MAURY USCG vessel records Sign in
← All vessels

SHOGUN

SHOGUN is a 1989 passenger vessel (inspected). The Coast Guard has recorded 135 inspections since 1989, most recently in January 2026, along with 138 deficiencies and 3 casualty investigations between 2006 and 2014.

Records from 1989 to 2026. Most recent: inspection, 27 January 2026.

Built
1989
Last inspected
27 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC4322
328818
Flag
UNITED STATES
368453000
Maury page id
psix-328818

Inspections, by type

…with no type recorded21
Years with a record 37 calendar years (1989–2026)
The 135 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.8 ft × 28.0 ft × 7.1 ft
Registered tonnagegross 99 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLO PRESTE-DUNN BOAT YARD · CHULA VISTA, CA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC4322MMSI 368453000 · active · compulsorily equipped · granted 11 January 2025, expires 8 March 2035
WCD7849MMSI not assigned · expired · compulsorily equipped · granted 14 February 1994, cancelled 25 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PACIFICA Passenger (Inspected) · MISLE 49755 · 24 June 2014 · activity 4900742

Inspection history · 135

27 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8302528
30 October 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8260857
8 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108124
31 January 2025 Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8072947
4 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7891967
20 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7867561
24 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789659
17 April 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670502
20 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7653479
31 January 2023 Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629475
7 November 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7590492
28 June 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489915
29 March 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504007
7 March 2022 MTSA/ISPS Verification · COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7403382
28 January 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7387163
24 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319876
19 March 2021 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7159356
16 February 2021 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7141214
25 September 2020 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7065322
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7112505
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126943
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126948
24 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126951
31 July 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7021157
24 March 2020 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930946
13 February 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6908436
19 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6837713
1 April 2019 Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6632180
27 February 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6633772
24 November 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596599
10 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6536891
14 March 2018 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372081
7 March 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6367580
10 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6286167
6 April 2017 Inclining Experiment · Administrative Inspection · Deadweight Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128975
25 January 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6076982
20 January 2017 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6074315
2 December 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6051728
20 January 2016 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800749
15 January 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5798148
2 October 2015 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5734622
24 June 2014 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4900742
24 June 2014 Examination of Repairs · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4901970
12 May 2014 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4856430
8 July 2012 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4371922
8 July 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4372125
7 May 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4304535
8 February 2012 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4215601
16 December 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4209526
23 February 2011 DAPI Audit · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3951207
7 February 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3884285
18 October 2010 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3871847
17 October 2010 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3873706
9 February 2010 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677541
9 February 2010 MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677814
10 March 2009 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3360611
11 February 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3360609
29 April 2008 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3310749
6 March 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3171096
15 February 2008 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3130904
7 February 2008 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3130879
10 December 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3118940
20 February 2007 COI Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2850047
6 February 2007 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2850015
5 June 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2671331
8 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2581728
7 February 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2581071
31 January 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2555743
9 January 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2555732
25 August 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2474423
14 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2334037
10 February 2005 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2272868
18 January 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2272850
14 December 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2259326
7 June 2004 Deficiency Check · MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2091649
20 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2072967
2 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979737
9 December 2003 Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1961418
9 December 2003 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1961441
27 February 2003 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1750474
23 January 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1730875
9 January 2003 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1729609
6 January 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1726334
10 September 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1673607
24 August 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1666536
5 April 2002 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601635
27 February 2002 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1489880
24 January 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1481030
3 January 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1475277
25 December 2001 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473724
25 October 2001 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 772000
3 October 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 668267
9 March 2001 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1061410
23 January 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1057779
5 January 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1470285
24 June 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 34605
11 February 2000 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1046935
20 December 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381761
1 December 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455801
20 August 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 101269
30 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 793036
18 March 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1122800
2 February 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384028
26 January 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408236
9 April 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1424558
4 February 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1433306
2 July 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 121398
8 April 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374957
21 January 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390419
15 April 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1392435
12 December 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1454286
19 May 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1183984
16 February 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1155244
2 February 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398201
4 November 1994 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1359989
8 July 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1463106
