MAURY USCG vessel records Sign in
← All vessels

WINDY

WINDY is a 1996 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1995, most recently in June 2026, along with 117 deficiencies, 4 operational controls and 5 casualty investigations between 2011 and 2021.

Records from 1995 to 2026. Most recent: inspection, 9 June 2026.

Built
1996
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF9441
422442
Flag
UNITED STATES
367505190
Maury page id
psix-422442

Inspections, by type

…with no type recorded9
Years with a record 30 calendar years (1995–2026)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)94.9 ft × 24.8 ft × 16.8 ft
Registered tonnagegross 75 / net 66
ITC dimensions (L × B × D)94.9 ft × 24.8 ft × 16.8 ft
ITC tonnagegross 188 / net 66
BuilderDETYENS SHIPYARD · MT PLEASANT, SC, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 9 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it188 - Convention (Subpart B), Gross Ton
75 - Regulatory (Subpart C or D), Gross Ton
66 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF9441MMSI 367505190 · active · compulsorily equipped · granted 8 July 2021, expires 28 September 2031
WCW4605MMSI 303620000 · expired · compulsorily equipped · granted 1 April 2006, cancelled 25 June 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHICAGO ELITE Passenger (Inspected) · MISLE 306009 · 29 June 2019 · activity 6743704

Inspection history · 88

9 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8395522
27 August 2025 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8218981
8 July 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8179067
1 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8172083
23 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8142116
10 July 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7954837
13 June 2024 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7933912
11 July 2023 Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7759415
16 May 2023 COI Inspection · Deficiency Check · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7689947
17 April 2023 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7670886
29 November 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7601135
28 September 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7567711
15 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7559424
19 August 2022 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7540890
20 July 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7511605
6 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425706
10 August 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7283410
6 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7283402
26 July 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7269390
31 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7211793
30 May 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7212017
3 June 2020 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6967097
25 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6829756
16 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6813255
12 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6810223
9 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6807254
14 August 2019 Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6783318
26 July 2019 Attraction Vessel Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6763124
18 July 2019 Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6760693
29 June 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6733917
29 June 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743704
26 June 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6729493
26 June 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6743181
3 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6703060
10 January 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6608324
16 May 2018 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6416581
16 April 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6393411
27 March 2018 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6379655
4 October 2017 Drydock Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6281371
11 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6206306
5 June 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6167062
28 July 2016 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5960174
29 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5923323
3 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5808640
16 September 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5720749
21 July 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5191049
4 August 2014 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4944600
2 June 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4880473
27 July 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4396089
25 June 2012 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4357398
28 September 2011 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4155598
24 September 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4153107
21 August 2011 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4123923
4 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3863535
16 July 2009 MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3536655
3 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3445413
1 October 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3331599
18 June 2008 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3233180
23 April 2008 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3188780
26 December 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3121109
18 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2946793
11 August 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2743869
3 August 2006 Attraction Vessel Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2739073
7 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2598634
23 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2590607
18 July 2005 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2430584
9 July 2004 Re-Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2123952
16 October 2002 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1690140
6 September 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1671717
3 July 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1635809
3 June 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1625724
5 July 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1422088
17 July 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1051936
30 April 2000 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1395432
27 April 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1048486
8 July 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1469912
6 May 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1126869
29 April 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 792417
9 July 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1451310
21 April 1998 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 792226
26 December 1997 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1372078
15 December 1997 Plan Review "T" Boat
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1115447
16 July 1997 Drydock Extension · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1424443
9 July 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 778422
23 April 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1098827
20 November 1996 Plan Review "T" Boat
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1181881
18 July 1996 Initial Certification · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1435810
28 June 1995 Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1390291

