MAURY USCG vessel records
← All vessels

CHICAGO ELITE

Built
1988
Last inspected
15 July 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5241
306009
Flag
UNITED STATES
Maury page id
psix-306009

Documentation record

Registered dimensions (L × B × D)115.2 ft × 27.0 ft × 7.6 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMINUM BOATS INC · JEAN LAFITTE, LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
107 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WINDY Passenger (Inspected) · MISLE 422442 · 29 June 2019 · activity 6743704

Inspection history · 29

15 July 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8439126
29 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8416739
20 March 2026 Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8330268
25 August 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8217784
6 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8129084
9 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7914033
3 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7905901
20 March 2024 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7882565
6 June 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7706494
2 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7685086
27 April 2023 Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7675935
26 August 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7544076
25 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7515842
3 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405350
16 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288066
10 June 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221189
8 April 2021 Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7170618
23 September 2020 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7063806
16 April 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6939963
19 March 2020 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6929216
10 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6808087
29 June 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743704
24 April 2019 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6669762
21 May 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6420463
25 April 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6399433
28 March 2017 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112766
30 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112770
16 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5834832
21 January 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5804384

Deficiency record · 28

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2026 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Fire extinguishers throughout vessel do not have brackets required for CG approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2026
Resolved 21 August 2026
Resolution: Brackets replaced with approved type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 June 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Air pressure gauges for throttles at bridge wings are unreadable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2026
Resolved 15 July 2026
Resolution: Air gauges replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 20 March 2026 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] pipe in port fwd engine compartment for bridal suite/ lower galley has a pinhole leak. Make permanent repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. There is a cracked electrical outlet located on the top deck aft starboard side. Replace cracked outlet. CFR 183.01-15(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2025
Resolved 25 August 2025
Resolution: Electrical outlet has been replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2024 Resolved
Aft swim platform railing system is missing hardware throughout and is pulling away from vessel structure. Replace/install all missing railing hardware. Main deck aft STBD side embarking gate top railing is loose. Make repairs/tighten. 46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 9 May 2024
Resolution: Aft swim platform railing system and emarkation gate top railing have been restored properly.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 April 2023 Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. Vessel could not provide satisfactory evidence of required monthly service. Conduct monthly servicing of all portable extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew completed monthly service while in attendance.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 April 2023 Resolved
Electrical outlets found with open ground circuits. 5 in the bridle suite, 1 GFI in the 1st deck starboard head and 1 with an open neatral circuit at the workbench in the Engineroom. Properly wire all defective circuits.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: All effected outlets where removed and blanked off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2023 Resolved
Hoses on Both main engine R/W suction lines to the pump and the Bow Thruster PTO Actuator port main are deteriorated, renew all hoses.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: All hoses where renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 27 April 2023 Resolved
Hot water heaters (3) are wasted on the bottoms and the safety relief valves are not properly plumbed and could relieve in someone's face. Renew heaters and plumb IAW manufactures instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 6 June 2023
Resolution: Hot water heater was renewed and relief valve escape piping was properly routed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 27 April 2023 Resolved
Properly Label on both sides Escape hatch in Engineroom with 1 inch minimum letters "Escape Hatch Keep Clear" and all watertight doors "Watertight Door-Keep Closed"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2023
Resolution: sighted proper markings
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 April 2023 Resolved
Starboard aft loading gate is damagaged and does not latch. Repair Latch, gate must take load of 200lbs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: Gate was repaired by welding and gate latch was fabricated to lock.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2023 Resolved
