MISIONERO

MISIONERO is a 1970 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 1982, most recently in October 2020, along with 38 deficiencies, 1 operational control and 1 casualty investigation in 2018.

Records from 1982 to 2020. Most recent: inspection, 1 October 2020.

Built
1970
Last inspected
1 October 2020
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4451
Flag
UNITED STATES
367128780, 368121880
Maury page id
psix-46571

Inspections, by type

…with no type recorded11
Years with a record 18 calendar years (1982–2020)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 16.6 ft × 7.8 ft
Registered tonnagegross 52 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBROWNSVILLE, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL3468MMSI 368121880 · active · compulsorily equipped · granted 27 November 2019, expires 27 November 2029
WDJ4451MMSI 367128780 · active · compulsorily equipped · granted 20 March 2017, expires 20 March 2027
WDD3314MMSI 367128780 · expired · compulsorily equipped · granted 12 July 2006, cancelled 17 September 2016
WCW2734MMSI not assigned · expired · voluntarily equipped · granted 5 March 1996, cancelled 6 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS VIVIAN Passenger (Inspected) · MISLE 50143 · 1 August 2018 · activity 6498322PETITE Offshore Supply Vessel · MISLE 220697 · 1 August 2018 · activity 6498322

Inspection history · 33

1 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7070008
14 January 2019 Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6609996
1 August 2018 Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6498279
1 August 2018 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6498322
13 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6391086
12 April 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6390415
20 February 2018 Hull Examination · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6358096
20 March 2017 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6106829
3 March 2017 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6083297
14 March 2016 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5833957
8 January 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5792145
25 July 2012 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4390494
22 February 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4243697
5 March 2010 Deficiency Check · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3689683
1 February 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3673309
20 January 2009 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3392636
14 January 2008 Internal Structural Exam · Annual Inspection · Simplified Stability Test · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3124651
27 July 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3009061
19 September 2006 Hull Examination · COI Inspection · Simplified Stability Test
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2732439
16 November 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 892952
8 September 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1003341
25 March 1987 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1325908
18 September 1986 Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1310046
20 March 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 995024
18 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1289761
29 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288209
28 February 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977920
23 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280249
19 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972267
7 June 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277319
8 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966999
5 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277541
31 March 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278077