Deficiency record · 117

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2025 Resolved
The bilge pipe suctions shall be fitted with suitable strainers. The strainer and pipe in the main hull void space are corroded, fractured, and broken. Repair or replace piping section and suction strainer. 46 CFR 182.510(b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 8 July 2025
Resolution: Received photographic evidence of repair to bilge suction strainer.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 July 2024
Resolution: POC provided proof of negative pre-employment test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
Each EAP program must contain display and distribution of community service hot line phone number for crew assistance. The new hotline numbers are not posted. Post the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of posted EAP information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
A EAP training program must be conducted for crew members and supervisory personnel. Complete EAP training which includes all elements in 46 CFR 16.401(b) and document the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of signed drug and alcohol and EAP training sheets for each crewmember.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2024 Resolved
All electrical installations shall be to the satisfation of the Officer in Charge, Marine Inspection. The bar area has surge protectors daisy chained to others. Remove daisy chained surge protectors or plug directly into provided outlets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided e-mail stating the electrical cords have been removed and the UPS plugged directly in to an existing outlet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2024 Resolved
Flexible or portable cords and similar types cannot be used for permanently installed wiring. There is a white extension cord permanently installed above the cabinets in the galley area service window. Remove extension cord.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
Resolution: Extension cord was removed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 June 2024 Resolved
Each disposable hydrostatic release unit must be marked with the expiration date of two years after the date on which the unit was installed. EPIRB hydrostatic release is not properly marked with the expiration date. Replace the hydrostatic release and record proper expiration date.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of installed hydrostatic release with expiration date of June 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2024 Resolved
The float free link for the lifefloats must be of a proper size and strength as indicted by the identification tag. The identification tag for two lifefloat links are missing. Replace the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided picture of replaced weak links for life floats.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2024 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non-watertight enclosure. The high water alarm in the lazarette operates intermittently. Repair or replace the alarm.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided e-mail stating that the high water alarm was found with a loose electrical connection and is "100% operational".
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
Provide written plan for compliance with the master key control requirements outlined in CVC Policy Letter 23-06.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 10 July 2024
Resolution: POC provided e-mail detailing Master [name withheld] plan for the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 May 2023 Resolved
VESSEL FWD ESCAPE HATCH IN FRONT OF MASTER BERTHING NEEDS TO BE LABELED ON TOP DECK SIDE OF HATCH. "ESCAPE EXIT, KEEP CLEAR"" AT LEAST 2" HIGH LETTERS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 3 June 2023
Resolution: Emergency exit has been properly labeled.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2023 Resolved
VESSEL EPIRB BATTERY IS EXPIRED. ENSURE EPIRB BATTERY IS CURRENT AND ON VESSEL READY FOR AUTO RELEASE. VESSEL IS RESTRICTED IN ROUTE TO NO MORE THAN 1 NM FROM SHORE AND BE WITHIN THE AREA SOUTH OF THE NORTH AVE JETTY LIGHT AND NORTH OF THE ADLER PLANETARIUM DURING COLD WATER PERIOD OF 01 OCT TO 14 JUN.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 19 May 2023
Resolution: Vessel EPIRB battery replaced. Vessel route authorized as per valid COI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2023 Resolved
POWER STRIPS IN THE GALLEY AREA NEED TO BE SESCURLY MOUNTED.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Crew secured power strips during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2022 Resolved
The vessel is scheduled to replace the main engine transmission in Sturgeon Bay, WI in April of 2023. During that service, the propellers haft should be drawn & the top end shaft coupling removed to inspect/measure the internal bore diameter & keyway for wear. Verify proper shaft & key fit within the coupling. Verify proper shaft alignment through the stern tube & proper engine to shaft alignment. Also verify the bolt used to replace the solid steel coupling retaining pin with the manufacturer to ensure it has the same shear strength as the original, solid steel, pin.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2023
Resolution: MSD Sturgeon Bay has cleared def, see case #7670886 for details.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 July 2022 Resolved
10 person and 8 person lifefloats are splitting and in need or replacement. On or before October 1, 2022 replace 10 and 8 person lifefloats with CG type approved float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2022
Resolved 29 November 2022
Resolution: 22 person purchased to replace 8 and 10 person.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2022 Resolved
Forward ring buoy was 20 inches. Replace 20 inch ring buoy with 24 inch ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2022
