13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
The vessel center shaft sheared off and the vessel lost the center propeller.
Replace center shaft and propeller.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Center shaft and prop were replaced with new gear, no vibrations were detected at the sea trail.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 April 2026
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel.
All the inflatable rafts were found with the painters attached to the shackle directly to the vessel and not to the weak-link.
Action required: 10 - Deficiency Rectified
Resolved 22 April 2026
Resolution: Conducted training with the vessel crew and had them attach the painters to the correct place on the Hammar HRU, through the red eye on the HRU unitm through the weak-link.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 2 May 2024
Resolved
A vessel which, complies with requirements in subchapter S of this chapter, must have stability details on the vessel's Certificate of Inspection, a stability letter issued by the cognizant Officer in Charge, Marine Inspection (OCMI) or the Commanding Officer, Marine Safety Center
An Inclining Experiment was performed on 02MAY24 after the vessel was re-powered at the last shipyard period in April 2024 - MISLE - 7848036. The vessel's current Stability Letter dated 01DEC11 allowed for the carriage of 114 Total Persons.
Vessel's passenger count is restricted to 53 Total Persons (50 Passengers and 3 Crew) with zero (0) passengers allowed on the upper deck, until fixed ballast is installed and the new Stability Letter is issued by the Marine Safety Center.
Action required: 705 - Other - as specified
Resolved 18 July 2024
Resolution: 5LT of ballast was installed in accordance with the Stability and Lightship Characteristics letter and stability letter issued 16JUN24. A maximum of 25 persons may be carried on the second deck.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 April 2024
Resolved
A vessel which, under 46 CFR 178.310 complies with requirements in Subchapter S of 46 CFR, must have stability details on the vessel COI or stability letter issued by the Marine Safety Center. During a recent dry dock period the vessel has undergone numerous modifications resulting in a significant weight change and therefore must conduct a new stability test, prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2024
Resolved 2 May 2024
Resolution: An Inclining Experiment was performed on 02MAY24. Vessel's passenger count is restricted to 53 Total Persons (50 Passengers and 3 Crew) until the new Stability Letter is issued by the Marine Safety Center.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 February 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs; Vessel's center strut tube is cracked on forward edge. Blast strut and shaft log for inspection of all welds.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2023
Resolution: Repairs sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2023
Resolved
The marine inspector may conduct a visual examination and may require nondestructive testing of the propeller shafting whenever the condition of shafting is in question; shaft is damaged and must be renewed along w/ cutlass bearing.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2023
Resolution: Shaft and both bearings renewed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2022
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel operating with 03 deficiencies open past due date
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: All deficencies were corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2022
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). 2 fixed power pumps of 50 GPM
Bilge pumping arrangement was not operational or of sufficient capacity.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2022
Resolution: Conducted satisfactory bilge function test utilizing both bilge pumps witnessed by [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 April 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space.
Bilge high water alarm worked intermittently.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 2 June 2022
Resolution: Bilge alarm float switch replaced, tested satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 April 2022
Resolved
A hatch exposed to the weather must be watertight.
Fore peak and generator space failed hose test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 2 June 2022
Resolution: Repairs were made to both hatches and passed hose test.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2022
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 2 June 2022
Resolution: Metal trash cans were placed in service.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2022
Resolved
Except as otherwise provided in this section, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape, one of which must not be a watertight door.
Marked escape hatch from rod storage room was blocked by a rug. hatch was freed up and rug removed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: hatch was freed up and rug removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 April 2022
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter.
