LANDON JAMES

LANDON JAMES is a 1988 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1988, most recently in October 2023, along with 63 deficiencies and 2 casualty investigations between 2019 and 2022.

Records from 1988 to 2023. Most recent: inspection, 13 October 2023.

Built
1988
Last inspected
13 October 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD4508
321436
Flag
UNITED STATES
367145620
Maury page id
psix-321436

Inspections, by type

…with no type recorded10
Years with a record 32 calendar years (1988–2023)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD4508MMSI 367145620 · active · compulsorily equipped · granted 5 October 2016, expires 17 October 2026
WDC2996MMSI 338251000 · cancelled · compulsorily equipped · granted 15 December 2004, cancelled 27 October 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCV5671MMSI 366749000 · cancelled · compulsorily equipped · granted 29 October 1998, cancelled 18 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PETITE Offshore Supply Vessel · MISLE 220697 · 16 August 2000 · activity 130548MR WALTER Passenger Barge (Uninspected) · MISLE 46319 · 26 July 1998 · activity 44233

Inspection history · 54

13 October 2023 Internal Structural Exam · COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7807897
22 November 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7598320
26 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385820
16 January 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7381179
16 January 2022 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7382286
16 January 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7426011
15 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7351447
14 January 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7124724
11 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110293
14 November 2019 Administrative Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6855380
6 August 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7057648
5 November 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6573468
20 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6291834
10 October 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6284629
9 January 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6068315
15 October 2015 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5743419
13 October 2015 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5741671
23 October 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5017188
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200283
11 February 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3942954
9 December 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3646757
1 December 2008 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3368310
3 December 2007 Examination of Repairs · Deficiency Check · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3108941
28 February 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2882104
30 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2664894
14 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2664154
7 December 2005 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2547145
5 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327036
2 February 2005 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2285523
8 November 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2236982
25 November 2003 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1954051
17 June 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1632194
10 July 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473150
16 August 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 130548
7 June 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441680
14 June 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415196
26 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 44233
26 May 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378374
30 July 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380963
20 June 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457364
29 August 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414504
18 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 72544
15 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176577
6 October 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1172128
27 September 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370922
17 June 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432818
5 October 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359653
7 October 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408912
30 September 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 124900
12 May 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472297
22 November 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252355
30 November 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901492
8 December 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231390
9 December 1988 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196227

