MAURY USCG vessel records Sign in
← All vessels

FISHERMAN III

FISHERMAN III is a 1959 passenger vessel (inspected). The Coast Guard has recorded 102 inspections since 1985, most recently in March 2026, along with 175 deficiencies — 26 with no resolution recorded —, 3 operational controls and 4 casualty investigations between 2005 and 2022.

Records from 1985 to 2026. Most recent: inspection, 3 March 2026.

Built
1959
Last inspected
3 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5392
Flag
UNITED STATES
367157630
Maury page id
psix-43703

Inspections, by type

…with no type recorded19
Years with a record 40 calendar years (1985–2026)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.4 ft × 19.4 ft × 4.6 ft
Registered tonnagegross 33 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD5392MMSI 367157630 · active · compulsorily equipped · granted 8 December 2016, expires 29 December 2026
WDC8647MMSI 367090790 · expired · compulsorily equipped · granted 3 February 2006, cancelled 9 April 2016
WAP6673MMSI not assigned · expired · voluntarily equipped · granted 22 September 1995, cancelled 21 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA ADVENTURE 80 Passenger (Inspected) · MISLE 301214 · 23 September 2017 · activity 6273447SYNERGY Commercial Fishing Vessel · MISLE 194303 · 10 September 1999 · activity 157448

Inspection history · 102

3 March 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8319493
28 August 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8220078
8 August 2025 Deficiency Check · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8203002
18 July 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8188789
3 March 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8130361
18 July 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7961575
25 June 2024 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7911741
27 September 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7799605
17 May 2023 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684456
18 October 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7579991
1 July 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7797154
1 June 2022 In-Service Inspection · Internal Structural Exam · Hull Examination · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7453412
14 February 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7396374
20 July 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7262008
26 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7207549
27 May 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6962046
23 January 2020 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6881950
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6838984
27 March 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6650289
2 May 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6403913
14 February 2018 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6355227
23 September 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6273447
27 February 2017 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6094030
30 March 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5843591
27 January 2016 Internal Structural Exam · Hull Examination · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813561
23 October 2015 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5749497
7 October 2015 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5802962
7 May 2014 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4852971
6 February 2012 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4239138
19 January 2011 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3929351
25 February 2009 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3423625
12 December 2008 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3378927
1 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3164904
13 April 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2907554
1 March 2007 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2869841
17 January 2007 Plan Review "T" Boat · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2857305
2 May 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2627274
23 January 2006 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2559903
11 June 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2391387
3 May 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2339039
28 April 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2047881
13 January 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1983515
17 September 2003 Type not recorded
No type recorded · USCGC PETREL (WPB 87350) · USCG Southwest District (CGD-SW) · Activity 1916913
1 September 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1901675
5 June 2003 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1810572
23 April 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1779021
27 March 2003 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1763416
14 February 2003 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1744722
14 August 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1661343
4 March 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1491038
22 February 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1488486
29 June 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1065431
8 June 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1065152
19 March 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370064
14 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461441
18 July 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1052283
1 May 2000 Re-Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1421859
13 March 2000 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1047398
31 January 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378926
10 September 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 157448
10 September 1999 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1423250
2 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 107525
5 March 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 801178
5 March 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372526
13 November 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429057
9 November 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 804963
6 November 1998 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 803696
29 April 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394971
23 March 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381183
1 July 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 777489
15 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368175
14 March 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213897
6 March 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1456467
15 April 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1430179
1 April 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1443690
19 March 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1430178
24 August 1995 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1363349
10 May 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1454226
17 March 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1419391
26 April 1994 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382754
24 February 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394065
21 April 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 827640
14 December 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 826228
6 May 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 946110
9 May 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 920583
26 April 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1236500
14 September 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 919183
7 September 1990 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214995
10 May 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225438
27 June 1989 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 890674
10 April 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887778
31 March 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 889364
16 March 1988 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1030281
16 February 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1020873
15 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1002740
12 May 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1022578
26 March 1987 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1017295
4 February 1987 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1007213
23 January 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1009652
6 May 1986 Credit Drydock · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1308288
12 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 974754
7 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976576

Deficiency record · 175

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 No resolution recorded
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Vessel has new crew that have not conducted drills.46 CFR 185.52
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 No resolution recorded
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Vessel has new crew that have not conducted drills. 46 CFR 185.52
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 No resolution recorded
Each survival craft must be: (1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Painter weak link has no service or documentation attesting to breaking strength.46 CFR 180.130
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2025 No resolution recorded
Each survival craft required on a vessel by this part must meet one of the following: (2) For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. -01 Life float doesn’t meet 160.027 with punctures in exterior. -Additionally, other life floats required to be cleaned to facilitate further inspection. -Hi Visibility tape is required for all life float
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 28 August 2025 No resolution recorded
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel rep stated they had two new hires but could not provide documents attesting to drug test or randomized drug testing program. Vessel has adequate crew without two new members. Must provide documentation prior to them working aboard vessel in a commercial setting.46 CFR 16.201
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2025 No resolution recorded
A vessel must be provided with bilge pumps. Not more than 49 passengers, not more than 65 ft bilge pumps required 1 fixed power pump (10 GPM) and 1 portable hand pump (10 GPM). Fixed bilge pump did not remove water from bilge at a rate of 10 GPM.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025 No resolution recorded
A suitable metal marine type strainer meeting the requirements of the engine manufacturer must be fitted in the fuel supply line in the engine compartment. Excessive buildup of residue on racor fuel filters
Action required: 701 - Prior to carriage of passengers/cargo
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 28 August 2025 No resolution recorded
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilges held excessive oil and debris.
