MAURY USCG vessel records Sign in
← All vessels

PETITE

PETITE is a 1983 offshore supply vessel. The Coast Guard has recorded 74 inspections since 1989, most recently in June 2025, along with 97 deficiencies, 1 operational control and 6 casualty investigations between 1992 and 2022.

Records from 1989 to 2025. Most recent: inspection, 5 June 2025.

Built
1983
Last inspected
5 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8769810 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB2268
220697
Flag
UNITED STATES
366874110
Maury page id
psix-220697

Inspections, by type

…with no type recorded13
Years with a record 32 calendar years (1989–2025)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)73.1 ft × 56.1 ft × 7.7 ft
Registered tonnagegross 192 / net 150
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN J MELANCON · LAROSE LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it150 - Regulatory (Subpart C or D), Net Ton
192 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB2268MMSI 366874110 · active · compulsorily equipped · granted 9 December 2022, expires 13 November 2032
WCO5247MMSI not assigned · expired · compulsorily equipped · granted 1 November 1994, cancelled 1 January 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISIONERO Passenger (Inspected) · MISLE 46571 · 1 August 2018 · activity 6498322MISS VIVIAN Passenger (Inspected) · MISLE 50143 · 1 August 2018 · activity 6498322CAVALCADE Offshore Supply Vessel · MISLE 53308 · 21 June 2006 · activity 2695097LANDON JAMES Passenger (Inspected) · MISLE 321436 · 16 August 2000 · activity 130548

Inspection history · 74

5 June 2025 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8153097
17 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8113943
24 March 2025 Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8099100
9 December 2024 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8046938
8 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7908901
4 January 2024 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7845989
15 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7825506
6 June 2023 Deficiency Check · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7704700
31 October 2022 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7587181
12 July 2022 Deficiency Check · Annual Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7504755
18 May 2021 Internal Structural Exam · Annual Inspection · MTSA Verification · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7194250
29 July 2020 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7019276
16 September 2019 MTSA Verification · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6810471
4 May 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6682886
1 August 2018 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6498322
18 June 2018 COI Inspection · Deficiency Check · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6450416
31 May 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6430328
27 April 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6400737
21 March 2018 Internal Structural Exam · Drydock Exam · Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6376222
13 November 2015 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5764567
6 October 2014 Internal Structural Exam · Examination of Repairs · Hull Examination · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4999674
9 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4884225
16 May 2014 Examination of Repairs · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4858773
13 September 2011 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4144602
21 September 2010 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3854774
27 April 2009 Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3461980
23 April 2009 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3459014
4 September 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3311033
26 September 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3066462
5 October 2006 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2794230
7 July 2006 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2733736
21 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2695097
4 November 2005 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2527190
2 November 2004 Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2232908
21 September 2004 Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2200862
17 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2168993
17 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2169018
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998585
20 November 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1950917
29 January 2003 Damage Survey · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1737113
18 November 2002 Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1707219
8 November 2002 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1701803
14 September 2001 COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448303
16 February 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 715773
25 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1055316
16 August 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 22295
16 August 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 130548
3 September 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411966
17 September 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 225354
17 September 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451334
14 August 1998 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802124
2 September 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390594
30 September 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1145684
27 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141394
