MAUNA KEA

Built
1988
Last inspected
14 August 2018
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 14 August 2018
…with no type recorded13
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1988–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

308955
Flag
UNITED STATES
Maury page id
psix-308955

Documentation record

Tonnage as PSIX records it2473 - Regulatory (Subpart C or D), Gross Ton
2473 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 58 inspections, each with its date, unit and type; 60 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CLAYTON ARTHUR Towing Vessel · MISLE 44914 · 15 May 2001 · activity 152072DEBRA C Towing Vessel · MISLE 110447 · 5 January 2001 · activity 18044DEBRA C Towing Vessel · MISLE 110447 · 2 January 1997 · activity 46840

Inspection history · 58

14 August 2018 Load Line/Change of Employment · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6511704
30 November 2010 Load Line/Change of Employment · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3902341
12 May 2008 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3214715
26 September 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3066948
13 September 2006 MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2757724
29 November 2005 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2543399
6 October 2005 MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2507771
30 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2322866
8 October 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2224074
18 June 2004 MTSA Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2086394
20 May 2004 MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2074462
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971501
9 September 2003 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1888016
18 July 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1849224
3 July 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1637253
11 April 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1603858
15 May 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 152072
9 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1425125
5 January 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 18044
12 May 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393432
9 July 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1098211
11 June 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1413555
25 August 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1131851
21 August 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1451317
30 July 1998 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 794802
11 June 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 792537
15 May 1998 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416707
18 March 1998 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368645
12 June 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396748
2 January 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 46840
17 May 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1452164
29 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661233
29 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661234
19 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 112367
15 June 1995 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1419442
18 May 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 874571
17 May 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 196212
17 May 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 752718
25 January 1995 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1463875
27 December 1994 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1164043
7 July 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 866439
8 June 1994 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382792
14 April 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661226
2 April 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 498263
9 July 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 844984
6 July 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 845514
30 July 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961241
2 July 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1268841
1 August 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1252388
5 July 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937805
20 November 1990 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902681
26 October 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229063
5 July 1990 Deficiency Check · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1236738
3 August 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213710
6 July 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034483
24 January 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 482014
25 August 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1037343
1 July 1988 Hull Examination · Construction Oversight · Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1206685