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 August 2025 No resolution recorded
Bilge high level alarms. On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. One of the six visual bilge alarms at the operating station was not operating.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025 No resolution recorded
- Remove all dead end wires in wheelhouse, engine room and forepeak. - Fuse panel in wheelhouse was found with multiple areas of corrosion creating an electrical hazard. Remove corrosion. - Fuse was missing from cable to bus bar creating an electrical hazard. Remove cable if not in use. - Marine grade wires must be used in electrical installations. Non marine grade wiring was found in wheelhouse installations. - Battery in wheelhouse was found with a build up of corrosion. Clean battery. -Amazon power strip was found powering two Inverters to the radio installations. Hard wire in inverters if approved in electrical plan. Remove power strip. - Breaker panels were mostly found with illegible labels if any were present. Label all breaker panels. 2 breakers were found missing in the forward lounge. Either replace or put blanks in as approved in electrical plans that will be submitted. - Receptacle was found broken in wheelhouse. Replace receptacle labeled "side". - Wiring was found hanging from the deck into the bilges with broken. Reattach above the bilges. - Generator control box was found open with wiring exposed. Remove zip tie and demonstrate proper functionality
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025 No resolution recorded
Electrical Installation does not appear to have been reviewed or approved by the cognizant OCMI as required. Submit electrical plans in accordance with PEG E2-23 to the cognizant OCMI for review and approval. Temporary repair of foam was found where the deck meets the stem. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 August 2025 No resolution recorded
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly. EPIRB requires monthly tests and to be logged
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2025 No resolution recorded
Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion[1]resistant clip.The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the water light to be quickly disconnected from the ring life buoy. Life ring buoy 3ft waterlight line requires replace along with a installation of a corrosion resistant clip.
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 August 2025 No resolution recorded
Temporary repair of foam was found where the deck meets the stem. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 August 2025 No resolution recorded
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Lifejacket placard covered with television. Also need a secondary placard for donning instructions for second type of lifejacket.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 August 2025 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation. Provide copy of Certificate of documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 September 2025
Resolution: Vessel has a valid COD
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2025 No resolution recorded
Electrical equipment exposed to the weather must be watertight. PA system on cabin overhead has wiring spliced together with electrical tape. Connection needs to occur in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2025 No resolution recorded
Permission for repairs and alterations. Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to cognizant [name withheld] alterations must be approved by the OCMI before work is started. Hydraulic lines to mechanical anchor windlass were replaced without notification to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 August 2025 No resolution recorded
Guards for exposed hazards. An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Guard on port main diesel engine incorrectly installed leaving rotating machinery exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 August 2025 No resolution recorded
Watertight integrity. A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends at least 12 inches above the weather deck. Hatch used to connect shore power cable to vessel shore power junction box located in engine room is not weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 August 2025 No resolution recorded
Penetrations and openings in watertight bulkheads in a vessel less than a 100 gross tons. Penetrations and openings in watertight bulkheads must – (2) Have means to make them watertight. Several through hull fittings in watertight bulkheads located in lounge and forward peak were not properly sealed failing to make them watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2025 No resolution recorded
FCC Safety radiotelephony was expired, FCC station authorization was not on board, and operator did not have a valid Marine Radio Operator Permit. Vessel did not have light list or tight tables available.
