Records from 1988 to 2025. Most recent: inspection, 24 December 2025.
Inspection history · 120
24 December 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8287358
30 October 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8233234
26 September 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8241819
9 September 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8230082
17 May 2025
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8137958
16 May 2025
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8141860
18 January 2025
Damage Survey · Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8065270
18 January 2025
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8068924
23 August 2024
DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7984818
17 May 2024
Examination of Repairs · Deficiency Check · Drydock Exam · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7914988
1 May 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7905730
2 February 2024
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7859833
26 October 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7815169
19 July 2023
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7746913
26 May 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7696891
2 March 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7644180
31 January 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7629504
30 January 2023
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7628942
15 January 2023
Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7622166
15 January 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7627038
28 September 2022
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7565031
25 May 2022
Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7459048
23 February 2022
MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7400380
9 August 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7281179
18 June 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7229330
10 March 2021
Plan Review "T" Boat · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7154075
14 January 2021
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7207639
24 September 2020
Internal Structural Exam · Administrative Inspection · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7065071
20 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689013
6 November 2018
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6580619
15 August 2018
Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6521916
11 June 2018
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6442063
1 June 2018
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6431139
16 January 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6338286
25 September 2017
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6275197
14 April 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6124275
15 February 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6092455
8 August 2016
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5966151
7 August 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5966315
17 June 2016
MTSA Verification · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5912947
3 September 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3841025
3 April 2009
Internal Structural Exam · Drydock Extension
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3447330
17 October 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3346418
12 June 2007
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2959670
1 May 2007
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2919979
29 March 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2897738
5 June 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2667146
26 May 2006
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2659712
25 May 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2658965
11 May 2006
Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 2646436
22 April 2006
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2632115
6 April 2006
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2618474
14 September 2005
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2530915
8 July 2005
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2420091
8 April 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2333710
28 February 2005
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2300449
7 September 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2188798
6 August 2004
MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2158286
9 June 2004
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2093419
30 March 2004
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2149591
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971050
21 October 2003
Damage Survey · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1933072
20 October 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1932201
8 September 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1909204
20 June 2003
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1823240
21 April 2003
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1779062
14 December 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1720505
24 June 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1637457
6 May 2002
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613709
6 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613826
2 April 2002
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600154
6 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1484607
20 November 2001
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391725
22 October 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077200
17 October 2001
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074369
16 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 160642
16 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 167681
23 August 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071155
30 April 2001
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059970
30 April 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1435162
13 February 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1454894
3 October 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 81320
3 October 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822620
13 June 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1462112
13 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 160672
1 March 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815468
17 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 730346
26 July 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 23101
23 July 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103792
24 June 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1378720
9 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 702736
16 April 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 152998
19 March 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1447921
26 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 171524
3 February 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 59737
3 February 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365033
24 June 1998
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1433352
26 June 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779308
29 May 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1108917
27 June 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244794
2 November 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1380331
29 June 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 881892
27 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 135524
29 June 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826371
1 November 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1414204
8 July 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157433
29 January 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135913
9 July 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941626
8 November 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 938860
19 July 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941044
11 July 1991
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252328
4 October 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900349
6 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917576
14 July 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 903844
5 July 1990
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1215706
21 November 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 910663
21 November 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 911534
18 May 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1349691
17 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1035733
23 June 1988
Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 891023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2025
Resolved
The owner or managing operator shall have tests and inspections of the fixed gas fire extinguishing system in accordance with 46 CFR 115.810(b)(2). Observed service Pipping with visible deterioration and rust STBD Eng compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2025
Resolved 29 April 2026
Resolution: Both port and stbd piping was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 September 2025
Resolved
Vessel is required to carry 50% of IBA when operating in a limited coastwise route in warm waters. One of the vessels IBA's failed to pass annual servicing inspection. Vessel is restricted to carry not more than a 198 passengers until the other IBA has been installed for service. Must notify the USCG marine inspection office once the IBA has been installed. 46 CFR 117.200 (c)(ii) Code 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2025
Resolved 10 October 2025
Resolution: IBA was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests of the operation of the main propulsion machinery both ahead and astern. The vessel's port ME is currently inoperable due to the port ER fire. The vessel must conduct adequate repairs to the satisfaction of the cognizant OCMI prior to carriage of passengers.
46 CFR 115.804(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2025
Resolution: Conducted sea trial and DVTP/QFA on port electronic propulsion control.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of electrical equipment and systems including the inspection of all cable as far as practicable. The fire in port ER has caused damage to multiple electrical equipments and cable insulations. A thorough plan review and repair to the satisfaction of the cognizant OCMI must occur prior to clearance of this deficiency.
