Records from 1984 to 2026. Most recent: inspection, 22 April 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Provide 7 additional adult Type I PFDs.
Maximum persons allowed is reduced by seven (7) to one-hundred-twenty-five (125) until new PFDs are provided.
Action required: 705 - Other - as specified
Resolved 14 April 2025
Resolution: New PFDs provided
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 March 2024
Resolved
Each survival craft required on a vessel by this part must meet one of the following: (2) For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition;
The 25 person life float installed on the vessel was no longer in serviceable condition.
Provide serviceable primary lifesaving as required per the vessels Limited Coastwise route.
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: A serviceable 22 person life float was installed on the vessel to replace the condemned 25 person life float. Vessel COI amended to reflect the new primary lifesaving capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 June 2023
Resolved
Each vessel certificated to operate on a limited coastwise oute in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board.
Vessel is restricted to a maximum number of persons onboard of 94. Total number of passengers is 91 plus 3 crew until a new life float is provided to accommodate 50% of the total number of passengers allowed by the stability letter.
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: Provided an additional serviceable 22 person life float.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2022
Resolved
For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition.
Life floats were in unusable condition due to wasted netting, straps, and lines. vessel limited 3 nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2022
Resolution: O/O had life floats repaired and placed back in service
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 April 2022
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight,A hatch in a cabin top.
Port and stbd aft windows are missing hatches that were previously installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 27 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 April 2022
Resolved
A hatch exposed to the weather must be watertight.
Fore peak and lazzerette hatches failed hose test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 27 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor.
Crew compartment fwd of E/R and laz has open dead end wire present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 22 April 2022
Resolution: Placed electrical connector on a junction box
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2022
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 22 April 2022
Resolution: Replaced with steel trash cans
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 April 2022
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
Gaff hook was used to recover MOB and attachment hardware for ladder was missing.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Vessel placed two shackles on the vessel and located the missing plastic boathook for MOB.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 April 2021
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing navigational publications were found expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 19 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2021
Resolved
Vessel required to carry current/up to date navigational charts for areas transited. Existing charts were outdated.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 19 August 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 April 2021
Resolved
Vessel required to be fitted with bilge high water alarms. Existing bilge high water alarms (#5) for lazarette was inoperable at time of testing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021
Resolved
All bulkhead penetrations shall be made watertight. Exisiting watertight bulkhead penetrations IWO fixed bilge piping were found with open communication between compartments.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 April 2021
Resolved
Watertight hatch covers are required to be marked. Existing watertight hatch covers were missing required markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 April 2021
Resolved
Vessel required to be fitted with ventilation closure devices. Existing ventilation closure devices were not properly marked to identify location of installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 January 2021
Resolved
Determine the cause of the fuel oil leak on the stbd generator IWO the #3 injector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 January 2021
Resolved
Determine the cause of the leaks associated with the raw water pumps on both port and stbd main engines and repair as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 January 2021
Resolved
Renew the CO2 system piping as necessary in the forward void/rod room due to deterioration and holes, the piping must be of proper specifications, installed and tested in accordance with 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2021
Resolution: Attending Inspector witnessed satisfactory pressure test of CO2 discharge piping.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2020
Resolved
The scope of the annual inspection is the same as the inspection for certification to ensure that the vessel is in satisfactory condition, fit for service intended, and complies with all applicable regulations. Water ingress was noted in way of machinery space chines (port/starboard), fuel tank void (port) and stem (while u/w).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2020
Resolved
Vessel required to be fitted with a ring life buoy with floating water light. Existing floating water light was found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of floating water light.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2020
Resolved
Vessel required to be fitted with life floats with floating water lights. Existing floating water lights were found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of life float lights.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2020
Resolved
Vessels life floats and associated equipment required to be marked. Existing markings for life float and paddles are worn/faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified renewal of markings for life floats and paddles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2020
Resolved
A vessel must be equipped with bilge pumps capable of draining any watertight compartment under all practicable conditions. Existing power bilge pump controls were worn/faded/non-legible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified renewal of markings/labeling for bilge pump controls.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2020
Resolved
Vessel required to be fitted with seating to minimize the possibility of injury and avoid trapping occupants. Existing hardware for fixed seating was found loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified condition of seating hardware.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 July 2020
Resolved
Vessels main deck watertight hatches are required to be marked. Existing main deck watertight hatches are not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified posting of markings for watertight hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2020
Resolved
Vessels experiences a vibration in way of port propulsion shaft at various RPM's (vibrations worsen with increase in RPM's). Shaft to be drawn for further inspection NLT 31DEC2020.
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2020
Resolved
Starboard main diesel engine low oil pressure sensor was found disconnected (following engine installation).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of oil pressure gauge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Watertight bulkhead between tank room/lazarette was found to be non-watertight in way of port side/outboard of keel where the previous repair meets up with original bulkhead. Temporary repairs are authorized until permanent repairs can be affected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 1 May 2020
Resolution: Attending Inspector(s) verified repairs to watertight bulkhead between lazarette and tank room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Water intrusion noted IWO port hull planking @ chine (outboard of port fuel tank) in tank room. Fuel tank installation impedes access to the affected area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 1 May 2020
Resolution: Attending Inspector(s) verified repairs made IWO port chine.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Water intrusion noted IWO forepeak between stem/frames 3/4. Water intrusion is only present while vessel is u/w.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 24 July 2020
Resolution: Attending Inspector cleared deficiency and re-issued via CG-835V on 24JUL2020.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2019
Resolved
Fire hose (garden hose style) requires replacement due to deterioration.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspecctor(s) verified renewal of fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2019
Resolved
Provide proper type/style of power switch for fixed bilge pump in way of machinery space.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation of proper type of switch for bilge pump.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 May 2019
Resolved
Repair ventilation closure devices/trunks in way of port & starboard side main deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified repairs/modifications made to ventilation closure devices IWO port/stbd main deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2019
Resolved
Improper fuse block installed in way of starboard machinery space @ battery bank (blade style fuses).
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation of proper type of fuse holder/block.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019
Resolved
Broken baffles in port muffler/silencer for port main diesel engine in way of tank void.
