CONTINENTAL SHELF

CONTINENTAL SHELF is a 1987 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in April 2026, along with 103 deficiencies — 4 with no resolution recorded — and 3 casualty investigations in 2009.

Records from 2009 to 2026. Most recent: inspection, 27 April 2026.

Built
1987
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ2500
297911
Flag
UNITED STATES
Maury page id
psix-297911

Documentation record

Registered dimensions (L × B × D)81.3 ft × 21.7 ft × 7.4 ft
Registered tonnagegross 82 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS OF STUART,IN · STUART, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORTH MYRTLE BEACH, SC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Net Ton
82 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUPER VOYAGER III Passenger (Inspected) · MISLE 46828 · 27 May 2022 · activity 7470260STARSHIP Passenger (Inspected) · MISLE 50164 · 27 May 2022 · activity 7470260

Inspection history · 29

27 April 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8358291
20 January 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8298471
11 August 2025 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8207698
10 March 2025 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8087566
18 July 2024 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7965754
20 March 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7882624
26 January 2024 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7856073
13 April 2023 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7667958
27 May 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7470260
13 April 2022 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7426253
8 January 2022 Plan Review "T" Boat
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7378825
7 January 2022 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7376857
29 April 2021 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7339775
21 April 2021 DAPI Audit · Examination of Repairs · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7175783
5 November 2020 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7090806
13 April 2020 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6938855
17 March 2020 COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6923407
17 March 2020 Plan Review "T" Boat · Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6938935
14 January 2020 Drydock Exam · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6888861
16 May 2019 Examination of Repairs · Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6674167
15 March 2019 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6654637
15 June 2018 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6659224
6 June 2018 DAPI Audit · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6485477
25 May 2018 Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6485484
23 January 2018 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6339295
6 April 2017 Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6112173
1 April 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5860130
30 March 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5843544
12 January 2016 Internal Structural Exam · Hull Examination · Drydock Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5795654