46 CFR 115.806(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2025
Resolution: Electrical instalations have been repaired in accordancd with 46 CFR 110 (J) and 46 CFR 120 (K). An Electrical Engineer certified the work with a bill of materials were replaced in kind with approved plans.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2025
Resolved
The owner or managing operator shall have tests and inspections of the fixed gas fire extinguishing system in accordance with 46 CFR 115.810(b)(2). The vessel's Port ER does not have means of fixed fire extinguishing.
46 CFR 115.810(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2025
Resolution: A 3rd contracted fire technician company replaced the used halon cylinder and serviced both port and starboard fixed gas extingushing system, and certified properly working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2024
Resolved
Port fwd bilge suction optest was Unsat. Make necessary repairs and conduct full system optest during topside inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 26 August 2024
Resolution: Conducted a satisfactory test of the bilge pump by emptying one compartment on each side of the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2024
Resolved
Replace corroded coupling on stbd day tank fuel line.
46 CFR 115.804
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 August 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 June 2024
Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detecting system to determine that the system is in operating condition. Wasted fixed firefighting system pull cable conduit, pressure switches in stackhouses. Prior to carriage of passengers, provide service report for the satisfactory condition and performance of the system addressing the satisfactory repairs of the conditions listed above.
46 CFR 115.810
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: A new fire servicing test was issued by a local techiniciand and a new certificate was issued with a passed test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2024
Resolved
Code 11118: An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child-size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided. USCG Marine Inspector found 160 adult size and 1 child size life-jackets with flotation foam material inside severely deteriorated, also, some were found with discoloration and damaged retro-reflective material. 46 CFR 117.71 (a) and (b). Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2024
Resolution: Verified all lifejackets and found 302 adult and 16 child sized lifejackets on board, all compliant with the requirements.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 February 2024
Resolved
Code 02108: Electrical equipment on a vessel must be installed and maintained to: a. provide services necessary for safety under normal and emergency conditions; b. protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; c. minimize accidental personnel contact with energized parts. An electrical outlet was found laying unsecured on the deck, underneath lifejackets in the portside bench number 2, behind operating station, deck 2. 46CFR120.200 (a), (b) & (c). Code 16C.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2024
Resolution: Electrical outlet was eliminated as was no longer in used, deactivating it from the switchboard and cable eliminated from its source.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 February 2024
Resolved
Code 03106: Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. The following water intrusion conditions were found:
1. Multiple windows in both sides, and both main and upper deck were found not maintaining its weathertight condition, allowing water intrusion into main passenger accommodation areas.
2. The panels covering all-around superstructure in between upper and main deck was found to have a gap, allowing water to enter, and being trapped in between decks, also leaking inside the main deck lower passenger accommodation area. 46CFR1020 Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2024
Resolution: All lower port, stbd and frontal windows were resealed, and outside of the bulkwark at the fron and sides in between the two decks was sealed. All were tested with a fire hose and found no water intrusion to the lower main passenger deck.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2024
Resolved
Code 02110: The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. A spray deflector as detailed in DWG 961 12-6F Raft Details is missing in port and starboard sides, and forward, underneath the vessel superstructure that prevents sea water intrusion to the main cabin deck.46 CFR 115.700(d) Code 17C.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2024
Resolution: All repairs have been carried out in accordance with the apprved plan, the spray deflector shield was welded in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 March 2023
Resolved
Exhaust gas must not leak from the piping or any connections. Inspectors found an exhaust leak coming from the port side generator piping within the void aft of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 20 April 2023
Resolution: Attended vessel and verified newly installed lagging. Installed satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2023
Resolved
A vessel must comply with the structural design requirements of one of the standards for aluminum hull vessels.
Make permanent repairs to the following items identified by marine inspectors:
01 hole port side hull- aft outboard near stern.
02 holes port side approximately 6' to 8' forward of undersized insert.
01 hole located at keel bottom approximately 1' fwd of the port sea-strainer guard.
02 previous permanent repairs located on the port side outboard hull and the outboard starboard hull. These repairs appear to be between 10" x 10" and 12" x 12" but less than the minimum 18" x 18" insert.
Remove port sea strainer inlet grating for inspection.
Remove temporary epoxy repair on port side engine room deck forward of the main engine approximately 4" x 5" for re-inspection and make permanent repairs as needed.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2023
Resolved 22 February 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 January 2023
Resolved
A space containing diesel machinery must be fitted with adequate means, such as dripproof ventilator, ducts, or louvers, to provide sufficient air for proper operation of main engines and auxiliary engines.
