MAURY USCG vessel records
← All vessels

SUNDANCER

SUNDANCER is a 1988 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 2016, most recently in April 2026, along with 118 deficiencies and 10 casualty investigations between 2009 and 2025.

Records from 2009 to 2026. Most recent: inspection, 24 April 2026.

Built
1988
Last inspected
24 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDD6656
311334
Flag
UNITED STATES
Maury page id
psix-311334

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded14
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)39.0 ft × 14.0 ft × 8.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builder#1 BOAT MFG INC · KEY WEST FLORIDA, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLITTLE RIVER, SC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAFARI IV Passenger (Inspected) · MISLE 213820 · 8 May 2024 · activity 7917243PRIDE OF THE CAROLINAS Passenger (Inspected) · MISLE 46582 · 26 July 2023 · activity 7757631SAFARI IV Passenger (Inspected) · MISLE 213820 · 26 July 2023 · activity 7757631

Inspection history · 46

24 April 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8358175
23 January 2026 Internal Structural Exam · Vessel Attendance · Examination of Repairs · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8300478
11 April 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8111585
5 April 2025 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8105708
5 April 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8112157
9 September 2024 Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7999511
8 September 2024 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7998872
11 May 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7910495
11 May 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7911267
8 May 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7908864
8 May 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7917243
18 February 2024 Deficiency Check · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7867027
18 February 2024 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7868629
10 January 2024 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7848068
1 November 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7818859
30 October 2023 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7816217
27 July 2023 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7753480
26 July 2023 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7757631
28 March 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7664100
22 March 2022 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7416753
23 February 2022 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 7401780
31 January 2022 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7383536
1 December 2021 Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7360004
28 June 2021 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7238669
13 May 2021 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7193381
14 September 2020 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7058641
4 September 2020 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7053371
21 May 2020 DAPI Audit · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6957794
18 December 2019 Drydock Exam · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6871834
22 August 2019 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6819724
21 August 2019 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6795956
6 May 2019 Deficiency Check · Examination of Repairs · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6673729
16 April 2019 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 6664039
15 April 2019 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6668460
27 February 2019 Type not recorded
No type recorded · USCGC NATHAN BRUCKENTHAL (WPC-1128) · USCG East District (CGD-E) · Activity 6636543
1 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6397441
8 December 2017 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6319787
22 August 2017 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6248283
21 August 2017 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6248101
2 May 2017 Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6137217
23 March 2017 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6113550
23 February 2017 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6089113
23 January 2017 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 6077088
2 December 2016 Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6051623
23 May 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5884343
22 January 2016 Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 5805006

