SHOGUN

SHOGUN is a 1989 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 2016, most recently in January 2026, along with 45 deficiencies and 3 casualty investigations between 2006 and 2014.

Records from 2006 to 2026. Most recent: inspection, 27 January 2026.

Built
1989
Last inspected
27 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDC4322
328818
Flag
UNITED STATES
Maury page id
psix-328818

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded5
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)80.8 ft × 28.0 ft × 7.1 ft
Registered tonnagegross 99 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLO PRESTE-DUNN BOAT YARD · CHULA VISTA, CA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 40

27 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8302528
30 October 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8260857
8 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108124
31 January 2025 Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8072947
4 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7891967
20 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7867561
24 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789659
17 April 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670502
20 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7653479
31 January 2023 Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629475
7 November 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7590492
28 June 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489915
29 March 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504007
7 March 2022 MTSA/ISPS Verification · COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7403382
28 January 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7387163
24 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319876
19 March 2021 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7159356
16 February 2021 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7141214
25 September 2020 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7065322
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7112505
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126943
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126948
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126951
31 July 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7021157
24 March 2020 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930946
13 February 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6908436
19 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6837713
1 April 2019 Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6632180
27 February 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6633772
24 November 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596599
10 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6536891
14 March 2018 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372081
7 March 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6367580
10 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6286167
6 April 2017 Inclining Experiment · Administrative Inspection · Deadweight Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128975
25 January 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6076982
20 January 2017 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6074315
2 December 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6051728
20 January 2016 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800749
15 January 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5798148

