Records from 2013 to 2026. Most recent: inspection, 22 April 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Provide 7 additional adult Type I PFDs.
Maximum persons allowed is reduced by seven (7) to one-hundred-twenty-five (125) until new PFDs are provided.
Action required: 705 - Other - as specified
Resolved 14 April 2025
Resolution: New PFDs provided
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 March 2024
Resolved
Each survival craft required on a vessel by this part must meet one of the following: (2) For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition;
The 25 person life float installed on the vessel was no longer in serviceable condition.
Provide serviceable primary lifesaving as required per the vessels Limited Coastwise route.
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: A serviceable 22 person life float was installed on the vessel to replace the condemned 25 person life float. Vessel COI amended to reflect the new primary lifesaving capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 June 2023
Resolved
Each vessel certificated to operate on a limited coastwise oute in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board.
Vessel is restricted to a maximum number of persons onboard of 94. Total number of passengers is 91 plus 3 crew until a new life float is provided to accommodate 50% of the total number of passengers allowed by the stability letter.
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: Provided an additional serviceable 22 person life float.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2022
Resolved
For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition.
Life floats were in unusable condition due to wasted netting, straps, and lines. vessel limited 3 nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2022
Resolution: O/O had life floats repaired and placed back in service
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 April 2022
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight,A hatch in a cabin top.
Port and stbd aft windows are missing hatches that were previously installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 27 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 April 2022
Resolved
A hatch exposed to the weather must be watertight.
Fore peak and lazzerette hatches failed hose test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 27 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor.
Crew compartment fwd of E/R and laz has open dead end wire present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 22 April 2022
Resolution: Placed electrical connector on a junction box
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2022
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 22 April 2022
Resolution: Replaced with steel trash cans
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 April 2022
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
Gaff hook was used to recover MOB and attachment hardware for ladder was missing.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Vessel placed two shackles on the vessel and located the missing plastic boathook for MOB.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 April 2021
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing navigational publications were found expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 19 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2021
Resolved
Vessel required to carry current/up to date navigational charts for areas transited. Existing charts were outdated.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 19 August 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 April 2021
Resolved
Vessel required to be fitted with bilge high water alarms. Existing bilge high water alarms (#5) for lazarette was inoperable at time of testing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021
Resolved
All bulkhead penetrations shall be made watertight. Exisiting watertight bulkhead penetrations IWO fixed bilge piping were found with open communication between compartments.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 April 2021
Resolved
Watertight hatch covers are required to be marked. Existing watertight hatch covers were missing required markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 April 2021
Resolved
Vessel required to be fitted with ventilation closure devices. Existing ventilation closure devices were not properly marked to identify location of installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 19 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 January 2021
Resolved
Determine the cause of the fuel oil leak on the stbd generator IWO the #3 injector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 January 2021
Resolved
Determine the cause of the leaks associated with the raw water pumps on both port and stbd main engines and repair as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 January 2021
Resolved
Renew the CO2 system piping as necessary in the forward void/rod room due to deterioration and holes, the piping must be of proper specifications, installed and tested in accordance with 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2021
Resolution: Attending Inspector witnessed satisfactory pressure test of CO2 discharge piping.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2020
Resolved
The scope of the annual inspection is the same as the inspection for certification to ensure that the vessel is in satisfactory condition, fit for service intended, and complies with all applicable regulations. Water ingress was noted in way of machinery space chines (port/starboard), fuel tank void (port) and stem (while u/w).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2020
Resolved
Vessel required to be fitted with a ring life buoy with floating water light. Existing floating water light was found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of floating water light.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2020
Resolved
Vessel required to be fitted with life floats with floating water lights. Existing floating water lights were found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of life float lights.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2020
Resolved
Vessels life floats and associated equipment required to be marked. Existing markings for life float and paddles are worn/faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified renewal of markings for life floats and paddles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2020
Resolved
A vessel must be equipped with bilge pumps capable of draining any watertight compartment under all practicable conditions. Existing power bilge pump controls were worn/faded/non-legible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified renewal of markings/labeling for bilge pump controls.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2020
Resolved
Vessel required to be fitted with seating to minimize the possibility of injury and avoid trapping occupants. Existing hardware for fixed seating was found loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified condition of seating hardware.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 July 2020
Resolved
Vessels main deck watertight hatches are required to be marked. Existing main deck watertight hatches are not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified posting of markings for watertight hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2020
Resolved
Vessels experiences a vibration in way of port propulsion shaft at various RPM's (vibrations worsen with increase in RPM's). Shaft to be drawn for further inspection NLT 31DEC2020.