Starboard E/R air vent louver damaged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2023
Resolved 26 May 2023
Resolution: Received photo of installed stbd e/r air vent louver.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2023
Resolved
A vessel must comply with the structural design requirements of one of the standards for aluminum hull vessels.
a) Identified fuel leaking from the outside of the inboard port hull integral fuel tank. Remove fuel and provide marine chemist certificate prior to USCG fuel tank inspection.
b) Identified discoloration mark on the outside of the inboard starboard hull integral fuel tank. This mark smelled like fuel but no visible fuel leak could be seen. Remove fuel and provide marine chemist certificate prior to USCG fuel tank inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2023
Resolved 22 February 2023
Resolution: Verified repairs were made to bottom plating 6" past the the forward and aft bulkheads of both port and starboard day fuel tanks and approximately 4' upwards from the keel on the inboard and outboard sides of both port and starboard hulls.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2023
Resolved
Observed pitting along the bottom plating of both port and starboard day fuel tanks and located two deep pits .5" in diameter where fuel was observed leaking through the plating. Crop and renew bottom plating 6" past the the forward and aft bulkheads of both port and starboard day fuel tanks and approximately 4' upwards from the keel on the inboard and outboard sides of both port and starboard hulls.
After fuel tank repairs are completed, conduct satisfactory hydrostatic pressure tests in the presence of USCG marine inspectors IAW 46CFR119.435(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2023
Resolved 22 February 2023
Resolution: Observed sat standpipe pressure test on port and starboard fuel tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 January 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel sustained damage to starboard shaft and propeller when departing Ceiba, PR. Length of shaft from propeller to vessel entrance at stern tube is missing. Vessel to remain out of service until dry dock oversight and repairs can be completed by attending marine inspector. Repair proposal and vessel specification of shaft/propeller to be sent to USCG for review. 46 CFR 119.200(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2023
Resolution: Observed satisfactory repairs and conducted satisfactory sea trials. Sea narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. STBD Side engine is not fully operational provided a mechanical report attesting of the operation of the engine to the satisfaction of the attending marine inspector.
46 CFR 119.200 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 23 February 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances.
- Port side fore peak transversal frame num. 1 had 1/2 inch crack. Repair during drydock inspection.
Action required: 705 - Other - as specified
Resolved 17 October 2022
Resolution: Fractured weld was re-welded and corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The vessel experienced a starboard engine failure. Proof of repair and proper operation must be done in the presence of an attending marine inspector prior to normal operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2021
Resolution: Received RPM sensor and installed on port engine.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 April 2021
Resolved
Vessels to which this subchapter applies must meet the applicable provision of subchapter S (Subdivision and Stability. Due to the installation of the baggage corral the number of passengers allowed to be carried is reduced form 257 to 249. This CG-835 is to be posted next to the Certificate of Inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2021
Resolved 28 July 2021
Resolution: Amended COI
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2021
Resolved
Bulkheads and decks must be classed as A-0 as per tables 116.415(b) & Table 116.415 (c). As per the vessel's approved Structural Fire Protection Plan, found missing structural fire protection insulation in the following areas:
a. Under bridge electrical cable runs, are open open to the bridge with three (03) openings.
b. underside of ladder from the wheelhouse deck to flying bridge deck, the insulation had fallen.
c. Port & starboard engine rooms overhead and forward bulkhead. Multiple small areas of insulation had been removed.
d. Port & starboard engine rooms electrical cable penetrations were open.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 20 April 2021
Resolution: The missing areas of Structual Fire Protection was installed using 164.007 approved insulation 1-3/4 inch thickness of 8 pound density.Orginal insutlation 2-inch thichnesse of 8 pound density.ASTM-E814 fire stop used on cable openings. See attached
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2021
Resolved
At each inspection, the bilge may be examined to see there is no excess accumulation of debris that might clog the bilge pumping system. Metal shavings and rust was found in port & starboard engine room bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 20 April 2021
Resolution: Upon arrival for def check found there were still items in the bilge. All items were removed while onboard.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 22 March 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary under normal and emergency conditions. The heat detector in the starboard engine room aft, the securing device was wasted and the detector was hanging by its cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 28 July 2021
Resolution: Received photo of heat detector mounded to the overhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2021
Resolved
Replace two missing Type I, USCG approved child size life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 1 April 2021
Resolution: Two life jackets have been placed on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 March 2021
Resolved
Provide a Senior Deckhand Letter of Designation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 1 April 2021
Resolution: Senior Deckhand letter of designation was presented and placed on board.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 March 2021
Resolved
Post a VHF Radio Emergency Broadcasting Placard next to the VHF radio at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 7 April 2021
Resolution: Placard Installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2021
Resolved
Vessel must carry an USCG approved first aid kit. 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 20 April 2021
Resolution: New first aid kit onboard meeting 160.041; marked with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 March 2021
Resolved
Arrangements must be made to the ring buoy water light line to be attached to the life ring with a corrosion resistant clip, and around to the body of two life rings. 46 CFR 180.30-10.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 20 April 2021
Resolution: Corrosive resistance clip installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 March 2021
Resolved
Provide updated publication on board such as: nautical charts, tide & current tables, light list, coast pilot and COLREGS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 20 April 2021