Condition: Improper/Lack of Maintenance
Due 23 May 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified replacement of port muffler assembly IWO tank room.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 23 May 2019
Resolved
Renew flexible hose connection between MSD tank (discharge) and thru-hull valve due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019
Resolved
Renew hose clamp for port main diesel engine muffler/silencer @ flex hose assembly in way of tank room.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified replacement of muffler clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 May 2019
Resolved
Provide securing device/bracket for refrigerator located in serving area (prevent movement).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of securing bracket for refrigerator in serving area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019
Resolved
Properly terminate/remove dead ended wiring in way of console/under helm.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified removal/proper termination of wiring under console/helm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019
Resolved
Limit termnals/accessories to not more than four (4) in way of starboard battery bank in machinery space.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified terminal connections to battery installations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 May 2019
Resolved
Provide current/up to date NOAA registration for vessels EPRIB.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified registration/markings for EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 May 2019
Resolved
Renew pendants in way of life floats (x3)due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified renewal of life float pendants.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019
Resolved
Renew markings for life float paddles.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified markings for life float paddles.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2019
Resolved
Repair/replace naviational lighting assemblies due to age/deterioration (lenses are frosted/oxidized) for port & starboard side lights.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation/operation of navigational lights.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 May 2019
Resolved
Provide current/up to date navigational publications for areas transited.
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified carrige of current/up to date navigational publications for areas transited.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019
Resolved
Repair life float stanchions IWO starboard life flaot arrangement (outboard).
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified repairs made to life float stanchions.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019
Resolved
Renew batteries in way of lifesaving equipment (floating water lights).
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified renewal of batteries IWO floating water lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2018
Resolved
Attending Inspector(s) identified "rot" IWO upper deck bulwark, port side, outboard of ladder. Issued requirement on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 May 2018
Resolved
Vessel did not carry current/up to date navigational publications (CG Light List, Tide Tables, Tidal Current Tables, Coast Pilot) for areas transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2018
Resolved
Electric submersible bilge pump/float switch failed to operate properly during testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector witnessed repairs made to float switch and performed satisfactory operational test.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2018
Resolved
Floating water lights for life floats not equipped with proper batteries as per manufacturers instructions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of proper battery type for floating water lights for life floats.
Lifesaving › Lifefloat › Pendant
Issued 2 May 2018
Resolved
Pendants for life floats required replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified replacement of life float pendants.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2018
Resolved
Renew line for floating water lights for lifefloat installation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified renewal of line for floating water light for life floats.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 2 May 2018
Resolved
Refrigerator not properly secured to prevent movement IWO galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of a bracket to secure regrigerator from movement IWO galley/serving area.
Stability › Watertight Integrity › General
Issued 2 May 2018
Resolved
Thru-hull valve IWO tank room not properly installed/secured/capped off.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of a cap/plug for thru-hull valve located outboard keel, port side IWO tank room.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 2 May 2018
Resolved
Ventilation piping for port & starboard fuel oil tanks were not properly installed/terminated outside of the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of fuel oil vents for port & starboard fuel tanks IWO tank room.
Engineering › Bilge Water Management System › Valve
Issued 2 May 2018
Resolved
Submersible bilge pump piping IWO tank room (stbd) not equipped with stop valve at side shell (<18" deepest load waterline).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of stop valve @ side shell IWO tank room for electric submersible bilge pump discharge hose.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 May 2018
Resolved
Exhaust flex hoses required adjustment/tightening IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of new clamps and the adjustment/tightening of existing clamps for exhaust flexible hose connections IWO lazarette.
Stability › Watertight Integrity › General
Issued 2 May 2018
Resolved
Main deck watertight hatches required servicing/adjustment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector witnessed operation of main deck watertight hatches for forepeak and lazarette.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 2 May 2018
Resolved
Service/repair/replace thru-hull valves IWO port & starboard ships service diesel generator exhaust valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified the operation of the port & starboard exhaust discharge thru-hull valves for SSDG's.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 May 2018
Resolved
Ventilation ducts along main deck (port & starboard) require repair/replacement due to deterioration. Space is protected by fixed CO2 system. Ducts serve as primary ventilation closures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO vertical transverse frames (approx. 8) along transom. All frames were marked accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2018
Resolved
Rot noted IWO main deck support beam (4th frame fwd of transom) & port side shell in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO port & starboard main deck support beams/structure in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2018
Resolved
Crop/renew deck planking @ watertight hatch for lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Repair/replace main deck beam IWO forepeak frames #1/2 where marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2018
Resolved
Crop/renew main deck planking IWO forepeak watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO forepeak side shell framing (stbd)#1/2/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO watertight bulkhead/side shell frame in forepeak (stbd).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO forepeak frames #4/7 (port).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2018
Resolved
Repair/replace hardware for transverse framing IWO forepeak where marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 May 2018
Resolved
Renew flexible shaft log boots due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2018
Resolved
Attending Inspector(s) identified "rot" IWO upper deck, starboard side ceiling (aft of pilothouse). Requirement issued on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2018
Resolved
Attending Inspector(s) identified at least three "soft spots" IWO upper deck (aft of pilothouse). Requirement issued on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2018
Resolved
Attending Inspector(s) called out rot in way of port upper deck planking IWO aft cabin bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Attending Inspector(s) verified final repairs for upper deck planking IWO aft cabin bulkhead.
Construction/Loadline › Structures › Superstructure
Issued 12 December 2017
Resolved
Repair main deck overhead/upper deck transverse beams IAW good marine practice following port main diesel engine installation.
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Attending Inspector(s) witness final repairs made to upper deck beams and planking.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 August 2017
Resolved
Port main diesel engine exhaust riser/mixer was fractured.
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 7 February 2018
Resolution: Attending Inspector(s) verified installation of port main diesel engine exhaust risers (inboard/outboard).
Stability › Watertight Integrity › General
Issued 25 August 2017
Resolved
Vessels main deck watertight hatches failed to operate/seal properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2017
Resolution: Attending Inspector verified repairs/adjustments to main deck watertight hatches and performed operational test.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 April 2017
Resolved
Remove/repair port propellor due to damaged fluke. Perform operational test following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 14 April 2017
Resolution: Attending Inspector verified repairs made to port propellor. Conducted operational testing while underway, test sat.
