Records from 2009 to 2021. Most recent: inspection, 12 November 2021.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)105.4 ft × 30.0 ft × 5.4 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN RI, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
15 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
12 November 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7349650
29 April 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7185800
20 January 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7127605
27 November 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7102602
6 January 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6883811
4 June 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6705051
2 April 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6654627
27 March 2019
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6650358
31 January 2018
COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6341453
10 January 2018
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6335487
25 October 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6295708
12 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6122459
17 February 2017
Hull Examination · Examination of Repairs · Plan Review "T" Boat · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6096150
31 May 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5893079
4 February 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5809889
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 January 2020
No resolution recorded
At each subsequent inspection, the marine inspector shall inspect all lifesaving equipment to determine its serviceability. Discovered various components of buoyant apparatus' with frayed waterlight lines and pendants, worn retroreflective tape, and worn paint on body of lifesaving appliances. 46 CFR 176.25-22(a) [Old T]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 January 2020
Resolved
Each launching appliance on a vessel must be visually inspected, inspected monthly using the manufacturer's instructions, and thoroughly inspected (with any necessary reapirs made) once each year. There was no record of any lifesaving inspections occuring at the required weekly, monthly, an annual interval. 46 CFR 122.720-726.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2020
Resolved 6 May 2020
Resolution: Received photos of required logged lifesaving equipment checks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2019
Resolved
Main distribution panels shall be the dead front type where voltage to ground is in excess of 150 volts A.C. or 250 volts D.C. The main electrical cabinet in the engine room has a blank cover plate on the panel.
46 CFR 183.10-15 (f)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 2 April 2019
Resolution: MI attended vessel for credit DD and witnessed the open breaker panel with appropriate cover plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2019
Resolved
Propulsion machinery shall be suitable in type and design for the propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Shaft packing on both port and starboard shafts in the engine room are leaking. Shaft packing must be secured prior to completion of next drydock.
46 CFR 182.05-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 1 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 March 2019
No resolution recorded
Except as provided in paragraph (f) of this section, each opening in a watertight bulkhead must have a means to close it watertight. Penetration in the side shell plating exists underneath the aft port-hole as well as under port-hole closest to the engine room door. Side shell penetrations must be repaired prior to completion of next drydock scheduled for 2021.
46 CFR 171.111 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2021 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Switch
Issued 31 January 2018
Resolved
Remove extension cords around bar area. 46 CFR120.372
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 31 January 2018
Resolution: Removed extension cord
Engineering › Pressure Vessel › Support
Issued 31 January 2018
Resolved
Secure CO2 bottles for bar soda machine 46 CFR 115.830
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 31 January 2018
Resolution: Properly secured CO2 bottles against shifting.
Lifesaving › Buoyant Apparatus › Marking
Issued 31 January 2018
Resolved
Stencil BA's with vessel name 46 CFR 122.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 31 January 2018
Resolution: Restenciled BA's with vessel name
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2018
Resolved
Replace unreadable emergency broadcast placard 46 CFR 121.506
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 31 January 2018
Resolution: Provided new broadcast placard to operator, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 October 2017
Resolved
Fixed CO2 systems on inspected vessels need to be type approved and installed in accordance with applicable regulations. Relocate the CO2 pressure switch outside of the protected space. Cite: 46CFR118.410(b)(1)(i), See MSIB 1512 for reference
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 21 December 2017
Resolution: Pressure Switch was relocated outside Engine Room. CO2 system test by Global Fire and Safety and is in Ready to use condition.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 12 April 2017
Resolved
Hydrostatic release for IBA expired.
Condition: Improper/Lack of Maintenance
Due 13 April 2017
Resolved 13 April 2017
Resolution: Rep provided photo proof of new hydro release.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 February 2016
Resolved
Remove scaling on 2nd deck outside passenger area; clean and identify extent of wasted areas of the deck. Make temp repairs to though deck holes to make safe until permanent repairs effected at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 12 April 2017
Resolution: Completed during DD.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 February 2016
Resolved
Remove scaling and clean bottom deck plating at stern stairwell of the 01 deck. Crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 12 April 2017
Resolution: Completed during DD.
Stability › Weathertight Integrity › General
Issued 4 February 2016
Resolved
Renew knife edge and gasket on 01 deck stern door to make weathertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 12 April 2017
Resolution: Completed during DD.
Stability › Weathertight Integrity › General
Issued 4 February 2016
Resolved
Make port and stbd doors to 2nd deck fan room weathertight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2019
Resolved 4 June 2019
Resolution: Port side door removed and plate inserted. Verified stbd door weathertight.
Stability › Weathertight Integrity › General
Issued 4 February 2016
Resolved
Crop and renew main deck port and stbd side double door framing to make weathertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 4 June 2019
Resolution: Verified newly installed port/stbd doors weathertight.
Construction/Loadline › Structures › Superstructure
Issued 4 February 2016
Resolved
Crop and renew wasted framing in the 02 deck fan room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 12 April 2017
Resolution: Completed during DD.
Construction/Loadline › Structures › Deck Plating
Issued 4 February 2016
Resolved
Provide UT guaging on the 02 passenger area and UT guaging at bottom deck plating of the 01 stern stairwell, prior to next required dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 12 April 2017
Resolution: Completed during DD.