29 August 1996 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371521
14 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084008
11 January 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1193346
8 December 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 876874
20 October 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355579
13 September 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866389
30 August 1994 Inclining Experiment · Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412691
25 February 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947173
21 February 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 69513
23 July 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 674180
24 June 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228878
11 April 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 996916
4 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905703
1 August 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927092
23 February 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242346
16 December 1989 Deficiency Check · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218655
17 November 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217151
23 October 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888639
31 August 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197025
29 June 1989 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348504

Deficiency record · 97

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2023 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deems necessary to be assured of the safety and seaworthiness of the vessel. The liftboat's forward port leg and starboard aft leg are due for 10-year leg inspections as per Enclosure 2 of CG-543 Policy Letter 07-02 on December 12, 2023. Vessel shall commence leg inspections by January 12, 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2024
Resolved 8 May 2024
Resolution: 10-Year leg inspection completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2022 Resolved
As a result of hitting the Cameron jetty rocks, vessel sustained damage in way of insets in the #2 and #3 starboard ballast tanks as well as possible holes in the starboard #2 void that is currently temp repaired with an epoxy patch. No other breaches of the side or bottom plating has been observed. Damage to leg pads is suspected but unknown at this time. Vessel may proceed to yard in Galveston, Tx to make permanent repairs to hull and to further inspect leg pads. All repairs and inspections shall be made to the satisfaction of the cognizant OCMI / attending Marine Inspector.(705: prior to commercial operations)
Action required: 705 - Other - as specified
Resolved 20 June 2023
Resolution: Damage oversight and repairs conducted at DD. All corrections are under documents tab.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2022 Resolved
All lift boats should be fitted with a level indicator to indicate level height and distinct alarm to warn of uneven leg sinkage when elevated. Marine Inspector observed that the level alarm was inoperable due to excessive corrosion between the metallic components required to make contact and cause the alarm to activate. Per NVIC 8-91 Enclosure (3).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Third party electrician onboard fixed the alarm issue.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022 Resolved
The minimum number of approved 30-inch ring life buoys and the minimum number of which shall have water lights attached, shall be in accordance with Table 94.43-10(a). A minimum of two out of the three required ring life buoys on board shall have water lights attached. Marine Inspector observed only one ring life buoy with a water light attached. (OLD-I) 46CFR94.43-10(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Approved water light was provided and attached to a second life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 July 2022 Resolved
Inflatable liferafts shall be stowed in such a manner that they will float free in the event of the vessel sinking. Marine Inspector observed the liferaft painter lines improperly secured to the tie-down strap connected to the pelican hook instead of being properly secured to the weak link which would prevent the liferafts from floating free if the vessel was to sink. (OLD I) 46CFR94.15-10(c)(4)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 July 2022
Resolved 12 July 2022
Resolution: Painter line was properly secured to the weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 July 2022 Resolved
It shall be the duty of the master or person in charge to see that the lifeboats, rescue boats, liferafts, lifefloats, and buoyant apparatus are properly maintained at all times, and that all equipment for his vessel required by the regulations in this subchapter is provided, maintained and replaced as indicated. Marine Inspector observed retro-reflective tape strips on the rescue boat were damaged and/or worn and need to be replaced. (OLD I) 46 CFR 97.15-45
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 July 2022
Resolved 13 July 2022
Resolution: Owner provided photo evidence via email of all retroreflective material replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 May 2021 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Marine Inspectors found the vessel rescue boat inoperable, crew was unable to start the rescue boat due to a failure with the internal computer chip. Effect permanent repairs to the affected equipment to the satisfaction of the attending US Coast Guard Inspector. 46 CFR 199.190
Action required: 30 - Ship detained
Resolved 27 May 2021
