THE KRAKEN

THE KRAKEN is a 2001 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2001, most recently in June 2025, along with 61 deficiencies, 3 operational controls and 4 casualty investigations between 2002 and 2007.

Records from 2001 to 2025. Most recent: inspection, 11 June 2025.

Built
2001
Last inspected
11 June 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI7805
Flag
UNITED STATES
367732380
Maury page id
psix-30806

Inspections, by type

…with no type recorded6
Years with a record 19 calendar years (2001–2025)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)27.0 ft × 10.2 ft × 5.1 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPREMIUM PARASAIL BOATS · CAPE CORAL, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portDANA POINT, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7805MMSI 367732380 · active · compulsorily equipped · granted 10 June 2026, expires 5 May 2036
WDG3331MMSI 367524930 · expired · compulsorily equipped · granted 10 April 2012, cancelled 11 June 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDB5289MMSI 366907970 · expired · compulsorily equipped · granted 23 September 2003, cancelled 23 November 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AIRGASM Passenger (Inspected) · MISLE 21281 · 18 March 2004 · activity 2635591

Inspection history · 33

11 June 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8092569
24 October 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024283
30 May 2024 Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7890190
25 July 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7665896
14 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650892
9 May 2022 Hull Examination · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7427360
1 June 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7206614
24 July 2020 Internal Structural Exam · Hull Examination · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7015387
31 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732629
28 May 2019 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6697134
1 June 2018 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6427648
1 September 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6243530
24 January 2017 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6024904
18 May 2016 COI Inspection · Deficiency Check · Hull Examination · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5868445
17 November 2015 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5764935
15 July 2015 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5185065
4 June 2012 Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4333374
7 May 2012 Internal Structural Exam · Administrative Inspection · Simplified Stability Test · COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4308779
20 January 2012 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235124
13 March 2007 Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2887428
13 March 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2902464
12 March 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2886850
5 March 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2883360
1 August 2006 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2724236
19 August 2005 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2467113
24 September 2004 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2153966
18 March 2004 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2635591
27 October 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1936998
20 August 2003 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1879600
11 November 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1723414
9 August 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1658324
4 October 2001 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 1496683
31 July 2001 COI Inspection · Hull Examination · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391649

