MAURY USCG vessel records
← All vessels

FISHERMAN III

Built
1959
Last inspected
3 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD5392
Flag
UNITED STATES
Maury page id
psix-43703

Documentation record

Registered dimensions (L × B × D)57.4 ft × 19.4 ft × 4.6 ft
Registered tonnagegross 33 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 2 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 62 deficiencies with the resolution recorded against each, 26 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA ADVENTURE 80 Passenger (Inspected) · MISLE 301214 · 23 September 2017 · activity 6273447

Inspection history · 25

3 March 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8319493
28 August 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8220078
8 August 2025 Deficiency Check · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8203002
18 July 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8188789
3 March 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8130361
18 July 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7961575
25 June 2024 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7911741
27 September 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7799605
17 May 2023 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684456
18 October 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7579991
1 July 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7797154
1 June 2022 In-Service Inspection · Internal Structural Exam · Hull Examination · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7453412
14 February 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7396374
20 July 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7262008
26 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7207549
27 May 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6962046
23 January 2020 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6881950
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838984
27 March 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6650289
2 May 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6403913
14 February 2018 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6355227
23 September 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6273447
27 February 2017 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6094030
30 March 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5843591
27 January 2016 Internal Structural Exam · Hull Examination · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813561

Deficiency record · 62

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 No resolution recorded
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Vessel has new crew that have not conducted drills.46 CFR 185.52
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 No resolution recorded
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Vessel has new crew that have not conducted drills. 46 CFR 185.52
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 No resolution recorded
Each survival craft must be: (1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Painter weak link has no service or documentation attesting to breaking strength.46 CFR 180.130
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 No resolution recorded
Each survival craft required on a vessel by this part must meet one of the following: (2) For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. -01 Life float doesn’t meet 160.027 with punctures in exterior. -Additionally, other life floats required to be cleaned to facilitate further inspection. -Hi Visibility tape is required for all life float
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 28 August 2025 No resolution recorded
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel rep stated they had two new hires but could not provide documents attesting to drug test or randomized drug testing program. Vessel has adequate crew without two new members. Must provide documentation prior to them working aboard vessel in a commercial setting.46 CFR 16.201
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2025 No resolution recorded
A vessel must be provided with bilge pumps. Not more than 49 passengers, not more than 65 ft bilge pumps required 1 fixed power pump (10 GPM) and 1 portable hand pump (10 GPM). Fixed bilge pump did not remove water from bilge at a rate of 10 GPM.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025 No resolution recorded
A suitable metal marine type strainer meeting the requirements of the engine manufacturer must be fitted in the fuel supply line in the engine compartment. Excessive buildup of residue on racor fuel filters
Action required: 701 - Prior to carriage of passengers/cargo
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 28 August 2025 No resolution recorded
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilges held excessive oil and debris.
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 August 2025 No resolution recorded
Bilge high level alarms. On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. One of the six visual bilge alarms at the operating station was not operating.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025 No resolution recorded
- Remove all dead end wires in wheelhouse, engine room and forepeak. - Fuse panel in wheelhouse was found with multiple areas of corrosion creating an electrical hazard. Remove corrosion. - Fuse was missing from cable to bus bar creating an electrical hazard. Remove cable if not in use. - Marine grade wires must be used in electrical installations. Non marine grade wiring was found in wheelhouse installations. - Battery in wheelhouse was found with a build up of corrosion. Clean battery. -Amazon power strip was found powering two Inverters to the radio installations. Hard wire in inverters if approved in electrical plan. Remove power strip. - Breaker panels were mostly found with illegible labels if any were present. Label all breaker panels. 2 breakers were found missing in the forward lounge. Either replace or put blanks in as approved in electrical plans that will be submitted. - Receptacle was found broken in wheelhouse. Replace receptacle labeled "side". - Wiring was found hanging from the deck into the bilges with broken. Reattach above the bilges. - Generator control box was found open with wiring exposed. Remove zip tie and demonstrate proper functionality
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025 No resolution recorded
Electrical Installation does not appear to have been reviewed or approved by the cognizant OCMI as required. Submit electrical plans in accordance with PEG E2-23 to the cognizant OCMI for review and approval. Temporary repair of foam was found where the deck meets the stem. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 August 2025 No resolution recorded
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly. EPIRB requires monthly tests and to be logged
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2025 No resolution recorded
Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion[1]resistant clip.The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the water light to be quickly disconnected from the ring life buoy. Life ring buoy 3ft waterlight line requires replace along with a installation of a corrosion resistant clip.
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 August 2025 No resolution recorded
Temporary repair of foam was found where the deck meets the stem. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 August 2025 No resolution recorded