Deficiency record · 60

Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 September 2007 Resolved
Make all doors, hatches and covers located on deck watertight
Condition: Improper/Lack of Maintenance
Due 26 October 2007
Resolved 29 November 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 September 2007 Resolved
Repair wasted guard rails on main deck.
Condition: Improper/Lack of Maintenance
Due 26 October 2007
Resolved 29 November 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 September 2007 Resolved
Found oily water mixture in machinery space bildge.
Condition: Improper/Lack of Maintenance
Due 26 October 2007
Resolved 29 October 2007
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 26 September 2007 Resolved
Edit SOPEP to reflect vessel's new name. "Islander to Mauna Kea".
Condition: Improper/Lack of Maintenance
Due 26 October 2007
Resolved 29 October 2007
Construction/Loadline › Structures › Scuttle
Issued 12 September 2006 Resolved
Provide hatch for quick acting water tight scuttle for stbd engine room.
Condition: Unknown
Due 1 October 2006
Resolved 6 November 2006
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2006 No resolution recorded
Provide hull gauging report prior to next dry-dock to local OCMI.
Condition: Unknown
Due 22 August 2008 — due date passed with no resolution recorded
Fire Fighting › Fixed Fire Detection System
Issued 9 September 2003 Resolved
Prove proper operation of high temperature sensors for the machinery space. LEGACY COMPONENT DESC: Heat Detectors
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2003
Documentation › Certificates/Documents
Issued 9 September 2003 Resolved
Provide copies of Classification and International Loadline Certificates reflecting approved extensions by ABS or provide copies of newly issued certificates. LEGACY COMPONENT DESC: International Load Line Certificate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2003
Fire Fighting › Ventilation Systems
Issued 3 July 2002 Resolved
Apply "Open / Close" markings on fire damper manual controllers. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002 Resolved
Install support clips for electical wire ajacent to port fire damper manual clontroller. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 5 July 2002
Resolved 11 July 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002 Resolved
Remove or make safe the dead-end electrical wire below the port fire damper manual controller. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 July 2002 Resolved
Apply "Do not obstruct" markings on emergency escape scuttles. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Construction/Loadline › Structures
Issued 3 July 2002 Resolved
Replace missing studs on manholes at voids 1S, 3S and 5S. LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 3 July 2002 Resolved
Make operable all safety chains for deck rails at side ladder ports. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Electrical › Electrical Distribution System (service)
Issued 3 July 2002 Resolved
Provide non-conductive mat on deck at capstan controller panel in forecastle. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Construction/Loadline › Structures
Issued 3 July 2002 Resolved
Replace missing gasket on manhole at ballast tank 6P. LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 11 July 2002
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 July 2002 Resolved
Renew expired Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 3 July 2002
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 July 2002 Resolved
Paint faded/worn draft marks at stbd aft corner.
Condition: Improper/Lack of Maintenance
Due 5 July 2002
Resolved 3 July 2002
Engineering
Issued 12 May 2000 Resolved
Provide and install mechanical plugs missing from containment areas around fuel fill line and fuel tank vents. 33CFR155.320
Condition: Unknown
Due 12 May 2000
Resolved 18 May 2000
Unknown
Issued 12 May 2000 Resolved
Install bolted cover on flange face of standard discharge connection. _x001C_ 33CFR155.430
Condition: Unknown
Due 12 May 2000
Resolved 18 May 2000
Documentation
Issued 12 May 2000 Resolved
Aquire and implement an oil record book for tracking oil transfer & disposal. 33CFR155.820
Condition: Unknown
Due 12 May 2000
Resolved 18 May 2000
Electrical
Issued 11 June 1999 Resolved
Install metal wire ties on new wire runs to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 11 June 1999 Resolved
Remove jumper from face of the main switchboard to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 11 June 1999 Resolved
Install metal wire ties to bilge high level sensor to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Accommodation/Occupational Safety
Issued 11 June 1999 Resolved
Replace blower motor for the #1 starboard double void to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 11 June 1999 Resolved
Replace light cover on deck light, main deck port side to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Accommodation/Occupational Safety
Issued 11 June 1999 Resolved
Instal screens on air vents in machinery space to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Accommodation/Occupational Safety
Issued 11 June 1999 Resolved
Prove proper operation of the hand lifting gear for relief valve on the #3 pressure vessel to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 11 June 1999 Resolved
Hard wire refrigerator, grinder, and water fountain to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Unknown
