07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 June 2025
Resolved
An interconnected detection and alarm system must consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory as meeting UL 217. The detector was not operational even with new batteries installed.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050. The grab line on the existing ring buoy is not properly attached, and the reflective tape is deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2025
Resolved
Each life jacket carried on a vessel on oceans route, must have a life jacket light approved in accordance with 46 CFR 161.012. Eight adult life jackets were missing lights. The vessel is restricted to the carriage of twenty-three total person until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the Inland Navigation Rules. The mast head light and the stern light are not operational, the vessel is restricted to day time operations.
Action required: 705 - Other - as specified
Due 1 July 2025
Resolved 21 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The vessel is only equipped with one light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 June 2025
Resolved
The vessel master, as the primary operator of the VHF radio, is required to have a Marine Radio Operator Permit in accordance with FCC regulation. The master could not provide proof of same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2025
Resolved 13 July 2026
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 June 2025
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up-to-date charts and navigation publications. The vessel is not equipped with the Inland Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2025
Resolved
The marine employer must have a drug testing program in place. The crew list is not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. The placard was not so posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 June 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. The placard is not so posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 June 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 46 CFR 185.510. The log book is miising and proof of training could not be provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 21 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 June 2024
Resolved
Each Lifefloat must meet the specifications in accordance w/approval number 160.027; vessel is restricted to voyages not more than three miles from shore.
Action required: 10 - Deficiency Rectified
Due 18 June 2024
Resolved 18 June 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 June 2024
Resolved
A hatch exposed to the weather must be watertight; STBD outboard ER scuttle mechanismwas seized. Master repaired while MI's were onboard
Action required: 10 - Deficiency Rectified
Due 18 June 2024
Resolved 18 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 June 2024
Resolved
Vessel must be equipped with a means for testing for the presence of alcohol intoxication; vessel's alcohol testing swabs are expired
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 2 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 June 2024
Resolved
A life jacket must be provided for each person on the vessel; vessel is restricted to 28 total persons due to three life jackets being unservicable.
Action required: 705 - Other - as specified
Resolved 19 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 June 2024
Resolved
A vessel on a Oceans route must carry six handheld distress signals and six orange handheld distress signals; vessel is missing 4 day/night flares
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 2 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and for the purpose intended; PORT and STBD exhaust hoses in lazarette are dryrotted and require replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 25 July 2024
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 June 2024
Resolved
IAW 47 CFR 80.903 vessels must have onboard a Safety Radio Certificateissued for not more than 5 years; vessel's current cert. expired in 2022
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 20 September 2024
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 June 2024
Resolved
VHF radio must be installed w/ GPS input and vesel's MMSI programmed. Radio was replaced and was not programmed as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 2 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2024
Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; remove or properly terminate unused deadend wires/cables under lower console
Action required: 705 - Other - as specified
Due 1 July 2024
Resolved 13 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2024
Resolved
An exposed hazard such as rotating machinery must be protected by a cover or guard; Port MDE is missing suitable guard over belts and pulleys.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 25 July 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2024
Resolved
Reomote fuel shuto stations must be marked in clearly legible letters at least 25MM 1" high; vessel's fuel shutoffs were not labled. Master labled while MI's were onboard.
