WINDY

WINDY is a 1996 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 2016, most recently in June 2026, along with 40 deficiencies, 3 operational controls and 5 casualty investigations between 2011 and 2021.

Records from 2011 to 2026. Most recent: inspection, 9 June 2026.

Built
1996
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF9441
422442
Flag
UNITED STATES
Maury page id
psix-422442

Inspections, by type

…with no type recorded3
Years with a record 11 calendar years (2016–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)94.9 ft × 24.8 ft × 16.8 ft
Registered tonnagegross 75 / net 66
ITC dimensions (L × B × D)94.9 ft × 24.8 ft × 16.8 ft
ITC tonnagegross 188 / net 66
BuilderDETYENS SHIPYARD · MT PLEASANT, SC, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 9 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it188 - Convention (Subpart B), Gross Ton
75 - Regulatory (Subpart C or D), Gross Ton
66 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHICAGO ELITE Passenger (Inspected) · MISLE 306009 · 29 June 2019 · activity 6743704

Inspection history · 44

9 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8395522
27 August 2025 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8218981
8 July 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8179067
1 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8172083
23 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8142116
10 July 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7954837
13 June 2024 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7933912
11 July 2023 Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7759415
16 May 2023 COI Inspection · Deficiency Check · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7689947
17 April 2023 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7670886
29 November 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7601135
28 September 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7567711
15 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7559424
19 August 2022 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7540890
20 July 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7511605
6 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425706
10 August 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7283410
6 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7283402
26 July 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7269390
31 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7211793
30 May 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7212017
3 June 2020 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6967097
25 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6829756
16 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6813255
12 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6810223
9 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6807254
14 August 2019 Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6783318
26 July 2019 Attraction Vessel Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6763124
18 July 2019 Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6760693
29 June 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6733917
29 June 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743704
26 June 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6729493
26 June 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743181
3 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6703060
10 January 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6608324
16 May 2018 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6416581
16 April 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6393411
27 March 2018 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6379655
4 October 2017 Drydock Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6281371
11 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6206306
5 June 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6167062
28 July 2016 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5960174
29 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5923323
3 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5808640

