Records from 2001 to 2021. Most recent: operational control imposed, 17 July 2021.
Inspection history · 37
17 July 2021
In-Service Inspection · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7261703
6 July 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7247613
11 June 2021
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7239660
14 January 2021
Ballast Water Examination · PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7122047
26 December 2019
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6871826
27 April 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6671410
26 February 2019
ISPS II Exam · Deficiency Check · Administrative Inspection · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6631925
26 February 2019
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6727661
29 November 2017
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6314413
18 May 2017
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6150266
30 September 2016
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6010570
4 November 2015
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5757074
25 August 2015
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5221700
5 February 2012
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4240138
17 February 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3947234
13 August 2008
MARPOL Annex V Examination · ISPS II Exam · NPV Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3296680
27 December 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3121281
21 December 2007
COC-GAS Renew · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3119203
29 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2945342
25 January 2007
Ballast Water Examination · COC-GAS Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2861719
24 January 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2861200
28 August 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2761745
23 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2722019
16 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2651061
6 April 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2618149
6 February 2006
ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2579836
5 February 2006
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2579439
28 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2575074
26 January 2006
ISPS I Exam · COC-GAS Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2573743
25 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2574074
21 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2570526
28 October 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2524170
26 October 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2522381
5 August 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2452273
22 January 2005
ISPS II Exam · COC-GAS Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278281
22 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293128
22 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1073398
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 26 February 2019
Resolved
Gas detection equipment should be so designed that it may readily be tested. Testing and calibration should be carried out at regular intervals. During PSC exam, vessel was unable to perform calibration or testing of fixed gas detection due to repairs being performed on equipment. Vessel must show satisfactory calibration and testing to satisfaction of Admin prior to cargo operations. 1993 IGC 13.6.6
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2019
Resolution: Sector Houston received a class report attesting to the replacement of required sensors and the satisfactory calibration of vessels fixed gas detection system. Class report is attached within documents tab.
Fire Fighting › Nozzles › Condition
Issued 5 February 2012
Resolved
On ships carrying flammable products, a water-spray system should be installed and operational, to cover cargo tank domes. Water-spray nozles covering tanks 4 stbd, 4 port, and 1 port were inoperable. IGC Code (1993 Ed.) CH 11.3.1
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2012
Resolved 5 February 2012
Resolution: Corrected prior to PSC team departing vessel.
Electrical › Electric Supply System (service) › Cable
Issued 5 February 2012
Resolved
Electrical installations should be such to minimize the risk of fire. Cargo Pump #1 starboard electrical ground was wasted away. IGC Code (1993 Ed.) CH 10.1.2
*Note - Vessel not scheduled to use cargo pump until next U.S. Port (Kahalui, Maui).
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2012
Resolved 5 February 2012
Resolution: Corrected prior to PSC team departing vessel.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 26 January 2006
Resolved
Renew/Replace two EEBD's in the engine room.
Condition: Unknown
Due 26 January 2006
Resolved 26 January 2006
Resolution: Corrected on the spot, renew from ship spares. Defective EEBD to be sent out for repairs.