Resolved 19 August 2022
Resolution: Life ring was replaced with 24 inch type.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2022 Resolved
Replace temporary electrical installation for WI-FI extender and camera in forward crew passage with permanent installation(hard wire or acceptable outlet)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2022
Resolved 19 August 2022
Resolution: Permanent electrical installation was made to Inspector satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 July 2021 Resolved
Required paddles on lifefloats are cracked and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2021
Resolution: New Paddles where purchased and photo sent.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 July 2021 Resolved
Replace all damaged “SOLAS” reflective tape on lifefloats
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2021
Resolution: Photo of new solas tape on life floats provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 July 2021 Resolved
Passenger benches located on the main deck are cracked and sagging causing hazard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2021
Resolution: damaged boards on seating was renewed, photo provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 July 2021 Resolved
02 fire extinguishers were not serviced in may 2021. Provide proof that all extinguishers have been serviced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2021
Resolution: Extinguishers where serviced and tag validated during in service exam on 10AUG2021.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2021 Resolved
Miscellaneous cell phone chargers found in vessels galley. All chargers need to be “UL” approved.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2021
Resolution: Multiple chargers where removed and charging station was provided and stamped as ETL safety certified. MFG Atomi Charge Tower Pro model.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 July 2021 Resolved
PORT side under the passenger gangway, the water drainage scuppers were lashed closed. Vessel crew removed lashings on the spot
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 26 July 2021
Resolution: Removed lashings on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2020 Resolved
USCG approved first aid kit on board has expired items. Aspirn and eye wash are expired. Replace expired items to the satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 27 June 2020
Resolution: Items were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 June 2020 Resolved
Prove proper operation of all vessel freeing ports on the main deck. Port side free port has broken weld. Some free ports are lashed closed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 25 June 2020
Resolution: Freeing ports cut from their restrictions. Viewed photograph of repaired broken weld for freeing port on port side of main deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2019 Resolved
Vessel reported loss of propulsion while tying up to dock at Navy Pier. Provide dive plan prior to dive operations. Then submit dive report once inspection has been completed. Prior to departure, vessel must prove propulsion system (tailshaft) is fully operational to the satisfaction of the attending marine inspector. 46 CFR 182.200
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2019
Resolution: Tested engine forward and reverse several times with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2019 Resolved
While mooring up to dock, engine would not come out of gear and vessel colided with another P/V. Must make repairs and test to Satisfaction of CG Inspector prior carrying passengers. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 29 June 2019
Resolution: Added lock washers and thread sealant to both bolts that clamp the throttle cable to reduction gear. Vessel underway and tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2019 Resolved
Vessel has made unapproved changes to and/or altered propulsion engine and general/charging electrical systems since last inspection. Return vessel electrical system to the Coast Guard stamped approved plans or submit vessel AC and DC electrical on line plans with the alterations to the Marine Safety Center for approval. The submittal requires Bill of Materials, Cable sizes, type and details including load analysis.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 14 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 June 2019 Resolved
Vessel has overhauled propulsion engine since last inspection. Prove alarm systems work for engine regarding high temperature and low lube oil pressure to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 14 August 2019
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 May 2018 Resolved
Install proper bracket on fuel remote shut off valve and prove proper operation per 46 cfr 182.455(a)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 16 May 2018
Resolution: Bracket was renewed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 May 2018 Resolved
Secure life float light to life float.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2018
Resolved 8 May 2018
Resolution: Corrected on the spot
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2018 Resolved
Vessel may only carry passengers for hire with [name withheld] serving as Captain until other Captain can complete successful drills per 46 CFR 185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 16 May 2018
Resolution: [name withheld] completed satisfactory MOB drills with crew.
Lifesaving › Lifefloat › Paddle
Issued 27 March 2018 Resolved
Replace split paddles on lifefloat(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2018
Resolved 9 May 2018
Sail Rigging › Running Rigging › Sheets
Issued 4 October 2017 Resolved
Prior to carrying passengers, make all rigging available for inspection and provide records of maintenance available for review. 46 CFR 176.802