Deficiency record · 103

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 April 2026 No resolution recorded
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds Repair hairline fracture in the starboard rudder baseplate at the end of the 2026 season when the vessel goes to the yard for regular maintenance.
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 27 April 2026 No resolution recorded
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Make proper repairs to cracked welds on railing and railing base plate on the upper deck starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2026 No resolution recorded
Exhaust gas must not leak from the piping or any connections. Weld pinhole leak in exhaust pipe inboard port side.
Action required: 16 - Rectify deficiencies w/in 14 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 April 2026 No resolution recorded
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Properly attach both watertight hatches on the main deck. Remove the plastic link chain currently installed.
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 March 2025 Resolved
EPIRB hydrostatic release unit was expired.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2025
Resolution: HRU provided
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 March 2025 Resolved
Distress flares were expired
Action required: 10 - Deficiency Rectified
Resolved 10 March 2025
Resolution: 12 new distress signals provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 June 2022 Resolved
A hatch exposed to the weather must be watertight. Fore peak and lazzerette hatches leaked in center shaft of Freeman brand hatch. O/O to replace hatches before 28FEB2023. Until hatches are replaced fwd and aft draft readings must be taken and recorded in vessel log book. Any appreciable change in draft readings must be investigated and immediately report to USCG Sector Charleston Inspections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 April 2023
Resolution: New hatches installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 April 2022 Resolved
For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. Life floats need to be serviced, coating is wasted and paddles are deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Life floats were serviced and paddles replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 April 2022 Resolved
A hatch exposed to the weather must be watertight. Fore peak and lazzerette hatches failed hose test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Repairs were made, both hatches still dripped from center. See CG 835 issued 02Jun2022 to replace before 28FEB2023 and to conduct daily draft readings.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 April 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB Hydrostatic release expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Hydrostatic release installed, improper date was marked O/O remarked withproof of purchase present to expire May 2024.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 April 2022 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Not being logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: EPIRB testing is being logged as required.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 20 April 2022 Resolved
The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Rescue platform is too long platform was approx 18" under the water.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Rescue platform was adjusted to the proper height.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Missing chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Updated chart was placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2022 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. upper port and fwd life ring need to be remarked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Life rings were remarked.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 April 2022 Resolved
Fire pump. The pump outlet shall be fitted with pressure gauge. Pressure gauge was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: Fire pump gauge was replaced, informed O/O that the 300psi gauge works but a gauge with a smaller gradient but greater than 60 psi would be easier to read.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 April 2022 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Crew had troubles getting pressure to the fire main, the overboard vale was left open. Vessel master conducted training with crew on proper valve alignment.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 April 2022
Resolution: Master reviewed fire man valve configuration with crew.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 13 April 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Chocker rope was used to recover MOB, life sling or rope tied in non-tightening knot should be used.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: O/O made a harness with eyes in a line and snap clips for MOB rescue.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2022 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 2 June 2022
Resolution: COI posteed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2022 Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel operating with 03 deficiencies open past due date
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Deficencies were corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2021 Resolved
Vessels life floats are required to be marked with vessels name and capacity. Existing life floats (new) are missing vessels name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 7 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2021 Resolved
Vessel required to carry current/up to date navigational charts for areas transited. Vessel did not carry current/up to date charts for areas transitted & existing chart was outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 19 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2021 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] conductor(s) between battery box and prime movers are deteriorated (outer jacketing), requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 19 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 April 2021 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull. The flexible oil line for oil pressure gauge in way of starboard main diesel engine was found deteriorated/corroded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 19 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2021 Resolved
When the flexible fill section is a non-conductor of electricity, the metallic sections of the filling pipe separated shall be joined by a conductor for protection against static electricity. Existing fuel fill pipes (x3) at the main deck are not equipped with bonding strap(s).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 19 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 March 2020 Resolved
Vessels radio-telephone installation is required to be verified by FCC technician in order to be issued a FCC Safety Radio-telephony Certificate. Vessels Safety Radio-telephony Certificate was expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 13 April 2020
Resolution: Attending Inspector(s) verified renewal of FCC Safety Radio-telephony Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 March 2020 Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Vessels navigational publications were expired (2019).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 8 April 2021
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2020 Resolved
Vessel required to carry at least 100% life floats for total persons on board. Vessels life floats require maintenance/repair to outer jacket and netting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 21 April 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2020 Resolved
