AIRGASM is a 2000 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2001, most recently in October 2025, along with 55 deficiencies and 7 casualty investigations between 2006 and 2018.

Records from 2001 to 2025. Most recent: inspection, 2 October 2025.

Built
2000
Last inspected
2 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF2334
Flag
UNITED STATES
367427510
Maury page id
psix-21281

Inspections, by type

…with no type recorded11
Years with a record 18 calendar years (2001–2025)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portMADEIRA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 August 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF2334MMSI 367427510 · active · compulsorily equipped · granted 27 August 2019, expires 8 October 2029
WDC2483MMSI 366993750 · expired · voluntarily equipped · granted 25 November 2004, cancelled 31 January 2015
WDA4250MMSI 366807370 · expired · compulsorily equipped · granted 12 April 2001, cancelled 18 June 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GET N HIGH Passenger (Inspected) · MISLE 933073 · 8 June 2018 · activity 6441157LONGEST RIDE Passenger (Uninspected) · MISLE 34484 · 1 April 2009 · activity 3444182LONGEST RIDE Passenger (Uninspected) · MISLE 34484 · 30 March 2009 · activity 3443872THE KRAKEN Passenger (Inspected) · MISLE 30806 · 18 March 2004 · activity 2635591

Inspection history · 39

2 October 2025 COI Inspection · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8220462
5 November 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6849510
18 October 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6518123
28 August 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6528622
8 June 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6441157
19 October 2017 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6291046
31 January 2017 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6077530
12 December 2016 Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6052535
11 August 2016 COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5969492
5 April 2016 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5853430
4 April 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5853459
19 November 2015 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5766452
29 October 2015 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5753584
14 May 2012 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4306537
20 January 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4231388
11 August 2011 Simplified Stability Test · Hull Examination · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4118303
20 September 2010 DAPI Audit · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3858377
25 March 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3733413
1 April 2009 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3444182
30 March 2009 Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3442556
30 March 2009 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3443872
28 October 2008 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3356893
4 April 2007 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2901639
10 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2640519
7 April 2005 Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2327810
6 April 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2327853
6 December 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2255723
9 November 2004 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2238834
18 March 2004 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2635591
27 February 2004 Annual Inspection · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2012994
26 March 2003 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1793980
24 February 2003 Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1740700
12 April 2002 In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1604148
12 February 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1603925
1 November 2001 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 773087
23 October 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1468251
10 May 2001 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063428
10 May 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063527
22 February 2001 Hull Examination · Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1389318

