MAURY USCG vessel records Sign in
← All vessels

ICE GRACE

ICE GRACE is a 1988 freight ship. The Coast Guard has recorded 36 inspections since 1988, most recently in March 2026, along with 18 deficiencies and 5 operational controls.

Records from 1988 to 2026. Most recent: inspection, 12 March 2026.

Built
1988
Last inspected
12 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8706777 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
322293
Flag
BAHAMAS, THE
—
Maury page id
psix-322293

Inspections, by type

…with no type recorded17
Years with a record 23 calendar years (1988–2026)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it7984 - Simplified, Net Ton
12348 - Simplified, Gross Ton
12348 - Convention (Subpart B), Gross Ton
14932 - Dead Weight, Metric Ton
7984 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LINDSEY Towing Vessel · MISLE 340991 · 28 February 2016 · activity 5824169SONIE Towing Vessel · MISLE 820201 · 28 February 2016 · activity 5824169

Inspection history · 36

12 March 2026 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8324939
11 July 2025 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8167406
1 July 2025 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8182705
30 May 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8148099
25 November 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039511
21 March 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7882991
15 February 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7865866
12 February 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7864133
9 March 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648211
1 February 2023 PSC B · ISM Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7630190
28 February 2022 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7402957
2 April 2021 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7166055
19 May 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6955857
4 March 2019 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6635781
1 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5828466
29 February 2016 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5823690
28 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5823389
28 February 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5824169
4 March 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4810000
11 February 2012 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4240038
6 January 2012 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4218755
26 January 2011 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3933328
28 January 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3671609
27 January 2010 NPV Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3670722
6 July 2009 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3526079
22 December 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3383687
19 December 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3382881
15 November 2008 PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3360530
12 March 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275718
12 February 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 425680
18 January 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 715218
28 December 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 386322
28 January 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355952
23 January 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 341490
19 November 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 333934
12 December 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 327302

