hose end fittings was noted IWO port/starboard main diesel engines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2020
Resolved 6 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019
Resolved
Hydraulic steering hoses for steering system IWO lazarette were found "blistered". Hoses require replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 29 January 2020
Resolution: Attending Inspector(s) verified renewal of hydraulic steering flexible hoses.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 December 2019
Resolved
Main deck hatch for machinery space was not made watertight (gasketing) and was not secured with mechanical fasteners.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of gasketing/mounting hardware for main deck hatch for machinery space/engine room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2019
Resolved
Attending Inspector(s) called out "open" bulkhead penetrations IWO watertight bulkheads between battery comparment/machinery space/aft void/lazarette.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified sealing of bulkhead penetrations (throughout).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2019
Resolved
Improper fuse block installed IWO console. Current configuration accepts "blade" style fuses which are not UL approved.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of proper type/size of fuse block.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 May 2019
Resolved
Single Side Band radio-telephone was inoperable at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Owner/operator elected to provide a satellite phone in lieu of servicing/replacing existing SSB radio-telephone.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 May 2019
Resolved
Original Certificate of Documentation not on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector verified carriage of current/up to date COD on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2019
Resolved
Navigational publications were expired/outdated for areas transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019
Resolved
Upper red light for not under command was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified operation of navigational (NUC) lights.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2019
Resolved
EPIRB battery expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified renewal of EPIRB.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2019
Resolved
EPIRB Hydro-static release unit (HRU) expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified EPIRB HRU installation/markings.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2019
Resolved
Floating water lights for life float arrangement(s) required replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified renewal of batteries IWO floating water lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2019
Resolved
Electric submersible bilge pumps were not properly mounted/secured to prevent movement/floating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of electric submersible bilge pumps.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2019
Resolved
Bilge high water alarm for lazarette inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) witnessed operational test of bilge high water alarm IWO lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019
Resolved
Renew fuel oil supply line between Racor filters and port main diesel engine due to line being crimped IWO transmission mount and bottom longitudinal/stringer.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified removal of crimped fuel oil return line for port MDE and witnessed installation of new fuel line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019
Resolved
Isolate/repair source of raw water leaks IWO void #3 (aft of machinery space). Source suspected of being flexible hose connections for main diesel engine exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) performed visual inspection of exhaust system IWO flexible hose connections/coupling, no leaks noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019
Resolved
Provide/install bonding straps for port/starboard fuel tank fill(s).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified fuel fill/tank installations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2018
Resolved
Raw water thru-hull valve assembly (valve/piping) for port main diesel engine was found leaking/loose. Temp. repairs authorized until next scheduled haulout (DEC2018).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 February 2019
Resolution: Attending Inspector(s) verified repairs made to port MDE raw water thru-hull valve.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 November 2018
Resolved
Pre-engineered fire extinguishing system (Fireboy) was noted in poor condition (excessive wastage on bottle) and discharged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2018
Resolved 13 February 2019
Resolution: Attending Inspector(s) verified installation of (new) pre-engineered fire suppression system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 November 2018
Resolved
Attending Inspector(s) noted open penetrations IWO fwd machinery space bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 February 2019
Resolution: Attending Inspector(s) verified repairs/corrections made IWO fwd machinery space bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 November 2018
Resolved
Attending Inspector(s) identified source of exhaust leak IWO Void #3. A fractured FRP pipe was noted IWO starboard exhaust pipe (fwd).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 February 2019
Resolution: Attending Inspector(s) verified repairs made to starboard exhaust piping IWO Void #3.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2018
Resolved
Electric submersible bilge pumps are not properly secured to prevent movement/floating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 February 2019
Resolution: Attending Inspector(s) verified installation/securing of electric submersible bilge pumps.
Lifesaving › Lifefloat › Float-free Link
Issued 11 June 2018
Resolved
Float free links were missing required identification/markings/tags.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation of weak links for life floats.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 11 June 2018
Resolved
Visual distress signals on board the vessel were expired.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified carriage of proper type/qty of visual distress signals for vessels route.
Communications › Alarms/Indicators › High Water Alarm
Issued 11 June 2018
Resolved
Void #3 high water alarm failed to alarm when activated.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) performed operational test of bilge high water alarm IWO Void #3.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2018
Resolved
Mast headlight lens was severely darkened/opaque prohibiting proper display of navigation light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified renewal of mast light lens assembly.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 June 2018
Resolved
Retroreflective material on vessel's life floats worn/required replacement.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified renewal of retro-reflective material IWO life floats.