18 May 1994 COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 860412
14 December 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1159829
15 June 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153549
19 May 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841604
15 December 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1139796
4 September 1992 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938461
20 May 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1265834
22 May 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 926988
10 January 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 914291
7 September 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1215153
22 May 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235499
2 January 1990 Hull Examination · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1235783
18 November 1989 Permit to Proceed · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 911108
21 September 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1203805
1 August 1989 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195369
29 June 1989 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1207637
2 June 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1031542
1 June 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1348826
26 May 1989 Plan Review "T" Boat · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 971242

Deficiency record · 138

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2025 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Vessel did not have approved marine type strainer installed. Cite: 46 CFR 182.455(b)(6).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2025
Resolution: Received satisfactory evidence of marine grade filters installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was five short of the required amount of adult life jackets at the time of the inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2024 Resolved
Electrical equipment o/b vessel must be installed and maintained to protect passengers, crew and other persons and the vessel from electrical hazards. Following electrical safety infractions during exam: -Must mount break switches for pump systems in engine switchboard. -Must mount junction box located in port aft accom space closet. -Must provide cover for electrical outlet in port aft accom space closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2024
Resolved 25 April 2024
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the fire extinguisher securely in it's stowage location. Must provide and mount suitable bracket for fire extinguisher in engine space capable of quick release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 25 April 2024
Resolution: Corrected
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 April 2024 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly and logged. Logs for monthly EPIRB tests not available for inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 February 2024 Resolved
Grind out suspected crack weld where keel meets hull plating, aft / stbd. Submit repair proposal once area is grinded out.
Action required: 705 - Other - as specified
Resolved 27 February 2024
Resolution: Area in question was ground out, drill stopped, and re-welded.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 March 2023 Resolved
Both life rafts that were recently serviced is not properly attached from its pendant to its hydrostatic release unit. Make proper arrangements and secure.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 20 March 2023
Resolution: Corrected & verified by USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023 Resolved
Insulation around both main and generator turbochargers found to be missing. Provide approved insulation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
Unprotected electrical wire found above port generator; Remove or terminate into junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
AFT bathroom overhead electrical receptacle outlet loose and properly secured. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
Main deck at bow centerline light fixture next to life ring missing diffuser. Repair
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
Fore peak light fixture missing bulb, diffuser, and not properly mounted. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
01 Deck aft near life ring buoy center light fixture missing bulb & diffuser. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2023 Resolved
01 Deck life ring buoys name stencil peeling; Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 March 2023 Resolved
Provide plan proposal for installation of stairs in Aft Passenger cabin to aid in means of Escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Vessel met requirements of IFR
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 March 2022 Resolved
Two vessel masters were missing STCW endorsements (one medical and one MMC). Present evidence of sufficiently licensed crewmembers. This is to be rectified prior to sailing foreign. Cite: I/9.3 and I/2.11.
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: Vessel is no longer on a SOLAS route, so the deficiency no longer applies.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 March 2022 Resolved
Provide FCC Marine Radio Operator Permits for all licensed crewmembers. Cite: 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2022
Resolved 28 June 2022
Resolution: Received an email with scans of the crews' newly acquired FCC Marine Radio Operator Permits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2022 Resolved
Properly secure fwd berthing bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 30 March 2022
Resolution: Received email with picture of corrected bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2020 Resolved
Correct the following electrical items: Identify load for breaker #7 on bridge panel. Replace 16 AWG wire for produce box Splice found at produce box. Install into a junction box Correct circuit breaker or cabling IAW produce box
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: Electrical issues addressed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2020 Resolved
Port side battery box must be secured to ship to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: verified battery box secured properly
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 24 March 2020 Resolved
Replace 02 missing light covers in galley and engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: covers replaced
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 24 March 2020 Resolved
Secure port side auxillary pump to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: verified pump secured
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 24 March 2020 Resolved
Conduct drills in presence of Marine Inspectors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2020
Resolution: Drill log verified in lieu of performing drills
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 October 2019 Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation duct from galley. Diesel soaked rags/sorbents in open plastic bucket found in E/R (corrected on the spot).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Fire hazards removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 October 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations below deck. Vessel did not have lighting at the aft emergency exit hatch in stateroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: E. light added and tested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 October 2019 Resolved
Each hatch used as a means of escape must be obvious and rapid to open in an emergency. Mark emergency escape in aft stateroom with easy to understand instructions for opening water tight hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Signage added.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2019 Resolved
Complete & simple instructions for the operation of the E/R CO2 system must be located at each pull box. Properly label instructions for system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Instructions added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Correct the following found: 1) Motor control electrical connection on purifier. 2) Clean excessive dust/debris from inside breaker panels. 3) Attach face-plates/covers on outlets/j-boxes in aft passenger accommodation overhead and crew bunk area. 4) Mount hanging J-box in crew accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 31 July 2020
Resolution: AC 1-line verified and stamped by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 April 2019 Resolved
Provide machinary guards for exposed moving machinary on generators.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 4 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 April 2019 Resolved
Re-label breaker box in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 4 April 2019
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 1 April 2019 Resolved
Replace and/or clean flame screens on fuel vents.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 4 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 April 2019 Resolved
Provide up-to-date navigation charts.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 4 April 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 April 2019 Resolved
All vessel masters must review SMS plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 4 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2019 Resolved
Repair port and starboard fuel shut offs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS.