Documentation › Markings/Placards › Capacity Marking
Issued 3 April 2017
Resolved
Revise maximum passengers allowed on upper deck (reduced from 38 to 34 as per stability letter addendum 2011).
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 7 February 2018
Resolution: Attending Inspector(s) verified upper deck markings (@34 pax).
Lifesaving › Buoyant Apparatus › Painter
Issued 3 April 2017
Resolved
Renew painter lines for life floats (total of three).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified replacement of painter lines for life floats.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 April 2017
Resolved
Troubleshoot & repair fire detection system for machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 22 June 2017
Resolution: Attending Inspector verified replacement of fixed fire detection control module and performed operational test.
Stability › Watertight Integrity › General
Issued 3 April 2017
Resolved
Provide tethering devices for main deck hatches.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified the installation of tethering devices for main deck hatches.
Fire Fighting › Ventilation Systems › Ducts
Issued 3 April 2017
Resolved
Adjust ventilation closure devices for machinery space, main deck (port & starboard).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified adjustments/modifications made to main deck ventilation closure devices for machinery space.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 April 2017
Resolved
Update/revise operating instructions for fixed fire fighting system (CO2) (local & remote). Missing system schematic/ventilation closure instructions.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified changes made to operating instructions for fixed firefighting system (CO2).
Fire Fighting › Nozzles › Type
Issued 3 April 2017
Resolved
Provide proper type of fire nozzle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of proper type of fire nozzle.
Documentation › Markings/Placards › Warning Signs
Issued 3 April 2017
Resolved
Provide markings for main deck hatches (WATERTIGHT HATCH KEEP CLOSED)
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified markings for main deck hatches.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017
Resolved
Remove dead ended wiring in way of helm/console & tank room overhead.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified removal of dead ended wiring in way of console & tank room overhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017
Resolved
Provide 12V marine outlet for portable air compressor under helm/console. Current configuration has spring clips connected to fuse block.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of a 12V marine receptacle for the portable air compressor under console.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 April 2017
Resolved
Provide current/valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 August 2017
Resolution: Attending Inspector verified carriage of current FCC Safety Radiotelephony Certificate.
Engineering › Bilge Water Management System › Hose
Issued 25 January 2017
Resolved
Replace all non-approved hoses in the bilge system with an approved type (SAE J-1942) hose.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified flexible hose installations IWO fixed bilge system.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 January 2017
Resolved
Properly seal all bhd penetrations in the following bulkheads; 1)Engine room forward bhd, 2)Engine room aft bhd, and 3)Lazzarette forward bhd.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified bulkhead penetrations IWO Engine Room & Lazarette.
Stability › Watertight Integrity › General
Issued 25 January 2017
Resolved
Repair damage IWO the sheer plank caused by the travel lift.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified repairs made IWO vessels sheer clamp.
Fire Fighting › Fire Pumps › Casing
Issued 2 September 2011
Resolved
Provide vessel with a suitable fire pump with a metallic casing
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Communications › Radio Communications › VHF Radiotelephone
Issued 2 September 2011
Resolved
Provide safety radio certificate for vessel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 2 September 2011
Resolved
Provide the starboard generator with a data plate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Documentation › Certificates/Documents › Stability Letter
Issued 2 September 2011
Resolved
Post all pages of the stability letter at the operating station
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 28 September 2011
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 1 September 2011
Resolved
Type III sewage tank overboard discharge valve is not secured and heads are not locked
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2011
Resolved
Provide specifications for new and old generator to ensure replacement in kind.
Condition: Improper Installation
Due 1 October 2011
Resolved 28 September 2011
Resolution: New data plate for the replacement generator indicates the new generator is of similar capacity. The old generator was 16 KW and the new generator is 20 KW.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 September 2011
Resolved
Repair hatch covers in forward peak and lazarette to ensure watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 September 2011
Resolved
Replace holed exhaust resonator on starboard generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 September 2011
Resolved
Repair broken emergency fuel shutoff valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2011
Fire Fighting › Fire Main › Material
Issued 1 September 2011
Resolved
Replace flexible hoses on bilge pump and fire pump with approved type
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2012
Engineering › Steering Gear System › Rudder Bearing
Issued 1 September 2011
Resolved
Repair leaking port rudder packing
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2011
Resolved 2 September 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 September 2011
Resolved
Repair broken stern gateway to withstand 200# point load.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2011
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 1 September 2011
Resolved
Repair fuel leak in starboard generator fuel hose connection at the fuel injector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2011
Fire Fighting › Fire Pumps › Pressure
Issued 1 September 2011
Resolved
Install pressure gauge on discharge side of firepump
Condition: Improper Installation
Due 1 October 2011
Resolved 2 September 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2011
Resolved
Install machinery guards for both generators
Condition: Improper Installation
Due 1 October 2011
Resolved 4 October 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2011
Resolved
Properly terminate all dead end wires throughout vessel including pilot house, forward void, and engineroom
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 September 2011
Electrical › Lighting (service) › Conductor
Issued 1 September 2011
Resolved
Properly hardwire light fixture in the forward void with approve marine grade boat cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 2 September 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 September 2011
Resolved
Replace broken outlet covers in pilot house and crew areas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 2 September 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2011
Resolved
Remove or replace romex cable to outlet in crew area
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 2 September 2011
Engineering › Fuel Oil Service System › Tank
Issued 1 September 2011
Resolved
Bond fuel tanks to fill
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 September 2011
Resolved
Provide hard wired receptacles for engine block heaters or remove
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 4 October 2012
Engineering › Fuel Oil Service System › Piping
Issued 1 September 2011
Resolved
Replace wasted hose clamps for fuel fill lines on port and starboard fuel tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 2 September 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 September 2011
Resolved
Replace wasted hose clamps on port engine wet exhaust
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2011
Engineering › Fuel Oil Service System › Filter
Issued 1 September 2011
Resolved
Replace plastic petcock on starboard generator fuel filter with approved type or plug
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 September 2011
Resolved
Vessel is missing one alcohol test strip. Vessel is required to carry three.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 2 September 2011
Lifesaving › Hand Flares › Quantity
Issued 1 September 2011
Resolved
Provide one additional smoke signal. Vessel is required to have six.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 September 2011
Resolved
Provide UT report for the port and starboard fuel tanks. Contact USCG inspector to attend testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 28 September 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2011
Resolved
Post all pages of the COI in a location visible to passengers
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 28 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2011
Resolved
Vessel operator replaced the stbd generator without proper notification or authorization of the cognizant OCMI.
