Records from 2011 to 2026. Most recent: inspection, 20 April 2026.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 April 2026
Resolved
A hatch exposed to the weather must be watertight. The gaskets for the scuttles to the forepeak, #2 void, the engine room, and the lazarette are deteriorated and ineffective, the closures cannot be made watertight.
46 CFR 179.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2026
Resolved 8 June 2026
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2025
Resolved
Fire hoses must be of commercial grade and conform with UL 19 standards; the outer jacket of the port fire hose is deteriorated and must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2025
Resolved 8 June 2026
Resolution: Verified corrected
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 June 2025
Resolved
The marine employer must have a drug testing program in place. The captain could not provide proof of contract, the list of employees, or the current MIS report.
46 CFR 16.113
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 20 November 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 June 2025
Resolved
The marine employer must have a drug testing program in place. The alcohol saliva test swabs are expired.
46 CFR Part 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 20 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two adult life jackets were condemned during the inspection, the master provided two new jackets at the end of the inspection.
46 CFR 180.071
Action required: 10 - Deficiency Rectified
Due 27 June 2025
Resolved 13 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 June 2025
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. The life floats were not so marked.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 20 November 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 June 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in ISO 18813 or a kit with equivalent contents. The existing kit does not include burn preparations, provide vessel with 12 applications of burn preparations.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2025
Resolved 20 November 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 November 2024
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with § 181.425. The galley griddle hood is not in compliance with 181.425, does not have fixed fire fighting capability and must meet UL 710. The vessel is no longer allowed to use cooking appliance until an approved grease extraction hood has been installed in accordance with USCG approved plans.
IAW 46 CFR 181.405 (b)
Action required: 705 - Other - as specified
Resolved 13 June 2025
Resolution: UL approved system installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 October 2024
Resolved
A self priming, power driven fire pump must be installed on each vessel Of not than 19.8 meters (65 feet) in length that carries more than 49 passengers; vessel's firepump is leaking water from packing but is still functional.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 22 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2024
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom; vessel 02 plastic trashcans.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 22 November 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024
Resolved
Replace plastic wire hangers in overhead of ER w/ a suitable hanger resistant to fire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 30 April 2024
Resolution: Stainless Steel zip ties were added
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 April 2024
Resolved
Person in command of a documented vessel must have onboard the original Certificate of Documentation onboard; vessel has valid COD but document is not onboard. 46 CFR 67.313
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 30 April 2024
Resolution: Original COD placed onboard
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 April 2024
Resolved
On a vessel of at least 26 ft in length and visual and audio=ble alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces; a machinery space bilge; loose wire renders alarm inoperable
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 2 May 2024
Resolution: Wire conection re-terminated
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; # 18 breaker in galley panel has two conductors attached.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 30 April 2024
Resolution: Extra circuit breaker added
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2024
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with § 181.425. galley griddle hood is not in compliance with 181.425 and does not have fixed fire fighting capability and must demonstrate compliance w/ UL 117. Owner must submit plan for repair w/in 30 days and must have repair completed w/in 6 months
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 November 2024
Resolved 20 November 2024
Resolution: This CG-835 is not resolved, however, it has been updated. A more restrictive CG-835 has been issued under activity #8037747.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation; valve is not labled
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 2 May 2024
Resolution: Shut-off re-labled
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2024
Resolved
On a vessel operating on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless the sill of the port light is at least 760 millimeters (30 inches) above the deepest load waterline; Plug or valve pipe in side shell in lazarette
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 30 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 January 2024
Resolved
The engine compartment escape hatch is not operational; repair and prove watertight integrity.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 6 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 October 2023
Resolved
A vessel must have an interconnected fire/smoke detection system in all accommodation spaces. The smoke detectors in the passenger accommodation space are either missing or rendered inoperative.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 April 2023
