PETITE

Built
1983
Last inspected
5 June 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8769810
WDB2268
220697
Flag
UNITED STATES
Maury page id
psix-220697

Documentation record

Registered dimensions (L × B × D)73.1 ft × 56.1 ft × 7.7 ft
Registered tonnagegross 192 / net 150
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN J MELANCON · LAROSE LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 7 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it150 - Regulatory (Subpart C or D), Net Ton
192 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISIONERO Passenger (Inspected) · MISLE 46571 · 1 August 2018 · activity 6498322MISS VIVIAN Passenger (Inspected) · MISLE 50143 · 1 August 2018 · activity 6498322

Inspection history · 19

5 June 2025 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8153097
17 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8113943
24 March 2025 Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8099100
9 December 2024 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8046938
8 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7908901
4 January 2024 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7845989
15 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7825506
6 June 2023 Deficiency Check · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7704700
31 October 2022 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7587181
12 July 2022 Deficiency Check · Annual Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7504755
18 May 2021 Internal Structural Exam · Annual Inspection · MTSA Verification · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7194250
29 July 2020 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7019276
16 September 2019 MTSA Verification · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6810471
4 May 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6682886
1 August 2018 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6498322
18 June 2018 COI Inspection · Deficiency Check · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6450416
31 May 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6430328
27 April 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6400737
21 March 2018 Internal Structural Exam · Drydock Exam · Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6376222