Action required: 10 - Deficiency Rectified
Due 18 June 2024
Resolved 18 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2023
Resolved
An adult life jacket must be carried for every adult on board the vessel; vessel's COI required 31 adult life jackets but vessel has 30 onboard. Vessel is limited to 30 adult pax.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2023
Resolved 13 July 2026
Resolution: Vessel had proper numbers on board at time of inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2023
Resolved
Vessel has inoperable anchor light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2023
Resolved 13 July 2026
Resolution: Vessel demonstrated operation of anchor light.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 March 2022
Resolved
46CFR 184.506: A durable placard must be posted next to all radiotelephone installations with emergency instructions for broadcast; vessel is missing placard
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 5 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 March 2022
Resolved
46CFR 180.71: An adult lifejacket must be provided for all persons onboard; 01 lifejacket is waterlogged and cannot be used
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 March 2022
Resolved 21 March 2022
Resolution: Owner placed new jacket onboard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 March 2022
Resolved
46 CFR 179.360: A hatch esposed to the weatherdeck must be watertight; all round plastic hatches on weatherdeck are cracked; replace all cracked hatches
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 20 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2022
Resolved
Repair leaking helm seal on steering wheel on flybridge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 March 2022
Resolved 21 March 2022
Resolution: Master replaced seal while MI was onboard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 September 2021
Resolved
A penetration in a watertight bulkhead must be as high up as possible and made watertight; several penetrations in fwd/aft bulkhead in ER are not watertight.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2021
Resolution: Attending Inspector received objective evidence of corrections made to forward watertight bulkhead/main deck penetrations.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 September 2021
Resolved
Life floats must be equipped with a floating waterlight. Existing floating water light (stbd) was found extinguished (dead battery).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2021
Resolved 17 September 2021
Resolution: O/O replaced battery
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 June 2021
Resolved
provisions must be made to close all supply ducts and exhaust duct discharge openings for a space protected by a fixed extinguishing system; water wash down pipe on port side is not airtight where it passes from main deck to ER and vent trunk on port side is deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 September 2021
Resolution: Attending Inspector verified corrections made to main deck @ water wash down flexible hose & ventilation trunk.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 June 2021
Resolved
A penetration in a watertight bulkhead must be as high up as possible and made watertight; several penetrations in fwd and aft bulkheads in ER are not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 September 2021
Resolution: Attending Inspector verified corrections made to bulkhead penetrations IWO machinery space.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 June 2021
Resolved
A vessel must carry a first aid kit w/ approval 160.041, or a kit w/ and equivalent contents; vessel first aid kit is missing items and not labeled IAW 184.710 “ FIRST AID KIT”
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 September 2021
Resolution: Attending Inspector verified renewal of expired items & marking of first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2021
Resolved
A life jacket must be provided for each person a vessel is authorized to carry as indicated on the COI; 02 Childs and 03 Adult PFD’s are missing
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 September 2021
Resolution: Attending Inspector verified carriage of proper type/qty of PFD's.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2021
Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; numerous dead end wires under the main deck operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 September 2021
Resolution: Attending Inspector verified removal of dead ended wiring IWO console.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2020
Resolved
A lifejacket must be provided for each person the vessel is authorized to carry as indicated on the COI; twelve (12) lifejackets were found deteriorated and no longer serviceable. The vessel is restricted to eighteen (18) total persons until the full compliment of lifejackets is restored.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2020
Resolved
The vessel must be provided with bilge pumps IAW Table 46 CFR 182.520 (a) or IAW 46 CFR 182.520 (e); the discharge hose for the engine compartment bilge pump is deteriorated and longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 June 2020
Resolved
A hatch exposed to the weather must be watertight; the gasket on the port watertight hatch is deteriorated and needs to be renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2020
Resolved
In systems and applications where flexible hoses are permitted, double hose clamping is required where practicable; a hose clamp is missing from the port exhaust piping system in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2020
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 23 June 2020
Resolved
The GPS must be configured to provide data input to the VHF radio for proper function of the DSC function of the radio; the GPS is not connected to the VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 23 June 2020
Resolved
The vessel must be fitted with a radar if it is self-propelled, on an oceans route, and carries more than 49 passengers; although not required by regulation this vessel is so equipped, however the radar is not functional, the radar must be replaced or removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2020
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 June 2020
Resolved
When in accordance with 178.210 the vessel must be provided with a stability letter, the stability letter must be posted under transparent material at the operating station; the Captain was unable produce a copy of the stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 June 2020
Resolved
A vessel must carry adequate and up-to-date navigation publications for the intended route; the vessel is not provided with the tide tables, current tables, and notice to mariners.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2020
Resolved
The pre-engineered fixed fire extinguishing system must automatically shut down all engines within the protected space; during an operational test the system did not shut down the port main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2020