Resolution: Current nautical charts, tide & current tables, light list, coast pilot and COLREGS; all marked with vessel name.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 10 March 2021
Resolved
Provide the Marine Safety Center all required information of removal of existing AC units and installation of the new ones, in order to update any changes to the stability letter issued by MSC.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 10 June 2021
Resolution: Breezy Point Generator Load Capacity Certification dated April 22, 2021. Reviewed at Sector San Juan.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021
Resolved
Properly secure all electrical wiring and connections in all newly installed AC units.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 20 April 2021
Resolution: All cable were bundled and secured to overhead with metal clips.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 March 2021
Resolved
Provide all required information for company Employee Assistance Program and make it available to all employees.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 7 April 2021
Resolution: Posted on brige and aft bulkhead of wheel house deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2021
Resolved
Provide a DOT approved alcohol testing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 20 April 2021
Resolution: DOT approved alcohol testing strips provided, box marked with vessel name.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2021
Resolved
Provide additional day shapes: one diamond and one ball. COLREGS
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 1 April 2021
Resolution: Requested day shapes have been placed on board.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 March 2021
Resolved
Proof proper operation of 3 battery operated lanterns.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 1 April 2021
Resolution: Lanterns were found fully operations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 March 2021
Resolved
Main deck forward access hatch must be weathertight and replace broken tag. 46 CFR 116.1160 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 20 April 2021
Resolution: Two (02) of four (04) securing devices replaced. All four (04) wedges installed. Door is now weather tight.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 March 2021
Resolved
Replace PFD donning placard to show the existing PDF model currently on board. 46 CFR 122.516.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 7 April 2021
Resolution: Correct placards are installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 March 2021
Resolved
Post approved egress emergency plan and make it accessible to passengers in all decks. 46 CFR 177.05-3.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 28 July 2021
Resolution: Received photo showing the Emergency Egress Plan was posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 March 2021
Resolved
Emergency instructions must be updated. 46 CFR 185.25-5.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 7 April 2021
Resolution: Updated
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2021
Resolved
Stbdside exhaust pipe lagging must be re-installed and
secured.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 20 April 2021
Resolution: Exhaust pipe lagging re-installed and properly secured.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 March 2021
Resolved
Port & Stbd side engine room access hatches are not airtight; missing segments of rubber gaskets and door tags must operate properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 28 July 2021
Resolution: Received photos showing gaskets for the port and starboard engine room hatches have been replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 March 2021
Resolved
Several deck hatches door rubber gaskets are not sealing properly, allowing water ingress to various compartments, specially the stbdside steering room. 46 CFR 116.1160
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 21 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 March 2021
Resolved
Portside rudder angle gear is disconnected from steering actuator box. 46 CFR 176.25-35. DUE 07APRIL2021.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 22 April 2021
Resolution: Arm welded and properly connected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2021
Resolved
Repair sharp edge located on a bench seat at the exterior, back of second deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 20 April 2021
Resolution: Seat edge was repaired and expoxy coated.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 March 2021
Resolved
Repair stbdside fire pump as it was found leaking. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 20 April 2021
Resolution: Flange on pump was tightened, pump tested, no leaks observed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 March 2021
Resolved
Stbdside VHF antenna cable has exposed wiring on deck above the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2021
Resolution: New antenna installed, satisfactory radio test complete with atm ferry in Vieques, PR
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2021
Resolved
Portside engine room 12V distribution panel is missing its cover door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 28 July 2021
Resolution: Received photo of cover installed
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 10 March 2021
Resolved
Bull horn on upper deck has exposed dead end wires and not to be connected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 7 April 2021
Resolution: Bullhorn was connected with approved type connectors.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 March 2021
Resolved
The following areas have missing or compromised thermal/heat insulation:
a. Port & Stbdside engine room access surrounding bulkheads and stairways leading to the second deck;
b. underneath stairways leading to the 3rd deck;
c. overhead of the existing cold room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 7 April 2021
Resolution: After recieving the structual fire protection plans reissued as deficiency number 40.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 March 2021
Resolved
Provide copy of the approved structural fire protection plan. 46 CFR 177.05-3. DUE 07APRIL2021.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 7 April 2021
Resolution: Structural Fire Protection Plans have been received by SSJ.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2021
Resolved
Replace border seals around new A/C units and insulation above overhead tiles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 7 April 2021
Resolution: Border seals have been installed back.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 March 2021
Resolved
Conduct testing of all heat detectors in presence of an USCG Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 26 March 2021
Resolution: An annual fire testing service report declared that the heat detection system was recently tested and found operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2021
Resolved
Test emergency fuel shut-off valves in presence of an USCG Marine Inspector. 46 CFR 185.30-20.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 26 March 2021