14 life jacket lights were extinguished. Batteries were replaced and made operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Batteries were replaced and made operational.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 November 2021
Resolved
Vessel required to be equipped with an operable fire pump. Existing fire pump control box located in the engine room requires repair/replacement due to worn (internal) components (contacts)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2021
Resolved 2 March 2022
Resolution: New motor controller was installed and fire pump motor was tested while on dock.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 October 2021
Resolved
Vessel's EPIRB required to be registered with NOAA on an Annual basis. Existing EPIRB regisration has expired.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2021
Resolved
Vessel required to be equipped with serviceable life saving equipment. Existing life floats require maintenance/repair to its main body (paint/markings/retro-reflective markings), netting, painter lines, and peripheral pendants.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2021
Resolved
Vessels required to be equipped with two paddles for each life float. Existing paddles require replacement due to UV deterioration/degradation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 October 2021
Resolved
Vessels portable fire extinguishers require annual servicing. Existing portable fire extinguishers are expired/require annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 October 2021
Resolved
Vessels lower deck hatch/access covers are required to be made watertight. Existing hatch/access covers IWO fwd storeroom & (old) crew quarters/rod room are not secured/watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 October 2021
Resolved
Vessel required to be equipped with a fixed bilge system capable of dewatering any compartment. Existing fixed bilge system is not capable of drawing suction from the fwd voids of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2021
Resolved
Vessel required to be equipped with emergency fuel shut-off valves. Existing fuel shut off valve reach rod IWO port engine room requires repair/(re)connecting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 16 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 October 2021
Resolved
Vessel's main deck (exterior) hatches are required to be made watertight. Existing hatch for lazarette is damaged/not allowing hatch to seal effectively.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 2 March 2022
Resolution: New dogging mechanisim was installed; test sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2021
Resolved
Flexible hoses in vital systems are required to be secured with at least two clamps. Existing shaft log is missing securing clamps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021
Resolved 2 March 2022
Resolution: hose clamp was added to flexible hose on shaft seal
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2020
Resolved
Type I PFD's are required to be equipped with PFD lights. Five (05) child sized PFD lights were extinguished/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2020
Resolved 5 March 2021
Resolution: Attending Inspector(s) verified renewal of PFD lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2020
Resolved
Vessels pressure vessels are required to be fitted with relief valves. Starboard air receiver's relief valve was seized shut and was not capable of being hand lifted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2020
Resolved 5 March 2021
Resolution: Attending Inspector(s) verified operation of air receiver relief valves.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 November 2020
Resolved
Vessels required to be fitted with emergency/remote fuel shut off valves. Existing universal joints for port reach rod assembly were found worn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2020
Resolved 5 March 2021
Resolution: Attending Inspector(s) verified replacement of universal joint connections for emergency fuel shut-off reach rod valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2020
Resolved
Vessel required to be equipped with a suitable steering system. Port tiller arm IWO lazarette requires repair/machining to ensure proper fit for rudder post.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2020
Resolved 8 April 2021
Resolution: Attending Inspector(s) verified repairs made IWO port tiller arm.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 November 2020
Resolved
Vessels DSC equipped radio-telephones are required to be programmed with vessel particulars. Existing VHF-FM radiotelephone is not properly programmed with (current) MMSI #.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2020
Resolved 19 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 November 2020
Resolved
Vessel required to be equipped with Class A AIS. Existing Class A AIS unit is not properly programmed with MMSI #.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2020
Resolved 19 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 November 2020
Resolved
Vessel required to be equipped with a fire main system. Existing ball valve handles for port & starboard fire stations along main deck are wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2020
Resolved 8 April 2021
Resolution: Attending Inspector(s) verified repairs made to main deck fire station valve handles.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 October 2020
Resolved
No major repairs or alterations affecting the safety of the vessel with regards to hull, machinery, or equipment shall be made without the knowledge and approval of the cognizant [name withheld] conducting an interal inspection of the port main diesel engine bay, attending Inspector called out fractured weldments IWO bottom longitudinal framing at aft transverse framing. Temporary repairs are authorized until next scheduled hull examination scheduled for 28FEB2022.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 2 March 2022
Resolution: Bottom long was strengthend and gussets added under port engine
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2019
Resolved
Vessels lifesaving equipment is required to be marked with retro-reflective markings. Vessels retro-reflective markings IWO life floats were worn/deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified life float markings.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 November 2019
Resolved
Floating water light batteries are required to be renewed annually. Vessels life float batteries were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified float battery installations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 November 2019
Resolved
Each vessel that opeates on the high seas must have on board an FCC Type Accepted Cat. 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels hydro-static release unit (HRU) was found expired (beyond service life).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2020
Resolution: New hydrostatic release installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2019
Resolved
Each life float must be equipped with paddles (min. 4') and be lashed to life float to which it belongs to and must be buoyant. Vessels paddles IWO life floats were found cracked/checked/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 November 2019
Resolved