Fixed fire extinguishing system requires servicing/inspection at each initial and subsequent inspection for certification. Vessels fixed CO2 system requires servicing/inspection since the vessel underwent a COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 13 April 2020
Resolution: Attending Inspector(s) witnesses satisfactory servicing of fixed fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2020 Resolved
Vessel required to be equipped with fixed bilge system for dewatering each compartment. Owner/Operator to develop diagram and labeling system for primary and secondary bilge systems to ensure proper alignment/operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 3 December 2020
Resolution: Attending Inspector(s) verified markings/labeling for fixed bilge system.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 March 2020 Resolved
Vessel required to be fitted with bilge high water alarms. Bilge high water alarm IWO engine room was broken/inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 13 April 2020
Resolution: Attending Inspector(s) verified repairs to bilge high water alarm IWO engine room and witnessed satisfactory operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2020 Resolved
Vessels SSDG required to be equipped with Voltmeter. Vessels SSDG voltmeter was broken/inoperable at time of inspection (locally @ SSDG).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 3 December 2020
Resolution: Attending Inspector(s) verified installation of volt meter for SSDG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 March 2020 Resolved
Vessel's SSDG required to be equipped with ampere meter. Vessel's SSDG ampere meter was broken/inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2020
Resolved 8 April 2021
Resolution: Attending Inspector(s) verfied repairs to SSDG amperage meter.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 March 2020 Resolved
Vessel required to be equipped with Cat. 1 406 Mhz EPIRB. Vessel's EPIRB battery was found expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2020
Resolution: Attending Inspector(s) verified installation of (new) EPIRB.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 6 March 2020 Resolved
The vessel must, in each condition of loading and operation, comply with the applicable requirements of Part 170 and 171. The owner has replaced the center main engine and the resultant change to9 lightship displacement weight is unknown. The owner must submit a letter to the MSC requesting a determination regarding this matte. The request must include the details of the modification and the specifications sheets for the old and new engines, as well as the batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2020
Resolution: MSC reviewed/approved lightship changes as submitted by vessels owner/operator.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 November 2019 Resolved
Crop/renew main deck IWO lazarette due to delamination (stbd/fwd). Delamination is located on the underside of the decking (re-issued requirement).
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 28 January 2020
Resolution: Repairs made during 2020 drydock @ SEC NC.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 November 2019 Resolved
Vessels shaft log IWO centerline main diesel engine/shafting requires repair/replacement due to fractures/water intrusion. Temp. repairs are not feasible due to interferences (SSDG).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 30 January 2020
Resolution: Repairs made during 2020 drydock @ SEC NC.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 May 2019 Resolved
Painter lines for port life float installation was improperly configured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified painter line configurations.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2019 Resolved
Vessel employs multiple first aid kits. Recommend consolidating first aid kits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 26 November 2019
Resolution: Attending Inspector(s) verified contents of First Aid Kits.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 May 2019 Resolved
EPIRB NOAA registration expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified EPIRB registration.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 May 2019 Resolved
Navigational publications for areas transited were expired/outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 26 November 2019
Resolution: Attending Inspector(s) verified navigational publications.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019 Resolved
Electrical junction box missing faceplate/cover IWO stbd/fwd accomodations space
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of face plate/cover.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2019 Resolved
Provide alcohol testing device(s). Vessels M-PAK kits contain alcohol test strips, however, they are set to expire in June 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 26 November 2019
Resolution: Attending Inspector verified carriage of alcohol testing equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2019 Resolved
Electric submersible bilge pumps are not properly secured to prevent movement/floating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of electric submersible bilge pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2019 Resolved
Fixed bilge suction piping IWO machinery space improperly secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of fixed bilge piping IWO machinery space.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 May 2019 Resolved
Provide lens cover for lighting IWO machinery space (fwd bulkhead).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of lens covers for machinery space lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2019 Resolved
Remove existing "wrap" from raw water piping IWO aft SSDG downsteam of strainer for further inspection. Attending Inspector suspects wastage/leaks in piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified renewal of piping IWO SSDG raw water piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019 Resolved
Improper type of fuse block installed IWO aft SSDG (blade style).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of proper type/size of fuse block IWO SSDG (stbd).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2019 Resolved
Renew flexible hose assembly IWO aft main diesel engine between sea chest and strainer assembly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verfied renewal of flexible hose(s) IWO machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2019 Resolved
Provide bonding straps for fuel tank fill(s).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of bonding straps for fuel tank fills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2019 Resolved
Provide double hose clamps IWO centerline main diesel engine jabsco/bilge pump flexible hose connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of proper qty/type of clamps IWO jabsco bilge pump (secondary).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2019 Resolved
Provide hardware for machinery guards (centerline/stbd main diesel engines belt drive).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of mounting hardware for rotating machinery guards IWO centerline MDE.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 May 2019 Resolved
Properly secure bilge high water alarms to prevent movement (throughout vessel).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of bilge high water alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 June 2018 Resolved