Deficiency record · 61

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 May 2024 Resolved
Each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 6 inches above the deepest load waterline must have means to prevent water from entering the vessel. Bilge discharge piping from the engine room space (amidships, port side) was not fitted with a non-return valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 24 October 2024
Resolution: Resolved previously in activity 7890190
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2024 Resolved
A power-driven vessel underway shall exhibit sidelights. The vessel's port and starboard navigation lights were found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 24 October 2024
Resolution: Resolved previously in activity 7890190
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 30 May 2024 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. An anchor was not maintained on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 24 October 2024
Resolution: Resolved previously in activity 7890190
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2023 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. A suitable metal marine type strainer must be fitted in the fuel supply line in the engine compartment. The main diesel engine fuel filter was fitted with a plastic petcock.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 9 August 2023
Resolution: Vessel owner provided picturs of a metal petcock installed on the fuel filter.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 May 2022 Resolved
A Vessel on a Limited Coastwise route must carry six red hand flares and six orange smoke signals. Vessel had onboard 04 red hand flares and 03 orange smoke signals. Vessel to provide 06 red hand flares and 06 orange smoke flares, vessel restricted to a Lakes, Bays, and Sounds route.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 14 March 2023
Resolution: Received SAT proof of 06 red hand flares and 06 orange smoke flares on board. Deficiency cleared.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 May 2022 Resolved
When conducting alcohol testing an individual must provide a specimen of their breath, blood, or saliva. Onboard alcohol swabs are expired. Vessel to provide up to date alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 14 March 2023
Resolution: Provided proof of valid alcohol swabs on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 May 2022 Resolved
Every vessel subject to part III of title III of the Communications Act must have a detailed inspection of the radio installation every 5 years. Vessel's Radiotelephony Certificate is expired. Vessel to provide valid certificate. 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 10 April 2023
Resolution: Receieved photo evidence of valid radiotelephony certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2020 Resolved
Vessels in salt water are required to under dry dock inspection every two years. vessel is overdue for drydock. Vessel may not operate with greater than 6 passengers on board until dry dock is completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2020
Resolution: Vessel successfully completed a Hull exam for credit drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2020 Resolved
A vessel of more than 26' in length but not over 65', must carry a minimum of one life buoy of not less than 24". Ring buoy is weathered, name is faded and light is in-op. Replace ring buoy and light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 6 August 2020
Resolution: Vessel provided new ring buoy and an operation light.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 31 July 2019 Resolved
THE OWNER OR OPERATING MANAGER MUST PROVIDE SATISFACTORY EVIDENCE THAT THE NECCESARY MAINTENANCE PROCEDURES HAVE BEEN CONDUCTED. NO SERVICING CONDUCTED IN LAST YEAR. SCHEDULE SERVICE AND PROVIDE SATISFACTORY SERVICE REPORT.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2019
Resolution: OWNER / OPERATOR PROVIDED SATISFACTORY SERVICING REPORT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 July 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2019
Resolution: OWNER / OPERATOR RECTIFIED DEFICENCY TO SATISFACTION OF COAST GUARD MARINE INSPECTOR.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 July 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 1 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 July 2019 Resolved
VESSEL MUST CARRY UP TO DATE CHARTS. CHART IS FROM 2016 WITH NO UPDATES OR ARCHIVED NOTICE TO MARINERS. PROVIDE UPDATED CHART.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 9 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2019 Resolved
VESSEL SHALL BE PROVIDED WITH SOME MEANS OF PRODUCING SUFFICIENT SOUND SIGNAL. NO SOUND SIGNAL AVAILABLE FOR INSPECTION. PROVIDE SATISFACTORY SOUND SIGNAL.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 1 August 2019
Communications › Radio Communications › VHF Radiotelephone
Issued 1 June 2018 Resolved
Provide marine operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 28 May 2019
Resolution: Vessel provided Marine Operator permit.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 1 June 2018 Resolved
Provide liferaft inforamtion (servicing or new?) for 6 man IBA, w/ installation details.