Resolution: Repairs made prior to MI departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 May 2020
Resolved
Gauges to indicate engine lube oil pressure must be provided for all propulsion engines, the gauges must be readily visible at the operating station; the port main engine lube oil pressure gauge is not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2020
Resolved
Fuses must be of the cartridge type only and be listed by UL; the new fuse block installed under the operating station console is a blade type fuse block.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 7 June 2019
Resolved
The Master of the vessel is required to have an FCC Radio Operator Permit, provide proof of same.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 7 June 2019
Resolved
The vessel does not have a current waste management plan, provide a plan endorsed by the Master.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 July 2019
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 June 2019
Resolved
The bilge alarm does not emit an audible alarm loud enough to be heard under operating conditions; repair or replace the as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2019
Resolution: This item corrected prior to MI's departure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 June 2019
Resolved
The forward mast light and the stern light are not operational; repair or replace as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 June 2019
Resolved
The life float is not properly marked with reflective tape; replace the reflective tape with an approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2019
Resolved
Numerous lifejackets have deteriorated reflective tape, replace the reflective tape as needed. The vessel is limited to the carriage of 22 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2019
Resolved
Several lifejacket lights are not working or missing, repair/replace/provide lights as needed. The vessel is limited to the carriage of 22 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2019
Resolved
Numerous life jackets are deteriorated and have been condemned, replace lifejackets as needed for full compliment of 31. The vessel is limited to the carriage of 22 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2019
Resolved
The first aid kit is not adequately stocked with proper inventory, provide for missing items as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2019
Resolved
The waste drain pipe from the port turbo is deteriorated and damaged due to improper installation of the hose clamp, repair or replace as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2019
Resolved
The port main engine exhaust pipe is damaged from the rudder arm, make repairs as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 June 2019
Resolved
The stbd fuel shutoff valve handle is deteriorated, replace the handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2019
Resolved
Due to the removal of equipment there are numerous dead end wires in the lifejacket locker, water tank void, and under the main deck operating station; remove all unused wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 June 2019
Resolved
The vessel does not have rudder stops as required, install rudder stops.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 7 June 2019
Resolved
The sewage discharge valve handle is deteriorated, replace the handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 June 2019
Resolved
The guides for the freeing port covers are not structurally sound, make repairs as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2019
Resolved
Several wire runs coming off the bus bar under the main deck operating station do not have overcurrent protection, install overcurrent protection were needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 June 2018
Resolved
The publication on board is outdated, provide the vessel with a new Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 June 2018
Resolved
Provide the vessel with the Coast Guard Light List.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 June 2018
Resolved
Provide the vessel with Tide Tables and Tidal Current Tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 June 2018
Resolved
The stern light is not operational, repair as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Lifesaving › Lifefloat › Paddle
Issued 21 June 2018
Resolved
Provide one new paddle for the lifefloats due to deterioration, and insure all paddles are properly lashed to the floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 June 2018
Resolved
Renew the reflective material on the life jackets as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 June 2018
Resolved
Update the first aid kit to insure proper inventory and all items are within the expiration dates.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 June 2018
Resolved
The fire extinguisher at the operating station is beyond it's service date, have the extinguisher serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Engineering › Fuel Oil Service System › Hose
Issued 21 June 2018
Resolved
Install chaffing gear where neeeded on the fuel oil and lube oil hoses in the engine compartment as discussed during the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2018
Resolved
Properly terminate all dead end wires under the operating station console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 21 June 2018
Resolved
Install overcurrent devices as needed in the unprotected power sources under the operating station console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 June 2018
Resolved
Remove the wing nuts from the battery connections and install mechanical type fasteners.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Stability › Watertight Integrity › General
Issued 21 June 2018
Resolved
The hatch to the lazarettte does not seal properly; maintenance and adjust the hatch as needed to insure a watertight seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 March 2017
Resolved
Vessel has 19 servicable type I PFD's. Passenger count limited to 17 with 2 crew until 6 adult type I pfd's are replaced.
Due 24 April 2017
Resolved 5 April 2017
Resolution: Vsl obtained new wasted clips from the manufactured and had them properly installed on existing PFD's.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 March 2017
Resolved
Port and Starboard Nav lights are frosted over to a point visibility is limited. Replace lens or entire light on both sides.
Due 24 April 2017
Resolved 5 April 2017
Resolution: Both nav lights were replaced and operationally tested.
Personnel › Training › First Aid/CPR
Issued 24 March 2017
Resolved
Provide proof of full term first aid training. Temporary cards have expired.
Due 24 April 2017
Resolved 5 April 2017
Resolution: Another temporary first aid card was issued. Awaiting permenant card.
Communications › Radio Communications › EPIRB
Issued 24 March 2017
Resolved
Replace hydrostatic release on EPIRB prior to March 31, 2017 (expiration date).