Resolution: Witnessed a sat. test of the vessel's rescue boat engine. Operator stated it was a bad fuel pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021 Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. Marine Inspectors found the starboard lifebuoy with an inoperable light. Vessel is to repair or replace the light to the satisfaction of the attending US Coast Guard Inspector. 46 CFR 199.70(a)(3)(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Wiring was corrected and the light now works as intended.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2021 Resolved
Containers shall be embossed or bear a brass or equivalent corrosion-resistant name-plate, or otherwise be suitably and permanently marked, to plainly show in letters not less than ½ inch high the following wording: “HAND RED FLARE DISTRESS SIGNALS”. Marine Inspectors found the distress signals stowed in an unmarked watertight container. Vessel is to properly mark the stowage container to the satisfaction of US Coast Guard Marine Inspector. 46 CFR 160.021-6(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
Resolution: Container is labled.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 May 2021 Resolved
Electric installations on vessels must ensure: (2) protection of passengers, crew, other persons, and the vessel from electrical hazards. Marine Inspectors found lighting fixture within the galley hood to be missing its protective cover. Vessels to replace or repair fixture to the satisfaction of the attending US Coast Guard Marine Inspector. 46 CFR 111.01-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
Resolution: Light cover is installed over light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 May 2021 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or designated member of the crew. Marine Inspectors determined that the vessel was not conducting monthly fire extinguishing equipment checks. Vessel is to begin conducting and logging monthly inspections to the satisfaction of the attending US Coast Guard Marine Inspector at the next COI inspection. 46 CFR 91.25-20(a)(1)(ii)
Action required: 705 - Other - as specified
Resolved 15 July 2022
Resolution: Defs cleared due 2022 Annual Inspection, MIs ensure records kept.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021 Resolved
Each pump must be capable of delivering water simultaneously from the highest outlets at a Pitot tube pressure of approximately 50 PSI. The vessel was lowered into the water to run the installed pump (IAW 46 CFR 95.10-5(a)). The pump was air bound and the crew had to get a gallon of water to prime the pump, but were not able to open the plug with the pipe wrench. Furthermore, once the system was running, a crew member stated that the circuit breaker protecting the installed fire pump system would trip and secure power to the installed fire pump system. Finally, the fire hose attached to the starboard side fire hydrant on the main deck had two metal bands and a cam-lock connection to the fire hydrant. Water was observed spraying out of the connection during the operation of the two educator style fire pumps. Effect permanent repairs to the impacted systems to demonstrate an operable installed fire pump and a suitable fire hose to the satisfaction of the attending Marine Inspectors. 46 CFR 95.10-5(c)
Action required: 30 - Ship detained
Resolved 27 May 2021
Resolution: Installed fire pump produced 50 PSIG and new gauges are installed and operational.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 18 May 2021 Resolved
Fire drills must, as far as practicable, be planned with due consideration given to the various emergencies that may occur for that type of vessel its cargo. Marine Inspectors requested that a fire drill be conducted in the laundry room. Marine Inspectors observed that the natural ventilation hatch was not secured on the bulkhead, the mariner with the portable fire extinguisher was inside the space impacted by fire during the entire drill, and the Marine Inspectors did not observe effective communications between the wheel house and the crew on deck. Conduct satisfactory fire drill in the presence of the Marine Inspectors. 46 CFR 97.15-35 46 CFR 199.180(f)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Witnessed a sat. fire drill in laundry.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 18 May 2021 Resolved
The position of the rudder, if power-operated, must be shown at the principal steering station. During a test of the vessel’s rudder system at the operating station, Marine Inspectors observed that the rudder angle indicator depicted a rudder swing from 50 degrees starboard to only 20 degrees port. [name withheld] stated that there were rudder stops in place to prevent the rudder to swing beyond 20 degrees port. Demonstrate that the rudder system and its associated equipment are operational to the satisfaction of the attending Marine Inspectors. 46 CFR 96.05-1(a) 46 113.40-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Wintessed sat test of 45-45 at opeating station.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2021 Resolved
Each EPIRB and each SART, other than an EPIRB or SART in an inflatable life raft, must be tested monthly. The EPIRB must be tested using the integrated test circuit and output indicator to determine that it is operative. Marine Inspectors did not observe a record of the monthly check of the EPIRB, and the Master stated that a record was not kept to verify that a monthly check of the EPIRB was completed. Complete a test of the EPIRB per the monthly test requirements and log that test and future tests to the satisfaction of the attending Marine Inspectors. 46 CFR 96.06-1 46 CFR 199.190(e)(2)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Witnessed sat function test and monthly test record on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021 Resolved