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle; the existing marking have faded and are no longer legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 24 May 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 April 2023
Resolved
All escape hatches and other emergency exits must be marked "EMRGENCY EXIT, KEEP CLEAR" on both sides; the engine compartment escape hatch is not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 24 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 April 2023
Resolved
The construction and arrangements of the vessel must allow for safe operations giving consideration to the seaworthiness of the hull; two main support structures (stanchions) in the #1 void have broken welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2023
Resolved 7 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2023
Resolved
At each inspection of a vessel the operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems; the spot light is not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2023
Resolved 30 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2022
Resolved
The vessel must be provided with a satisfactory arrangement for draining any watertight compartment in accordance with 46 CFR 182.500; the bilge manifold is holed due to corrosion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2022
Resolution: Cracked pipe nipple was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2022
Resolved
The vessel must be provided with a satisfactory arrangement for draining any watertight compartment in accordance with 46 CFR 182.500; the installed hoses IWO the bilge manifold are deteriorated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2022
Resolution: Hoses replaced and fastened using two hose calmps on each end
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2022
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment in accordance with 46 CFR 182.455(b)(6); the installed Racor filters have excessive build-up of water and require cleaning and replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2022
Resolution: Both racors were replaced and bowls cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2022
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray in accordance with 46 CFR 183.350; the generator start batteries are not protected against shifting and are sitting in water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2022
Resolved 6 October 2022
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 22 September 2022
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition in accordance with 46 CFR 176.818; the toilet drain pipes are holed and leaking into the engine compartment, submit a repair proposal and make repairs to the satisfaction of an attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2022
Resolved 4 October 2023
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 June 2022
Resolved
Each vessel subject to 46 CFR Part 178, Subpart C must, in each condition of loading and operation, comply with the applicable requirements of 46 CFR Part 170; weight changes due to modifications/alterations have occurred over the years affecting the vessels lightship characteristics, including but not limited to the replacement of both main engines, replacement of the generator with prime mover, replacement of the A/C unit on the upper deck, and the modification to the chine in which approximately 535 pounds of aluminum angle was added. Accordingly, the operator must submit calculations to the Marine Safety Center for determination if a dead-weight survey, or a full stability test is required to demonstrate compliance with the pertinent regulations and confirm the validity of the vessel's stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 27 July 2023
Resolution: New stability letter issued by the MSC.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 March 2022
Resolved
A fire pump on a TL vessel shall be able to discharge 50 gpm @ 60 psi; vessel's gauge was only puting out 30 psi.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2022
Resolved
The shorepower breaker must be interlocked w/ the vessel's gen breaker; current interlock bar does not prevent both breakers from being closed at the same time
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2022
Resolved
Circuits in panels must be labeled; Switchboard aand galley breaker panel are not labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 27 April 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2022
Resolved
Employers must ensure that they and their crewmembers meet the requirements of part 16; vessel does not have required documentation for employees or training; a full company audit is to be conducted w/in 30 days
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 May 2021
Resolved
Any vessel of at least 5 net tons which engages in commercial service must have a Certificate of Documentation; the certificate on board is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 May 2021
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date charts and navigation publications; the existing chart is out dated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 May 2021
Resolved
A manned oceangoing vessel of 40 feet or more in length engaged in commerce must have a garbage management plan; the person in charge listed on the existing plan is no longer employed on board, the plan is out dated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 10 May 2021
Resolved
In accordance with 47 CFR Subpart S Small Passenger Vessels operating beyond 20 nautical miles but not more than 100 nautical miles from the nearest land must be equipped with a MF-DSC radio; the captain is not able to prove that the single side band radio is operational. The vessel is restricted to less than 20 NM from land.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 20 May 2024
Resolution: Vessel receeived Sat phone exemption
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 May 2021
Resolved