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 August 2025 No resolution recorded
Vessel did not have light list or tight tables available.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2025 No resolution recorded
Employer should provide EAP to all crew members and have an information display. Vessel did not have an EAP display on board nor did they provide documents attesting to training.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 August 2025 No resolution recorded
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel has not completed the annual exam in specified time period.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 7 May 2025 Resolved
Aft engine room STBD side top corner frame had rotted from deck clamp down 8 in. deck is soft in this area. Material will need to be removed for further inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2025
Resolution: Deck and frames have been replaced. While fuel tanks were replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 May 2025 Resolved
Discovered wasted butt block port side behind fuel tank. Approved temp repair. Pull and examine fasteners in area and replace butt block next dry dock. Next drydock is dated 31Jan2026.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: Butt block replaced in DD
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 7 May 2025 Resolved
Discovered worm damage in fuel tank compartment, second frame from forward bulkhead STBD side near keel. Approved temp repair. Pull and examine fasteners in area. Replace frame next drydock dated 31Jan26.
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: Frame was cleaned to good wood, scarfed and insert glued/screwed in.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 May 2025 Resolved
Discovered 1/2 deep hole/bore in floor plank in tank compartment. Between 4th and 5th frame from forward bulkhead STBD side near keel. Approved temp repair. Pull and examine fasteners in area. Replace Plank next drydock dated 31Jan26.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: Floor plank found with significant worm damage and full replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 May 2025 Resolved
Noted in a 24 hour period while sitting at the dock, water level in tank compartment raised from .25" to almost 4". locate water ingress and repair.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 August 2025
Resolution: No excessive water ingress observed during sea trials following DD repairs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 May 2025 No resolution recorded
It was discovered bulkhead between Tank Compartment and Lazarette was not water tight. After reviewing subdivision calculations bulk head is required to be water tight. Make bulkhead water tight.
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 May 2025 Resolved
While underway discovered vessel making water in the aft STBD corner of lazarette. Water ingress was noted from chine up to 7th-8th plank. Pull and Examine fasteners in area. make repairs to make watertight.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2025
Resolution: Transom structure repaired with new structure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2025 No resolution recorded
Vessel must schedule in-the-water internal structural exam with Sector San Diego as part of concentrated wooden vessel inspection campaign to verify condition of vessel's hull. email [email withheld] to schedule. Must be completed prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 July 2024 Resolved
Pre-engineered fixed gas fire extinguishing systems must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Upon testing, port main engine was not automatically shut down by the system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2024
Resolved 19 July 2024
Resolution: Verified satisfactory operation of the system.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 July 2024 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection from personnel injury. Belt guard was exposed on port main engine and must have suitable cover.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 24 July 2024
Resolution: Received picture confirmation of newly installed guards.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 July 2024 Resolved
The materials used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1); fuel tanks constructed of steel with a capacity over 150 gallons shall have a minimum thickness of 0.1793 inches (MSG7). Heavy scaling rust on both port and STBD steel fuel tanks was observed on all accessible sides of the tanks, remaining steel material is unknown without further testing/inspection. Provide plan to local OCMI with one of the following options: NDT/gauge thickness of tanks, remove tanks for further inspection and hydrostatic testing, or replace tanks. Replacement of tanks require USCG construction oversight to include plan approval. Must be addressed prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
Resolution: Fuel tanks constructed and tested. witnessed by OCMI.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 July 2024 Resolved
The materials used and the minimum thickness allowed in the construction of independent fuel tanks shall be as indicated in Table 182.20-25(a)(1); fuel tanks constructed of steel with a capacity over 150 gallons shall have a minimum thickness of 0.1793 inches (MSG7). Heavy scaling rust on both port and STBD steel fuel tanks was observed on all accessible sides of the tanks, remaining steel material is unknown without further testing/inspection. Provide plan to local OCMI with one of the following options: NDT/gauge thickness of tanks, remove tanks for further inspection and hydrostatic testing, or replace tanks. Replacement of tanks require USCG construction oversight to include plan approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2024
Resolved 16 June 2025
Resolution: Fuel tanks constructed and tested. witnessed by Sector San Diego.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2023 Resolved
On 27SEP2023 Vessel reported the fuel line rupturing on the generator resulting in the generator failing on 24SEP2023. Vessel made repairs to the generator but the repairs must be verified by a marine inspector prior to the vessel carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2023
Resolution: Attended Fisherman III dockside at Oceanside Harbor for Marine Casualty follow-up. Vessel reported generator failure due to a ruptured fuel line while at anchor and carrying passengers. Old fuel line was not available for visual inspection. New fuel line
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2023 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. There was no hydrostatic release to EPIRB mount at the time of the inspection. Must install prior to sailing beyond high seas marker.
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Prior to sailing beyond high seas marker.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired/replaced. Top life float in fwd stack is no longer in serviceable condition. Life float must be removed and destroyed.
