SUPER EXPRESS is a 1989 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in February 2026, along with 15 deficiencies and 3 casualty investigations between 2008 and 2015.

Records from 2008 to 2026. Most recent: inspection, 11 February 2026.

Built
1989
Last inspected
11 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAB6372
330701
Flag
UNITED STATES
Maury page id
psix-330701

Documentation record

Registered dimensions (L × B × D)85.8 ft × 22.7 ft × 7.2 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD, INC. · WESTPORT, WA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

11 February 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8235629
13 June 2025 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8151094
15 January 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8004987
4 December 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024883
6 September 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981168
8 February 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845959
13 November 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7824280
13 November 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7824303
23 August 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7768355
3 March 2023 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7645277
2 February 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613505
29 July 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7498456
8 March 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7407882
13 January 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7378786
23 July 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7257959
25 March 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162615
25 March 2020 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6929764
23 January 2020 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6877252
12 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6617465
20 March 2018 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6368291
27 February 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350818
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314784
23 October 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6307698
13 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6082007
23 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5826276
11 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5813724

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2024 Resolved
Piping for fixed gas fire extinguishing system: Piping, valves, and fittings must be securely supported, and where necessary, protected against damage. MI identified damaged flexible rubber hose for installed halon fire suppression system. 46 CFR 181.410(d)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2025
Resolved 12 December 2024
Resolution: Receieved Breakwater International servicing certificate for replacement of Discharge Hose.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 December 2024 Resolved
Batteries-general: Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI identified battery terminal connections for port generator were secured with wing nuts. 46 CFR 183.350(d)
Action required: 10 - Deficiency Rectified
Due 5 December 2024
Resolved 5 December 2024
Resolution: Vessel replaced during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel must re-label the vessels name in clearly legible capital block letter on the 15 life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 14 February 2024
Resolution: Life Jackets have been re-labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel must re-label the vessels name in clearly legible capital block letter on the the port side ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 14 February 2024
Resolution: Ring Life Bouy has been re-labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 February 2024 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers:(2) On each life float and buoyant apparatus. Vessel must re-label the vessels name in clearly legible capital block letter on 04 port side life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 14 February 2024
Resolution: Life floats have been re-labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 February 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Vessel must re-label the vessels name in clearly legible capital block letter on the 16 life float paddles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 14 February 2024
Resolution: 16 Paddles have been re-labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 February 2024 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Housing on stbd side life float waterlight found cracked, replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 14 February 2024
Resolution: Light was replaced with new one.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 27 February 2018 Resolved
Make local manual controls on halon system accessible for maunal release and post instructions on operation for crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 1 March 2018
Lifesaving › Lifefloat › Float Free
Issued 27 February 2018 Resolved
Prove lifefloats are in float free arrangement. Connect all lights to floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Crew untangled all lines and connected lights to floats.
Engineering › Bilge Water Management System › Strainer
Issued 27 February 2018 Resolved
Provide strainers for bilge suction pipes that is at least three times the size of the bilge piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2018
Resolved 1 March 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 February 2018 Resolved
Prove proper operation of generator emergency fuel shutoff valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Valve handle was replaced and witnessed proper operation of emergency fuel shutoff valve.
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 27 February 2018 Resolved
Servicing report was inaccurrate and stated blow throughs were complete, blow throughs of the piping was not completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Witnessed third party conducting blow throughs of piping.
Engineering › Pressure Vessel › Relief Valve
Issued 27 February 2018 Resolved
Provide proper relief valve and prove proper operation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: crew installed new relief valve and witnessed proper operation.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 February 2017 Resolved
Ensure Light List is updated to reflect current list for area of operation.
Due 17 February 2017
Resolved 13 February 2017
Resolution: Def cleared.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 February 2016 Resolved
Repair two holes above waterline of aft forepeak hold bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2016
Resolved 11 February 2016
Resolution: Aluminum plate and sealing compound used to seal small holes.

Casualty record · 3

22 November 2008Routine · role: Involved in a Marine Casualty · activity 3375109
6 December 2013Routine · role: Acknowledged Pollution Source · activity 4771971
3 June 2015Routine · role: Involved in a Marine Casualty · activity 5148142
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.