CALIFORNIA HORNBLOWER

CALIFORNIA HORNBLOWER is a 1989 passenger vessel (inspected). The Coast Guard has recorded 136 inspections since 1989, most recently in April 2026, along with 181 deficiencies, 9 operational controls and 11 casualty investigations between 2006 and 2026.

Records from 1989 to 2026. Most recent: inspection, 28 April 2026.

Built
1989
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8632
329626
Flag
UNITED STATES
366961920
Maury page id
psix-329626

Inspections, by type

…with no type recorded35
Years with a record 37 calendar years (1989–2026)
The 136 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)173.5 ft × 38.0 ft × 9.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMOSS POINT MARINE INC · ESCATAWPA, MS, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
550 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8632MMSI 366961920 · active · compulsorily equipped · granted 13 June 2024, expires 3 July 2034
WAC6776MMSI not assigned · expired · compulsorily equipped · granted 3 May 1994, cancelled 22 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ROYAL STAR Passenger (Inspected) · MISLE 46517 · 15 July 2006 · activity 2826262ROYAL STAR Passenger (Inspected) · MISLE 46517 · 3 March 2006 · activity 2597759THORSKY Freight Ship · MISLE 494238 · 3 March 2006 · activity 2597759

Inspection history · 136

28 April 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8357209
7 March 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8323234
6 March 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8321284
6 January 2026 Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8291423
1 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099687
18 June 2024 In-Service Inspection · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7937615
23 January 2024 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7853251
28 October 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821461
27 October 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7815800
15 August 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7768166
15 June 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7716122
10 May 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685680
21 January 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7625523
29 November 2022 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601599
23 June 2022 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7484893
21 June 2022 Administrative Inspection · Inclining Experiment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7483894
18 January 2022 Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7381618
18 January 2022 Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7513492
29 July 2021 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271922
19 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7201454
25 April 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7308686
9 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6971115
8 January 2020 Deficiency Check · In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6885010
26 March 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6649369
5 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6555450
25 June 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6455859
17 June 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6468065
19 March 2018 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6375154
23 February 2018 Drydock Exam · Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6362161
13 June 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6175120
30 April 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6139106
8 March 2017 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6104142
7 March 2016 Internal Structural Exam · Annual Inspection · Administrative Inspection · Examination of Repairs · Drydock Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828478
28 February 2016 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828870
27 February 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5825059
24 November 2015 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5769907
20 March 2014 Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4819623
15 May 2012 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4329172
28 February 2012 Drydock Exam · Administrative Inspection · Construction Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4253171
6 February 2012 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4239354
27 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4096748
27 July 2011 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4102190
27 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4109430
22 March 2010 Deficiency Check · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3700427
7 March 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3692136
6 March 2010 Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3691254
23 March 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3434990
20 February 2009 Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3444271
29 April 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3186116
26 March 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3166077
12 June 2007 Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966036
8 June 2007 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2955622
2 May 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2917259
26 March 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2875085
21 July 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2720342
15 July 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2826262
21 June 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2686896
31 May 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2666638
22 May 2006 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2655982
21 April 2006 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2630318
21 March 2006 Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2594923
3 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2597759
26 February 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2601638
20 May 2005 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2365964
25 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2342747
4 April 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2295138
4 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2326478
10 March 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2307313
30 December 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2284043
18 August 2004 MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2117585
18 August 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2169896
22 March 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2029044
16 March 2004 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2024843
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970853
17 November 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1949055
16 October 2003 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1929825
19 May 2003 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1792027
7 April 2003 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1746677
1 April 2002 Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1599589
10 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1073731
12 July 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1067855
27 March 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1389350
18 April 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1432310
24 November 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1399233
7 April 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1375706
14 January 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809574
8 December 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 808166
1 December 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 806518
2 November 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390862
27 May 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 791536
27 February 1998 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 783720
23 January 1998 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1115120
13 May 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103509
24 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 87890
19 December 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1094104
12 November 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1438510
18 September 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 829862
18 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834556
7 May 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1082668
8 April 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083607
10 April 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154391
14 November 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 868179
31 May 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1014402
26 April 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 447793
11 April 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167325
10 January 1994 Deficiency Check · Drydock Extension
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850891
15 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139276
19 August 1993 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155631
23 April 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1136601
23 April 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1150498
13 April 1993 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132424
28 April 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391764
14 April 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257845
28 February 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 952872
14 February 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962138
9 October 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937897
19 August 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942618
20 June 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937483
12 June 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1326941
1 May 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 911848
18 April 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 916372
26 October 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229502
5 September 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212647
3 July 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238914
18 May 1990 Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 903043