Fire pumps must be fitted with a pressure gage on the discharge side of the pumps. Marine Inspectors observed that the fire hydrant located on the main deck at the base of the forward bulkhead of the super structure (starboard side) had a pressure gauge that was inoperative. The gauge indicated 00 PSIG even though water was being supplied to that hydrant and through its associated hose by the vessel’s two educator style fire pumps. Effect permanent repairs to the impacted equipment to the satisfaction of the attending Marine Inspectors. 46 CFR 95.10-5(e)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2021
Resolution: Opeational gauge installed and sat. during installed fire pump test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2021 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections, as he deems necessary to be assured of the seaworthiness of the vessel. Marine Inspectors observed that galley refrigerators were not secured to the bulkhead or deck, thereby causing an unsafe condition to the vessel crew. Effect modifications to ensure the refrigerators are secured to prevent shifting to the satisfaction of the attending Marine Inspectors. 46 CFR 91.27-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Refrigerators secured to bulkhead/deck.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 26 September 2019 Resolved
Alcohol test strips (Drug and Alcohol program required) have expired. Replace prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2019
Resolved 27 September 2019
Resolution: New test strips provided onboard.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 26 September 2019 Resolved
Public Announcement system need in conjunction with general alarm is inoperable. General alarm is functioning. Repair PA system within 30 days from this exam.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 29 July 2020
Resolution: PA system repaired and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2019 Resolved
Main fire pump motor not working. (Submersible fire pump is operational, but not suitable when vessel is underway). Repair fire pump motor and prove proper operation of the main fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2019
Resolved 30 July 2020
Resolution: Witnessed satisfactory test of both main and submersible fire pumps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019 Resolved
Main switchboard does not have a functioning ground detection system or a "power available" indicator lamp. Repair both within 30 days from this exam and prove proper operation to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2019
Resolved 29 July 2020
Resolution: Ground detection system and power available lamps repaired and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 September 2019 Resolved
Multiple portable fire extinguishers found on board did not have attached test/inspection data, bringing into question the validity of the third party's(Island Fire & Safety Co.,Inc) inspection report. Provide proof that the required annual inspection of the portable fire extinguisher have been completed to all installed extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2019
Resolved 27 September 2019
Resolution: Third parity returned and inspected all extinguisher missing inspection data and properly labeled all. New report provided.
Construction/Loadline › Hull › Weld
Issued 22 June 2018 Resolved
Starboard leg tower forward brace uppoer weld was not complete and contained a 1/2" gap. Shipyard to repair and 3rd party to complete NTD.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 26 June 2018
Resolution: zNDT report provided and found satisfactory.
Construction/Loadline › Markings › Load Line Mark
Issued 21 June 2018 Resolved
Load Line marks were missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Resolution: Load line markings placed on hull.
Stability › Watertight Integrity › General
Issued 21 June 2018 Resolved
Engine room WTD gasket was installed improperly. Crew to replace
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 June 2018 Resolved
Vessel name and hailing port on stern needs renewed.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Resolution: Stern name and hailing port stenciled.
Lifesaving › Lifebuoys › Quantity
Issued 21 June 2018 Resolved
Quantity of life buoys was 3 IAW old subchapter I. Vessel requires 8 IAW chapter L all OSV site.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2018
Resolved 22 June 2018
Resolution: New lifebouys installed.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 18 April 2018 Resolved
Portside strut propeller shaft water lubricated bearing was damaged by line. Replace shaft bearing prior to departing Amelia, LA to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 19 April 2018
Resolved 27 April 2018
Resolution: Rudder shaft bearing replaced
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 13 November 2015 Resolved
Rudder angle indicator is not functioning or indicating rudder position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2015
Resolved 2 December 2015
Resolution: Tested angle rudder indicator.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 November 2015 Resolved
CO2 bottle found empty. Inspect, recharge and replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2015
Resolved 13 November 2015
Resolution: CO2 bottle replaced. Corrected on the spot.
Construction/Loadline › Structures › Ventilators
Issued 13 November 2015 Resolved
All manual closure doors for engine room vents must be maintained or repaired to allow proper closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2015
Resolved 2 December 2015
Resolution: Verified proper closuer of vents.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 November 2015 Resolved
Update fire fighting plan to show current arrangment of Fire fighting and Lifesaving equipment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 24 November 2015
Resolution: Reviewed updated version of fire and safety plan. All sat.