Vessel must be equipped with an operable MF/HF radio-telephone if operated beyond between 20nm & 100 nm. Vessels microphone for radio-telephone was deteriorated/required repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified replacement of microphone/cord for SSB radio-telephone.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 25 November 2019
Resolved
Vessel is required to be fitted with a suitable magnetic compass and must be illuminated. Vessels magnetic compass was not illuminated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified operation/illumination of compass.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2019
Resolved
Vessel is required to be equipped with navigational lights. Vessel's not under command (NUC) lights are not properly wired/configured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified wiring/operation of navigational lights (NUC).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 November 2019
Resolved
Vessels watertight hatches are required to be marked "WATERTIGHT HATCH KEEP CLOSED". The watertight hatch IWO lazarette is missing required markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified hatch markings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 November 2019
Resolved
Vessels emergency escape hatches/scuttles are required to be marked "EMERGENCY ESCAPE KEEP CLEAR". Vessels emergency escape hatch/scuttle IWO crew quarters/accomodations is not marked on the exterior/top.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified hatch markings.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 November 2019
Resolved
Vessel is required to be fitted with emergency fuel shut-off valves, properly installed/marked to indicate operation. Vessels emergency fuel shut-off valves were not marked with direction of operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 25 November 2019
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Vessels lighting fixture IWO serving area (above refrigerator) was found fractured/broken.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified repairs made to lighting fixture.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 November 2019
Resolved
Each fire nozzle must be of a corrosion resistant material and be capable of being changed between a solid stream and spray pattern. Vessels fire nozzle(s) were of the proper type/style, however, the nozzle were seized in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2019
Resolved
Vessel must be equipped with batteries of adequate capacity to supply the loads for three hours. Vessels emergency communications battery IWO fwd storeroom has excessive ring terminals installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified removal of excessive ring terminals IWO emergency battery.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2019
Resolved
Each distribution panel must be totally enclosed and be of the dead front type. Vessels panelboard IWO fwd storeroom is not installed properly (missing labels/markings to indicate service).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 November 2019
Resolved
Vessel required to be equipped with watertight bulkheads. Vessels watertight bulkhead IWO fwd. crew accomodations has a bulkhead penetration that is not considered watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 November 2019
Resolved
Vessel required to be equipped with watertight hatches/covers. Vessels hatch IWO fwd crew quarters/accomodations space is not equipped with securing hardware/gasketing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified repairs made IWO fwd crew quarters hatch.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 25 November 2019
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Vessels lighting fixture IWO crew quarters/accomodations space was found fractured/broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified repairs made to lighting fixture.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 November 2019
Resolved
Vessel required to be fitted with watertight hatches/scuttles. During operational test of watertight hatch IWO lazarette, attending Inspector(s) noted that the hatch would not fully seal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 November 2019
Resolved
Vessels auxiliary machinery is required to be equipped with an operable temperature gauge. Vessels port SSDG temperature gauges was found faulty/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2019
Resolved
Vessel is required to be capable of dewatering any compartment. Vessels electric submersible bilge pump IWO lazarette failed to operated when tested.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified operation of electric submersible bilge pump IWO lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2019
Resolved
Vessel must be equipped with a main steering gear that is of adequate strength. Excessive play was noted IWO port rudder post/tiller arm (keyway), port & stbd tiller arm connections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 25 November 2019
Resolved
Vessel's electrical conductors are required to be secured every 24" via metal supports. Electrical conductors IWO crew quarters/accomodations (overhead) are not properly secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified installation of securing devices for electrical conductors IWO crew quarters (overhead).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 November 2019
Resolved
Vessel required to be equipped with watertight hatches/covers. Vessels hatch IWO fwd storeroom space is not equipped with securing hardware/gasketing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified repairs made IWO fwd storeroom watertight hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2019
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw down valve on the fwd side of the collision bulkhead and operable from the weather deck. Vessels screw down valve IWO forepeak was seized in the open position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 28 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 November 2019
Resolved
Vessels fire pump is required to be equipped with a pressure gauge. Vessels fire pump pressure gauge was found inoperable during testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified installation of pressure gauge IWO fire pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2019
Resolved
Vessels emergency escape hatches are required to be marked IAW 46 CFR 185.606. The emergency escape hatch for the overnight accomodations space was not marked (main deck side).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 10 January 2020
Resolution: Attending Inspector(s) verified hatch markings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2019
Resolved
Vessels overnight accomodations space(s) accessible to crew on a regular basis must have at least two means of escape. The secondary means of escape (hatch) was found siliconed down to prevent water intrusion from fresh water washdowns.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified removal of silicone IWO emergency escape hatch. Performed satisfactory operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2019
Resolved
Each door, hatch or scuttle used as a means of escape but be capable of being operated by one person, from either side, in both light and dark conditions. Handles and securing devices must be permanently installed and not capable of being easily removed. The emergency escape hatch for the overnight accomodations space was not equipped with a dogging handle inside the space.