Documentation › Markings/Placards › Warning Signs
Issued 11 June 2018
Resolved
Vessel's emergency escape from pilothouse was not properly marked (EMERGENCY EXIT KEEP CLEAR).
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation/posting of emergency escape markigns IWO main cabin door.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 June 2018
Resolved
Flexible piping IVO void #3 exhaust system deteriorated/leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation/renewal of flexible exhaust hose assemblies IWO void #3.
Engineering › Bilge Water Management System › Valve
Issued 11 June 2018
Resolved
Vessels through hull valve for bilge piping was incorrectly configured IWO port void (outboard battery bank).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified thru-hull valve assemblies/configurations.
Fire Fighting › Fire Bucket › Stenciling
Issued 11 June 2018
Resolved
Fire bucket markings were illegible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified fire bucket markings.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 June 2018
Resolved
Vesels VHF-FM radio-telephones were not properly configured/interfaced with GPS (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation of VHF-FM radiotelephone/GPS units.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 June 2018
Resolved
Vessels VHF-FM radio-telephones were not programmed with MMSI ID numbers (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified programming of VHF-FM radiotelephones.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 June 2018
Resolved
Cooling fans IWO bridge were powered by household extension cord.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified junction box installation for bridge fans.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 11 June 2018
Resolved
Main deck floor frames IWO cabin/pilothouse were found wasted/corroded/detached from main deck structure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 February 2019
Resolution: Attending Inspector(s) verified repairs made IWO main deck (interior cabin).
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2017
Resolved
Excavate epoxy resin from port & starboard rudder post bushings and rebed with marine grade epoxy.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 16 November 2017
Resolution: Attending Inspectors verified removal of existing epoxy resin and re-bedding of (new) epoxy resin in/around port/starboard rudder posts.
Engineering › Steering Gear System › Linkage
Issued 15 November 2017
Resolved
Isolate/repair excessive play in port & starboard rudders.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 16 November 2017
Resolution: Attending Inspectors verified adjustments made IWO port/starboard rudder post keyway/tiller arms.
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2017
Resolved
Grind hull laminate IWO port main diesel engine raw water thru-hull fitting (interior) for further inspection.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 13 December 2017
Resolution: Attending Inspectors verified repairs IWO interior hull laminate @ port main diesel engine raw water intake/thru-hull valve.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 November 2017
Resolved
Renew brass nipple IWO starboard main diesel engine raw water intake piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 16 November 2017
Resolution: Attending Inspectors verified installation of (new) brass nipple IWO starboard main diesel engine raw water intake/thru-hull valve.
Stability › Watertight Integrity › General
Issued 31 March 2017
Resolved
Provide tethering devices for main deck water-tight hatch covers.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified installation of tethering devices for main deck hatches.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 March 2017
Resolved
Provide double hose clamps in way of starboard main diesel engine raw water hose/piping (between sea valve and cooling pump)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified installation of double hose clamps in way of starboard main engine raw water pump.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 March 2017
Resolved
Provide emergency fuel shut-off valve markings (operating instructions)
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified markings/operating instructions for emergency fuel shut off valves.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 March 2017
Resolved
Repair starboard emergency fuel shut-off valve assembly (broken cable)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified repairs made to starboard emergency fuel shut off valve. Performed operational test, test sat.
Fire Fighting › Ventilation Systems › Ducts
Issued 31 March 2017
Resolved
Provide markings (operating instructions) for ventilation closure devices.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified markings/operating instructions for ventilation closure for machinery space.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 March 2017
Resolved
Provide two emergency lights.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified carriage of two portable lights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 March 2017
Resolved
Renew expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified contents of first aid kit.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 31 March 2017
Resolved
Tighten main diesel engine motor mounts (mounts to stringers), port & starboard sides.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 26 April 2017
Resolution: Attending Inspector verified adjustments made to main engine mounts (Port/Starboard).
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2017
Resolved
Provide electrical one line diagram (DC) and load analysis (DC) for newly installed/rewired system (DC). *Submit to MSC for review/approval.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 8 May 2024
Resolution: Approved Electrical One-Line Diagram Letter E2-2401770 was received from MSC and verified on the vessel.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Condition
Issued 31 March 2017
Resolved
Troubleshoot pre-engineered fire suppression system with regards to main engine shutdown(s).
