07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 December 2025
Resolved
Fire hoses must be of commercial grade and conform to
UL 19 standards. The two existing fire hoses are not an approved type of hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2026
Resolution: New fire hoses provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 November 2023
Resolved
The construction and arrangements of the vessel must allow for the safe operations of the vessel in accordance with the terms of its COI giving consideration for the safety of the crew and passengers; the aluminum structures of the main deck canopy are deteriorated making repairs necessary to restore the structural integrity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2024
Resolved 23 May 2024
Resolution: Parts of the canopy were rewelded and plans made for a brand new canopy at the end of the season.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 May 2023
Resolved
Life float outer covering unserviceable condition. The outer covering was delaminated/wasted to the fiberglass core. Passenger count is reduced 45 passengers and 3 crew until the life float is renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2023
Resolved 8 May 2024
Resolution: 2 new 22-Person Liife Floats installed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 May 2023
Resolved
Life floats are missing the weak link certification tags.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 26 May 2023
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 30 August 2022
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz.
Vessel is restricted to a route not more than 20 nautical miles until the appropriate equipment is installed and in working order.
Action required: 705 - Other - as specified
Due 2 March 2023
Resolved 8 May 2024
Resolution: Satellite phone installed on the vessel in lieu of a SSB and MF installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2021
Resolved
Fire hazards on board shall be minimized. Attending Inspector(s) observed a diesel fuel leak from a fitting in way of port main diesel engine located in the fwd/inboard valley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2021
Resolved
Vessels main engines shall be cooled by water. Existing t-fitting for cooling water riser was leaking as a result of pinholes/wastage of the fitting in way of port main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2021
Resolved 13 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2021
Resolved
Vessels main diesel engines are required to be cooled with water. Existing exhaust riser in way of starboard main diesel engine (inboard) is wasted/holed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2021
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2021
Resolved
Vessels main diesel engines are required to be cooled with water. Existing fiberglass muffler assembly for starboard main diesel engine in way of lazarette (outboard) was found fractured/discharging water into the space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2021
Resolved 25 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 July 2021
Resolved
Vessel is required to be equipped with a power driven fire pump capable of achieving 60 psi (@pump discharge) at a rate of 50 gpm. Existing fire pump is not achieving required pressure/flow rate.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2021
Resolved 17 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2021
Resolved
Vessel is required to be equipped with a total of seventy-seven (77) adult Type I PFD's. Vessel currently carries a total of seventy-four (74) adult Type I PFD's.
*Vessels passenger capacity has been reduced to a total of seventy-four (74) total persons on board until the required quantity of adult Type I PFD's are carried.
Action required: 705 - Other - as specified
Resolved 15 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2021
Resolved
Vessel required to be equipped with a suitable steering system. The pump capacity is reduced at lower RPM's (<800 RPM) thus reducing the maneuverability of the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2021
Resolved 17 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 July 2021
Resolved
Vessel required to be fitted with navigational side lights. Existing side light (port) was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2021
Resolved 3 July 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2021
Resolved
n inspection for renewal of the COI shall include an examination of the vessels interior structure to ensure vessels remains fit for service intended. Existing floor framing in way of engine room (port/centerline/fwd) was found fractured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2021
Resolved 13 May 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 June 2021
Resolved
Vessel required to be equipped with an operable Class A AIS unit. Existing AIS unit is not transmitting vessel information.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 15 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 June 2021
Resolved
Vessel required to be equipped with current/up to date marine charts for areas transited. Existing marine charts are outdated/expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 28 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2021
Resolved
Vessel required to be equipped with portable fire extinguishers. Vessel missing one 10A 40-B:C portable extinguisher in way of the pilothouse/operators station and missing two 4A 60-B:C portable extinguishers IWO main accomodations space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 28 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 June 2021
Resolved
Vessel required to be equipped with life floats. Existing life float's weighted ring was found fractured/separated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 14 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2021
Resolved
Vessels escape routes from the accomodations space are required to be marked/identified. Existing escape routes are not properly marked (EMERGENCY EXIT KEEP CLEAR).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 14 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2021
Resolved
Vessels watertight hatches/doors are required to be marked. Existing watertight hatches are not marked properly (WATERTIGHT HATCH KEEP CLOSED).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 25 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2021
Resolved