Lifesaving › Lifebuoys › Serviceable
Issued 20 March 2018 Resolved
Install retro-reflective material and vessel name on forward lifering buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: Retro-reflective material installed
Communications › Radio Communications › EPIRB
Issued 20 March 2018 Resolved
Provide NOAA registration and decal for EPIRB
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: NOAA registration is onboard the vessel and decal properly place on the EPIRB
Engineering › Fuel Oil Service System › Filter
Issued 20 March 2018 Resolved
Remove plastic fuel filter on the fuel transfer piper or install correct filter
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: The plastic filter was removed.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 20 March 2018 Resolved
Remove electrical hazard on electric box in engine room stbd side
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: The hazard was eliminated.
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 10 October 2017 Resolved
Prove proper operation of port engine gear box.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 7 February 2017 Resolved
Prove proper operation of all radio equipment. Send copy of FCC Safety Certificate to attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2017
Resolved 8 February 2017
Fire Fighting › Fire Pumps › Pressure
Issued 7 February 2017 Resolved
Provide working pressure gauge for fire pump.
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 7 March 2017
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 2 December 2016 Resolved
Provide plans for engineering, electrical and manufacturers installation for main engine propulsion control.
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 23 January 2017
Resolution: Vessel rep submitted drawings. All sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 January 2016 Resolved
Properly install distribution panel for electrical system in fwd engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 17 May 2016
Resolution: The panel was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 2 October 2015 Resolved
Prove proper operation of port MDE prior to carrying passengers
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 7 October 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 24 June 2014 Resolved
Vessel's STBD reduction gear remained engaged when control station lever was placed in to neutral position. Trouble shoot and correct deficiency to the satisfaction of attending MI prior to carrying passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 8 July 2012 Resolved
Make vessel available for machinery/propulsion/systems checks to be witnessed/approved to satisfaction of USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 8 July 2012
Resolved 13 July 2012
Lifesaving › Lifefloat › Not on Board
Issued 8 March 2011 Resolved
All life jackets and lifefloats required under the seasonal limited coatwise route endorsement must be on board and ready for inspection. Vessel restricted to 35 passengers on this route.
Action required: 705 - Other - as specified
Due 11 April 2011
Resolved 5 April 2011
Resolution: At request of [name withheld], Ltd C/W seasonal operating allowance removed from COI.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 March 2011 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 11 April 2011
Resolved 5 April 2011
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2011 Resolved
Update paper charts.
Action required: 705 - Other - as specified
Due 11 April 2011
Resolved 5 April 2011
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 8 March 2011 Resolved
Replace expired SART batteries. Vessel is restricted from International Voyages.
Action required: 705 - Other - as specified
Due 11 April 2011
Resolved 5 April 2011
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 February 2010 Resolved
Provide securing device for MSD within 3 miles of land.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2010
Resolved 3 April 2010
Documentation › Certificates/Documents › FCC SSL
Issued 9 February 2010 Resolved
Provide a radio operators permit for vessels second captain.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2010
Resolved 19 March 2010
Lifesaving › Lifejacket/PFD (Type II) › Lights
Issued 10 March 2009 Resolved
42 life preserver lights INOP. Remove and replace 42 lights. Restricted to less than 20 NM IAW 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: Operator replaced all 33 life vest lights with new lights. Operational check completed on lights.