Engineering › Steering Gear System › Rudder
Issued 27 April 2009 Resolved
Vsl to prove proper operation of all steering and propulsion systems prior to conducting operations.
Action required: 705 - Other - as specified
Resolved 30 November 2009
Engineering › Electric Propulsion System › Battery
Issued 4 September 2008 Resolved
Battery boxes were not secured or properly covered
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 September 2008
Resolution: Battery boxes were secured with an aircraft tie down
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 4 September 2008 Resolved
Laundry dryer ventilation duct was crushed and exhaust was venting into laundry space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 5 September 2008
Resolution: New duct installed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 September 2008 Resolved
Three extinguisher were not serviced
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 5 September 2008
Resolution: All extinguishers were weighted
Fire Fighting › Means of Escape › Doorways
Issued 4 September 2008 Resolved
Self closing fire doors did not fully close on 3 decks in the stairwell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 September 2008
Resolution: Adjustments made to doors
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 September 2008 Resolved
E-lighting fixture in galley was inoperable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 September 2008
Resolution: Installed new fixture
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 September 2008 Resolved
PML's expired or missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 September 2008
Resolution: New PML''s installed on all lifejackets
Engineering › Fuel Oil Service System › Piping
Issued 4 September 2008 Resolved
Fuel line for Gen-set was leaking IWO port side engine room fwd bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 September 2008
Resolution: repaired leak
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 September 2008 Resolved
First aid kit contained expired medicines
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 September 2008
Resolution: New medicines ordered.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 26 September 2007 Resolved
Repair inoperable showers. The vessel is limited to 24 persons on board until repairs are complete.
Condition: Improper/Lack of Maintenance
Due 10 October 2007
Resolved 5 October 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 26 September 2007 Resolved
Remove file cabinet from upper deck passage. Cabinet is not secured to prevent movement and obstructs an egress route.
Condition: Placed in Improper Service
Due 10 October 2007
Resolved 5 October 2007
Electrical › Lighting (service) › Outlet Box
Issued 26 September 2007 Resolved
Renew deteriorated and broken electrical junction box IWO 02deck aft house bulkhead light fixture above external walkway
Condition: Improper/Lack of Maintenance
Due 10 October 2007
Resolved 5 October 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 26 September 2007 Resolved
Renew broken flourescent light fixture in port engine room above access ladder.
Condition: Unknown
Due 5 October 2007
Resolved 5 October 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 2 November 2004 Resolved
Permanently install wiring for the power to the load indicator and radio charger for the forward crane.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 16 November 2004
Resolution: Wiring permanently installed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 November 2004 Resolved
Repair leaking fuel return line in way of piping return to the fuel storage tank.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 16 November 2004
Resolution: Leak repaired.
Navigation › Piloting/Steering › Marine Charts
Issued 2 November 2004 Resolved
Provide corrected charts for vessel operating area.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 16 November 2004
Resolution: Charts provided.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 2 November 2004 Resolved
Provide documentation for minimum and maximum load angle proof tests.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 16 November 2004
Resolution: Documentation and test results provided.
Engineering › Compressed Air System (start air) › Piping
Issued 2 November 2004 Resolved
Replace seal on start air regulator for the starboard main engine.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 16 November 2004
Resolution: Seal replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2004 Resolved
Use proper pressure connectors and properly deadend wiring in the pilot house console.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 16 November 2004
Resolution: Pressure connectors installed, deadend wiring removed.
Construction/Loadline › Hull
Issued 29 January 2003 Resolved
Crop and renew to good metal damage to starboard engineroom aft side shell and starboard aft wing tank. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 13 February 2003
Resolved 4 February 2003
Resolution: Witnessed sat repair.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 November 2002 Resolved
Install insulated cover for welding machine circuit breaker box.
Due 22 November 2002
Resolved 8 November 2002
Electrical › Lighting (emergency)
Issued 8 November 2002 Resolved
Modify electrical supply to emergency embarkation lighting on stern. Current supply is fed off switched circuit for deck lights.