Action required: 705 - Other - as specified
Due 1 January 2019
Resolved 28 May 2019
Resolution: Vessel provided proof of approved liferaft. To be installed & verified at upcoming annual.
Lifesaving › Lifebuoys › Approval
Issued 1 September 2017 Resolved
Replace white life ring buoy with CG approved orange buoy.
Condition: Improper Installation
Due 1 September 2017
Resolved 8 September 2017
Resolution: White life ring buoy was replaced with satisfactory orange buoy.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 1 September 2017 Resolved
Provide servicing certificate for current fixed fire system.
Due 1 September 2017
Resolved 1 September 2017
Resolution: Servicing tech conducted required servicing and submitted servicing report. All sat.
Stability › Watertight Integrity › General
Issued 1 September 2017 Resolved
Replace worn gasket on Engine Compartment to maintain watertight integrity.
Condition: Improper/Lack of Maintenance
Due 15 September 2017
Resolved 8 September 2017
Resolution: Worn gasket material was replaced around engine compartment.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 September 2017 Resolved
Ensure EPIRB is tested and logged monthly.
Condition: Improper/Lack of Maintenance
Due 1 September 2017
Resolved 1 September 2017
Resolution: Owner tested EPIRB on the spot and began entry to log monthly tests.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 May 2016 Resolved
Replace battery in Ring Lifebuoy
Due 18 May 2016
Resolved 18 May 2016
Stability › Watertight Integrity › General
Issued 18 May 2016 Resolved
Provide proof of a new gasket on the engine compartment hatch.
Due 1 June 2016
Resolved 1 June 2016
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 18 May 2016 Resolved
Provide fire retardant material to sheath the engine room compartment.
Due 1 June 2016
Resolved 1 June 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 May 2016 Resolved
Provide emergency instructions and emergency radio procedures
Due 1 June 2016
Resolved 1 June 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 June 2012 Resolved
Label life jacket location.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2012
Resolved 15 June 2012
Resolution: Life jacket location properly labeled with correct size/number of jackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 June 2012 Resolved
Mount life ring light and attach to the life ring.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2012
Resolved 15 June 2012
Resolution: Life ring light mounted and attached to life ring.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 June 2012 Resolved
Affix name of vessel and homeport to the stern of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 15 June 2012
Resolution: Name of vessel and homeport affixed to the stern of the vessel.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2012 Resolved
Provide updated COD upon receipt.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 15 June 2012
Resolution: Provided updated copy of COD.
Operations/Management › Drills/Instruction › Fire
Issued 7 May 2012 Resolved
Demonstrate fire & abandon ship drills. IAW46CFR185.524 & 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2012
Resolution: Master and crew preformed a satisfactory MOB, fire and abandon ship drills.
Operations/Management › Passenger Operations › Safety Orientation
Issued 7 May 2012 Resolved
Demonstrate parasail equipment operation. IAW46CFR185.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2012
Resolution: Parasail operations were witnesses by Attending Marine Inspector.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 May 2012 Resolved
Notify OCMI changes in Owner/Operator. IAW46CFR176.120.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2012
Resolved 25 May 2012
Resolution: Provided copy of COD.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 May 2012 Resolved
Notify OCMI when New to Zone and operating w/ more than 6 passengers. IAW46CFR176.120.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2012
Resolution: Owner notified OCMI by scheduling New to Zone Inpsection and filling out an Application for Inspectiomn.
Engineering › Steering Gear System › Linkage
Issued 13 March 2007 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVE PROPER OPERATION OF ENGINE AND OUTDRIVE. GIMBAL BEARING EXPLODED AND BROKE THE GIMBAL HOUSING APART.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 16 March 2007
Resolution: NEW GIMBAL HOUSING AND BEARING INSTALLED. CONDUCTED A SATISFACTORY U/W CHECK RIDE.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, repair or replace emergency fuel stop lever.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 24 September 2004 Resolved
Prior to carriage of passengers, repair or replace engine room vapor detector.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, repair or replace gasoline tank void, vapor detector.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, repair or replace engine room bilge high level alarm.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, repair or replace FWD void bilge high level alarm.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Lifesaving › Hand Flares › Expired