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 10 March 2009 Resolved
Generators have no Alternating current Measuring Gauges. Install gauges that measure frequency for each Alternating current generator IAW 46 CFR 183.320. Provide proof in 30 Days from 10MAR09.
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 17 April 2009
Resolution: Operator corrected missing Alternating current measuring gauge. Proved operation to MI.
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 February 2008 Resolved
Cleared deficiency #1 issued during COI exam on 15Feb08. Vessel installed temporary loaner liferafts pending return of vessel's permanent liferafts which are delayed due to part on back-order. Issued this CG-835 on 22Feb08 requiring servicing and inspection of installation of permanent liferafts upon return from servicing facility.
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 10 April 2008
Lifesaving › Inflatable Liferafts › Servicing
Issued 15 February 2008 Resolved
Complete servicing and installation of inflatable liferafts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2008
Resolved 22 February 2008
Resolution: Vessel installed temporary loaner liferafts pending return of vessel''s permanent liferafts which are delayed to part on back-order. Issued new CG-835 requiring servicing and inspection of permanent liferafts upon return from servicing facility.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 February 2008 Resolved
Install breaker or blank where missing in breaker box in stateroom A.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2008
Resolved 20 February 2008
Fire Fighting › Grease Extraction Hood › General
Issued 15 February 2008 Resolved
Install corrosion-resistant ducting compliant with NFPA 96 & Sector San [name withheld] #20 from galley fan to exterior of cabin.
Action required: 705 - Other - as specified
Due 16 March 2008
Resolved 20 February 2008
Fire Fighting › Grease Extraction Hood › General
Issued 15 February 2008 Resolved
Clean excessive grease off grease hood filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2008
Resolved 20 February 2008
Stability › Watertight Integrity › General
Issued 7 February 2008 Resolved
Provide captive chain/cable on watertight hatch to lazarette prior to Coastwise/LCW/Oceans route.
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 15 February 2008
Lifesaving › Inflatable Liferafts › Not on Board
Issued 22 February 2007 Resolved
Prove proper installation of inflatable liferafts. Rafts were serviced & on dock ready for re-installation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 23 February 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 February 2007 Resolved
Repair and prove proper operation of port fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2007
Resolved 23 February 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 February 2007 Resolved
Provide currently corrected charts & publications (CG Light List, Coast Pilot [name withheld]) for areas vessel transits.
Condition: Improper/Lack of Maintenance
Due 20 February 2007
Resolved 23 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 20 February 2007 Resolved
Replace missing light cover on aft berthing passage light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 23 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 February 2007 Resolved
Provide first aid kit in compliance w/ 46 CFR 184.710 & 46 CFR 160.041. Vessel had kit O/B, but had expired & missing items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 23 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 February 2007 Resolved
Install cover over hydraulic lines in forward berth to protect occupant from potential hazard.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 1 March 2007
Engineering › Fuel Oil Service System › Hose
Issued 20 February 2007 Resolved
Provide proof that flexible fuel hoses meet SAE J1942 or submit written plan for progressive replacement to SAE J1942.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 1 March 2007
Resolution: Replaced 75% of hoses w/ SAE J1942 hoses; remainder to be replaced in 2008. Special note entered accordingly.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 31 January 2006 Resolved
Provide life rafts for inspections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2006
Resolution: Inspected life rafts which were on board.
Communications › Radio Communications › EPIRB
Issued 31 January 2006 Resolved
Provide documentation for current EPIRB registation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2006
Resolution: Master provide proof of registation.
Electrical › Lighting (service) › Lighting Feeder
Issued 9 January 2006 Resolved
Repair light in lazarett, port side.
Due 1 February 2006
Resolved 10 January 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2006 Resolved
Properly secure/terminate hot dead ended wires in cooks closet, fwd.
Due 1 February 2006
Resolved 10 January 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 January 2006 Resolved
Properly seal two bulkhead penetrations in forepeak, upper starboard side.