Action required: 705 - Other - as specified
Resolved 26 October 2011
Construction/Loadline › Structures › Door
Issued 18 February 2011
Resolved
Repair/replace stbd pilot house door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2011
Resolved 1 September 2011
Construction/Loadline › Hull › Bracket
Issued 27 January 2011
Resolved
Reattach deck blocks in fwd peak stbd side aft 3 bays.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 1 September 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 May 2010
Resolved
Crop and renew both main engine exhasut collectors IAW 46 CFR 182.430.
Due 13 May 2010
Resolved 13 May 2010
Construction/Loadline › Penetrations › Bottom Plug
Issued 10 May 2010
Resolved
Cap or plug the thru hull valves in the sewage space IAW 46 CFR 179.360.
Due 10 May 2010
Resolved 13 May 2010
Construction/Loadline › Structures › Superstructure
Issued 10 May 2010
Resolved
Install an additional sister frame on the STBD side IWO the rod space.
Due 13 May 2010
Resolved 13 May 2010
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 March 2010
Resolved
Present all sea valves for inspectionIAW 46 CFR 176.610 prior to refloating vessel. (All valves within 6 inches of water line).
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2010
Resolved 24 March 2010
Construction/Loadline › Hull › Transverse Frame
Issued 4 March 2010
Resolved
Crop and renew the following structural members IAW NVIC 7-95:
Forepeak:
Crop out planks on both sides IWO sheer strake to facilitate inspection of side frames (loose planks)
Crop out all rotten plywood IWO collision bulkhead.
Scale all rot from inner stem IWO fore deck.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 24 March 2010
Construction/Loadline › Hull › Transverse Frame
Issued 4 March 2010
Resolved
Crop and renew the following structural members IAW NVIC 7-95:
Rod space:
Refasten stanchion IWO breaker box.
Crop and renew side frame IWO starboard side Frame 16.
Renew wasted keel bolt IWO aft space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2010
Resolved 24 March 2010
Engineering › Bilge Water Management System › Strainer
Issued 4 March 2010
Resolved
Prove that the bilge suction strainers meet the minimum requirement of 46 CFR 182.510 (b).
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 13 May 2010
Construction/Loadline › Hull › Transverse Frame
Issued 4 March 2010
Resolved
Crop and renew the following structural members IAW NVIC 7-95:
Engine Room:
Floor frame IWO starboard main engine.
Deck beam IWO starboard side (3rd)
DC battery box support (any/all wasted members)
Crop and renew side frame IWO port side at battery support forward.
Crop and renew side frame IWO port side aft.
Repair hole IWO forward bulkhead at C/L IWO keel.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 24 March 2010
Construction/Loadline › Hull › Transverse Frame
Issued 4 March 2010
Resolved
Crop and renew the following structural members IAW NVIC 7-95:
Steering Room:
Crop and renew 2 side frames port side, 3 transom frames
1 floor frame IWO steering space.
Renew wasted fasteners throughout space.
Action required: 705 - Other - as specified
Due 24 March 2011
Resolved 1 September 2011
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 March 2010
Resolved
Set up clearance test on both propeller shafts. Conduct test in presence of CG inspector IAW 46 CFR 176.610.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2010
Resolved 24 March 2010
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 4 March 2010
Resolved
Make permanent repairs to the fixed fire extinguishing system (crimp hose) and (loose discharge head) IAW 46 CFR 181.400 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2010
Resolved 24 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 March 2010
Resolved
Remove both main engine exhaust pipe hoses in sewage space to facilitate further inspection IAW 46 CFR 182.430 NLT 24APR10.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 13 May 2010
Engineering › Fuel Oil Service System › Tank
Issued 4 March 2010
Resolved
Crop and renew both fuel oil tank fill connections IAW 46 CFR 182.445 NLT 24 APR 2010 (make call out of MI).
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 13 May 2010
Communications › Radio Communications › EPIRB
Issued 25 February 2009
Resolved
Provide proof of EPIRB registration under new operator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2009
Lifesaving › Lifefloat › Painter
Issued 25 February 2009
Resolved
Properly attach the painter to the lie float via the eye or around the body of the float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifefloat › Markings
Issued 25 February 2009
Resolved
Properly stencil the life floats with the max. capacity, current marking is faded.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifefloat › Paddle
Issued 25 February 2009
Resolved
Properly stencil the paddles with the vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 February 2009
Resolved
Properly attach the water light to the life float via the eye or around the body of the float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifefloat › Float Free
Issued 25 February 2009
Resolved
Provide wood slats between floats that are stacked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 February 2009
Resolved
Replace battery in one of the water lights for the life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 February 2009
Resolved
Stencil the storage location with the jacket quantity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 25 February 2009
Resolved
Replace the battaries in the life jacket lights as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 25 February 2009
Resolved
Provide vent closures for the engine room vents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2009
Fire Fighting › Nozzles › Type
Issued 25 February 2009
Resolved
Provide 3/4" brass nozzle for the fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 February 2009
Resolved
Provide a Coast Guard approved first aid kit or equivalent.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2009
Lifesaving › Hand Flares › Not on Board
Issued 28 May 2008
Resolved
Vessel had only 3 smoke floares onboard. Vessel required to have 06 smoke flares onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 29 May 2008
Resolution: Vessel replaced 03 missing smoke flares.
Engineering › Freshwater Generation System › Piping
Issued 28 May 2008
Resolved
Vessel flexible raw water hoses required to have 02 hose clamps. All hoses had 01 clamp.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 4 June 2008
Resolution: Vessel added 01 hose clamp to to all raw water hoses required to have 02 clamps.
Communications › Radio Communications › EPIRB
Issued 28 May 2008
Resolved
Hydrostatic release on EPIRB was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 29 May 2008
Resolution: Vessel replaced expired hydrostatic release.
