Records from 2010 to 2026. Most recent: inspection, 20 May 2026.
Inspection history · 25
20 May 2026
Examination of Repairs · Administrative Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8377464
18 July 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8188701
16 May 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8139536
8 May 2025
Deficiency Check · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8130939
30 October 2024
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8027151
7 August 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7976489
8 June 2023
Annual Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7709689
26 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7696979
10 May 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7685592
2 August 2022
Administrative Inspection · Examination of Repairs · In-Service Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7523002
12 October 2021
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7283631
3 March 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7157069
26 February 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7146864
26 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7084090
24 September 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7064084
9 September 2019
Deficiency Check · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6807511
6 August 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6827589
12 October 2018
Annual Inspection · Damage Survey · Plan Review "T" Boat · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6560024
26 September 2018
Internal Structural Exam · Examination of Repairs · In-Service Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6549448
6 August 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6502533
1 August 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6498322
12 March 2018
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6370336
13 October 2017
Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6261140
1 December 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6045119
21 September 2016
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5999723
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2025
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 65 feet in length must carry a minimum of three ring life buoys. At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet, securing the waterlight around the body of the ring life buoy. The name of the vessel must be marked or painted in clearly legible letters and numbers: clearly legible block capital letters with the vessel's name. Each ring life buoy must be marked with Type II retroreflective material in accordance with 46 CFR 185.604. Vessel is fitted with three buoys; the port bow buoy has a waterlight incorrectly attached and lacks markings, including approval standard per 46 CFR 160.050. The starboard bow buoy requires retroreflective material and markings, and the aft buoy requires approval per 46 CFR 160.050.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 17 September 2025
Resolution: Owner/Operator purchase new ring buoys with appropriate markings and fittings.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 August 2025
Resolved
Each disposable hydrostatic release unit (HRU) must be marked with an expiration date of two years after the date on which the unit is installed. The EPIRB was marked for three years, and was found to be expired. Vessel operator had a new HRU available.
46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2025
Resolved 4 September 2025
Resolution: Vessel installed a new HRU for their EPRIB.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 August 2025
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: Charts of large enough
scale to make safe navigation possible. Vessel's crew
was not able to verify up-to-date electronic charts.
46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2025
Resolved 17 September 2025
Resolution: Capt emailed a photo of the Garmin specs/software update. MI verified latest software system.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 1 July 2025
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited. Acceptable methods of securing the device include— Closing the seacock and removing the handle;(2) Padlocking the seacock in the closed position;(3) Using a non-releasable wire-tie to hold the seacock in the closed position; or(4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock. Piping appears to be configured to bypass MSD tank and was missing required securing devices. Discharge piping was wasted and fractured. Rectify to the satisfaction of the MI.
46 CFR 184.704
33 CFR 159.7(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 16 July 2025
Resolution: Discharge piping replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 September 2024
Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and
other spaces to see that there is no accumulation
of oil or other matter which might create a fire hazard.