Due 1 February 2006
Resolved 31 January 2006
Resolution: Corrected during COI exam.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 January 2006 Resolved
Monitor Carbon Monoxide levels in E/R
Due 1 February 2006
Resolved 13 February 2006
Resolution: Operator purchased CO monitors. Last check on 13FEB06 0ppm CO
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 February 2005 Resolved
Install draft marks
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 11 March 2005
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 10 February 2005 Resolved
Complete FCC SOLAS radio certificate renewal. Complete prior to sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 11 February 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 10 February 2005 Resolved
Label upper deck for maximum passengers (56).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 11 February 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 February 2005 Resolved
Update charts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2005
Resolved 11 February 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 February 2005 Resolved
Rewire engine room relay switch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 11 March 2005
Engineering › Diesel Engine (auxiliary) › Block
Issued 10 February 2005 Resolved
Tighten engine mount bolt located inboard starboard aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 11 March 2005
Resolution: All engine mount bolts were tightened.
Engineering › Generator (propulsion-electric) › Winding
Issued 10 February 2005 Resolved
Clean generator windings.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2005
Resolved 11 March 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 December 2003 Resolved
Dead front all exposed electrical points inside the switchboard door IAW 46CFR183.330(d)
Condition: Improper Installation
Due 15 February 2004
Resolved 22 January 2004
Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 9 December 2003 Resolved
Install smoke detector
Condition: Improper/Lack of Maintenance
Due 15 February 2004
Resolved 10 February 2004
Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 9 December 2003 Resolved
Secure emergency light in aft STBD berthing area
Condition: Improper/Lack of Maintenance
Due 15 February 2004
Resolved 10 February 2004
Engineering › Lubricating Oil Service System › Gauge
Issued 9 December 2003 Resolved
Repair/replace STBD MDE L/O guasge on helm station
Condition: Improper/Lack of Maintenance
Due 15 February 2004
Resolved 10 February 2004
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 9 December 2003 Resolved
provide proof of crew training in STCW requirements prior to next international voyage
Condition: Unknown
Due 15 February 2004
Resolved 10 February 2004
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 9 December 2003 Resolved
Replace alcohol/swab test kit prior to next international voyage
Condition: Improper/Lack of Maintenance
Due 15 February 2004
Resolved 10 February 2004
Engineering › Freshwater System (injector cooling)
Issued 23 January 2003 Resolved
Install main engine cooling exhaust alarms to include visual or audible alarm in the Pilot House. IAW 46 CFR 182.425 (b) (5)
Due 30 January 2003
Resolved 30 January 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 January 2003 Resolved
Install engine exhaust cooling water alarm, either audio or visual in pilot house. LEGACY COMPONENT DESC: Piping (exhaust)
Due 7 February 2003
Resolved 6 January 2004
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 24 January 2002 Resolved
Clean air intake valve in ER and install proper cable connected in a JCT box
Condition: Improper/Lack of Maintenance
Due 24 February 2002
Resolved 31 January 2002
Engineering › Bilge Water Management System › Interface Detector
Issued 24 January 2002 Resolved
Clean ER bilges
Condition: Improper/Lack of Maintenance
Due 24 February 2002
Resolved 30 January 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 January 2002 Resolved
Arrange for witnesses test of fixed fire fighting system
Condition: Unknown
Due 24 February 2002
Resolved 30 January 2002
Engineering › Bilge Water Management System › Hose
Issued 24 January 2002 Resolved
Provide proper hoses for hand bilge pump and demonstrate pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 30 January 2002
Communications › Alarms/Indicators › General Alarm
Issued 24 January 2002 Resolved
Repair PA system
Condition: Improper/Lack of Maintenance
Due 24 February 2002
Resolved 30 January 2002
Lifesaving
Issued 2 February 1999 Resolved
Provide serving report for fixed CO2 system.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Documentation
Issued 2 February 1999 Resolved
Identify the responsible person for companies ISM program. _x001C_ Enter Correction recharge date on engine room fixed CO2 system. Complete distribution of Manuals, Drug testing instructions, ensure all crew memberssign, acknowledgment of companies policies and proceedures.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 2 February 1999 Resolved
Vessel missing evidence of compliance with specimen collection requirementsof 46 CFR 4.06-20.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Documentation
Issued 2 February 1999 Resolved
Missing current Drug testing program and records.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Documentation
Issued 2 February 1999 Resolved
Missing drug and alcohol awareness manual.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 9 April 1998 Resolved
PROVIDE AND POST STATION BILL.