Documentation › Logs/Records › Logbook (official)
Issued 28 May 2008
Resolved
Vessel does not record passanger counts and monthly drills in ships log.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 4 June 2008
Resolution: Vessel started new ship''s log with recorded passenger counts and drills conducted.
Documentation › Certificates/Documents › Stability Letter
Issued 28 May 2008
Resolved
Vessel did not have Stability letter onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 4 June 2008
Resolution: Vessel mounted stability letter in pilot house.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 May 2008
Resolved
Replace battery terminal connections to fit properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 4 June 2008
Resolution: Vessel replaced all battery terminals.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 May 2008
Resolved
Post C.O.I. in passenger compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 4 June 2008
Resolution: Vessel posted C.O.I. in passenger compartment.
Documentation › Markings/Placards › Warning Signs
Issued 28 May 2008
Resolved
Vessel did not have required emergency radio procedures mounted in pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Resolution: Vessel added emergency radio instructions in pilot house.
Documentation › Markings/Placards › Warning Signs
Issued 28 May 2008
Resolved
Vessel did not have warning sign for No passangers allowed in pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 4 June 2008
Resolution: Vessel placed signs outside both pilot house entrances.
Operations/Management › Pollution › Control of Garbage
Issued 28 May 2008
Resolved
Vessel had excess trash in Engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Resolution: Vessel removed all excess trash from engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2007
Resolved
Wiring in the overhead of compartment #4 not supported with metal supports. Currently all wiring is supported by plastic type supports. Metal supports are required in addition to or for replacement of current supports.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2007
Resolved 13 April 2007
Resolution: Metal wire supports were added for wiring in #4 compartment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2007
Resolved
Dead end wiring found in engine room in the area of the bilge manifold and on port MDE. Wiring is to removed.
Condition: Improper Installation
Due 25 April 2007
Resolved 13 April 2007
Resolution: All dead end wiring removed from engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2007
Resolved
Replace wire nut connectors on wash down pump with proper type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2007
Resolution: Corrected prior to completion of inspection.
Lifesaving › Lifefloat › Float-free Link
Issued 11 April 2007
Resolved
Container ring with weak link for lifefloat painter damaged.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2007
Resolution: Lifefloat painter storage ring with weaklink attachment was replaced with new.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 April 2007
Resolved
Door to portside upper deck lifejacket storage missing handle causing access to be hindered. Handle must be replaced and allow for easy access to all lifejackets stored inside.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2007
Resolution: Handle for portside lifejacket storage area was replaced.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 April 2007
Resolved
All lifejacket storage areas are to be labeled with type and number of jackets contained. All storage areas on main deck are marked with type, but missing number. Upper deck storage compartments are missing labeling for both type and number.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2007
Resolution: All lifejacket storage areas have been labeled with appropriate type and size jackets.
Lifesaving › Lifefloat › Markings
Issued 11 April 2007
Resolved
All 3 lifefloats not marked with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2007
Resolution: Corrected prior to completion of inspection.
Lifesaving › Lifefloat › Paddle
Issued 11 April 2007
Resolved
All paddles required for lifefloats not properly secured.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2007
Resolution: Corrected prior to completion of inspection.
Lifesaving › Lifefloat › Float Free
Issued 11 April 2007
Resolved
Lifefloats are stowed inside of brackets below vessel's mast and support rigging which would hinder their ability to float free. After consulting with operator it was determined that the forward stantion of the holding brackets could be lowered allowing float free arrangement. By lowering the stantion the lifefloats would be directed forward by the mast rigging allowing them to clear the mast.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2007
Resolution: Corrected prior to completion of inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 April 2007
Resolved
Bilge alarm indicating lights at operating station are not labeled with location. Label as bilge high level alarm and compartment name next to appropriate lights.
Due 25 April 2007
Resolved 13 April 2007
Resolution: All indicators at operating station have been labeled with corresponding location.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2005
Resolved
WIRE NUTS WERE USED IN THE ELECTRICAL SYSTEM.
Due 25 May 2005
Resolved 26 May 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 May 2005
Resolved
WRONG LIFEJACKET PLACARDS.
Condition: Improper Installation
Due 25 May 2005
Resolved 26 May 2005
Engineering › Bilge Water Management System › Hose
Issued 10 May 2005
Resolved
BILGE PUMP HOSE IN LAZ. NOT CLAMPED AND LOOSE.
Condition: Placed in Improper Service
Due 25 May 2005
Resolved 26 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2005
Resolved
NON AUTHORIZED JUNCTION BOXES WERE USED IN ELECTRICAL SYSTEM.
Condition: Placed in Improper Service
Due 31 May 2005
Resolved 30 May 2006
Resolution: Authorized electrical junction boxes installed.
Lifesaving › Rigid Liferafts › Carriage Requirement
Issued 10 May 2005
Resolved
LIFE FLOATS WERE TIED DOWN.
Condition: Placed in Improper Service
Due 25 May 2005
Resolved 26 May 2005
Documentation › Markings/Placards › Warning Signs
Issued 10 May 2005
Resolved
MISSING "PASSENGER EMERGENCY INSTRUCTION LIST".
Condition: Unknown
Due 25 May 2005
Resolved 26 May 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 April 2004
Resolved
REQUIRE ADDITION OF 1 CHILD PFD TO MEET COI REQUIREMENTS LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 20 April 2004
Resolution: Additional child PFD acquired.
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 April 2004
Resolved
INSTALL 13 MISSING LIGHTS ON ADULT PFD LEGACY COMPONENT DESC: Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 20 April 2004
Resolution: Additional 13 PFD lights acquired.
Engineering › Sea-water System (primary cooling)
Issued 13 April 2004
Resolved
INSTALL DOUBLE HOSE CLAMPS ON EXHAST HOSES IN THE STEERING COMPARTMENT LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 20 April 2004
Resolution: Additional clamps added as required.
