99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2025
Resolved
Vessel did not have an established drug and alcohol program.
46CFR185.212
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: Observed drug and alcohol program. All SAT
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 June 2025
Resolved
Vessel's fire system and portable extinguishers are due for inspection.
46CFR181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: Observed servicing certificate. All SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 June 2025
Resolved
Vessels' first aid kit, expired.
46CFR184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: Observed new first aid kit. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 June 2025
Resolved
EPIRB's HRU is expired.
46CFR180.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: Observed new HRU and proper installation. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025
Resolved
Ring buoy reflective tape is worn from the wheel house.
46CFR180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 June 2025
Resolution: Observed reflective tape on ring bouy. All SAT
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 June 2025
Resolved
STBD F/O remote COV was not functioning.
46CFR182.435
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: Observed repairs and proper function. All SAT
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 June 2025
Resolved
STBD Generator's F/O filter did not have a fire shield bowl.
46CFR182.435
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 June 2025
Resolution: Observed installation of new fire shield. All SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. MI found delaminated fiberglass near the port side sonar dome. Submit repair plan to local OCMI for approval, once approved complete repairs and notify local OCMI once repairs are complete.
Action required: 705 - Other - as specified
Resolved 1 December 2024
Resolution: Received photos from owner of repairs. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 March 2024
Resolved
The fire pump outlet must be fitted with a pressure gauge. Current gauge on pump is not operable. Must repair/replace to satisfaction of USCG Marine Inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2024
Resolved 27 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and protect crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Distribution panel covers need to be fully bolted and blanks need to be installed in areas without breaker switches in both the engine room and wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and protect crew, other persons, and the vessel from electrical hazards,
including fire, caused by or originating in electrical equipment, and electrical shock. Must provide good seal for main lighting conduit on fixture located on port side of engine space and properly dead end wires in wheel house under consul.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 March 2024
Resolved
Flex hoses used for vital systems must be double clamped on each end. Raw water cooling line in port generator was not double clamped.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 March 2024
Resolved
The shutoff valves at the fuel tank must be manually operable from outside the compartment in which the valve is located for all supply lines. Must install remote shut-offs for crossover lines in fuel tank or hard pipe the cross overs to the same material as the fuel tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 March 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by cover, guard, or rail. Need to install cover over rotating section of the bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 March 2024
Resolved
Each inlet/discharge pipe that penetrates the hull at least 6 inches above the waterline must have means to prevent water form entering the vessel if the pipe fractures. Valve handle was not connected to the raw water discharge valve for the generators. Must reinstall appropriate valve handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 11 March 2024
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Vessel operator did not have a radio operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 March 2024
Resolved
No marine employer shall engage or employ and individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. All crew members in a safety sensitive position shall be enrolled in a random drug testing program.
Vessel did not have proof of testing or enrollment for the crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 March 2024
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck and it must automatically actuate upon failure of the main lighting system. Emergency lighting not equipped with a single source of power must comply with 46 CFR 183.432 and be connected to an automatic battery charger. Vessel is restricted to daylight operations until adequate operation is performed to the satisfaction of a Marine Inspector.
Action required: 705 - Other - as specified
Resolved 27 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 August 2023
Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. No overnight passengers allowed until vessel meets 46 CFR 177.500.
Action required: 705 - Other - as specified
Resolved 25 June 2025
Resolution: Egress drills conducted. Alll SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 25 April 2023
Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. Your vessel must make the following corrections to meet the regulations:
1. Galley main salon area missing secondary means of Escape.
2. Passenger compartment missing secondary means of Escape.
Current secondary egress configuration utilizing a vertical ladder on a vessel of > 65’ is not in compliance with 46 CFR 177.500. Salon does not have secondary means of egress meeting requirements in 46 CFR 177.500
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 1 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 February 2023
Resolved
(c) Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450. Vessel failed to submit plans for system, missed installation date, and vessel is not currently in service due to fuel tank replacement.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: Witnessed satisfactory test of alarms during DDX.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 21 June 2022
Resolved
An EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. The EPIRB battery on board expired 04/2021. Vessel is restricted to voyages 3 NM or less until the battery is replaced.