Resolution: Fuel shut-off safety valves were tested in presence of an attending USCG Marine Inspector and found to be operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2021
Resolved
Submit electrical load analysis to MSC for new A/C installations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 28 July 2021
Resolution: Received and review load alnaysis dated 22Apr2021, reviewed by [name withheld], MMI, Sector San Juan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2021
Resolved
Stuffing boxes on both port & stbd engine rooms access must be sealed with approved fire retardant sealer (electrical stuffing boxes)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 7 April 2021
Resolution: Reissued Item #40, port and starboard electrical penitrations were only partially closed using ASTM E-814 sealant.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 March 2021
Resolved
Portside fire pump pressure gauge was found inoperable. 46 CFR 176.25-50.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2021
Resolved 20 April 2021
Resolution: New pressure guage installed, test ran pump, pressure guage working.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021
Resolved
Ensure all PDF storage locations displays accurate count of PDFs within that storage. 46 CFR 185.30-10.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 28 July 2021
Resolution: Received e-mail that all signs have been updated - to be verified at future in-service. Previously stowage area signage did not meet the letter height requirements but were marked.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 March 2021
Resolved
Provide copy of the approved structural fire protection plan of the engine rooms. 46 CFR 177.05-3. DUE 07APRIL2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 7 April 2021
Resolution: Structural Fire Protection Plan was received by SSJ.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 March 2021
Resolved
Re-position EPIRB to a location more accessible to be retrieved in case of emergency and fin a float free position. 46 CFR 177.64.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 7 April 2021
Resolution: EPIRB was re-positioned to stern of the main deck a more accessible area to be reached by the crew in case of an emergency.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 March 2021
Resolved
Log monthly testing of the EPIRB. 46 CFR 185.25-20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 20 April 2021
Resolution: New log established with vessel name, EPIRB testing for March and April was logged.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 March 2021
Resolved
Suitable means such as an automatic damper must be provided for shutting off the passage of air through the ventilation duct in the event of a fire. Found the damper mechanism for the starboard engine room would not completely reset leaving one side closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 28 July 2021
Resolution: Received photo fire damper properly reset.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2021
Resolved
In the presence of a Marine Inspector complete the testing of the Propulsion Control Qualitative Failure Analysis (QFA) and Design Verification and Periodic Test(DVTP) procedures per MSC Plan review letter E2-2100376 dated February 17, 2021. Provide all references listed in the letter prior to conducting the testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2021
Resolved 10 June 2021
Resolution: Testing was competed by Sector New York but not entered into MISLE. Sector New York Inspector to update MISLE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2018
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel was hauled out at North River Shipyard with the intent to conduct repairs without notifying the cognizant OCMI. Vessel must submit proposal for engine repairs prior to conducting work.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2018
Resolution: Visually inspected final weld and witnessed satisfactory vacuum test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2018
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is underataken. Vessel must conduct sea trials once repair work is complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2018
Resolution: witnessed sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 June 2018
Resolved
Repair fire alarm system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: Fire alarm system was serviced and found in operational condition.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2018
Resolved
- Replace CO2 fire extinguishers in accommodation spaces with foam or dry chemical extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: CO2 extinguishers were replaced with dry chemical extinguishers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2018
Resolved
Replace blank on distribution panel, 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: A new blank was installed on the electrical panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2018
Resolved
Replace 07 child life jackets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2018
Resolution: Replacement lifejackets were purchased and placed into service.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 June 2018
Resolved
Repair structural fire protection in 2nd deck electrical space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: The structural fire protection was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 1 June 2018
Resolved
Repair/remove bench stand (tripping hazard), aft second deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2018
Resolution: Bench was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2018
Resolved
Repair exposed wiring in void #2, port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: The exposed wires were connected and placed inside of a junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2018
Resolved
Re-attach wiring mounts in void #2, starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: The wiring mounts were re-attached.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 September 2017
Resolved
Port side ventilation closure for the ER was inoperable. Repair prior to carrying PAX.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2017
Resolution: Verified operation of ventilation system.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 25 September 2017
Resolved
Hydrostatic releases on IBAs were not installed properly. Vsl restricted to no more than 1 NM from shore until corrected.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 27 September 2017
Resolution: Verified correct installation of IBA hydrostatic releases.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 September 2017
Resolved
Replace chaffed wiring and secure wire runs for port and starboard spotlights.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 27 September 2017
Construction/Loadline › Penetrations › Gasket
Issued 25 September 2017
Resolved
Repair port aft void watertight hatch and gasket.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 27 September 2017
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 25 September 2017
Resolved
Replace or test port and starboard Halon system discharge hoses.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 5 October 2017
Resolution: New, approved hoses were installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 25 September 2017
Resolved
Secure sewage overboard.