Electrical › Electric Supply System (service)
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL BATTERY BOX COVER FOR BATTERY BOX LOCATED STBD SIDE AFT IN E/R. LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 May 2003
Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS IN E/R, #4 AND #5 COMPTS. LEGACY COMPONENT DESC: EXHAUST SYSTEM
Condition: Unknown
Due 1 June 2003
Resolved 29 May 2003
Electrical › Electrical Distribution System (service)
Issued 13 May 2003
Resolved
REMOVE ALL DEAD ENDED WIRING THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Electrical › Lighting (service)
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL STRAIN RELIEF DEVICES ON ALL LIGHT FIXTURES THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Strain Relief Device
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 29 May 2003
Electrical › Electric Supply System (service)
Issued 13 May 2003
Resolved
REMOVE ALL EXTENSION CORDS BEING USED AS SHIPS WIRING THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Electrical › Lighting (service)
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL GLOBES ON ALL LIGHT FIXTURES MISSING THEM THROUGHTOUT VESSEL. LEGACY COMPONENT DESC: GLOBE
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Documentation › Certificates/Documents
Issued 13 May 2003
Resolved
PROVIDE UP TO DATE COD. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 13 May 2003
Resolved
ADD ADDITIONAL RETROREFLECTIVE MATERIAL TO PFDs. NO NIGHT OPERATION UNTIL CLEARED. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Lifesaving › Rigid Liferafts
Issued 13 May 2003
Resolved
FLOAT FREE ARRANGEMENT FOR L/F & B/A NOT SATISFACTORY. RECONFIGURE TO ASSURE FLOAT FREE CAPABILITIES. LEGACY COMPONENT DESC: FLOAT FREE ARRANGEMENT
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Communications › Radio Communications
Issued 13 May 2003
Resolved
REPOSITION EPIRB TO ASSURE FLOAT FREE OPERATION. LEGACY COMPONENT DESC: EPIRB
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 13 May 2003
Resolved
SECURE REFRIDGERATOR IN PASSENGER CABIN.
Condition: Improper Installation
Due 1 June 2003
Resolved 27 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 13 May 2003
Resolved
MARK PFD STORAGE IN MAIN PASSENGER CABIN FWD 2 STORAGE AREAS, PORT AND STBD SIDES. LEGACY COMPONENT DESC: Storage
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Operations/Management › Drills/Instruction
Issued 13 May 2003
Resolved
SHOW PROOF OF LOGGED TRAINING AND DRILLS AND MONTHLY EPIRB TESTS. LEGACY COMPONENT DESC: LOGGED TRAINING AND DRILLS
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Navigation › Piloting/Steering
Issued 13 May 2003
Resolved
PROVIDE UP TO DATE LIGHT LIST AND COAST PILOT. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Navigation › Collision/Grounding Avoidance
Issued 13 May 2003
Resolved
EITHER PROVE PROPER OPERATION OF OR REMOVE 2ND RADAR. LEGACY COMPONENT DESC: Radar
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Communications › Radio Communications
Issued 13 May 2003
Resolved
PROVE PROPER OPERATION OF SSB RADIO. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Communications › Radio Communications
Issued 13 May 2003
Resolved
EITHER INSTALL AN ADDITIONAL VHF ANTENNA FOR THE 3RD VHF RADIO OR REMOVE THE RADIO. LEGACY COMPONENT DESC: VHF Radiotelephone
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Communications › Radio Communications
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL A NEW HYDROSTATIC RELEASE SERVING THE EPIRB. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Communications › Radio Communications
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL UP TO DATE NOAA REGISTRATION STICKER ON EPIRB. NO PASSENGERS OFR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Electrical › Electrical Distribution System (service)
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL COVERS OVER ELECTRICAL CONNECTIONS ON HOT WATER HEATER AND WATER PUMP IN #2 COMPT. LEGACY COMPONENT DESC: Junction Box
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Engineering › Bilge Water Management System › Pump
Issued 13 May 2003
Resolved
RENEW BILGE PUMP IN #2 COMPT.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL ONE (1) B-II EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 June 2003
Resolved 27 May 2003
Documentation › Markings/Placards
Issued 13 May 2003
Resolved
PROVIDE AND INSTALL EMERGENCY FUEL SHUTOFF PLACRDS OUTSIDE #4 COMPT. LEGACY COMPONENT DESC: EMERGENCY FUEL SHUTOFF PLACARD
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Engineering › Bilge Water Management System › Interface Detector
Issued 13 May 2003
Resolved
PROVE PROPER OPERATION OF BILGE HIGH WATER ALARM IN #4 COMPT.
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Electrical › Electrical Distribution System (service)
Issued 13 May 2003
Resolved
LABEL ALL CIRCUIT BREAKERS IN ALL BREAKER BOXES THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Circuit Breaker Boxes
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Operations/Management › Drills/Instruction
Issued 13 May 2003
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY DRILLS AND TESTS. LEGACY COMPONENT DESC: UNDERWAY DRILLS AND TESTS
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 29 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 13 May 2003
Resolved
PROVIDE MEANS OF SECURING OVERBOARD DISCHARGE OF MSD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 13 May 2003
Resolved
CLEAN THE 3/4 FULL LEVEL INDICATOR ON MSD OR INSTALL SIGHT TUBE. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Documentation › Certificates/Documents
Issued 13 May 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 2003
Resolved 29 September 2003
Lifesaving › Lifejacket/PFD (General)
Issued 13 May 2003
Resolved
PROVIDE AND MOUNT PFD DONNING PLACARD FOR HORSE COLLAR TYPE PFDs. LEGACY COMPONENT DESC: DONNING PLACRD
Condition: Placed in Improper Service
Due 1 June 2003
Resolved 27 May 2003
Lifesaving › Buoyant Apparatus
Issued 13 May 2003
Resolved
REPAIR/RENEW 2 20 MAN B/As. TOTAL PERSONS ALLOWED REDUCED TO NMT 32 TOTAL PERSONS.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Lifesaving › Lifebuoys
Issued 13 May 2003
Resolved
PROVIDE AND PROPERLY INSTALL RETRO REFLECTIVE TAPE ON RING BUOY. LEGACY COMPONENT DESC: RETRO REFLECTIVE TAPE
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2003
Resolved
RENEW EXPIRED MEDS IN FIRST AID KIT AND PROVIDE FIRST AID INSTRUCTIONS.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Engineering › Bilge Water Management System › Interface Detector
Issued 13 May 2003
Resolved
PROVE PROPER OPERATION OF BILGE PUMP INDICATOR SERVING BILGE PUMP IN #5 COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 27 May 2003
Lifesaving › Buoyant Apparatus
Issued 7 May 2002
Resolved
PROVIDE 18FT. WATER LIGHT LINE TO EACH LIFERAFT. LEGACY COMPONENT DESC: Painter
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2002
Resolution: 18 FT. WATER LIGHT LINES INSTALLED AND CONNECTED TO EACH LIFERAFT.
