STARSHIP

STARSHIP is a 1979 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in April 2026, along with 93 deficiencies and 4 casualty investigations between 2013 and 2026.

Records from 2013 to 2026. Most recent: inspection, 22 April 2026.

Built
1979
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 April 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH4614
Flag
UNITED STATES
Maury page id
psix-50164

Documentation record

Registered dimensions (L × B × D)59.6 ft × 22.2 ft × 5.2 ft
Registered tonnagegross 67 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLIKIN CRAFT, INC · BEAUFORT, NC, UNITED STATES · built 1979
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portN MYRTLE BEACH, SC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 9 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 32

22 April 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8356817
24 March 2026 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8343454
23 September 2025 DAPI Audit · In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8239933
14 April 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8111521
17 December 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8048437
15 August 2024 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7982750
19 March 2024 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7881971
28 June 2023 Deficiency Check · Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7725852
14 June 2023 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7714177
5 January 2023 Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7616990
19 December 2022 Examination of Repairs · Construction Oversight · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7611094
27 May 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7470260
6 April 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7428455
19 August 2021 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7292080
20 April 2021 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7175754
2 April 2021 Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7167748
11 January 2021 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7122520
24 July 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7007643
11 December 2019 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6871729
17 May 2019 DAPI Audit · Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6674186
3 April 2019 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6655385
14 January 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6609796
2 May 2018 Examination of Repairs · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6394365
12 December 2017 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6331490
5 June 2017 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6705270
12 April 2017 Internal Structural Exam · Examination of Repairs · Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6124631
11 April 2017 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6134011
22 March 2017 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6112146
25 January 2017 Internal Structural Exam · Drydock Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6076736
3 January 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6072232
19 October 2016 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6032687
20 April 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5859209