18 May 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952433
3 May 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235657
26 September 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210173
22 September 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 895942
17 August 1989 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 897624
15 August 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1044291
15 August 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348257
28 July 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 899238
29 June 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 902127
9 June 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 890668
6 May 1989 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350023

Deficiency record · 181

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Junction box in CO2 space was missing the cover. 46 CFR 120.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2026
Resolution: Operator emailed photo of cover installed on junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Burn cream in first aid kit was expired. 46 CFR 121.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2026
Resolution: Operator has burn spray on board that meets requirements in ISO 18813:2006
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 April 2026 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Port aft door on main deck does not fully close and seal; restore weathertight integrity to satisfaction of the MI.46 CFR 116.1160(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 28 April 2026
Resolution: Verified proper operation of door
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 March 2026 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Sector SF Command Center was notified of the vessels collision of port stern side with Pier 1 damaging windows and structural frames. Rectify prior to the carriage of passengers. 46 CFR 116.1020
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2026
Resolution: Completed repairs to windows and MI attended for inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 1 April 2025 Resolved
Doors on a cooking appliance must be provided with hinges and locking devices to prevent accidental opening in heavy seas. Three ovens in the galley are not fitted with locking devices. 46 CFR 121.220(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 10 April 2025
Resolution: Accepted photos of installed oven door latches.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2024 Resolved
Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter) All doors... shall be of type which are capable of release from the control station and from a position at the door. The release mechanism shall be designed that the door will automatically close in the event of disruption to the control system. MI observed the vessel's double doors between galley and pantry did not latch all the way. 46 CFR 177.10-5 (Old T) 46 CFR 72.05-25(b)(9)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 1 October 2024
Resolution: Witnessed proper closure of self-closing door.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 June 2024 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. Quick-closing watertight door at frame 33 is not installed with a position indicator at the operating station 46 CFR 177.13 Old T 46 CFR 170.270 (e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 28 May 2026
Resolution: Vessel given special consideration.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 June 2024 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Dead end wires were discovered in void 2, within halon storage void, on Generator 1 ECM connection, and within the pantry store port side of ladder within condensate drain containment. Additionally, light cover over Generator 2 is broken and dangling. 46 CFR 176.25-50 Old T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 1 October 2024
Resolution: Verified removal of dead end wires
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2024 Resolved
All safety and relief valves for use on pressure vessels or piping systems shall...shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel. The vessel was not able to test the operation of the starboard pressure relief valve in the engine room. Vessel operator to provide testing procedure to ensure that the pressure relief valve is operational at the intended pressure. 46 CFR 119.330 46 CFR 54.15-10 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 10 July 2024
Resolution: Witnessed operation of pressure relief valve. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 18 June 2024 Resolved
The inspection shall be such as to insure that the vessel…piping… is in satisfactory condition and fit for the service for which it is intended. MI observed improper repair to piping in small void of pantry store ladder, forward of tonnage opening on port side. 46 CFR 176.05-10(a) (Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 1 October 2024
Resolution: Operator removed sink, and capped both ends of pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 June 2024 Resolved
The inspection shall be such as to insure that the vessel…electrical installations…is in satisfactory condition and fit for the service for which it is intended. MI observed inoperable lights within Void 2. 46 CFR 176.05-10(a) (Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 10 July 2024
Resolution: Lights replaced in void two, tested satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2024 Resolved
Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. Marine inspector observed nonconductive matting was missing from switchboard on port side of galley, and at rear of main switchboard in engine room. 46 CFR 183.10-15(b) (Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 24 July 2024
Resolution: Verified placement of matting via emailed photograph
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 June 2024 Resolved
Adequate emergency lighting..shall be fitted along the line of escape. MI observed inoperable emergency light on bulkhead of pantry store ladder well. 46 CFR 184.30-5(a)(Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 10 July 2024
Resolution: Tested light satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 January 2024 Resolved
A self-propelled vessel of 65 feet or more in length, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. Vessel's AIS is not functioning properly due to inability to broadcast. Provide root cause and repair AIS to the satisfaction of the Marine Inspector. 33 CFR 164.46(b)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2024
Resolution: Vessel installed a new antenna for AIS. Cleared deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 October 2023 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: vital systems, interior lighting, communication systems, navigation lights. Vessel reported failure of one of two generators onboard. Conduct repairs on inoperable generator with satisfactory operational tests.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2023
Resolution: Fuel pump replaced and satisfactory operational test was conducted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2023 Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire. Fire damper in ventilation duct serving galley on STBD side bow inoperable. Repair to satisfaction of marine inspector prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2023
Resolution: Vessel repaired and showed operation to the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 August 2023 Resolved
Main vertical zones are those sections, the mean length of which does not, in general, exceed 131 feet on any one deck, into which the hull, superstructure, and deckhouses are required to be divided by fire-resisting bulkheads. Class A boundary penetration above Port Side Galley fire screen door is missing complete sealant. Seal to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 August 2023
Resolution: Class A boundary penetration above Port Side Galley fire screen door has been sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Insufficient amount and locations of life jacket donning instructions throughout vessel. Provide additional instructions in vicinity of each life jacket stowage area to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 August 2023
Resolution: Vessel posted life jacket donning instructions throughout the ship in places easily accessible to crew and passangers, primarily in the lids of life jacket containers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2023 Resolved
A vessel at anchor shall exhibit where it can best be seen: (i) In the fore part, and all-round white light or one ball. Anchor light inop. Repair to the satisfaction of the attending marine inspector. 33 CFR 83.39(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 September 2023
Resolution: Completed repair of the anchor light to the satisfaction of the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 August 2023 Resolved
Doors in “A” Class bulkheads shall meet the following requirements: the bottoms of doors may be undercut not to exceed 1/2 inch above the door sill or top of approved deck covering. Rugs, and carpets, shall not pass through doorways, but linoleum and similar coverings may do so. Multiple doors throughout vessel (main deck aft center door, main deck starboard side aft, starboard galley door, 2nd deck service areas center door) exceed .5” undercut. Provide maximum undercut distance to satisfaction of attending marine inspector. Due at next credited dry dock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 February 2024
Resolution: Temporary Repair affixed - to be fixed permanately at next dry-dock.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 August 2023 Resolved
Doors in bulkheads required to be Class A–60, A–30, or A–15 shall be of hollow steel or equivalent metal construction solidly filled with approved structural insulation capable of meeting the requirements for a Class A–15 bulkhead. Port Galley door is missing a handle. 3rd deck fire screen door handle is lose and not designed for that door. Install appropriate handles to both doors to the satisfaction of the marine inspector. Due at next credited dry dock
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 23 January 2024
Resolution: Appropriate handles were installed as required and verified during drydock inspection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 August 2023 Resolved