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2018
Resolved 16 April 2018
Resolution: Conducted rigging inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017 Resolved
Renew all expired contents in the First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 June 2017 Resolved
Install double hose clamp on the main engine exhaust pipe elbow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 5 June 2017 Resolved
Remove stores from forward berths and return to berths. Excess weight, fireload etc. being stored in these areas.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 June 2017 Resolved
Remove excess oil from engineroom bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 5 June 2017 Resolved
Remove all plastic waste receptacles throughout vessel and replace with non combustible type (Metal)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Lifesaving › Lifefloat › Paddle
Issued 5 June 2017 Resolved
Renew life float oars with paddles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 11 July 2017
Lifesaving › Lifefloat › Float-free Link
Issued 3 June 2014 Resolved
Verify float free link is marked with required information. 46 CFR 160.073-20(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 19 November 2014
Resolution: [name withheld] verified float free link was marked with the required information.
Lifesaving › Lifefloat › Markings
Issued 3 June 2014 Resolved
Replace SOLAS reflective tape on lifefloats. 46 CFR 164.018, 46 CFR 160.10-4
Condition: Damaged By Earlier Event
Due 3 July 2014
Resolved 3 July 2014
Resolution: Verified new SOLAS tape was placed on life float as required.
Lifesaving › Lifefloat › Painter
Issued 25 June 2012 Resolved
Provide 100 ft painters, and weak links for both 8 person Lifefloats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 27 July 2012
Resolution: Verified new painters and weak links.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 June 2012 Resolved
Renew GFI recepticle in the female head.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 27 July 2012
Resolution: Replaced GFI outlet in female head.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 25 June 2012 Resolved
Renew all starter cables and 24VDC inverter cables with cables approved per 46 CFR 183.340(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 28 August 2012
Resolution: All starter cables and 24VDC inverter cables were changed out with approved cable as required in 46 CFR 183.340(d)
Engineering › Diesel Engine (auxiliary) › Governor
Issued 25 June 2012 Resolved
Renew Generator set governor return spring with correct spring per 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 23 August 2012
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 June 2012 Resolved
Provide onboard Coast Pilot, Corrected charts and Navigation rules per 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 27 July 2012
Resolution: Purchased new charts for the operational area of the vessel.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 June 2012 Resolved
Provide onboard Abandon Ship drills for all crew and document.
Due 27 July 2012
Resolved 27 July 2012
Resolution: Conducted and logged Abandon Ship Drills with crew.
Sail Rigging › Deck Hardware › Shackles
Issued 25 June 2012 Resolved
Submit rigging inventory and preventative maint. plan to OCMI per 46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2012
Resolved 22 January 2013
Resolution: Re-issued CG-835
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 June 2012 Resolved
Cover all battery terminals to prevent contact from falling objects per 46 CFR 183.354
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 27 July 2012
Resolution: Operator built battery cover over the required batteries.
Lifesaving › Lifejacket/PFD (Type V) › Marking
Issued 25 June 2012 Resolved
Provide onboard work PFD's meeting 46 CFR 180.72(c)
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 27 July 2012
Resolution: Purchased 2 new work vests
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 September 2011 Resolved
Provide annual report of all applicable fire fighting equipment.
Due 28 October 2011
Resolved 19 October 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 September 2011 Resolved
Install correct mounting brackets for portable fire extinguishers.
Condition: Invalid
Due 28 October 2011
Resolved 19 October 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 27 September 2011 Resolved
install proper electrical cable supports.
Condition: Improper Installation
Due 28 October 2011
Resolved 19 October 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 September 2011 Resolved
ring life bouy lights do not function properly.
Condition: Improper/Lack of Maintenance
Due 28 October 2011
Resolved 19 October 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 September 2011 Resolved
provide complete first aid kit replace expired medications.
Condition: Improper/Lack of Maintenance
Due 28 October 2011
Resolved 28 September 2011
Construction/Loadline › Structures › Superstructure
Issued 27 September 2011 Resolved
Provide annual rigging and associated gear report of inspection.
Due 28 October 2011
Resolved 20 October 2011
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 27 September 2011 Resolved
provide flame spread rating of carpet.
Due 28 October 2011
Resolved 19 October 2011
Resolution: Flame spread of a non wool product is met according to ASTM E648
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 24 September 2011 Resolved
Prove proper operation of transmission and shaft seal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 October 2010 Resolved
Both 8-man Lifefloats are missing the required Floating electric waterlight. Issued CG-835.
Due 31 March 2011
Resolved 15 April 2011
Resolution: Lights installed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 October 2010 Resolved
Vessel was missing smoke detectors in all berthing spaces.
Due 31 March 2011
Resolved 15 April 2011