Deficiency record · 40

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2025 Resolved
The bilge pipe suctions shall be fitted with suitable strainers. The strainer and pipe in the main hull void space are corroded, fractured, and broken. Repair or replace piping section and suction strainer. 46 CFR 182.510(b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 8 July 2025
Resolution: Received photographic evidence of repair to bilge suction strainer.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 July 2024
Resolution: POC provided proof of negative pre-employment test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
Each EAP program must contain display and distribution of community service hot line phone number for crew assistance. The new hotline numbers are not posted. Post the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of posted EAP information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
A EAP training program must be conducted for crew members and supervisory personnel. Complete EAP training which includes all elements in 46 CFR 16.401(b) and document the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of signed drug and alcohol and EAP training sheets for each crewmember.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2024 Resolved
All electrical installations shall be to the satisfation of the Officer in Charge, Marine Inspection. The bar area has surge protectors daisy chained to others. Remove daisy chained surge protectors or plug directly into provided outlets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided e-mail stating the electrical cords have been removed and the UPS plugged directly in to an existing outlet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2024 Resolved
Flexible or portable cords and similar types cannot be used for permanently installed wiring. There is a white extension cord permanently installed above the cabinets in the galley area service window. Remove extension cord.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
Resolution: Extension cord was removed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 June 2024 Resolved
Each disposable hydrostatic release unit must be marked with the expiration date of two years after the date on which the unit was installed. EPIRB hydrostatic release is not properly marked with the expiration date. Replace the hydrostatic release and record proper expiration date.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of installed hydrostatic release with expiration date of June 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2024 Resolved
The float free link for the lifefloats must be of a proper size and strength as indicted by the identification tag. The identification tag for two lifefloat links are missing. Replace the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of replaced weak links for life floats.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2024 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non-watertight enclosure. The high water alarm in the lazarette operates intermittently. Repair or replace the alarm.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided e-mail stating that the high water alarm was found with a loose electrical connection and is "100% operational".
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
Provide written plan for compliance with the master key control requirements outlined in CVC Policy Letter 23-06.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided e-mail detailing Master [name withheld] plan for the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 May 2023 Resolved
VESSEL FWD ESCAPE HATCH IN FRONT OF MASTER BERTHING NEEDS TO BE LABELED ON TOP DECK SIDE OF HATCH. "ESCAPE EXIT, KEEP CLEAR"" AT LEAST 2" HIGH LETTERS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 3 June 2023
Resolution: Emergency exit has been properly labeled.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2023 Resolved
VESSEL EPIRB BATTERY IS EXPIRED. ENSURE EPIRB BATTERY IS CURRENT AND ON VESSEL READY FOR AUTO RELEASE. VESSEL IS RESTRICTED IN ROUTE TO NO MORE THAN 1 NM FROM SHORE AND BE WITHIN THE AREA SOUTH OF THE NORTH AVE JETTY LIGHT AND NORTH OF THE ADLER PLANETARIUM DURING COLD WATER PERIOD OF 01 OCT TO 14 JUN.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 19 May 2023
Resolution: Vessel EPIRB battery replaced. Vessel route authorized as per valid COI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2023 Resolved
POWER STRIPS IN THE GALLEY AREA NEED TO BE SESCURLY MOUNTED.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Crew secured power strips during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2022 Resolved
The vessel is scheduled to replace the main engine transmission in Sturgeon Bay, WI in April of 2023. During that service, the propellers haft should be drawn & the top end shaft coupling removed to inspect/measure the internal bore diameter & keyway for wear. Verify proper shaft & key fit within the coupling. Verify proper shaft alignment through the stern tube & proper engine to shaft alignment. Also verify the bolt used to replace the solid steel coupling retaining pin with the manufacturer to ensure it has the same shear strength as the original, solid steel, pin.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2023
Resolution: MSD Sturgeon Bay has cleared def, see case #7670886 for details.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 July 2022 Resolved
10 person and 8 person lifefloats are splitting and in need or replacement. On or before October 1, 2022 replace 10 and 8 person lifefloats with CG type approved float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2022
Resolved 29 November 2022
Resolution: 22 person purchased to replace 8 and 10 person.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2022 Resolved
Forward ring buoy was 20 inches. Replace 20 inch ring buoy with 24 inch ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2022
Resolved 19 August 2022
Resolution: Life ring was replaced with 24 inch type.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2022 Resolved
Replace temporary electrical installation for WI-FI extender and camera in forward crew passage with permanent installation(hard wire or acceptable outlet)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2022
Resolved 19 August 2022
Resolution: Permanent electrical installation was made to Inspector satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 July 2021 Resolved
Required paddles on lifefloats are cracked and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2021
Resolution: New Paddles where purchased and photo sent.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 July 2021 Resolved
Replace all damaged “SOLAS” reflective tape on lifefloats
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2021
Resolution: Photo of new solas tape on life floats provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 July 2021 Resolved
Passenger benches located on the main deck are cracked and sagging causing hazard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2021
Resolution: damaged boards on seating was renewed, photo provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 July 2021 Resolved
02 fire extinguishers were not serviced in may 2021. Provide proof that all extinguishers have been serviced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2021
Resolution: Extinguishers where serviced and tag validated during in service exam on 10AUG2021.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2021 Resolved
Miscellaneous cell phone chargers found in vessels galley. All chargers need to be “UL” approved.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2021
Resolution: Multiple chargers where removed and charging station was provided and stamped as ETL safety certified. MFG Atomi Charge Tower Pro model.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 July 2021 Resolved
PORT side under the passenger gangway, the water drainage scuppers were lashed closed. Vessel crew removed lashings on the spot
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 26 July 2021
Resolution: Removed lashings on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2020 Resolved
USCG approved first aid kit on board has expired items. Aspirn and eye wash are expired. Replace expired items to the satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 27 June 2020
Resolution: Items were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 June 2020 Resolved
Prove proper operation of all vessel freeing ports on the main deck. Port side free port has broken weld. Some free ports are lashed closed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 25 June 2020
Resolution: Freeing ports cut from their restrictions. Viewed photograph of repaired broken weld for freeing port on port side of main deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2019 Resolved
Vessel reported loss of propulsion while tying up to dock at Navy Pier. Provide dive plan prior to dive operations. Then submit dive report once inspection has been completed. Prior to departure, vessel must prove propulsion system (tailshaft) is fully operational to the satisfaction of the attending marine inspector. 46 CFR 182.200
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2019
Resolution: Tested engine forward and reverse several times with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2019 Resolved
While mooring up to dock, engine would not come out of gear and vessel colided with another P/V. Must make repairs and test to Satisfaction of CG Inspector prior carrying passengers. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 29 June 2019
Resolution: Added lock washers and thread sealant to both bolts that clamp the throttle cable to reduction gear. Vessel underway and tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2019 Resolved
Vessel has made unapproved changes to and/or altered propulsion engine and general/charging electrical systems since last inspection. Return vessel electrical system to the Coast Guard stamped approved plans or submit vessel AC and DC electrical on line plans with the alterations to the Marine Safety Center for approval. The submittal requires Bill of Materials, Cable sizes, type and details including load analysis.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 14 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 June 2019 Resolved
Vessel has overhauled propulsion engine since last inspection. Prove alarm systems work for engine regarding high temperature and low lube oil pressure to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 14 August 2019
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 May 2018 Resolved
Install proper bracket on fuel remote shut off valve and prove proper operation per 46 cfr 182.455(a)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 16 May 2018
Resolution: Bracket was renewed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 May 2018 Resolved
Secure life float light to life float.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2018
Resolved 8 May 2018
Resolution: Corrected on the spot
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2018 Resolved
Vessel may only carry passengers for hire with [name withheld] serving as Captain until other Captain can complete successful drills per 46 CFR 185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 16 May 2018
Resolution: [name withheld] completed satisfactory MOB drills with crew.
Lifesaving › Lifefloat › Paddle
Issued 27 March 2018 Resolved
Replace split paddles on lifefloat(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2018
Resolved 9 May 2018
Sail Rigging › Running Rigging › Sheets
Issued 4 October 2017 Resolved
Prior to carrying passengers, make all rigging available for inspection and provide records of maintenance available for review. 46 CFR 176.802
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2018
Resolved 16 April 2018
Resolution: Conducted rigging inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017 Resolved
Renew all expired contents in the First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 June 2017 Resolved
Install double hose clamp on the main engine exhaust pipe elbow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 5 June 2017 Resolved
Remove stores from forward berths and return to berths. Excess weight, fireload etc. being stored in these areas.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 June 2017 Resolved
Remove excess oil from engineroom bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 5 June 2017 Resolved
Remove all plastic waste receptacles throughout vessel and replace with non combustible type (Metal)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Lifesaving › Lifefloat › Paddle
Issued 5 June 2017 Resolved
Renew life float oars with paddles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017

Casualty record · 5

4 June 2011Routine · role: Involved in a Marine Casualty · activity 4045336
24 August 2012Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 4569137
26 June 2019Routine · role: Involved in a Marine Casualty · activity 6743181
29 June 2019Routine · role: Involved in a Marine Casualty · activity 6743704
30 May 2021Routine · role: Involved in a Marine Casualty · activity 7212017
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.