Doors in bulkheads required to be Class A–0 shall be of solid or hollow steel or equivalent metal construction capable of meeting the requirements of a Class A–0 bulkhead. Galley stores fire screen door has bracket hole penetrations. Restore structural fire protection of the door to the satisfaction of the marine inspector. Due at next credited dry dock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 February 2024
Resolution: Temporary Repair affixed - to be fixed permanately at next dry-dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 August 2023 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] temporary repairs made to galley stores drainage pipes. Repair pipes to the satisfaction of the attending marine inspector. Temp repairs made. Vessel to conduct permanant repairs at next credited dry dock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 19 February 2024
Resolution: Extended-To be fixed permanately at next dry-dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 August 2023 Resolved
Penetrations and openings in watertight bulkheads must have means of making them watertight. Reefer flat bulkhead has 03 through-hull penetrations. Fill through-hull penetrations to ensure watertight bulkhead to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 August 2023
Resolution: Vessel filled 03 bulkhead penetrations in the reefer flat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 August 2023 Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear. Rudder angle indicator at emergency steering station in engine room inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 September 2023
Resolution: Vessel completed repairs of rudder angle indicator to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2023 Resolved
All electrical equipment including motors, generators , controllers, distribution panels, etc., shall be drip-proof protected. Drip-proof protected means that equipment and machinery is so constructed or protected that its successful operation is not interfered with when subjected to falling moisture or dirt, and rotating or uninsulated parts cannot be inadvertently touched or approached nearer than a safe distance by any person. Engine room breaker panel missing a blank. Galley feeder panel has large blank space. Ensure distribution panels are fully drip-proof and do not allow inadvertent touching of electrical circuits to the satisfaction of the attending marine inspector. 46 CFR 183.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 August 2023
Resolution: Vessel installed blanking plate to galley feeder panel blank space.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2023 Resolved
If 1 1/2 inch diameter fire hose is used, each length of hose must: have a nozzle that has a 1/2 inch solid stream orifice or a combination nozzle approved by the Commandant. The nozzle must be bronze or another material that has strength and corrosion resistance properties equal to those of bronze. Engine room fire station nozzle will not close. Repair or replace nozzle to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 29 August 2023
Resolution: Vessel replaced nozzle that is fully functional.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2023 Resolved
Electrical equipment exposed to the weather deck must be watertight. Starboard side radio antenna on top of the pilot house has a broken through-hull to the bridge. Temporary repair authorized to the satisfaction of the attending marine inspector with a full repair to be completed at next dry-dock. 46 CFR 183.210(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2023
Resolved 19 February 2024
Resolution: Vessel completed temporary repair of the wire through-hull to be fixed permanately at next dry-dock.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 August 2023 Resolved
The release mechanism shall be so designed that the door will automatically close in the event of disruption to the control system. Vessels galley doors are installed with sensors to automatically open and close doors. Vessels door sensors continue to operate after the disruption of the control system. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2023
Resolved 29 September 2023
Resolution: Vessel door sensors now work as intended and were tested to ensure fire boundries met to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Transmission failure must be repaired to the satisfaction of the attending MI prior to carriage of passengers. Vessel is cleared to host event on 28 May, while tied to the dock.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2023
Resolution: Verified transmission repair with sea trial.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including operation of the fire main system and checking of the pressure at the most remote and highest outlets. Firemain is leaking/fractured in tank void space. Identified while testing fire hose.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 July 2022
Resolution: All leaks in fire main repaired by replacment of in kind pipe. Pressured tested to MAWP of fire pump, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 June 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including inspection and testing of fire confining appliances (such as fire screen doors and fire dampers). Fire dampers failed to actuate to engine room.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 July 2022
Resolution: Fire damper handle is now operational. Inspected by MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including testing of each fire hose to a test pressure equivalent to its maximum service pressure. Fire hose on 2nd deck sustained punctures and required replacement. Corrected on spot
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 June 2022
Resolution: Replaced damaged hose
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2022 Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use. During vibration testing, the extinguisher must be tested in the marine bracket. Portable extinguishers on board were not secured by suitable bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 19 August 2022
Resolution: Replaced brackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including operational test of the means provided for pumping bilges. Bilge strainer in Bow Thruster space is rusted effecting operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 19 August 2022
Resolution: Replaced strainer
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 23 June 2022 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Two windows on second deck are shattered and require replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 1 September 2022
Resolution: Received photographs of fixed windows
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2021 Resolved
46 CFR 182.05-1(a): Propulsion Machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. Vessels Stbd generator's sea water overboard pipe has several small holes in it that need to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 3 June 2021
Resolution: Operator repaired the pipe at Bay ship and reinstalled it in accordance with original specs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 June 2020 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions. Stbd fwd port hole gasket is deteriorated and the knife edge is corroded. 46 CFR 116.1020
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 28 July 2020
Resolution: Verified gasket was replaced as necessary.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2020 Resolved
Spanner wrenches must be provided for each fire hydrant required by this regulation. Galley fire station did not have a spanner wrench. 46 CFR 118.310(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Verified galley fire station included a spanner wrench.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 June 2020 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements. Vessel must remove extension cord in galley stores on port side. 46 CFR 120.340(r)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 15 July 2020
Resolution: Verified extension cord in galley stores was removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 June 2020 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements. Vessel must remove loose outlet that is run from an extension cord adjacent to fuel tank in the engine room. 46 CFR 120.340(r)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 15 July 2020
Resolution: Verified extension cord was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2020 Resolved
All microprocessor or computer based systems must meet the requirements. Main engine control cables were run through conduit held up by string and roughly taped together through galley stores. Vessel is also required to provide details of PTSP/DVTP. 46 CFR 121.620(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 29 July 2022
Resolution: Completed approved DVTP/QFA/PSTP.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 9 June 2020 Resolved
At each inspection for certification and at every other vessel inspection, galleys and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Galley space and food stores require thorough sanitizing. 46 CFR 115.818
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 28 July 2020
Resolution: Verified the galley and food stores was properly santized.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 June 2020 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Galley stores does not have adequate emergency lighting. 46 CFR 120.432
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Verified galley has satisfactory emergency lighting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 June 2020 Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Identified broken window on the port side of the Clerestory deck. 46 CFR 116.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 19 May 2021
Resolution: Verified window was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2020 Resolved
Each stowage container for life jackets must not be capable of being locked and must be designed to allow the life jackets to float free. Discovered miscellaneous items blocking access to life jackets from the forward Clerestory deck life preserver cabinet. 46 CFR 117.78(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: All miscellaneous items removed from PFD locker.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 June 2020 Resolved