Action required: 705 - Other - as specified
Resolved 24 June 2022
Resolution: Battery replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2022
Resolved
On a vessel of at least (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. The Aft bunk room bilge alarm was inoperable. Vessel must conduct hourly rounds which are logged in the vessels official log book until deficiency is rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 24 June 2022
Resolution: Replaced bilge alarm; tested satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 June 2022
Resolved
Every vessel must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 80.59 once every five years. If the vessel passes the inspection the technician will issue a communications Act Safety Radiotelephony Certificate. The Communications Act Radiotelephony Certificate expired as of April 2022. Cite: 47 CFR 80.903.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 24 June 2022
Resolution: Updated certificates provided to the attending MI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 June 2022
Resolved
Each EAP education program must include at least the following: display and distribution of a community service hot line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 24 June 2022
Resolution: Updated Drug & Alcohol policy/ EAP - now compliant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2022
Resolved
Materials used in piping systems must be acceptable to the cognizant OCMI. The refrigeration pipe in way of the starboard rudder post in the lazarette is being grinded away by the rudder machinery rubbing against it. Repair the damaged piping and adjust to provide sufficient distance from the rudder machinery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2022
Resolved 24 June 2022
Resolution: damaged piping replaced, no longer experiencing friction w/ steering components.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2022
Resolved
06 lifejackets had missing lights.
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: Corrected on the spot with new batteries/lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2022
Resolved
05 Lifejackets were missing whistles.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2022
Resolution: Corrected on the spot with new whistles.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Forward bulkhead Port Engine room electrical panel: Bottom exterior enclosure missing cable penetration cap.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Forward bulkhead Port Engine room electrical panel: Circuit breaker space opening; insert protective cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Forward bulkhead Wash down aux bilge panel: Loose cable connection from bottom; re-install.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Forward bulkhead Dead ended cable found at left side cable run of wash down aux bilge panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Port side Engine room water heater electrical power cable not properly installed / secured into water heater unit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 12 May 2021
Resolution: Verified that power cable was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Forward bulkhead near STBD bilge area; Electrical cable termination spliced in open air / wire nuts; provide proper splice techniques, and or terminate within an electrical junction box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Aft engine room near generators; overhead light fixtures 03 found missing bulbs, diffuser and not operational.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
STBD side outboard Main fuel tank Fuel oil supply valve handle corroded; Replace valve handle.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Forward engine room overhead electrical junction box cable connector missing.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Two conductor wires from STBD battery and going through Aft engine room bulkhead not properly protected. Provide wire protection and approved cable penetration going through bulkhead.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Portside outboard aft of engine overhead round electrical junction box cable missing connector. Re-install connector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Portside outboard aft of engine overhead round electrical junction box 2nd cable missing connector loose. Re tighten & re-install connector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Electrical extension cord found for kettle hot pot. Remove cord or provide approved permanent means to supply power to equipment
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Galley under sink: found dead ended cable; remove.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Electrical cable connector missing at junction box penetration. Install cable connector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 May 2021
Resolved
Aft wall 4 gang TV outlet missing outlet cover. Install cover.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 May 2021
Resolved
Aft wall 4 gang electrical outlet box power cable; no chaffing gear around cable penetration into outlet box. Provide chaffing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 3 May 2021
Resolved
Hydrofix EPRIB Hydrostatic release unit expired as of 04APR2021. Renew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2021
Resolved
Lazarette: Fixed firefighting pull box station missing 2 screws. Install missing screws.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2021
Resolved
Lazarrette: Fish hold tank water supply valve handle missing / corroded. Replace valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 11 May 2021
Resolution: Recieved Pictures of corrected deficiency.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 3 May 2021
Resolved
Vessel's single side band radio is inoperable. Repair or replace the single side band radio. Vessel is restricted to no more than 100 nautical miles from shore until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 12 May 2021
Resolution: Witnessed satisfactory test of SSB.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 May 2021
Resolved
Vessel's navigation charts were out of date. Provide up to date charts for the vessel's intended routes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 12 May 2021
Resolution: Vessel acquired new navigation charts.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 May 2021
Resolved
Fire pump gauge is inoperable. Repair or replace the fire pump gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 12 May 2021
Resolution: Witnessed satisfactory fire pump/gauge test.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 May 2021
Resolved
Only one crew member had an FCC Marine Radio Operator Permit. All licensed crew members that stand a navigation watch must hold an FCC Marine Radio Operator Permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 30 July 2021
Resolution: Vessel POC sent an email with images of the new permits.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 3 May 2021
Resolved
Vessel's posted emergency instructions were missing a page. Provide a full set of emergency instructions for the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 12 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2020
Resolved
Must have radios inspected by FCC license inspector and issued Radio Safety Certificate. Restricted to operations no more than 1000 feet from shore.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2020