Vessels electrical conductors are required to be secured with metal supports spaced not more than 24". Existing wiring/conductors are not properly supported throughout the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 28 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2021
Resolved
Fire hazards shall be minimized at all times. Vessels machinery space requires to be de-greased/cleaned to minimize fire hazard(s).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 15 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Flexible non-metallic hoses permitted for use in piping systems shall meet SAE J-1942 and be fitted with factory assembled end fittings. Existing flexible hoses IWO hydraulic steering system @ tank was deteriorated (outer jacketing).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 1 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Flexible hose may be used in fluid power systems. Existing flexible hose assembly (inboard) for steering system IWO lazarette was found leaking at hard pipe connection (lack of sealant).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 1 April 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 October 2020
Resolved
Fire hazards and other hazardous situations must be corrected at each inspection for certification and at every other vessel inspection. Excessive (hydraulic) oil was noted IWO lazarette bilge (due to steering system leak). Bilges to be pumped into approved containers and cleaned to minimize risk of fire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2020
Resolved 2 October 2020
Resolution: Vessels crew pumped oil from bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Fuel lines shall be accessible, protected from mechanical injury and effecitvely secured against excessive movement and vibration by use of soft non-ferrous metal straps with no sharp edges. Fuel supply piping for ships service generator was found damaged/leaking fuel into machinery space bilges.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2020
Resolved 1 April 2021
Resolution: Fuel lines have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Fuel tanks shall be adequately supported and braced to prevent movement. Tank mountings are missing spacers (x2).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 1 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 October 2020
Resolved
The level of a fuel tank must be equipped with a means to accurately determine the amount of fuel in each tank. Existing fuel level indicator/sending unit is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 4 June 2021
Resolution: Visual level indicator removed/sounding tube installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Vessels fuel supply system shall be equipped with a suitable marine type strainer in the engine compartment. Existing fuel strainer (Perko) IWO starboard MDE (inboard) is actively leaking when engines are in operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2020
Resolved 1 April 2021
Resolution: Perko fuel strainer was removed from service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 October 2020
Resolved
At each subsequent inspection all accessible parts of the vessels interior/exterior hull and watertight bulkheads shall be examined. Holing noted IWO fwd machinery space bulkhead, starboard side where bulkhead meets hull plating (approx. 2nd longitudinal side framing). Temporary repairs are authorized until permanent repairs can be effected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 4 June 2021
Resolution: Verified repairs made IWO watertight bulkhead separating fuel tank void & machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
All vessels shall be provided with suitable steering system. Existing supports for rudder IWO starboard side lazarette was found fractured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 4 June 2021
Resolution: Verified repairs made to rudder support brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2020
Resolved
Vessels independent fuel tank must be so installed to permit examination, testing or removal for cleaning with minimum disturbance to the hull structure. Existing fuel tank is not capable of being examined between tank and aft watertight bulkhead. Vessels condition is suspect for leaks.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Fuel tank was removed from its mountings for further inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 September 2020
Resolved
Whenever there is a potential hazardous condition on board the vessel, the owner, master or person in charge shall immediately notify the COTP. SSDG has significant oil leak resulting in machinery being coated in oil/oil mist and the saturation of exhaust high temperature wrap IWO exhaust manifold/piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Attending Inspector verified repairs made to SSDG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2020
Resolved
Whenever there is a potential hazardous condition on board the vessel, the owner, master or person in charge shall immediately notify the COTP. Port main engine has a significant oil leak IWO fwd crankshaft seal resulting in excessive oil/oil mist build up IWO fwd engine room/bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Attending Inspector verified repairs made to Port MDE.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2020
Resolved
Whenever there is a potential hazardous condition on board the vessel, the owner, master or person in charge shall immediately notify the COTP. Attending Inspector noted excessive oil/fuel in vessels bilges IWO engine room/tank room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Attending Inspector verified removal of fuel from vessels bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2020
Resolved
All engines must be water cooled. Starboard main engine is experiencing an issue with overheating. Attending Inspector observed coooling water/coolant stains from the expansion tank where the engine has been overheating and water has been pushing out of the expansion tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2020
Resolved 25 September 2020
Resolution: Attending Inspector verified repairs made to Starboard MDE.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020
Resolved
Vessel required to carry proper type/qty of portable fire extinguishers and be serviced annually. Vessels existing portable fire extinguishers were found expired (beyond annual servicing dates).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified servicing of portable fire extinguishers.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 June 2020
Resolved