Deficiency record · 118

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel experienced loss of propulsion. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2025
Resolved 7 April 2025
Resolution: Inspectors cleared deficiency at 1404.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel experienced a battery casualty and unable to operate, which resulted the vessel being towed to the dock. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2024
Resolved 9 September 2024
Resolution: New starting batteries were installed and vessel operational test conducted for approximately 30 minutes. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2024 Resolved
Propulsion machinery must be suitable in type and design for the hull in which it is installed and capable of operating at constant marine load without exceeding designed limitations. On 11MAY24 the vessel required towing to the dock due to an inability to restart the main engine caused by an electrical issue, with passengers still on board. Identify and correct electrical issue to the satisfaction of the Coast Guard prior to carrying passengers. 46 CFR 182.200(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2024
Resolved 13 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel had waterpump failure on Main engine resulting in vessel being towed to the dock w/ passengers on board.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2024
Resolved 20 February 2024
Resolution: Raw water pump was replaced and tested sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2023 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. The bolt that holds the steering ram in place sheared off causing the steering ram to come loose and not able to steer the vessel. Make proper repairs to the steering ram prior to getting underway.
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 1 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 7 August 2023 Resolved
Windows at the operating station must be sufficient in size, properly located, and provide an adequate view for the safe navigation in all operating conditions; the port centerline window in the operating station is hazed over, restricting visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2023
Resolution: Received objective evidence glass was renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel's main engine is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2023
Resolution: Main engine replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2022 Resolved
Vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Forward bilge pump float switch failed to energize the electric submersible bilge pump (local operation).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 28 February 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2022 Resolved
Vessel required to be equipped with fixed fire extinguishing system in the machinery space. Existing pre-engineered fire extinguishing system failed to operate as designed (audible alarm failed to sound when tested).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 25 March 2022
Resolution: Controle module was replaced and syatem tested sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 January 2022 Resolved
Vessel required to be equipped with SSB/HF radio-telephone or satellite phone w/FCC waiver. Satellite phone installation failed to send/receive calls during testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 28 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 January 2022 Resolved
Vessel required to carry current/up to date marine charts for areas transited. Existing marine chart #11534 was expired/out of date.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 28 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2022 Resolved
Vessel required to be equipped with life saving equipment (life floats). Existing life float installation requires a new painter line required due to UV deterioration, renewal of markings (name of vessel, quantity/capacity, and retro-reflective markings required renewal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 28 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 January 2022 Resolved
Vessel required to be equipped with navigational lights prescribed by regulation. Starboard navigational side light required repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 3 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2022 Resolved
Vessel required to be equipped with PFD's for each person on board. Five adult Type I PFD's were removed from service along with one child Type I PFD due to unserviceability/age.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 3 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2022 Resolved
Vessel required to be equipped with a ring life buoy. Existing ring life buoy required replacement due to unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 28 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2022 Resolved
Vessel required to be equipped with portable fire extinguishers precribed by regulation. Portable 10-B:C extinguisher located at the operators station requires mounting in an approved bracket (currently stowed under operators seat).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 3 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 January 2022 Resolved
Vessels watertight hatch(s) are required to be marked. Existing watertight hatch(s) are not properly marked/missing markings "WATERTIGHT HATCH KEEP CLOSED".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 3 March 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 January 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 2 April 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2022 Resolved
Vessel required to be equipped with peripheral deck railings. Missing rail courses/safety chains IWO port & starboard embarkation stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 28 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2022 Resolved
Vessel required to be equipped with a suitable first aid kit for service intended. Existing first aid kit was insufficient for service intended.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 December 2021 Resolved
Fill in the holes in the main deck where bench seating has been removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 January 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 August 2021 Resolved
Vessel required to be equipped with bilge high water alarms. Existing bilge high water alarm was inoperable/disconnected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 August 2021 Resolved
Vessel required to be equipped with bilge pumps. Existing electric submersible bilge pump IWO lazarette was inoperable/disconnected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 August 2021 Resolved