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2020
Resolved
Starboard main diesel engine low oil pressure sensor was found disconnected (following engine installation).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 24 July 2020
Resolution: Attending Inspector verified operation of oil pressure gauge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Watertight bulkhead between tank room/lazarette was found to be non-watertight in way of port side/outboard of keel where the previous repair meets up with original bulkhead. Temporary repairs are authorized until permanent repairs can be affected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 1 May 2020
Resolution: Attending Inspector(s) verified repairs to watertight bulkhead between lazarette and tank room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Water intrusion noted IWO port hull planking @ chine (outboard of port fuel tank) in tank room. Fuel tank installation impedes access to the affected area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 1 May 2020
Resolution: Attending Inspector(s) verified repairs made IWO port chine.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Water intrusion noted IWO forepeak between stem/frames 3/4. Water intrusion is only present while vessel is u/w.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 24 July 2020
Resolution: Attending Inspector cleared deficiency and re-issued via CG-835V on 24JUL2020.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2019
Resolved
Fire hose (garden hose style) requires replacement due to deterioration.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspecctor(s) verified renewal of fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2019
Resolved
Provide proper type/style of power switch for fixed bilge pump in way of machinery space.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation of proper type of switch for bilge pump.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 May 2019
Resolved
Repair ventilation closure devices/trunks in way of port & starboard side main deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified repairs/modifications made to ventilation closure devices IWO port/stbd main deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2019
Resolved
Improper fuse block installed in way of starboard machinery space @ battery bank (blade style fuses).
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation of proper type of fuse holder/block.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019
Resolved
Broken baffles in port muffler/silencer for port main diesel engine in way of tank void.
Condition: Improper/Lack of Maintenance
Due 23 May 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified replacement of port muffler assembly IWO tank room.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 23 May 2019
Resolved
Renew flexible hose connection between MSD tank (discharge) and thru-hull valve due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019
Resolved
Renew hose clamp for port main diesel engine muffler/silencer @ flex hose assembly in way of tank room.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified replacement of muffler clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 May 2019
Resolved
Provide securing device/bracket for refrigerator located in serving area (prevent movement).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of securing bracket for refrigerator in serving area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019
Resolved
Properly terminate/remove dead ended wiring in way of console/under helm.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified removal/proper termination of wiring under console/helm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019
Resolved
Limit termnals/accessories to not more than four (4) in way of starboard battery bank in machinery space.
Condition: Improper Installation
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified terminal connections to battery installations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 May 2019
Resolved
Provide current/up to date NOAA registration for vessels EPRIB.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified registration/markings for EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 May 2019
Resolved
Renew pendants in way of life floats (x3)due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified renewal of life float pendants.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019
Resolved
Renew markings for life float paddles.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified markings for life float paddles.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2019
Resolved
Repair/replace naviational lighting assemblies due to age/deterioration (lenses are frosted/oxidized) for port & starboard side lights.
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified installation/operation of navigational lights.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 May 2019
Resolved
Provide current/up to date navigational publications for areas transited.
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified carrige of current/up to date navigational publications for areas transited.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019
Resolved
Repair life float stanchions IWO starboard life flaot arrangement (outboard).
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified repairs made to life float stanchions.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2019
Resolved
Renew batteries in way of lifesaving equipment (floating water lights).