A fire damper shall be made accessible for periodic inspection by means of a hinged or bolted plate in the duct. Discovered the stbd galley fire damper on the Clerestory deck stuck in one position and not easily accessible. 46 CFR 177.10-5(a) [Old T] and 46 CFR 72.05-50(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Verified fire damper works properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 June 2020 Resolved
Doors shall have a latch with a minimum throw of 3/4 inch which can be operated from either side of the door. Port and stbd galley doors located on the main deck do not latch closed. 46 CFR 177.10-5(a) [Old T] and 46 CFR 72.05-25(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 18 January 2022
Resolution: VSL is replacing WTD during current drydock.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Access / structural features (ship)
Issued 9 June 2020 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT, KEEP CLEAR." Galley machinery space door and engine room emergency escape hatch do not have labels and are covered by a heavy piece of plywood. 46 CFR 122.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 28 July 2020
Resolution: Received documentation from vessel rep displaying the correction of the emergency exit lettering on the specified hatches and verified in person that the hatch can be lifted.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 June 2020 Resolved
Doors in bulkheads required to be Class A-60, A-30, or A-15 shall be of hollow steel or equivalent metal construction solidly filled with approved structural insulation capable of meeting the requirements for a Class A-15 bulkhead. Door down to food stores has handle that is not vapor tight and the center plate has a cutout that does not allow for a proper seal. 46 CFR 177.10-5(a) [Old T] and 46 CFR 72.05-25(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 28 July 2020
Resolution: Verified the door was made vapor tight and the handle was replaced and properly installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2020 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician and issued a Communications Act Safety Radiotelephony Certificate. Testing of vessel's required EPIRB was not indicated on vessel's FCC Radiotelephony Certificate. 46 CFR 121.502 and 47 CFR 80.1105(k).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Verified FCC technician reprinted and signed certificate for EPIRB installation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 June 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel does not have updated charts onboard. 46 CFR 121.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Verified chart corrections were performed and noted for 2020.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 June 2020 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Discovered three missing required distress signals. Vessel is restricted to a Lakes, Bays, and Sounds route. 46 CFR 117.68(a)(b)
Action required: 705 - Other - as specified
Due 9 June 2020
Resolved 15 July 2020
Resolution: Verified all required smoke distress signals were in place for required route.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspections of the hull structure and its appurtenances, including inspection of the condition of the superstructure and similar arrangements constructed on the hull. Identified numerous cracked and wasted welds on bench seating support brackets, located in the after Clerestory deck. Due by next credit drydock. 46 CFR 115.802
Action required: 705 - Other - as specified
Due 31 January 2022
Resolved 28 July 2020
Resolution: Verified all broken welds were properly re-welded.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 June 2020 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Identified top and middle lifefloats in the aft port stack with exposed fiberglass, thereby reducing design capabilities. 46 CFR 115.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 15 July 2020
Resolution: Verified lifefloats were properly patched and in good condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 March 2019 Resolved
Auxiliary machinery, piping and pressure systems must be suitable for the vessel and its operation. The hydraulic lines for the bow prop is weeping hydraulic fluid. Hydraulic lines on bow prop must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2019
Resolved 19 April 2019
Resolution: New hydraulic lines on bow thruster installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion or machinery failure. Fuel drips were identified on the supply line for the starboard engine. Excessive elbow and valve must be removed and pipe capped off.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 28 March 2019
Resolution: Photo submitted showing elbow, valve, and excess piping removed and capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion or machinery failure. Observed drips of coolant from port MDE. Leaking coolant line was be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 3 April 2019
Resolution: Coolant leak was welded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 March 2019 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation. Capstan oil line was repaired with an unauthorized epoxy patch. Oil line must be repaired with metallic materials consistent with original pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 31 January 2020
Resolution: Oil line was replaced to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 March 2019 Resolved
Construction and arrangement of a vessel must allow means of escape in case of a sudden unexpected casualty. Both exits in engine room were not adequately lite during loss of power. Both exits must be adequately lite to assist in escape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 19 April 2019
Resolution: New lights installed in engine room, conducted test with vessel rep, lights are sufficient to illuminate engine room exit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 March 2019 Resolved
Power fire pump shall be fitted with a pressure gauge. Install gauge in fire pump to read line pressure. Current gauge reads zero to 100 PSI, clocks past limit of gauge unable to tell operating pressure. (Old T)181.10-1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2019
Resolved 3 April 2019
Resolution: Pump gauge was installed that is capable of reading pressure of the pump
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2019 Resolved
Individual wires, rather than cables, are used in systems greater than 50 volts, the wire must be in conduit. Exposed wiring on top of AC enclosure. Wire must be secured into the conduit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 March 2019
Resolved 28 March 2019
Resolution: Corrected on spot.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 March 2019 Resolved
Combustibles and other foreign materials are not allowed within ventilation ducts. Grease system in galley exhaust fan, and upper vent system inundated. Clean excessive grease from vent hood fan and at exhaust stack discharge fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 3 April 2019
Resolution: Excessive grease was cleaned in vent hood
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 March 2019 Resolved
Vapor tight barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids are present. Abounded wire runs from water heater to pantry space is missing vapor tight materials. Vapor tight barrier must be installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2019
Resolved 19 April 2019
Resolution: Vapor tight barrier installed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 March 2019 Resolved
Marine inspector shall inspect the hull structure and appurtenances including conditions of arrangements in the hull. Fore peak ladder lower bracket wasted. Bracket must be cropped and renewed. 46 CFR 176.25-5(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 January 2020
Resolution: Bracket repaired during 2020 dry dock to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 26 March 2019 Resolved
All electrical installations shall be to the satisfaction of the OCMI. The vessels starboard side gunwale electric control equipment, three junction motor control boxes, were found abandoned and damaged. Motor control boxes must be removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 January 2020
Resolution: The electrical components have been blanked off with the circuitry removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
Added 1 APR: 46 CFR 56.60-25 non-metallic flexible hose must be in accordance with J 1942. Main Diesel engines jacket water (keel cooled) hoses must meet the SAE J 1942 standard. The hoses observed are pretty thin and flexible (collapsible) and could not be matched to any standard. They must be replaced with appropriate hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 13 April 2020
Resolution: Received pictures of properly installed and authorized hoses on engines.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 5 October 2018 Resolved
NAME: Vsl is broadcasting incorrect Name -> currently broadcasting CALIFORNIA HORNBLOWE, needs to be changed to CALIFORNIAHORNBLOWER
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 June 2020
Resolution: Verified via NAVCEN's website that vessel corrected outstanding AIS error.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 March 2018 Resolved
Install metal wiring supports at an interval of 24". 183.340(a)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 10 April 2018
Resolution: Operator provided pictures of completion
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 March 2016 Resolved
Identify the cause of the leaks in the hydraulic steering system and repair to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 26 May 2016
Resolved 27 May 2016
Construction/Loadline › Hull › Hull Plating
Issued 28 February 2016 Resolved
Properly repair inset on tonnage opening on tonnage opening port side, midship, appx 10ft above waterline prior to credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 June 2016
Resolution: Repairs completed.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 11 April 2012 Resolved
1. Replace or repair to original- starboard generator exhaust expansion joints prior to personnel entering lazarette while engine is in use. *Power ventilation must be maintained underway until replacement or repairs have been made. 46CFR119.430. Due 16APR2012.
