Records from 1988 to 2026. Most recent: inspection, 15 July 2026.
Inspection history · 88
15 July 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8439126
29 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8416739
20 March 2026
Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8330268
25 August 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8217784
6 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8129084
9 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7914033
3 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7905901
20 March 2024
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7882565
6 June 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7706494
2 May 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7685086
27 April 2023
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7675935
26 August 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7544076
25 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7515842
3 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405350
16 August 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288066
10 June 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221189
8 April 2021
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7170618
23 September 2020
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7063806
16 April 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6939963
19 March 2020
Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6929216
10 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6808087
29 June 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743704
24 April 2019
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6669762
21 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6420463
25 April 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6399433
28 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112766
30 March 2016
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112770
16 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5834832
21 January 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5804384
1 December 2015
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5772774
13 October 2015
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5742509
10 August 2015
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5215785
7 August 2015
In-Service Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5742359
4 August 2014
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4945859
28 May 2014
DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4871916
20 May 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4862982
2 May 2014
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4848876
2 May 2014
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4860104
30 July 2009
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3550246
21 July 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3544189
13 July 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3533999
7 May 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3200220
11 February 2008
Hull Examination · Deficiency Check · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3145516
26 April 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2916372
26 April 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2916406
25 April 2007
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2911502
29 January 2007
Examination of Repairs · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2863197
25 January 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2863931
17 July 2006
Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2716258
12 June 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2677319
5 October 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2516768
3 August 2005
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2450011
20 July 2004
Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2138976
19 May 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2072518
13 November 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1947950
3 June 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1808424
6 May 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1787458
23 July 2002
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1650039
2 May 2002
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1611543
6 June 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1066139
4 May 2001
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410548
27 July 2000
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1379147
4 May 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1403121
11 August 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1402921
5 May 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1391004
28 May 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441386
27 August 1997
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1419820
1 May 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093554
6 May 1996
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1083097
31 August 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 872140
11 May 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917632
2 May 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1168672
31 August 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839641
11 May 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1142725
3 May 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1148236
31 August 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1270680
25 June 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1270182
22 May 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1263766
10 September 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1255537
19 June 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 893098
29 May 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 902906
24 July 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229456
29 May 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1213152
13 June 1989
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036912
7 February 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1341880
24 June 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1036674
15 June 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201783
10 June 1988
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1205229
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type.
Fire extinguishers throughout vessel do not have brackets required for CG approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2026
Resolved 21 August 2026
Resolution: Brackets replaced with approved type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 June 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected.
Air pressure gauges for throttles at bridge wings are unreadable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2026
Resolved 15 July 2026
Resolution: Air gauges replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 20 March 2026
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] pipe in port fwd engine compartment for bridal suite/ lower galley has a pinhole leak. Make permanent repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. There is a cracked electrical outlet located on the top deck aft starboard side. Replace cracked outlet.
CFR 183.01-15(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 25 August 2025
Resolution: Electrical outlet has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2024
Resolved
Aft swim platform railing system is missing hardware throughout and is pulling away from vessel structure. Replace/install all missing railing hardware.
Main deck aft STBD side embarking gate top railing is loose. Make repairs/tighten.