Action required: 705 - Other - as specified
Resolved 25 September 2017
Resolution: Handles were removed
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 14 April 2017
Resolved
ALL OF THE VESSEL'S INFLATABLE BUOYANT APPARATUS HAVE BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL IS LIMITED TO A LAKES, BAYS, AND SOUNDS ROUTE NOT MORE THAN ONE NAUTICAL MILE FROM SHORE UNTIL THE IBA'S HAVE BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 8 June 2017
Resolution: Verified installation of inflatable liferaft.
Engineering › Fuel Oil Service System › Valve
Issued 15 February 2017
Resolved
Install manual fuel shutoff valves for the port and stbd fuel lines near the fwd fuel tanks.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 24 March 2017
Resolution: Vessel rep. installed manual fuel shut off valves on both port and stbd lines.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 8 August 2016
Resolved
Prove porper operation of propulsion machinery.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 August 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 June 2016
Resolved
There was a hydraulic leak in the stbd steering system. Repair.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Resolution: Leak repaired.
Fire Fighting › Fire Pumps › Pressure
Issued 24 June 2016
Resolved
Fire pump gauges were inoperable. Repair/replace.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Fire Fighting › Fire Pumps › Gland Sealing
Issued 24 June 2016
Resolved
Gasket on stbd fire system sea chest was leaking. Replace.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 June 2016
Resolved
There was an exhaust leak in the port laz. Repair.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Engineering › Bilge Water Management System › Hose
Issued 24 June 2016
Resolved
Replace p/s E/R bilge suction hose with approved piping/hoses.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 24 June 2016
Resolved
Identified eight (08) cracked welds in the aft compartments. Repair.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 11 July 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2008
Resolved
The vessel must complete an annual exam prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2016
Resolution: Conducted COI Renew Inspection
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2007
Resolved
Replace the raw water cooling bellows on the stbd engine, discharge side.
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 20 July 2007
Resolution: Witnessed the satisfactory replacement of the raw water cooling bellows on the stbd engine, discharge side.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 June 2007
Resolved
Repair the port and stbd remote fuel shut off valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2007
Resolved 20 July 2007
Resolution: The port and stbd remote fuel shutoff valves were tested satisfactory.
Communications › Radio Communications › EPIRB
Issued 12 June 2007
Resolved
Replace the EPIRB battery, old battery is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2007
Resolved 20 July 2007
Resolution: EPIRB battery was replaced and working properly.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 June 2007
Resolved
Properly label all emergency escapes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2007
Resolved 20 July 2007
Resolution: All emergency escapes were properly labeled.
Documentation › Certificates/Documents › FCC SSL
Issued 12 June 2007
Resolved
Provide the vessel with a Bridge to Bridge certificate.
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 20 July 2007
Resolution: The vessel was provided with a Bridge to Bridge Certificate.
Fire Fighting › Fire Pumps › Capacity
Issued 5 June 2006
Resolved
Prior to the carriage of passengers, prove that both PORT and STBD fire pump can produce 60 PSI at the pump dischage. Could only produce 30 psi on the STBD and 40 psi on the PORT.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2006
Resolved 12 June 2007
Resolution: Satisfactorily tested the proper operation of both port and stbd fire pumps.
Engineering › Bilge Water Management System › Piping
Issued 5 June 2006
Resolved
Prior to the carriage of passengers, remove all soft patches on all vital systems as discussed. Found several areas that the pipe was either repaired or coupled with a rubber hose w/hose clamps. All piping is aluminum.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2006
Resolved 12 June 2007
Resolution: Verified the satisfactory condition of all vital system piping.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 5 June 2006
Resolved
Prior to the carriage of passengers, repair/replace missing insulation in PORT engine room. A sizable piece of insulation was missing from BLKHD in the PORT engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2006
Resolved 12 June 2007
Resolution: Piece of insulation was properly placed in port engine room.
Construction/Loadline › Hull › Hull Plating
Issued 30 May 2006
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, EFFECT REPAIRS TO THE TRANSOM OF THE STARBOARD HULL AND THE DECK RAIL/SWIM PLATFORM ABOVE THE STARBOARD HULL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2006
Resolution: INSPECTED AND DIE-PEN WELDS, ALL SAT.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 22 April 2006
Resolved
Vessel lost (1) inflatable life raft on voyage from New York to Florida. Prior to carrying passengers, vessel must provide adequate lifesaving equipment IAW COI.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2006
Resolved 5 June 2006
Resolution: VSL IS ONLY REQIRED TO CARRY 50% OF LIFE SAVING CAPABILITY VIA LIFE RAFTS IN WARM WATER AS PER 46CFR TABLE 117.200(c).
Fire Fighting › Fire Main › Condition
Issued 6 April 2006
Resolved
Firemain in stbd engine room wasted through IWO "T" on overhead. Make proper repairs to the satisfaction of the attending Marine Inspector prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 17 April 2006
Resolution: Pipe section was fabricated by shipbuilder, installed & tested sat.