Deficiency record · 63

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2023 Resolved
Air-cooled propulsion and auxiliary diesel engines installed below deck, as permitted by § 182.420, must be fitted with air supply ducts or piping from the weather deck. The ducts or piping must be so arranged and supported to be capable of safely sustaining stresses induced by weight and engine vibration and to minimize transfer of vibration to the supporting structure. Support bracket for port side generator observed to be disconnected.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 24 October 2023
Resolution: Received evidence of SAT repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2023 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Monthly EPIRB tests not documented.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 October 2023
Resolved 24 October 2023
Resolution: Conducted training with crew.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel to submit plans for installation within 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 30 January 2024
Resolution: Interconnected detection system installed and tested.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 October 2023 Resolved
All accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks are ready for inspection. Rudder room, aft port corner, beams are warped and should be straighten out. Re-weld cracked welds and welds that were no fully penetrated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 16 October 2023
Resolution: All beams straightened out and rewelded to satisfaction of marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 October 2023 Resolved
Bilge pipe piercing with the collision bulkhead must be fitted with screw down valve located on the fwd side of the collision bulkhead. Forepeak reach rod handle is sheared off and no longer connected to valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2023
Resolved 16 October 2023
Resolution: Handle reattached to reach rod to satisfaction of marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 October 2023 Resolved
All accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks are ready for inspection. Forepeak, fwd void, contains a cracked weld on the port side, near cylindrical support.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 16 October 2023
Resolution: Rewelded to satisfaction of marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 October 2023 Resolved
A bilge suction must be fitted with a suitable strainer. Below the passenger space, starboard side bilge pick up is missing the strainer.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 16 October 2023
Resolution: Strainer attached to bilge pick up to satisfaction of marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2023 Resolved
Fuel shutoff valves, installed so as to close against the fuel flow to stop fuel flow when servicing accessories. Fuel shutoffs in engines room, 03, has to operate as designed. 02 fuel shutoffs were leaking and 01 was free-wheeling and not properly closing as intended.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2023
Resolved 16 October 2023
Resolution: Fuel shutoff adjusted and repaired to satisfaction of marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 October 2023 Resolved
A hatch exposed to the weather must be watertight. Hatch on main deck, starboard side, connecting to the engine room has water leaking into the engine through a loose/rusty bolt.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 16 October 2023
Resolution: Repaired to satisfaction of marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 13 October 2023 Resolved
All accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks are ready for inspection. Engine room contains 02 cracked skips welds in the aft, overhead section.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 16 October 2023
Resolution: Rewelded to satisfaction of marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 January 2022 Resolved
Vessel has not been maintaining monthly test/inspection log for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 January 2022
Resolved 26 January 2022
Resolution: Conducted training with master on how to conduct proper EPIRB testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 January 2022 Resolved
Name was not stenciled on starboard life buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 January 2022
Resolved 26 January 2022
Resolution: Replaced with new life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 January 2022 Resolved
Batteries were expired in multiple floating water lights.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 January 2022
Resolved 26 January 2022
Resolution: Replaced with new batteries.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 January 2022 Resolved
Gage on fire monitor pump did not operate.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 February 2022
Resolved 3 February 2022
Resolution: Witnessed functional gage.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 November 2019 Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable; Vessel was not logging monthly EPIRB inspections; Ensure that monthly EPIRB inspections are logged as per 46 CFR 185.728(a)(c); To the satisfaction of the Coast Guard by 02DEC19.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 19 November 2019
Resolution: Received conformation from the Vessel Rep that he held a meeting with all crewmembers about conducting monthly EPIRB checks, and logging them.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2019 Resolved
Vessel General Permit (VGP) applies to discharges incidental to the normal operation of all non-recreational vessels of 79 feet or greater in length; Vessel did not have a Permit Authorization and Record of Inspection (PARI) form onboard and did not submit annual report to EPA; Obtain PARI form and submit annual report to the EPA as per 40 CFR 122.2; To the satisfaction of the Coast Guard by 02DEC19.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 19 November 2019