Due 31 March 2017
Resolved 5 April 2017
Resolution: Hydrostatic release for EPIRB has been replaced.
Communications › Radio Communications › EPIRB
Issued 24 March 2017
Resolved
Provide documentation for EPIRB registration - commercial.
Due 24 April 2017
Resolved 5 April 2017
Resolution: Documentation for EPIRB registration was provided onboard.
Navigation › Piloting/Steering › Marine Charts
Issued 31 May 2016
Resolved
Provide the vessel with an updated navigation chart.
Due 14 June 2016
Resolved 7 June 2016
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 May 2016
Resolved
Repair the compass light as necessary.
Due 14 June 2016
Resolved 7 June 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 May 2016
Resolved
The water light on the port life float is working intermittently, repair or replace as necessary.
Due 14 June 2016
Resolved 7 June 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 May 2016
Resolved
Provide the ring buoy with a 60' life line due to incorrect length.
Due 14 June 2016
Resolved 7 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016
Resolved
Provide a splint for the first aid kit.
Due 14 June 2016
Resolved 7 June 2016
Stability › Watertight Integrity › General
Issued 31 May 2016
Resolved
Provide a pipe cap for the abandon through hull pipe in the engine compartment, stbd side.
Due 14 June 2016
Resolved 7 June 2016
Engineering › Bilge Water Management System › Pump
Issued 31 May 2016
Resolved
Replace the two non-approve electric bilge pumps with UL approved type.
Due 1 July 2016
Resolved 6 July 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2012
Resolved
Properly terminate wires under operating station in main cabin.
Condition: Improper Installation
Due 10 June 2012
Resolved 18 May 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2012
Resolved
Remove/replace unapproved wiring under operating station in main cabin
Condition: Improper Installation
Due 10 June 2012
Resolved 18 May 2012
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2012
Resolved
Provide current/corrected charts
Condition: Improper Installation
Due 10 June 2012
Resolved 18 May 2012
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 10 May 2012
Resolved
Provide a means to secure marine sanitation device within No Discharge Zone.
Condition: Improper Installation
Due 17 May 2012
Resolved 18 May 2012
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 10 May 2012
Resolved
Provide Emergency Broadcast Instructions
Due 17 May 2012
Resolved 18 May 2012
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 May 2012
Resolved
Ensure waterlight lanyard is properly rigged around body of float.
Condition: Improper Installation
Due 17 May 2012
Resolved 18 May 2012
Lifesaving › Hand Flares › Expired
Issued 26 March 2008
Resolved
Replace expired flares 3 red/3 orange.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2008
Resolved 14 April 2008
Resolution: Received fax from O/Op showing purchase of required flares
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 March 2008
Resolved
Radar not operating properly. Repair or remove from vessel.
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 14 April 2008
Resolution: Received fax from O/Op stating the radar had been repaired and is operating properly.
Lifesaving › Lifefloat › Pendant
Issued 26 March 2008
Resolved
Life float pendants missing/wasted. Replace all pendants.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2008
Resolved 14 April 2008
Resolution: Received fax from O/Op stating the life float pendants had been replaced.
Lifesaving › Lifefloat › Retroreflective Material
Issued 26 March 2008
Resolved
Lifefloat retroreflective tape wasted. Replace all retroreflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2008
Resolved 14 April 2008
Resolution: Received fax from O/Op stating the retro-reflective tape had been placed on the life float.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 March 2007
Resolved
Renew retroreflective material for identified type I PFD’s.
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 10 April 2007
Resolution: Renewed reflective tape on life jackets. Verified by marine inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 March 2007
Resolved
Repair thru hull valve for head, currently leaking around valve and hose connection.
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 10 April 2007
Resolution: Replaced hose for head and doubled clamp. No leakage detected. Verified by marine inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 March 2007
Resolved
Provide approved First Aid Kit or organize existing kits to meet required standards.
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 10 April 2007
Resolution: Renewed first aid kit. Verified by marine inspector.
Construction/Loadline › Structures › Scuttle
Issued 21 March 2007
Resolved
Provide new gaskets for hatches on main deck.
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 10 April 2007
Resolution: Renewed gaskets on rear deck hatches. Verified by marine inspector.
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 March 2007
Resolved
Provide new publication for operational area.