Deficiency record · 93

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Provide 7 additional adult Type I PFDs. Maximum persons allowed is reduced by seven (7) to one-hundred-twenty-five (125) until new PFDs are provided.
Action required: 705 - Other - as specified
Resolved 14 April 2025
Resolution: New PFDs provided
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 March 2024 Resolved
Each survival craft required on a vessel by this part must meet one of the following: (2) For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition; The 25 person life float installed on the vessel was no longer in serviceable condition. Provide serviceable primary lifesaving as required per the vessels Limited Coastwise route.
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: A serviceable 22 person life float was installed on the vessel to replace the condemned 25 person life float. Vessel COI amended to reflect the new primary lifesaving capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 June 2023 Resolved
Each vessel certificated to operate on a limited coastwise oute in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Vessel is restricted to a maximum number of persons onboard of 94. Total number of passengers is 91 plus 3 crew until a new life float is provided to accommodate 50% of the total number of passengers allowed by the stability letter.
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: Provided an additional serviceable 22 person life float.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2022 Resolved
For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. Life floats were in unusable condition due to wasted netting, straps, and lines. vessel limited 3 nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2022
Resolution: O/O had life floats repaired and placed back in service
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 April 2022 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight,A hatch in a cabin top. Port and stbd aft windows are missing hatches that were previously installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 27 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 April 2022 Resolved
A hatch exposed to the weather must be watertight. Fore peak and lazzerette hatches failed hose test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 27 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2022 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Crew compartment fwd of E/R and laz has open dead end wire present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 22 April 2022
Resolution: Placed electrical connector on a junction box
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2022 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 22 April 2022
Resolution: Replaced with steel trash cans
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 April 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Gaff hook was used to recover MOB and attachment hardware for ladder was missing.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Vessel placed two shackles on the vessel and located the missing plastic boathook for MOB.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 April 2021 Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing navigational publications were found expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 19 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2021 Resolved
Vessel required to carry current/up to date navigational charts for areas transited. Existing charts were outdated.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 19 August 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 April 2021 Resolved
Vessel required to be fitted with bilge high water alarms. Existing bilge high water alarms (#5) for lazarette was inoperable at time of testing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021 Resolved
All bulkhead penetrations shall be made watertight. Exisiting watertight bulkhead penetrations IWO fixed bilge piping were found with open communication between compartments.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 April 2021 Resolved
Watertight hatch covers are required to be marked. Existing watertight hatch covers were missing required markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 April 2021 Resolved
Vessel required to be fitted with ventilation closure devices. Existing ventilation closure devices were not properly marked to identify location of installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 January 2021 Resolved
Determine the cause of the fuel oil leak on the stbd generator IWO the #3 injector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 January 2021 Resolved
Determine the cause of the leaks associated with the raw water pumps on both port and stbd main engines and repair as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 January 2021 Resolved
Renew the CO2 system piping as necessary in the forward void/rod room due to deterioration and holes, the piping must be of proper specifications, installed and tested in accordance with 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2021
Resolution: Attending Inspector witnessed satisfactory pressure test of CO2 discharge piping.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2020 Resolved
The scope of the annual inspection is the same as the inspection for certification to ensure that the vessel is in satisfactory condition, fit for service intended, and complies with all applicable regulations. Water ingress was noted in way of machinery space chines (port/starboard), fuel tank void (port) and stem (while u/w).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2020 Resolved
Vessel required to be fitted with a ring life buoy with floating water light. Existing floating water light was found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of floating water light.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2020 Resolved
Vessel required to be fitted with life floats with floating water lights. Existing floating water lights were found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of life float lights.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2020 Resolved
Vessels life floats and associated equipment required to be marked. Existing markings for life float and paddles are worn/faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified renewal of markings for life floats and paddles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2020 Resolved
A vessel must be equipped with bilge pumps capable of draining any watertight compartment under all practicable conditions. Existing power bilge pump controls were worn/faded/non-legible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified renewal of markings/labeling for bilge pump controls.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2020 Resolved
Vessel required to be fitted with seating to minimize the possibility of injury and avoid trapping occupants. Existing hardware for fixed seating was found loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified condition of seating hardware.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 July 2020 Resolved
Vessels main deck watertight hatches are required to be marked. Existing main deck watertight hatches are not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified posting of markings for watertight hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2020 Resolved
Vessels experiences a vibration in way of port propulsion shaft at various RPM's (vibrations worsen with increase in RPM's). Shaft to be drawn for further inspection NLT 31DEC2020.
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2020 Resolved
Starboard main diesel engine low oil pressure sensor was found disconnected (following engine installation).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of oil pressure gauge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019 Resolved
Watertight bulkhead between tank room/lazarette was found to be non-watertight in way of port side/outboard of keel where the previous repair meets up with original bulkhead. Temporary repairs are authorized until permanent repairs can be affected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 1 May 2020