Vessel required to be equipped with a fire extinguishing system to protect the machinery space(s). Existing pre-engineered fire extinguishing system failed to allow the engine to refire in override mode.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2021 Resolved
Vessel required to be equipped with emergency fuel shut-off valves. Existing fuel shut-off valve failed to fully close when activated by the manual pull station at the operators station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2021 Resolved
Vessel required to be equipped with a suitable steering system. Existing rudder post packing gland requires maintenance/repair due to water ingress.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2021
Resolved 14 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2021 Resolved
Vessel required to be equipped with a pre-engineered fire extinguishing system. Existing pre-engineered fire extinguishing system is not receiving the required power when the key switch is activated (not installed as per manufactuers instructions).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2021
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2021 Resolved
Vessels propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Existing propulsion shaft requires "drawing" for further inspection. To be completed at next scheduled drydock on/about 31DEC2021.
Action required: 705 - Other - as specified
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2021 Resolved
Vessels propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Existing strut assembly (aft) requires permanent repair due to a fracture. To be completed at next scheduled drydock on/about 31DEC2021.
Action required: 705 - Other - as specified
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2021 Resolved
Vessels propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Existing propulsion shaft is "misaligned" resulting in "uneven" wear of the water lubricated bearings. To be completed at next scheduled drydock on/about 31DEC2021.
Action required: 705 - Other - as specified
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2021 Resolved
Vessels propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Existing water lubricated bearings are showing signs of "uneven" wear. Bearings require further inspection and/or replacement. To be completed at next scheduled drydock on/about 31DEC2021.
Action required: 705 - Other - as specified
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2021 Resolved
The machinery and equipment installed on each vessel must be suitable for the vessel, it's operation, and for the purpose intended; the main engine is experiencing electrical issues which are preventing the proper operation of the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2021
Resolution: Attending Inspector witnessed satisfactory sea trials.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2021 Resolved
Vessel required to carry current/up to date marine charts for areas transited. Existing charts were outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 1 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2021 Resolved
Vessel required to be fitted with operable navigational lights. Vessels stern light was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 27 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 May 2021 Resolved
Windows and other openings at the operating station must provide an adequate view for safe navigation in all operating conditions. Existing windows were restricting the operator's visibility due to clouding/hazing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 1 December 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021 Resolved
Vessel exhaust system shall not allow exhaust gases to leak from the piping or any connections. Existing exhaust piping system has exhaust leak(s).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2021 Resolved
Flexible hose used in electric submersible bilge pump installations shall be suitable for intended use. Existing flexible hose exceeds the manufacturers recommendations as far as length. The existing hose is routed from the transom area all the way to the fwd part of the machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 1 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2021 Resolved
Vessel shall be equipped with navigational lights as prescribed by USCG Navigational Rules. Vessel has two sets of navigational side lights installed & all around white light is not positioned correctly on the vessels mast. Vessel is not compliant with applicable navigational rules .
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2020 Resolved
An annual inspection is required to ensure vessel is fit for continued service intended. Attending Inspector identified (minor) water intrusion IWO port transom where hydraulic trim tab actuator mounts to hull. Actuator to be removed from vessel and area ground for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 14 September 2020
Resolution: Attending Inspector verified repairs/corrections made to port hydraulic trim tab actuator.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 May 2020 Resolved
Vessel required to carry on board a valid FCC Safety Radio-telephony Certificate. Vessels existing FCC Safety-Radio-telephony Certificate was missing/expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 29 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2020 Resolved
Life floats are required to be marked with vessels name. Existing markings are faded/worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2020
Resolved 14 September 2020
Resolution: Attending Inspector verified renewal of markings for life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2020 Resolved
An annual inspection is required to ensure lifesaving equipment is in a serviceable condition. Life float netting was found deteriorated/torn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2020
Resolved 14 September 2020
Resolution: Attending Inspector verified renewal of netting IWO life float.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2020 Resolved
Vessel required to be fitted with operable ventilation closure devices when fitted with pre-engineered fire extinguishing system. Existing ventilation closure devices required adjustment to ensure proper sealing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2020
Resolved 14 September 2020
Resolution: Attending Inspector verified adjustments/repair to ventilation closure devices.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. The bottom of the vessels keel showed signs of fracture/delamination/soft spots. Attending Inspector required grinding of keel for further inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 30 December 2019