Deficiency record · 55

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 November 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable section sof the international navigation rules. The starboard navigational light was not operating as designed. Repair or replace.
Action required: 705 - Other - as specified
Due 22 November 2019
Resolved 2 October 2025
Resolution: Nav light was replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:... A means to reset devices used to automatically shut down ventilation systems and engines as required. The override switch was inoperable. Repair/replace. 46 CFR 181.420(b)(3)
Action required: 705 - Other - as specified
Due 22 November 2019
Resolved 2 October 2025
Resolution: Override switch was repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2019 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock and an internal structural examination at least once every two years. Vessel exceeded drydock and internal structural examination date of 10/31/2019. IAW: 46 CFR 176.600 (c) (1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: New hull and ISE exam were conducted with 0 deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2018 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a), provided that a positive metallic shutoff valve is installed at the hull penetration. MI observed that all (04) electric submersible pumps on board lacked a shutoff valve at the hull penetration. Install shutoff valves for bilge pump discharge. 46 CFR 182.520 (e) (7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2018
Resolved 2 November 2018
Resolution: Metallic shutoff valves have been installed for all four bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2018 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have at the operating station a means to reset devices used to automatically shut down ventilation systems and engines. MI observed engine shut down override for fixed gas fire extinguishing was inoperable. Repair or Replace. 46 CFR 181.420 (b) (3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2018
Resolution: A new override switch was installed for the fixed gas fire extinguishing system. MI witnessed satisfactory test.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 October 2017 Resolved
Provide bracket for portable fire extinguisher at operator station. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 9 November 2017
Resolution: Bracket provided for additional portable fire extinguisher to the satisfaction of the Marine Inspector.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 August 2016 Resolved
Renew Bilge pump strainer as per the requirement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 29 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 11 August 2016 Resolved
Repair waterlight battery connections to ensure fixed connections as per requirement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 29 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 November 2015 Resolved
Provide cover or guard for exposed belts on the forward section of the main diesel engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 5 May 2016
Resolution: A guard was place over rotating machinery.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 November 2015 Resolved
Ensure battery is mounted in an electrolyte resistance tray.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 14 December 2015
Resolution: O/O fabricated tray from electrolyte resistant material.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 November 2015 Resolved
Provide visual high level bilge alarm for forward bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 14 December 2015
Resolution: New high level alarms installed.
Communications › Radio Communications › EPIRB
Issued 19 November 2015 Resolved
Renew expired hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 19 November 2015
Resolution: Renewed hydrostatic release with spare on hand.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 November 2015 Resolved
Provide current light list and coast pilot for operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 14 December 2015
Resolution: Sections of light list and Coast Pilot pertaining to the vessels AOR were printed by owner.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 November 2015 Resolved
Provide curent MIS report for company's drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 3 December 2015
Resolution: Received MIS Report.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 August 2011 Resolved
Provide up to date navigation chart to be within one year of mfgr or updated with most recent notice to mariners. Local policy and 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2011
Resolved 12 September 2011
Resolution: New chart provided by owner.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 20 September 2010 Resolved
Provide proof of enrollment in current drug & alcohol program as per 46CFR16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2010
Resolution: Received email proof of enrollment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 20 September 2010 Resolved
Provide proof of B-1 fire extinguisher required on vessel per 46CFR181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2010
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 28 October 2008 Resolved
Replace/Renew Flex Fuel Fill Lines w/CG approved J1942 hoses for both fuel tanks.
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 15 December 2008
Engineering › Fuel Oil Service System › Hose
Issued 28 October 2008 Resolved
Double clamp all fuel, cooling, & oil hoses.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 5 December 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 October 2008 Resolved
Remove wing nuts at battery terminals.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 5 December 2008
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 28 October 2008 Resolved
Provide proof that blowers to engine compartment will insure one complete change of air prior to starting engine (interlock with starting switch).
Action required: 705 - Other - as specified
Due 18 December 2008
Resolved 15 December 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 28 October 2008 Resolved
Provide a B-II portable fire extinguisher with appropriate mounting bracket for Engine Compartment.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 5 December 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 28 October 2008 Resolved
Provide an Emergency broadcast placard at the operating station.
Action required: 705 - Other - as specified
Due 28 November 2008
Resolved 5 December 2008