Due 15 April 2007
Resolved 21 March 2007
Resolution: Vsl rep provided publication.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 March 2007
Resolved
Provide 2007 tables for tides and currents.
Due 15 April 2007
Resolved 21 March 2007
Resolution: Vsl rep provided pulication.
Navigation › Piloting/Steering › Marine Charts
Issued 21 March 2007
Resolved
Provide COLREGs / Navigational Rules.
Due 15 April 2007
Resolved 21 March 2007
Resolution: Vsl rep provided nav rules publication.
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 January 2007
Resolved
Provide new fitting for hydraulic fuel line at steering ram. Existing hose wasted and failed.
Due 21 March 2007
Resolved 21 March 2007
Resolution: Renewed hydraulic lines for steering system. Verified by marine inspector..
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 January 2007
Resolved
Provide a positive shut off valve at hull for sink drain in forward cabin. Current hose has no valve and discharges at waterline.
Due 21 March 2007
Resolved 21 March 2007
Resolution: Provided valve for deck drain. Verified by marine inspector.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 January 2007
Resolved
Provide a positive shut off valve at hull for sink drain in forward cabin. Current hose has no valve and discharges at waterline.
Due 21 March 2007
Resolved 21 March 2007
Resolution: Installed valve on drain. Verified by marine inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 23 January 2007
Resolved
Provide a cap for through hull fitting not being used in bilge area of main cabin.
Due 21 March 2007
Resolved 21 March 2007
Resolution: Capped thru hull penetration. Verified by marine inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2006
Resolved
Required items in kit are expired, replace all expired items with new.
Due 15 April 2006
Resolved 14 April 2006
Resolution: Renewed first aid kit. Verified by marine inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 April 2006
Resolved
Provide tide tabels for vessel.
Due 15 April 2006
Resolved 14 April 2006
Resolution: Provided copy of tide tables.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 April 2006
Resolved
Provide copy of Coast Pilot for operational area.
Due 15 April 2006
Resolved 14 April 2006
Resolution: Provided copy of Coast Pilot (Reeds).
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 April 2006
Resolved
Unable tp proof operational testing of shut down of generator after activation of fixed fire system. Provide operational test of fixed fire fighting system. Vessel may not carry passengers and use generator at same time.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 14 April 2006
Resolution: Vessel completed satisfactory test of auto shut of generator upon fixed system activation in presence of marine inspector.
Lifesaving › Lifefloat › Paddle
Issued 3 April 2006
Resolved
Provide second paddle for life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2006
Resolution: Provided second paddle for life float. Veridied by marine inspector.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 April 2006
Resolved
Attach waterlight to lifefloat and renew waterlight line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2006
Resolution: Replaced batteries for waterliht and attached to life float. Vferified by marine inspector.
Lifesaving › Lifefloat › Painter
Issued 3 April 2006
Resolved
Attach sea painter to lifefloat and reroute bitter end of sea painter/weak link to not pass under coil housing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2006
Resolution: Attached sea painter to life float and rerouted bitter end. Verified by marine inspector.
Lifesaving › Lifefloat › Paddle
Issued 3 May 2005
Resolved
Provide 1 extra paddle for the vessel's life float.
Due 15 May 2005
Resolved 6 May 2005
Engineering › Bilge Water Management System › Pump
Issued 1 April 2004
Resolved
Prior to carriage of passengers, renew operation of bilge pump under main cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2004
Engineering › Bilge Water Management System
Issued 7 May 2003
Resolved
Prior to carrying passengers, repair aft most High Water Alarm. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2003
Lifesaving › Lifebuoys
Issued 7 May 2003
Resolved
Patch Life Ring buoy. LEGACY COMPONENT DESC: Body
Due 7 June 2003
Resolved 30 May 2003
Communications › Internal Communications System
Issued 18 April 2002
Resolved
Provide FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 19 May 2002
Resolved 27 June 2002
Navigation › Piloting/Steering
Issued 18 April 2002
Resolved
REPAIR STEAMING / ANCHOR LIGHT ASSEMBLY TO WORK SEPARATELY.
Action required: 705 - Other - as specified
Due 19 May 2002
Resolved 3 May 2002
Accommodation/Occupational Safety
Issued 18 April 2002
Resolved
Mark the upper deck for total persons allowed and provide proper rails prior to carrying passengers on the upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2002