46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 9 May 2024
Resolution: Aft swim platform railing system and emarkation gate top railing have been restored properly.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 April 2023
Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. Vessel could not provide satisfactory evidence of required monthly service. Conduct monthly servicing of all portable extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew completed monthly service while in attendance.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 April 2023
Resolved
Electrical outlets found with open ground circuits. 5 in the bridle suite, 1 GFI in the 1st deck starboard head and 1 with an open neatral circuit at the workbench in the Engineroom. Properly wire all defective circuits.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: All effected outlets where removed and blanked off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2023
Resolved
Hoses on Both main engine R/W suction lines to the pump and the Bow Thruster PTO Actuator port main are deteriorated, renew all hoses.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: All hoses where renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 27 April 2023
Resolved
Hot water heaters (3) are wasted on the bottoms and the safety relief valves are not properly plumbed and could relieve in someone's face. Renew heaters and plumb IAW manufactures instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 6 June 2023
Resolution: Hot water heater was renewed and relief valve escape piping was properly routed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 27 April 2023
Resolved
Properly Label on both sides Escape hatch in Engineroom with 1 inch minimum letters "Escape Hatch Keep Clear" and all watertight doors "Watertight Door-Keep Closed"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2023
Resolution: sighted proper markings
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 April 2023
Resolved
Starboard aft loading gate is damagaged and does not latch. Repair Latch, gate must take load of 200lbs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: Gate was repaired by welding and gate latch was fabricated to lock.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2023
Resolved
Managers office was littered with empty cardboard boxes, several electrical outlets where missing covers and an extension cord was daisy chained into a UPS to provide power for a mini fridge. Remove fire hazards and repair electrical safety issues.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Ships crew removed all boxes, installed outlet covers, unhooked mini fridge and removed extension cords from space.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 July 2022
Resolved
The audible high level bilge alarms and the visual indicators for the two watertight doors at the flybridge operating station are inoperable. The vessel is restricted from the use of the flybridge operating station until all audible/visual alarms and indicators are operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 August 2022
Resolution: Inspector witnessed satisfactory operation of bilge high-level alarms and watertight door indicator lights on the flybridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2022
Resolved
The vessel's generators are capable of operating in parallel. 46 CFR 111.12(f) requires reverse power relays for each generator arranged for parallel operation. Prove proper operation of the reverse power relays and provide training for the crew on paralleling generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
Resolution: Witnessed satisfactory testing/operation of the reverese power relays for both port and starboard generators.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 July 2022
Resolved
Make repairs to copper piping leak directly above distribution panel in the steering space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2022
Resolved
Demonstrate that the electronic interlock will prevent parallel operation of the generators with shore power.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
Resolution: Inspector witnessed satisfactory operation of electronic interlock preventing parallel operation of generators w/ shore power.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021
Resolved
Properly mark Life Jackets with vessel name and replace retro reflective tape on same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 16 August 2021
Resolution: All jackets have been marded iaw applicable CFR
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 April 2021
Resolved
During vessel drydock and internal exam, in the starboard stern and corner area of vessel, there is damage discovered. The following are approx. estimates and will require submitted repair proposal for approval by OCMI prior to beginning repair. Appox. 4' x 7' hull plate is bowed and inset, two corner gusset brackets are bent, side longs bent/distorted, and a section of vertical channel is crushed. In the approx. same area on the deck, there is a section of floor joist bar with a broken weld pick up. Vessel shall submit repair plan to local OCMI for approval, complete repairs, and conduct testing with local OCMI prior to conducting operations with passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 May 2021
Resolved 23 April 2021
Resolution: All repairs, pick ups, and testing completed. DD/ISE credit issued.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 May 2019
Resolved
Repair/replace insulation in engine room overhead by stairs to satisfaction of attending Marine Inspector.
46CFR177.10-5
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 10 September 2019
Resolution: Received photos of new insulation install
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2019
Resolved
Remove flameable presurized cans from engine room space to satisfaction of attending Marine Inspector.
46CFR176.25-50(a)
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Flameable presurized cans were removed from engine room space to the satisfaction of attending Marine Inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 May 2019
Resolved
Repair/replace port engine exhaust lagging over flanged area to satisfaction of attending Marine Inspector.
46CFR182.20-20(a)
46CFR182.15-20(g)
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 10 September 2019
Resolution: Lagging has been fixed, added to exhaust flang
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2019
Resolved
Label breaker for shore power to satisfaction of attending Marine Inspector.
46CFR183.10-20(i)
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Shore power breaker was labeled to satisfaction of attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 May 2019
Resolved
Repair/replace WTD between lazarette and engine room to satisfaction of attending Marine Inspector.
46CFR176.25-5(a)(2)
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Quick acting WTD assembly was tighted and chalk tested to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2019
Resolved
Repair/replace grab line on two (2) life ring buoys to the satisfaction of attending Marine Inpector.
46CFR180.30
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Grab lines on the two (2) life ring buoys were repaired/replaced to the satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 May 2019
Resolved
Remove oil under starboard generator to the satisfaction of attending Marine Inspector.
46CFR176.25-50(b)
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Oil was removed from underneith starboard generator to the satisfaction of attending Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 April 2018
Resolved
Provide buoyant lifeline 60 feet 5/16".