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023 Resolved
All non metallic material in vital piping systems shall possess characteristics adequate for its intended service and environment. Two (02) sections of the overboard discharge non metallic piping for bilge system is questionable in material. Must show to the CG Marine Inspector that material is adequate in approved specifications or replace material with approved non metallic sections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 19 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 May 2023 Resolved
Exhaust piping on both main engines must be suitably insulated to prevent injuries. Need to install outer cover to insulation of exhaust piping to both main engines to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 19 June 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 October 2022 Resolved
On a vessel of at least 26 feet in length, visual and audible alarm must be provided at the operating station to indicate a high water level. 04 of 06 bilge alarms were found inoperable, the 02 that were found operational did not have an acceptable volume of an audible alarm. Water ingress observed in lazarette. Vessel operator must make necessary repairs to the satisfaction of the Coast Guard prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2022 Resolved
Fire detection and extinguishing systems. Fire detection and extinguishing systems must be installed in compliance with 181.400 through 181.420 of this chapter. 02 of 02 independent modular smoke detectors were found inoperable with the batteries removed. Owner to replace batteries and test smoke detectors to the satisfaction of the Coast Guard prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector identified water ingress through STBD rudder packing, Repair to the satisfaction of the Coast Guard prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Upon arrival for Annual Inspection, Owner /Operator informed Marine Inspector that STBD gear box was unable to engage the STBD Maine Diesel Engine in ahead or astern. Owner/Operator stated this casualty occurred on 14OCT2022, however, it was never reported to the Coast Guard. Make proper repairs to the satisfaction of the Coast Guard prior to operating.
Action required: 30 - Ship detained
Resolved 17 May 2023
Resolution: Verified at COI renewal exam; [name withheld]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 June 2022 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members. Vessel upon entering the water from Dry Docking, experienced water ingress from the STBD aft engine room bilge from a seam, and STBD between frames three and four six feet outboard of keel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2022
Resolution: Vessel completed satisfactory repairs and satisfactory sea trial.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 June 2022 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members. Vessel upon entering the water from Dry Docking, experienced water ingress from the STBD aft engine room bilge from a seam, and STBD between frames three and four six feet outboard of keel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2022
Resolution: Vessel made temporary repair to satisfaction of MI in order to transit to home port to conduct permanent repairs. Changed 17c to 701c
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2021 Resolved
The bilge alarms for the forepeak and tank space are inopperable. Repair/replace the identified bilge alarms so that they produce an audible and visual alarm at the operating station. Rounds of these spaces must be conducted at least once every hour while the vessel is underway or at anchor until this deficiency is rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 1 June 2021
Resolution: Witnessed a satisfactory test of the bilge alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2020 Resolved
Repair all patches on bilge piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 9 June 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 May 2020 Resolved
Provide a valid FCC Radio Safety Telephony Certificate. Complete within ninety (90) days.
Action required: 705 - Other - as specified
Due 25 August 2020
Resolved 25 August 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2020 Resolved
Replace all expired items within the first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 9 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 March 2019 Resolved
Renew both port and starboard side nav lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 23 April 2019
Resolution: Vessel rep replaced both side nav lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2019 Resolved
Renew failed valve in bilge manifold system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 23 April 2019
Resolution: Vessel rep replaced failed valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2019 Resolved
Renew flexible hose bilge overboard piping.
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Hose was reploaced on the spot.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 27 February 2017 Resolved
Provide up-to-date FCC Station License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2017
Resolved 28 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 February 2017 Resolved
Conduct acceptable safety drills in pressence of CG MI.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 8 March 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 February 2017 Resolved
Provide 03 adult PFDs. Passenger count reduced to 49 until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 8 March 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 30 March 2016 Resolved
Provide 3 adult lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 May 2016
Resolution: Verified proper count of lifejackets onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 March 2016 Resolved
Provide new battery for floating waterlight
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 2 May 2016
Resolution: Verified install of proper batteries.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 March 2016 Resolved
Provide new lifering line
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Resolution: Verified install of new lifeline
Communications › Radio Communications › EPIRB
Issued 30 March 2016 Resolved
Provide float free arrangement for EPIRB. Restricted to no more than 3nm.
Action required: 705 - Other - as specified
Resolved 31 March 2016
Resolution: Verified float free installation of EPIRB
Electrical › Electrical Distribution System (service) › Cable
Issued 7 October 2015 Resolved
Replace STBD starter cable as original that had chaffed through the insulation which intern shorted the starter selynoid.
Condition: Improper/Lack of Maintenance
Due 7 October 2015
Resolved 7 October 2015
Resolution: Replaced STBD starter cable and the starter selynoid.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 February 2012 Resolved
Provide consortium proof of DAPI enrollment for 2012 and list of crew members enrolled for 2012.