Deficiency record · 28

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2023 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deems necessary to be assured of the safety and seaworthiness of the vessel. The liftboat's forward port leg and starboard aft leg are due for 10-year leg inspections as per Enclosure 2 of CG-543 Policy Letter 07-02 on December 12, 2023. Vessel shall commence leg inspections by January 12, 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2024
Resolved 8 May 2024
Resolution: 10-Year leg inspection completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2022 Resolved
As a result of hitting the Cameron jetty rocks, vessel sustained damage in way of insets in the #2 and #3 starboard ballast tanks as well as possible holes in the starboard #2 void that is currently temp repaired with an epoxy patch. No other breaches of the side or bottom plating has been observed. Damage to leg pads is suspected but unknown at this time. Vessel may proceed to yard in Galveston, Tx to make permanent repairs to hull and to further inspect leg pads. All repairs and inspections shall be made to the satisfaction of the cognizant OCMI / attending Marine Inspector.(705: prior to commercial operations)
Action required: 705 - Other - as specified
Resolved 20 June 2023
Resolution: Damage oversight and repairs conducted at DD. All corrections are under documents tab.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2022 Resolved
All lift boats should be fitted with a level indicator to indicate level height and distinct alarm to warn of uneven leg sinkage when elevated. Marine Inspector observed that the level alarm was inoperable due to excessive corrosion between the metallic components required to make contact and cause the alarm to activate. Per NVIC 8-91 Enclosure (3).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Third party electrician onboard fixed the alarm issue.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022 Resolved
The minimum number of approved 30-inch ring life buoys and the minimum number of which shall have water lights attached, shall be in accordance with Table 94.43-10(a). A minimum of two out of the three required ring life buoys on board shall have water lights attached. Marine Inspector observed only one ring life buoy with a water light attached. (OLD-I) 46CFR94.43-10(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Approved water light was provided and attached to a second life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 July 2022 Resolved
Inflatable liferafts shall be stowed in such a manner that they will float free in the event of the vessel sinking. Marine Inspector observed the liferaft painter lines improperly secured to the tie-down strap connected to the pelican hook instead of being properly secured to the weak link which would prevent the liferafts from floating free if the vessel was to sink. (OLD I) 46CFR94.15-10(c)(4)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Painter line was properly secured to the weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 July 2022 Resolved
It shall be the duty of the master or person in charge to see that the lifeboats, rescue boats, liferafts, lifefloats, and buoyant apparatus are properly maintained at all times, and that all equipment for his vessel required by the regulations in this subchapter is provided, maintained and replaced as indicated. Marine Inspector observed retro-reflective tape strips on the rescue boat were damaged and/or worn and need to be replaced. (OLD I) 46 CFR 97.15-45
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 July 2022
Resolved 13 July 2022
Resolution: Owner provided photo evidence via email of all retroreflective material replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 May 2021 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Marine Inspectors found the vessel rescue boat inoperable, crew was unable to start the rescue boat due to a failure with the internal computer chip. Effect permanent repairs to the affected equipment to the satisfaction of the attending US Coast Guard Inspector. 46 CFR 199.190
Action required: 30 - Ship detained
Resolved 27 May 2021
Resolution: Witnessed a sat. test of the vessel's rescue boat engine. Operator stated it was a bad fuel pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021 Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. Marine Inspectors found the starboard lifebuoy with an inoperable light. Vessel is to repair or replace the light to the satisfaction of the attending US Coast Guard Inspector. 46 CFR 199.70(a)(3)(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Wiring was corrected and the light now works as intended.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2021 Resolved
Containers shall be embossed or bear a brass or equivalent corrosion-resistant name-plate, or otherwise be suitably and permanently marked, to plainly show in letters not less than ½ inch high the following wording: “HAND RED FLARE DISTRESS SIGNALS”. Marine Inspectors found the distress signals stowed in an unmarked watertight container. Vessel is to properly mark the stowage container to the satisfaction of US Coast Guard Marine Inspector. 46 CFR 160.021-6(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
Resolution: Container is labled.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 May 2021 Resolved
Electric installations on vessels must ensure: (2) protection of passengers, crew, other persons, and the vessel from electrical hazards. Marine Inspectors found lighting fixture within the galley hood to be missing its protective cover. Vessels to replace or repair fixture to the satisfaction of the attending US Coast Guard Marine Inspector. 46 CFR 111.01-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
Resolution: Light cover is installed over light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 May 2021 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or designated member of the crew. Marine Inspectors determined that the vessel was not conducting monthly fire extinguishing equipment checks. Vessel is to begin conducting and logging monthly inspections to the satisfaction of the attending US Coast Guard Marine Inspector at the next COI inspection. 46 CFR 91.25-20(a)(1)(ii)
Action required: 705 - Other - as specified
Resolved 15 July 2022
Resolution: Defs cleared due 2022 Annual Inspection, MIs ensure records kept.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021 Resolved
Each pump must be capable of delivering water simultaneously from the highest outlets at a Pitot tube pressure of approximately 50 PSI. The vessel was lowered into the water to run the installed pump (IAW 46 CFR 95.10-5(a)). The pump was air bound and the crew had to get a gallon of water to prime the pump, but were not able to open the plug with the pipe wrench. Furthermore, once the system was running, a crew member stated that the circuit breaker protecting the installed fire pump system would trip and secure power to the installed fire pump system. Finally, the fire hose attached to the starboard side fire hydrant on the main deck had two metal bands and a cam-lock connection to the fire hydrant. Water was observed spraying out of the connection during the operation of the two educator style fire pumps. Effect permanent repairs to the impacted systems to demonstrate an operable installed fire pump and a suitable fire hose to the satisfaction of the attending Marine Inspectors. 46 CFR 95.10-5(c)