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 21 May 2018
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 25 April 2018
Resolved
Hydro test air receivers to 1.5 MAWP or make available for internal exam.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 21 May 2018
Electrical › Electric Generation Source (service) › Conductor
Issued 25 April 2018
Resolved
Properly support electrical cables throughout vessel 24" on center.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 21 May 2018
Engineering › Thrusters › Piping
Issued 10 August 2015
Resolved
Repair leaking lubrication line to bow thruster. 46 CFR 182.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspectior
Electrical › Electrical Distribution System (emergency) › Cable
Issued 10 August 2015
Resolved
Properly terminate wiring hanging behind bulkhead panel on lower galley starboard side. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 10 August 2015
Resolved
Repair ladder from upper to lower galley. 46 CFR 177.254
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 August 2015
Resolved
Replace 2 missing lighting fixtures in lower galley. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspector.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 August 2015
Resolved
Replace plastic bands with metal bands every 24" in engine room as needed in support on overhead wiring in pump room. 46 CFR 183.10--20
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspector.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 August 2015
Resolved
Remount electrical junction box in lazarette. (near workbench) 46 CFR 183.01-5
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 August 2015
Resolved
Clean out one way check valve and (found screw holding up valve) and ensure proper operation of drain starboard side near generator. 46 CFR 176.5-5
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 21 September 2015
Resolution: Verified by marine inspector.
Engineering › Bilge Water Management System › Piping
Issued 28 May 2014
Resolved
Verify all bilge suctions operate properly. 46 CFR 182.25-5, 46 CFR 182.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2015
Resolved 9 June 2014
Resolution: All bilge suctions operational and tested in presence of USCG inspector.
Engineering › Steering Gear System › Bracket/Clamp
Issued 28 May 2014
Resolved
Repair Steering Stops. 46 CFR 185.20-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2015
Resolved 9 June 2014
Resolution: New steering stops welded into place. Sterring tested in presence of USCG inspector. all sat
Electrical › Lighting (service) › Lighting Fixture
Issued 28 May 2014
Resolved
Test/Repair/Replace all electrical fixtures to include Galley, Bar Storage Area, Passenger Heads, Exterior Lights. 46 CFR 183.10-20(L)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Tested newly installed lights in gallery, head, and bar area.
Electrical › Lighting (service) › Outlet Box
Issued 28 May 2014
Resolved
Test/Repair/Replace all electrical sockets for shock hazard. 46 CFR 183.01-10, 46 CFR 183.05-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: All electrical sockets tested for shock hazard.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 28 May 2014
Resolved
Repair/Replace rubber grommet used on shore tie connection. 46 CFR 183.10-50, 46 CFR 183.10-20(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Electrical grommet installed correctly.
Electrical › Lighting (service) › Outlet Box
Issued 28 May 2014
Resolved
2nd deck, Electrical junction box on stern under lifejackets checked for shock hazard. 46 CFR 183.01-10, 46 CFR 183.05-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Electrical junction box cleared for having a shock hazard.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 May 2014
Resolved
2nd deck, Remove dead end electrical cable in lifejacket storage aft. 46 CFR 183.01-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Dead end wire removed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 May 2014
Resolved
Repair/Replace starboard navigation light. 33 CFR Part 84
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Navigation light repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2014
Resolved
Remove all dead end wire from switchboard. 46 CFR 183.01-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: All dead end wires removed, holes in switchboard filled in.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 May 2014
Resolved
Label all emergency lighting. 46 CFR 184.30-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Emergency lighting labelled in engine room and bridge at missing locations.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 28 May 2014
Resolved
Verify proper ground detection on main switchboard. 46 CFR 111.35-15(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: Ground detection will be completed with new switchboard installation.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 May 2014
Resolved
Post EAP information. 46 CFR 16.401
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: EAP information posted as required.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 May 2014
Resolved
Re-locate COI frames to be visible for passengers. 46 CFR 176.01-40
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: New COI frame mounted on starboard bulkhead, 2nd deck.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 May 2014
Resolved
Update station bill. 46 CFR 185.514
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Station Bill posted in pilothouse.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 May 2014
Resolved
Post Emergency Broadcast Information. 46 CFR 184.506
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Posted in Pilothouse.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 May 2014
Resolved
Acquire FCC license. 46 CFR 184.25-1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: New FCC license onboard, COI reflects new call sign.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 May 2014
Resolved
Add bilge alarms to flying bridge. 46 CFR 182.530
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 16 March 2016
Resolution: Removed requirement added special note to vessel.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 May 2014
Resolved
Radio (on flying bridge) as required on bridge. 46 CFR 184.25-1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 16 March 2016
Resolution: Removed requirement added special note to vessel.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 28 May 2014
Resolved
Emergency Procedures Posted (flying bridge). 46 CFR 185.25-1(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 16 March 2016
Resolution: Removed requirement added special note to vessel.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 May 2014
Resolved
Post Emergency Broadcast Information, (flying bridge). 46 CFR 184.506
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 16 March 2016
Resolution: Removed requirement added special note to vessel.