Action required: 705 - Other - as specified
Due 29 March 2012
Resolved 9 March 2012
Resolution: Received copies of consortium proof of enrollment and current active employee list.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 February 2012 Resolved
Prove proper operation of fireboy shutdown for generator.
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 29 February 2012
Resolution: Cable adjusted on generator governor, fireboy shutdown of generator sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 25 February 2009 Resolved
Vsl is restricted from carrying passengers due to shut down for the generator
Action required: 705 - Other - as specified
Resolved 2 April 2009
Resolution: Pressure switch as been renewed, and tested satisfactory
Engineering › Bilge Water Management System › Valve
Issued 12 December 2008 Resolved
Pull two fwd valves for inspection (sewage, gray water)
Action required: 705 - Other - as specified
Resolved 5 February 2009
Resolution: Valves are satisfactory
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 April 2008 Resolved
Repair port fuel shut off valve.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2008
Resolved 3 April 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 1 April 2008 Resolved
Repair emergency lighting.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2008
Communications › Audible Communications › Horn/Whistle
Issued 1 April 2008 Resolved
Repair ship horn.
Due 20 April 2008
Resolved 17 April 2008
Lifesaving › Lifeboat Equipment › Binnacle/Compass
Issued 1 April 2008 Resolved
Repair compass light.
Condition: Improper Installation
Due 20 April 2008
Resolved 17 April 2008
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 1 April 2008 Resolved
Provide eyewash solution.
Condition: Placed in Improper Service
Due 17 May 2008
Resolved 20 April 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 1 April 2008 Resolved
Prorvide a valve for bilge discharge at teh hull.
Condition: Improper Installation
Due 20 April 2008
Resolved 17 April 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 1 April 2008 Resolved
Install a mechanical ventilation closure for the air intake duct so that it will be a means to secure the air intake duct during the fire so that CO2 will not escape when deploy ( as opposed to the traditional meethod of stuffing fish bags into the ventilation).
Condition: Improper Installation
Due 30 September 2008
Resolved 23 February 2009
Resolution: All vent now have the proper closures, they are on a clasp and are satisfactory
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 March 2007 Resolved
provide proof of pre- enrollment
Due 23 March 2007
Resolved 22 March 2007
Communications › Radio Communications › EPIRB
Issued 1 March 2007 Resolved
Replace EPIRB battery.
Condition: Improper/Lack of Maintenance
Due 23 March 2007
Resolved 22 March 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 1 March 2007 Resolved
Repair broken frame for one lifefloat.
Condition: Improper/Lack of Maintenance
Due 23 March 2007
Resolved 22 March 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 1 March 2007 Resolved
Repair holes for one lifefloat.
Due 23 March 2007
Resolved 22 March 2007
Lifesaving › Rescue Boat › Boarding Ladder
Issued 1 March 2007 Resolved
Provide a sturdy ladder
Condition: Unknown
Due 23 March 2007
Resolved 22 March 2007
Construction/Loadline › Hull › Side Shell
Issued 17 January 2007 Resolved
Caulk port and starboard side, exposed areas
Action required: 705 - Other - as specified
Resolved 7 February 2007
Resolution: Vsl caulk all exposed seams.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 January 2007 Resolved
Treat angel hair on port and starboard side of the engine room shelf areas
Action required: 705 - Other - as specified
Resolved 7 February 2007
Resolution: Vsl treated angel hair on both sides.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 January 2007 Resolved
Dye test the starboard shaft.
Action required: 705 - Other - as specified
Resolved 7 February 2007
Resolution: Vsl had Driscolls test tailshaft, test sat
Fire Fighting › Grease Extraction Hood › General
Issued 17 January 2007 Resolved
Vsl needs to comply with CID policy letter # 20, vsl has 3 months to comply.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 13 April 2007
Resolution: Vsl complies with CID policy letter #20 and complies with Galley Grease Extraction hood policy for vsl under 65ft.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 May 2006 Resolved
Replace twelve (12) rejected adult lifejackets.
Condition: Improper/Lack of Maintenance
Due 10 May 2006
Resolved 3 May 2006
Communications › Radio Communications › EPIRB
Issued 3 May 2005 Resolved
Provide proof that the 406MHz EPIRB is registered with NOAA. Vessel restricted to voyages less than 3 miles from shore until corrected.
Due 18 May 2005
Resolved 3 May 2005
Communications › Radio Communications › EPIRB
Issued 3 May 2005 Resolved
Test and log EPIRB testing monthly.