Lifesaving › Buoyant Apparatus
Issued 7 May 2002
Resolved
PROVIDE 100FT PAINTER FOR L/Fs. LEGACY COMPONENT DESC: Painters
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2002
Resolution: 100 FT PAINTER INSTALLED FOR L/Fs.
Construction/Loadline › Hull
Issued 6 May 2002
Resolved
MAKE PERMANENT REPAIRS TO LEAK IN AFT COMPARTMENT. LEGACY COMPONENT DESC: Transom
Condition: Improper Installation
Due 12 May 2002
Resolved 14 May 2002
Resolution: BOLTS REPLACED IN THE PORT AND STARBOARD CORNERS ALONG THE TRANSOM IN THE AFT COMPARTMENT.
Navigation
Issued 23 May 2001
Resolved
PROVIDE UP TO DATE CHARTS FOR AREAS OF OPERATION.
Condition: Unknown
Due 5 May 2025
Resolved 8 June 2001
Lifesaving
Issued 23 May 2001
Resolved
RENEW RETO TAPE ON ALL "APCO" LIFE PRESERVERS.
Condition: Unknown
Due 25 May 2001
Resolved 8 June 2001
Navigation
Issued 23 May 2001
Resolved
PLACE EMERGENCY BROADCAST PLACARD AT CONTROL STATION.
Condition: Unknown
Due 25 May 2001
Resolved 8 June 2001
Engineering
Issued 23 May 2001
Resolved
PROVIDE FUEL BOWL ON STARBOARD ENGINE FUEL FILTER.
Condition: Unknown
Due 25 May 2001
Resolved 8 June 2001
Engineering
Issued 12 April 2001
Resolved
REPLACE ALL SHAFT BEARINGS (CUTLASS) TOTAL 04.
Condition: Unknown
Due 12 April 2001
Resolved 24 April 2001
Construction/Loadline
Issued 12 April 2001
Resolved
RENEW TRANSOM FASTENERS AS IDENTIFIED DURING INSPECTION, TOTAL TO BE RENEWED IS SEVENTEEN (17).
Condition: Unknown
Due 12 April 2001
Resolved 24 April 2001
Accommodation/Occupational Safety
Issued 3 April 2000
Resolved
REPLACE FRESH WATER PUMP.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Engineering
Issued 3 April 2000
Resolved
REPLACE GENERATOR FUEL PUMP.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Construction/Loadline
Issued 17 June 1999
Resolved
REWIRE HIGH WATER BIGE ALARMS IN TANK AND STEERING COMPARTMENTS TO IDENTIFYPROPER LOCATIONS ON WHEELHOUSE ALARM PANEL.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Engineering
Issued 17 June 1999
Resolved
INVESTIGATE AND REPAIR OIL LEAKS ON PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Fire Fighting
Issued 17 June 1999
Resolved
INSTALL REQUIRED FIXED FIGHTING SYSTEM AND PERFORM OPERATIONAL TEST TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 July 1999
Resolved 23 July 1999
Construction/Loadline
Issued 9 March 1998
Resolved
replace fastener on lower portion of knee IWO #3 frame aft of bulkhed in lazerette, port side
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
properly installe weak link for port life floats
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
repair/replace waterlights as needed
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation
Issued 9 March 1998
Resolved
provide charts, tide tables, rules of the road, and copy of Subchapter T regs.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
provide proper container with markings for flares
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
properly mount EPIRB and waterlights
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Unknown
Issued 9 March 1998
Resolved
provide deck and garbage logs
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
provide 60' of line for life ring
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 9 March 1998
Resolved
provide gasket for fwd deck hatch
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 9 March 1998
Resolved
prove proper operation of bilge pump and piping system
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
provide proof of enrollment in DAPI consortium/program
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 9 March 1998
Resolved
renew/tighten packing in rudder stock
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
mount guard over front of stbd generator
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Engineering
Issued 9 March 1998
Resolved
provide ny-loc or double nut arrangement for reduction gear linkage on bothMDE's
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Fire Fighting
Issued 9 March 1998
Resolved
prove current servicing of all portable extinguishers
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Engineering
Issued 9 March 1998
Resolved
repair/replace power cord for block heater on port MDE
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Electrical
Issued 9 March 1998
Resolved
prove proper operation of emergency lighting
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Electrical
Issued 9 March 1998
Resolved
repair and mount light receptacle in #2 bottom compt.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 9 March 1998
Resolved
repair as original rotted deck IWO main deck aft, port corner
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Unknown
Issued 9 March 1998
Resolved
post maximum passenger capacity of upper deck
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Unknown
Issued 9 March 1998
Resolved
provide FCC operators license
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 9 March 1998
Resolved
properly label bilge manifold
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 9 March 1998
Resolved
repair/affix reach rod for fwd bilge suction valve
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Unknown
Issued 9 March 1998
Resolved
renew/make watertight hydraulic piping penetration through collision bulkhead
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
provide means to prevent batteries from shifting in boxes
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
provide covers for battery boxes
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
provide approved first aid kit
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Unknown
Issued 9 March 1998
Resolved
provide proof of fire/abandon ship drills
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
register EPIRB w/NOAA
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998
Resolved
prove approved/current hydrostatic release for EPIRB
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Documentation
Issued 8 May 1997
Resolved
PROVE 100% COMPLIANCE W/ CG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Documentation
