Records from 2005 to 2024. Most recent: inspection, 27 February 2024.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 December 2023
Resolved
Fireboy system do not operate as designed. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 December 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 December 2023
Resolved
Unable to conduct drills due to fireboy system not operational. Once fireboy system is operational, must conduct Fire and MOB drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 December 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 July 2023
Resolved
A 42 inch crack was observed on the Port side, along midship, with an additional 6" x 5/8" open fracture.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2023
Resolved 2 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2023
Resolved
Conduct repairs to Main Diesel Engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2023
Resolved 12 June 2023
Resolution: Troubleshooting discovered faulty solenoid, replaced with new, function test successfully conducted.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 November 2022
Resolved
Fireboy system was last inspected Jan 2021 which expired Jan 2022. Annual servicing must be conducted prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2022
Resolution: Had the annual servicing completed today.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2022
Resolved
Several electrical wires were found undersized, laying in bilge and unsupported. All wiring other than indicating circuits must be 14 AWG or bigger. All wiring must be supported with metal brackets every 24 inches and as high out of the bilge as possible.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2022
Resolved 18 January 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 March 2022
Resolved
Vessel failed to have drydock inspection. Must complete drydock inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2022
Resolution: Conducted Drydock/ISE inspection
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 November 2021
Resolved
Life float paddles did not have the vessels name on them. Must have vessels name on each paddle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 10 December 2021
Resolution: Labeled paddles with vessels name. All SAT
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 November 2021
Resolved
Vessel does not have a CG approved NAV Chart onboard. Must provide CG approved NAV chart on board or update GPS to latest software/chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 10 December 2021
Resolution: Updated GPS with latest chart. All SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 10 November 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 10 December 2021
Resolution: Took course/test online and has FCC permit
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 November 2021
Resolved
Vessel does not have a valid FCC station license onboard vessel. Vessel must show proof of valid FCC Station License.
47 CFR 80
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 12 November 2021
Resolution: Email with FCC station license attached with experation date of 10-07-2024, all SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021
Resolved
Owner failed to conduct Coast Guard of overhauling vessel's main diesel engine and suffered a engine casualty on new overhauled engine with passengers onboard and had to be towed back to dock. Captain failed to notify Coast Guard of casualty. Once engine is overhauled or replace, vessel must under go engine alarm test's and conduct sea trials with Coast Guard Marine Inspector prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2021
Resolved 23 July 2021
Resolution: Conducted satisfactory sea trials. Cleared to operate with passengers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 October 2020
Resolved
Fire Boy system was found to be non-operational when initially tested.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 October 2020
Resolution: The crew swapped out the display head and controller on the spot and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 October 2020
Resolved
Both life floats were wasted and non-repairable. The inner seam had become dislodged from the foam material and allowed the inner core to become exposed to the elements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2020
Resolved 5 November 2020
Resolution: Two new life floats on board vessel and properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 October 2020
Resolved
During Internal Structure Exam, all four station tabbing’s attached to the transom had become separated from the transom. While sounding the stations, it gave indications that the wood had become wasted. A small amount of fiberglass that had separated was peeled back exposing the wood, and it revealed the wood was in fact wasted and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2020
Resolved 4 November 2020
Resolution: Repaired back to original
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 October 2020
Resolved
During Internal Structure Exam, tabbing around the exhaust flange that attaches to the transom bulkhead had separated approximately 1/16 of an inch. When the transom bulkhead above the exhaust flange was sounded, from the inside clear indications of delamination was present approximately 6”-8” above the flange. When sounded from the outside, indications led the inspector to believe the wood may be weakened or rotted. The representative’s plan is to grind the tabbing around the flange and the delaminated fiberglass on the transom, and examine the wood in the transom bulkhead for further planning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2020