Vessel required to carry and operable 406 MHz EPIRB. Vessels existing EPIRB antenna is damaged/requires servicing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified servicing/repair of EPIRB. Witnessed operational test.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 June 2020
Resolved
Vessel requires primary and secondary fixed fire pump(s). Existing fire pump(s) are not capable of achieving required pressure/gpm's.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2020
Resolution: Attending Inspector verified repairs made to port fire pump and witnesses satisfactory operational tests of primary and secondary fire pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2020
Resolved
Vessels steering system shall be adequate for size/service of vessel. Vessels existing steering system hydraulic ram assembly IWO lazarette is wasted/corroded (tie rods).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 4 June 2021
Resolution: Hydraulic ram assembly was replaced in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 June 2020
Resolved
Vessel is required to have name of vessel marked in way of port/starboard bow and transom. Vessels name is missing IWO port/starboard bow and name and hailing port missing from transom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2020
Resolution: Attending Inspector verified installation of vessels name IWO port/starboard bow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2020
Resolved
Vessels main diesel engines requires a raw water cooling system. The check valves IWO raw water cooling (intake) system were found leaking at inspection ports.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2020
Resolution: Attending Inspectors verified adjustments made to raw water check valves for main diesel engines.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 June 2020
Resolved
Vessel required to be fitted with navigational side lights. Existing side light IWO starboard pilothouse was found with improper base/light installed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified installation of the starboard navigational side light.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 June 2020
Resolved
Vessel required to be equipped with operable VHF-FM radio-telephone(s). Existing VHF-FM radio-telephones were inpoperable due to low voltage condition on board (Constavolt system).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified operation of VHF-FM radio-telephones.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 June 2020
Resolved
Vessels machinery space required adequate lighting. Existing lighting IWO machinery space (engine room) was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified operation of machinery space lighting.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2020
Resolved
Vessel required to post current/up to date FCC Safety Radio-telephony Certificate for VHF-FM radio-telephone installations. Existing FCC Safety Radio-telephony Certificate was found expired/faded/worn.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2020
Resolved 3 July 2020
Resolution: Attending Inspector verified renewal of FCC Safety Radio-telephony Certificate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2020
Resolved
Vessel required to carry alcohol testing devices (based on vessels route). Existing alcohol testing devices were found expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 28 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 June 2020
Resolved
Lighting fixtures required to be fitted with protective cover/globe(s). Lighting fixture IWO port/fwd head was missing protective cover/globe.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2020
Resolved 1 April 2021
Resolution: Verified installation of protective cover/globe for lighting fixture.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 June 2020
Resolved
Vessel required to be fitted with adequate lighting for working spaces. Lighting fixtures IWO main deck canopy were found loose/unsecured/hanging from conductors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 4 June 2021
Resolution: Verified installation of lighting fixtures IWO main canopy/main deck lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2020
Resolved
Vessels main diesel engines shall be equipped with proper type/size of exhaust piping. Exhaust leak noted IWO port main diesel engine @ exhaust manifold flange to exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified repairs made to port main diesel engine exhaust manifold/exhaust piping flange.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2020
Resolved
Vessels main diesel engines shall be equipped with gauges to monitor oil pressure. Port main diesel engine oil pressure gauge is inoperable (will not register pressure above 20 psi).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 4 June 2021
Resolution: Verified operation of oil pressure gauge for port main diesel engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2020
Resolved
Ring life buoys are required to be fitted with floating water light. Existing floating water light battery requires annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified renewal of batteries in lifesaving equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2020
Resolved
Vessels PFD stowage locations are required to be marked with type/size/qty. Existing markings does not reflect actual PFD stowage.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 29 June 2020
Resolution: Attending Inspector(s) verified PFD stowage location markings.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2019
Resolved
Bilge high water alarms were found "loose" IWO fuel tank void, engine room and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified adjustments/tightening of bilge high water alarm floats.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2019
Resolved
Bilge high water alarm (base) fractured IWO fuel tank void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified replacement of bilge high water alarm float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 July 2019
Resolved
Main deck hatch covers for machinery space were not equipped with securing device(s) (port/starboard).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of securing devices for main deck hatch covers for engine room/machinery space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2019
Resolved
Exterior pilothouse door gasketing required replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 1 April 2021
Resolution: Verified installation of peripheral door gasketing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2019
Resolved