Observed excessive oil in the bilges under the main engine. Remove and clean to the satisfaction of attending marine inspector. 46 CFR 176.25-50(b)(Old T)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 September 2024
Resolution: Excess oily water removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 September 2024
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Vessel's fixed bilge system was inoperable and unable to drain water from spaces. Correct to the satisfaction of attending marine inspector. 46 CFR 182.25-1(a)(Old T)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 September 2024
Resolution: Fixed bilge pump replaced and operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2024
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. In the crew accommodation space there are two penetrations aft port, one forward port, and two aft starboard that are not watertight. Correct to the satisfaction of USCG marine inspector. 46 CFR 177.13-1(Old T)
46 CFR 171.114(a)(2)(Old S)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 6 September 2024
Resolution: Pentrations corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2024
Resolved
The cockpit must be watertight. There are two leaks, port and starboard, in way of the companionway decks outboard of crew accommodations that are leaking into the voids below deck. Correct to the satisfaction of the USCG marine inspector. 46 CFR 177.13-1(Old T) 46 CFR 171.145(a)(Old S)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 6 September 2024
Resolution: Leak repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2024
Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. Where the internals of the vessel are completely concealed, sections of the lining or ceiling may be removed or the parts otherwise probed or exposed
so that the marine inspector may satisfy himself as to the condition of the hull structure. Vessel had two leaks in deck bulk head of the Tool Room and one leak through the deck bulkhead of the forepeak void through the deteriated windlass. Correct to the satisfaction of the USCG marine inspector. 46 CFR 176.25-5(a)(1)(Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 6 September 2024
Resolution: Leaks repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2024
Resolved
Water for cooling the exhaust pipe must be obtained from the engine cooling water system or a separate engine driven pump. The center and starboard main engines are being primed via a garden hose attached to a water tank. Correct to the satisfaction of USCG marine inspector. 46 CFR 182.425 (b)(1)(Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2024
Resolved 30 October 2024
Resolution: Vessel installed new sea valve. Engine cooling systems working properly.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 September 2024
Resolved
All vessels with crew members living on board shall be provided with crew accommodations of sufficient
size, adequate construction, and with suitable equipment to provide for the protection and accommodation of the
crew in a manner practicable for the size, facilities, and service of the vessel. Bolt was missing on the the plate for the strap down of the refrigerator. Correct to the satisfaction of USCG marine inspector. 46 CFR 177.25-1(a)(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2024
Resolved 6 September 2024
Resolution: Bolt replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 7 August 2024
Resolved
No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate license or officer endorsement on his or her MMC. Master was unable to provide medical certificate and submittal documentation. Master to provide documentation prior to operating vessel to the satisfaction of USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2024
Resolved 6 September 2024
Resolution: Medical certificate documentation provided.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 June 2023
Resolved
The master shall conduct sufficient drills and give
sufficient instructions to make sure that all crew
mem]trers are familiar with their duties during
emergencr es that necessitate abandoning ship or the
recovery of persons who have fallen overboard. MOB
drills need to be conducted to satisfaction of
lnspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2023
Resolved 1 August 2023
Resolution: Vessel crew conducted drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2023
Resolved
A vessel must be provi ded with a satisfactory
arrangement for draining any watertight compartment,
other than small buoyancy compartments, under all
practicable conditions. Sluice valves are not permitted
in watertight bulkheads. Conduct complete test of bilge
suction system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2023
Resolved 1 August 2023
Resolution: Tested all suctions.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 June 2023
Resolved
Each survival craft must be (1) Secured to the vessel
by a paln ter with a ffoat-free link permanently attached
to the vessel except that a float-free link is not
required if the vessel- operates only on water
deep as the length of the painter HRU was improperly
installed and needs to be installed properly to
satisfaction of inspector.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 August 2023
Resolved 1 August 2023
Resolution: HRU correctly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 June 2023
Resolved
Vessel must carry one floating waterlight, unless it is
limited to daytime operation, in which case no floating
waterlight is required. Each floating waterlight
installed after March 11, 1997, on a wessel carrying
only one ring buoy, must be attached to the lanyard with
a corrosion-resistant clip. The clip must hawe a
strength of at least 22.1 ktLograms (50 pounds), and
affow the waterlight to be quickly disconnected from the
ring life buoy. Floating fight was not properly
installed to buoy. Needs to be installed properly to the
satisfaction of inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2023
Resolved 1 August 2023
Resolution: Installed Properly.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 October 2021
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Noted a buckled frame on the port side while conducting internal structural exam in the forepeak space. In addition, noted inset on the starboard bow approximately 2 feet wide and 2 inches deep. prepare repair proposal and complete repair to the satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 9 November 2021
Resolution: Port and starboard bow inserts were satisfactorily welded and attending marine inspector witnessed satisfactory pressure test for each
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 12 October 2021
Resolved
The marine inspector shall examine the bilges to see that there is no accumulation of oil. Noted oily water accumulation in engine room and steering room in the bilge. Clean bilges to satisfaction of marine inspector. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 8 November 2021
Resolution: Bilges were cleaned and inspected satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
The marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service intended. Noted multiple electrical outlets that were in an open ground and hot/neutral rev condition, and daisy chaining multi-outlet connectors. Repair to correct status. 46 CFR 176.25-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 27 October 2021
Resolution: Electrical outlets were rewired and tested satisfactory with a socket tester; all outlets were found in the correct indication.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 October 2021
Resolved
On a vessel of more than 65 ft in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accomodation spaces and all other spaces normally manned by crew members. No overnight passengers until rectified.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 8 November 2021
Resolution: Public address system was tested operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2021
Resolved
Fuel tank vent pipes must be fitted with removable flame screens. Noted the flame screens for fuel tank vent pipes were clogged. Repair or replace flame screens.