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 31 March 2017
Resolution: Attending Inspector performed an operational test of vessels pre-engineered fire suppression system to ensure main engine shut down upon activiation. Test sat.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 23 February 2017
Resolved
Vessel not equipped with proper qty of visual distress signals for prescribed route.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 31 March 2017
Resolution: Attending Inspectors verified carriage of propery type/qty of visual distress signals for vessels route.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 23 February 2017
Resolved
Vessels ventilation closure for the machinery space in way of starboard main deck was fractured/required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 31 March 2017
Resolution: Attending Inspector verified closure modifications made to machinery space ventilation closure device. Performed operational test, test sat.
Engineering › Bilge Water Management System › Hose
Issued 23 February 2017
Resolved
Repair/replace fwd engine room/battery compartment bilge discharge hose (collapsed/kinked)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 31 March 2017
Resolution: Attending Inspector verified hose replacement in way of fwd engine room/battery compartment.
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 February 2017
Resolved
Repair/replace raw water valve (thru-hull) for raw water washdown pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 31 March 2017
Resolution: Attending Inspector verified replacement of thru-hull valve for raw water washdown pump. Performed operational test, test sat.
Engineering › Steering Gear System › Interlock
Issued 21 October 2014
Resolved
The hollow rod connecting the two rudder stocks and the steering ram broke into two pieces on the rod itself starboard of the bracket for the steering ram connection.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 October 2014
Resolved 21 October 2014
Resolution: The hollow rod was removed and a solid piece of stainless steel was inserted inside the rod and tack welded. The two rod pieces were then welded together, making a more solid rod and was reinstalled onto the steering system.
Engineering › Fuel Oil Service System › Piping
Issued 11 June 2012
Resolved
Metal fuel piping on port fuel tank leading to port main engine ruptured
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2012
Resolved 11 June 2012
Resolution: Hard pipe fitting installed in fuel tank and flexible fuel line installed IAC SAE J1942.
Lifesaving › Lifeboat Equipment › Oar
Issued 14 August 2011
Resolved
Oars missing from life float. Replace oars.
Action required: 705 - Other - as specified
Resolved 14 August 2011
Resolution: Oars were replaced.
Lifesaving › Lifefloat › Lifeline
Issued 11 August 2011
Resolved
Replace lifelines and properly attach to lifefloat, lightbuoy and float free link.
Action required: 705 - Other - as specified
Resolved 14 August 2011
Resolution: Lifelines were replaced and properly attached to the lifefloat, lightbuoy and float free link.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 August 2011
Resolved
Prove proper illumination of the compass light.
Action required: 705 - Other - as specified
Resolved 14 August 2011
Resolution: Compass light rewired and functioning correctly.
Documentation › Logs/Records › Logbook (official)
Issued 11 August 2011
Resolved
Missing ships logs, maintenance logs, etc.
Action required: 705 - Other - as specified
Resolved 14 August 2011
Resolution: Logs purchased, and entries started.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 11 August 2011
Resolved
Prove the master has a FCC operators permit
Action required: 705 - Other - as specified
Resolved 14 August 2011
Resolution: Application to FCC for operator replacement license sent.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2011
Resolved
Prove enrollment of master in DAPI program
Action required: 705 - Other - as specified
Resolved 14 August 2011
Resolution: Master enrolled in DAPI program. Urinalysis test administered on 12AUG11.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2011
Resolved
Vessel prohibited from night time operations due to missing navigational lights (not under command, restricted in ability to manuever).
Action required: 705 - Other - as specified
Resolved 11 August 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 5 February 2009
Resolved
Recharge fire extinguisher in foward space.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Fire extinguisher in forward space recharged.
Documentation › Logs/Records › Logbook (official)
Issued 5 February 2009
Resolved
Provide vessel log book.
Condition: Unknown
Due 19 February 2009
Resolved 19 February 2009
Resolution: Log book provided.
Engineering › Bilge Water Management System › Not Installed
Issued 5 February 2009
Resolved
Permanently install bilge pumps.
Condition: Improper Installation
Due 19 February 2009
Resolved 19 February 2009
Resolution: Bilge pumps permanently installed.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 February 2009
Resolved
Provide Rules of the Road.
Condition: Unknown
Due 19 February 2009
Resolved 19 February 2009
Resolution: Navigation rules provided.
Engineering › Freshwater Generation System › Piping
Issued 5 February 2009
Resolved
Provide metal hanger for engine room water pipe.
Condition: Improper Installation
Due 19 February 2009
Resolved 19 February 2009
Resolution: Metal hanger for engine room water pipe provided.
Engineering › Fuel Oil Service System › Piping
Issued 5 February 2009
Resolved
Replace fuel return lines.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Fuel return lines replaced.