Dogging handle IWO starboard pilothouse exterior door required repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 4 June 2021
Resolution: Verified installation of striker plate/performed operational test.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 July 2019
Resolved
Ship's sound producing device (ship's whistle) was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) witnessed operational test of ships whistle.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 July 2019
Resolved
Painter line for life floats required replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified renewal of painter lines for life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2019
Resolved
Rescue line for ring life buoy (aft) required replacement due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 9 March 2020
Resolution: Attending Inspector(s) verified installation of rescue line for aft ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2019
Resolved
Renew floating water light for ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 9 March 2020
Resolution: Attending Inspector(s) witnessed installation/operational test of aft floating water light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Renew flexible hose IWO starboard reduction gear/transmission due to outer jacketing deterioration/failure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of flexible hose IWO stbd MDE/reduction gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Provide "blocking" IWO main engine starting battery installation to prevent shifting/movement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of "blocking" IWO battery installations (machinery space).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2019
Resolved
Provide bracketing for fixed bilge piping (throughout the vessel).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of "brackets" IWO fixed bilge piping (throughout vessel).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2019
Resolved
Provide diagram/labeling for fixed bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 1 April 2021
Resolution: Verified posting of operating instructions for fixed bilge system.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 July 2019
Resolved
Remove (all) stainless fasteners/hardware from aft machinery space bulkhead and plug weld.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 1 April 2021
Resolution: Verified repairs made to watertight bulkhead between fuel machinery space/lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Grind/weld fractured exhaust support for SSDG IWO lazarette (port/overhead).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 2 October 2020
Resolution: Attending Inspector verified reparis to exhaust hanger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Provide bracketing for hydraulic steering piping IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of brackets IWO hydraulic steering piping (lazarette).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Repair hydraulic oil leak IWO hydraulic steering piping in fuel tank void (starboard/outboard).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 4 June 2021
Resolution: Verified repairs made to hydraulic steering piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2019
Resolved
Missing cover for electrical outlet IWO engine room/centerline/overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of cover for electrical outlet (machinery space overhead).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Provide/install bracket/stand off to support bilge piping IWO engine room (port side/inboard).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of "stand off" for fixed bilge piping (inboard port MDE).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2019
Resolved
Removed "dead ended" wiring IWO console/operators station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified removal of "dead ended" wiring IWO helm/console.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2019
Resolved
Remove "wing nuts" from emergency battery under console/operators station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified removal of "wing nuts" from emergency communications battery IWO console/helm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 July 2019
Resolved
Renew fixed bilge piping flexible couplings. Existing flex couplings are not suitable for service intended as per manufacturer.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 22 June 2020
Resolution: OCMI's (SEC NC/SEC CHAR) accepted flexible bilge piping couplings for fixed bilge system.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 16 July 2019
Resolved
Repair/replace compass light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified illumination of compass.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 16 July 2019
Resolved
Verify operation of MF/HF radio-telephone (SSB).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 22 June 2020
Resolution: Attending Inspector(s) verified operation (limited) of SSB radio-telephone.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 16 July 2019
Resolved
Verify operation of public address system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) witnessed satisfactory operational test of PA system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2019
Resolved
Provide proper markings indicating operation of emergency fuel shut-off valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified markings for emergency fuel shut-off valve.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2019
Resolved
Repair/secure passenger seating arrangements IWO main accomodations space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified repairs made to passenger seating.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 16 July 2019
Resolved
Provide operating instructions for installed toilets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 1 April 2021
Resolution: Verified posting of operatings instructions for installed toilets.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 July 2019
Resolved
Provide two portable emergency lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified carriage of two portable lights.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 July 2019
Resolved
Provide First Aid/CPR training for at least 50% of vessels crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified crew training (First aid/CPR).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2019
Resolved