Resolution: Vessels keel was ground for further inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Vessels keel showed signs of "checking". Attending Inspector required grinding of keel for further inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 30 December 2019
Resolution: Vessels keel was ground for further inspection. The "checking" was a result of voids between the laminates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2019 Resolved
periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Vessels propellor flukes were damaged on the trailing edge(s).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 30 December 2019
Resolution: Vessels propellor was serviced/re-installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Excessive play was noted in rudder post/tiller arm/keyway.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2020
Resolved 30 December 2019
Resolution: Vessels tiller arm was re-installed/adjusted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Excessive wear noted IWO aft strut water lubricated bearing & shaft. *May be result of misalignment of strut/bearing hub.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2020
Resolved 30 December 2019
Resolution: Aft strut bearing was renewed and strut assembly re-installed/adjusted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Sea valve for main diesel engine raw water system was missing it's handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 21 May 2020
Resolution: Attending Inspector(s) verified installation of handle for raw water sea valve.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Vessels keel bolts required adjustment/tightening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 30 December 2019
Resolution: Keel bolts were adjusted/tightened.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Delamination of (port/stbd) POTW tanks noted IWO machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2020
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified repairs IWO port/starboard POTW tanks.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 December 2019 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudder, through hull fittings, sea valves and strainers and shall be of sufficient scope to determine that these items are in satisfactory condition for service intended. Open communication (holes) noted IWO forward bulkhead IWO machinery space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 21 May 2020
Resolution: Attending Inspector verified sealing of bulkhead penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2019 Resolved
Vessel experienced a catastrophic failure of the transmission/reduction gear assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2019
Resolution: Vessels transmission/reduction gear assembly was replaced "in kind".
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 May 2019 Resolved
Vessels name/hailing port is obstructed by diving platform mounted to transom.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) noted that the O/O elected to remove dive platform from the transom of the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2019 Resolved
Vessel failed to carry current/up to date marine charts for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 18 December 2019
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 May 2019 Resolved
Vessel failed to carry current/up to date navigational publications for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified the carriage of current/up to date navigational publications for areas transited.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2019 Resolved
Renew emergency escape markings IWO fwd void/escape hatch/head.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified emergency escape markings.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 6 May 2019 Resolved
Provide operating instructions for Type III MSD system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified posting of operating instructions for installed toilet.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 May 2019 Resolved
Provide visual indicator for bilge high water alarm @ console.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) performed satisfactory operational test of the vessels bilge high water alarm.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2019 Resolved
Pre-engineered fire extinguishing system (FIREBOY) failed to allow the main engines to re-start in the override position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified operation of pre-engineered (Fire Boy) extinguishing system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2019 Resolved
Provide supports for electrical wiring/conductors IWO machinery space overhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of securing devices for electrical conductors IWO engine room overhead.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2019 Resolved
Repair main deck vertical supports IWO machinery space (to transom).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified repairs made to main deck vertical stiffeners (engine room/lazarette).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2019 Resolved
Rot noted IWO main deck @ fwd watertight hatch (centerline). Owner/Operator to submit repair proposal prior to commencing repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified repairs made IWO vessels main deck/watertight hatch assembly.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 May 2019 Resolved
Remote fuel shut-off valve does not fully close when activated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 18 December 2019
Resolution: Attending Inspector(s) verified adjustments to emergency fuel shut-off valve and witnessed satisfactory operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2019 Resolved
Peripheral deck railings missing hardware (aft main deck).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of hardware IWO main deck railings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2019 Resolved
PFD donning instructions were not posted on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified posting of PFD donning instructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2019 Resolved
Renew emergency fuel shut-off markings/instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified markings for emergency fuel shut-off valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2019 Resolved
Fuel fill pipes were not properly bonded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified installation of bonding straps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2019 Resolved
Renew fuel fill flexible hose assemblies where required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 20 April 2020
Resolution: Attending Inspector(s) verified renewal of fuel fill flexible hose connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2019 Resolved
