Records from 2016 to 2023. Most recent: inspection, 9 October 2023.
Inspection history · 5
9 October 2023
COC-CVE Annual · PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7804817
19 February 2019
Deficiency Check · COC-CVE Initial · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6626767
15 February 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6626757
29 November 2016
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6047272
29 April 2016
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5865694
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 February 2019
Resolved
Fire doors in main vertical bulkheads and stairway enclosures shall be capable of self closing and the speed of closure shall, if necessary, be controlled so as to prevent undue danger to persons. Found the following fire doors not properly closing: Z3-2-421, Z2-5-403, Z2-5-406, Z3-6-417, Z3-6-414, Z2-5-402, Z1-5-401, Z1-6-405, 8-411, 8-601, *Z3A-4-441, *Z3A-4-440. (* - Sliding Mechanism not re-opening properly).
(74) SOLS 81 Amm. Ch II-2/Reg 30.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2019
Resolved 20 February 2019
Resolution: Doors were adjusted by vessel maintenance and checked by USCG Inspector.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 19 February 2019
Resolved
Discharges overboard of bilge water which has accumulated in the machinery spaces shall be completed on each occasion, on a tank-to-tank basis. Operations involving the bilge water holding tank to the OWS to the clean bilge water holding tank and from this tank overboard have incorrect entry codes. Correct entry codes and provide training/direction to engineering officers.
MARPOL 73/78 (2011 Cons Ed) Annex I Reg 17.2.4
Action required: 10 - Deficiency Rectified
Due 19 February 2019
Resolved 19 February 2019
Resolution: Corrected entry codes and provided training/direction to engineering officers.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 November 2016
Resolved
1410 - After any survey of the ship has been completed, no change shall be made in the machinery equipment covered by the survey. The lagging on both marine diesel engines manifold is not properly installed. - SOLAS 74/78 I/11 -16a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 1 December 2016
Resolution: Received class attestation as to the proper installation of lagging.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 29 November 2016
Resolved
0715 - Indicating units shall denote the section in which a detector has operated. Heat detector B-1-008 does not activate indicating unit on the bridge. -SOLAS 74 II-2/13.1.6 -10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2016
Resolved 29 November 2016
Resolution: Vessel rectified deficiency while MSD St. Thomas and the Class Society was onboard during COC-CVE-Annual exam.
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 29 November 2016
Resolved
0725 - Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO witnessed discharge of nitrogen bottles for ship's transitional power supply for the wet type automatic sprinkler system. SOLAS 74 II-2/21 -17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2016
Resolved 1 December 2016
Resolution: Flag administration and RO authorized a contingency plan to allow vessel to transit to San Juan for attendence by manufacturer's technician. Received class attestation as to proper operation on 01DEC2016.