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 May 2014
Resolved
Repair/Replace compass on flying bridge. 46 CFR 184.20-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 16 March 2016
Resolution: Removed requirement added special note to vessel.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 28 May 2014
Resolved
2nd deck aft starboard gate (on railing) does not lock closed. 46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Repaired and tested by USCG inspector.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 28 May 2014
Resolved
Main deck starboard side bow access door hinge is loose. 46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Repaired and tested by USCG inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 May 2014
Resolved
Repair/Replace galley door. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Repaired and tested by USCG inspector.
Construction/Loadline › Structures › Scuttle
Issued 28 May 2014
Resolved
Label & test (prove proper operation) of emergency escape hatch. 46 CFR 177.15-1, 46 CFR 185.30-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Tested emergency escape hatch and new ladder installed.
Construction/Loadline › Structures › Scuttle
Issued 28 May 2014
Resolved
Create design solution to forward escape hatch ladder. 46 CFR 177.15-1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: New step and ladder installed allowing the proper use of escape hatch. This ladder replaces a bed that used to be in the space but was found removed.
Engineering › Fuel Oil Service System › Valve
Issued 28 May 2014
Resolved
Label fuel shut off valves. 46 CFR 182.20-40(b)(3), 46 CFR 185.30-20(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Proper labelling installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 May 2014
Resolved
Fill holes to ensure watertight bulkhead in lazarette. 46 CFR 171.114 (old S)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Three holes in overhead of lazarette aluminum welded under starboard side seating area.
Stability › Watertight Integrity › General
Issued 28 May 2014
Resolved
Adjust watertight door aft in engine room. (verify alarm) 46 CFR 170.270
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Watertight door adjusted, tested and indicating lights on bridge tested. all sat
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 May 2014
Resolved
Close all slots on electrical panels. 46 CFR 183.10-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Slots on electrical panels closed with plastic covers.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 May 2014
Resolved
Label all breakers on electrical panels. 46 CFR 183.10-15
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Panels tested and verified, new listing of breaker locations mounted inside breaker box.
Engineering › Fuel Oil Service System › Hose
Issued 28 May 2014
Resolved
Verify fuel lines meet J-1942 standard. 46 CFR 182.20-40(a)(2)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: Documentation provided.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 28 May 2014
Resolved
Repair/Replace bow water pump bracket on port main. 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: New bracket supports water pump.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 May 2014
Resolved
Repair raw water hose on coupling on port main. 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: Raw water piping replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2014
Resolved
Repair/Replace damaged/cracked/frayed wiring on port main. 46 CFR 183.10-20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: Wiring replaced and all wiring on engine covered in vinyl protective loom.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 28 May 2014
Resolved
Repair all exhaust leaks. 46 CFR 182.20-20, 46 CFR 182.15-20(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: All exhaust leaks welded with new lagging in place.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 28 May 2014
Resolved
Replace exhaust insulation. 46 CFR 182.20-20, 46 CFR 182.15-20(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 4 August 2014
Resolution: New exhaust insulation on Port and Starboard Engines.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 28 May 2014
Resolved
Remove former name of vessel on port side. 46 CFR 67.123
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: Removed and verified.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 May 2014
Resolved
Verify all navigation lights (on upper mast) work as designed. 33 CFR Part 84
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 June 2014
Resolution: All lights work as designed.
Engineering › Fuel Oil Service System › Gauge
Issued 28 May 2014
Resolved
Verify pressure/vacuum gauge setup on Raycor Fuel Filters. 46 CFR 182.20-40(b)(5)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 7 July 2014
Resolution: Raycor fuel system has two vacuum gauges that indicate clogging filters. Gauges tested by partially closing filters valves.
Stability › Incline Test › General
Issued 2 May 2014
Resolved
Provide documentation on weights added and weights removed associated with replacement of ships service generators.
Action required: 705 - Other - as specified
Due 1 March 2015
Resolved 13 April 2015
Resolution: Incline experiment completed.
Electrical › Electric Generation Source (service) › Generator
Issued 2 May 2014
Resolved
Provide revised electrical plans for review and approval updating installation of new ships service generators
Action required: 705 - Other - as specified
Due 1 March 2015
Resolved 27 April 2015
Resolution: Installation and testing of new generators completed to approved plans from MSC.