Engineering › Lubricating Oil Service System › Filter
Issued 5 February 2009
Resolved
Repair oil filter leak.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Oil filter leak repaired.
Engineering › Fuel Oil Service System › Piping
Issued 5 February 2009
Resolved
Tighten starboard fuel line clamp on injector fuel line.
Condition: Improper Installation
Due 19 February 2009
Resolved 19 February 2009
Resolution: Starboard fuel line clamp on injector fuel line tightened.
Communications › Audible Communications › Horn/Whistle
Issued 5 February 2009
Resolved
Prove proper operation of signal horn.
Condition: Unknown
Due 19 February 2009
Resolved 19 February 2009
Resolution: Signal horn tested and proven operational.
Lifesaving › Hand Flares › Expired
Issued 5 February 2009
Resolved
Replace 01 expired flare.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Expired flare replaced.
Engineering › Freshwater System (injector cooling) › Piping
Issued 5 February 2009
Resolved
Change wasted piping on starboard turbo.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Wasted piping on starboard turbo replaced.
Lifesaving › Liferaft Equipment › Paddle
Issued 5 February 2009
Resolved
Paint paddles international orange and stencil the vessel name on them.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Paddles painted international orange and name stencilled on them.
Lifesaving › Lifeboat › Markings
Issued 5 February 2009
Resolved
Stencil vessel name on liferafts.
Condition: Improper/Lack of Maintenance
Due 19 February 2009
Resolved 19 February 2009
Resolution: Vessel name stencilled on liferafts.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 February 2009
Resolved
Visibly post all pages of Certificate of Inspection.
Condition: Improper Installation
Due 19 February 2009
Resolved 19 February 2009
Resolution: All pages of Certificate of Inspection visibly posted.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 February 2009
Resolved
Conduct satisfactory man overboard drill.
Condition: Unknown
Due 19 February 2009
Resolved 19 February 2009
Resolution: Man overboard drill satisfactorily conducted.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 February 2009
Resolved
Provide steps for emergency exit.
Condition: Unknown
Due 19 February 2009
Resolved 19 February 2009
Resolution: Steps provided for emergency exit.
Engineering › Fuel Oil Service System › Valve
Issued 9 June 2008
Resolved
Provide heat guard for fuel shutoffs
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Engineering › Steering Gear System › Bracket/Clamp
Issued 9 June 2008
Resolved
Provide metal clamps for aft space hoses.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Navigation › Piloting/Steering › Marine Charts
Issued 9 June 2008
Resolved
Provide nautical charts, light list, tides and currents publications.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 9 June 2008
Resolved
Provide approved weak links for buoyant apparatus
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Lifesaving › Buoyant Apparatus › Lifeline
Issued 9 June 2008
Resolved
Properly install port side buoyant apparatus painter line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 9 June 2008
Resolved
Make necessary repairs to collision bulkhead and forward void and deck area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 9 June 2008
Resolved
Repair or replace overhead hand rail under canopy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2008
Construction/Loadline › Hull › Bottom Plating
Issued 17 October 2007
Resolved
After removal of aft platform and deck make internal structure and plating available for inspection.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: All fantail and stern plating examination SAT.
Construction/Loadline › Hull › Bottom Plating
Issued 17 October 2007
Resolved
Properly repair (04) blisters on side shell.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: All blisters repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 October 2007
Resolved
Properly repair all damaged railing and aft platform as new.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: All repaired and installed SAT.
Construction/Loadline › Structures › Deck Plating
Issued 17 October 2007
Resolved
During replacement of decking replace all frame members in kind (4X4 w/ 4X4).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: All structures replaced SAT.
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 October 2007
Resolved
Raise coaming on engine hatch to 12" minimum.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: Engine space completely sealed off with aluminum deck plating.
Engineering › Steering Gear System › Rudder
Issued 17 October 2007
Resolved
Properly adjust or replace rudder pakcings.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: Packings adjusted SAT.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 May 2007
Resolved
Properly adjust port emergency fuel shutoff valve cable
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Cable properly adjusted.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 7 May 2007
Resolved
Replace retro-reflective tape on B.A.'s
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Retro tape replaced.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 7 May 2007
Resolved
Properly repair cracks in B.A. shells
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Cracks properly repaired
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 May 2007
Resolved
Prove proper operation of B.A. waterlights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Waterlights operational.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 May 2007
Resolved
Prove proper operation of aft bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: High water alarms functioning properly
Engineering › Steering Gear System › Ram
Issued 7 May 2007
Resolved
Properly secure steering ram anchor point.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Steering ram anchor point reinforced and secured.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2007
Resolved
Replace expired first aide items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: New first aide items provided.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 May 2007
Resolved
Provide 02 hand lanterns/flashlights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Flashlights provided.