Resolution: Smoke detectors installed in all berth areas.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 July 2009 Resolved
Circuit Breaker box in Captain's quarters was not properly labeled.
Action required: 705 - Other - as specified
Due 20 August 2009
Resolved 24 August 2009
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 July 2009 Resolved
Light bulb in fixture forward at the captains stateroom was burned out.
Action required: 705 - Other - as specified
Due 20 August 2009
Resolved 21 August 2009
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 July 2009 Resolved
Hydrostatic Release was expired on EPIRB
Action required: 705 - Other - as specified
Due 20 August 2009
Resolved 21 August 2009
Resolution: Issued new CG-835 restricting vessel''s route to less than 3 miles.
Construction/Loadline › Hull › Bottom Plating
Issued 18 June 2008 Resolved
Make hull below main salon available for inspection iaw 46 CFR 176.600.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: Area below main salon inspected.
Documentation › Markings/Placards › Warning Signs
Issued 18 June 2008 Resolved
Properly mark emergency broadcast placard iaw 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: Emergency broadcast placard adequate.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 18 June 2008 Resolved
Provide senior deckhand letter, in lieu of operating with a mate iaw NVIC 01-91. Sr. Deckhand must be capable of performing master's duties.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 18 June 2008
Resolution: O/o was able to provide senior deckhand checklist that a deckhand on board had completed. Sr. Deckhand tested on return to port and asked to moor the vessel. SAT.
Construction/Loadline › Structures › Superstructure
Issued 18 June 2008 Resolved
Renew all mast hounds cracked or damaged. 46 CFR 176.500(b)(1)(iv)
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: All cracked mast hounds have been replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 18 June 2008 Resolved
Remove stores from all berths.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: Berthing areas are clear of stored items.
Fire Fighting › Combustible Materials › Insulation
Issued 18 June 2008 Resolved
Remove polystrene from pantry wire runs. 46 CFR 177.405
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: Pantry wire runs isnpected sat.
Electrical › Electric Supply System (service) › Cable
Issued 18 June 2008 Resolved
Properly support wire runs in the engine room every 24 inches with metallic supports 46 CFR 183.340
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: Wire runs in e/r are properly supported.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 18 June 2008 Resolved
Prove proper operation of 14 adult and 6 child PFD water lights per 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 1 October 2008
Resolution: All lights working properly.
Construction/Loadline › Hull › Hull Plating
Issued 26 December 2007 Resolved
Prior to carrying passengers, complete credit dry dock and internal structural exam, to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 10 January 2008
Resolved 23 April 2008
Resolution: Completed hull exam and part of ISE. CG-835 issued to complete ISE.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 18 June 2007 Resolved
Provide current Notice to Mariner prior to each time vessel gets underway
Due 25 July 2007
Resolved 27 August 2007
Resolution: Current Notice to Mariners was provided onboard.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 June 2007 Resolved
Replace line of bouy or replace entire life ring bouy.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 22 August 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 June 2007 Resolved
Provide approved up to date First Aid kit
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 22 August 2007
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 18 June 2007 Resolved
update emergency procedures to include throwing flotation device and ensuring that safety harness is attached to deckhand when retrieving victim from water
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 22 August 2007
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 August 2006 Resolved
Make available an updated copy of the Inland Rules of The Road.
Due 11 August 2006
Resolved 11 August 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 August 2006 Resolved
Repair exhaust leak on the main diesel engines exhaust line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2006
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 11 August 2006 Resolved
Repair deadend wiring in the fwd guest berthing area.
Due 11 August 2006
Resolved 11 August 2006
Engineering › Bilge Water Management System › Pump
Issued 11 August 2006 Resolved
Install self priming bilge pump in accordance with 46 CFR 182.520
Due 17 August 2006
Resolved 17 August 2006
Communications › Internal Communications System › Sound-powered Telephone
Issued 11 August 2006 Resolved
Install PA system to meet the requirements of 46 CFR 184.610. There are no speakers in the fwd and aft berthing area spaces.
Due 17 August 2006
Resolved 17 August 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 August 2006 Resolved
Install a bilge alarm system in the fwd bow thuster room
Due 17 August 2006
Resolved 17 August 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 August 2006 Resolved
Carry only 159 total persons until additional lifejacket is replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 August 2006 Resolved
Remove all stowage in the fwd berthing area
Due 17 August 2006
Resolved 17 August 2006
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 11 August 2006 Resolved
Remove flammable stores throughout vessel or provide a flammable stowage locker for the stowage of flammable stores.
Due 17 August 2006
Resolved 17 August 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2006 Resolved
Correct items noted on DAPI Audit Report. Item #2 on the report must be completed prior to carrying passengers