Condition: Improper/Lack of Maintenance
Due 23 June 2019
Resolved 12 September 2019
Resolution: Attending Inspector(s) verified renewal of batteries IWO floating water lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2018
Resolved
Attending Inspector(s) identified "rot" IWO upper deck bulwark, port side, outboard of ladder. Issued requirement on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 May 2018
Resolved
Vessel did not carry current/up to date navigational publications (CG Light List, Tide Tables, Tidal Current Tables, Coast Pilot) for areas transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2018
Resolved
Electric submersible bilge pump/float switch failed to operate properly during testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector witnessed repairs made to float switch and performed satisfactory operational test.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2018
Resolved
Floating water lights for life floats not equipped with proper batteries as per manufacturers instructions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of proper battery type for floating water lights for life floats.
Lifesaving › Lifefloat › Pendant
Issued 2 May 2018
Resolved
Pendants for life floats required replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified replacement of life float pendants.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2018
Resolved
Renew line for floating water lights for lifefloat installation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified renewal of line for floating water light for life floats.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 2 May 2018
Resolved
Refrigerator not properly secured to prevent movement IWO galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of a bracket to secure regrigerator from movement IWO galley/serving area.
Stability › Watertight Integrity › General
Issued 2 May 2018
Resolved
Thru-hull valve IWO tank room not properly installed/secured/capped off.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of a cap/plug for thru-hull valve located outboard keel, port side IWO tank room.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 2 May 2018
Resolved
Ventilation piping for port & starboard fuel oil tanks were not properly installed/terminated outside of the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of fuel oil vents for port & starboard fuel tanks IWO tank room.
Engineering › Bilge Water Management System › Valve
Issued 2 May 2018
Resolved
Submersible bilge pump piping IWO tank room (stbd) not equipped with stop valve at side shell (<18" deepest load waterline).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of stop valve @ side shell IWO tank room for electric submersible bilge pump discharge hose.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 May 2018
Resolved
Exhaust flex hoses required adjustment/tightening IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified installation of new clamps and the adjustment/tightening of existing clamps for exhaust flexible hose connections IWO lazarette.
Stability › Watertight Integrity › General
Issued 2 May 2018
Resolved
Main deck watertight hatches required servicing/adjustment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector witnessed operation of main deck watertight hatches for forepeak and lazarette.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 2 May 2018
Resolved
Service/repair/replace thru-hull valves IWO port & starboard ships service diesel generator exhaust valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 10 May 2018
Resolution: Attending Inspector verified the operation of the port & starboard exhaust discharge thru-hull valves for SSDG's.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 May 2018
Resolved
Ventilation ducts along main deck (port & starboard) require repair/replacement due to deterioration. Space is protected by fixed CO2 system. Ducts serve as primary ventilation closures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO vertical transverse frames (approx. 8) along transom. All frames were marked accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2018
Resolved
Rot noted IWO main deck support beam (4th frame fwd of transom) & port side shell in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO port & starboard main deck support beams/structure in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2018
Resolved
Crop/renew deck planking @ watertight hatch for lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Repair/replace main deck beam IWO forepeak frames #1/2 where marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 2 May 2018
Resolved
Crop/renew main deck planking IWO forepeak watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO forepeak side shell framing (stbd)#1/2/3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO watertight bulkhead/side shell frame in forepeak (stbd).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Stiffener
Issued 2 May 2018
Resolved
Rot noted IWO forepeak frames #4/7 (port).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 2 May 2018
Resolved
Repair/replace hardware for transverse framing IWO forepeak where marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 May 2018
Resolved
Renew flexible shaft log boots due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2018
Resolved
Attending Inspector(s) identified "rot" IWO upper deck, starboard side ceiling (aft of pilothouse). Requirement issued on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2018
Resolved
Attending Inspector(s) identified at least three "soft spots" IWO upper deck (aft of pilothouse). Requirement issued on 05NOV2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Corrected at drydock.
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2018
Resolved
Attending Inspector(s) called out rot in way of port upper deck planking IWO aft cabin bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Attending Inspector(s) verified final repairs for upper deck planking IWO aft cabin bulkhead.