Deficiency record · 38

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel reported a machinery space fire on starboard MDE. Any required repairs shall be approved by the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2018
Resolved 17 August 2018
Resolution: Fixed firefighting system replaced in kind with 1500 cubic foot CO2 system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated. Starboard main diesel engine is missing lagging from turbo to exhaust water-cooling inlet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2018
Resolved 17 August 2018
Resolution: Replaced turbo seal and lagging.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 April 2018 Resolved
A vessel must comply with the applicable requirements for any radio, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels Bridge to Bridge and Radio safety Certificates expired 15APR18. Vessel restricted to operations no more than 1,000ft from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 15 May 2018
Resolution: Vessel provided a newly issued Radio Safety Certificate
Lifesaving › Lifefloat › Float-free Link
Issued 30 April 2018 Resolved
In addition to meeting § 180.130, each life float and buoyant apparatus must be stowed as required under this section, The float-free link required by 180.130(a)(1) must be:(1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant; (2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag; and (3) Secured to the painter at one end and to the vessel on the other end. Vessels Life Floats are not attached to the vessel using an proper and approved weak link. Vessel restricted to no more than 3 miles from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 15 May 2018
Resolution: Vessel properly installed new week links IAW CFR
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 April 2018 Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly. Vessel Does not have any approved means to preform alcohol testing on board the vessel. Vessel is restricted to 2 hours from a testing facility.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 15 May 2018
Resolution: Vessel provided approved Alcohol Test Strips
Lifesaving › Hand Flares › Quantity
Issued 30 April 2018 Resolved
[?4/?30/?2018 3:01 PM] Coleman, Brian C MSSE2: A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, and Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Vessel only had 6 hand red distress signals on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 30 April 2018
Resolution: Vessel Master provided 6 additional flares to meet quantity requirements.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 30 April 2018 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date (1)Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have a U.S. Coast Pilot or Tide Tables on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 15 May 2018
Resolution: Vessel provided current publications of all missing Tables
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 April 2018 Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Each vessel must undergo an Annual inspection 3 months before or after each anniversary date. The vessels Certificate of Inspection anniversary date is 13 January 2018. Vessel may not operate after 13 April until a COI Annual Inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2018
Resolution: Vessel completed Annual Inspection and has a valid endorsed COI onboard.
Fire Fighting › Fire Bucket › Quantity
Issued 3 March 2017 Resolved
Vessel is required to have three 2.5 gallon fire buckets. Vessel only has two buckets. Restricted from operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2017
Resolved 3 March 2017
Resolution: Third 2.5 gallon bucket added on board.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 March 2017 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Lights are not operational. Restricted to within three miles from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 3 March 2017
Resolution: Replaced batteries for lights.
Lifesaving › Hand Flares › Quantity
Issued 3 March 2017 Resolved
Vessel is required to have 6 red hand flares and 6 orange hand smokes. Vessel only has 6 red flares and 5 orange hand smokes. Restricted to lakes, bays, and sounds route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 3 March 2017
Resolution: Vessel rep produced additional hand flare. 12 total.
Fire Fighting › Ventilation Systems › Ducts
Issued 3 March 2017 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Pins are missing and vents are unable to close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 3 March 2017
Resolution: Vessel provided securing pins for engine room vents.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 March 2017 Resolved
Vessel must be equipped with at least two portable battery lights. One of these lights must be at the operating station. Vessel is missing both lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 3 March 2017
Resolution: Vessel rep produced both portable lights.
Documentation › Certificates/Documents › FCC SSL
Issued 3 March 2017 Resolved
Stations in the maritime service must be licensed by the FCC. FCC ship radio station authorization is expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 20 March 2017
Resolution: Vessel representative provided a valid FCC Radio Station Authorization Certificate.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 March 2016 Resolved
Vessel did not complete Annual Inspection due to several hazardous conditions and vessel rep cancelled inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 21 March 2016
Resolution: Attending MI completed Annual Inspection.
Construction/Loadline › Hull › Girder
Issued 5 March 2010 Resolved
Repair fractured welds behind stbd steering gear in lazzarette
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 22 March 2010
Resolution: Repaired fractured welds.
Construction/Loadline › Hull › Girder
Issued 5 March 2010 Resolved
Repair welds underneath bits on both port and stbd side in lazzerette.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 22 March 2010
Resolution: Repaired welds.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 March 2010 Resolved
Seal penetrations forward and aft in engine room, make air tight.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 22 March 2010
Resolution: Sealed penetrations in engine room.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 March 2010 Resolved
Repair fractured hand rail stbd side of pilothouse.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 22 March 2010
Resolution: Repaired fractured hand rail.
Construction/Loadline › Structures › Manhole
Issued 5 March 2010 Resolved
Lubricate emergency hatch in berthing area both hinges and handle packing.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 22 March 2010
Resolution: Emergency hatch is now easily opened.
Construction/Loadline › Hull › Weld
Issued 5 March 2010 Resolved
Repair fractures in forepeak 12 total as marked.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 22 March 2010
Resolution: Repaired fractures in forepeak.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 5 March 2010 Resolved
Replace cutlass bearing on port and stbd shafts.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 8 March 2010
Resolution: Replaced cutlass bearing on port and stbd shafts.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 3 February 2010 Resolved
Remove surge protector used in galley and permanently install approved outlet
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 February 2010
Resolved 4 February 2010
Resolution: Surge protector removed from galley and microwave disconnected until a permanent outlet is installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2010 Resolved
Properly mount electrical wiring in space under galley
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2010
Resolved 4 February 2010
Resolution: Wiring properly mounted with metal clamps in space under galley
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 3 February 2010 Resolved
Install proper barriers/rail on stove to prevent movement while underway.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2010
Resolved 4 February 2010
Resolution: Metal rails installed around stove top.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 February 2010 Resolved
B-1 fire extinguisher service certificate expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2010
Resolved 4 February 2010
Resolution: B-1 extinguisher properly serviced and marked appropriately on certificate to reflect as such
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 January 2009 Resolved
Vessel overdue for 2008 annual exam. Complete satisfactory exam prior to carrying passengers and not later than 20JAN09.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2009
Resolved 20 January 2009
Resolution: Completed satisfactory COI exam.
Construction/Loadline
Issued 29 March 1985 Resolved
REPAIR THE FOUR WELD FRACTURES IN THE STERN COMPARTMENT.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
FAIR THE DEEP NOTCH IN WAY OF THE STARBOARD SHAFT HOUSING IN THE STERN COMPARTMENT.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
REWELD THE BAD WELDMENT AROUND THE HOUSING FOR HTE PORT SHAFT IN THE STERN COMPARTMENT.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Electrical
Issued 29 March 1985 Resolved
REMOVE THE EXTENSION CORD TYPE ELECTRICAL WIRING IN THE MACHINERY SPACE.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Engineering
Issued 29 March 1985 Resolved
PERMANENTLY PIPE THE BALLAST SYSTEM WITH RIGID PIPING. FLEXIBLE RIGID HOSEMAY BE ALLOWED AT ONE POINT IN THE SYSTEM.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Unknown
Issued 19 March 1984 Resolved
REPLACE ELECTRICAL COVER ON JUNCTION BOX FOR REEFER UNIT
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984
Unknown
Issued 19 March 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE SUNSHINE II, DN526145
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984
Unknown
Issued 19 March 1984 Resolved
MAKE BULKHEAD BETWEEN ENGINE ROOM AND QUARTERS BILGES WATERTIGHT IN WAY OF THE NEWLY INSTALLED AIR LINES
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984
Unknown
Issued 19 March 1984 Resolved
ELIMINATE EXCESSIVE PLAY AT THE CONNECTION OF THE STEERING GEAR RAM AND JOCKEY BAR
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984
Unknown
Issued 19 March 1984 Resolved
REMOVE BOLT AND WELD HOLE IN AFT BULKHEAD
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984
Unknown
Issued 19 March 1984 Resolved
REPAIR MINOR FRACTURES IN AFT STEERING ROOM
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984

Casualty record · 1

1 August 2018Routine · role: Involved in a Marine Casualty · activity 6498322
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MAVERICK (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.