Gauges to indicate engine lube oil pressure must be provided for all propulsion engines, the gauges must be readily visible at the operating station; the lube oil gauge for the port engine is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021
Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; there is an electrical box under the operating station console which is missing the cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 May 2021
Resolved
Each life float approved under 46 CFR 160.027 must meet the requirements of 160.010 in which the pendants must be fitted approximately 18" apart, around the outside of the float, and must be at least 1/4" diameter and 12' long, secured in the middle; the existing pendants are deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021
Resolved
A vessel of more than 65’ in length must carry a minimum of three life buoys; the port side life buoy is deteriorated and reaching the end of its service life.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; the existing kit is not an approved type and does not appear to have the proper inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 May 2021
Resolved
A hatch exposed to the weather must be watertight; the hatch to the #1 void does not seal properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 15 February 2022
Resolution: Hatch was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 May 2021
Resolved
Where flexible non-metallic piping (hose) is permitted in piping systems it must meet the required specifications for its intended purpose and be otherwise acceptable to the OCMI; the hose on the suction side of the mechanical bilge pump IWO the stbd engine is deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 April 2021
Resolved
At each inspection, the owner/ operator shall be prepared to conduct test operations of machinery to include machinery essential to teh routine operation of the vessel including generators; the generator prime mover has a severe jacket water leak at the pump and the pump bearings are worn.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2021
Resolved 30 April 2021
Resolution: Techs replaced water pump and MI witnessed proper operation of generator.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 April 2021
Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10; the annual service has not been conducted and is overdue, additionaly, one extinguisher indicates no pressure on the gauge and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2021
Resolved
At each inspection for certification of a vessel the managing operator shall be prepared to conduct tests to prove the hull structures and appurtenances are sound, including through hull fittings and valves; the sewage discharge pipe is holed between the through hull penetration and the sea valve allowing water ingress. Temporary repairs are in place to allow the vessel to transit to drydock for permanent repairs to be carried out.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 June 2020
Resolved
The master of the vessel shall ensure that the EPIRB battery is replaced prior to its expiration date; the existing battery expired in May 2020.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2020
Resolved
Exhaust pipe shall be gastight throughout its length; the port main engine exhaust pipe is holed and is leaking cooling water into the engine compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 June 2020
Resolved
Bilges shall be kept free of excessive water so as to avoid an unsafe condition; the #1 and #2 void compartments have excessive water in the bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 June 2020
Resolved
A hatch exposed to the weather must be watertight; several manhole covers are leaking due to poor maintenance, and water is accumulating in the bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2020
Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; the distribution panel in the galley and the engine room have openings which require blank covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2020
Resolved
Where flexible non-metallic piping (hose) is permitted in piping systems it must meet the required specifications for its intended purpose and be otherwise acceptable to the OCMI; the lube oil hose for the stbd transmission is deteriorated and no longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2020
Resolved
The name of the vessel must be marked in clearly legible letters on each piece of lifesaving equipment; the marking on the lifebuoys and the life float paddles are faded and not legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 June 2020
Resolved
Each life float paddle must be lashed to the float to which it belongs; the paddles are not attached to the floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 June 2020
Resolved
A vessel must carry adequate and up-to-date navigation publications for the intended route; the vessel does not have the Notice to Mariners on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 June 2020
Resolved
Vessels over 65 feet in length must have an FCC Bridge-to-Bridge Certificate issued upon satisfactory inspection; the vessel does not have a current certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 31 May 2019
Resolved
Hatches on the main deck shall be watertight. The lazerette and engine room hatch are not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
Resolution: Received phone call from vsl Capt ([name withheld]) stating that all hatches have been maintenanced and are operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019
Resolved
Vessels over 65 ft must have 3 ring buoys. The grab line on 2 of 3 is deteriorated. Replace with 24" orange CG approved.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2019
Resolution: Prior to departing the vsl new ring buoys were provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 May 2019
Resolved
All vessels shall have arrangements to pump all watertight spaces. The pipe assembly to the forepeak suction is inoperable. The valve and strainer need to be re-thread.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2019