Due 22 November 2002
Resolved 8 November 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 November 2002 Resolved
Identify and repair exhaust leak on starboard main engine exhaust syatem
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting › Structural - A Class Divisions
Issued 8 November 2002 Resolved
Re-install door handles and ajust fire doors throughout vessel.
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting › Remote Fuel Shutoff
Issued 8 November 2002 Resolved
Install stand off and guide for emergency fuel cutout valve reach rods for port and stbd enginerooms.
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting › Combustible Materials
Issued 8 November 2002 Resolved
Provide identification and fire rating of fiberglass grating throughout enginerooms.
Due 22 November 2002
Resolved 20 November 2003
Resolution: Documentation was provided.
Fire Fighting › Means of Escape
Issued 8 November 2002 Resolved
Prior to operating, prove proper operation of port and stbd engineroom emergency escape hatches.
Due 8 November 2002
Resolved 8 November 2002
Pollution Prevention/Response › Prevention Equipment
Issued 8 November 2002 Resolved
Prior to transfer operations, hydrostatically test fuel oil transfer hose.
Due 22 November 2002
Resolved 8 November 2002
Resolution: New hoses tested and placed onboard vessel.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 November 2002 Resolved
Prior to fueling operations, provide proper closing devices for fuel oil containments.
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting › Miscellaneous Items
Issued 8 November 2002 Resolved
Prior to operating, remove oil and residues from port and stbd engine rooms to include exhaust fans, bilges and bulkheads.
Due 8 November 2002
Resolved 8 November 2002
Construction/Loadline
Issued 8 November 2002 Resolved
Free up all dogging devices for closures on main deck
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting › Remote Fuel Shutoff
Issued 8 November 2002 Resolved
Properly stencil fuel oil cutout valves on main deck.
Due 22 November 2002
Resolved 8 November 2002
Engineering
Issued 8 November 2002 Resolved
Mount pilot valve for jacking gear system in stbd engineroom.
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting › Miscellaneous Items
Issued 8 November 2002 Resolved
Install proper flame screens for fuel oil vents.
Due 22 November 2002
Resolved 8 November 2002
Construction/Loadline › Hull
Issued 8 November 2002 Resolved
Repair fracture in bulkhead on front of house, main deck.
Due 22 November 2002
Resolved 8 November 2002
Fire Fighting
Issued 14 September 2001 Resolved
Install closure arms on fire door inside house main deck, house 01-02 levelconnecting stair tower, and adjust closure tension on fire door 02-02 levelconnecting stair tower.
Condition: Unknown
Due 14 October 2001
Resolved 4 December 2001
Documentation
Issued 14 September 2001 Resolved
Provide on board vsl approved new operations manual.
Condition: Unknown
Due 14 January 2002
Resolved 13 March 2003
Lifesaving
Issued 14 September 2001 Resolved
Install general alarm bell on exterior bulkhead forward of the pilot house.
Condition: Unknown
Due 14 October 2001
Resolved 9 October 2001
Fire Fighting
Issued 14 September 2001 Resolved
Submit new fire control safety plan to MSO NOLA for approval.
Condition: Unknown
Due 16 November 2001
Resolved 9 October 2001
Documentation
Issued 14 September 2001 Resolved
Provide on board vsl new approved stability letter based on 06SEP01 inclining experiment.
Condition: Unknown
Due 14 January 2002
Resolved 13 March 2003
Lifesaving
Issued 3 September 1999 Resolved
DEMONSTRATE COMPLIANCE WITH CGD8 POLICY "RESCUE BOAT REQUIREMENTS FOR OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDINGMARINE INSPECTOR.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 29 August 1996 Resolved
PROVIDE PAINT LOCKER WITH FIXED FIRE FIGHTING SYSTEM, ADD TO FIRE PLAN AND RESUBMIT TO OCMI FOR APPROVAL.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Electrical
Issued 29 August 1996 Resolved
REPLACE LAGGING ON GENERATORS AND STBD DIESEL ENGINE AS NEEDED.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Electrical
Issued 29 August 1996 Resolved
REPAIR OR REPLACE EMERGENCY LIGHTS IN PORT ENGINE ROOM.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Electrical
Issued 29 August 1996 Resolved
REWIRE OR REPLACE SPOTLIGHTS ON PORT AND STARBOARD FORWARD LEGS WERE WIRES ARE BROKEN.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Engineering
Issued 20 October 1995 Resolved
PROVIDE EVIDENCE OF HYDRO TEST FOR 2" X 50' FUEL TRANSFER HOSE.