Condition: Improper/Lack of Maintenance
Due 16 April 2012
Resolved 17 April 2012
Communications › Internal Communications System › Engine Order Telegraph System
Issued 27 July 2011 Resolved
PROVE PROPER OPERATION OF THE PROPULSION SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, AND PROVIDE SIGNED COPY OF TECHNICIANS REPORT
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: Propulsion issue was loss of throttle response due to an invalid throttle signal. After inspection by CAT tech reps and CG Marine Inspectors, issue could not be duplicated and cause could not be determined. Domestics Chief authorized clearance of 835.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 22 March 2010 Resolved
Prove proper operation of the steering gear and rudder angle indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2010
Resolution: Operator proved that the rudder angle indicator operates correctly. The cause of the incident was due to a breaker that was was opened.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 6 March 2010 Resolved
Provide proof of operation #1 Ship Service Generator upon completion of repairs by authorized technicians. Tech report to be provided to USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2010
Resolved 7 March 2010
Resolution: Caterpillar engine technicians attended vessel, performed trouble shooting and determined high pressure fuel pump to be the cause of the failure. Pump replaced engine tested under load with satisfactory results.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 March 2010 Resolved
Provide proof of operation in way of calibration and or replacement, all meters in the ship service generator switchboard. Requirement correction date extended out to 28APR10, scheduled date for vessel's annual inspection.
Action required: 705 - Other - as specified
Due 28 April 2010
Resolved 28 April 2010
Resolution: Demonstrated proper operation of all generator meters.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 March 2010 Resolved
Provide and adjust packing for the port propulsion shaft.
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 10 March 2010
Resolution: Deficiency cleared based on verbal and written report provided by vessel’s port engineer.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 23 March 2009 Resolved
Install proper conduit into port galley electrical distribution panel
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 28 April 2010
Resolution: Electrical cable rerouted and properly enters distribution panel
Engineering › Thrusters › Pump
Issued 23 March 2009 Resolved
Complete repairs and prove proper operation of vessel bow propulsion/thruster unit
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 28 April 2010
Resolution: Bow thruster unit operated properly.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 March 2009 Resolved
Provide proper exhaust lagging from engine block to water injection inlet on both main engines and both generators
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 28 April 2010
Resolution: Exhaust lagging properly installed. One missing piece on #2 Generator was addressed in new CG-835.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 March 2009 Resolved
renew retroreflective tape on several life jackets
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 23 March 2009
Resolution: replaced defective tape wit new
Documentation › Logs/Records › Drug Test Records
Issued 8 June 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Due 3 July 2007
Resolved 12 June 2007
Resolution: New employee''s names will be added to the company''s consortium''s random drug testing list prior the employee acting in a safety sensitive position.
Documentation › Logs/Records › Drug Test Records
Issued 8 June 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Due 3 July 2007
Resolved 12 June 2007
Resolution: Random drug tests will no longer be waived.
Stability › Watertight Integrity › General
Issued 26 March 2007 Resolved
Replace 6 missing dogs on port water lights in galley space, port side.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 6 June 2007
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 26 March 2007 Resolved
Repair electric wire to galley fire door release.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 26 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2007 Resolved
Replace missing light cover in engine room, starboard side.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 26 March 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 March 2007 Resolved
Repair/renew port generator exhaust lagging, outboard.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 6 June 2007
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 26 March 2007 Resolved
Replace missing insulation on overhead in bow thruster compartment, port side below the galley space.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 6 June 2007
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 26 March 2007 Resolved
Repair/replace two water heaters in forward machine space.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 6 June 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 March 2007 Resolved
Provide updated coast pilot and light list.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 26 March 2007
Fire Fighting › Fire Hoses › Location
Issued 26 March 2007 Resolved
Make fire station 6 easily accessible by crew.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 26 March 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 26 March 2007 Resolved
Label emergency exit below ships office.
Due 26 March 2007
Resolved 26 March 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 March 2007 Resolved
Move the lifejacket donning placard to location to a lifejacket storage area.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 26 March 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 March 2007 Resolved
Replace 3 lifejackets, and renew retro reflective tape on 30 identified lifejackets.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 26 March 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 26 March 2007 Resolved
Mark upper deck with maximum number of passengers allowed IAW vessel stability letter.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 26 March 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 26 March 2007 Resolved
Prove proper operation of lighting in emergency exit sign on third deck.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 26 March 2007
Fire Fighting › Structural - Horizontal Zones › General
Issued 23 May 2006 Resolved
Repair Structural Fire Protection insulation in way of overhead of STBD MDE.
Due 23 June 2006
Resolved 26 July 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 May 2006 Resolved
Install sea rails on cooking range in galley IAW 46CFR 121.220(e).
Due 23 June 2006
Resolved 26 July 2006
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 23 May 2006 Resolved
Properly install insulation blanket over both MDE turbo's.
Due 23 June 2006
Resolved 26 July 2006
Engineering › Fuel Oil Service System › Hose
Issued 23 May 2006 Resolved
Replace chaffed F/O hose with CG approved J1942 standard hose in way of port MDE secondary fuel filter to F/O pump.
Due 23 June 2006
Resolved 26 July 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 May 2006 Resolved
Provide electrical plans for the installation of the bilge high level alarms at operating station to the attending CG Marine Inspector for approval prior to installation.
