MAURY USCG vessel records
← All vessels

N.D RICHMOND

N.D RICHMOND is a 1989 towing vessel. The Coast Guard has recorded 32 inspections since 1994, most recently in February 2026, along with 25 deficiencies and 6 casualty investigations between 2005 and 2023.

Records from 1994 to 2026. Most recent: inspection, 10 February 2026.

Built
1989
Last inspected
10 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 10 February 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 19 calendar years (1994–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ7345
328852
Flag
UNITED STATES
Maury page id
psix-328852

Documentation record

Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 61 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS, INC. · UTICA, IN, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portROCKPORT, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Simplified, Gross Ton
49 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

32 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; 7 vessels inspected with it, by name and date; 6 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 32

10 February 2026 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8302845
3 June 2025 Drydock Exam · Internal Structural Exam · Vessel Attendance · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8146497
19 September 2024 Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8005488
22 August 2024 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7962378
20 July 2023 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7747515
8 June 2023 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7659199
13 March 2023 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7651859
26 May 2022 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7442539
16 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7232847
7 January 2021 Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7121062
7 January 2021 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7233013
18 June 2020 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7031902
7 January 2020 Deficiency Check · Administrative Inspection · Damage Survey · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6884149
2 April 2019 Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6655153
29 March 2019 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6669239
7 February 2018 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6351699
27 October 2016 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6032456
26 August 2014 Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4966161
14 June 2011 Administration · Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4044724
27 October 2010 Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3879805
17 February 2005 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2301279
12 February 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2005487
3 February 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1999613
31 July 2002 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1654834
17 January 2002 Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1479431
2 September 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 5307
4 February 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 651594
19 January 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 424755
8 October 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 769123
7 October 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 193122
6 May 1994 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 688000
22 April 1994 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 125023

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 February 2026 Resolved
All piping, controls, valves, and alarms must be inspected to determine that the system is operating properly. Fire main discharge pipe leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2026
Resolution: Fire main discharge pipe replaced
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 February 2026 Resolved
Electrical systems must maintained to provide for safe operation of the towing vessel and safety of persons onboard. Miscellaneous dead end wires exposed on both MDEs inboard side and in accommodation space outside of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2026
Resolution: All dead end wires have been fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2026 Resolved
Machinery must be maintained to provide for safe operation of the towing vessel and safety of persons onboard. Missing throttle linkage bolt to actuator. Repair prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2026
Resolution: replaced throttle linkage bolt to actuator.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 February 2026 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. STBD ventilation fan oil soaked. Clean and ensure no more accumulation of oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2026
Resolution: Cleaned ventilation fans
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 10 February 2026 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including potable water supply. Pipe screen damaged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2026
Resolution: replaced pipe screen
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 June 2021 Resolved
Vessel was constructed with the MSD located in the FWD Peak compartment with the discharge pipe below the water line without a closure device.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 10 August 2021
Resolution: Check valve installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 January 2021 Resolved
Stbd gen-set experienced small electrical fire, causing gen-set to be taken offline. Vsl required to have generator repaired within 14 days. Authorized to operate with port generator.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 22 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 August 2020 Resolved
Vessel's rudder's hydraulic lines chaffing on deck plates. Vessel to alter lines to prevent chaffing and undue wear to steering systems.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 August 2020 Resolved
Vessel's MDE stacks are within arms length of ladders on Texas deck. Install adequate guards on stacks to prevent risk of burns.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 August 2020 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Found multiple items in first aid cabinet beyond their expiration date. Replace items that are beyond their expiration date
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020 Resolved
Nonconductive mats or grating must be provided on the deck in front of each switchboard. The fuse panel on the bulkhead of the upper engine room catwalk did not have a nonconductive mat on the deck. Add mat to deck in front of panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2020 Resolved
On 18 June 2020 the ITV N. D. RICHMOND experienced a failure of the port throttle control while conducting fleeting operations IVO Ohio River mile 745 and the vessel proceeded to the Indiana Michigan Power Co. dock for the crew to troubleshoot. Vessel required to conduct repairs and contact Coast Guard marine inspector at below listed email when repairs are completed and before placing vessel back into service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2020
Resolved 19 June 2020
Resolution: Item cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 January 2020 Resolved
All lifejacket containers must be marked in block capital letters and numbers with the minimum quantity and identity stowed inside the container. The locker holding the lifejackets was labelled without the number of lifejackets inside. Re-label with correct number.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019 Resolved
Vessel experienced damage to port reduction gear while conducting fleeting operations IVO Ohio River mile 745. Vessel required to conduct repairs and contact Sector Ohio Valley duty marine inspector at [phone withheld] when repairs are completed and before placing vessel back into service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
Accommodation/Occupational Safety
Issued 19 January 1999 Resolved
THE MSD ON THE VESSEL DID NOT HAVE ANY CHEMICAL TABLETS IN THE RESERVOIR. COMPANY OFFICIALS PURCHASED TABLETS FROM LOCAL STORE AND FILLED RESERVOIR PRIOR TO USING MSD.
Condition: Unknown
Due 19 January 1999
Resolved 21 January 1999
Unknown
Issued 19 January 1999 Resolved
LOG OF VESSEL TESTS AND INSPECTIONS WAS NOT BEING KEPT.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Documentation
Issued 19 January 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999 Resolved
VESSEL DID NOT HAVE A COPY OF THE CG LIGHT LIST ON BOARD.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999 Resolved
THERE WERE NO CHARTS FOR THE AREA TRANSITTING. CURRENT EDITION OF CHARTS PLACED ON BOARD VESSEL VIA FAX.
Condition: Unknown
Due 19 January 1999
Resolved 21 January 1999
Navigation
Issued 19 January 1999 Resolved
VESSEL DID NOT HAVE A COPY OF LOCAL NOTICE TO MARINERS ON BOARD.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Unknown
Issued 19 January 1999 Resolved
STARBOARD SEARCHLIGHT WAS NOT WORKING. DECK HAND REPLACED THE BULB, LIGHT STILL DID NOT WORK.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999 Resolved
STERN LIGHT WAS INOPERATIVE. THERE WAS NO BULB IN LIGHT. DECK HAND INSTALLED BULB, LIGHT WAS STILL INOPERATIVE. WIRES AND PLUG LOOKED GOOD.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999 Resolved
PORT RUNNING LIGHT WAS INOPERATIVE, THE DECKHAND REPLACED BULB AND CORRECTED DISCREPANCY.
Condition: Unknown
Due 19 January 1999
Resolved 21 January 1999
Navigation
Issued 19 January 1999 Resolved
MASTHEAD LIGHT WAS INOPERATIVE. REPLACED BULB AND STILL DID NOT WORK.
Condition: Unknown
Due 19 February 1999
Resolved 16 January 2002
Resolution: Masthead light was operable during annual CTVEP boarding.
Navigation
Issued 19 January 1999 Resolved
ANCHOR LIGHT WAS INOPERATIVE. DECK HAND REPLACED BULB AND CORRECTED DISCREPANCY.
Condition: Unknown
Due 19 January 1999
Resolved 21 January 1999

Casualty record · 6

17 February 2005Routine · role: Involved in a Marine Casualty · activity 2301279
7 February 2018Routine · role: Sighted in Area · activity 6351699
29 March 2019Routine · role: Involved in a Marine Casualty · activity 6669239
18 June 2020Routine · role: Involved in a Marine Casualty · activity 7031902
7 January 2021Routine · role: Involved in a Marine Casualty · activity 7233013
13 March 2023Routine · role: Involved in a Marine Casualty · activity 7651859
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.