Vessel required to maintain life floats in a serviceable condition. Two existing life floats were beyond their service life due to previous repairs/UV degradation. Vessels passenger count was reduced to not more than 88 persons on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 15 June 2018
Resolution: Attending Inspector(s) verified installation of two (2) twenty-five (25) person IBA's.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 June 2018 Resolved
Vessel required to carry serviceable life floats for 100% of persons on board. Four life floats were found in need of significant repair (outer coating, retro-reflective markings, pendants, grab lines).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 15 June 2018
Resolution: Attending Inspector(s) verified repairs made IWO life floats.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2018 Resolved
Vessel required to have peripheral rail courses in place. Upper deck peripheral railings were missing a rail course (wire rope).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 15 June 2018
Resolution: Attending Inspector(s) verified repairs/corrections made IWO upper deck rail course.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 June 2018 Resolved
Vessel required to carry current/up to date marine charts for areas transited. Vessel failed to provide/carry current/up to date charts for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 December 2018
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 June 2018 Resolved
Vessel's VHF-FM radiotelephones are required to be programmed with MMSI # in order to be DSC compliant. Vessels VHF-FM marine radio(s) were not properly programmed with vessels MMSI #.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified programming of VHF-FM radio-telephone with MMSI ID.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2018 Resolved
Vessel required to provide/carry devices to conduct alcohol tseting following a Serious Marine Incident (SMI). Vessel failed to carry/provide means to conduct required alcohol testing following a SMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified carriage of alcohol testing devices following a SMI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2018 Resolved
Electrical junction boxes are required to provided with a suitable cover. Electrical cover for junction box/switch outside of shower on bridge was found fractured/broken exposing electrical conductors/connections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 15 June 2018
Resolution: Attending Inspector(s) verified installation of replacement electrical cover for switch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2018 Resolved
Vessel required to carry proper qty of serviceable ring life buoys. Vessels ring life buoy outside of pilothouse (starboard side) was found in need of repalacement due to unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 6 June 2018
Resolution: Attending Inspector(s) witnessed the removal of existing ring life buoy. Vessel has an adequate supply of ring life buoy's installed on board.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 June 2018 Resolved
Vessel's emergency exits are required to be marked properly. Vessels emergency escape's were not properly identified/marked with signage (Emergency Exit Keep Clear).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 6 June 2018
Resolution: Attending Inspector(s) verified installation of proper markings for emergency escape(s).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2018 Resolved
Vessels emergency fuel shut off valves are required to be marked for identificaion and operating instructions. Vessels emergency fuel shut-off valves were not properly marked with equipment serviced and operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified markings for emergency fuel shut off valves.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 June 2018 Resolved
Vessels watertight hatches are required to be marked properly. Vessels watertight hatch IWO lazarette was not marked properly (WATERTIGHT HATCH KEEP CLOSED).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified markings for watertight hatch IWO lazarette (main deck).
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 June 2018 Resolved
Vessel is required to have stop valves installed in way of fire stations. Stop valve IWO port fire station (main deck) was stiff/hard to cycle (requires maintenance).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified installation of shut off valve IWO port main deck fire station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2018 Resolved
Vessel is required to be fitted with bilge high water alarms. Vessels high water (bilge) alarm fitted in the Forepeak was found inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) peformed operational test of the forepeak high water alarm, test sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 June 2018 Resolved
Vessel required to be fitted with ventilation closures for fixed fire extinguishing systems (CO2). Main ventilation closure IWO machinery space entrance (overhead) was not properly fitted/sealed to prevent the escape of fire extinguishing agent.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) performed a visual inspection and operational test of the ventilation closure device for machinery space ventilation system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2018 Resolved
Vessels auxiliary systems are required to meet Sub-F (Engineering). Vessels freshwater pump installation IWO starboard machinery space was not properly secured/mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified mounting of fresh water pump IWO starboard machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2018 Resolved
Vessels flexible hose installations are required to meet Sub-F (Engineering). Vessels flexible hose connections for the main diesel engines IWO machinery space were found in need of replacement due to corrosion/wear/fatigue.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified renewal of all flexible hose connections (where marked).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2018 Resolved
Vessels battery boxes are required to prevent shifting/movement of batteries. Vessels battery box IWO centerline ships service generator was found fractured/deteriorated (required replacement).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified repairs made IWO battery box (outboard, centerline machinery space)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2018 Resolved
Vessel's rotating machinery is required to be protected by guards. Vessels port main diesel engine belt drive assembly was not protected with a suitable/properly installed guard/assembly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 November 2018
Resolution: Attending Inspector(s) verified repairs/adjustments to guard IWO port ships service generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2018 Resolved
Vessels is required to be equipped with two bilge pumps. Vessels secondary bilge pump driven off of the centerline main diesel engine was not capable of drawing suction via the bilge manifold.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 15 June 2018
Resolution: Attending Inspector(s) verified repairs made to secondary bilge pump (engine driven). Performed satisfactory operational test.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 May 2018 Resolved
Replace/secure electrical cover at entrance to engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 May 2018 Resolved
Repair loose/cracked handrails on 01 Deck
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 June 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Stability › Weathertight Integrity › General
Issued 24 May 2018 Resolved
Replace safety glass on pilot house several broken windows.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2018