Cap off/secure open hole @ main deck IVO lazarette watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified repairs made IWO lazarette watertight hatch/main deck.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 July 2019
Resolved
Provide markings for emergency exits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 9 March 2020
Resolution: Attending Inspector(s) verified emergency exit markings.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 July 2019
Resolved
Provide markings for watertight hatches/scuttles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified hatch/scuttle markings.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 July 2019
Resolved
Navigational side light screens require repainting due to UV deterioration/fading/chipping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified repainting of side light screens.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 July 2019
Resolved
Provide pressure gauge IWO fire pump discharge piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of pressure gauge for fire pump (primary).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019
Resolved
Provide Amperage meter for SSDG @ main switchboard in engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2019
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of Amperes gauge @ main switchboard (engine room).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2018
Resolved
Vessels ships service diesel generator is required to comply with the provisions of 46 CFR 183.310 & 46 CFR 183.320. Vessels ships service diesel generator experienced a mechanical failure that required the removal of the generator/prime mover. Vessels vital loads are not provided with two sources of power.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 13 May 2022
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 25 April 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 May 2018
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 April 2018
Resolved
Vessel did not carry carry means to conduct alcohol testing.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified carriage of alcohol testing devices.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2018
Resolved
Vessels navigation lights (NUC) were not fitted with proper marine style bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 30 May 2018
Resolution: Attending Inspector(s) verified installation of proper type/size of bulbs for fixtures.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2018
Resolved
Floating water light for 12-man life float was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 May 2018
Resolution: Attending Inspector(s) verified operation of floating water light for 12-person life float.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 April 2018
Resolved
Buoyant lifeline for port ring buoy required replacement due to deterioration (UV).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 May 2018
Resolution: Attending Inspector(s) verified renewal of lifeline for ring buoy.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2018
Resolved
Vessel did not carry/provide proof of enrollment in a maritime consortium.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified proof of enrollment letter.
Documentation › Markings/Placards › Warning Signs
Issued 25 April 2018
Resolved
Vessels emergency escapes were not properly marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 30 May 2018
Resolution: Attending Inspector(s) verified emergency escape markings.
Stability › Watertight Integrity › General
Issued 25 April 2018
Resolved
Watertight hatches for lazarette and machinery space required repair/adjustments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 2 July 2019
Resolution: Attending Inspector(s) verified repairs made IWO watertight hatches.
Engineering › Steering Gear System › Ram
Issued 25 April 2018
Resolved
Attending Inspectors noted a hydraulic oil leak IWO starboard hydraulic ram (inboard lazarette).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified repairs made to hydraulic steering system.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 April 2018
Resolved
Vessel did not carry current/up to date navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 30 May 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2018
Resolved
Vessels first aid kit container was broken/required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 June 2018
Resolution: Attending Inspector(s) verified replacement of first aid container.
Lifesaving › Lifefloat › Retroreflective Material
Issued 25 April 2018
Resolved
Retro-reflective tape IWO life floats required renewal (worn/UV deterioration).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 June 2018
Resolution: Attending Inspector(s) verified condition/renewal of retro-reflective markings for life floats.
Electrical › Electric Supply System (service) › Battery Charger
Issued 25 April 2018
Resolved
Battery charger IWO helm for emergency battery was not properly configured/wired.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 June 2018
Resolution: Attending Inspector(s) verified installation for battery charger IWO helm.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 April 2018
Resolved
Excessive ring terminals (power supply) for emergency battery IWO helm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 June 2018
Resolution: Attending Inspector(s) verified battery installation IWO helm (emergency battery)
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2018
Resolved
Dead ended wiring noted IWO port main diesel engine (outboard @ alternator).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified removal of dead ended wiring IWO port main diesel engine (outboard).
Engineering › Fuel Oil Service System › Filter
Issued 25 April 2018
Resolved
Broken fuel oil pressure gauges IWO port/starboard main diesel engine RACOR fuel filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 30 May 2018
Resolution: Attending Inspector(s) witnessed removal of fuel oil pressure guages IWO port/starboard main diesel engines.
Engineering › Lubricating Oil Service System › Hose
Issued 25 April 2018
Resolved
Lube oil cooler lines required replacement due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 November 2018
Resolution: Attending Inspector(s) verified installation of lube oil cooler flexible hoses.
Engineering › Fuel Oil Service System › Hose
Issued 25 April 2018
Resolved
Fuel oil hoses for main diesel engines does not meet SAE J-1942/SAE J-1475.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 9 March 2020
Resolution: Attending Inspector(s) verified fuel hose installation for both main diesel engines.