Due 23 June 2006
Resolved 21 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 May 2006 Resolved
Properly install bilge high level alarms at operating station IAW 46CFR 119.530 after receiving confirmation of approved plans.
Due 23 June 2006
Resolved 21 June 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 May 2006 Resolved
Renew retro reflective tape on 4 child PFD and 1 adult PFD.
Action required: 705 - Other - as specified
Resolved 23 May 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 May 2006 Resolved
Properly mark 1 adult PFD with vessels name.
Action required: 705 - Other - as specified
Resolved 23 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 23 May 2006 Resolved
Properly dead end electrical wire in way of engine room, port side aft.
Action required: 705 - Other - as specified
Resolved 23 May 2006
Construction/Loadline › Structures › Superstructure
Issued 21 April 2006 Resolved
Prove weather tightness of new window installation on stbd side of main deck.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 23 May 2006
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 4 April 2005 Resolved
Prove proper operation of air receiver relief valve in way of engine room inboard starting air receiver.
Due 15 April 2005
Resolved 5 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2005 Resolved
Properly dead end electrical wire in way of engine room by OWS.
Action required: 705 - Other - as specified
Resolved 4 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2005 Resolved
Properly connect electrical submersible bilge pump in way of port shaft.
Action required: 705 - Other - as specified
Resolved 4 April 2005
Lifesaving › Hand Flares › Expired
Issued 4 April 2005 Resolved
Renew four night flares.
Action required: 705 - Other - as specified
Resolved 4 April 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 4 April 2005 Resolved
Install one more child type one PFD to focsle bench storage.
Action required: 705 - Other - as specified
Resolved 4 April 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 March 2004 Resolved
Properly attach lifefloat pendant to lifefloats.
Action required: 705 - Other - as specified
Due 22 March 2004
Resolved 22 March 2004
Resolution: Corrected prior to inspection completion.
Engineering
Issued 16 March 2004 Resolved
Find the source of the exhaust leak(s) in way of the exhaust piping in the steering gear compartment both port and starboard. Submit repair proposal for approvial prior to starting repairs.
Action required: 705 - Other - as specified
Due 19 March 2004
Resolved 18 March 2004
Resolution: Findings faxed to SFCMS office confirming expansion joint leakage and wasted gasket in way of portside port side exhaust. Approved replacement in kind.
Electrical › Electric Generation Source (service)
Issued 7 April 2003 Resolved
Install di-electric matting in front of main switch board. LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 6 May 2003
Resolution: Installed di-electric mat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 April 2003 Resolved
Renew generator starter cable on both engines using approved cable. LEGACY COMPONENT DESC: Gear/Clutch Starter (electric)
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 6 May 2003
Resolution: Installed marine grade starter cable on engines.
Engineering › Lubricating Oil Storage/Transfer System
Issued 7 April 2003 Resolved
Remove dirty oil transfer pump outside controller or repair as new.
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 6 May 2003
Resolution: Removed transfer pump.
Pollution Prevention/Response › Prevention Equipment
Issued 7 April 2003 Resolved
Repair as new drain plugs in way of port and starboard fuel oil containment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 6 May 2003
Resolution: Installed drain plugs.
Electrical › Electric Generation Source (service)
Issued 1 April 2002 Resolved
Prove proper operation of overspeed trips for port & stbd generators. LEGACY COMPONENT DESC: overspeed
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 26 April 2002
Resolution: Sat test of 75% overspeed for Cummins.
Construction/Loadline › Structures
Issued 1 April 2002 Resolved
Replace broken window on Capt's Lounge deck port side forward. LEGACY COMPONENT DESC: Windows
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 26 April 2002
Resolution: Renewed
Engineering › Thrusters
Issued 1 April 2002 Resolved
Repair hydraulic oil leak on stbd generator bow thruster pump. LEGACY COMPONENT DESC: Seal
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 26 April 2002
Resolution: New gasket installed IWO hydraulic pump sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 1 April 2002 Resolved
Repair inoperable light for illumination of magnetic compass.
Due 1 April 2002
Resolved 1 April 2002
Fire Fighting › Fire Hoses
Issued 1 April 2002 Resolved
Provide spanner wrenches are provided for fire stations #2 and #4.
Due 1 April 2002
Resolved 1 April 2002
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 April 2002 Resolved
Provide a vent screen for port fuel tank.
Due 1 April 2002
Resolved 1 April 2002
Documentation › Logs/Records
Issued 1 April 2002 Resolved
Properly log monthly EPIRB Tests. LEGACY COMPONENT DESC: EPIRB Test Log
Due 1 April 2002
Resolved 1 April 2002
Engineering
Issued 1 April 2002 Resolved
Plug open valves above water heaters located in forward machinery space. LEGACY COMPONENT DESC: Water Heaters
Due 1 April 2002
Resolved 1 April 2002
Construction/Loadline
Issued 1 December 1998 Resolved
Make vessel's marine sanitation device tank open, gas free and available for internal examination by a USCG inspector.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Documentation
Issued 8 April 1996 Resolved
PROVIDE COPY OF UPDATED CERTIFICATE OF DOCUMENTATION WITH CURRENT OWNER ADDRESS.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Construction/Loadline
Issued 8 April 1996 Resolved
PAINT HOMEPORT OF VESSEL ON STERN AS REQUIRED BY VESSEL DOCUMENTATION REGULATIONS.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Electrical
Issued 31 May 1994 Resolved
PERMANENTELY WIRE 110V SUPPLY TO WATER SOFTENER SYSTEM.
Condition: Unknown
Due 21 June 1994
Resolved 5 July 1994
Engineering
Issued 31 May 1994 Resolved
INVESTIGATE & REPAIR LEAK IN LUBE OIL LINE TO BOW THRUSTER IN FOREPEAK OVERHEAD.
Condition: Unknown
Due 21 June 1994
Resolved 5 July 1994
Electrical
Issued 31 May 1994 Resolved
REPLACE ALL WIRE NUTS WITH CRIMPED OR SOLDERED ELECTRICAL CONNECTIONS IN WIRING & SWITCHBOXES IN FORWARD REFER SYSTEM STARBOARD SIDE.