Deck/Cargo › Cargo Stowage › General
Issued 30 July 2009
Resolved
Secure CO2 bottle under aft bar on 2nd deck (soda dispenser).
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Engineering › Thrusters › Seal
Issued 30 July 2009
Resolved
Make proper repairs to bow thruster hydraulic leak in bow thruster compartment.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Engineering › Thrusters › Seal
Issued 30 July 2009
Resolved
Identify where standing oil is coming from in aft stateroom (lower deck) midships.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Lifesaving › Lifebuoys › Serviceable
Issued 30 July 2009
Resolved
Provide retro tape on both port and starboard ring buoys on main deck fwd.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 21 July 2010
Stability › Watertight Integrity › General
Issued 30 July 2009
Resolved
Repair/replace gasket material on FWD compartment and emergency escape hatch from fwd lower stateroom (chef's stateroom).
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Communications › Visual Communication › Warning Sign (gangway)
Issued 30 July 2009
Resolved
Label "Emergency Exit, Keep Clear" in 2" letters on escape hatch main deck from Eng Room and hatch main deck from Chef's stateroom.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 21 July 2010
Stability › Severe Wind/Roll › General
Issued 30 July 2009
Resolved
Provide chain or other substantial strength device for hatches on bow (1st compartment and hatch to chef's stateroom) to prevent loss of hatch.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Engineering › Compressed Air System (start air) › Bursting Disc
Issued 30 July 2009
Resolved
Provide , to the satisfaction of attending Marine Inspector, that the relief valves on the air receivers activate at or below 200psi.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Resolution: 200 psi relief valves replaced with 150 psi tested port and stbd sat.
Fire Fighting › Ventilation Systems › Fans
Issued 30 July 2009
Resolved
Show proper operation of power ventilation exhaust to attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 July 2009
Resolved
Provide Alco or other approved alcohol teat kits onboard.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 12 August 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 May 2008
Resolved
Provide servicing report for all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2008
Documentation › Certificates/Documents › FCC SSL
Issued 7 May 2008
Resolved
Provide FCC bridge to bridge radio station license.
Due 15 May 2008
Resolved 9 May 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 May 2008
Resolved
Separate and label storage for child lifejackets.
Due 15 May 2008
Resolved 9 May 2008
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2008
Resolved
Replace or remove 2 lifering buoys on bow.
Due 15 May 2008
Resolved 9 May 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2008
Resolved
Stern light is obstructed by flag and flag pole. Relocate stern light or remove obstruction.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2008
Resolved
Replace oxidized masthead light.
Due 15 May 2008
Resolved 9 May 2008
Engineering › Shafting/Propeller Arrangements › Strut
Issued 11 February 2008
Resolved
Provide repair proposal for area of port and starboard struts.
Action required: 705 - Other - as specified
Resolved 3 March 2008
Construction/Loadline › Hull › Bottom Plating
Issued 11 February 2008
Resolved
Provide repair proposal for area of skeg.
Action required: 705 - Other - as specified
Resolved 3 March 2008
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 11 February 2008
Resolved
Make both air receivers in engine room available for inspection of the cylinder internals.
Action required: 705 - Other - as specified
Resolved 3 March 2008
Construction/Loadline › Hull › Side Shell
Issued 11 February 2008
Resolved
Provide repair proposal for starboard overboard discharges.
Action required: 705 - Other - as specified
Resolved 3 March 2008
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 11 February 2008
Resolved
Renew starboard shaft register.
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 3 March 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2007
Resolved
Provide current Bridge to Bridge Certificate.
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 2 May 2007
Resolution: fax
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 25 April 2007
Resolved
Remove Flammables from vessel.
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 25 April 2007
Resolution: Corrected on the spot.
Communications › Public Address System › Broadcast Location
Issued 25 April 2007
Resolved
Provide public address system in Crew's cabin area and galley as per 46 CFR 184.610 (b).
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 27 April 2007
Resolution: fax
Communications › Alarms/Indicators › Fire Alarm
Issued 25 April 2007
Resolved
Provide adequate smoke detection in crew accommodation spaces as required by 46 CFR 177.700 and 46 CFR 181.450.
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 27 April 2007
Resolution: fax
Construction/Loadline › Structures › Scuttle
Issued 25 April 2007
Resolved
Prove proper operation of escape hatch in forward berthing compartment.
