Records from 1985 to 2026. Most recent: operational control imposed, 25 March 2026.
Inspection history · 84
25 March 2026
In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8331691
20 January 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8290121
20 December 2025
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8300789
16 December 2025
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8284284
23 January 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8067610
26 September 2024
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8001248
20 March 2024
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7883522
24 October 2023
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7813345
6 July 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7735713
9 February 2023
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7633828
26 October 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7583980
21 July 2022
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7512917
31 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7388389
23 July 2021
Damage Survey · Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7265207
30 April 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7191606
19 March 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7171213
1 February 2021
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7134278
26 October 2020
Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7084519
16 September 2020
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 7059916
16 September 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7060639
14 July 2020
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7006281
13 January 2020
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6888554
7 February 2019
Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6621458
31 October 2018
Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6571320
27 November 2017
COI Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6313101
30 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293413
18 January 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6107982
26 October 2016
Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6049399
23 February 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5818775
10 June 2012
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 4340212
23 February 2012
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4262690
30 December 2011
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 4216439
30 December 2011
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4218247
30 December 2011
Damage Survey · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4219231
14 January 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3926800
22 January 2010
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3698004
13 January 2009
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3393537
29 November 2007
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3106602
26 November 2007
Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3104598
25 March 2007
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2894531
25 March 2007
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 2894723
12 February 2007
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2870778
23 January 2007
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2859948
23 January 2006
Deficiency Check · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2571833
3 January 2006
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2559592
26 January 2005
Re-Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2277349
22 January 2004
Deficiency Check · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1993847
2 December 2003
Deficiency Check · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1956651
5 December 2002
COI Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1708457
8 January 2002
Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1477942
28 November 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1465078
16 February 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1058853
10 December 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436310
7 December 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436309
29 January 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790328
4 January 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807648
15 December 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1454613
20 January 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777552
16 December 1997
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1107850
10 December 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 860558
5 December 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193560
6 November 1995
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1192398
20 December 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1154546
30 December 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 849183
20 December 1993
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850246
29 November 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158621
11 March 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1153511
26 January 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 826419
21 July 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946769
22 January 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 941661
25 January 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301293
23 January 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301431
24 January 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253617
2 October 1989
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1224643
29 June 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1044122
18 January 1989
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 896313
21 January 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1027522
16 December 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1025875
26 January 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1009078
9 January 1987
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1327985
15 May 1986
Credit Drydock · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992654
29 January 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307803
27 February 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 979922
22 January 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 976344
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessel suffered minor electrical fire near the starboard diesel engines engine control module (ECM) resulting in the starboard engine inoperable.
Affect permanent repairs to the satisfaction of a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2026
Resolution: Technicians installed new engine wiring harness. Crew installed new battery switches and battery cables. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 January 2026
Resolved
Engine compartment high water alarm only has audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2026
Resolved
Hose clamps need to be replaced on Port fuel fill line to tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2026
Resolved
Bonding wires need to be fixed in Fuel tank Compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2026
Resolved
Life ring needs new retro tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 January 2026
Resolved
01 Fire bucket is missing its lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 January 2025
Resolved
On a vessel on which the number of passengers is permitted on the upper decks is limited by stability criteria, it shall be labeled with 1 inch letters at the entranceway to that deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 27 January 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 January 2025
Resolved
Repair AFT bilge high water alarm does have both audible and visual. Needs visible light to indicate high level.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 27 January 2025
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 23 January 2025
Resolved
Emergency procedures must be posted explaining crewmembers duties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 23 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 March 2024
Resolved
Lifeline attached to life ring found secured to fly bridge railing. Rendering the quick deployment of life ring compromised.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2024
Resolved 20 March 2024
Resolution: Lifeline was unsecured from railing and properly re-stowed to ensure immediate deployment.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 July 2023
Resolved
Vessel is required to have 12 emergency flares total. Minimum 6 have to be red. Vessel was found with 4 red flares with a total of 10 flares. Replace missing 2 flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2023
Resolved 2 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 July 2023
Resolved
Vessel is required to have a floating water light for each life float. Vessel was found with one of the two floating waters lights not working. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2023
Resolved 2 August 2023
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 February 2023
Resolved
Fuel shut off valves labeling was engraved on each bronze cap, making it very hard to see it. Paint engraved labeling with contrasting color so you can read it.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 28 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2022
Resolved
5 Adult life jackets were found in un serviceable condition. Must replace 5 adult life jackets. Total passenger count reduced by 5 until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 4 February 2022
Resolution: 5 new adult type 1 life jackets onboard and labeled with vessels name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2022
Resolved
90 Percent of life jackets had faded/worn reflective tape. Must replace all with SOLAS reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 4 February 2022
Resolution: All life jackets had retro tape replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2021
Resolved
Port MDE suffered a casualty during a dive trip on the way back to the dock. Must conduct repairs, conduct engine alarm test and satisfactory sea trials with CG Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2021
Resolved 10 September 2021
Resolution: Completed install and conducted satisfactory sea trials.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 February 2021
Resolved
No paper copy of Nav chart and GPS was not up to date. Up date Garmin GPS with latest software version or buy new paper copy CG approved chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 16 March 2021
Resolution: Garmin GPS software was updated to current version.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 February 2021
Resolved
No crew training log. Fire and MOB drills log only had date and time. Need to make crew training log and make new log for fire drills and MOB drills and log all required info.
