Records from 2006 to 2026. Most recent: inspection, 27 January 2026.
Inspection history · 40
27 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8302528
30 October 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8260857
8 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108124
31 January 2025
Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8072947
4 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7891967
20 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7867561
24 August 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789659
17 April 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670502
20 March 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7653479
31 January 2023
Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629475
7 November 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7590492
28 June 2022
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7489915
29 March 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504007
7 March 2022
MTSA/ISPS Verification · COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7403382
28 January 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7387163
24 September 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319876
19 March 2021
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7159356
16 February 2021
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7141214
25 September 2020
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7065322
24 September 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7112505
24 September 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126943
24 September 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126948
24 September 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7126951
31 July 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7021157
24 March 2020
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930946
13 February 2020
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6908436
19 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6837713
1 April 2019
Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6632180
27 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6633772
24 November 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596599
10 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6536891
14 March 2018
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6372081
7 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6367580
10 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6286167
6 April 2017
Inclining Experiment · Administrative Inspection · Deadweight Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128975
25 January 2017
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6076982
20 January 2017
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6074315
2 December 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6051728
20 January 2016
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800749
15 January 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5798148
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2025
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Vessel did not have approved marine type strainer installed.
Cite: 46 CFR 182.455(b)(6).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2025
Resolution: Received satisfactory evidence of marine grade filters installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was five short of the required amount of adult life jackets at the time of the inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2024
Resolved
Electrical equipment o/b vessel must be installed and maintained to protect passengers, crew and other persons and the vessel from electrical hazards. Following electrical safety infractions during exam:
-Must mount break switches for pump systems in engine switchboard.
-Must mount junction box located in port aft accom space closet.
-Must provide cover for electrical outlet in port aft accom space closet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2024
Resolved 25 April 2024
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024
Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the fire extinguisher securely in it's stowage location. Must provide and mount suitable bracket for fire extinguisher in engine space capable of quick release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 25 April 2024
Resolution: Corrected
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 April 2024
Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly and logged. Logs for monthly EPIRB tests not available for inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 February 2024
Resolved
Grind out suspected crack weld where keel meets hull plating, aft / stbd. Submit repair proposal once area is grinded out.
Action required: 705 - Other - as specified
Resolved 27 February 2024
Resolution: Area in question was ground out, drill stopped, and re-welded.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 March 2023
Resolved
Both life rafts that were recently serviced is not properly attached from its pendant to its hydrostatic release unit. Make proper arrangements and secure.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 20 March 2023
Resolution: Corrected & verified by USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023
Resolved
Insulation around both main and generator turbochargers
found to be missing. Provide approved insulation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023
Resolved
Unprotected electrical wire found above port generator;
Remove or terminate into junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023
Resolved
AFT bathroom overhead electrical receptacle outlet loose and properly secured. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023
Resolved
Main deck at bow centerline light fixture next to life ring missing diffuser. Repair
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023
Resolved
Fore peak light fixture missing bulb, diffuser, and not properly mounted. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023
Resolved
01 Deck aft near life ring buoy center light fixture missing bulb & diffuser. Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2023
Resolved
01 Deck life ring buoys name stencil peeling; Repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 4 April 2024
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 March 2023
Resolved
Provide plan proposal for installation of stairs in Aft Passenger cabin to aid in means of Escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 February 2024
Resolution: Vessel met requirements of IFR
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 March 2022
Resolved
Two vessel masters were missing STCW endorsements (one medical and one MMC). Present evidence of sufficiently licensed crewmembers. This is to be rectified prior to sailing foreign. Cite: I/9.3 and I/2.11.
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: Vessel is no longer on a SOLAS route, so the deficiency no longer applies.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 March 2022
Resolved
Provide FCC Marine Radio Operator Permits for all licensed crewmembers. Cite: 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2022
Resolved 28 June 2022
Resolution: Received an email with scans of the crews' newly acquired FCC Marine Radio Operator Permits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2022
Resolved
Properly secure fwd berthing bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 30 March 2022
Resolution: Received email with picture of corrected bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2020
Resolved
Correct the following electrical items:
Identify load for breaker #7 on bridge panel.
Replace 16 AWG wire for produce box
Splice found at produce box. Install into a junction box
Correct circuit breaker or cabling IAW produce box
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: Electrical issues addressed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2020
Resolved
Port side battery box must be secured to ship to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: verified battery box secured properly
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 24 March 2020
Resolved
Replace 02 missing light covers in galley and engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: covers replaced
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 24 March 2020
Resolved
Secure port side auxillary pump to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2020
Resolved 23 April 2020
Resolution: verified pump secured
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 24 March 2020
Resolved
Conduct drills in presence of Marine Inspectors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2020
Resolution: Drill log verified in lieu of performing drills
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 October 2019
Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation duct from galley. Diesel soaked rags/sorbents in open plastic bucket found in E/R (corrected on the spot).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Fire hazards removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations below deck. Vessel did not have lighting at the aft emergency exit hatch in stateroom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: E. light added and tested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 October 2019
Resolved
Each hatch used as a means of escape must be obvious and rapid to open in an emergency. Mark emergency escape in aft stateroom with easy to understand instructions for opening water tight hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Signage added.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2019
Resolved
Complete & simple instructions for the operation of the E/R CO2 system must be located at each pull box. Properly label instructions for system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Instructions added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Correct the following found: 1) Motor control electrical connection on purifier. 2) Clean excessive dust/debris from inside breaker panels. 3) Attach face-plates/covers on outlets/j-boxes in aft passenger accommodation overhead and crew bunk area. 4) Mount hanging J-box in crew accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 2 March 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 31 July 2020
Resolution: AC 1-line verified and stamped by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 April 2019
Resolved
Provide machinary guards for exposed moving machinary on generators.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 4 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 April 2019
Resolved
Re-label breaker box in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 4 April 2019
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 1 April 2019
Resolved
Replace and/or clean flame screens on fuel vents.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 4 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 April 2019
Resolved
Provide up-to-date navigation charts.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 4 April 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 April 2019
Resolved
All vessel masters must review SMS plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 4 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2019
Resolved
Repair port and starboard fuel shut offs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS.
Lifesaving › Lifebuoys › Serviceable
Issued 20 March 2018
Resolved
Install retro-reflective material and vessel name on forward lifering buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: Retro-reflective material installed
Communications › Radio Communications › EPIRB
Issued 20 March 2018
Resolved
Provide NOAA registration and decal for EPIRB
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: NOAA registration is onboard the vessel and decal properly place on the EPIRB
Engineering › Fuel Oil Service System › Filter
Issued 20 March 2018
Resolved
Remove plastic fuel filter on the fuel transfer piper or install correct filter
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: The plastic filter was removed.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 20 March 2018
Resolved
Remove electrical hazard on electric box in engine room stbd side
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 26 March 2018
Resolution: The hazard was eliminated.
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 10 October 2017
Resolved
Prove proper operation of port engine gear box.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 7 February 2017
Resolved
Prove proper operation of all radio equipment. Send copy of FCC Safety Certificate to attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2017
Resolved 8 February 2017
Fire Fighting › Fire Pumps › Pressure
Issued 7 February 2017
Resolved
Provide working pressure gauge for fire pump.
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 7 March 2017
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 2 December 2016
Resolved
Provide plans for engineering, electrical and manufacturers installation for main engine propulsion control.
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 23 January 2017
Resolution: Vessel rep submitted drawings. All sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 January 2016
Resolved
Properly install distribution panel for electrical system in fwd engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 17 May 2016
Resolution: The panel was replaced.