Engineering › Bilge Water Management System › Pump
Issued 5 September 2006
Resolved
Prove proper operation of all vessels bilge pumps and high water alarms.
Condition: Improper/Lack of Maintenance
Due 5 September 2006
Resolved 5 September 2006
Resolution: securely installed all pumps and alarms.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 5 September 2006
Resolved
Ensure Buoyant apparatus are stowed in accordance with 46 CFR 180.37
Condition: Improper Installation
Due 5 September 2006
Resolved 5 September 2006
Resolution: Correctly installed all BA''s
Construction/Loadline › Hull › Stringer
Issued 5 September 2006
Resolved
Repair/replace mounting hardware on deck stringers throughout engine room.
Condition: Improper/Lack of Maintenance
Due 5 September 2006
Resolved 5 September 2006
Resolution: Installed new hardware on deck stringers
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 September 2006
Resolved
provide a second flashlight.
Condition: Unknown
Due 5 September 2006
Resolved 5 September 2006
Resolution: Purchased new flashlight.
Communications › Audible Communications › Horn/Whistle
Issued 5 September 2006
Resolved
Provide horn for the vessel.
Condition: Unknown
Due 5 September 2006
Resolved 5 September 2006
Resolution: Purchased new horn.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 September 2006
Resolved
Ensure deck rails are secure aft (port/stbd)
Condition: Improper/Lack of Maintenance
Due 5 September 2006
Resolved 5 September 2006
Resolution: Tightened rails.
Engineering › Diesel Engine (propulsion-electric) › Crosshead Assembly
Issued 5 September 2006
Resolved
Repair stbd raw water pump
Condition: Improper/Lack of Maintenance
Due 5 September 2006
Resolved 5 September 2006
Resolution: Replaced stbd. raw water pump.
Fire Fighting › Fire Bucket › Quantity
Issued 5 September 2006
Resolved
Provide 3 fire buckets for vessel.
Condition: Unknown
Due 5 September 2006
Resolved 5 September 2006
Resolution: Purchased new fire buckets.
Construction/Loadline › Hull › Side Shell
Issued 7 February 2006
Resolved
Grind port side blister
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Ground away blister.
Construction/Loadline › Hull › Weld
Issued 7 February 2006
Resolved
Recaulk 3 spots on port/ stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Recaulked necessary spots.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 February 2006
Resolved
Repair port side wooden rail piece.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Applied fiberglass over crack.
Engineering › Steering Gear System › Rudder
Issued 7 February 2006
Resolved
Rekey both rudder post arms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Both rekeyed.
Engineering › Steering Gear System › Ram
Issued 7 February 2006
Resolved
Repair hydraulic ram
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Satisfactorily repaired ram.
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 February 2006
Resolved
Seal old Gen exhaust port in aft watertight bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Sealed satisfactorily.
Engineering › Steering Gear System › Rudder
Issued 7 February 2006
Resolved
Repack both rudder posts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Repacked both posts.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 7 February 2006
Resolved
Replace port throttle cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed new cable.
Stability › Watertight Integrity › General
Issued 7 February 2006
Resolved
Repair fiberglass on port exhaust thru hole.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed new fiberglass.
Construction/Loadline › Hull › Stringer
Issued 7 February 2006
Resolved
Replace 2 wooden vertical supports, and 1 long deck support aft of engine room hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed new supports.
Stability › Watertight Integrity › General
Issued 7 February 2006
Resolved
Seal thru holes in forward engine room overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed cover for thru holes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 February 2006
Resolved
Remove all dead end wiring from the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Removed all loose wiring.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 February 2006
Resolved
Replace handle on forepeak hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed new handle.
Construction/Loadline › Hull › Keel
Issued 7 February 2006
Resolved
Properly repair cracks in forepeak keel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed new fiberglass in forepeak.
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2006
Resolved
Repair crack in collision bulkhead (lower, stbd.)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 February 2006
Resolution: Installed new fiberglass over crack.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 29 August 2005
Resolved
Port side raw water strainer has a small continuous leak.
Condition: Improper/Lack of Maintenance
Due 11 September 2005
Resolved 15 September 2005
Resolution: Repaired strainer, no more leaking.