Condition: Unknown
Due 24 April 1998
Resolved 13 April 1998
Fire Fighting
Issued 9 April 1998 Resolved
TEST FIXED FIRE FIGHTING SYSTEM AS PER 46CFR181.410.
Condition: Unknown
Due 24 April 1998
Resolved 13 April 1998
Electrical
Issued 9 April 1998 Resolved
RENEW FIVE STUFFING TUBES ON 12VDC PANNEL IN ENGINE ROOM.
Condition: Unknown
Due 24 April 1998
Resolved 13 April 1998
Lifesaving
Issued 8 April 1997 Resolved
Demonstrate proper underway drills including man overboard, abandon ship and fire situations with crew.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Fire Fighting
Issued 21 January 1997 Resolved
Install a approved fixed CO2 system in the engine room._x001C_
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Lifesaving
Issued 21 January 1997 Resolved
Comply with new IFR requirements from memo dated 16 Aug96._x001C_
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Engineering
Issued 15 April 1996 Resolved
prove lifting pressure of relief valve on air compressor in engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Navigation
Issued 15 April 1996 Resolved
prove proper operation of mast head light and all around anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 2 February 1995 Resolved
PROVIDE MEANS FOR LOCKING MSD OVERBOARD DISCHARGE VALVE ON PORT SIDE.
Condition: Unknown
Due 9 February 1995
Resolved 3 February 1995
Fire Fighting
Issued 2 February 1995 Resolved
RECHARGE ENGINE ROOM PORTABLE FIRE EXTINGUISHER PRIOR TO CARRYING PAX.
Condition: Unknown
Due 9 February 1995
Resolved 3 February 1995
Construction/Loadline
Issued 2 February 1995 Resolved
REPLACE WORN GASKETS ON STARBOARD AND FOREPEAK HATCHCOVERS.
Condition: Unknown
Due 9 February 1995
Resolved 3 February 1995
Documentation
Issued 4 November 1994 Resolved
PROVIDE THE CORRECT CALL SIGN ON VESSEL'S FCC CERTIFICATES.
Condition: Unknown
Due 4 November 1994
Resolved 4 November 1994
Electrical
Issued 18 May 1994 Resolved
PROVIDE AND INSTALL LOCK-OUT DEVICE TO PREVENT PARALLELING OF SHORE POWER AND GENERATORS.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Navigation
Issued 18 May 1994 Resolved
SUBMIT PROPOSAL FOR PREVENTION OF CHAFING OF BAIT TANK PIPING WITH STEERINGRAM. (AS PROPOSAL WAS NOT SUBMITTED PRIOR TO EFFECTING MODIFICATIONS, PRESENT REQUIREMENT IS TO PROVIDE MARINE INSPECTOR WITH ACCESS TO STEERING GEAR FOR EXAMINATION WHILE VESSEL IS UNDERWAY.)
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Lifesaving
Issued 18 May 1994 Resolved
PROVIDE 2 NEW SEA PAINTERS FOR L/F PRIOR TO CARRYING PAX.
Condition: Unknown
Due 28 May 1994
Resolved 23 May 1994
Electrical
Issued 18 May 1994 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHTING IN THE AFT PASSENGER COMPARTMENT PRIOR TO CARRYING PAX.
Condition: Unknown
Due 28 May 1994
Resolved 23 May 1994
Fire Fighting
Issued 18 May 1994 Resolved
PROVE PROPER OPERATION OF SMOKE DETECTORS.
Condition: Unknown
Due 28 May 1994
Resolved 23 May 1994
Accommodation/Occupational Safety
Issued 18 May 1994 Resolved
PROVIDE POSITIVE LOCKING DEVICE FOR O/B DISCHARGE VALVE OF MSD.
Condition: Unknown
Due 28 May 1994
Resolved 23 May 1994
Electrical
Issued 18 May 1994 Resolved
PROVIDE AND INSTALL EXPLOSION PROOF SLEEVES FOR FLUORESCENT LIGHTING OVER STOVES.