Resolved 16 May 2019
Resolution: Attending Inspsector(s) verified replacement of safety glass IWO pilothouse.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 May 2018 Resolved
Replace a/c deck ladder and secure ladder to deck. ladder is leading to life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Accommodation/Occupational Safety › Ventilation › General
Issued 24 May 2018 Resolved
Tank room vent STBD aft has furring, grind and seal.
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 14 November 2019
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 24 May 2018 Resolved
In the Laz. Several exhaust hose clamps loose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 May 2018 Resolved
Provide servicing for installed CO2 system. Out of date
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 24 May 2018 Resolved
STBD and center engine mounts loose. Tighten all engine mounts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Communications › Radio Communications › EPIRB
Issued 24 May 2018 Resolved
EPRIB hydro expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 24 May 2018 Resolved
Upper deck safety wire rope is broken and damaged, 2nd deck aft port.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Construction/Loadline › Hull › Hull Plating
Issued 24 May 2018 Resolved
Fore peak compartment; must submit repair plan to CG to address Rot on port frames #2 and #4 and side shell plywood near clamp. Also replace #2 stbd frame to be provided credit drydock to be completed by the end of Nov 2018 as per owners request.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 28 January 2020
Resolution: Repairs completed during DD @ SEC NC.
Lifesaving › Lifefloat › Serviceable
Issued 24 May 2018 Resolved
Replace netting on life float and refasten to deck on weak link.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 12 June 2018
Resolution: Verified satisfactory by the attending M/I
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 January 2018 Resolved
02 deck light lense missing. 02 deck aft of pilot house on top of false stack.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2018
Resolved 16 May 2019
Resolution: Attending Inspector(s) verified installation of deck light lens (02 deck).
Lifesaving › Lifefloat › Serviceable
Issued 6 April 2017 Resolved
Lifefloat outer jacket/covering requires repairs (UV deterioration/cracking).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified repairs made to life float outer coverings.
Lifesaving › Lifefloat › Paddle
Issued 6 April 2017 Resolved
Lifefloat paddles not marked with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 7 April 2017
Resolution: Attending Inspector verified markings on lifefloat paddles.
Lifesaving › Lifefloat › Float-free Link
Issued 6 April 2017 Resolved
Float free link undersized for lifefloat arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of proper type/size of weak links for life float arrangements.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 April 2017 Resolved
Floating waterlight for port lifefloat arrangement inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation/operation of floating water light for life float arrangement.
Lifesaving › Lifefloat › Pendant
Issued 6 April 2017 Resolved
Lifefloat pendants deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified repairs made to life float pendants.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 April 2017 Resolved
Vessel does not carry device(s)/testing equipment for conducting alcohol testing.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified carriage of alcohol testing device/strips.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 April 2017 Resolved
Vessels Not Under Command (N.U.C.) lights are not hardwired.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified electrical installation for navigation lights (NUC).
Engineering › Bilge Water Management System › Not Operational
Issued 6 April 2017 Resolved
Vessels fixed bilge system failed to obtain suction from spaces served.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2017
Resolved 7 April 2017
Resolution: Attending Inspector verified repairs made to fixed bilge system. Performed operational test from all spaces served, test sat.
Construction/Loadline › Hull › Side Shell
Issued 6 April 2017 Resolved
Side shell framing IWO Forepeak (#5 port & starboard) were fractured)
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 12 December 2017
Resolution: Attending Inspector verified repairs made IWO port/starboard frame #5 (forepeak).
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2017 Resolved
Remove portable extension cord powering deep freezer in way of rod room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 7 April 2017
Resolution: Attending Inspector verified electrical installation for freezer installation.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 April 2017 Resolved
Watertight bulkhead penetrations in way of aft rod room are not watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 17 May 2017
Resolution: Attending Inspector witnessed repairs made to aft rod room watertight bulkhead.
Engineering › Bilge Water Management System › Piping
Issued 6 April 2017 Resolved
Fixed bilge piping in way of storage room not properly secured (broken brackets).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of brackets for fixed bilge piping in way of rod room.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 April 2017 Resolved
Remove dead ended wiring in way of storage room watertight bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 17 May 2017
Resolution: Attending Inspector witnessed repairs made in way of storage room watertight bulkhead.
Documentation › Markings/Placards › Warning Signs
Issued 6 April 2017 Resolved
Emergency escape routes/doors not properly marked.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installatin of emergency escape signage.
Documentation › Markings/Placards › Warning Signs
Issued 6 April 2017 Resolved
Main deck watertight hatches not marked properly.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of main deck hatch markings.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 April 2017 Resolved
Ventilation closures for fixed CO2 system (machinery space) deteriorated/not vapor tight.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector witnessed repairs made to main deck ventilation closures.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 6 April 2017 Resolved
Vent pipe for fuel oil storage system not equipped with proper type/style of flame screen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 7 April 2017
Resolution: Attending Inspector verified installation of proper type of flame screen (30" x 30" mesh).
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 April 2017 Resolved
Battery installation in way of machinery space not blocked to prevent movement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 17 May 2017
Resolution: Attending Inspector verified installation of wooden blocks in way of battery boxes located in machinery space.
Engineering › Fuel Oil Service System › Filter
Issued 6 April 2017 Resolved
Primary fuel filter missing flame impingiment bowl assembly as per manufcturers instructions/approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 25 April 2017
Resolution: Attending Inspector verified installation of flame impingiment bowl assembly on port fuel filter/separator.

Casualty record · 3

25 April 2009Routine · role: Involved in a Marine Casualty · activity 3467091
25 April 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3486337
5 September 2009Routine · role: Involved in a Marine Casualty · activity 3617784
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.