Resolution: Photo and verbal communication received to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 May 2019
Resolved
Vsl shall be provided with appropriate navigation publications. Provide excerpts of updated coast pilot and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: Appropriate updated nautical publication are onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 May 2019
Resolved
Vsl over 65 feet shall have a fire pump capable of 60 PSI at 50 GPM. Current pump is 40 psi with one hose open.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: The gauge was changed and the pump retested. A pressure of 50 psi was achieved and accepted.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 31 May 2019
Resolved
The SSB shall have two sources of power. Move the current configuration to provide a second source of power for 3 hours duration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: A jumper has been installed to provide back up power to the bus that provides power to the SSB.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Lifejackets shall have approved reflective tape. Ensure all jackets have adequate tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: Crew states that they corrected this while stowing jackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2019
Resolved
Fuel vents shall be fitted with 30 x 30 stainless mesh. Current mesh is not 30 x 30.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: Properly corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2019
Resolved
Panel boards shall have no openings. The main engine room panel is missing 2 blanks and the galley panel is missing 1.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: Properly corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 31 May 2019
Resolved
Vsl over 65 ft shall have contrasting draft marks forward and aft. The forward draft marks are not contrasting.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2019
Resolution: Owner stated he would have a crewmen hand paint draft marks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2019
Resolved
Electrical installations shall be to the satisfaction of the [name withheld] the following:
a)provide ground for battery charger case
b)label 12 volt panel in pilot house
c)provide appropriate overcurrent protection for main output from converter
d)install permenant 120 volt outlets as needed in pilot house
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: All items have been corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018
Resolved
The vessel is currently broadcasting (1) Zero Length and Beam, (2) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 12 June 2020
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 April 2018
Resolved
Provide proof of user fee payment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 14 May 2018
Engineering › Bilge Water Management System › Piping
Issued 30 April 2018
Resolved
Repair the pinhole leak in the bilge piping IWO the #1 void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 30 April 2018
Resolved
Provide new reflective tape for three jackets where deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 14 May 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 April 2018
Resolved
Ten life jackets were condemned due to the condition, provide new life jacket. The vessel is restricted to ten fewer persons until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 14 May 2018
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 April 2018
Resolved
The heat exchanger for the generator prime mover is wasted and leaking, replace heat exchanger.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 14 May 2018
Engineering › Fuel Oil Service System › Hose
Issued 30 April 2018
Resolved
Replace two fuel hoses on the port main engine due to deterioration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 14 May 2018
Engineering › Bilge Water Management System › Pump
Issued 17 March 2017
Resolved
STBD engine driven mechanical bilge pump was not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 20 March 2017
Resolution: New pump installed and tested.
Construction/Loadline › Penetrations › Pipe Flange
Issued 17 March 2017
Resolved
Small crack on port MDE raw water sea suction pipe at through hull weld allowing water to leak into bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 April 2017
Resolution: Weldment has been placed over the leak. No signs of leakage at time of inspection.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2017
Resolved
Ship service generators pulley guard was loose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 April 2017
Resolution: Item satisfactorily corrected.
Engineering › Bilge Water Management System › Valve
Issued 17 March 2017
Resolved
Bilge manifold was missing a check valve for the steering gear room suction pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 April 2017
Resolution: Check valve installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 March 2017
Resolved
Port MDE raw water supply pipe to heat exchanger on inboard side was leaking sea water.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 April 2017
Resolution: Part was replaced and tested sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 March 2017
Resolved
Missing port and stbd B-II mounting bracket in main passenger cabin on main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 20 April 2017
Resolution: Appropriate mounting brackets installed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 May 2016
Resolved
Install plug in F/O tank drain (located in engine room).
Due 16 June 2016
Resolved 16 May 2016
Resolution: Prior to departure from vessel a plug was properly installed in the fuel stripping line.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 May 2016
Resolved
2 of the child size life jackets were no longer servicable.
Due 16 May 2016
Resolved 16 May 2016
Resolution: 2 child life jackets were replaced and properly marked prior to MI departure.