Condition: Unknown
Due 21 June 1994
Resolved 5 July 1994
Electrical
Issued 10 January 1994 Resolved
MAKE ARMORED CABLE AT SHORE POWER CONNECTION BOX IN PANTRY PORTSIDE FORWARDELECTRICALLY CONTINUOUS WITH REGARD TO ARMOR/BOX CONNECTION.
Condition: Unknown
Due 17 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 10 January 1994 Resolved
MAKE WATERTIGHT FOUR TUBING PENETRATIONS OF WATERTIGHT BULKHEAD BETWEEN PANTRY AND FORWARD MACHINERY SPACE STARBOARD SIDE OUTBOARD.
Condition: Unknown
Due 17 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 10 January 1994 Resolved
REMOVE HYDRAULIC OIL RESIDUE FROM BILGES IN BOW THRUSTER COMPARTMENT.
Condition: Unknown
Due 17 January 1994
Resolved 14 January 1994
Lifesaving
Issued 13 April 1993 Resolved
CONDUCT A MAN OVERBOARD DRILL WITH CREWMEMBERS OF SUFFICIENT NUMBER TO COMPLETE A SUCCESSFUL DRILL. THIS DRILL MUST BE DONE WITH THE SAN FRANCISCO BASED CALIFORNIA HORNBLOWER CREW BUT CAN BE DONE USING THE VESSELLORD HORNBLOWER...NOTE: TO BE DONE AND CLEARED BY MSO SAN FRANCISCO, CA.
Condition: Unknown
Due 13 April 1993
Resolved 14 May 1993
Lifesaving
Issued 14 April 1992 Resolved
PROVIDE PROPER MARKING FOR ALL LIFEJACKET STOWAGE.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Fire Fighting
Issued 14 April 1992 Resolved
PROVE PROPER OPERATION OF HALON SYS. COMPLETE PRIOR TO DEPARTING SFB AND/OR TAKING PASSENGERS.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Fire Fighting
Issued 18 April 1991 Resolved
SERVICE REMOTE FIXED HALON RELEASE IN PILOT HOUSE.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Documentation
Issued 18 April 1991 Resolved
PROVIDE ONBOARD A CURRENT RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Fire Fighting
Issued 18 April 1991 Resolved
PROPERLY MOUNT B-II FIRE EXTINGUISHER IN PANTRY.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Accommodation/Occupational Safety
Issued 18 April 1991 Resolved
PROPERLY SECURE GRATING IN GALLEY ON DECK TO PREVENT A TRIPPING HAZARD.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Fire Fighting
Issued 18 April 1991 Resolved
PROVE PROPER OPERATION OF THE FIRE DOOR LEADING FROM PANTRY TO THE GALLEY AND ON THE STBD AFT MAIN DECK, DOORS SHALL REMAIN CLOSED UNTIL REPAIRED ANDROVING PATROLMAN SHALL ENSURE THEIR CLOSURE.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Navigation
Issued 18 April 1991 Resolved
PROVIDE ONBOARD AN ADDITIONAL ANCHOR.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Fire Fighting
Issued 3 July 1990 Resolved
PROVIDE ROVING PATROLMAN UNTIL USCG APPROVED MASTER CONTROL PANEL, FIRE ALARM AND BELL/CLOCK PRINTED CIRCUIT BOARDS, POWER SUPPLY, AND POWER TRANS-FER RELAY ARE INSTALLED IN FIRE/SMOKE DETECTION SYSTEM IN ACCORDANCE WITH G-MSC-2 LETTER SERIAL E-00090 DATED 21 FEBRUARY 1990.
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Engineering
Issued 18 May 1990 Resolved
SECURE LEAK ON STBD SHAFT PACKING. REPAIR IS TO BEGIN NLT 30FEB92.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Documentation
Issued 3 May 1990 Resolved
PROVIDE CORRECT FCC RADIO STATION LICENSE AND RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Fire Fighting
Issued 3 May 1990 Resolved
SERVICE FIXED FIRE FIGHTING SYSTEM FOR ENGINE ROOM AND GALLEY HOOD.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Fire Fighting
Issued 3 May 1990 Resolved
REPAIR FIRE SCREEN DOOR CLOSURE ON CLERESTORY DECK.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Electrical
Issued 3 May 1990 Resolved
REMOVE 16 GAUGE WIRING IN THE GALLEY OVERHEAD AND REMOVE EXTENSION CORD WIRING IN THE MACHINERY SPACE AFT OF PANTRY.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Accommodation/Occupational Safety
Issued 3 May 1990 Resolved
REPLACE HOSE ON SUBMERSIBLE BILGE PUMPS AT PROPELLOR SHAFT GLANDS WITH COAST GUARD ACCEPTABLE HOSE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Lifesaving
Issued 3 May 1990 Resolved
REPLACE ONE BROKEN LIFE FLOAT PADDLE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Fire Fighting
Issued 3 May 1990 Resolved
CLEAR ACCESS TO FIRE HOSE STATION #6 IN GALLEY.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Accommodation/Occupational Safety
Issued 3 May 1990 Resolved
PERMANENTLY MOUNT AND WIRE THE GALLEY TRASH COMPACTOR.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Fire Fighting
Issued 3 May 1990 Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Documentation
Issued 3 May 1990 Resolved
PROVIDE VALID COAST GUARD VESSEL DOCUMENT.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Accommodation/Occupational Safety
Issued 3 May 1990 Resolved
CLEAN ALL GALLEY VENT HOODS.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Documentation
Issued 3 May 1990 Resolved
RELOCATE ALL EMERGENCY CHECK-OFF LISTS TO POSITIONS ACCESSIBLE TO PASSENGERS.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Construction/Loadline
Issued 3 May 1990 Resolved
SEAL 4 OPEN PIPES IN AFT ENGINE ROOM BULKHEAD, INSIDE PORT ENGINE ROOM VENTDUCT.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Navigation
Issued 3 May 1990 Resolved
PROVIDE NAVIGATIONAL PUBS - TIDE TABLE, CURRENT TABLE AND LIGHT LIST.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Fire Fighting
Issued 26 September 1989 Resolved