Deficiency record · 45

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2025 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Vessel did not have approved marine type strainer installed. Cite: 46 CFR 182.455(b)(6).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2025
Resolution: Received satisfactory evidence of marine grade filters installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was five short of the required amount of adult life jackets at the time of the inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2024 Resolved
Electrical equipment o/b vessel must be installed and maintained to protect passengers, crew and other persons and the vessel from electrical hazards. Following electrical safety infractions during exam: -Must mount break switches for pump systems in engine switchboard. -Must mount junction box located in port aft accom space closet. -Must provide cover for electrical outlet in port aft accom space closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2024
Resolved 25 April 2024
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the fire extinguisher securely in it's stowage location. Must provide and mount suitable bracket for fire extinguisher in engine space capable of quick release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 25 April 2024
Resolution: Corrected
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 April 2024 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly and logged. Logs for monthly EPIRB tests not available for inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 February 2024 Resolved
Grind out suspected crack weld where keel meets hull plating, aft / stbd. Submit repair proposal once area is grinded out.
Action required: 705 - Other - as specified
Resolved 27 February 2024
Resolution: Area in question was ground out, drill stopped, and re-welded.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 March 2023 Resolved
Both life rafts that were recently serviced is not properly attached from its pendant to its hydrostatic release unit. Make proper arrangements and secure.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 20 March 2023
Resolution: Corrected & verified by USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023 Resolved
Insulation around both main and generator turbochargers found to be missing. Provide approved insulation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
Unprotected electrical wire found above port generator; Remove or terminate into junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
AFT bathroom overhead electrical receptacle outlet loose and properly secured. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
Main deck at bow centerline light fixture next to life ring missing diffuser. Repair
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
Fore peak light fixture missing bulb, diffuser, and not properly mounted. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
01 Deck aft near life ring buoy center light fixture missing bulb & diffuser. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2023 Resolved
01 Deck life ring buoys name stencil peeling; Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 March 2023 Resolved
Provide plan proposal for installation of stairs in Aft Passenger cabin to aid in means of Escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Vessel met requirements of IFR
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 March 2022 Resolved
Two vessel masters were missing STCW endorsements (one medical and one MMC). Present evidence of sufficiently licensed crewmembers. This is to be rectified prior to sailing foreign. Cite: I/9.3 and I/2.11.
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: Vessel is no longer on a SOLAS route, so the deficiency no longer applies.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 March 2022 Resolved
Provide FCC Marine Radio Operator Permits for all licensed crewmembers. Cite: 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2022
Resolved 28 June 2022
Resolution: Received an email with scans of the crews' newly acquired FCC Marine Radio Operator Permits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2022 Resolved
Properly secure fwd berthing bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 30 March 2022
Resolution: Received email with picture of corrected bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2020 Resolved
Correct the following electrical items: Identify load for breaker #7 on bridge panel. Replace 16 AWG wire for produce box Splice found at produce box. Install into a junction box Correct circuit breaker or cabling IAW produce box
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: Electrical issues addressed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2020 Resolved
Port side battery box must be secured to ship to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: verified battery box secured properly
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 24 March 2020 Resolved
Replace 02 missing light covers in galley and engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: covers replaced
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 24 March 2020 Resolved
Secure port side auxillary pump to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: verified pump secured
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 24 March 2020 Resolved
Conduct drills in presence of Marine Inspectors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2020
Resolution: Drill log verified in lieu of performing drills
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 October 2019 Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation duct from galley. Diesel soaked rags/sorbents in open plastic bucket found in E/R (corrected on the spot).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Fire hazards removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 October 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations below deck. Vessel did not have lighting at the aft emergency exit hatch in stateroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: E. light added and tested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 October 2019 Resolved
Each hatch used as a means of escape must be obvious and rapid to open in an emergency. Mark emergency escape in aft stateroom with easy to understand instructions for opening water tight hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Signage added.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2019 Resolved
Complete & simple instructions for the operation of the E/R CO2 system must be located at each pull box. Properly label instructions for system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Instructions added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Correct the following found: 1) Motor control electrical connection on purifier. 2) Clean excessive dust/debris from inside breaker panels. 3) Attach face-plates/covers on outlets/j-boxes in aft passenger accommodation overhead and crew bunk area. 4) Mount hanging J-box in crew accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 31 July 2020
Resolution: AC 1-line verified and stamped by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 April 2019 Resolved
Provide machinary guards for exposed moving machinary on generators.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 4 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 April 2019 Resolved
Re-label breaker box in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 4 April 2019
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 1 April 2019 Resolved
Replace and/or clean flame screens on fuel vents.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 4 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 April 2019 Resolved
Provide up-to-date navigation charts.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 4 April 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 April 2019 Resolved
All vessel masters must review SMS plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 4 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2019 Resolved
Repair port and starboard fuel shut offs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS.
Lifesaving › Lifebuoys › Serviceable
Issued 20 March 2018 Resolved
Install retro-reflective material and vessel name on forward lifering buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: Retro-reflective material installed
Communications › Radio Communications › EPIRB
Issued 20 March 2018 Resolved
Provide NOAA registration and decal for EPIRB
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: NOAA registration is onboard the vessel and decal properly place on the EPIRB
Engineering › Fuel Oil Service System › Filter
Issued 20 March 2018 Resolved
Remove plastic fuel filter on the fuel transfer piper or install correct filter
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: The plastic filter was removed.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 20 March 2018 Resolved
Remove electrical hazard on electric box in engine room stbd side
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: The hazard was eliminated.
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 10 October 2017 Resolved
Prove proper operation of port engine gear box.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 7 February 2017 Resolved
Prove proper operation of all radio equipment. Send copy of FCC Safety Certificate to attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2017
Resolved 8 February 2017
Fire Fighting › Fire Pumps › Pressure
Issued 7 February 2017 Resolved
Provide working pressure gauge for fire pump.
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 7 March 2017
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 2 December 2016 Resolved
Provide plans for engineering, electrical and manufacturers installation for main engine propulsion control.
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 23 January 2017
Resolution: Vessel rep submitted drawings. All sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 January 2016 Resolved
Properly install distribution panel for electrical system in fwd engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 17 May 2016
Resolution: The panel was replaced.

Casualty record · 3

28 November 2006Routine · role: Transiting Vicinity of Primary Subject · 1 injured · activity 2831539
8 July 2012Routine · role: Involved in a Marine Casualty · activity 4372125
24 June 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4900742
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.