Due 17 August 2006
Resolved 17 August 2006
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 9 July 2004 Resolved
Provide proper non-combustable waste recepticles IAW 46 CFR 177.405
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2004
Resolved 16 July 2004
Lifesaving
Issued 3 July 2002 Resolved
REPLACE/REPAIR STROBE LIGHT FOR #1 LIFE FLOAT
Due 10 July 2002
Resolved 10 July 2002
Documentation › Markings/Placards
Issued 3 July 2002 Resolved
POST EMERGENCY BROADCAST PLACARD.
Due 3 August 2002
Resolved 4 July 2002
Documentation › Markings/Placards
Issued 3 July 2002 Resolved
POST EMERGENCY INSTRUCTIONS.
Due 3 August 2002
Resolved 3 July 2002
Lifesaving
Issued 5 July 2001 Resolved
VESSEL RESTRICTED TO WITHIN (3) MILES FROM SHORE UNTIL EXPIRED HYDROSTATIC RELEASE FOR EPIRB HAS BEEN REPLACED
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Construction/Loadline
Issued 5 July 2001 Resolved
PROPERLY LABEL BILGE HIGH WATER ALARMS AT OPERATING STATION TO DIFFERENTIATE BETWEEN THE SAME.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Lifesaving
Issued 5 July 2001 Resolved
PROPERLY SECURE CANONS ON AFT DECK PORT & STARBORD.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Unknown
Issued 17 July 2000 Resolved
PROVIDE PROPER PERMENANT VALVE HANDLE FOR GENERATOR RAW WATER INTAKE VALVE LOCATED IN THE ENGINE. CORRECTION SHALL BE MADE TO THE SATISFACTION OF THEATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Construction/Loadline
Issued 30 April 2000 Resolved
Prior to the carriage of passengers, provide proposal for & make permanent repairs to vessel's bow stem damage, in way of fwd peak tank and in way of parted bob stays. Repairs to be completed to the satisfaction of the at- tending marine inspector and the cognizant OCMI.
Condition: Unknown
Due 1 June 2000
Resolved 5 May 2000
Navigation
Issued 30 April 2000 Resolved
Prior to the carriage of passengers, make permanent repairs to the Engine Order Telegraph (EOT) cable/throttle system and prove proper operation of the same in the presence of and to the satisfaction of the attending marineinspector.
Condition: Unknown
Due 1 June 2000
Resolved 5 May 2000
Lifesaving
Issued 8 July 1999 Resolved
Provide and post crew station bill, in accordance with 46 CFR 185.514, no later than 30JUN99 & to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Documentation
Issued 9 July 1998 Resolved
Provide current FCC Great Lakes Agreement certificate to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 8 August 1998
Resolved 31 July 1998
Navigation
Issued 16 July 1997 Resolved
Provide current compass deviation table.
Condition: Unknown
Due 15 August 1997
Resolved 25 August 1997
Electrical
Issued 18 July 1996 Resolved
Install cover on electrical circuit breaker in starboard forward stateroom.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 18 July 1996 Resolved
Label watertight door below main deck "Watertight Door - Keep Closed", 1' letters, both sides.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 18 July 1996 Resolved
Install devise to secure open stern windows.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Documentation
Issued 18 July 1996 Resolved
Provide copy of Consortium Agreement to meet 46 CFR, Part 16, random drug testing requirements.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Lifesaving
Issued 18 July 1996 Resolved
Install safety lines between port and starboard ladder stanchion and deck railing.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Navigation
Issued 18 July 1996 Resolved
Install weathertight protective cover on steering mechanism.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Navigation
Issued 18 July 1996 Resolved
Provide updated Navigation Charts and Publications.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Lifesaving
Issued 18 July 1996 Resolved
Provide safety boundary top aft end of forward trunk top.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Engineering
Issued 18 July 1996 Resolved
Provide harness for jib boom operation.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Documentation
Issued 18 July 1996 Resolved
Provide most current lines of curvature drawings as submitted to Marine Safety Center for Stability Test information.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Documentation
Issued 18 July 1996 Resolved
Provide Employee Assistance Program for crew members.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 18 July 1996 Resolved
Move exhaust outlet to comply with approved plans, considering vessel's draft under full load conditions.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 18 July 1996 Resolved
Install/maintain the following sail riggings:_x001C_ a. Thimble on aft spanker bracket; b. Safety wires on all shackles;_x001C_ c. Tighten all loose standing rigging; d. Configure stopper knots on all dead-eye lanyards.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Lifesaving
Issued 18 July 1996 Resolved
Install access zippers on buoyant apparatus (remove covers while passengersare on board until zippers installed).
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 18 July 1996 Resolved
Mark permanent draft marks on hull.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Accommodation/Occupational Safety
Issued 18 July 1996 Resolved
Apply "non-skid" on all ladders.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Engineering
Issued 18 July 1996 Resolved
Install thermal guard on hydraulic reservoir, or provide means of cooling hydraulic oil.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996

Casualty record · 5

4 June 2011Routine · role: Involved in a Marine Casualty · activity 4045336
24 August 2012Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 4569137
26 June 2019Routine · role: Involved in a Marine Casualty · activity 6743181
29 June 2019Routine · role: Involved in a Marine Casualty · activity 6743704
30 May 2021Routine · role: Involved in a Marine Casualty · activity 7212017
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.