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of dogging wrench for fwd emergency escape hatch IWO crew quarters.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2019
Resolved
The operation of all weathertight closures above the weather deck shall be inspected a t each initial and subsequent inspections for certification. Attending Inspector noted that the secondary means of escape (watertight hatch) from the overnight passenger accomodations was not seated/adjusted properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified adjustments made to emergency escape hatch. Performed satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 October 2019
Resolved
All portable/semi-portable fire extinguishing equipment shall be in a serviceable condition at all times. Attending Inspector noted that the B-II extinguisher located in the overnight accomodations space was damaged (upper handle) and required servicing/repair/replacement.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified installation of (new) portable fire extinguisher IWO crew quarters.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 October 2019
Resolved
Vessels overnight accomodations shall be fitted with an independent modular smoke detector IAW 46 CFR 181.450. Vessels overnight accomodations space was missing the required smoke type/style smoke detector.
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 25 November 2019
Resolution: Attending Inspector(s) verified the installation of proper type/qty of modular smoke detector IWO crew quarters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2019
Resolved
Starboard main diesel engine experienced a catastrophic failure of the connecting rod IWO cylinder #6.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2019
Resolution: Attending Inspector verfified the installation of a (remanufactured) main diesel engine (stbd).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2018
Resolved
Dead ended wiring noted IWO helm/operating station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified removal of dead ended wiring IWO operator's station/helm.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 November 2018
Resolved
Fractured weldments for weighted ring on life float (starboard side, top float)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified repairs to weighted rings in way of life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 November 2018
Resolved
Peripheral grab line around life floats were found deteriorated (by UV light).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified repairs made to peripheral grab lines in way of life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 November 2018
Resolved
Paddles for life floats were found deteriorated/damaged beyond repair and not tethered properly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified renewal of paddles for life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 November 2018
Resolved
Lifefloat installation was missing spacers between each float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified installation of spacers between life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 November 2018
Resolved
Life float outer coverings damaged/holed/torn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified repairs to outer coverings for life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 November 2018
Resolved
Weak links for life float installations were not properly marked/identified with manufacturers tags.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 November 2018
Resolved
Ship's whistle was inoperable at time of inspection (require repair/repalacement).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified repairs made IWO ships whistle. Performed satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2018
Resolved
Fire nozzles were found damaged/required repair. Rubber cone around nozzle was fractured which prevented the user to adjust the pattern of the nozzles.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified installation of (new) fire nozzles.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 November 2018
Resolved
Watertight door for machinery space was fractured/wasted @ upper/lower hinges.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified repairs made IWO exterior watertight door for machinery space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 November 2018
Resolved
Watertight door gasket IWO machinery space exterior door was cracked/imroperly installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified repairs made IWO exterior watertight door for machinery space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2018
Resolved
Type I PFD water lights were inoperable at time of inpsection (dead batteries).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified installation/operation of water lights for Type I PFD's carried on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2018
Resolved
Upper deck PFD stowage was missing two child sized Type I PFD's
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified the carriage of proper type/qty of child sized Type I PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2018
Resolved
Ring life buoys markings were faded/required repalcement (retro-reflective markings).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 3 April 2019
Resolution: Attending Inspector verified renewal of ring life buoy markings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2018
Resolved
Open junction box cover IWO port upper pilothouse (former lighting connection).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified renewal of junction box IWO port upper pilothouse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2018
Resolved
Fractured junction box IWO upper deck (overhang)aft of pilothouse, port side.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified renewal of junction box IWO port side upper deck, aft of pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2018
Resolved
Upper deck PFD stowage locations are missing donning instructions/placards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified posting of PFD donning instructions IWO upper deck stowage boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 November 2018
Resolved
Upper deck lighting fixture cover was fractured/broken, requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified renewal of lighting fixture IWO upper deck overhang.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2018