46 CFR 185.420
46 CFR 185.520
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 16 March 2021
Resolution: Owner/ Operator created 1 log specifically for crew training. O/ O submitted last training log entry, containing required information for fire and MOB drills.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 February 2021
Resolved
Top life float is faded pretty bad. Must repaint lifefloat
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 16 March 2021
Resolution: Owner/ Operator repainted lifefloat with manufacturer's recommended paint, replaced retroflective tape with new tape.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 January 2020
Resolved
Fire boy audible and visual alarm are inoperable. Renew/replace
Action required: 705 - Other - as specified
Due 20 January 2020
Resolved 30 January 2020
Resolution: Fire boy audible and visual alarm was renewed from the factory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 January 2020
Resolved
Navigation lights are wasted. Renew/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2020
Resolution: Port and starboard navigation lights were replaced with new LED lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2020
Resolved
Replace reflective tape, and touch up name and paint on life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2020
Resolution: Life jackets have been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2020
Resolved
Replace sea painter on life raft with correct polypropylene line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2020
Resolution: Sea painter was renewed with proper size and length of polypropylene line.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 January 2020
Resolved
Renew/replace retro tape and write name and capacity on both sides of life raft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2020
Resolution: Retro, name and capacity were renewed on both sides.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2020
Resolved
Renew/replace life line strap on starboard life raft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2020
Resolution: Life line straps were renewed with new webbing.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 13 January 2020
Resolved
Renew/replace retro line on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2020
Resolution: Retro and line on the life ring has been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2020
Resolved
Replace life ring lanyard with proper line. 3’-6’ of 3/8 polypropylene line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2020
Resolution: Life ring lanyard has been renewed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 January 2020
Resolved
Renew beam on aft coaming on port engine boom hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2020
Resolution: Beam and coaming were repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2019
Resolved
08 Adult PFD's are wasted and must be replaced. Passenger count is reduced to no more than 40 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 7 February 2019
Resolved
Life float sea painter is wasted. Renew with proper line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2019
Resolution: Renewed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2019
Resolved
Update expired contents in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2019
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 February 2019
Resolved
Refective markings on safety gear must be renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2019
Resolution: All reflective material was renewed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 January 2017
Resolved
4 child PFD are no longer serviceable. Renew.
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 18 January 2017
Resolution: 4 new child PFD were placed into service.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 January 2017
Resolved
Several PFDs need new retro tape, and cleaning.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: PFD were cleaned, painted, and new retro installed.
Engineering › Steering Gear System › Fastener
Issued 18 January 2017
Resolved
Steering arm linkage bolt is worn and near failure. Renew bolt and associated hardware.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 25 January 2017
Resolution: New hardware was installed and tested.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 18 January 2017
Resolved
Vessel does not have a waste management plan. Provide.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 25 January 2017
Resolution: Waste management plan was provided.