Documentation › Certificates/Documents › FCC SSL
Issued 10 May 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 24 May 2006
Resolved 24 May 2006
Resolution: HE RCVD HIS LIC ON 17MAY06.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 May 2006 Resolved
Update nautical publication. They were missing the cost pilot and light list. Gave them a copy of the web sites so they can down load the information for vessel.
Condition: Improper/Lack of Maintenance
Due 24 May 2006
Resolved 24 May 2006
Resolution: CORRECTED
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 10 May 2006 Resolved
Provide a emergency broadcast placard. Placard was removed when cleaning vessel.
Condition: Improper/Lack of Maintenance
Due 24 May 2006
Resolved 24 May 2006
Resolution: PLACED ONBOARD
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 April 2005 Resolved
As per 46CFR176.600(a), operator did not make vessel available for a dry dock examination on or before February 24, 2005 as stated on COI.
Condition: Improper/Lack of Maintenance
Due 7 April 2005
Resolved 7 April 2005
Engineering › Gasoline Engine (propulsion) › Connecting Rod (4 cycle)
Issued 27 February 2004 Resolved
INSTALL MACHINERY GUARD OVER ENGINE SHAFT COUPLING. LEGACY COMPONENT DESC: Machinery Guard
Due 27 March 2004
Resolved 9 November 2004
Resolution: PHOTOGRAPHIC DOCUMENTATION.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 February 2004 Resolved
PROVIDE FCC STATION LICENSE. LEGACY COMPONENT DESC: FCC
Due 27 March 2004
Resolved 22 December 2004
Resolution: ISSUED 25NOV04 EXP. 25NOV14.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 February 2004 Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE. LEGACY COMPONENT DESC: FCC
Due 27 March 2004
Resolved 22 December 2004
Resolution: ISSUED 22DEC04 EXP. 22DEC09.
Lifesaving › Lifejacket/PFD (Type V) › Retroreflective Material
Issued 24 February 2003 Resolved
INSTALL RETRO ON BOTH SIDES OF LIFERING PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Improper Installation
Due 3 March 2003
Resolved 24 March 2003
Resolution: FAXED RECEIPT.
Lifesaving › Lifejacket/PFD (Type V) › Lights
Issued 24 February 2003 Resolved
PROVIDE FLOATING WATERLIGHT WITH 6' OF FLOATING LINE AND DETACHABLE LINK PRIOR TO CARRIGE OF PASSENGERS.
Condition: Improper Installation
Due 3 March 2003
Resolved 24 March 2003
Resolution: FAXED RECEIPT.
Engineering › Bilge Water Management System
Issued 24 February 2003 Resolved
INSTALL POSITIVE CLOSURE DEVICES ON EACH BILGE DISCHARGE AT HULL PENETRATION. LEGACY COMPONENT DESC: Vent
Condition: Improper Installation
Due 8 March 2003
Resolved 27 February 2004
Resolution: SAT
Operations/Management › Drug and Alcohol Testing
Issued 24 February 2003 Resolved
PROVIDE CURRENT CREW LIST AND CONSORTIUM CONTRACT.
Condition: Unknown
Due 8 March 2003
Resolved 27 February 2004
Resolution: SAT
Communications › Radio Communications
Issued 24 February 2003 Resolved
PROVIDE PROOF OF 406MHZ EPIRB REGISTRATION. LEGACY COMPONENT DESC: EPIRB
Condition: Improper Installation
Due 24 March 2003
Resolved 27 February 2004
Resolution: SAT
Construction/Loadline › Structures
Issued 24 February 2003 Resolved
REPAIR VAPOR TIGHT FITTING IN STARBOARD FORWARD ENGINE ROOM AT BULKHEAD/HULL INTERSECTION. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Damaged By Earlier Event
Due 8 March 2003
Resolved 27 February 2004
Resolution: SAT
Construction/Loadline
Issued 23 October 2001 Resolved
PRIOR TO THE VESSEL BEING PLACED IN OPERATION CARRYING MORE THAN 6 PASSENGERS FOR HIRE, REPAIR ALL AREAS OF DELAMINATION AS INDICATED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 April 2002
Resolved 12 February 2002
Resolution: All areas of noted delamination had been properly repaired.
Fire Fighting
Issued 10 May 2001 Resolved
PROVIDE ANNUAL SERVICING REPORT FOR FIXED FIRE SYSTEM.
Condition: Unknown
Due 10 June 2001
Resolved 30 June 2001
Documentation
Issued 10 May 2001 Resolved
PROVIDE PROOF OF ENROLLMENT TO APPROVED DRUG PROGRAM OF ALL MATES.
Condition: Unknown
Due 10 June 2001
Resolved 30 June 2001
Documentation
Issued 22 February 2001 Resolved
Provide drug testing.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Documentation
Issued 22 February 2001 Resolved
Provide training log.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Navigation
Issued 22 February 2001 Resolved
Provide charts and pubs for operating area.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide(3) red flares and (3) orange smoke distress signals for a limited coastwise route.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 22 February 2001 Resolved
Provide starter and ignition interlock IAW 46 CFR 182.460 (e).
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 22 February 2001 Resolved
Provide warning label for starter IAW 46 CFR 182.460 (e).
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Navigation
Issued 22 February 2001 Resolved
Provide anchor light.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Documentation
Issued 22 February 2001 Resolved
Provide FCC documentation.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide life floats as required by OCMI for operating area.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Fire Fighting
Issued 22 February 2001 Resolved
Prove operation of engine shutdowns for fixed fire fighting system.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 22 February 2001 Resolved
Permanently mark O.N. on hull IAW 46 CFR 67.121.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide approved first aid kit IAW 46 CFR 160.041
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide authorized crew.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Properly install waterlight on life ring IAW 46 CFR 180.70(d)
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 22 February 2001 Resolved
OCMI to determine operating area for EPIRB requirements.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Mark flare box "DISTRESS SIGNALS".
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001

Casualty record · 7

14 August 2006Routine · role: Involved in a Marine Casualty · activity 2752053
30 March 2009Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 3443872
25 March 2010Routine · role: Involved in a Marine Casualty · activity 3733413
28 April 2014Routine · role: Involved in a Marine Casualty · activity 4851596
10 April 2015Routine · role: Involved in a Marine Casualty · activity 5101996
4 April 2016Routine · role: Involved in a Marine Casualty · activity 5853459
8 June 2018Routine · role: Sighted in Area · serious marine incident, as classified · 5 injured · activity 6441157
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record