Electric submersible bilge pumps were not properly secured to prevent movement/floating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of electric submersible bilge pumps.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 May 2019 Resolved
Provide current/ up to date FCC Safety Radio-telephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 29 June 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 May 2019 Resolved
Satellite phone failed to establish a connection during the inpsection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 18 December 2019
Resolution: Attending Inspector(s) verified operation of satellite phone installation.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 May 2018 Resolved
22-person life float required repair/replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified repairs made to 22-person life float.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 May 2018 Resolved
FCC Radio-Safety Telephony Certificate for VHF-FM radiotelephone expired.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 20 April 2020
Resolution: Duplicate deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2018 Resolved
PFD water lights were inoperable at time of inpsection (dead batteries).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified operation of PFD water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2018 Resolved
Floating water light for ring buoy was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified operation of floating water light for ring buoy
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 May 2018 Resolved
Vessels navigational publications were out of date for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigatonal publications for areas transited.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2018 Resolved
Expired items were noted in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified renewal of expired items in first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2018 Resolved
PFD stowage markings were improper (type/qty).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified renewal of PFD stowage markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2018 Resolved
Bilge pump float switch IWO fwd bilge inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified operation of fwd submersible bilge pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2018 Resolved
Port navigational side light was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified operation of navigational lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 May 2018 Resolved
Fwd watertight hatch was not properly tethered.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation of tethering devices IWO main deck hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2018 Resolved
Fuel oil vent hoses were deteriorated/required replacement (between tank and main deck).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation/replacement of fuel oil vent hoses between tanks and vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2018 Resolved
Fractured exhaust hangers IWO main diesel engine exhaust system (machinery space/lazarette).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified condition of all exhaust hangers.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 May 2018 Resolved
Ventilation closure device hardware required replacement due to severe corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified replacement of ventilation closure hardware & performed operational tests of each closure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2018 Resolved
Flexible hose connections IWO main diesel engine required adjustment/tightening due to water leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified condition of flexible hose connections IWO main diesel engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 May 2018 Resolved
Main deck watertight hatches missing required markings (WATERTIGHT HATCH KEEP CLOSED).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified presence of main deck hatch markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2018 Resolved
Exposed piping IWO main diesel engine turbo-charger piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation of heat wrap IWO main diesel engine turbo charger.
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2017 Resolved
Repair nicks in anti-foulant/gel coat IWO hull structure (FRP) where marked.
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified repairs made IWO vessels hull/gel-coat.
Engineering › Steering Gear System › Rudder Stock
Issued 8 December 2017 Resolved
Ajust/repair excessive play IWO rudder post/tiller arm assembly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified repairs/adjustments made IWO rudder post/tiller arm assembly.
Construction/Loadline › Hull › Side Shell
Issued 8 December 2017 Resolved
Delamination noted IWO port & starboard fresh water tanks (machinery space).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified repairs made IWO port & starboard fresh water tanks IWO machinery space.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 December 2017 Resolved
Repair/replace bracket/guide for remote fuel shut off reach rod assembly IWO machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified repairs made IWO emergency fuel shut off reach rod assembly.
Engineering › Sea-water System (primary cooling) › Valve
Issued 8 December 2017 Resolved
Repair/replace gate valve IWO main diesel engine raw water cooling intake. Existing gate assembly is gouged/damaged.
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified replacement of gate valve IWO main diesel engine raw water intake/sea chest.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 December 2017 Resolved
Adjust/tighten clamps IWO main diesel engine exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified adjustments made IWO main diesel engine exhaust piping.
Engineering › Bilge Water Management System › Hose
Issued 8 December 2017 Resolved
Install proper type/size clamp IWO electric submersible bilge pump discharge hose (fwd compartment).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified installation of proper type/qty of clamps IWO electric submsersible bilge pump IWO fwd compartment.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 December 2017 Resolved
Seal all watertight bulkhead penetrations IWO fwd machinery space bulkhead.
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 1 May 2018
Resolution: Attending Inspector(s) verified repairs made IWO fwd machinery space bulkhead.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 August 2017 Resolved
Repair/replace/operationally test VHF-FM radio following lightning strike.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2017