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 27 April 2007
Resolution: fax
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 25 April 2007
Resolved
Provide/install Sea rails and latches on galley broiler, range top, and ovens IAW 46 CFR 184.220. Prior to using the galley underway.
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 27 April 2007
Resolution: fax
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 25 April 2007
Resolved
Relocate portable fire extinguishers on vessel and provide two additional AII extinguishers to provide adequate coverage of accommodation spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 27 April 2007
Resolution: fax
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 25 April 2007
Resolved
Provide corrected Station Bill to reflect only members of the crew enrolled in the drug testing program are engaged in Safety Sensitive Positions or provide evidence that all members assigned to the Station Bill have been enrolled and completed Pre-employment testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 27 April 2007
Resolution: fax
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 April 2007
Resolved
Vessel's type III sewage discharge valve was unsecured and in the open position while vessel was moored in the Inter coastal waterway of the Atlantic ocean.
Action required: 705 - Other - as specified
Due 25 April 2007
Resolved 25 April 2007
Resolution: Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 April 2007
Resolved
Vessel's engineering log on 10 January indicates that the Type III sewage holding tank was pumped overboard off Port Everglades inlet. Vessel's Type III sewage holding tank overboard discharge valve was unsecured and in the open condition within 3 miles of shore.
Action required: 705 - Other - as specified
Due 25 April 2007
Resolved 25 April 2007
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Hull Plating
Issued 29 January 2007
Resolved
Make permenet repairs to damage at port starboard bow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2007
Resolved 2 February 2007
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 29 January 2007
Resolved
Repair/replace damaged starboard propeller. Provide report of condition of port propeller.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2007
Resolved 2 February 2007
Engineering › Thrusters › Hose
Issued 17 July 2006
Resolved
Hydraulic Line on Bow Thruster, leaking fluid.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Electrical › Electric Generation Source (service) › Conductor
Issued 17 July 2006
Resolved
Rudder Angle indicator Electrical Cable insulation worn down to dare wire.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Engineering › Pressure Vessel › Relief Valve
Issued 17 July 2006
Resolved
Automatic Relief Valve is in-line with Manual Hand Valve, which allows auto valve to be by-passed.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 17 July 2006
Resolved
Water leak on Toilet piping in master state room.
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 27 July 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 17 July 2006
Resolved
Metal valves must be installed at Water tight bulkhead through penetrations prior to connecting to PVC piping.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Stability › Unintentional Flooding › General
Issued 17 July 2006
Resolved
Remove water from Transducer Coffer Dam space. Source of leak has been corrected.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Construction/Loadline › Penetrations › Weld
Issued 17 July 2006
Resolved
Provide proper welds on water tight Bulkhead through Penetrations in Master [name withheld] and Engine Room.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 17 July 2006
Resolved
Provide proper Electrical covers for A/C Air Handlers for VSL State Rooms.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Construction/Loadline › Hull › Side Shell
Issued 17 July 2006
Resolved
Replace plastic through Hull fittings with metal of equal (aluminum) hull strength and Shut-off valves.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Engineering › Fuel Oil Service System › Valve
Issued 17 July 2006
Resolved
Leaking fuel valves forward and after of the stbd generator and at the bilge Manifold.
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 27 July 2006
Construction/Loadline › Penetrations › Weld
Issued 17 July 2006
Resolved
Complete welding of piping Penetrations in Engine Room at AFT Bulkhead by work Bench.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 17 July 2006
Resolved
Double Clamp flexible hoses on Fire pump piping in Engine Room.
Action required: 705 - Other - as specified
Due 17 August 2006
Resolved 27 July 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 July 2006
Resolved
Prepare Potable Water tanks for visual inspection.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 21 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 17 July 2006
Resolved
Take Ultrasonic shots of the Hull Plating in specified areas, make ready for inspection.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 27 July 2006
Engineering › Bilge Water Management System › Eductor
Issued 17 July 2006
Resolved
Satisfactorily test all Bilge Suctions.
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 20 July 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 June 2006
Resolved
Provide tide and current information.
Due 12 July 2006
Resolved 10 July 2006
Lifesaving › Hand Flares › Expired
Issued 12 June 2006
Resolved
Re-new red hand flares no later than August 06.
Due 6 August 2006
Resolved 10 July 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 June 2006
Resolved
Make permenet repairs to pipe hole at bulkhead at frame 25 by next drydock.
