Records from 2016 to 2022. Most recent: inspection, 14 December 2022.
Inspection history · 18
14 December 2022
In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7604339
24 June 2022
Drydock Exam · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7485700
3 June 2021
COI Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7213427
1 June 2021
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7212183
27 November 2020
Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7103365
14 July 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7006044
9 June 2020
Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6971833
24 October 2019
Internal Structural Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6840852
1 July 2019
DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6727363
30 May 2018
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6728666
30 April 2018
Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6728673
1 February 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6352057
25 January 2018
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6343449
10 November 2017
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6309050
25 October 2017
In-Service Inspection · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6295195
29 June 2017
Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6214107
17 May 2017
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6166104
18 April 2016
DAPI Audit · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5856906
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 February 2023
Resolved
Subpart E- Re-inspection Annual inspection. Your vessel must undergo an annual inspection within three months before or after each anniversary date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2024
Resolution: Vessel has entered into Laid Up status.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 December 2022
Resolved
Upon completion of repairs during dry dock, an underway sea trial is to be conducted to the satisfaction of the attending Coast Guard Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2024
Resolution: Vessel has entered into Laid Up status.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2022
Resolved
Non metallic exhaust hoses may be used, provided it is especially adapted to resist the action of collapsing or panting, and is doubled clamped where practicable. Replace both port and starboard exhaust hoses which have collapsed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2024
Resolution: Vessel has entered into Laid Up status.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 December 2022
Resolved
Unless otherwise specified, vessel owners must pay the fees required before inspection services are provided. Provide documentation of payment to www.pay.gov.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2024
Resolution: Vessel has entered into Laid Up status.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022
Resolved
Remove dead end wiring above Fire boy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022
Resolved 29 November 2022
Resolution: Dead end wiring has been removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 June 2022
Resolved
Label F/O shut off.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022
Resolved 16 July 2024
Resolution: Vessel has entered into Laid Up status.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 29 June 2022
Resolved
Remount/ reinstall Aft railing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022
Resolved 4 December 2022
Resolution: Installed aft railing to satisfaction of attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 June 2022
Resolved
Topside helm is air bound and does not currently work.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2022
Resolved 4 December 2022
Resolution: Bled steering system, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 June 2022
Resolved
Gauges to indicate engine cooling water discharge temp. shall be provided. Gauge doesn't work.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 16 July 2024
Resolution: Vessel has entered into Laid Up status.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2021
Resolved
An adult life jacket must be provided for each person carried onboard a vessel. Vessel is missing 03 life jackets. Number of passengers will be lowered to 43 until the deficiency is cleared.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 21 July 2021
Resolution: New life jackets have been purchased.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 June 2021
Resolved
The master and crew of a vessel will be familiar with the content of, and have mounted at the operating station, the emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel is missing emergency instructions.
46 CFR 180.510(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 21 July 2021
Resolution: Emergency instructions have been made and posted
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 June 2021
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Install placard locating fire extinguisher on bridge.
46 CFR 181.520
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 2 July 2021
Resolution: placard has been added
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2021
Resolved
Each child-sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so that the child-sized life jackets are not mistaken for adult life jackets. Vessel needs to label life jackets correctly.
46 CFR 180.78(a)(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 2 July 2021
Resolution: placard has been added to vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 June 2021
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up to date: charts, US coast Pilot or similar publication, CG light list, tide tables, and current tables. Vessel needs to update all their charts and publications.
46 CFR 184.420(a)(1)-(5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 2 July 2021
Resolution: Updated charts and publications have been placed on board
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 June 2021
Resolved
Fireboy system discharged, cause unknown.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2021
Resolution: Fireboy replaced, with a "old" one, inspected 1JUN2021. New one on order. The discharge occured when the ampule was cracked while cleaning and slowly drained out.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 July 2020
Resolved
Fixed fire fighting system was not within it's annual maintenace requirement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 27 November 2020
Resolution: All extingushers portable and ffixed have been serviced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 July 2020
Resolved
Required number of portable fire extinguishers not present.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 27 November 2020
Resolution: 3 portables and the fixed E/R extinguishers were on station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2020
Resolved
Ring life buoy deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 27 November 2020
Resolution: Lifering had been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 July 2020
Resolved
Vessel did not have required first aid kit supplies.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 27 November 2020
Resolution: New first aid kit was onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2019
Resolved
Vessel had leaks in the vicinity of the port and starboard turbo.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2019
Resolved 2 July 2019
Resolution: Resolved.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 July 2019
Resolved
Areas around the engine room hatch cover and surrounding beams need replacing. Deferred until next drydock or earliest opportunity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 9 June 2020
Resolution: Verified that E/R hatch combing had been repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 July 2019
Resolved
Remove dead end wiring.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 31 July 2019
Resolved 2 July 2019
Resolution: Removed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 July 2019
Resolved
Vessel had two buoyant apparatus instead of life floats. They were removed from the vessel and the vessel is restricted to 3nm until correct installation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 July 2019
Resolved 9 June 2020
Resolution: Verified bouyant apparatus was removed. Vessel COI ammended to reflect limit of 3nm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019
Resolved
Vessel had several defective PFD's that required replacing and several that needed retro reflective tape added.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 31 July 2019
Resolved 2 July 2019
Resolution: Replaced and repaired.
Stability › Watertight Integrity › General
Issued 18 April 2016
Resolved
Provide working aft hatch gasket.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 19 May 2016
Resolution: New gasket installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 18 April 2016
Resolved
Make state registration number on starboard side readable.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 19 May 2016
Resolution: New registration numbers placed on starboard side hull.
Documentation › Certificates/Documents › Stability Letter
Issued 18 April 2016
Resolved
Provide latest stability on board vessel.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 19 May 2016
Resolution: Stability letter paper work provided.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 April 2016
Resolved
Make forward bulkhead penetrations watertight. Engine compartment looking forward.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 19 May 2016
Resolution: Forward bulkhead penetrations watertight.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 18 April 2016
Resolved
Make all guages at upper and lower helm operational.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 19 May 2016
Resolution: New sending units and guages installed.