Resolution: Attending Inspector(s) verified repairs to watertight bulkhead between lazarette and tank room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019 Resolved
Water intrusion noted IWO port hull planking @ chine (outboard of port fuel tank) in tank room. Fuel tank installation impedes access to the affected area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 1 May 2020
Resolution: Attending Inspector(s) verified repairs made IWO port chine.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019 Resolved
Water intrusion noted IWO forepeak between stem/frames 3/4. Water intrusion is only present while vessel is u/w.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 24 July 2020
Resolution: Attending Inspector cleared deficiency and re-issued via CG-835V on 24JUL2020.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2019 Resolved
Fire hose (garden hose style) requires replacement due to deterioration.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspecctor(s) verified renewal of fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2019 Resolved
Provide proper type/style of power switch for fixed bilge pump in way of machinery space.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation of proper type of switch for bilge pump.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 May 2019 Resolved
Repair ventilation closure devices/trunks in way of port & starboard side main deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified repairs/modifications made to ventilation closure devices IWO port/stbd main deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2019 Resolved
Improper fuse block installed in way of starboard machinery space @ battery bank (blade style fuses).
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation of proper type of fuse holder/block.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019 Resolved
Broken baffles in port muffler/silencer for port main diesel engine in way of tank void.
Condition: Improper/Lack of Maintenance
Due 23 May 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified replacement of port muffler assembly IWO tank room.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 23 May 2019 Resolved
Renew flexible hose connection between MSD tank (discharge) and thru-hull valve due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019 Resolved
Renew hose clamp for port main diesel engine muffler/silencer @ flex hose assembly in way of tank room.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified replacement of muffler clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 May 2019 Resolved
Provide securing device/bracket for refrigerator located in serving area (prevent movement).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of securing bracket for refrigerator in serving area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019 Resolved
Properly terminate/remove dead ended wiring in way of console/under helm.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified removal/proper termination of wiring under console/helm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019 Resolved
Limit termnals/accessories to not more than four (4) in way of starboard battery bank in machinery space.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified terminal connections to battery installations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 May 2019 Resolved
Provide current/up to date NOAA registration for vessels EPRIB.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified registration/markings for EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 May 2019 Resolved
Renew pendants in way of life floats (x3)due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified renewal of life float pendants.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019 Resolved
Renew markings for life float paddles.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified markings for life float paddles.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2019 Resolved
Repair/replace naviational lighting assemblies due to age/deterioration (lenses are frosted/oxidized) for port & starboard side lights.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation/operation of navigational lights.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 May 2019 Resolved
Provide current/up to date navigational publications for areas transited.
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified carrige of current/up to date navigational publications for areas transited.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019 Resolved
Repair life float stanchions IWO starboard life flaot arrangement (outboard).
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified repairs made to life float stanchions.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019 Resolved
Renew batteries in way of lifesaving equipment (floating water lights).
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified renewal of batteries IWO floating water lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2018 Resolved
Attending Inspector(s) identified "rot" IWO upper deck bulwark, port side, outboard of ladder. Issued requirement on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 May 2018 Resolved
Vessel did not carry current/up to date navigational publications (CG Light List, Tide Tables, Tidal Current Tables, Coast Pilot) for areas transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2018 Resolved
Electric submersible bilge pump/float switch failed to operate properly during testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector witnessed repairs made to float switch and performed satisfactory operational test.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2018 Resolved
Floating water lights for life floats not equipped with proper batteries as per manufacturers instructions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of proper battery type for floating water lights for life floats.
Lifesaving › Lifefloat › Pendant
Issued 2 May 2018 Resolved
Pendants for life floats required replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified replacement of life float pendants.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2018 Resolved
Renew line for floating water lights for lifefloat installation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified renewal of line for floating water light for life floats.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 2 May 2018 Resolved
Refrigerator not properly secured to prevent movement IWO galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of a bracket to secure regrigerator from movement IWO galley/serving area.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
Thru-hull valve IWO tank room not properly installed/secured/capped off.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of a cap/plug for thru-hull valve located outboard keel, port side IWO tank room.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 2 May 2018 Resolved
Ventilation piping for port & starboard fuel oil tanks were not properly installed/terminated outside of the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of fuel oil vents for port & starboard fuel tanks IWO tank room.
Engineering › Bilge Water Management System › Valve
Issued 2 May 2018 Resolved
Submersible bilge pump piping IWO tank room (stbd) not equipped with stop valve at side shell (<18" deepest load waterline).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of stop valve @ side shell IWO tank room for electric submersible bilge pump discharge hose.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 May 2018 Resolved
Exhaust flex hoses required adjustment/tightening IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of new clamps and the adjustment/tightening of existing clamps for exhaust flexible hose connections IWO lazarette.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
Main deck watertight hatches required servicing/adjustment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector witnessed operation of main deck watertight hatches for forepeak and lazarette.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 2 May 2018 Resolved