Engineering › Lubricating Oil Service System › Gauge
Issued 25 April 2018
Resolved
Lube oil pressure gauge @ console for port main diesel engine was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 3 May 2018
Resolution: Attending Inspector(s) verified installation of lube oil pressure gauge for port main diesel engine @ operators station.
Stability › Watertight Integrity › General
Issued 25 April 2018
Resolved
Main deck watertight hatches were not properly marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 30 May 2018
Resolution: Attending Inspector(s) verified markings for main deck watertight hatches.
Engineering › Steering Gear System › Ram
Issued 25 April 2018
Resolved
Isolate/repair excessive play in steering system (IWO tie bar connections @ ram).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 July 2019
Resolution: The steering system has been overhauled to include both rudder posts and rudders being renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 April 2018
Resolved
Remove all flexible hose connections IWO port & starboard main diesel engine exhaust piping for further inspection/repair (Moderate to heavy pitting noted). Replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 July 2019
Resolution: SEC NC Inspector(s) verified repairs made IWO main engine(s) exhaust piping.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 April 2018
Resolved
Renew flexible hose connections IWO port & starboard main diesel engine sea-chest valves due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 July 2019
Resolution: Flexible hose have been replaced.
Stability › Watertight Integrity › General
Issued 25 April 2018
Resolved
Renew gasketing material and provide securing devices for port & starboard engine hatch covers (non-watertight).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 3 October 2019
Resolution: Attending Inspector(s) verified installation of hatch securing devices.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 6 May 2017
Resolved
Starboard engine being replaced due to internal wear of cylinders.
Action required: 705 - Other - as specified
Resolved 11 May 2017
Resolution: Attending Inspector witnessed final installation of the starboard engine and performed operational testing (sea trials).
Navigation › Piloting/Steering › Marine Charts
Issued 26 January 2017
Resolved
Vessel did not have current/up to date naviational charts on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 January 2017
Resolved
Vessel did not have curent/up to date navigatonal publications on board (USCG Light List).
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of current/up to date navigation publications.
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 January 2017
Resolved
Vessel did not have current/up to date navigational publications on board (US Coast Pilot).
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of current/up to date navigation publications.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 26 January 2017
Resolved
Vessel did not have current/up to date navigational publications on board (Tide/Tidal Tables)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of current/up to date navigation publications.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 January 2017
Resolved
Vessel did not have EPA information posted in consicuous area on board.
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage/posting of company EAP (policy).
Lifesaving › Lifefloat › Serviceable
Issued 26 January 2017
Resolved
Vessels life floats required repair/painting to exterior coatings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified repairs made to life floats.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 January 2017
Resolved
Missing clip on starboard/fwd ring life buoy floating waterlight.
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified installation of corrosion resistant clip for floating water light.
Fire Fighting › Nozzles › Type
Issued 26 January 2017
Resolved
Vessels starboard aft fire station is not equipped with proper style/type of nozzle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verified carriage of proper type of fire nozzles.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 26 January 2017
Resolved
Vessels starboard fuel oil vent pipe (main deck) is not equipped with a flame screen.
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 23 March 2017
Resolution: Attending Inspector verfied installation of proper type/size of flame screen IWO starboard fuel oil vent.
Construction/Loadline › Hull › Side Shell
Issued 14 October 2016
Resolved
Port hull plating IWO forepeak required replacement due to heavy pitting (approx. 19" x 22").
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 31 October 2016
Resolution: Attending Inspector verified repairs made to vessels port hull plating IWO Forepeak (side shell).
Engineering › Bilge Water Management System › Hose
Issued 14 October 2016
Resolved
Bilge suction flexible hose IWO Forepeak was deteriored & required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified replacement of flexible hose connections IWO bilge system.
Construction/Loadline › Hull › Weld
Issued 14 October 2016
Resolved
Grind/re-weld fractured weldments IWO Forepeak
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 31 October 2016
Resolution: Attending Inspector verified repairs to fractured weldments.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 October 2016
Resolved
Junction box located IWO Forepeak (overhead) was wasted and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified replacement of junction box IWO Forepeak overhead.
Construction/Loadline › Hull › Side Shell
Issued 14 October 2016
Resolved
Crop/renew port side shell plating in order to removed two thr-hull fittings that are currently capped off and are no longer in use. *Owner/operators request. Size: 18" x 20" (approx.)
