MAURY USCG vessel records
← All vessels

AIRGASM

Built
2000
Last inspected
2 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 October 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF2334
Flag
UNITED STATES
Maury page id
psix-21281

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portMADEIRA BEACH, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 August 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 11 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GET N HIGH Passenger (Inspected) · MISLE 933073 · 8 June 2018 · activity 6441157

Inspection history · 11

2 October 2025 COI Inspection · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8220462
5 November 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6849510
18 October 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6518123
28 August 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6528622
8 June 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6441157
19 October 2017 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6291046
31 January 2017 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6077530
12 December 2016 Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6052535
11 August 2016 COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5969492
5 April 2016 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5853430
4 April 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5853459

Deficiency record · 8

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 November 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable section sof the international navigation rules. The starboard navigational light was not operating as designed. Repair or replace.
Action required: 705 - Other - as specified
Due 22 November 2019
Resolved 2 October 2025
Resolution: Nav light was replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 November 2019 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:... A means to reset devices used to automatically shut down ventilation systems and engines as required. The override switch was inoperable. Repair/replace. 46 CFR 181.420(b)(3)
Action required: 705 - Other - as specified
Due 22 November 2019
Resolved 2 October 2025
Resolution: Override switch was repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2019 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock and an internal structural examination at least once every two years. Vessel exceeded drydock and internal structural examination date of 10/31/2019. IAW: 46 CFR 176.600 (c) (1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2025
Resolution: New hull and ISE exam were conducted with 0 deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2018 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a), provided that a positive metallic shutoff valve is installed at the hull penetration. MI observed that all (04) electric submersible pumps on board lacked a shutoff valve at the hull penetration. Install shutoff valves for bilge pump discharge. 46 CFR 182.520 (e) (7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2018
Resolved 2 November 2018
Resolution: Metallic shutoff valves have been installed for all four bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2018 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have at the operating station a means to reset devices used to automatically shut down ventilation systems and engines. MI observed engine shut down override for fixed gas fire extinguishing was inoperable. Repair or Replace. 46 CFR 181.420 (b) (3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2018
Resolution: A new override switch was installed for the fixed gas fire extinguishing system. MI witnessed satisfactory test.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 October 2017 Resolved
Provide bracket for portable fire extinguisher at operator station. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 9 November 2017
Resolution: Bracket provided for additional portable fire extinguisher to the satisfaction of the Marine Inspector.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 August 2016 Resolved
Renew Bilge pump strainer as per the requirement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 29 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 11 August 2016 Resolved
Repair waterlight battery connections to ensure fixed connections as per requirement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 29 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.

Ownership record