Engineering › Fuel Oil Service System › Hose
Issued 23 February 2012
Resolved
Renew fuel hoses on Starboard Engine as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2012
Resolved 8 March 2012
Resolution: New hoses installed. All sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 February 2012
Resolved
Provide background check/consent forms for all crewmembers hired in the last three years.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 March 2012
Resolved 8 March 2012
Resolution: Provided background forms signed an filled out by employees. All sat.
Lifesaving › Lifefloat › Lifeline
Issued 23 February 2012
Resolved
Repair lifeline straps on starboard Lifefloat as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2012
Resolved 8 March 2012
Resolution: Preventive maintenance performed on lifeline straps.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 February 2012
Resolved
Renew lifeline on ring buoy, line is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2012
Resolution: New lifeline installed. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 January 2011
Resolved
Properly mark life jacket storage area with size and number of life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 19 January 2011
Resolution: Stowage are a properly marked.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 January 2011
Resolved
Adult and Child size life jackets are presently stowed together, provide separate stowage area for child size life jackets.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2011
Resolution: Child size life jackets properly stowed.
Lifesaving › Lifefloat › Lifeline
Issued 18 January 2011
Resolved
Lifefloat lifelines that connect the two floats together need to be made of buoyant material. Provide buoyant line for lifeline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 19 January 2011
Resolution: New buoyant line installed on Lifefloats. All sat.
Stability › Weathertight Integrity › General
Issued 18 January 2011
Resolved
Aft hatch dogs are wasted and no longer latch. Repair or renew aft hatch to ensure proper operation, hatch must be watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 21 January 2011
Resolution: New hatch dogs fabricated by local welder. Satisfactory operational test.
Engineering › Lubricating Oil Service System › Hose
Issued 18 January 2011
Resolved
Port red gear pump suction hose is wasted. Renew hose and ends with CG approved hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 21 January 2011
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 January 2011
Resolved
The Drug and Alcohol Testing program does not meet the requirements required by all applicable regulations. Provide proper Drug and Alcohol Testing program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 February 2011
Resolved 16 February 2011
Resolution: Operator implemented a new Drug and Alcohol program, using an approved consortium. All sat.
Lifesaving › Lifefloat › Serviceable
Issued 23 January 2007
Resolved
Repair grab line holders or replace (01) lifefloat. Vessel restricted to carrying 24 passengers.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 12 February 2007
Resolution: Vessel replaced lifefloat with new float.
Communications › Radio Communications › EPIRB
Issued 23 January 2007
Resolved
Replace EPIRB antenna. Vessel restricted to three nuatical miles.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 12 February 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 January 2007
Resolved
Replace lifeline for life ringbouy and floating light.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 23 January 2007
Communications › Alarms/Indicators › High Water Alarm
Issued 23 January 2007
Resolved
Label location of high water level bilge alarms at operator station
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 12 February 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 January 2007
Resolved
Add battery dates to floating lights.
Action required: 705 - Other - as specified
Due 23 February 2007
Resolved 12 February 2007
Construction/Loadline › Structures › Cofferdam
Issued 3 January 2006
Resolved
Make proper repairs to deck stringers as needed.
Action required: 705 - Other - as specified
Due 3 February 2006
Resolved 24 January 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 January 2005
Resolved
Provide 1 additional adult size PFD. Vessel is limited to not more than 49 total persons until completed.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 1 February 2005
Resolution: Completed. Received fax from owner attesting to completion of this requirement.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 January 2005
Resolved
Renew straps on 2 adult and 2 child PFD's.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 1 February 2005
Resolution: Completed. Received fax copy of invoice indicating completion of this requirement.
Lifesaving › Lifefloat › Painter
Issued 26 January 2005
Resolved
Renew lines attaching Lifefloats to painters.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 1 February 2005
Resolution: Completed. Received fax from owner attesting to completion of this requirement.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 January 2005
Resolved
Repair indicator lights for bilge high level alarms.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 1 February 2005
Resolution: Completed. Received fax copy of invoice and letter from owner attesting to completion of this requirement.
Lifesaving › Buoyant Apparatus
Issued 22 January 2004
Resolved
Make repairs to vessel's life floats in accordance with manufacturers recommendations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2004
Resolved 27 January 2004
Resolution: corrected.
Engineering › Bilge Water Management System › Piping
Issued 22 January 2004
Resolved
Replace with new PVC bilge pipe that runs through engine compartment from aft bilge pump in aft compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2004
Resolved 22 January 2004
Resolution: Replaced PVC pipe.