Resolved
Junction box IWO port quarter lazarette missing splash cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified renewal of splash cover IWO junctin box cover IWO lazarette.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 November 2018
Resolved
Fwd storeroom watertight deck cover was unsecured (unbolted) and missing gasket material (non-watertight).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified installation of harware for main deck watertight cover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 November 2018
Resolved
Crew quarters watertight deck cover was unsecured (unbolted) and missing gasket material (non-watertight).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified installation of harware for main deck watertight cover.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 November 2018
Resolved
Emergency fuel shut-off reach rod assembly (starboard) missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified repairs made IWO port main diesel engine reach rod assembly. Performed satisfactory operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2018
Resolved
Flexible hose assemblies for primary fuel fill(s) were not properly secured (double hose clamps).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 14 November 2019
Resolution: Attending Inspector verified installation of double hose clamps IWO fuel fill piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 November 2018
Resolved
Starboard ships service diesel generator missing guard for rotating machinery IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified installation of guard for rotating machinery (crank shaft accessory drive).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2018
Resolved
Owner/operator to provide operating instructions for fixed bilge/fire systems (in writing). Once vetted, instructions to be posted in machinery space for crews use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 18 December 2018
Resolution: Attending Inspector(s) verified posting of operating instructions for vessels fixed bilge system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2018
Resolved
Fractured weldments noted IWO starboard frame (lower) of POTW tank (lazarette).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 17 December 2019
Resolution: Attending Inspector verified repairs made to POTW structure (lazarette).
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 November 2018
Resolved
Crew quarters missing approved smoke detector (overnight accomodations).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 22 May 2019
Resolution: Attending Inspectors verified installation/approval data for portable smoke detector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2018
Resolved
Missing two portable lights on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 22 May 2019
Resolution: Attending Inspector verified carriage of two portable lights on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2018
Resolved
Dye pen welds(by qualified party) port, center, and stbd shaft logs to prove welds.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 2 August 2018
Resolution: Owner and shipyard welders provided a statement of fitness for shaft logs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2018
Resolved
Provide proof of welds/repairs to port side strut tube. To be completed prior to current hull exam.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 2 August 2018
Resolution: Provided statement of fitness from owner and shipyard welders.
Engineering › Bilge Water Management System › Pump
Issued 15 December 2017
Resolved
Provide proper type/size of fixed bilge pump IWO starboard machinery space. *Existing pump does not have the capacity to dewater all spaces served. **Following repairs, perform operational test of fixed bilge system from all spaces served with both pumps.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2018
Resolved 20 April 2018
Resolution: Attending Inspector(s) performed operational test of fixed bilge system. Test sat.
Construction/Loadline › Structures › Deck Plating
Issued 12 December 2017
Resolved
Crop/renew wasted deck plating IWO starboard quarter main deck (@ deck fill). *Temp repairs currently in place.
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 18 April 2018
Resolution: Deck was cropped and renewed to remove temp repair.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 August 2017
Resolved
Temporary repairs were made to aft watertight bulkhead of crew accomodations space (@ bottom of ladder) without USCG oversight.
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 18 April 2018
Resolution: Cropped and renewed fuel tank bulkhead at base of ladder.
Engineering › Fuel Oil Service System › Piping
Issued 28 August 2017
Resolved
Active fuel leaks IWO machinery space (below deck plates, centerline/aft) for SSDG supply/return.
Action required: 705 - Other - as specified
Resolved 22 September 2017
Resolution: Attending Inspectors verified corrections/adjustments made IWO fuel oil supply/return flexible fuel lines located in the machinery space (aft/centerline).
Lifesaving › Lifefloat › Pendant
Issued 28 August 2017
Resolved
Life float pendants were deteriorated/UV damaged, required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector verified repairs made to life float pendants (replaced where required due to UV deterioration).
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 August 2017
Resolved
Improper type of batteries installed in floating waterlights (life floats & ring buoys)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 25 October 2017
Resolution: Attending Inspector(s) verified installation of proper type of batteries for floating waterlights.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 August 2017
Resolved
EAP (policy) & hotline numbers not carried/posted on board.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified current/up to date consortium roster (Maritime Consortium).
Navigation › Piloting/Steering › Marine Charts
Issued 28 August 2017
Resolved
Vessel did not carry current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 25 October 2017
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 August 2017
Resolved
Vessel did not carry proper quantity of child sized PFD's as per COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2017
Resolution: Attending Inspector(s) verified carriage of proper type/size of Type I PFD's (child sized).