Deficiency record · 18

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 February 2023 Resolved
In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with it’s possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Objective evidence discovered during an expanded ISM exam revealed that the vessel failed to properly inspect and maintain critical fire safety appliances including fixed fire detection, fire doors, and fire extinguishers. Additionally, these long-standing non-conformities have not been properly reported or addressed in accordance with the vessel’s safety management system. An external third party audit is required. 74SOLAS(2) IX/3.1; ISM Code 10.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 February 2023
Resolution: Received ISM Audit Report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 February 2023 Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. PSCO observed four fire detectors in the engine room with rags secured around them and one that was dismantled rendering them unavailable for immediate operation. Four additional detectors have been inoperable since October 2022. 74SOLAS(97) II-2/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 February 2023
Resolution: Received LR class report attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 February 2023 Resolved
The fire resistance of doors, shall, as far as practicable, be equivalent to that of the division in which they are fitted. PSCO observed numerous fire doors throughout engine room and accommodation space with holes, cracks, and missing closure devices.74 SOLAS (97) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2023
Resolution: Received LR Class report attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 February 2023 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed multiple extinguishers throughout the engine room and accommodation spaces with worn hoses becoming detached from the extinguisher. 74SOLAS(97)II-2/20.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2023
Resolution: Received LR Class report attesting to the condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2023 Resolved
The purpose of this chapter is to require the fullest practicable degree of fire protection, fire detection and fire extinction in ships. PSCO observed oil soaked rags stuffed behind high pressure fuel pumps on main engine. 74SOLAS(97)II-2/2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2023
Resolution: Crew members removed oil soaked rags from the behind the main engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 February 2022 Resolved
All valves and shell fittings required by the regulation shall be of steel, bronze or other suitable material. Valves of ordinary cast iron or similar material are not acceptable. All pipes to which types of regulation refers shall be of steel or other equivalent material to the satisfaction of the administration. PSCO observed soft patching on pipes inboard of valves. SOV-2 and ADV-8 in the engine room.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2022
Resolution: To the satisfaction of RO/RSO. Received class report attesting to permanent repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 2 April 2021 Resolved
A ship must have a placard of at least 5 by 8 inches, made of a durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: Discharge of oil Prohibited. The Federal Water Pollution Control Act prohibits the discharg eof oil into or upon the navigable waters of the United States (...). Vessel did not have any placard regarding the discharge of oil being prohibited.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2021
Resolution: Vessel provided satisfactory evidence (pictures) that deficiency was rectified. Pictures saved in Documents tab.
Engineering › Compressed Air System (control) › Valve
Issued 29 February 2016 Resolved
74 SOLAS (14) 1/11(c): M/V ICE GRACE suffered a loss of propulsion on the main diesel engine on 01MAR16. Recommend class attend and submit report outlining cause of the loss of propulsion and corrective measures to be taken for repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2016
Resolved 2 March 2016
Resolution: Reviewed attached class report from Lloyds Register. Class report outlining cause, effected repairs, and future preventative measures are determined satisfactory by Coast Guard Port State Control. Form B is lifted.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 February 2016 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. The vessel suffered a loss of propulsion when attempting to shift from ahead propulsion to astern propulsion. 74 SOLAS (14 cons.) I/11; Prior to Movement
Action required: 705 - Other - as specified
Resolved 3 March 2016
Resolution: Recieved and accepted the class report. Class tested and accepted repair/cleaning which was completed on a start air valve. Demonstrated proper operations.
Engineering › Fuel Oil Service System › Piping
Issued 28 January 2010 Resolved
0830 - Pipes wires (insulate) - Steam leak observed at bunker tank return line in engine room at forward bulkhead. Steam line needs to be repaired and maintained to prevent injury to crewmembers. SOLAS 04 Cons. Ch 2-1 Reg 26.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 29 January 2010
Resolution: Class survey completed and attested to repairs. Survey reviewed by CG and deemed satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2010 Resolved
0950 - Electric equipment in general. Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame retarding, and where necessary fire-resisting properties of the cable. Electrical wiring for installed engineering alarm, main engine fuel oil filter and dead end wire at port side forward overboard valve improper. Solas 74 Ch 2-1 Reg 27
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 31 March 2010
Resolution: PSCO observed the "dead end" wiring for the engineering alarm, main engine fuel oil filter have been capped off and covered with electrical tape.
Fire Fighting › Fire Hydrants › Condition
Issued 28 January 2010 Resolved
0720 - Fire fighting equipment. Fire extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. Fire station #19 was leaking water at the valve. Solas 74 Ch 2-2 Reg 15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 31 March 2010
Resolution: VSL connected a fire hose to fire station #19 and activated the main fire pump. PSCO witnessed adequate pressure in the system and no leaking was observed at the valve.
Construction/Loadline › Hull › Side Shell
Issued 27 January 2010 Resolved
0938- Hull damage impairing seaworthiness - Approximately 14x2" crack in forward peak tank below the water line and just aft the bulbous bow. The administration shall satisfy in self that the general structural strength of the hull is sufficient for the draught corresponding to assigned freeboard.- ICLL 2005 Cons annex1 ch.1 reg.1 - 17(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 29 January 2010
Resolution: Received class report attesting to repairs.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 27 January 2010 Resolved
1199- Other Cargo - Vessel needs to have oil transfer procedures for all oil transfer operations. Vessel did not have transfer procedures for lube oil transfer available. - 33 CFR 156.120 (t)(2) - 70(c)
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 31 March 2010
Resolution: Chief Engineer provided PSCO with a copy of Oil Transfer Procedures specific to the M/V PARANA
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 15 November 2008 Resolved
MSD plant (Sewage) has the two following repairs that have not been approved by class: 1) Soft-Patch in pipeline leaping into tank, Tanktop 2) Tank top has been cut and Riveted and possibly comprimises the inner lining. (SOLAS 2004 Ch. I Reg. 2)
Action required: 705 - Other - as specified
Due 15 December 2008
Resolved 22 December 2008
Resolution: Recieved class report attesting to repairs of to MSD.
Engineering › Lubricating Oil Service System › Purifier
Issued 15 November 2008 Resolved
#3 SSDG has excessive F/O leak near the F/O Strainers. This oil leak creates a fire hazard in the engine room. (SOLAS 2004 Ch. I Reg.2)
Action required: 705 - Other - as specified
Due 15 December 2008
Resolved 22 December 2008
Resolution: Recieved class report attesting to repairs of leaking FO from generator.
Navigation
Issued 28 December 1995 Resolved
THE VESSELS B/A CHARTS 1082, 899 AND 1063 WERE MISSING VARIOUS CORRECTIONS THE VESSEL WAS INSTRUCTED TO CORRECT THE CHARTS PRIOR TO DEPARTING.
Condition: Unknown
Due 28 December 1995
Resolved 28 December 1995
Navigation
Issued 12 December 1988 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART 12304 ORIT'S ACCEPTABLE FOREIGN EQUIVALENT WHICH WAS REQ. FOR THE VSL'S ROUTE FROM CAPE HENLOPEN TO ARNOLD'S POINT.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.