Resolution: Received verbal confirmation from Vessel Rep about receipt of the provided forms and guidance.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 November 2019 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve; Lifefloat onboard vessel had extensive cracking around the exterior; Replace lifefloat as per 46 CFR 180.175(a); To the satisfaction of the Coast Guard by 02DEC19.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 19 November 2019
Resolution: Received photographs of the replacement life float from vessel rep.
Communications › Radio Communications › EPIRB
Issued 9 January 2017 Resolved
Vessel's hydrostatic release on the EPIRB was expired
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2017
Resolved 8 February 2017
Resolution: Vessel installed new hydro release
Lifesaving › Rigid Liferafts › Weak Link
Issued 9 January 2017 Resolved
The weak link painter line for both life floats was designed for 11-20 persons. Vessel's had 3 - 12 person liferaft in tandom.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2017
Resolved 8 February 2017
Resolution: Crew installed weak line that was for greater than 21 persons on both sets of life floats
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 January 2017 Resolved
Salt water cooling piping for the #4 main engine was leaking due to a cracked weld. Make repairs prior to operating #4 main.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 8 February 2017
Resolution: Piping was rewelded. Ran main engine for 5 minutes with no leaking under static test
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 January 2017 Resolved
Vessel hasn't worked in 4 months and only a captain was onboard for annual inspection. Conduct all drills prior to getting underway.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 8 February 2017
Resolution: Drills be conducted by the crew prior to sail and follow-up at earliest time with Marine Inspector
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 January 2017 Resolved
Vessel is not logging maintenance, servicing and EPIRB testing in log book while warm stacked.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 8 February 2017
Resolution: logs had been filled for the previous month and will maintain logging with in warm statck status
Operations/Management › Drills/Instruction › Fire
Issued 11 February 2011 Resolved
Perform proper fire drill to the attending marine inspector.
Due 18 February 2011
Resolved 14 February 2011
Resolution: Vessel crew performed fire drill to the satisfaction of attending marine inspector.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 February 2011 Resolved
Lifefloat was missing floating waterlight.
Due 18 February 2011
Resolved 14 February 2011
Resolution: Vessel provided floating waterlight for lifefloat.
Lifesaving › Lifefloat › Markings
Issued 11 February 2011 Resolved
Provide proper markings on lifefloat paddles.
Due 18 February 2011
Resolved 14 February 2011
Resolution: Paddles properly marked.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 December 2009 Resolved
Provide alcohol test strips.
Action required: 705 - Other - as specified
Due 8 January 2010
Resolved 20 December 2009
Resolution: Provided alcohol test strips.
Documentation › Logs/Records › Logbook (official)
Issued 9 December 2009 Resolved
Maintain lifesaving equipment inspection log.
Action required: 705 - Other - as specified
Due 8 January 2010
Resolved 21 November 2011
Resolution: Proper records keeping were in place
Documentation › Logs/Records › Logbook (official)
Issued 9 December 2009 Resolved
Maintain record of completed safety drills
Action required: 705 - Other - as specified
Due 8 January 2010
Resolved 21 November 2011
Resolution: Safety drills conducted and proper records keeping in place
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 9 December 2009 Resolved
Provide un-restricted radio license for radio operator.
Action required: 705 - Other - as specified
Resolved 21 November 2011
Resolution: Capt provided radio telephone operator
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 December 2009 Resolved
Provide latch for oven door
Due 8 January 2010
Resolved 20 December 2009
Resolution: Installed latch on oven door
Documentation › Markings/Placards › Oil Discharge Placard
Issued 9 December 2009 Resolved
Provide oil discharge placard
Due 8 January 2010
Resolved 20 December 2009
Resolution: Provided oil discharge placard
Documentation › Markings/Placards › Garbage Placard
Issued 9 December 2009 Resolved
Provide MARPOL placard for galley and passenger area.
Due 8 January 2010
Resolved 20 December 2009
Resolution: Provided MARPOL placard in areas needed.
Operations/Management › Passenger Operations › Safety Orientation
Issued 9 December 2009 Resolved
Provide copy of emergency instructions in passenger area.
Due 8 January 2010
Resolved 20 December 2009
Resolution: Provided copy of emergency instructions in passenger area.
Lifesaving › Lifefloat › Float-free Link
Issued 1 December 2008 Resolved
Weak links on lifefloats were not attached to vessel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2008
Resolution: Weak links were attached to vessel as required
Electrical › Lighting (service) › Lighting Fixture
Issued 1 December 2008 Resolved
Temporary light fixture was wired into light fixture in crew berthing. Light fixture broken and hanging in second crew berthing. Both presented fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2008
Resolution: Received fax from vessel representative verifying lighting fixtures had been repaired
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 December 2008 Resolved
Davit battery in box aft of bridge missing two battery caps
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2008
Resolution: Received fax from vessel rep verifying battery caps had been replaced.
Construction/Loadline › Penetrations › Gasket
Issued 1 December 2008 Resolved