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, provide 12 red day/night hand held flares as per 46CFR180.68.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, repair or replace float light for ring life buoy.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Communications › Radio Communications › EPIRB
Issued 24 September 2004 Resolved
Have EPIRB antenna repaired or replaced, and tested by a licensed third party.
Condition: Improper/Lack of Maintenance
Due 1 October 2004
Resolved 30 September 2004
Lifesaving › Buoyant Apparatus › Painter
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, provide a lanyard for floatlight IAW 46CFR180.70(d)(1)&(2).
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Lifesaving › Buoyant Apparatus › Marking
Issued 24 September 2004 Resolved
Re-stencil name of vessel on ring life buoy.
Condition: Improper/Lack of Maintenance
Due 1 October 2004
Resolved 30 September 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, provide 2004 Documentation.
Condition: Unknown
Due 24 September 2004
Resolved 30 September 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 24 September 2004 Resolved
Prior to the carriage of passengers, provide one Type B-I and one Type A-II portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 September 2004 Resolved
Prior to night time operation, repair STBD navigation light.
Condition: Improper/Lack of Maintenance
Due 24 September 2004
Resolved 30 September 2004
Communications › Radio Communications
Issued 20 August 2003 Resolved
PROVIDE CURRENT FCC STATION LICENSE. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Unknown
Due 1 September 2003
Resolved 27 October 2003
Communications › Radio Communications
Issued 20 August 2003 Resolved
PROVIDE CURRENT FCC RADIOTELEPHONE SAFETY CERTIFICATE. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Unknown
Due 1 September 2003
Resolved 27 October 2003
Fire Fighting › Fixed Fire Detection System
Issued 20 August 2003 Resolved
REPAIR ENGINE ROOM OXYGEN CENSOR PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: 02 Censor
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 21 August 2003
Resolution: FAX DOCUMENTATION.
Communications › Radio Communications
Issued 20 August 2003 Resolved
PROVIDE CURRENT EPIRB REGISTRATION. LEGACY COMPONENT DESC: EPIRB
Due 1 September 2003
Resolved 27 October 2003
Communications › Radio Communications › EPIRB
Issued 20 August 2003 Resolved
PROVIDE PROOF OF EPIRB HYDROSTATIC RELEASE EXPIRATION.
Due 1 September 2003
Resolved 21 August 2003
Resolution: FAX DOCUMENTATION.
Lifesaving › Lifejacket/PFD (Type IV)
Issued 20 August 2003 Resolved
REPLACE 24" LIFERING WITH 60' OF FLOATABLE LINE, RETOFLECTIVE MATERIAL AND VESSEL NAME PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 21 August 2003
Resolution: FAX DOCUMENTATION.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 20 August 2003 Resolved
PROVIDE ONE ADDITIONAL USCG MARINE TYPE B-II FIRE EXTINGUISHER PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Due 1 September 2003
Resolved 21 August 2003
Resolution: FAX DOCUMENTATION.
Operations/Management › Drug and Alcohol Testing
Issued 20 August 2003 Resolved
PROVIDE CURRENT CHEMICAL TESTING PROGRAM CREW LIST. LEGACY COMPONENT DESC: Employee Coverage
Due 1 September 2003
Resolved 27 October 2003
Operations/Management › Drills/Instruction
Issued 20 August 2003 Resolved
POST ENGINE ROOM BLOWER WARNING PLACARD. LEGACY COMPONENT DESC: Warning Placard
Condition: Improper Installation
Due 1 September 2003
Resolved 27 October 2003
Engineering › Gasoline Engine (propulsion)
Issued 9 August 2002 Resolved
Provide an interlock switch as per 46CFR182.460(e). LEGACY COMPONENT DESC: Ventilation
Due 9 September 2002
Resolved 20 August 2003
Resolution: SAT.
Engineering › Gasoline Engine (propulsion)
Issued 9 August 2002 Resolved
Provide two blower motors as per 46CFR182.460(c). LEGACY COMPONENT DESC: Ventilation
Due 9 September 2002
Resolved 20 August 2003
Resolution: CURRENT SYSTEM MEETS ABYC SATANDARDS.
Engineering › Gasoline Engine (propulsion)
Issued 9 August 2002 Resolved
Provide a mechanical exhaust system as per 46CFR182.460(a)(1)(ii). LEGACY COMPONENT DESC: Ventilation
Due 9 September 2002
Resolved 20 August 2003
Resolution: CURRENT SYSTEM MEETS ABYC STANDARDS.
Engineering › Gasoline Engine (propulsion)
Issued 9 August 2002 Resolved
Provide rigid permanent constructed ducts as per 46CFR182.460(h). LEGACY COMPONENT DESC: Ventilation
Due 9 September 2002
Resolved 20 August 2003
Resolution: CURRENT SYSTEM MEETS ABYC STANDARDS.
Communications › Alarms/Indicators
Issued 9 August 2002 Resolved
Repair audible alarms for both bilge high water level alarm system. LEGACY COMPONENT DESC: Bilge Alarm
Due 9 September 2002
Resolved 20 August 2003
Resolution: SAT.
Documentation
Issued 31 July 2001 Resolved
PRIOR TO 02SEP01, PROVIDE A FCC STATION LICENSE AND A FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 30 August 2001
Resolved 5 September 2001

Casualty record · 4

11 November 2002Routine · role: Involved in a Marine Casualty · 2 injured · activity 1723414
5 March 2007Routine · role: Involved in a Marine Casualty · activity 2883360
12 March 2007Routine · role: Involved in a Marine Casualty · activity 2886850
13 March 2007Routine · role: Involved in a Marine Casualty · activity 2902464
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TICA (2002–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.