Issued 15 May 1998 Resolved
PROVE PAYMENT OF USCG USER FEE FOR PERIOD 01JUL96 - 30JUN97.
Condition: Unknown
Due 15 May 1998
Resolved 15 May 1998
Fire Fighting
Issued 15 May 1998 Resolved
PROVE PROPER OPERATION OF AUTOMATIC HALON SYSTEM SHUTDOWN FOR #2 MAIN GENERATOR.
Condition: Unknown
Due 15 May 1998
Resolved 15 May 1998
Engineering
Issued 18 March 1998 Resolved
Conduct suitable repairs to ABS surveyor satisfaction to cracked weld in port side aft fresh water tank.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Construction/Loadline
Issued 25 January 1995 Resolved
SUBMIT PROPOSAL FOR SIDE SHELL REPAIR TO PORT SIDE SIDE, APPROXIMATE FRAME 24.5 THROUGH 26.
Condition: Unknown
Due 25 January 1995
Resolved 25 January 1995
Construction/Loadline
Issued 25 January 1995 Resolved
COMPLETE REPAIRS TO WATERTIGHT BULKHEAD #25 PORT, LOWER SECTION APPROXIMATELY 2 FEET BY 4 FEET; GUSSET #25.5 AND DEEP WEB FRAME #26, LOWER SECTION APPROXIMATELY 2 FEET BY 4 FEET.
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Fire Fighting
Issued 8 June 1994 Resolved
PROVE PROPER OPERATION OF CO2 PRESSURE SWITCH SHUTDOWN FOR #4 GENERATOR. GENERATOR IS NOT TO BE OPERATED UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Electrical
Issued 9 July 1993 Resolved
INSTALL A COVER ON THE DEAD-ENDED ELECTRICAL BOX LOCATED INBOARD OF THE MAIN SWITCHBOARD ON THE FORWARD MACHINERY SPACE BULKHEAD.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Engineering
Issued 9 July 1993 Resolved
REPAIR/REPLACE THE SCREENS ON THE SUPPLY AIR VENTS IN THE MACHINERY SPACE.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Engineering
Issued 9 July 1993 Resolved
CLEAN THE EXHAUST VENT SCREENS IN THE MACHINERY SPACE.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Electrical
Issued 2 July 1992 Resolved
MAKE OPERATIONAL ALL EMERGENCY LIGHTS IN THE CRANE PEDISTALS.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Engineering
Issued 2 July 1992 Resolved
PROVE OPERATION OF THE OILY WATER SEPERATOR.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Fire Fighting
Issued 2 July 1992 Resolved
PROVE OPERATION OF THE FIXED HALON SHUTDOWN FOR NUMBER THREE GENERATOR.
Condition: Unknown
Due 7 July 1992
Resolved 7 July 1992
Lifesaving
Issued 5 July 1991 Resolved
RENEW OR REMOVE FAILED LIFERINGS ON STERN AND AFT STBD QTR. (LIFELINE WEATHERED).
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Construction/Loadline
Issued 5 July 1991 Resolved
RENEW ALL SAFETY CHAINS AS REQUIRED.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Fire Fighting
Issued 5 July 1991 Resolved
RENEW BROKEN GLASS IN BREAK BOX MOUNTED ON FORWARD SIDE OF HALON ROOM.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Construction/Loadline
Issued 5 July 1991 Resolved
MAKE BARGE AVAILABLE FOR INTERNAL STRUCTURAL EXAM.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Engineering
Issued 5 July 1991 Resolved
CLEAN FLAME SCREENS ON DIESEL BREATHER VENTS.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Engineering
Issued 5 July 1991 Resolved
RESTENCIL EMERGENCY SHUTOFF MARKINGS.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Electrical
Issued 5 July 1991 Resolved
PROVE SATISFACTORY OPERATION OF FOC'SLE STORAGE ROOM EMERGENCY LIGHTING.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Electrical
Issued 5 July 1991 Resolved
REPLACE MISSING GLOBES LOCATED IN LADDER WELLS TO FOC'SLE.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Electrical
Issued 5 July 1991 Resolved
REPLACE BROKEN LIGHT GLOBE ON STBD SIDE OF AFT BULKHEAD OF FOC'SLE.
Condition: Unknown
Due 5 July 1991
Resolved 5 July 1991
Electrical
Issued 5 July 1990 Resolved
REPLACE JUNCTION BOX COVER ON TROUBLE LIGHT SYSTEM IN FORWARD STOREROOM
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Electrical
Issued 5 July 1990 Resolved
REMOVE OR PROPERLY END DEADENDED WIRE FOR 700-27 PLC SYSTEM IN FWD STORES.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Engineering
Issued 5 July 1990 Resolved
DEMONSTRATE IN THE PRESENCE OF A MARINE INSPECTOR THE PROPER OPERATION OF VESSEL'S OILY WATER SEPARATOR. UNTIL THIS ITEM IS COMPLIED WITH, VESSEL IS PROHIBITED FROM DISCHARGING MACHINERY SPACE BILGE WATER.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Construction/Loadline
Issued 5 July 1990 Resolved
CROP AND RENEW BUCKLED AREA(APPROX 3'BY1') OF TRANSVERSE VERTICAL SIDE FRAME#76 IN WAY OF SIDE LONG NUMBER 4 STBD SIDE.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Electrical
Issued 5 July 1990 Resolved
INVESTIGATE AND REPAIR CAUSE OF PARTIAL GROUND INDICATION ON TEST PANEL IN FWD STOREROOM
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Electrical
Issued 6 July 1989 Resolved
REMOVE BATTERIES IN RACKS IN ENGINE ROOM AND PROPERLY TERMINATE / REMOVE ELECTRICAL WIRING.
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Fire Fighting
Issued 6 July 1989 Resolved
SUPPLY DOCUMENTATION FOR ALL FIRE EXTINGUISHERS AND FIXED SYSTEM SERVICING.
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Documentation
Issued 6 July 1989 Resolved
SUPPLY CURRENT CARGO GEAR CERTIFICATE.
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Construction/Loadline
Issued 6 July 1989 Resolved
PERMENENTLY AFFIX STATE OF HAWAII INITIALS ON STERN OF VESSEL.
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Unknown
Issued 6 July 1989 Resolved
STENCIL ENGINE ROOM / PUMP ROOM EMERGENCY SCUTTLE.
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.