Due 18 May 2005
Resolved 4 May 2005
Fire Fighting › Grease Extraction Hood › General
Issued 3 May 2005 Resolved
Clean galley grease trap/hood and ducting.
Due 18 May 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 May 2005 Resolved
Repair electrical outlet in lower stores (install cover).
Due 18 May 2005
Resolved 4 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2005 Resolved
Provide globe for light in lower stores, and ensure properly mounted.
Due 18 May 2005
Resolved 4 May 2005
Fire Fighting › Nozzles › Number
Issued 3 May 2005 Resolved
Provide nozzle for fire hose.
Due 18 May 2005
Resolved 4 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2005 Resolved
Remove dead-end wire in E/R bulkhead and seal penetration.
Due 18 May 2005
Resolved 4 May 2005
Engineering › Bilge Water Management System
Issued 28 April 2004 Resolved
Remove excess oil in bilge in engine room IAW 46CFR176.830(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 7 May 2004
Engineering › Steering Gear System
Issued 28 April 2004 Resolved
Tighten and PMS all mounting bolts at the base of steering gear system IAW 46CFR176.800 LEGACY COMPONENT DESC: Bracket/Clamp
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 7 May 2004
Communications › Radio Communications › EPIRB
Issued 28 April 2004 Resolved
Provide proof of NOAA registration for EPIRB IAW 47CFR80.106(e)(f). Deficiency restricts vessel to lakes, bays and sounds route.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 28 April 2004
Resolution: Received fax from Owners representative providing proof of NOAA registration.
Electrical › Electrical Distribution System (service)
Issued 27 March 2003 Resolved
Enclose breaker panel with dead front type IAW 46 CFR 183.330(b). LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 27 March 2003 Resolved
Replace corss over fuel pipe IAW 46 CFR 182.455(a). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 27 March 2003 Resolved
Renew retro tape on (1) identified adult PFD IAW 46 CFR 185.604(h). LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 27 March 2003 Resolved
Destroy and replace (2) identified adult PFDs IAW 46 CFR 180.71(a). LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Fire Fighting › Miscellaneous Items
Issued 27 March 2003 Resolved
Provide service report for fire extinguishers and fixed fire fighting system IAW 46 CFR 176.810(b).
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 23 April 2003
Electrical › Electrical Distribution System (service)
Issued 27 March 2003 Resolved
Provide metallic clamps every 24 inches in engineroom for overhead cables IAW 46 CFR 183. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Engineering
Issued 27 March 2003 Resolved
Couble clamp salt water suction hose for bait pump IAW 176.800(a).
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 27 March 2003 Resolved
Restencile lifejacket storage areas IAW 46 CFR 185.604(f). LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Engineering › Bilge Water Management System
Issued 14 August 2002 Resolved
Clean engine room bilge (remove excess oil) and provide receipt for disposal.
Action required: 705 - Other - as specified
Due 20 August 2002
Resolved 20 August 2002
Engineering
Issued 14 August 2002 Resolved
Provide starboard engine oil vent cap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2002
Resolved 20 August 2002
Engineering › Bilge Water Management System
Issued 14 August 2002 Resolved
Remove all excess oily rags/wipes from engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2002
Resolved 20 August 2002
Engineering › Fuel Oil Service System
Issued 7 March 2002 Resolved
Properly mark fuel cutoffs IAW46CFR185.608 LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Due 28 March 2002
Resolved 12 March 2002
Operations/Management › Navigation Safety
Issued 7 March 2002 Resolved
Replace bridge window LEGACY COMPONENT DESC: Navigation Underway, General
Condition: Damaged By Earlier Event
Due 12 April 2002
Resolved 26 March 2002
Operations/Management › Drills/Instruction
Issued 7 March 2002 Resolved
perform satisfactory man overboard drill. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 7 March 2002
Lifesaving › Buoyant Apparatus
Issued 7 March 2002 Resolved
Route/repair lifefloat extraction line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2002
Resolved 7 March 2002
Engineering › Fuel Oil Service System
Issued 7 March 2002 Resolved
Install proper vent screens on fuel tanks. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 28 March 2002
Resolved 7 March 2002
Stability › Watertight Integrity
Issued 7 March 2002 Resolved
Install skin valves on forepeak hull penetrations IAW 46CFR 177.350
Condition: Design Flaw
Due 12 April 2002
Resolved 26 March 2002
Engineering › Fuel Oil Service System › Hose
Issued 4 March 2002 Resolved
Double hose clamp fuel fill hoses.
Condition: Improper Installation
Due 9 March 2002
Resolved 7 March 2002
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 4 March 2002 Resolved
Renew hydraulic pump hose FWD port of ER.