Due 31 July 2006
Resolved 17 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2006
Resolved
Provide metal support starps every 24 " for electrical cabels in overhead.
Due 12 July 2006
Resolved 10 July 2006
Construction/Loadline › Hull › Transverse Frame
Issued 12 June 2006
Resolved
Replace plastic pipe penetrations at watertight bulkheads with metal pipes no later than next drydock.
Due 31 July 2006
Resolved 17 July 2006
Construction/Loadline › Structures › Superstructure
Issued 12 June 2006
Resolved
Re-new broken window at starboard bow no later than next drydock.
Due 31 July 2006
Resolved 17 July 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 June 2006
Resolved
Provide non-combutible waste receptacle through out vessel per 46 CFR 177.405 (F).
Due 12 July 2006
Resolved 10 July 2006
Electrical › Electric Generation Source (service) › Generator Cable
Issued 12 June 2006
Resolved
Provide proper supports ffor electrical wires on starboard genset.
Due 12 July 2006
Resolved 10 July 2006
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 2 August 2005
Resolved
Schedule a CG D7 DAPI Audit with [name withheld].
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 August 2005
Resolved
Provide current CG Light list and Coast Pilot onboard.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Documentation › Certificates/Documents › FCC SSL
Issued 2 August 2005
Resolved
Provide proof of FCC Safety Certificate and Marine Operators Permit.
Action required: 705 - Other - as specified
Due 5 November 2005
Resolved 12 June 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 August 2005
Resolved
Perform maintenance on all PFD's and replace failed retro reflective material.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 August 2005
Resolved
Provide proper ring life buoy lanyard IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 August 2005
Resolved
Prove proper operation of Compass light.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Fire Fighting › Fire Hoses › Condition
Issued 2 August 2005
Resolved
Renew 01 1.5" Fire hose due to leaky coupling.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 August 2005
Resolved
Remove extension cords and provide appropriate outlets for freezers in lazarette and refrigerator compressor.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 August 2005
Resolved
Provide means of securing embarkation gate while vessel is underway.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 2 August 2005
Resolved
Renew starboard shaft packing due to excessive leaking and all adjustment has been taken up.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Engineering › Compressed Air System (control) › Valve
Issued 2 August 2005
Resolved
Prove operation of, or replace pressure vessel relief valves IAW 46 CFR 176.25-32.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Electrical › Electric Generation Source (service) › Generator
Issued 2 August 2005
Resolved
Provide proof of proper installation of starboard ship service generator IAW 46 CFR 183.10-5 f (2). Recently installed generator is rated @ 70kw 40c. Original generator is rated @ 80kw 50c.
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Construction/Loadline › Hull › Strut/Cross Tie
Issued 20 July 2004
Resolved
Starboard strut cutlass bearing appears to be worn on the top size, aft. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector to receive credit for dry docking.
Condition: Unknown
Due 31 July 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Construction/Loadline › Hull › Hull Plating
Issued 20 July 2004
Resolved
Gouge in hull plate in bow thruster room. Grind out and properly weld each area allowing complete cooling between repairs. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector to receive credit for dry docking.
Due 31 July 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Engineering › Bilge Water Management System › Interface Detector
Issued 20 July 2004
Resolved
Bilge alarm not properly mounted. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to August 01, 2003.
Condition: Improper Installation
Due 27 July 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Electrical › Electrical Distribution System (service) › Cable
Issued 20 July 2004
Resolved
Remove or properly terminate dead end wire in bow thruster room Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to August 01, 2003.
Due 1 August 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Construction/Loadline › Penetrations › Valve Flange
Issued 20 July 2004
Resolved
Label location of A/C Through Hull Fitting and make availed for next dry-docking. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to August 01, 2003.
Due 1 August 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Construction/Loadline › Penetrations › Valve Flange
Issued 20 July 2004
Resolved
Replace fire pump and sewage through hull valve in forward engine room. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector to receive credit for dry docking.
Due 31 July 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Electrical › Electrical Distribution System (service) › Cable
Issued 20 July 2004
Resolved
Cable chaffing in several areas on bother generators. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector prior to August 01, 2003
Due 1 August 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 20 July 2004
Resolved
Provide proper anchor chaff chain and line and demonstrate use of ground tackle. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector to receive credit for dry docking
Due 31 July 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Construction/Loadline › Penetrations › Valve Flange
Issued 20 July 2004
Resolved
Replace through hull valve for washing machine with a metallic valve.