Electrical › Lighting (service) › Outlet Box
Issued 29 August 2005
Resolved
Remove household lightbulb and outlet box from engine room.
Condition: Improper Installation
Due 11 September 2005
Resolved 15 September 2005
Resolution: Lightbulb removed, outlet box dewired and sealed off.
Engineering › Generator (propulsion-electric) › Battery
Issued 29 August 2005
Resolved
Clean or replace battery terminals.
Condition: Improper/Lack of Maintenance
Due 11 September 2005
Resolved 15 September 2005
Resolution: Battery terminals replaced.
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 August 2005
Resolved
Valve to removed generator needs to be sealed off or removed.
Condition: Improper Installation
Due 11 September 2005
Resolved 15 September 2005
Resolution: Valve has been capped off.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 August 2005
Resolved
Provide a gasket seal for both engine room hatches.
Condition: Improper/Lack of Maintenance
Due 11 September 2005
Resolved 15 September 2005
Resolution: Gasket seals installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 August 2005
Resolved
Repair port side handrails.
Condition: Improper/Lack of Maintenance
Due 11 September 2005
Resolved 15 September 2005
Resolution: Secured handrails with new brackets.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 August 2005
Resolved
Provide non combustible trash receptacle.
Condition: Improper Installation
Due 11 September 2005
Resolved 15 September 2005
Resolution: 2 metal trash receptacles on board.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 August 2005
Resolved
secure pump station on msd discharge valve
Condition: Placed in Improper Service
Due 11 September 2005
Resolved 15 September 2005
Resolution: Secured discharge valve with lock and chain.
Stability › Watertight Integrity › General
Issued 29 August 2005
Resolved
seal all watertight bulkheads.
Condition: Design Flaw
Due 11 September 2005
Resolved 15 September 2005
Resolution: Sealed all througholes with 5200 compound.
Stability › Watertight Integrity › General
Issued 29 October 2004
Resolved
Auto float switch inoperable on fwd E/R bilge pump.
Due 12 November 2004
Resolved 5 November 2004
Resolution: Float replaced and tested - all sat.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 29 October 2004
Resolved
Vent cover on top of pilot house not sealing.
Due 12 November 2004
Resolved 5 November 2004
Resolution: Made new cover for vent - all sat.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 October 2004
Resolved
Deckhand couldn't provide DAPI information.
Due 12 November 2004
Resolved 5 November 2004
Resolution: Enrollement complete.
Fire Fighting › Fire Bucket › Availability
Issued 29 October 2004
Resolved
Firebuckets missing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2004
Resolution: Provided firebuckets.
Construction/Loadline › Hull
Issued 8 December 2003
Resolved
Keel fwd aft to about the 30% area wasted. LEGACY COMPONENT DESC: Keel
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 December 2003
Resolved
F/O line on stbd main supply from filter LEGACY COMPONENT DESC: Fuel hose
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Construction/Loadline › Structures
Issued 8 December 2003
Resolved
Straps on deck beams that connect to bottom stringers wasted. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Construction/Loadline › Structures
Issued 8 December 2003
Resolved
Deck stringer in gen room near hatch wasted to 50% thickness. LEGACY COMPONENT DESC: Deck stringer
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Engineering › Shafting/Propeller Arrangements
Issued 8 December 2003
Resolved
Port aft cutlass bearing LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Engineering › Shafting/Propeller Arrangements
Issued 8 December 2003
Resolved
Port aft bearing appears to be bound causing wear on shaft. LEGACY COMPONENT DESC: Propeller Shaft
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Engineering › Steering Gear System
Issued 8 December 2003
Resolved
Packing in port rudder shaft housing worn. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2004
Resolution: See narrative
Operations/Management › Drug and Alcohol Testing
Issued 6 August 2003
Resolved
Provide drug and alcohol MRO statements. LEGACY COMPONENT DESC: Employee Coverage
Due 11 August 2003
Resolved 11 August 2003
Documentation › Logs/Records
Issued 30 July 2003
Resolved
Update waste management plans. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 11 August 2003
Resolved 11 August 2003
Lifesaving › Lifeboat Equipment
Issued 30 July 2003
Resolved
Renew six (6) oars. LEGACY COMPONENT DESC: Oar
Due 11 August 2003
Resolved 11 August 2003
Operations/Management › Navigation Safety
Issued 30 July 2003
Resolved
Provide chart of local area. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 11 August 2003
Resolved 11 August 2003
Operations/Management › Drills/Instruction
Issued 30 July 2003
Resolved
Missing emergency broadcast placard. LEGACY COMPONENT DESC: Safety Orientation
Due 11 August 2003
Resolved 6 August 2003
Communications › Radio Communications
Issued 30 July 2003
Resolved
Update EPRIB registration. LEGACY COMPONENT DESC: EPIRB
Due 11 August 2003
Resolved 11 August 2003
Communications › Audible Communications › Horn/Whistle
Issued 21 May 2002
Resolved
Portable horn inoperable.
