MAURY USCG vessel records Sign in
← All vessels

C.R. LUIGS

C.R. LUIGS is a 1998 mobile offshore drilling unit. The Coast Guard has recorded 27 inspections since 2000, most recently in August 2014, along with 16 deficiencies.

Records from 2000 to 2014. Most recent: inspection, 19 August 2014.

Built
1998
Last inspected
19 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9189835 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP9764
Flag
VANUATU
—
Maury page id
psix-3205

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (2000–2014)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it47079 - Regulatory (Subpart C or D), Gross Ton
14123 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMBER Offshore Supply Vessel · MISLE 655607 · 19 August 2014 · activity 4960741

Inspection history · 27

19 August 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4960741
9 June 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4341155
21 May 2012 ISPS II Exam · COC-MODU Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4311430
11 June 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3240386
12 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2961325
14 June 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2679945
8 July 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2422765
9 June 2005 COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2385135
21 June 2004 COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2106147
20 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760019
14 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718989
1 July 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646940
15 May 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1617020
20 April 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607027
20 April 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607029
13 March 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1907761
26 January 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481585
17 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 771963
26 September 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074833
29 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070074
23 July 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406994
29 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 771067
20 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195418
16 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820495
28 April 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 56539
24 April 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817086
11 April 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399357

Deficiency record · 16

Lifesaving › Lifeboat › Hull
Issued 21 May 2012 Resolved
Repair the fiberglass damage to the Port Fwd #1 & Stbd Fwd #4 lifeboats to original manufacturer's specs.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 5 June 2012
Resolution: Repaired by Fassmer Techs on 5 Jun 12.
Lifesaving › Launching Appliances › Lines
Issued 21 May 2012 Resolved
Replace the key ring on lifeboat gripesd with a load rated ring.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 9 June 2012
Resolution: Replaced with certified stainless steel shackles.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 21 May 2012 Resolved
Low air pressure on L/B #2 & 4, refill to recommended pressure.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 21 June 2012
Resolution: Bottles refilled on board the vessel on 21 May 12.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 21 May 2012 Resolved
Repair air leak on #4 Lifeboat regulator.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 21 May 2012
Resolution: Air leak was corrected.
Lifesaving › Launching Appliances › Falls
Issued 21 May 2012 Resolved
Provide documentation on the replacement of fall cables and weight testing of davit.
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 18 June 2012
Resolution: Fall cables replaced and weight test conducted by Fassmer and witnessed by ABS.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 21 May 2012 Resolved
Provide testing of reverse power relay testing prior to next rig move.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 21 May 2013
Resolution: ABS tested generator and found them to be within compliance
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 21 May 2012 Resolved
Provide testing of a black start testing of E-Gen prior to next rig move.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 21 May 2013
Resolution: ABS tested generator and found them to be within compliance
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2002 Resolved
Provide obstruction lights per 33CFR Part 67, as referenced in 33 CFR 143.15 (a)
Condition: Unknown
Due 1 August 2002
Resolved 4 January 2004
Resolution: OBSTRUCTION LIGHTS HAVE BEEN INSTALLED ON DRILL SHIP.
Unknown
Issued 23 July 2001 Resolved
PRIOR TO DRILLING OPERATIONS, PROVE POSITIVE VENTILATION IN MUD PIT ROOM, PROVE OPERATION OF LOSS OF VENTILATION ALARM ON BRIDGE, AND ENSURE ALL DOORS IN MUD PIT ROOM ARE SELF-CLOSING.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Unknown
Issued 23 July 2001 Resolved
PROVIDE CG DOCUMENTATION OF APPROVAL FOR FIBERGLASS GRATING IN MUD PUMP ROOM.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Lifesaving
Issued 11 April 2000 Resolved
RECONFIGURE WEIGHT MECHANISM FOR LIFEBOAT QUICK RELEASE ON ALL LIFEBOATS.
Condition: Unknown
Due 24 April 2000
Resolved 3 May 2000
Lifesaving
Issued 11 April 2000 Resolved
PROVIDE TRAINING MATERIAL IN ACCORDANCE WITH 46 CFR 109.213 AND IMPLEMENT FIRE-FIGHTING/LIFESAVING APPLIANCE TRAINING FOR REGULARLY ASSIGNED CREW ANDINDUSTRIAL HANDS EVERY TWO MONTHS.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 11 April 2000 Resolved
LABEL GENERAL ALARM SPEAKERS THROUGHOUT AS NECESSARY, "WHEN ALARM SOUNDS, GO TO YOUR STATION." LABEL ROTATING LIGHTS IN SIMILAR FASHION.
Condition: Unknown
Due 24 April 2000
Resolved 3 May 2000
Electrical
Issued 11 April 2000 Resolved
COMPLETE ALL ELECTRICAL INSTALLATIONS AND WIRING IN MUD CONDITIONING SPACE TO THE SATISFACTION OF ATTENDING CLASS SURVEYOR PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Documentation
Issued 11 April 2000 Resolved
PROVIDE FINAL USCG APPROVAL ON CITIZENSHIP EXEMPTION FOR CREW.
Condition: Unknown
Due 11 April 2000
Resolved 3 May 2000
Construction/Loadline
Issued 11 April 2000 Resolved
COMPLETE ABS SURVEY REQUIREMENTS ISSUED ON 10MAR00 (REFERENCE H&W 1739- P37187).
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000

Ownership record