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Lifejacket placard covered with television. Also need a secondary placard for donning instructions for second type of lifejacket.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 August 2025 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation. Provide copy of Certificate of documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 September 2025
Resolution: Vessel has a valid COD
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025 No resolution recorded
Electrical equipment exposed to the weather must be watertight. PA system on cabin overhead has wiring spliced together with electrical tape. Connection needs to occur in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025 No resolution recorded
Permission for repairs and alterations. Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to cognizant [name withheld] alterations must be approved by the OCMI before work is started. Hydraulic lines to mechanical anchor windlass were replaced without notification to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 August 2025 No resolution recorded
Guards for exposed hazards. An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Guard on port main diesel engine incorrectly installed leaving rotating machinery exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 August 2025 No resolution recorded
Watertight integrity. A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends at least 12 inches above the weather deck. Hatch used to connect shore power cable to vessel shore power junction box located in engine room is not weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 August 2025 No resolution recorded
Penetrations and openings in watertight bulkheads in a vessel less than a 100 gross tons. Penetrations and openings in watertight bulkheads must – (2) Have means to make them watertight. Several through hull fittings in watertight bulkheads located in lounge and forward peak were not properly sealed failing to make them watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2025 No resolution recorded
FCC Safety radiotelephony was expired, FCC station authorization was not on board, and operator did not have a valid Marine Radio Operator Permit. Vessel did not have light list or tight tables available.
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 August 2025 No resolution recorded
Vessel did not have light list or tight tables available.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2025 No resolution recorded
Employer should provide EAP to all crew members and have an information display. Vessel did not have an EAP display on board nor did they provide documents attesting to training.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 August 2025 No resolution recorded
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel has not completed the annual exam in specified time period.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 7 May 2025 Resolved
Aft engine room STBD side top corner frame had rotted from deck clamp down 8 in. deck is soft in this area. Material will need to be removed for further inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2025
Resolution: Deck and frames have been replaced. While fuel tanks were replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 May 2025 Resolved
Discovered wasted butt block port side behind fuel tank. Approved temp repair. Pull and examine fasteners in area and replace butt block next dry dock. Next drydock is dated 31Jan2026.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: Butt block replaced in DD
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 7 May 2025 Resolved
Discovered worm damage in fuel tank compartment, second frame from forward bulkhead STBD side near keel. Approved temp repair. Pull and examine fasteners in area. Replace frame next drydock dated 31Jan26.
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: Frame was cleaned to good wood, scarfed and insert glued/screwed in.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 May 2025 Resolved
Discovered 1/2 deep hole/bore in floor plank in tank compartment. Between 4th and 5th frame from forward bulkhead STBD side near keel. Approved temp repair. Pull and examine fasteners in area. Replace Plank next drydock dated 31Jan26.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: Floor plank found with significant worm damage and full replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 May 2025 Resolved
Noted in a 24 hour period while sitting at the dock, water level in tank compartment raised from .25" to almost 4". locate water ingress and repair.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: No excessive water ingress observed during sea trials following DD repairs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 May 2025 No resolution recorded
It was discovered bulkhead between Tank Compartment and Lazarette was not water tight. After reviewing subdivision calculations bulk head is required to be water tight. Make bulkhead water tight.
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 May 2025 Resolved
While underway discovered vessel making water in the aft STBD corner of lazarette. Water ingress was noted from chine up to 7th-8th plank. Pull and Examine fasteners in area. make repairs to make watertight.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2025
Resolution: Transom structure repaired with new structure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025 No resolution recorded
Vessel must schedule in-the-water internal structural exam with Sector San Diego as part of concentrated wooden vessel inspection campaign to verify condition of vessel's hull. email [email withheld] to schedule. Must be completed prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 July 2024 Resolved
Pre-engineered fixed gas fire extinguishing systems must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Upon testing, port main engine was not automatically shut down by the system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2024
Resolved 19 July 2024
Resolution: Verified satisfactory operation of the system.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 July 2024 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection from personnel injury. Belt guard was exposed on port main engine and must have suitable cover.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 24 July 2024
Resolution: Received picture confirmation of newly installed guards.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 July 2024 Resolved
The materials used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1); fuel tanks constructed of steel with a capacity over 150 gallons shall have a minimum thickness of 0.1793 inches (MSG7). Heavy scaling rust on both port and STBD steel fuel tanks was observed on all accessible sides of the tanks, remaining steel material is unknown without further testing/inspection. Provide plan to local OCMI with one of the following options: NDT/gauge thickness of tanks, remove tanks for further inspection and hydrostatic testing, or replace tanks. Replacement of tanks require USCG construction oversight to include plan approval. Must be addressed prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
Resolution: Fuel tanks constructed and tested. witnessed by OCMI.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 July 2024 Resolved
The materials used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1); fuel tanks constructed of steel with a capacity over 150 gallons shall have a minimum thickness of 0.1793 inches (MSG7). Heavy scaling rust on both port and STBD steel fuel tanks was observed on all accessible sides of the tanks, remaining steel material is unknown without further testing/inspection. Provide plan to local OCMI with one of the following options: NDT/gauge thickness of tanks, remove tanks for further inspection and hydrostatic testing, or replace tanks. Replacement of tanks require USCG construction oversight to include plan approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2024