Condition: Improper Installation
Due 9 March 2002
Resolved 7 March 2002
Construction/Loadline
Issued 29 June 2001 Resolved
Repair bilge alarm lights to work in conjunction with the proper compartment.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Engineering
Issued 8 June 2001 Resolved
Provide remote fuel shutoffs.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 8 June 2001 Resolved
Make bulkhead penetrations watertight.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Engineering
Issued 19 March 2001 Resolved
Replace stbd main diesel engine raw water cooling hose.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Engineering
Issued 19 March 2001 Resolved
Provide proper remote fuel shutoffs.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Construction/Loadline
Issued 19 March 2001 Resolved
Properly replace captive chains to hatches for forepeak and lazarette.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Construction/Loadline
Issued 19 March 2001 Resolved
Make bulkhead penetrations watertight.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Construction/Loadline
Issued 19 March 2001 Resolved
Replace PVC bilge suction line for FWD accomodation space with metal line.
Condition: Unknown
Due 19 March 2002
Resolved 20 August 2002
Lifesaving
Issued 19 March 2001 Resolved
Properly stencil number and type of life jackets on stowage bins and separate child from adult lifejackets.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Construction/Loadline
Issued 10 September 1999 Resolved
Repair all bilge flooding alarms on vessel prior to operating with passengers.
Condition: Unknown
Due 11 September 1999
Resolved 27 September 1999
Construction/Loadline
Issued 10 September 1999 Resolved
Make repairs to port forward rail prior to operating with passengers. (submit pictures; Before and after)
Condition: Unknown
Due 11 September 1999
Resolved 27 September 1999
Construction/Loadline
Issued 10 September 1999 Resolved
Submit repair proposal to [name withheld], CA prior to operating with passengers.
Condition: Unknown
Due 11 September 1999
Resolved 13 September 1999
Navigation
Issued 29 April 1998 Resolved
Replace unreadable emergency broadcast placard.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Construction/Loadline
Issued 29 April 1998 Resolved
Repair and demonstrate inoperative bilge high level alarms at accommodations, engine room and tank void spaces.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Accommodation/Occupational Safety
Issued 15 April 1997 Resolved
Refasten ladder top at fwd void.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Documentation
Issued 15 April 1997 Resolved
Provide on board copy of drug testing records and crew list; also copy of stability letter.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Construction/Loadline
Issued 15 April 1997 Resolved
Repair and prove proper operation of FWD void bilge alarm.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Fire Fighting
Issued 15 April 1997 Resolved
Properly service fire extinguishers and provide record of completion to USCG prior to embarking passengers.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Unknown
Issued 1 April 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 1 April 1996 Resolved
PROVE PROPER OPERATION OF WATERLIGHT ATTACHED TO BA. VESSEL LIMITED TO 45 PASSENGERS UNTIL REQUIREMENT CLEARED.
Condition: Unknown
Due 15 April 1996
Resolved 24 April 1996
Lifesaving
Issued 1 April 1996 Resolved
RENEW EXPIRED RED DISTRESS FLARES.
Condition: Unknown
Due 15 April 1996
Resolved 24 April 1996
Navigation
Issued 1 April 1996 Resolved
PROVE PROPER OPERATION OF STBD NAVIGATIONAL LIGHT, PRIOR TO NIGHT TIME OPERATIONS.
Condition: Unknown
Due 15 April 1996
Resolved 24 April 1996
Electrical
Issued 10 May 1995 Resolved
Prove proper operation of emergency lighting.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Lifesaving
Issued 10 May 1995 Resolved
Renew wasted weaklink attached to the lifefloat seapainter.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Documentation
Issued 10 May 1995 Resolved
Provide and post emergency procedures.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Engineering
Issued 10 May 1995 Resolved
Provide grounding strap between fuel fill pipe and tank.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Documentation
Issued 10 May 1995 Resolved
Provide proof of random drug testing program.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Engineering
Issued 10 May 1995 Resolved
Mark emergency fuel shut off valves.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Lifesaving
Issued 10 May 1995 Resolved
Provide lables for lifejacket storage containers.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Documentation
Issued 10 May 1995 Resolved
Provide and post vessel's stability letter.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Documentation
Issued 10 May 1995 Resolved
Provide valid FCC Compliance certificate.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Engineering
Issued 10 May 1995 Resolved
Provide flame screen on fuel tank vents.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 10 May 1995 Resolved
Provide lightbulbs and covers for below deck light fixtures.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Construction/Loadline
Issued 24 February 1994 Resolved
RENEW AS ORIGINAL, AREA ON FOWARD BULKHEAD, PORTSIDE OF F/O TANK COMPARTMENT AND ADJACENT SUPPORT FOR F/O TANK.