Condition: Unknown
Due 21 May 2002
Resolved 21 May 2002
Resolution: Replaced horn.
Lifesaving › Hand Flares › Condition
Issued 21 May 2002
Resolved
Flares expired.
Condition: Unknown
Due 21 May 2002
Resolved 21 May 2002
Resolution: Replaced flares.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 May 2002
Resolved
Condition: Unknown
Due 21 May 2002
Resolved 21 May 2002
Resolution: Stenciled exit.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 May 2002
Resolved
Condition: Unknown
Due 21 May 2002
Resolved 21 May 2002
Resolution: Painted name and port on lifebuoy.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 February 2002
Resolved
Remove un-used fixed firefighting system in old generator compartment. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 7 March 2002
Resolved 7 March 2002
Resolution: items removed.
Electrical › Electrical Distribution System (service)
Issued 15 February 2002
Resolved
Remove all dead end wiring in hull and old generator compartment. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 7 March 2002
Resolved 7 March 2002
Resolution: All loss wires removed.
Construction/Loadline › Hull
Issued 15 February 2002
Resolved
Repair fiberglass on both sides of stiffener just forward of the main engines midship. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Due 7 March 2002
Resolved 7 March 2002
Resolution: corrected.
Construction/Loadline › Hull
Issued 15 February 2002
Resolved
Repair fiberglass on collision bulkhead under stbd seat in fwd compartment. LEGACY COMPONENT DESC: Stiffener
Condition: Improper Installation
Due 7 March 2002
Resolved 7 March 2002
Resolution: Area fiberglass repaired satisfactory
Construction/Loadline › Structures
Issued 15 February 2002
Resolved
Make forward water-tight deck access hatch to chain locker watertight. LEGACY COMPONENT DESC: Manhole
Condition: Damaged By Earlier Event
Due 7 March 2002
Resolved 7 March 2002
Resolution: Corrected.
Documentation
Issued 10 September 2001
Resolved
PROVIDE PROOF OF DRUG AND ALCOHOL PROGRAM ENROLLMENT.
Condition: Unknown
Due 16 September 2001
Resolved 16 September 2001
Lifesaving
Issued 10 September 2001
Resolved
PROVIDE PROOF OF CPR/FIRST AID.
Condition: Unknown
Due 16 September 2001
Resolved 16 September 2001
Fire Fighting
Issued 10 September 2001
Resolved
PROVIDE LANYARDS ON FIREBUCKETS AND STENCIL "FIREBUCKET."
Condition: Unknown
Due 16 September 2001
Resolved 16 September 2001
Navigation
Issued 22 September 2000
Resolved
MAKE PROPER REPAIRS TO THE MAIN STEERING HYDRAULIC RAM MOUNTING BRACKET.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Electrical
Issued 27 July 1999
Resolved
Repair or replace all interior lights.
Condition: Unknown
Due 10 August 1999
Resolved 19 August 1999
Documentation
Issued 27 July 1999
Resolved
OBTAIN AN FCC MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Lifesaving
Issued 27 July 1999
Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 10 August 1999
Resolved 19 August 1999
Fire Fighting
Issued 27 July 1999
Resolved
SERVICE ALL FIRE EXTINGUISHERS AND FIXED FF SYSTEM.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Fire Fighting
Issued 27 July 1999
Resolved
OBTAIN TWO TYPE B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Lifesaving
Issued 27 July 1999
Resolved
REPLACE ALL LIGHTS ON LIFEJACKETS.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Documentation
Issued 27 July 1999
Resolved
Obtain Coast Pilot for vessel.
Condition: Unknown
Due 10 August 1999
Resolved 19 August 1999
Fire Fighting
Issued 27 July 1999
Resolved
PROVIDE CERTIFICATION OF PROPER INSTALLATION AND OPERATION OF FIRE EXTINGUISHING SYSTEM IAW 46 CFR 181.420.