Electrical › Electric Generation Source (service) › Generator
Issued 6 April 2006
Resolved
Prove proper operation of stbd ship service generator prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 17 April 2006
Resolution: Genset tested under load - sat.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 April 2006
Resolved
Portside bilge system failed to operate. Prove proper operation of bilge system prior to carrying pasengers for hire.
Action required: 705 - Other - as specified
Resolved 17 April 2006
Resolution: Bilge system tested taking suction from forepeak compt.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 21 October 2003
Resolved
All Halon to Stbd Engine Room discharged. Fire fighting capability must be restored and certified by competent servicing company. LEGACY COMPONENT DESC: Quantity of Halon
Due 20 November 2003
Resolved 3 November 2003
Resolution: New halon bottles installed and halon fire extinguishing piping as satisfactorily hydro tested to 150 psi with no loss in pressure.
Electrical › Electrical Distribution System (service)
Issued 21 October 2003
Resolved
Fire damaged electrical components to be repaired. Thermo couples to stbd MDE turbo/exhaust to be replaced. Plastic covers to light fixtures melted by fire to be replaced.
Due 20 November 2003
Resolved 3 November 2003
Resolution: Stbd MDE replaced in kind. Plastic light covers replaced.
Fire Fighting › Fixed Fire Detection System
Issued 21 October 2003
Resolved
Destroyed Fire Detection above MDE to be repaired.
Due 20 November 2003
Resolved 3 November 2003
Resolution: Fire detection reinstalled and tested.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 October 2003
Resolved
Turbo charger (Inboard/A-bank) to be repaired along w/ exhaust elbow and heat shield.
Due 20 November 2003
Resolved 3 November 2003
Resolution: Stbd engine completely replaced in kind.
Engineering › Freshwater System (jacketwater cooling)
Issued 21 October 2003
Resolved
Make repairs to damaged cooling system, incl. leaking hose at fwd of engine connecting water pump to engine block.
Due 20 November 2003
Resolved 3 November 2003
Resolution: Stbd engine completely replaced in kind.
Pollution Prevention/Response
Issued 21 October 2003
Resolved
Remove all oil from engine room bulkheads, bilge, engine exterior, and overhead. Fire and pollution hazard.
Due 20 November 2003
Resolved 3 November 2003
Resolution: All oil removed from bilge.
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 21 October 2003
Resolved
Missing 2" cleanout pipe at terminating orifice over both MDE's.
Due 10 November 2003
Resolved 7 November 2003
Resolution: Cleanouts installed.
Accommodation/Occupational Safety
Issued 24 June 2002
Resolved
Permanently secure cash register and loose gear under bridge
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Electrical › Lighting (service)
Issued 24 June 2002
Resolved
Identlify and repair leak in bridge spotlight.
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Documentation › Logs/Records
Issued 24 June 2002
Resolved
Provide proof of lifesaving drill and inplementation of record book.
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Documentation
Issued 24 June 2002
Resolved
Provide proof DAPI program participation.
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Engineering › Bilge Water Management System
Issued 24 June 2002
Resolved
Replace inop engineroom bilge water high indicator light on bridge.
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Construction/Loadline › Hull
Issued 24 June 2002
Resolved
V-weld cracked weld in forepeak as marked.
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Electrical › Electrical Distribution System (service)
Issued 24 June 2002
Resolved
Install Drip shield over battery charger in port engineroom.
Due 23 August 2002
Resolved 5 May 2003
Resolution: Administratively cleared.
Construction/Loadline
Issued 17 October 2001
Resolved
MAKE REPAIRS TO DAMAGED AREA OF STARBOARD BOW TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Engineering
Issued 17 October 2001
Resolved
CONDUCT SEA TRIAL IN THE PRESENCE OF THE ATTENDING MARINE INSPECTOR TO PROVE PROPER OPERATION OF THE PROPULSION PLANT.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Fire Fighting
Issued 23 August 2001
Resolved
INSTALL CLOSING LATCHES FOR SMOKE DOORS
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Construction/Loadline
Issued 23 August 2001
Resolved
DRILL STOP, V & WELD AND DYE PEN TEST "Y" CRACK IN PORT INBOARD TRANSOM VOID BULKHEAD, AT UPPER OUTBOARD SIDE.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Fire Fighting
Issued 23 August 2001
Resolved
PROVIDE FIE CONTROL PLAN IN ACCORDANCE WITH 46 CFR 116.530.
Condition: Unknown
Due 21 September 2001
Resolved 5 May 2003
Resolution: Administratively cleared.
Construction/Loadline
Issued 23 August 2001
Resolved
PROPERLY SEAL STBD FANBOX AT DECK, MAKE WATERTIGHT.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Construction/Loadline
Issued 23 August 2001
Resolved
V & WELD CATWALK PORT STANCHION MOUNT AT DECK
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Construction/Loadline
Issued 23 August 2001
Resolved
V & WELD BURN THROUGH AT SHEAR IN COMPT PORT #2 IN WAY OF OPPOSING DECK MOUNT BRACKETS.