Resolved 4 November 2020
Resolution: Repaired back to original
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 1 October 2019
Resolved
Life ring grab line is wasted. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: Life ring was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2019
Resolved
Vessel is required to carry 04 child PFD’s, currently missing 01. Replace 01 child PFD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2019
Resolution: New Child sized PFD was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2019
Resolved
All PFD w/ cracks and wear must be repaired/renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: All PFD have been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 October 2019
Resolved
Splice painter line to proper location, and stow grab lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: Painter was spliced to the proper loop, and all lines have been properly stowed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 October 2019
Resolved
Provide coast pilot and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: New publications were provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 October 2019
Resolved
Aft deck to transom connection on the STBD side is cracked and has slight water intrusion into the lazarette. Grind and repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: Aft deck near aft hatch has been cut out, new core installed and new glass was properly wetted in.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 October 2019
Resolved
Renew plastic cap in hull valve with metallic cap/plug
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: Abandoned valve has been capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Engine is missing forward cover. Provide and mount.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: New cover was installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2019
Resolved
Renew handrail hardware.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: All hardware was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2019
Resolved
Replace hardware on charge air cooler mount.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: All hardware was renewed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 October 2019
Resolved
Create/update to program to track monthly lifesaving maintenance and EPIRB testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2019
Resolution: New log program was created.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 10 January 2019
Resolved
Life ring grablines are wasted. Renew Liferings.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
Resolution: Renewed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2019
Resolved
Ground wire on fuel fill hose is missing. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
Resolution: Renewed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 January 2019
Resolved
Add survival craft maintenance to logs. Conduct monthly
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 April 2018
Resolved
No written Drug and Alcohol plan
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2018
Resolved 9 May 2018
Resolution: Corrections made to plan.
Lifesaving › Lifefloat › Float-free Link
Issued 11 April 2018
Resolved
WEAKLINK FOR LIFEFLOAT OVERSIZED, RESTRICTED TO OPERATION WITHON 100FT WATER
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 18 April 2018
Resolution: Changed weaklink to correct size.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2018
Resolved
PROVIDE WATER LIGHT FOR EACH LIFE FLOAT. REDUCED TOTAL PERSONS TO 20.
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 18 April 2018
Resolution: New batteries installed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 April 2018
Resolved
LABEL STOWAGE LOCATION FOR ADULT/CHILD PFD'S
Due 13 April 2018
Resolved 18 April 2018
Resolution: PFD's stowage locations labeled.
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 April 2018
Resolved
LABEL REMOTE SHUT OFF STATION
Due 13 April 2018
Resolved 18 April 2018
Resolution: Fuel shut offs labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2018
Resolved
FIRST AID KIT NOT IAW 46CFR160.041.
Condition: Improper/Lack of Maintenance
Due 18 April 2018
Resolved 23 April 2018
Resolution: First aid kit updated with all required contents.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2018
Resolved
VHF MUST BE GPS READY AND MMSI NUMBER INPUTED.
Due 11 May 2018
Resolved 18 April 2018
Resolution: New VHF installed with GPS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2018
Resolved
REMOVE ALL DEAD-END WIRING AND SUPPORT AT 24' INTERVALS FOR ACTIVE WIRES.
Condition: Improper Installation
Due 18 April 2018
Resolved 18 April 2018
Resolution: Dead-end wiring removed.
Engineering › Bilge Water Management System › Not Operational
Issued 11 April 2018
Resolved
ALL SUBMERSIBLE BILGE PUMPS MUST BE UL 1113 LISTED (FORWARD AND FUEL TANK COMPARTMENT)
Condition: Improper/Lack of Maintenance
Due 18 April 2018
Resolved 9 May 2018
Resolution: New Rule 2000 pump installed.
Engineering › Bilge Water Management System › Not Installed
Issued 11 April 2018
Resolved
ALL BILGE PUMPS MUST BE PERMANENTLY MOUNTED
Condition: Improper Installation
Due 13 April 2018
Resolved 9 May 2018
Resolution: Pumps permanently mounted.