Issued 8 May 1997
Resolved
PROVIDE AND INSTALL AN EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Lifesaving
Issued 8 May 1997
Resolved
PROVIDE CREW FOR AND CONDUCT MAN OVERBOARD DRILL
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Unknown
Issued 1 May 1997
Resolved
REPLACE GASKET ON FOREPEAK HATCH
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Unknown
Issued 1 May 1997
Resolved
REPLACE VENT COVER ON FOREPEAK
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Unknown
Issued 1 May 1997
Resolved
REPLACE CHAIN ON FOREPEAK HATCH
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Lifesaving
Issued 1 May 1997
Resolved
PROPERLY SECURE REFREGERATOR IN #2 STORAGE HOLD
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Electrical
Issued 1 May 1997
Resolved
REPLACE COVER TO ELECTRICAL JUNCTION BOX IN #2 STORAGE HOLD
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Electrical
Issued 1 May 1997
Resolved
PROPERLY SECURE OVERHEAD WIRES THROUOUT ENGINE ROOM
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Lifesaving
Issued 1 May 1997
Resolved
REPLACE LAZARETTE HATCH COVER
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Construction/Loadline
Issued 1 May 1997
Resolved
PROPERLY FILL IN GOUGH ON STBD BOW & PORT AMIDSHIPS
Condition: Unknown
Due 9 May 1997
Resolved 7 May 1997
Electrical
Issued 17 April 1995
Resolved
REMOVE DEAD END WIRES BETWEEN ENGINE ROOM AND ADJACENT SPACE FWD.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Engineering
Issued 17 April 1995
Resolved
BLANK OFF FILL PIPE OPENING TO CENTERLINE 150 GAL FUEL TANK WHICH IS NOT BEING USED.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Deck/Cargo
Issued 17 April 1995
Resolved
PROVIDE COPY OF VALID COI PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Electrical
Issued 17 April 1995
Resolved
REMOVE EXTENSION CORD TO FREEZER IN FWD PANEL OF #2 COMPARTMENT.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Documentation
Issued 14 October 1993
Resolved
IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR CONDUCT A NEW STABILITY TEST TO INCLUDE THE CANOPY. THE ABOVE TO BE COMPLETED BY 19NOV93.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Construction/Loadline
Issued 23 February 1990
Resolved
PROVIDE ADEQUATE SEAL FOR HYDRAULIC HOSE PENETRATING COLLISION BULKHEAD.
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Accommodation/Occupational Safety
Issued 23 February 1990
Resolved
REPLACE OR REMOVE FILTER FOR DOMESTIC WATER SYSTEM LOCATED IN 2ND COMPARTMENT AFT.
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Engineering
Issued 23 February 1990
Resolved
PROVIDE DOUBLE CLAMPS ON ALL BILGE LINE CONNECTIONS WITH HULL.
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Engineering
Issued 1 February 1989
Resolved
REPAIR BILGE PIPING CONTROL VALVE AT COLLISION BULKHEAD.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Engineering
Issued 1 February 1989
Resolved
DOUBLE CLAMP ALL. FLEXIBLE HOSE PIPE CONNECTIONS FUEL TANKS.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Engineering
Issued 1 February 1989
Resolved
REPLACE CLEAR PLASTIC VENT HOSE ON FUEL TANKS WITH A USCG TYPE "A" ACCEPT. HOSE.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Lifesaving
Issued 1 February 1989
Resolved
RENEW LIFE LINE OR LIFE FLOATS.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Engineering
Issued 1 February 1989
Resolved
PLACE THIN WALL PLATES HOSE ON SUBMERSIBLE BILGE PUMPS WITH A GOOD GRADE OF OF AUTOMOTIVE WATER HOSE.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Navigation
Issued 1 February 1989
Resolved
REPAIR DRAG LINK TO RUDDER QUADRANT FROM HYDRAULIC CYLINDER TO REMOVE EXCESS PLAY.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Electrical
Issued 1 February 1989
Resolved
INSTALL A MAIN SHAFT OFF (DISCONNECT) SWITCH ON BATTERY FOR PORT (NORTHERN LIGHTS) SERVICING GENERATOR.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Electrical
Issued 1 February 1989
Resolved
INSTALL A LINED BATTERY BOSX FOR THE STARTING BATTERY FOR THE STBD SERVICE GENERATOR.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Engineering
Issued 1 February 1989
Resolved
INSTALL SEA VALVES ON OVERBOARD DISCHARGES OF ALL BILGE PUMPS.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Construction/Loadline
Issued 8 April 1988
Resolved
THE ADDITION OF 22.5 SQ.FT. OF SAIL AREA AND THE RELOCATION OF THE 25 GAL SEWAGE TANK PERFORMED AT THE FEB HULL EXAM HAS BEEN DETERMINED TO HAVE A NEGLIGIBLE EFFECT ON THE VESSEL'S STABILITY BUT SHOULD BE RECONSIDERED IF ANY ADDITIONAL MODIFICATIONS ARE MADE.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Construction/Loadline
Issued 29 February 1988
Resolved
SUBMIT APPROPRIATE PLANS DETAILING ALL MODIFICATIONS MADE DURING FEB 88 YARD PERIOD TO THE COGNIZANT OCMI FOR APPROVAL.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Electrical
Issued 29 February 1988
Resolved
RELINE ALL BATTERY BOXES WITH LEAD OR A SUFFICIENT THICKNESS OF EQUIVALENT MATERIAL IN ORDER TO PREVENT LEAKAGE OF ANY SPILLED BATTERY ACID.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Electrical
Issued 29 February 1988
Resolved
REMOVE OR REPLACE ALL NON-UL MARINE FLOODLIGHTS WITH UL MARINE FIXTURES.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Construction/Loadline
Issued 29 February 1988
Resolved
CROP ALL ACID-SOAKED WOOD IN BATTERY BOXES BACK TO GOOD WOOD AND REBUILD, INCLUDING ALL AFFECTED BATTERY BOX SUPPORTS.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Electrical
Issued 5 March 1987
Resolved
INSTALL JUNCTION BOX FOR SPLICED CABLE FROM SHORE TIE IN STARBOARD MOTOR LOCKER.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Accommodation/Occupational Safety
Issued 5 March 1987
Resolved
WRAP METAL EXHAUST PIPING FOR BOTH MAIN ENGINES WITH LAGGING.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Unknown
Issued 5 March 1987
Resolved
INSTALL PERSONNEL GUARDS IN WAY OF FLYWHEELS FOR BOTH ENGINES AND STARBOARDGENERATOR AND OVER BOTH TAILSHAFTS IN ENGINE ROOM.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987