Engineering › Bilge Water Management System
Issued 22 January 2004
Resolved
Provide a longer hose for portable bilge pump capable of reaching the bottem of all compartments. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2004
Resolved 29 January 2004
Resolution: corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 January 2004
Resolved
Provide new lens cover for stern light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2004
Resolved 27 January 2004
Resolution: new lens
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 January 2004
Resolved
Provide navigation publications, U. S. Coast Pilot and Coast Guard Light List.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2004
Resolved 29 January 2004
Resolution: Corrected
Construction/Loadline › Structures
Issued 5 December 2002
Resolved
Renew gasket on forward hatch above the Vee-Berth. LEGACY COMPONENT DESC: Hatch covers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 2 December 2003
Resolution: Corrected.
Construction/Loadline › Structures
Issued 5 December 2002
Resolved
Adjust and repair watertight BOMAR hatch located between engne hatch covers. LEGACY COMPONENT DESC: Hatch covers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 2 December 2003
Resolution: Corrected.
Engineering › Shafting/Propeller Arrangements
Issued 5 December 2002
Resolved
Tighten starboard packing gland. LEGACY COMPONENT DESC: Stern Gland
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 2 December 2003
Resolution: Corrected.
Documentation › Markings/Placards
Issued 5 December 2002
Resolved
Post emergency broadcast placard at operating station near the VHF radio. LEGACY COMPONENT DESC: Emergency Broadcast Placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 2 December 2003
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 5 December 2002
Resolved
Submit annual MIS Drug Testing collection form.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 6 December 2002
Resolution: Requirement removed, Marine employer is exempt from reporting because there are less than 10 employees.
Electrical
Issued 10 December 1999
Resolved
Properly wire the washdown pump with an inline fuse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 2000
Resolved 22 December 1999
Documentation
Issued 10 December 1999
Resolved
Provide a vessel logbook with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 2000
Resolved 22 December 1999
Construction/Loadline
Issued 10 December 1999
Resolved
Install 2 additional high-level bilge alarms as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 2000
Resolved 22 December 1999
Lifesaving
Issued 10 December 1999
Resolved
Repair 8 adult and 2 child PFDs._x001C_ _x001C_ Passengers reduced to 40 adults and 3 children until this item corrected._x001C_ _x001C_
Condition: Unknown
Due 10 January 2000
Resolved 22 December 1999
Navigation
Issued 15 December 1998
Resolved
Replace the badly corroded rudder post support I-beam in the steering system._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 20 December 1993
Resolved
Replace 100' painter on lifefloat.
Condition: Unknown
Due 20 January 1994
Resolved 3 January 1994
Lifesaving
Issued 20 December 1993
Resolved
Lash paddles to lifefloats.
Condition: Unknown
Due 20 January 1994
Resolved 3 January 1994
Fire Fighting
Issued 20 December 1993
Resolved
Provide one B-I fire extinguisher at the steering station.
Condition: Unknown
Due 20 January 1994
Resolved 3 January 1994
Lifesaving
Issued 20 December 1993
Resolved
Replace 3 out of date day flares.
Condition: Unknown
Due 20 January 1994
Resolved 3 January 1994
Lifesaving
Issued 26 January 1993
Resolved
PROVIDE 2 ADDITIONAL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Lifesaving
Issued 26 January 1993
Resolved
REPLACE 60 FEET OF LINE ON RING BUOY.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Documentation
Issued 26 January 1993
Resolved
PROVIDE VALID FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Engineering
Issued 26 January 1993
Resolved
REPLACE HOSE CLAMPS ON EXHAUST SECTIONS AFT OF MUFFLERS.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Construction/Loadline
Issued 26 January 1993
Resolved
REPLACE COOLING WATER HOSE FROM STBD. SEA VALVE TO STRAINER.
Condition: Unknown
Due 26 January 1993
Resolved 26 January 1993
Engineering
Issued 29 June 1989
Resolved
RENEW FUEL HOSES WITH COPPER FUEL LINES WITH A MINIMUM WALL THICKNESS OF .035". HOSES SHALL NOT EXCEED 30" IN LENGTH.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989