Resolved 13 July 2020
Resolution: FCC document emailed to CG MI...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2020
Resolved
Must put face plates on all electrical outlets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 3 June 2020
Resolution: Verified by emailed photos
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2020
Resolved
Must have alcohol test strips on board to provide post casualty alcohol testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 3 June 2020
Resolution: Verified by email photos
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2020
Resolved
Must remove bare wire from J box located on port side of engine space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 3 June 2020
Resolution: verified by email
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 June 2020
Resolved
Must cover open sections of aft engine space bulkheads where blowers were removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 3 June 2020
Resolution: verified email photo evidence.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 October 2019
Resolved
Repair/replace the vent covers for the engine room vents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2019
Resolution: Replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 October 2019
Resolved
Repair the identified faulty emergency light in the aft berthing area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2019
Resolution: Repaired.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 October 2019
Resolved
Complete proper training of all crew on the operation of the fixed fire fighting system and satisfactorily complete a fire drill in the presence of a Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2019
Resolution: Drill SAT.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 8 October 2019
Resolved
Provide a PA system speaker or general alarm in all berthing areas below the pilot house deck that can be operated from the pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 1 June 2020
Resolution: Def corrected while on annual exam...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Remove all wire nuts in pilot house and make all wire connections in accordance with 46 CFR 183.340(g).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 11 October 2019
Resolution: Cleaned up wire nuts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Replace the electrical socket in the vecinity of the galley sink with a GFCI socket.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 11 October 2019
Resolution: Not required - ABYC rule for wiring.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2019
Resolved
Provide labeling on both sides of all emergency exits that states "Emergency Exit. Keep Clear."
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 11 October 2019
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Provide an up-to-date one-line diagram of the A/C electrical system on board the vessel. To be completed within 90 days.
Action required: 705 - Other - as specified
Due 6 January 2020
Resolved 1 June 2020
Resolution: Def corrected while on annual exam...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2019
Resolved
Replace stbd MDE J-box on stbd side of engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 24 April 2019
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2019
Resolved
Wiring splices shall be in a J-boxs. Properly splice wires on port and starboard outboard of main engines.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 24 April 2019
Resolution: Properly completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2019
Resolved
Wiring shall be as high out of the bilge as possible. Fix stbd side wiring in bilge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 24 April 2019
Resolution: Mounted up out of bilge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 April 2019
Resolved
Replace broken window on port side of bridge.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 24 April 2019
Resolution: Replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 April 2019
Resolved
Log monthly EPIRB test.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 24 April 2019
Resolution: Logged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2019
Resolved
Prove proper operation of bilge system.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2019
Resolved
Repair cooling water system on port MDE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2019
Resolved 24 April 2019
Resolution: Repaired and tested underway.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018
Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 March 2021
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 June 2018
Resolved
Provide proof of enrollment in drug testing program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2018
Fire Fighting › Fire Hoses › Condition
Issued 18 June 2018
Resolved
Replace damaged fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2018
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 18 June 2018
Resolved
Replace damaged window.
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 25 June 2018
Communications › Visual Communication › Signalling Lamp
Issued 18 June 2018
Resolved
Repair/replace masthead light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 25 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2018
Resolved
Clean up wiring in wheelhouse to minimize fire risk.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 25 June 2018
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 June 2018
Resolved
Provide emergency instruction list.
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 25 June 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 March 2017
Resolved
Provide valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 14 April 2017
Lifesaving › Lifebuoys › Serviceable
Issued 24 March 2017
Resolved
Repair or replace damaged ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 29 March 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2017
Resolved
Replace expired first aid kit materials.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 29 March 2017
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2017
Resolved
Complete required hull and internal structural exam IAW 46 CFR 176.600(c)(1) (prior to carrying passengers)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 June 2016
Resolved
Complete drills in presence of USCG Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Satisfactory fire and abandon ship drills conducted in MI presence.
Communications › Radio Communications › EPIRB
Issued 2 June 2016
Resolved
Prior to carrying pax on an oceans route, relocate EPIRB to float free location.
Action required: 705 - Other - as specified
Resolved 16 June 2016
Resolution: Verified EPIRB installed in float free location.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 2 June 2016
Resolved
Provide primary lifesaving (liferaft) for an additional 25 persons prior to carrying more than 25 total persons on an oceans route.
Action required: 705 - Other - as specified
Resolved 16 June 2016
Resolution: Verified all liferafts installed IAW COI.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 2 June 2016
Resolved
Repair excessive fire pump leak
Action required: 705 - Other - as specified
Due 3 July 2016
Resolved 16 June 2016