Condition: Unknown
Due 27 October 1995
Resolved 22 November 1995
Navigation
Issued 20 October 1995 Resolved
PROVE OPERATION OF RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 27 October 1995
Resolved 22 November 1995
Lifesaving
Issued 30 August 1994 Resolved
PROVIDE ONBOARD AND POST AN APPROVED SAFETY PLAN TO THE SATISFACTION OF THECOGNIZANT OCMI.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Documentation
Issued 30 August 1994 Resolved
PROVIDE ONBOARD A STAMPED APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
PROVIDE ONBOARD A BOAT HOOK FOR EACH LIFEFLOAT. TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Engineering
Issued 30 August 1994 Resolved
PROVIDE GUARD FOR AIR COMPRESSOR PULLEY. TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Engineering
Issued 30 August 1994 Resolved
PROVIDE USCG APPROVED F.O. HOSE FOR GENERATORS. TO BE TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Documentation
Issued 30 August 1994 Resolved
PROVIDE ONBOARD AND POST AN APPROVED STABILITY LETTER FROM MARINE SAFETY CENTER.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Documentation
Issued 30 August 1994 Resolved
PROVIDE APPROVED ELECTRICAL SYSTEM DRAWINGS, JACKING GEAR INSTALLATION (HYDRAULIC SYSTEM), CRANE INSTALLATION (FOUNDATION STRUCTURE) AND INBOARD/OUTBOARD PROFILE FOR MODS DONE WHILE IN MSO MOBILE ZONE. SEE REF CASE FOR DETAILS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Documentation
Issued 1 August 1990 Resolved
PROVE RECIEPT OF RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Construction/Loadline
Issued 29 June 1989 Resolved
PROVIDE ANCHOR AND 360 FEET OF LINE/CABLE WITH MINIMUM OF 3200 LBS OF HOLDING CAPACITY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
PROVIDE APPROVED RESCUE BOAT AND METHOD TO LAUNCH BOAT.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Unknown
Issued 29 June 1989 Resolved
PROVIDE APPROVED TILT ALARM.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
PROVIDE MEANS OF ESCAPE FROM VESSEL IN JACKED UP MODE.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 29 June 1989 Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY 46 CFR 91.5.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 29 June 1989 Resolved
PROVIDE STABILITY TEST AND LETTER AS REQUIRED BY 46 CFR SUBCHAPTER "S".
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Engineering
Issued 29 June 1989 Resolved
PROVIDE TAILSHAFT EXAM AS REQUIRED BY 46 CFR 61.20-15.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 29 June 1989 Resolved
SUBMIT OPERATING MANUAL FOR APPROVAL.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Deck/Cargo
Issued 29 June 1989 Resolved
PROVIDE TESTS OF STARBOARD INSTALLED CRANE.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
PROVIDE LINE THROWING GUN AND KIT AS REQUIRED BY 46 CFR 94.45.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989

Casualty record · 6

21 February 1992Major Marine Casualty · role: Involved in a Marine Casualty · activity 69513
16 August 2000Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 130548
21 June 2006Routine · role: Involved in a Marine Casualty · activity 2695097
23 April 2009Routine · role: Involved in a Marine Casualty · activity 3459014
1 August 2018Routine · role: Transiting Vicinity of Primary Subject · activity 6498322
28 October 2022Routine · role: Involved in a Marine Casualty · activity 7593826
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.