Emergency escape hatch did not seal properly due to bad gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2008
Resolution: Received fax from vessel rep verifying hatch was repaired.
Communications › Radio Communications › Emergency Source of Power
Issued 1 December 2008 Resolved
SSB not connected to emergency power source.
Due 1 January 2009
Resolved 22 January 2009
Resolution: Received fax from vessel rep verifying SSB had been connected to an emergency power source.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 1 December 2008 Resolved
Installed fixed fire detection system not operational. Vessel also equipped with smoked detectors. Installed system to be repaired or removed.
Due 31 December 2008
Resolved 22 January 2009
Resolution: Received fax from vessel rep verifying fixed system had been corrected.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 December 2008 Resolved
Smoke detector missing from bracket in passageway between berthing areas.
Due 31 December 2008
Resolved 22 December 2008
Resolution: Received fax from vessel rep verifying smoke detector had been replaced.
Construction/Loadline › Structures › Door
Issued 1 December 2008 Resolved
Dogs on watertight door between galley and machinery space need to be tightened.
Due 31 December 2008
Resolved 22 December 2008
Resolution: Received fax from vessel rep verifying watertight door dogs had been adjusted.
Engineering › Compressed Air System (control) › Valve
Issued 1 December 2008 Resolved
Pressure relief valves not tested since 2005. Valves need to be replaced.
Due 31 December 2008
Resolved 22 December 2008
Resolution: Received fax from vessel rep verifying valves had been replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 1 December 2008 Resolved
Dryer vent leaking causing lint buildup behind dryer causing possible fire hazard.
Due 31 December 2008
Resolved 22 December 2008
Resolution: Received fax from vessel rep verifying dryer vent had been corrected.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 7 December 2007 Resolved
A current deviation table was not onboard (2003).
Action required: 705 - Other - as specified
Resolved 7 December 2007
Resolution: Service tech was enroute
Engineering › Compressed Air System (control) › Valve
Issued 7 December 2007 Resolved
The remote shut down for two engines did not function properly.
Action required: 705 - Other - as specified
Resolved 7 December 2007
Lifesaving › Lifefloat › Markings
Issued 7 December 2007 Resolved
The lifefloats were not stenciled on both sides.
Action required: 705 - Other - as specified
Resolved 7 December 2007
Lifesaving › Lifebuoys › Serviceable
Issued 3 December 2007 Resolved
One ring buoy needed new retro reflective tape.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 31 March 2007 Resolved
The bilge alarm wiring in the lazarette was not properly spliced.
Due 31 March 2007
Resolved 12 April 2007
Communications › Visual Communication › Warning Sign (radio room)
Issued 5 March 2007 Resolved
The emergency broadcast placard was not mounted.
Due 31 March 2007
Resolved 12 April 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 5 March 2007 Resolved
The master bilge alarm panel was not functioning properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2007
Resolution: Updated Date in 2015...
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 March 2007 Resolved
The starboard shaft packing gland was not "double nutted".
Due 31 March 2007
Resolved 12 April 2007
Engineering › Electric Propulsion System › Battery Charging Circuitry
Issued 5 March 2007 Resolved
A proper marine grade battery charging unit was not installed.
Due 31 March 2007
Resolved 12 April 2007
Construction/Loadline › Structures › Manhole
Issued 28 February 2007 Resolved
Manhole covers on the aft deck did not have safety chains attached.
Due 31 March 2007
Resolved 12 April 2007
Lifesaving › Lifefloat › Lifeline
Issued 28 February 2007 Resolved
The sea painter and water light lines were not attached around the body of the life float.
Due 31 March 2007
Resolved 12 April 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 28 February 2007 Resolved
Wiring for the sewage pump was not enclosed within a junction box.
Due 31 March 2007
Resolved 12 April 2007
Stability › Unintentional Flooding › General
Issued 28 February 2007 Resolved
Raw water piping for all main engines were not adequately supported.
Due 31 March 2007
Resolved 12 April 2007
Electrical › Electric Generation Source (service) › Generator
Issued 28 February 2007 Resolved
Port and Starboard generator armatures were due for cleaning.
Due 31 March 2007
Resolved 12 April 2007
Fire Fighting › Nozzles › Location
Issued 28 February 2007 Resolved
The nozzle was not attached to the fire station in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2007
Construction/Loadline › Structures › End Bulkhead
Issued 5 December 2003 Resolved
Weld-fill hole in aft watertight bulkhead for potable room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2003
Electrical › Electrical Distribution System (emergency)
Issued 5 December 2003 Resolved
Renew 12v back-up battery for radios. LEGACY COMPONENT DESC: Battery
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2003
Construction/Loadline › Hull › Weld
Issued 5 December 2003 Resolved
Make repairs to all marked cracked frames and welds in engine room.
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 5 December 2003
Navigation
Issued 14 June 1999 Resolved
MAKE NECESSARY REPAIRS TO STEERING SYSTEM TO ENSURE SYSTEM ENGAGES FULLY TOFWD STEERING STATION WHEN GOING FROM AFT STATION TO FWD STATION.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 27 September 1994 Resolved
REPAIR AS ORIGINAL, FRACTURED WELDS IN TRANSOM PORTSIDE BELOW WATERLINE.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994

Casualty record · 2

6 August 2019Routine · role: Acknowledged Pollution Source · activity 7057648
16 January 2022Routine · role: Involved in a Marine Casualty · activity 7426011
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.