Condition: Unknown
Due 1 June 1994
Resolved 28 February 1994
Engineering
Issued 24 February 1994 Resolved
RENEW WITH PROPER MATERIAL, PORT AND STBD F/O TANK VENT, FLAME SCREENS.
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Construction/Loadline
Issued 7 September 1990 Resolved
INSTALL SEA VALVES FOR THE PORT AND STARBOARD THROUGH HULL FITTINGS OF THE EXISTING OVERBOARD DISCHARGE LINE FROM THE PORT & STARBOARD TOILETS.
Condition: Unknown
Due 7 September 1990
Resolved 7 September 1990
Unknown
Issued 7 September 1990 Resolved
PROVIDE AN APPROVED MARINE SANITATION DEVICE HOLDING TANK WITH A CAPACITY SATISFACTORY FOR 66 PERSONS ABOARD THE VESSEL.
Condition: Unknown
Due 7 September 1990
Resolved 7 September 1990
Documentation
Issued 10 April 1989 Resolved
PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Lifesaving
Issued 16 March 1988 Resolved
ATTACH BOUYANT APPARATUS TOGETHER WITH LINE.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Documentation
Issued 16 March 1988 Resolved
PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION ON BOARD THE VESSEL.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Construction/Loadline
Issued 16 March 1988 Resolved
SEAL HOLE IN FORWARD ENGINE COMPARTMENT BULKHEAD.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Lifesaving
Issued 16 March 1988 Resolved
PROVIDE A FLOAT LIGHT AND 60' LINE FOR RING BUOY.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Construction/Loadline
Issued 16 February 1988 Resolved
REPAIR LOOSE CAULKING IN WAY AT PORTSIDE JUST BELOW THE DECK GUNWALE FROM STERN TRANSOME EXTENDING THROUGH AMIDSHIP.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Unknown
Issued 16 February 1988 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Engineering
Issued 26 March 1987 Resolved
REPLACE BILGE OVERBOARD PEDROS WITH USCG APPROVED MATERIAL.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Electrical
Issued 26 March 1987 Resolved
INSTALL COVER ON VOLTAGE REGULATOR IN THE ENGINE COMPARTMENT.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987 Resolved
COVER PENETRATION OPENINGS IN AFT ENGINE COMPARTMENT BULKHEAD.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Lifesaving
Issued 26 March 1987 Resolved
REPLACE 3 PADDLES FOR LIFE FLOATS.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987 Resolved
TREAT WOOD IN AREAS WHERE ROT IS STARTING.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Lifesaving
Issued 26 March 1987 Resolved
MARK LIFE FLOAT PADDLES WITH VESSEL'S NAME.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Documentation
Issued 26 March 1987 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Fire Fighting
Issued 26 March 1987 Resolved
REPLACE NON-APPROVED PORTABLE FIRE EXTINGUISHERS WITH USCG APPROVED TYPE.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Deck/Cargo
Issued 23 January 1987 Resolved
SUBMIT BILGE DIAGRAMS FOR NEW BILGE SYSTEM.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Engineering
Issued 23 January 1987 Resolved
CAP OFF FUEL STRIPPING CONNECTION FITTING IN ER.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Construction/Loadline
Issued 23 January 1987 Resolved
SEAL HOLES IN TRANSVERSE WT BULKHEADS WHERE EXHAUST LINES PASS.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Engineering
Issued 23 January 1987 Resolved
RECONNECT FUEL SHUTOFF RODS.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Engineering
Issued 23 January 1987 Resolved
PROVIDE JUMPER LINES ON FUEL FILL CONNECTIONS.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Engineering
Issued 6 May 1986 Resolved
INSTALL METALLIC BILGE PIPING.
Condition: Unknown
Due 6 May 1986
Resolved 6 May 1986
Construction/Loadline
Issued 7 February 1985 Resolved
MAKE PORT SIDE 3RD COMPARTMENT AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985 Resolved
ACQUIRE (1) ADDITIONAL B-II FIRE EXTINGUISHER FOR ENGINE ROOM.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
ACQUIRE (3) ADULT LIFEJACKETS
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Construction/Loadline
Issued 7 February 1985 Resolved
MAKE PERMANENT REPAIRS TO PLANK STBD SIDE, 3RD COMPARTMENT, APPROX 2' ABOVETHE WATERLINE.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985

Casualty record · 4

11 June 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2391387
19 April 2012Routine · role: Involved in a Marine Casualty · activity 4291364
23 September 2017Routine · role: Involved in a Marine Casualty · activity 6273447
1 July 2022Routine · role: Involved in a Marine Casualty · activity 7797154
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.