Condition: Unknown
Due 28 May 1994
Resolved 23 May 1994
Electrical
Issued 18 May 1994 Resolved
PROPERLY SECURE BATTERIES.
Condition: Unknown
Due 28 May 1994
Resolved 23 May 1994
Deck/Cargo
Issued 14 December 1993 Resolved
HYDRO TEST HYDRAULIC PIPING TO ANCHOR WINDLESS.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Construction/Loadline
Issued 14 December 1993 Resolved
PROVIDE PROPER CAPTURE CHAIN FOR THE REEFER SPACE HATCH.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Construction/Loadline
Issued 14 December 1993 Resolved
REPAINT DRAFT MARKS BEFORE DEPARTING DRYDOCK.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Engineering
Issued 19 May 1993 Resolved
PROVE PROPER OPERATION OF PORT SIDE THROTTLE CONTROLS.
Condition: Unknown
Due 19 May 1993
Resolved 19 May 1993
Navigation
Issued 19 May 1993 Resolved
PROVIDE UPDATED/CORRECTED PUBLICATIONS IN ACCORDANCE WITH OFFICER IN CHARGEOF MARINE INSPECTIONS, LOS ANGELES-LONG BEACH, MEMO DATED 01 JUNE 1992.
Condition: Unknown
Due 19 May 1993
Resolved 19 May 1993
Navigation
Issued 20 May 1992 Resolved
THE VESSEL MAY NOT OPERATE MORE THAN 60 MILES FROM A BASELINE EXTENDING FROM POINT CONCEPTION, CA, TO CAPE SAN LUCAS, BAJA CALIFORNIA, MEXICO UNTILA 406 MHZ EPIRB IS PROVIDED OR AN EXEMPTION IS OBTAINED FROM THE FCC.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Electrical
Issued 22 May 1990 Resolved
PROVIDE METALLIC SUPPORTS FOR WIRING IN THE E/R AT INTERVALS OF NOT LESS THAN 2 FEET.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Electrical
Issued 22 May 1990 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTS TO FWD BERTHING AREA.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Electrical
Issued 22 May 1990 Resolved
PROVIDE COVERS FOR EXPOSED LIGHTS IN PASSENGER BERTHING.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Construction/Loadline
Issued 18 November 1989 Resolved
EFFECT PERMANENT REPAIRS TO THE COLLISION DAMAGE IN WAY OF THE BOW; THE PROPOSED AREAS TO BE REMOVED SHOULD BE PROVIDED TO THE COGNIZANT OCMI FOR APPROVAL.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Deck/Cargo
Issued 18 November 1989 Resolved
PROVE PROPER OPERATION OF THE ANCHOR WINDLASS.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Navigation
Issued 18 November 1989 Resolved
PROVE PROPER OPERATION AND INSTALLATION OF THE PORT NAVIGATION RUNNING LIGHT.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Navigation
Issued 26 May 1989 Resolved
PRIOR TO OPERATING WITH PASSENGERS PROVIDE VESSEL FOR EXAMINATION BY MARINEINSPECTOR FROM MSO LOS ANGELES / LONGBEACH CA.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Accommodation/Occupational Safety
Issued 26 May 1989 Resolved
NON-SKID STEPS ON LADDER TO UPPER DECK.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Engineering
Issued 26 May 1989 Resolved
INSTALL PERMANENT GUARDS ON PROPULSION ENGINE COUPLINGS.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Electrical
Issued 26 May 1989 Resolved
REPLACE 20 AMP BREAKERS IN DISTRIBUTION PANELS FOR LIGHTING SYSTEM WITH 15 AMP BREAKERS.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Electrical
Issued 26 May 1989 Resolved
REPLACE 400 AMP GENERATOR BREAKERS WITH 300 AMP BREAKERS.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Navigation
Issued 26 May 1989 Resolved
PROVIDE A COMPASS DEVIATION TABLE.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989

Casualty record · 3

28 November 2006Routine · role: Transiting Vicinity of Primary Subject · 1 injured · activity 2831539
8 July 2012Routine · role: Involved in a Marine Casualty · activity 4372125
24 June 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4900742
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.