Condition: Unknown
Due 10 August 1999
Resolved 19 August 1999
Documentation
Issued 27 July 1999
Resolved
POST COPY OF VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Construction/Loadline
Issued 27 July 1999
Resolved
INSTALL AUDIBLE ALARM ON BILGE HIGH-LEVEL ALARMS.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Fire Fighting
Issued 27 July 1999
Resolved
INSTALL AUDIBLE AND VISUAL ALARMS FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Fire Fighting
Issued 27 July 1999
Resolved
INSTALL MANUAL ACTUATION SYSTEM OUTSIDE OF ENGINE ROOM FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Lifesaving
Issued 27 July 1999
Resolved
MAKE NECESARY REPAIRS TO LIFE FLOAT, INCLUDING REPLACEMENT OF PADDLES.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Documentation
Issued 10 August 1998
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Documentation
Issued 10 August 1998
Resolved
PROVIDE WASTE MGT. PLAN IAW 33CFR151.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Engineering
Issued 10 August 1998
Resolved
REPAIR LEAKY FUEL VALVE.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Engineering
Issued 10 August 1998
Resolved
PROPERLY MARK AND PROVE PROPER OPERATION OF EMERGENCY FUEL CUT OFF VALVE IAW 46CFR185.30-20 AND 46CFR182.20-40(B).
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Electrical
Issued 10 August 1998
Resolved
PROPERLY SUPPORT WIRES WITH METAL RETAINERS.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Navigation
Issued 10 August 1998
Resolved
PROVE PROPER OPERATION TO SINGLE SIDE BAND RADIO. VESSEL TO OPERATE IN RANGE OF VHF.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Construction/Loadline
Issued 10 August 1998
Resolved
PROVE PROPER OPERATION OF BILGE ALARMS.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Construction/Loadline
Issued 10 August 1998
Resolved
GRIND AND REGLASS FRACTURE AT TRANSOM.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Navigation
Issued 10 August 1998
Resolved
REPAIR FRACTURED STBD RUDDER POST SUPPORT.
Condition: Unknown
Due 17 August 1998
Resolved 19 August 1998
Construction/Loadline
Issued 10 August 1998
Resolved
REPAIR BROKEN DOG TO FWD HATCH COVER.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Electrical
Issued 26 May 1998
Resolved
PROVE PROPER OPERATION OF NEW GENERATOR.
Condition: Unknown
Due 26 May 1998
Resolved 26 May 1998
Navigation
Issued 26 May 1998
Resolved
REPLACE DAMAGED SPOTLIGHT.
Condition: Unknown
Due 26 May 1998
Resolved 26 May 1998
Accommodation/Occupational Safety
Issued 26 May 1998
Resolved
REPLACE HANDLE ON THE HEAD DOOR.
Condition: Unknown
Due 26 May 1998
Resolved 26 May 1998
Construction/Loadline
Issued 26 May 1998
Resolved
PROVIDE DOGS/LATCHES TO MAKE ENGINE ROOM HATCH COVER WATERTIGHT.
Condition: Unknown
Due 26 May 1998
Resolved 26 May 1998
Construction/Loadline
Issued 5 March 1998
Resolved
INCREASE HEIGHT OF ENGINE COMPARTMENT HATCH COAMING TO 12 INCHES.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Construction/Loadline
Issued 5 March 1998
Resolved
REPAIR DELAMINATED TAB ON PORT ENGINE STRINGER LATERAL STIFFENER.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Construction/Loadline
Issued 5 March 1998
Resolved
REPAIR DAMAGED AND DELAMINATED BOTTOM STIFFENER ON STBD SIDE OF GENERATOR COMPARTMENT.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Accommodation/Occupational Safety
Issued 5 March 1998
Resolved
REPAIR DELAMINATED SECTION OF PORT CATWALK.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 23 July 1997
Resolved
REPLACE BURNED OUT SPOTLIGHT BULB.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 23 July 1997
Resolved
PROVIDE PROPERLY LABELLED WEAK LINK FOR THE LIFEFLOAT.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Documentation
Issued 23 July 1997
Resolved
UPDATE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 23 July 1997
Resolved
RESTENCIL FADED VESSEL NAME ON LIFEFLOAT.
Condition: Unknown
Due 23 August 1997
Resolved 23 July 1997
Electrical
Issued 23 July 1997
Resolved
REMOVE UNUSED LORAN C ANTENNA WIRE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Navigation
Issued 18 July 1996
Resolved
REPAIR/REPLACE SPARE LORAN C COUPLER.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Documentation
Issued 18 July 1996
Resolved
PROVIDE ELECTRICAL AND MACHINERY PLANS FOR REVIEW.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Navigation
Issued 18 July 1996
Resolved
REPLACE SPARE VHF-FM RADIO POWER CABLE.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996