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 November 2016
Resolution: Attending Inspector verified replacement of existing thru-hull fitting plugs. Owner/Operator opted not to crop/renew plating.
Construction/Loadline › Hull › Weld
Issued 14 October 2016
Resolved
Grind/re-weld fractured weldments IWO deck/side shell framing IWO crews quarters (centerline/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 31 October 2016
Resolution: Attending Inspector verified repairs made to fractured weldments IWO crews quarters/bunk room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 October 2016
Resolved
Removed dead ended wiring IWO crews quarters, starboard side above top bunk.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified removal of dead ended wiring IWO crews quaters.
Construction/Loadline › Hull › Weld
Issued 14 October 2016
Resolved
Grind/re-weld aft bulkhead plating, upper corner where it meets the sideshell to ensure watertight integrity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 31 October 2016
Resolution: Attending Inspector verified repairs made to bulkhead.
Stability › Watertight Integrity › General
Issued 14 October 2016
Resolved
Seal all bulkhead penetrations to ensure watertight integrity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified repairs made to bulkhead sealings.
Engineering › Bilge Water Management System › Piping
Issued 14 October 2016
Resolved
Make bilge piping accessible for inspection IWO A/C Room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector witnessed installation of an access plate for monitoring bilge piping IWO A/C room.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 October 2016
Resolved
Junction box IWO A/C Room overhead was found wasted and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified replacement of junction box IWO A/C Room overhead.
Construction/Loadline › Hull › Side Shell
Issued 14 October 2016
Resolved
Crop/renew thru-hull fittings IWO port & starboard side shell for MSD System (approx. 18" x 22").
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 November 2016
Resolution: Attending Inspector verified repairs made to thru-hull fitting/piping IWO Port/Starboard MSD discharge valves. Performed NDT for weldments via dye penetrant testing.
Engineering › Bilge Water Management System › Piping
Issued 14 October 2016
Resolved
Re-congigure fire/bilge pump discharge valving IWO machinery space sideshell (starboard).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified repairs made to fire/bilge pump discharge piping. Performed NDT via dye penetrant testing.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 October 2016
Resolved
Provide insulation/protection for ships service generator exhaust piping IWO machinery space & lazarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified installation of heat wrap for generator exhaust piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 October 2016
Resolved
Provide insulation/protection for main disel engine exhaust piping IWO machinery space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified installation of heat wrap on main diesel engine exhaust piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 October 2016
Resolved
Renew clamps for port main diesel engine exhaust piping @ flexible hose connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified repairs to main diesel engine exhaust piping (clamps).
Construction/Loadline › Structures › Deck Plating
Issued 14 October 2016
Resolved
Isolate/repair pitting IWO main deck/lazarette overhead, port quarter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 November 2016
Resolution: Attending Inspector noted that the pitting/holing noted in the lazarette overhead were not accessible from the main deck. The affected area is located under the gunwale and is designed for draining water from main deck.
Engineering › Bilge Water Management System › Manifold
Issued 14 October 2016
Resolved
Provide markings IWO bilge manifold (identify spaces served).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 23 December 2016
Resolution: Attending Inspector verified that all bilge suction valves were properly marked with space served.
Engineering › Bilge Water Management System › Manifold
Issued 14 October 2016
Resolved
Perform operational test of vessels installed bilge pump/piping system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2016
Resolved 27 December 2016
Resolution: Attending Inspector performed operational test of vessels installed bilge suction from all spaces; Forepeak, Crews Quarters, A/C Room, Fuel Tank Space, Engine Room & Lazarette. Operational test was satisfactory.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 October 2016
Resolved
Crop/renew wasted areas of fwd machinery space bulkhead IWO port & starboard head installations.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified repairs to fwd machinery space bulkhead. Performed NDT via dye-penetrant testing.
Fire Fighting › Fire Hoses › Condition
Issued 8 March 2016
Resolved
Replace hose.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 6 April 2016
Communications › Audible Communications › Horn/Whistle
Issued 8 March 2016
Resolved
Replace horn.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 6 April 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 March 2016
Resolved
Replace first aid kit.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 6 April 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 March 2016
Resolved
Replace retro tape.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 6 April 2016