Engineering › Bilge Water Management System › Valve
Issued 11 April 2018
Resolved
BILGE OVERBOARD DISCHARGE LINE MUST HAVE POSITIVE SHUT OFF VALVE (LAZERETTE)
Condition: Improper Installation
Due 18 April 2018
Resolved 18 April 2018
Resolution: New valve installed.
Fire Fighting › Fire Bucket › Availability
Issued 11 April 2018
Resolved
PROVIDE 3 2.5GALLON FIRE BUCKETS WITH LANYARDS.
Condition: Improper Installation
Due 13 April 2018
Resolved 18 April 2018
Resolution: New buckets onboard.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 April 2018
Resolved
PROVIDE VISUAL/AUDIBLE INDICATION FOR ALL HIGH WATER INDICATORS. (/ENG/)
Condition: Improper Installation
Due 18 April 2018
Resolved 23 April 2018
Resolution: Indicators corrected and labeled.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 April 2018
Resolved
PROVIDE VISUAL INDICATORS FOR ALL AUTOMATIC BILGE PUMPS. ENG ROOM
Condition: Improper Installation
Due 18 April 2018
Resolved 18 April 2018
Resolution: Indicators corrected.
Stability › Watertight Integrity › General
Issued 11 April 2018
Resolved
RENEW/REPLACE GASKET FOR FUEL TANK WATERTIGHT HATCH.
Condition: Improper/Lack of Maintenance
Due 13 April 2018
Resolved 18 April 2018
Resolution: Gasket replaced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2018
Resolved
REPLACE/RENEW PORTSIDE NAVIGATION LIGHT. VESSEL RESTRICTED TO DAYLIGHT OPS.
Condition: Improper/Lack of Maintenance
Due 18 April 2018
Resolved 18 April 2018
Resolution: New light installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2018
Resolved
REPLACE BATTERIES FOR FLOATING WATERLIGHTS. Restricted TO DAYLIGHT OPS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 18 April 2018
Resolution: New batteries installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 February 2018
Resolved
Engine room bulkhead has wires running aft that are not sealed. Seal all wire runs in the engine room.
Action required: 10 - Deficiency Rectified
Resolved 1 March 2018
Resolution: Wire runs were sealed with fire retardant putty.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 March 2017
Resolved
removed 12 adult and 1 child PFD due to foam failure within the PFD. Renew 12 adult and 1 child prior to carrying full COI complement.
Action required: 705 - Other - as specified
Resolved 21 March 2017
Resolution: New PFD were provided and properly marked.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 March 2017
Resolved
PFD are in a stowage box that had a line reel bolted into the top of the box. This nox makes the PFDs not accessible. Remove reel, or stow PFD in new more accessible location.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 March 2017
Resolved
Tank Space bilge alaarm is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2017
Resolution: New alarm panel was installed and tested all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 March 2017
Resolved
Lanyard on strobe is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Resolution: New lanyard was installed.
Lifesaving › Lifefloat › Painter
Issued 15 March 2017
Resolved
Life float painter line is not attached to the vessel via weak link. Repair.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Resolution: NEw weak link was provided and painter was attached.
Lifesaving › Lifebuoys › Stowage
Issued 15 March 2017
Resolved
Life ring strobe lanyard does not have a clip to allow for removal of light during daylight operations. Provide.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: NEw clip was provided and installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 March 2017
Resolved
Fire extinguishers do not have brackets and are not mounted. Provide approved brackets, and mount.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: New brackets were provided and mounted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 March 2017
Resolved
Vessel stern light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: Light was replaced and tested all sat.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 15 March 2017
Resolved
Vessel does not have a waste management plan. Provide and post.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: Plan was provided and posted.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 March 2017
Resolved
Emergency broadcast placard is not onboard. Provide and post near radio.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: Emergency placard was posted near radio controls.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 March 2017
Resolved
All PFDs need cleaning and retro replacement.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Resolution: PFDs were cleaned and new retro was installed.