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 August 2017
Resolved
Vessel did not carry current/up to date navigation publications for areas transited.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified carriage of current/up to date navigation publications for areas transited.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 August 2017
Resolved
Vessels VHF-FM radio's were not programmed with MMSI #.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2018
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified installation/programming of VHF-FM marine radio (DSC equipped/MMSI #).
Documentation › Markings/Placards › Warning Signs
Issued 28 August 2017
Resolved
Vessels main deck watertight hatches were not properly marked.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified presence of watertight hatch markings.
Documentation › Markings/Placards › Warning Signs
Issued 28 August 2017
Resolved
Vessels emergency escape routes were not properly marked.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 31 August 2017
Resolution: Attending Inspector(s) verified the posting of emergency exit signage along the main deck of the vessel.
Stability › Watertight Integrity › General
Issued 28 August 2017
Resolved
Machinery space exterior door gasket missing/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 12 December 2017
Resolution: Attending Inspector verified installation of proper type/size of gasketing material in way of machinery space watertight door.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 August 2017
Resolved
Provide operating instructions for remote fuel shut-off valves.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 31 August 2017
Resolution: Attending Inspector(s) verified the posting of operating instructions for remote/emergency fuel shutoff valves.
Communications › Audible Communications › Horn/Whistle
Issued 28 August 2017
Resolved
Ship's whistle was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector performed operational test of ships whistle, test sat.
Engineering › Bilge Water Management System › Pump
Issued 28 August 2017
Resolved
Electric bilge pump (starboard machinery space) required replacement.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified repairs to starboard bilge pump (electrical breaker) and performed operational test, test sat.
Lifesaving › Lifefloat › Markings
Issued 28 August 2017
Resolved
Renew markings for life floats & associated equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified markings for lifesaving equipment; i.e.: life floats, paddles, etc...
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 August 2017
Resolved
Crew accomodations space missing emergency lighting for means of escape (routes).
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified installation and performed operational test of emergency lighting IWO crew accomodations space.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 August 2017
Resolved
Properly mount 220V outlet box in way of aft machinery space panelboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Attending Inspector(s) verified removal of 220V outlet box from panel board IWO machinery space (aft).
Communications › Alarms/Indicators › High Water Alarm
Issued 28 August 2017
Resolved
Troubleshoot/repair cause of erroneous high water temp alarms for starboard main diesel engine @ operators station.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 22 September 2017
Resolution: Vessels owner/operator advised that all connections for high water temperature sending unit were checked/tightened. Vessel owner/operator performed operational test, test sat.
Engineering › Bilge Water Management System › Manifold
Issued 28 August 2017
Resolved
Isolate/repair leaks in way of fixed bilge manifold (machinery space).
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 15 December 2017
Resolution: Attending Inspectors witnessed repairs made IWO bilge manifold.
Engineering › Bilge Water Management System › Strainer
Issued 25 August 2017
Resolved
Replace wasted bilge suction strainer IWO crew accomodations bilge. *Temp repairs currently in place.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 28 February 2020
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 June 2017
Resolved
Due to the replacement of the center and stbd shafts and associated bearings the operator must perform an alignment to insure the shafts are properly aligned to the engines.
Action required: 705 - Other - as specified
Resolved 8 June 2017
Resolution: Vessels owner hired Crawford's Marine to verify alignment of vessels propulsion shafting. Attending Inspector(s) verified third party report.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 23 May 2017
Resolved
Vessel experiences a unusual vibration while operating in the 1400 RPM (+/-) range as a result of bump/go grounding.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Attending Inspector(s) witnessed operational test following (new) shaft installations.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 June 2016
Resolved
Vessels portable fire extinguishers were out of service dates for annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: Vessels portable extinguishers were taken to local servicing facility for annual testing.
Lifesaving › Hand Flares › Quantity
Issued 10 June 2016
Resolved
Vessel was not equipped with proper quantity of visual distress signals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: Vessel representative purchased required quantity/type of visual distress signals and placed on board.
Documentation › Markings/Placards › Capacity Marking
Issued 10 June 2016
Resolved
Vessel not equipped with markings for upper deck capacity IAW COI (max. 40 passengers).
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified upper deck markings for the carriage of passengers.