Resolved 16 June 2025
Resolution: Fuel tanks constructed and tested. witnessed by Sector San Diego.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2023 Resolved
On 27SEP2023 Vessel reported the fuel line rupturing on the generator resulting in the generator failing on 24SEP2023. Vessel made repairs to the generator but the repairs must be verified by a marine inspector prior to the vessel carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2023
Resolution: Attended Fisherman III dockside at Oceanside Harbor for Marine Casualty follow-up. Vessel reported generator failure due to a ruptured fuel line while at anchor and carrying passengers. Old fuel line was not available for visual inspection. New fuel line
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2023 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. There was no hydrostatic release to EPIRB mount at the time of the inspection. Must install prior to sailing beyond high seas marker.
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Prior to sailing beyond high seas marker.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired/replaced. Top life float in fwd stack is no longer in serviceable condition. Life float must be removed and destroyed.
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023 Resolved
All non metallic material in vital piping systems shall possess characteristics adequate for its intended service and environment. Two (02) sections of the overboard discharge non metallic piping for bilge system is questionable in material. Must show to the CG Marine Inspector that material is adequate in approved specifications or replace material with approved non metallic sections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 19 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 May 2023 Resolved
Exhaust piping on both main engines must be suitably insulated to prevent injuries. Need to install outer cover to insulation of exhaust piping to both main engines to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 19 June 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 October 2022 Resolved
On a vessel of at least 26 feet in length, visual and audible alarm must be provided at the operating station to indicate a high water level. 04 of 06 bilge alarms were found inoperable, the 02 that were found operational did not have an acceptable volume of an audible alarm. Water ingress observed in lazarette. Vessel operator must make necessary repairs to the satisfaction of the Coast Guard prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2022 Resolved
Fire detection and extinguishing systems. Fire detection and extinguishing systems must be installed in compliance with 181.400 through 181.420 of this chapter. 02 of 02 independent modular smoke detectors were found inoperable with the batteries removed. Owner to replace batteries and test smoke detectors to the satisfaction of the Coast Guard prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector identified water ingress through STBD rudder packing, Repair to the satisfaction of the Coast Guard prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Upon arrival for Annual Inspection, Owner /Operator informed Marine Inspector that STBD gear box was unable to engage the STBD Maine Diesel Engine in ahead or astern. Owner/Operator stated this casualty occurred on 14OCT2022, however, it was never reported to the Coast Guard. Make proper repairs to the satisfaction of the Coast Guard prior to operating.
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 June 2022 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members. Vessel upon entering the water from Dry Docking, experienced water ingress from the STBD aft engine room bilge from a seam, and STBD between frames three and four six feet outboard of keel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2022
Resolution: Vessel completed satisfactory repairs and satisfactory sea trial.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 June 2022 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members. Vessel upon entering the water from Dry Docking, experienced water ingress from the STBD aft engine room bilge from a seam, and STBD between frames three and four six feet outboard of keel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2022
Resolution: Vessel made temporary repair to satisfaction of MI in order to transit to home port to conduct permanent repairs. Changed 17c to 701c
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2021 Resolved
The bilge alarms for the forepeak and tank space are inopperable. Repair/replace the identified bilge alarms so that they produce an audible and visual alarm at the operating station. Rounds of these spaces must be conducted at least once every hour while the vessel is underway or at anchor until this deficiency is rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 1 June 2021
Resolution: Witnessed a satisfactory test of the bilge alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2020 Resolved
Repair all patches on bilge piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 9 June 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 May 2020 Resolved
Provide a valid FCC Radio Safety Telephony Certificate. Complete within ninety (90) days.
Action required: 705 - Other - as specified
Due 25 August 2020
Resolved 25 August 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2020 Resolved
Replace all expired items within the first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 9 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 March 2019 Resolved
Renew both port and starboard side nav lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 23 April 2019
Resolution: Vessel rep replaced both side nav lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2019 Resolved
Renew failed valve in bilge manifold system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 23 April 2019
Resolution: Vessel rep replaced failed valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2019 Resolved
Renew flexible hose bilge overboard piping.
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Hose was reploaced on the spot.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 27 February 2017 Resolved
Provide up-to-date FCC Station License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2017
Resolved 28 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 February 2017 Resolved
Conduct acceptable safety drills in pressence of CG MI.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 8 March 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 February 2017 Resolved
Provide 03 adult PFDs. Passenger count reduced to 49 until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 8 March 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 30 March 2016 Resolved
Provide 3 adult lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 May 2016
Resolution: Verified proper count of lifejackets onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 March 2016 Resolved
Provide new battery for floating waterlight
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 2 May 2016
Resolution: Verified install of proper batteries.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 March 2016 Resolved
Provide new lifering line
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Resolution: Verified install of new lifeline
Communications › Radio Communications › EPIRB
Issued 30 March 2016 Resolved
Provide float free arrangement for EPIRB. Restricted to no more than 3nm.
Action required: 705 - Other - as specified
Resolved 31 March 2016
Resolution: Verified float free installation of EPIRB

Ownership record