Managers office was littered with empty cardboard boxes, several electrical outlets where missing covers and an extension cord was daisy chained into a UPS to provide power for a mini fridge. Remove fire hazards and repair electrical safety issues.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Ships crew removed all boxes, installed outlet covers, unhooked mini fridge and removed extension cords from space.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 July 2022 Resolved
The audible high level bilge alarms and the visual indicators for the two watertight doors at the flybridge operating station are inoperable. The vessel is restricted from the use of the flybridge operating station until all audible/visual alarms and indicators are operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 August 2022
Resolution: Inspector witnessed satisfactory operation of bilge high-level alarms and watertight door indicator lights on the flybridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2022 Resolved
The vessel's generators are capable of operating in parallel. 46 CFR 111.12(f) requires reverse power relays for each generator arranged for parallel operation. Prove proper operation of the reverse power relays and provide training for the crew on paralleling generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
Resolution: Witnessed satisfactory testing/operation of the reverese power relays for both port and starboard generators.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 July 2022 Resolved
Make repairs to copper piping leak directly above distribution panel in the steering space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2022 Resolved
Demonstrate that the electronic interlock will prevent parallel operation of the generators with shore power.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 29 August 2022
Resolution: Inspector witnessed satisfactory operation of electronic interlock preventing parallel operation of generators w/ shore power.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021 Resolved
Properly mark Life Jackets with vessel name and replace retro reflective tape on same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 16 August 2021
Resolution: All jackets have been marded iaw applicable CFR
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 April 2021 Resolved
During vessel drydock and internal exam, in the starboard stern and corner area of vessel, there is damage discovered. The following are approx. estimates and will require submitted repair proposal for approval by OCMI prior to beginning repair. Appox. 4' x 7' hull plate is bowed and inset, two corner gusset brackets are bent, side longs bent/distorted, and a section of vertical channel is crushed. In the approx. same area on the deck, there is a section of floor joist bar with a broken weld pick up. Vessel shall submit repair plan to local OCMI for approval, complete repairs, and conduct testing with local OCMI prior to conducting operations with passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 May 2021
Resolved 23 April 2021
Resolution: All repairs, pick ups, and testing completed. DD/ISE credit issued.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 May 2019 Resolved
Repair/replace insulation in engine room overhead by stairs to satisfaction of attending Marine Inspector. 46CFR177.10-5 "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 10 September 2019
Resolution: Received photos of new insulation install
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2019 Resolved
Remove flameable presurized cans from engine room space to satisfaction of attending Marine Inspector. 46CFR176.25-50(a) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Flameable presurized cans were removed from engine room space to the satisfaction of attending Marine Inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 May 2019 Resolved
Repair/replace port engine exhaust lagging over flanged area to satisfaction of attending Marine Inspector. 46CFR182.20-20(a) 46CFR182.15-20(g) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2019
Resolved 10 September 2019
Resolution: Lagging has been fixed, added to exhaust flang
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2019 Resolved
Label breaker for shore power to satisfaction of attending Marine Inspector. 46CFR183.10-20(i) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Shore power breaker was labeled to satisfaction of attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 May 2019 Resolved
Repair/replace WTD between lazarette and engine room to satisfaction of attending Marine Inspector. 46CFR176.25-5(a)(2) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Quick acting WTD assembly was tighted and chalk tested to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2019 Resolved
Repair/replace grab line on two (2) life ring buoys to the satisfaction of attending Marine Inpector. 46CFR180.30 "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Grab lines on the two (2) life ring buoys were repaired/replaced to the satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 May 2019 Resolved
Remove oil under starboard generator to the satisfaction of attending Marine Inspector. 46CFR176.25-50(b) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 May 2019
Resolved 3 May 2019
Resolution: Oil was removed from underneith starboard generator to the satisfaction of attending Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 April 2018 Resolved
Provide buoyant lifeline 60 feet 5/16".
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 21 May 2018
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 25 April 2018 Resolved
Hydro test air receivers to 1.5 MAWP or make available for internal exam.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 21 May 2018
Electrical › Electric Generation Source (service) › Conductor
Issued 25 April 2018 Resolved
Properly support electrical cables throughout vessel 24" on center.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2018
Resolved 21 May 2018

Recorded names · 1

KATHLEEN WINDRIDGE (2007–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.