Vessel rep informed Marine inspector that the portside fuel ventilation goose-neck piping had sheered off when attempting to replace the flame screen. Provide a repair proposal and repair or replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2021
Resolution: Repaired portside fuel tank goose-neck piping and replaced flamescreen
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 October 2021
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and a float-free link. Inflatable liferaft installed as a substitute for life float or buoyant apparatus as allowed by 180.10-30(c) was only secured by a hydrostatic release unit. Crew was educated on proper inflatable life raft stowage and painter was attached to vessel on the spot.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2021
Resolved 12 October 2021
Resolution: Crew educated, painter attached to bracket on ship.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 October 2021
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear." Doors on either side of the accompdation space and overhead hatches in the generator room and engine room require proper labeling. 46 CFR 185.30-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 8 November 2021
Resolution: Emergency exits were labled accordingly
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 October 2021
Resolved
A vesel must carry either a first-aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kits onboard are missing multiple required items including ammonia inhalants, iodine applicators, tourniquet, and eye dressing. Replace all missing items to make a complete kit as required by 160.041.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 8 November 2021
Resolution: All required first aid items were verified onboard and within expiration
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 October 2021
Resolved
All vessels over 26 feet in length shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Engine workshop has 2 suction points due to centerline fuel tanks preventing communication from one side of the bilge to the other. Starboard side pickup could not be proven functional. Repair and demonstrate functionality. Lazarette pickup also needs to be tested in presence of USCG. 46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 8 November 2021
Resolution: Bilge system tested operational
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 5 November 2020
Resolved
Vessels operated more than 100 NM but not more than 200NM from the nearest land, be equipped with a NAVTEX receiver conforming to the following performing standards. Vessel is restricted to 100NM until radio installation meets marine inspector satisfaction. Vessel is not equipped with NAVTEX printing capability or approved alternative.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 1 December 2020
Resolution: Vessel installed NAVTEX receiver on vessel and sent confirmation photo.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 October 2020
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release is missing expiration date. Vessel is limited to carry 25 passengers until def is rectified.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 20 November 2020
Resolution: Vessel sent photo of hydrostatic release correctly labeled with servicing certificate
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2019
Resolved
Fire fighting equipment and appliances- all vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. Vessel could not provide a portable hand fire pump. 46 CFR 181.10-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2019
Resolved 18 September 2019
Resolution: Vessel operator provided the pump from the vessels storage warehouse.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2019
Resolved
Other structural condition- Except for engine exhausts each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 6 inches above the deepest subdivision load line must have means to prevent water from entering the vessel if pipe fractures or otherwise fails. Overboard discharge piping for forward shower has no means to secure or prevent the flow of water in. At vessels deepest draft discharge is within 6 inches of waterline. 46 CFR 171.119 (b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2019
Resolved 28 October 2019
Resolution: Crew installed a valve on the overboard discharge and a check valve to prevent back flooding if the vessel's load causes water ingress.
Communications › Radio Communications › EPIRB
Issued 13 October 2017
Resolved
Route restricted to less than 3NM from shore. The EPIRB hydrostatic release unit has expired. Each expired life saving item shall be replaced during the annual inspection. Replace the EPIRB hydrostatic release.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 18 October 2017
Resolution: Replaced EPIRB HRU and correctly labelled expiration date on the new unit.
Engineering › Fuel Oil Service System › Valve
Issued 13 October 2017
Resolved
Fuel shutoff valves were labelled improperly. Remote fuel shutoff valves must be labelled with direction of operation. Correctly label shutoff valves.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 18 October 2017
Resolution: Switched direction of operation.