Service/repair/replace thru-hull valves IWO port & starboard ships service diesel generator exhaust valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified the operation of the port & starboard exhaust discharge thru-hull valves for SSDG's.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 May 2018 Resolved
Ventilation ducts along main deck (port & starboard) require repair/replacement due to deterioration. Space is protected by fixed CO2 system. Ducts serve as primary ventilation closures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018 Resolved
Rot noted IWO vertical transverse frames (approx. 8) along transom. All frames were marked accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2018 Resolved
Rot noted IWO main deck support beam (4th frame fwd of transom) & port side shell in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018 Resolved
Rot noted IWO port & starboard main deck support beams/structure in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2018 Resolved
Crop/renew deck planking @ watertight hatch for lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018 Resolved
Repair/replace main deck beam IWO forepeak frames #1/2 where marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2018 Resolved
Crop/renew main deck planking IWO forepeak watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018 Resolved
Rot noted IWO forepeak side shell framing (stbd)#1/2/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018 Resolved
Rot noted IWO watertight bulkhead/side shell frame in forepeak (stbd).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018 Resolved
Rot noted IWO forepeak frames #4/7 (port).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2018 Resolved
Repair/replace hardware for transverse framing IWO forepeak where marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 May 2018 Resolved
Renew flexible shaft log boots due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2018 Resolved
Attending Inspector(s) identified "rot" IWO upper deck, starboard side ceiling (aft of pilothouse). Requirement issued on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2018 Resolved
Attending Inspector(s) identified at least three "soft spots" IWO upper deck (aft of pilothouse). Requirement issued on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2018 Resolved
Attending Inspector(s) called out rot in way of port upper deck planking IWO aft cabin bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Attending Inspector(s) verified final repairs for upper deck planking IWO aft cabin bulkhead.
Construction/Loadline › Structures › Superstructure
Issued 12 December 2017 Resolved
Repair main deck overhead/upper deck transverse beams IAW good marine practice following port main diesel engine installation.
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Attending Inspector(s) witness final repairs made to upper deck beams and planking.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 August 2017 Resolved
Port main diesel engine exhaust riser/mixer was fractured.
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 7 February 2018
Resolution: Attending Inspector(s) verified installation of port main diesel engine exhaust risers (inboard/outboard).
Stability › Watertight Integrity › General
Issued 25 August 2017 Resolved
Vessels main deck watertight hatches failed to operate/seal properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2017
Resolution: Attending Inspector verified repairs/adjustments to main deck watertight hatches and performed operational test.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 April 2017 Resolved
Remove/repair port propellor due to damaged fluke. Perform operational test following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 14 April 2017
Resolution: Attending Inspector verified repairs made to port propellor. Conducted operational testing while underway, test sat.
Documentation › Markings/Placards › Capacity Marking
Issued 3 April 2017 Resolved
Revise maximum passengers allowed on upper deck (reduced from 38 to 34 as per stability letter addendum 2011).
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 7 February 2018
Resolution: Attending Inspector(s) verified upper deck markings (@34 pax).
Lifesaving › Buoyant Apparatus › Painter
Issued 3 April 2017 Resolved
Renew painter lines for life floats (total of three).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified replacement of painter lines for life floats.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 April 2017 Resolved
Troubleshoot & repair fire detection system for machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 22 June 2017
Resolution: Attending Inspector verified replacement of fixed fire detection control module and performed operational test.
Stability › Watertight Integrity › General
Issued 3 April 2017 Resolved
Provide tethering devices for main deck hatches.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified the installation of tethering devices for main deck hatches.
Fire Fighting › Ventilation Systems › Ducts
Issued 3 April 2017 Resolved
Adjust ventilation closure devices for machinery space, main deck (port & starboard).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified adjustments/modifications made to main deck ventilation closure devices for machinery space.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 April 2017 Resolved
Update/revise operating instructions for fixed fire fighting system (CO2) (local & remote). Missing system schematic/ventilation closure instructions.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified changes made to operating instructions for fixed firefighting system (CO2).
Fire Fighting › Nozzles › Type
Issued 3 April 2017 Resolved
Provide proper type of fire nozzle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of proper type of fire nozzle.
Documentation › Markings/Placards › Warning Signs
Issued 3 April 2017 Resolved
Provide markings for main deck hatches (WATERTIGHT HATCH KEEP CLOSED)
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified markings for main deck hatches.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017 Resolved
Remove dead ended wiring in way of helm/console & tank room overhead.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified removal of dead ended wiring in way of console & tank room overhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017 Resolved
Provide 12V marine outlet for portable air compressor under helm/console. Current configuration has spring clips connected to fuse block.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of a 12V marine receptacle for the portable air compressor under console.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 April 2017 Resolved
Provide current/valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 August 2017
Resolution: Attending Inspector verified carriage of current FCC Safety Radiotelephony Certificate.
Engineering › Bilge Water Management System › Hose
Issued 25 January 2017 Resolved
Replace all non-approved hoses in the bilge system with an approved type (SAE J-1942) hose.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified flexible hose installations IWO fixed bilge system.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 January 2017 Resolved
Properly seal all bhd penetrations in the following bulkheads; 1)Engine room forward bhd, 2)Engine room aft bhd, and 3)Lazzarette forward bhd.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified bulkhead penetrations IWO Engine Room & Lazarette.
Stability › Watertight Integrity › General
Issued 25 January 2017 Resolved
Repair damage IWO the sheer plank caused by the travel lift.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified repairs made IWO vessels sheer clamp.

Casualty record · 4

3 April 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4564777
11 April 2017Routine · role: Involved in a Marine Casualty · activity 6134011
5 June 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6705270
24 March 2026Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8343454
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.