Condition: Unknown
Due 21 September 2001
Resolved 5 May 2003
Resolution: Administratively cleared.
Electrical
Issued 23 August 2001
Resolved
REPLACE PORT A/C LOCAL SWITCH BOX COVER.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Construction/Loadline
Issued 30 April 2001
Resolved
COMPLETE AS BUILT VERIFICATION FOR NEW INSTALLATION OF DRY EXHAUST SYSTEM, MODIFICATION TO FUEL TANK CUT OFF VALVES, AND MODIFICATION TO E/R BLOWERS.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Electrical
Issued 30 April 2001
Resolved
PROPERLY INSTALL METAL WIRE-RUN HANGERS INSIDE ENGINE ROOM ACCESS COMPARTMENTS, PORT & STBD SIDES.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Accommodation/Occupational Safety
Issued 3 October 2000
Resolved
Make permanent repairs to 3 broken windows (stbd side), associated framing and exterior handrail. Vessel may operate with passengers as long as temporary shielding (interior) is in place and adjacent seating is prohibited from passenger use.
Condition: Unknown
Due 3 October 2000
Resolved 3 October 2000
Construction/Loadline
Issued 24 June 1999
Resolved
Pickup welds where burned through in overhead in void #2 on stbd side.
Condition: Unknown
Due 24 July 1999
Resolved 23 July 1999
Construction/Loadline
Issued 24 June 1999
Resolved
MOUNTS THAT ATTACH SUPERSTRUCTURE TO HULL SHOW SIGNS OF FATIGUE AND FRACTURES. SUBMIT REPAIR PLAN FOR MOUNTS THROUGHOUT VSL. INCLUDE PLAN_x001C_ DIAGRAM WITH LABELING OF EACH MOUNT, PRESENT CONDITION AND PAST REPAIRS. MAKE REPAIR TO MOUNTS IN LAZERETS NLT 23AUG99 AND SUBMIT PLAN NLT 30JUL99
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 24 June 1999
Resolved
Drill stop, V & weld the 3 inch crack in deck visible in overhead in port lazerette in way of deck mounts.
Condition: Unknown
Due 24 July 1999
Resolved 23 July 1999
Engineering
Issued 24 June 1999
Resolved
Service fuel injector connections to stbd engine.
Condition: Unknown
Due 24 July 1999
Resolved 23 July 1999
Lifesaving
Issued 24 June 1999
Resolved
Renew Hydrostatic release for EPIRB.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Navigation
Issued 24 June 1999
Resolved
Raise anchor light to position as to be visable 360 degrees in accordance with Nav Rules._x001C_ _x001C_ Light is obscured aft by radar tower.
Condition: Unknown
Due 24 July 1999
Resolved 23 July 1999
Construction/Loadline
Issued 24 June 1998
Resolved
V/W cracked port aft bulwark IWO deck.
Condition: Unknown
Due 1 July 1998
Resolved 10 July 1998
Construction/Loadline
Issued 24 June 1998
Resolved
Submit repair proposal for crack in port hull, inboard void #1 as indicated. Conduct no repairs until proposal is approved by OCMI.
Condition: Unknown
Due 1 July 1998
Resolved 10 July 1998
Fire Fighting
Issued 11 July 1991
Resolved
PROVIDE ONE (1) PORTABLE FIRE EXTINGUISHER TYPE:B SIZE II._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Documentation
Issued 14 July 1990
Resolved
PLACE VALID CERTIFICATE OF DOCUMENTATION ON BOARD VESSEL PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 July 1990
Resolved 14 July 1990
Documentation
Issued 14 July 1990
Resolved
PROVIDE AND POST AN EMERGENCY CHECK-OFF LIST PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 July 1990
Resolved 14 July 1990
Documentation
Issued 14 July 1990
Resolved
PROVIDE AND POST PERMANENT STABILITY LETTER. VESSEL IS LIMITED TO 260 PASSENGERS ON BASIS OF TEMPORARY STABILITY LETTER ISSUED BY MSC 13JUL90.
Condition: Unknown
Due 14 July 1990
Resolved 14 July 1990
Navigation
Issued 17 May 1989
Resolved
PROVIDE PRESSURE VESSEL FOR VESSEL'S WHISTLE THAT MEETS THE REQUIREMENTS OF 46-CFR 54.01-5 (C) (4)
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
PORT AND STBD FIRE/BILGE PUMP MISSING GAUGE. PROVIDE GAUGE ON THE DIS- CHARGE SIDE OF PUMP IN ACCORDANCE WITH 46CFR 181.10(C).
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989