Action required: 30 - Ship detained
Resolved 27 May 2021
Resolution: Installed fire pump produced 50 PSIG and new gauges are installed and operational.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 18 May 2021 Resolved
Fire drills must, as far as practicable, be planned with due consideration given to the various emergencies that may occur for that type of vessel its cargo. Marine Inspectors requested that a fire drill be conducted in the laundry room. Marine Inspectors observed that the natural ventilation hatch was not secured on the bulkhead, the mariner with the portable fire extinguisher was inside the space impacted by fire during the entire drill, and the Marine Inspectors did not observe effective communications between the wheel house and the crew on deck. Conduct satisfactory fire drill in the presence of the Marine Inspectors. 46 CFR 97.15-35 46 CFR 199.180(f)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Witnessed a sat. fire drill in laundry.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 18 May 2021 Resolved
The position of the rudder, if power-operated, must be shown at the principal steering station. During a test of the vessel’s rudder system at the operating station, Marine Inspectors observed that the rudder angle indicator depicted a rudder swing from 50 degrees starboard to only 20 degrees port. [name withheld] stated that there were rudder stops in place to prevent the rudder to swing beyond 20 degrees port. Demonstrate that the rudder system and its associated equipment are operational to the satisfaction of the attending Marine Inspectors. 46 CFR 96.05-1(a) 46 113.40-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Wintessed sat test of 45-45 at opeating station.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2021 Resolved
Each EPIRB and each SART, other than an EPIRB or SART in an inflatable life raft, must be tested monthly. The EPIRB must be tested using the integrated test circuit and output indicator to determine that it is operative. Marine Inspectors did not observe a record of the monthly check of the EPIRB, and the Master stated that a record was not kept to verify that a monthly check of the EPIRB was completed. Complete a test of the EPIRB per the monthly test requirements and log that test and future tests to the satisfaction of the attending Marine Inspectors. 46 CFR 96.06-1 46 CFR 199.190(e)(2)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Witnessed sat function test and monthly test record on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021 Resolved
Fire pumps must be fitted with a pressure gage on the discharge side of the pumps. Marine Inspectors observed that the fire hydrant located on the main deck at the base of the forward bulkhead of the super structure (starboard side) had a pressure gauge that was inoperative. The gauge indicated 00 PSIG even though water was being supplied to that hydrant and through its associated hose by the vessel’s two educator style fire pumps. Effect permanent repairs to the impacted equipment to the satisfaction of the attending Marine Inspectors. 46 CFR 95.10-5(e)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Opeational gauge installed and sat. during installed fire pump test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2021 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections, as he deems necessary to be assured of the seaworthiness of the vessel. Marine Inspectors observed that galley refrigerators were not secured to the bulkhead or deck, thereby causing an unsafe condition to the vessel crew. Effect modifications to ensure the refrigerators are secured to prevent shifting to the satisfaction of the attending Marine Inspectors. 46 CFR 91.27-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Refrigerators secured to bulkhead/deck.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 26 September 2019 Resolved
Alcohol test strips (Drug and Alcohol program required) have expired. Replace prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2019
Resolved 27 September 2019
Resolution: New test strips provided onboard.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 26 September 2019 Resolved
Public Announcement system need in conjunction with general alarm is inoperable. General alarm is functioning. Repair PA system within 30 days from this exam.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 29 July 2020
Resolution: PA system repaired and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2019 Resolved
Main fire pump motor not working. (Submersible fire pump is operational, but not suitable when vessel is underway). Repair fire pump motor and prove proper operation of the main fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2019
Resolved 30 July 2020
Resolution: Witnessed satisfactory test of both main and submersible fire pumps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019 Resolved
Main switchboard does not have a functioning ground detection system or a "power available" indicator lamp. Repair both within 30 days from this exam and prove proper operation to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2019
Resolved 29 July 2020
Resolution: Ground detection system and power available lamps repaired and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 September 2019 Resolved
Multiple portable fire extinguishers found on board did not have attached test/inspection data, bringing into question the validity of the third party's(Island Fire & Safety Co.,Inc) inspection report. Provide proof that the required annual inspection of the portable fire extinguisher have been completed to all installed extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2019
Resolved 27 September 2019
Resolution: Third parity returned and inspected all extinguisher missing inspection data and properly labeled all. New report provided.
Construction/Loadline › Hull › Weld
Issued 22 June 2018 Resolved
Starboard leg tower forward brace uppoer weld was not complete and contained a 1/2" gap. Shipyard to repair and 3rd party to complete NTD.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 26 June 2018
Resolution: zNDT report provided and found satisfactory.
Construction/Loadline › Markings › Load Line Mark
Issued 21 June 2018 Resolved
Load Line marks were missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Resolution: Load line markings placed on hull.
Stability › Watertight Integrity › General
Issued 21 June 2018 Resolved
Engine room WTD gasket was installed improperly. Crew to replace
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 June 2018 Resolved
Vessel name and hailing port on stern needs renewed.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Resolution: Stern name and hailing port stenciled.
Lifesaving › Lifebuoys › Quantity
Issued 21 June 2018 Resolved
Quantity of life buoys was 3 IAW old subchapter I. Vessel requires 8 IAW chapter L all OSV site.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Resolution: New lifebouys installed.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 18 April 2018 Resolved
Portside strut propeller shaft water lubricated bearing was damaged by line. Replace shaft bearing prior to departing Amelia, LA to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 19 April 2018
Resolved 27 April 2018
Resolution: Rudder shaft bearing replaced

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.