Resolution: Attending Inspector witnesssed installation of new VHF-FM marine radio and performed operational test.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 21 August 2017 Resolved
Repair/replace/operationally test single side band radio or provide an INMARSAT satellite phone or reduce vessels route on COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2017
Resolution: Attending Inspector verified the installation of satellite phone (station) and performed operational test.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 21 August 2017 Resolved
Repair/replace/operationally test Xintex/Fireboy control module for main diesel engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2017
Resolution: Attending Inspector witnessed installation of new Xintex Fireboy control module and performed operational test.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 21 August 2017 Resolved
Repair/replace/operationally test main diesel engine control panel @ helm (Cummins module)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2017
Resolution: Attending Inspector witnessed installation of engine control panel @ operating station and performed operational test.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 2 May 2017 Resolved
Pre-engineered fire suppression system inadvertently discharged its contents into machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2017
Resolution: Attending Inspector witnessed cylinder installation and performed operational test of the alarms/shutdowns.
Lifesaving › Inflatable Liferafts › Servicing
Issued 23 February 2017 Resolved
Inflatable raft was outside of its servicing dates *EXP DEC 2016
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the servicing of vessels life raft.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2017 Resolved
Replace twelve adult Type I PFD's due to unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the replacement of twelve (12) Type I adult PFD's.
Fire Fighting › Fire Bucket › Stenciling
Issued 23 February 2017 Resolved
Fire buckets were not stenciled/marked properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified markings of fire buckets.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2017 Resolved
Starboard navigation light lens was frosted and the fixture had been modified/altered.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector witnessed the installation of new navigation side lights. Performed operational test, test sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2017 Resolved
Vessels Commercial Fishing lights fixtures (red/white) were fitted with household bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the installation of marine bulbs as per the manufacturers instructions.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017 Resolved
VHF-FM radio was not programmed with vessels MMSI number (DSC equipped).
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified the programming of MMSI number in DSC VHF-FM radio.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 February 2017 Resolved
Vessel did not carry a current Certificate of Documentation (COD)
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of Certificate of Documentation.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 February 2017 Resolved
Vessel did not carry current/up to date navigation publications (USCG Light List, Tidal Current Tables, Navigation Rules)
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications.
Engineering › Bilge Water Management System › Valve
Issued 23 February 2017 Resolved
Vessels port fwd bilge discharge valve @ side shell was frozen/seized. In addition, hose clamps were not properly installed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector witnessed operation of fwd bilge discharge valve, test sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 February 2017 Resolved
Vessels emergency fuel shut off valve was corroded/partially frozen.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified operation of emergency fuel shut off valve assembly, test sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 February 2017 Resolved
Vesssel not provided with proper markings for emergency fuel shut off valve (missing operating instructions)
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Vessels crew made temporary markings for emergency fuel shut-off valves. Decals are being fabricated for permanent installation.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 February 2017 Resolved
Ensure deck hatches are operable and provide watertight seal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Attending Inspectors verified repairs made to main deck watertight hatches. Performed operational test, test sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 23 February 2017 Resolved
Vessels oil pressure gauge at console was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspector witnessed installation & operation of new oil pressure gauge.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 23 February 2017 Resolved
Isolate/repair oil leak @ main diesel engine turbo
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 23 March 2017
Resolution: Owner/Operator hired third party mechanic to isolate/repair oil leak on MDE turbocharger. Performed operational test, test sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 February 2017 Resolved
PFD stowage locations were not properly marked with qty of each size (adult/child)
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Attending Inspectors verified PFD stowage markings.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 23 May 2016 Resolved
Retroreflective material needs to be replaced on lifejackets to meet required condition and suffient surface area.
Condition: Damaged By Earlier Event
Due 23 May 2016
Resolved 30 May 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 May 2016 Resolved
Mast lights were not of sufficient type of bulb to meet standards
Condition: Invalid
Due 23 June 2016
Resolved 30 June 2016

Casualty record · 10

1 April 2009Routine · role: Involved in a Marine Casualty · activity 3445774
10 August 2012Routine · role: Involved in a Marine Casualty · activity 4419748
22 August 2017Routine · role: Involved in a Marine Casualty · activity 6248283
15 April 2019Routine · role: Involved in a Marine Casualty · activity 6668460
22 August 2019Routine · role: Involved in a Marine Casualty · activity 6819724
4 September 2020Routine · role: Involved in a Marine Casualty · activity 7053371
26 July 2023Routine · role: Involved in a Marine Casualty · activity 7757631
18 February 2024Routine · role: Involved in a Marine Casualty · activity 7868629
11 May 2024Routine · role: Involved in a Marine Casualty · activity 7911267
5 April 2025Routine · role: Involved in a Marine Casualty · activity 8112157
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.