Construction/Loadline › Structures › Superstructure
Issued 12 December 2017
Resolved
Repair main deck overhead/upper deck transverse beams IAW good marine practice following port main diesel engine installation.
Action required: 705 - Other - as specified
Resolved 26 February 2018
Resolution: Attending Inspector(s) witness final repairs made to upper deck beams and planking.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 August 2017
Resolved
Port main diesel engine exhaust riser/mixer was fractured.
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 7 February 2018
Resolution: Attending Inspector(s) verified installation of port main diesel engine exhaust risers (inboard/outboard).
Stability › Watertight Integrity › General
Issued 25 August 2017
Resolved
Vessels main deck watertight hatches failed to operate/seal properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2017
Resolution: Attending Inspector verified repairs/adjustments to main deck watertight hatches and performed operational test.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 April 2017
Resolved
Remove/repair port propellor due to damaged fluke. Perform operational test following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 14 April 2017
Resolution: Attending Inspector verified repairs made to port propellor. Conducted operational testing while underway, test sat.
Documentation › Markings/Placards › Capacity Marking
Issued 3 April 2017
Resolved
Revise maximum passengers allowed on upper deck (reduced from 38 to 34 as per stability letter addendum 2011).
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 7 February 2018
Resolution: Attending Inspector(s) verified upper deck markings (@34 pax).
Lifesaving › Buoyant Apparatus › Painter
Issued 3 April 2017
Resolved
Renew painter lines for life floats (total of three).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified replacement of painter lines for life floats.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 April 2017
Resolved
Troubleshoot & repair fire detection system for machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 22 June 2017
Resolution: Attending Inspector verified replacement of fixed fire detection control module and performed operational test.
Stability › Watertight Integrity › General
Issued 3 April 2017
Resolved
Provide tethering devices for main deck hatches.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified the installation of tethering devices for main deck hatches.
Fire Fighting › Ventilation Systems › Ducts
Issued 3 April 2017
Resolved
Adjust ventilation closure devices for machinery space, main deck (port & starboard).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified adjustments/modifications made to main deck ventilation closure devices for machinery space.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 April 2017
Resolved
Update/revise operating instructions for fixed fire fighting system (CO2) (local & remote). Missing system schematic/ventilation closure instructions.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified changes made to operating instructions for fixed firefighting system (CO2).
Fire Fighting › Nozzles › Type
Issued 3 April 2017
Resolved
Provide proper type of fire nozzle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of proper type of fire nozzle.
Documentation › Markings/Placards › Warning Signs
Issued 3 April 2017
Resolved
Provide markings for main deck hatches (WATERTIGHT HATCH KEEP CLOSED)
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified markings for main deck hatches.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017
Resolved
Remove dead ended wiring in way of helm/console & tank room overhead.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified removal of dead ended wiring in way of console & tank room overhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017
Resolved
Provide 12V marine outlet for portable air compressor under helm/console. Current configuration has spring clips connected to fuse block.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of a 12V marine receptacle for the portable air compressor under console.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 April 2017
Resolved
Provide current/valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 25 August 2017
Resolution: Attending Inspector verified carriage of current FCC Safety Radiotelephony Certificate.
Engineering › Bilge Water Management System › Hose
Issued 25 January 2017
Resolved
Replace all non-approved hoses in the bilge system with an approved type (SAE J-1942) hose.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified flexible hose installations IWO fixed bilge system.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 January 2017
Resolved
Properly seal all bhd penetrations in the following bulkheads; 1)Engine room forward bhd, 2)Engine room aft bhd, and 3)Lazzarette forward bhd.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified bulkhead penetrations IWO Engine Room & Lazarette.
Stability › Watertight Integrity › General
Issued 25 January 2017
Resolved
Repair damage IWO the sheer plank caused by the travel lift.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 22 March 2017
Resolution: Attending Inspectors verified repairs made IWO vessels sheer clamp.