Engineering › Bilge Water Management System › Valve
Issued 10 June 2016
Resolved
Reach rod handle for anchor locker/forepeak bilge suction was fractured/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified repairs made to anchor locker/forepeak reach rod handle assembly and performed operational test.
Engineering › Bilge Water Management System › Valve
Issued 10 June 2016
Resolved
During operational test of installed bilge system, suction could not be obtained from forward store room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: Attending Inspectors witnessed repair of a frozen check valve in the bilge piping system. Performed operational test, test sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 June 2016
Resolved
Wiring for 240V outlet located in forward store room (aft bulkhead) showed signs of deterioration/charring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified repairs made to 240V electrical outlet. The outlet was removed from the vessel.
Stability › Watertight Integrity › General
Issued 10 June 2016
Resolved
Attending Inspectors noted a previous sounding tube penetration that was left open between the lower decks of the forward store room and the bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors witnessed installation of a threaded cap on the sounding tube penetration.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 June 2016
Resolved
Forward store room panelboard (aft bulkhead) was missing blanks/inserts for breakers/outer panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors witnessed installation of blanks/inserts IWO panel board.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 June 2016
Resolved
The starboard reach rod assembly for the emergency fuel shut off has a fractured swivel fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors witnessed repairs made to starboard MDE emergency fuel shut off and performed operational test.
Engineering › Fuel Oil Service System › Piping
Issued 10 June 2016
Resolved
Attending Inspectors noted minor fuel leaks IWO MDE F/O returns to tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors witnessed repairs made to F/O system. No leaks were noted.
Engineering › Pressure Vessel › Weld
Issued 10 June 2016
Resolved
Primary air receivers were beyond their inspection dates as prescribed by vessels COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors performed an internal/external inspection of both air receivers (pressure vessels) located in machinery space/engine room.
Fire Fighting › Fire Hoses › Condition
Issued 10 June 2016
Resolved
O-rings in fire hose connections were dry-rotted/deteriorated & required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified installation of new o-rings in both port & starboard fire hoses.
Lifesaving › Lifefloat › Paddle
Issued 10 June 2016
Resolved
Paddles for life floats were in need of repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified the condition of life float paddles.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 June 2016
Resolved
Batteries in floating waterlights required renewal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified the battery status in floating water lights.
Lifesaving › Lifefloat › Serviceable
Issued 10 June 2016
Resolved
Lifefloat exterior coating was in need of repair/re-coating due to UV light (fading).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified repairs made to outer coating of life floats.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 June 2016
Resolved
Vessels emergency fuel shut off valves were not properly marked with operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified markings (operating instructions) for emergency fuel shut-off valves.
Navigation › Piloting/Steering › Marine Charts
Issued 10 June 2016
Resolved
Vessel did not have current/up to date charts for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified status of marine charts carried on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 June 2016
Resolved
Vessel not equipped with current/up to date CG Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified status of navigational publications carried on board.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 June 2016
Resolved
Vessel not equipped with current/up to date tide/current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspectors verified status of navigational publications carried on board vessel.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 10 June 2016
Resolved
Vessels Port fuel oil vent not equipped with flame screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 31 August 2016
Resolution: Attending Inspectors verified installation of flame screen mesh in port fuel vent.
Lifesaving › Lifefloat › Lifeline
Issued 10 June 2016
Resolved
Installed lifelines on lifefloats required repair/replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspector verified repairs made to life float lifelines/pendants.
Lifesaving › Lifefloat › Painter
Issued 10 June 2016
Resolved
Lifefloat painter lines require repair/replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspector verified repairs made to life float painter lines.
Fire Fighting › Nozzles › Type
Issued 10 June 2016
Resolved
Starboard fire station not equipped with proper type of fire nozzle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 11 July 2016
Resolution: Attending Inspector verified proper type of nozzle for port & starboard fire stations.
Navigation › Piloting/Steering › Binnacle
Issued 10 June 2016
Resolved
Verify accuracy of magnetic compass. While conducting drills, attending Inspectors noted that compass card was not rotating when vessel was listing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: Attending Inspectors verified operation and accuracy of vessels magnetic compass.
Communications › Audible Communications › Horn/Whistle
Issued 10 June 2016
Resolved
Vessels horn failed operational test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: Attending Inspectors witnessed repair of vessels horn and performed operational test. Test sat.