Due 1 August 2004
Resolved 27 July 2004
Resolution: Cleared by letter and pictures. CHK
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2004
Resolved
Replace deteriorated lifeline on lifering
Due 1 June 2004
Resolved 29 May 2004
Operations/Management › Log/Records
Issued 19 May 2004
Resolved
Provide training log with required entries LEGACY COMPONENT DESC: Training Log
Due 1 June 2004
Resolved 19 May 2004
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 19 May 2004
Resolved
Provide additional signage to more clearly indicate escape route from below main deck state rooms
Due 1 June 2004
Resolved 1 June 2004
Communications › Radio Communications
Issued 19 May 2004
Resolved
Provide cut-out for PA system from vessels entertainment system
Due 1 June 2004
Resolved 4 June 2004
Construction/Loadline › Penetrations › Weld
Issued 19 May 2004
Resolved
Locate source of salt water in master stateroom bilge
Due 4 June 2004
Resolved 5 October 2005
Fire Fighting
Issued 4 May 2000
Resolved
REPAIR/REPLACE FIRE PUMP TO PROVIDE 60 PSI AT 50 GPM DISCHARGE.
Condition: Unknown
Due 4 June 2000
Resolved 23 July 2002
Construction/Loadline
Issued 5 May 1999
Resolved
REMOVE ALL "PVC" PIPING FROM BILGE AND FIRE SYSTEM. REPLACE PIPE WITH A METALIC MATERIAL AND VALVES WITH A SHIPS MATERIAL.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Lifesaving
Issued 6 May 1996
Resolved
Replace all life rings with approved type.
Condition: Unknown
Due 13 May 1996
Resolved 20 May 1996
Lifesaving
Issued 6 May 1996
Resolved
Schedule a date with our office to conduct underway drills
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Unknown
Issued 6 May 1996
Resolved
Comply with drug testing program.
Condition: Unknown
Due 13 May 1996
Resolved 20 May 1996
Fire Fighting
Issued 6 May 1996
Resolved
Correct firepump pressure to 60# or greater.
Condition: Unknown
Due 6 June 1996
Resolved 3 June 1996
Fire Fighting
Issued 3 May 1993
Resolved
REPLACE FIRE PUMP PRESSURE GAUGE AND RETEST PUMP_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1993
Resolved 12 May 1993
Accommodation/Occupational Safety
Issued 3 May 1993
Resolved
PROVIDE HANDRAIL FOR STAIRWAY FROM MN DK TO 2ND DK AFT
Condition: Unknown
Due 3 June 1993
Resolved 12 May 1993
Accommodation/Occupational Safety
Issued 22 May 1992
Resolved
PROVIDE UNIMPEDED ACCESS TO EMERGENCY ESCAPE HATCH FROM MASTER SUITE AND MARK LOCATION OUTER CORRIDOR MARK HATCH ON MAIN DECK WITH "EMERGENCY EXIT- DO NOT BLOCK".
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Documentation
Issued 13 June 1989
Resolved
PROVIDE VALID FCC OPERATORS LICENSE.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Electrical
Issued 13 June 1989
Resolved
PROVE OPERATION OF GENERATORS.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Navigation
Issued 13 June 1989
Resolved
PROVE OPERATION OF STEERING SYSTEM.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 13 June 1989
Resolved
PROVE OPERATION OF PILOT HOUSE CONTROL.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 13 June 1989
Resolved
CONDUCT TEST OF PRESSURE RELIEF VALVES ON AIR RECEIVERS.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
PROVIDE WOODEN SPACERS BETWEEN LIFEFLOATS.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
GROUP LIFEFLOATS INDIVIDUALLY TO SINGLE PAINTER.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Fire Fighting
Issued 13 June 1989
Resolved
PROVE OPERATION OF FIRE PUMP TO 60 PSI.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 13 June 1989
Resolved
PROVE OPERATION OF PROPULSION SYSTEM.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 10 June 1988
Resolved
PLACE CG STAMP ON NAME PLATES OF BOTH AIR RECEIVERS AFTER SIGHTING MANUFACTURERS DATA SHEETS.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Fire Fighting
Issued 10 June 1988
Resolved
INSTALL FIXED CO2 SYSTEM OF THE APPROPRIATE SIZE IN THE GALLEY VENT HOOD.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Documentation
Issued 10 June 1988
Resolved
OBTAIN A COMPLETE STABILITY LETTER FROM MSC PRIOR TO CERTIFICATION.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988