ON GALLEY ENTRANCE FIRE SCREEN DOORS, INSTALL PROPER HANDLES AND LATCHES, OR OBTAIN PLAN APPROVAL FOR AUTOMATIC DOOR OPENERS FROM G-MSC AS PER 46 CFR72.05-25, AND DEMONSTRATE SATISFACTORY OPERATION OF SAME.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Construction/Loadline
Issued 26 September 1989 Resolved
REMOVE SUFFICIENT WOOD TRIM AND MOLDING ON MAIN DECK LOUNGE, CORRIDORS AND STAIRWAY ENCLOSURES TO MEET THE MAXIMUM VOLUME OF COMBUSTIBLES ALLOWED.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Lifesaving
Issued 15 August 1989 Resolved
PROVIDE ADDITIONAL LIFE FLOATS FOR 14 PERSONS. VESSEL IS LIMITED TO CARRY NO MORE THAN 672 PERSONS WHILE OPERATING ON LIMITED COASTWISE ROUTE.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Construction/Loadline
Issued 9 June 1989 Resolved
CG-835 ITEM #3 ISSUED BY MSO MOBILE AMENDED TO ALLOW OPERATION OF VESSEL WITH PASSENGERS PROVIDED A DESIGNATED ROVING FIRE PATROL IS MAINTAINED. THIS PATROL TO REMAIN IN EFFECT UNTIL THE ISSUE OF COMBUSTIBLE MATERIAL ON THE MAIN SALOON DECK AND STAIRWELL IS RESOLVED.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Lifesaving
Issued 9 June 1989 Resolved
THE TOTAL NUMBER OF PERSONS ON BOARD IS RESTRICTED TO A TOTAL OF 1002 PERSONS DUE TO CAPACITY OF PRIMARY LIFESAVING DEVICES OR LESS BASED ON RESULTS OF STABILITY TEST.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Fire Fighting
Issued 9 June 1989 Resolved
INSTALL MAGNETIC RELEASE ON FIRE SCREEN DOOR ON FORWARD CAPTAIN'S LOUNGE STAIRWAY.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Fire Fighting
Issued 9 June 1989 Resolved
LABEL GALLEY FIXED FIREFIGHTING SYSTEM IN GRILL HOOD FOR OPERATION.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Engineering
Issued 9 June 1989 Resolved
INSTALL PRESSURE RELIEF DEVICE OR NON-ADJUSTING REGULATORS ON WATER SYSTEM HYDRO CELLS FOR MAWP OF 70 PSI.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Accommodation/Occupational Safety
Issued 9 June 1989 Resolved
LABEL EXTERIOR OF FORWARD MACHINERY SPACE EMERGENCY ESCAPE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Fire Fighting
Issued 9 June 1989 Resolved
REPAIR OR ADJUST FIRE SCREEN DOORS AT PORT CLERESTORY DECK AND STARBOARD STERN MAIN DECK TO ALLOW FOR PROPER CLOSURE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Accommodation/Occupational Safety
Issued 9 June 1989 Resolved
SECURE REFRIGERATION PRESSURE REGULATORS IN FORWARD MACHINERY SPACE WITH METALLIC BANDING.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Accommodation/Occupational Safety
Issued 9 June 1989 Resolved
INSTALL MACHINERY GUARD ON COOLING WATER PUMP IN MACHINERY SPACE AFT OF FRAME 33.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Construction/Loadline
Issued 9 June 1989 Resolved
INSTALL LOCK ON WATERTIGHT DOOR IN WATERTIGHT BULKHEAD AT FRAME 33 (TO REMAIN LOCKED WHILE UNDERWAY).
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Documentation
Issued 6 May 1989 Resolved
POST STABILITY LETTER ON BOARD.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Lifesaving
Issued 6 May 1989 Resolved
PROVIDE SUITABLE RESCUE BOAT, OR DEMONSTRATE THAT VESSEL ITSELF IS A FULLY SATISFACTORY RESCUE PLATFORM.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Construction/Loadline
Issued 6 May 1989 Resolved
REMOVE SUFFICIENT WOOD TRIM AND MOLDING IN MAIN DECK LOUNGE, CORRIDORS AND STAIRWAY ENCLOSURES TO MEET THE MAXIMUM VOLUME OF COMBUSTIBLES ALLOWED.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Lifesaving
Issued 6 May 1989 Resolved
PROVIDE SUFFICIENT LIFE PRESERVERS FOR THE TOTAL NUMBER OF PERSONS ALLOWED BY THE STABILITY LETTER.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Construction/Loadline
Issued 6 May 1989 Resolved
GAS FREE AND RESTORE AFT BALLAST TANK TO ITS INTENDED SERVICE.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Documentation
Issued 6 May 1989 Resolved
OBTAIN AND POST ON BOARD VALID FCC STATION LICENSE AND SAFETY CERTIFICATE.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Construction/Loadline
Issued 6 May 1989 Resolved
ON GALLEY ENTRANCE FIRE SCREEN DOORS, INSTALL PROPER HANDLES AND LATCHES, OR OBTAIN PLAN APPROVAL FOR AUTOMATIC DOOR OPENERS, AND DEMONSTRATE SATISFACTORY OPERATION OF SAME.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989

Casualty record · 11

26 February 2006Routine · role: Involved in a Marine Casualty · activity 2601638
19 November 2006Routine · role: Involved in a Marine Casualty · activity 2826223
3 December 2006Routine · role: Involved in a Marine Casualty · activity 2835553
7 March 2010Routine · role: Involved in a Marine Casualty · activity 3692136
22 May 2011Routine · role: Involved in a Marine Casualty · activity 4019940
27 July 2011Routine · role: Subject to Coast Guard Operational Control · activity 4109430
27 February 2016Routine · role: Involved in a Marine Casualty · activity 5825059
30 April 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6139106
25 April 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7308686
28 October 2023Routine · role: Involved in a Marine Casualty · activity 7821461
7 March 2026Routine · role: Involved in a Marine Casualty · activity 8323234
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.