MAURY USCG vessel records
← All vessels

ELKA ANGELIQUE

ELKA ANGELIQUE is a 2001 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in April 2021, along with 12 deficiencies — 1 with no resolution recorded — and 3 operational controls, 1 with no removal date recorded.

Records from 2016 to 2021. Most recent: inspection, 3 April 2021.

Built
2001
Last inspected
3 April 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 April 2021
…with no type recorded8
Operational controls 1 with no removal date recorded
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9216913
Flag
LIBERIA
Maury page id
psix-33218

Documentation record

Tonnage as PSIX records it44788 - Dead Weight, Metric Ton
54964 - Displacement, Metric Ton
27539 - Convention (Subpart B), Gross Ton
13092 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

3 April 2021 PSC A · COC-CHEM & TVE Annual · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7163745
30 March 2020 COC-CHEM & TVE Renew
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6936623
28 September 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6823231
4 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6703385
7 May 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6663851
15 June 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6445212
25 April 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6399089
3 April 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6384466
5 March 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6366275
23 September 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6273033
19 February 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6088683
16 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6089716
16 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6089723
24 November 2016 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6046972
28 July 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5955758
28 July 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5955821
15 April 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5860401
13 April 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5853402
13 April 2016 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5853774
9 February 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5810617

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2021 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions shall be taken to the satisfaction of the Administration. Cabling for numerous cargo pump tank top pressure sensors found deteriorated or with loose cable connections, throughout the cargo deck area. *Deficiency required to be rectified prior to cargo operations. SOLAS 74 (1997 Cons.) II-1/45.5.4 - 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2021
Resolved 9 April 2021
Resolution: Recieved satisfactory electrician report and class report attesting to rectification with new connectors and glands. Attended and examined equipment.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2021 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions shall be taken to the satisfaction of the Administration. Cabling for numerous high level/overfill alarms found with loose and improper connections. *Deficiency required to be rectified prior to cargo operations. SOLAS 74 (1997 Cons.) II-1/45.5.4 - 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2021
Resolved 6 April 2021
Resolution: Received class report attesting to satisfactory repairs, re-examined by PSC exam team.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2021 No resolution recorded
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions shall be taken to the satisfaction of the Administration. Steel conduit piping leading to tank radar sensors and overfill alarms throughout the cargo deck area, found wasted in numerous locations, especially aft cargo tanks. *Deficiency required to be rectified prior to cargo operations. SOLAS 74 (1997 Cons.) II-1/45.5.4 - 17 a/c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolution: Changed to code 40 on 06APR21. Recieved satisfactory class report, vessel effected repairs temporarily until upcoming yard period. No cargo resrictions for this deficiency at this time.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2021 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions shall be taken to the satisfaction of the Administration. Tank radar and cargo pump bonding straps found wasted at connections throughout cargo deck area. *Deficiency required to be rectified prior to cargo operations. SOLAS 74 (1997 Cons.) II-1/45.5.4 - 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2021
Resolved 6 April 2021
Resolution: Received class report attesting to satisfactory repairs, re-examined by PSC exam team.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2021 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions shall be taken to the satisfaction of the Administration. Tank washing heater controls by port slop tank, found wasted. *Deficiency required to be rectified prior to cargo operations. SOLAS 74 (1997 Cons.) II-1/45.5.4 - 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2021
Resolved 6 April 2021
Resolution: Received class report attesting to satisfactory repairs, re-examined by PSC exam team.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 April 2021 Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. As evidenced by deficiencies 01 through 05, the company has not established procedures or checklists to ensure that the cargo deck area is free of electrical hazards prior to cargo operations. External audit is recommended. SOLAS 74 (2020 Cons.) IX/3.1 – ISM Code 7 – 17 a/c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2021
Resolved 9 April 2021
Resolution: Changed to code 50 on 06APR21. Flag representative to provide CG with external audit, in progress. Reviewed audit on 09APR21 as conducted with observations and closed items.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 8 May 2019 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. PSCOs observed multiple factual inaccuracies in ORB Part 1 entries. For example, last weekly soundings in ORB, conducted on 07MAY2019, list the tank volumes as follows: fuel oil sludge tank 6.1 cubic meters, separator sludge tank 9.0 cubic meters, incinerator waste oil tank 0.0 cubic meters, and bilge holding tank 6.1 cubic meters. During tour of engine room on 07MAY2019, PSCO noted that incinerator waste oil tank was approximately 1/3 full. C/E subsequently transferred this sludge to fuel oil sludge tank and PSCOs observed the following soundings on 07MAY2019: fuel oil sludge tank 7.53 cubic meters, separator sludge tank 8.32 cubic meters, and bilge holding tank 7.13 cubic meters. Additionally, the engine logbook shows the OWS as operated on 17MAR2019 from 0814 to 1035. There is no entry in the ORB for the OWS being operated that day. MARPOL I/17.4 50bc
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2019
Resolved 4 June 2019
Resolution: Received proof of onboard training for ship's crew on proper ORB entries per MEPC.1/Circ.736 and ship SMS requirements. Vessel's flag state (Liberia) confirmed that record of onboard training satisfied the Administration.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 8 May 2019 Resolved
Oil residue (sludge) tank(s) shall be provided and: [.3] shall have no discharge connections to the bilge system, oily bilge water holding tank(s), tank top or oily water separators, except that: [.1] the tank(s) may be fitted with drains, with manually operated self closing valves and arrangements for subsequent visual monitoring of the settled water that lead to an oily bilge water holding tank... The incinerator waste oil/mixing tank listed on the IOPP as a oil residue (sludge) tank is not fitted with a manually operated self closing valve for the drainage of settled water leading to the bilge holding tank. MARPOL I/17.4 50bc
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2019
Resolved 4 June 2019
Resolution: Received DNG-GL class report which states that a manually operated self-closing valve has been fitted in the system to comply with MARPOL requirements.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 8 May 2019 Resolved
After any survey of the ship has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey, without the sanction of the Administration, except the direct replacement of such equipment and fittings. Incinerator waste oil mixing tank, listed on IOPP Form B section 3.1, has an approximately 1 foot long sludge drain line with a ball valve and open-ended pipe termination extending horizontally from the tank. This line is not shown on the ship's drawings (drawing number 31-703-402). MARPOL I/6.4.2 50ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2019
Resolved 4 June 2019
Resolution: Received DNV-GL class report which attests that the drain line has been removed and capped and the system's piping returned to the as-built drawing configuration/arrangement.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 7 May 2019 Resolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation [14.2]. Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization [MEPC.60(33)]. Section 6.1.1 states that recirculating facilities should be provided to enable the oil filtering equipment to be tested with the overboard discharge closed at initial and periodic surveys. The installed system does not allow for the oil filtering equipment (OWS) to be tested with the overboard discharge closed. MARPOL I/14 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 4 June 2019
Resolution: Received DNV-GL class report stating that the OWS piping has been modified (and a revised drawing approved by DNV-GL) to provide a recirculation pipe that drains into an open hopper for visual observation and then into the bilge tank.
Deck/Cargo › Cargo Heating › General
Issued 5 March 2018 Resolved
1836 - Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO's found two steam pipes on deck seperated and broken. Cite - 74 SOLAS (04) II-1/33 Action Taken - 40 AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 April 2018
Resolution: CG Sector Houston/Galveston PSC Branch received a class report from DNV-GL satisfying the requirement.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 February 2016 Resolved
74 SOLAS (14) VII/10.1 IBC Code, 14.3.4 Suitably marked decontamination showers and an eye wash shall be available on deck in convienient locations. The showers and eye wash shall be operable in all ambient conditions. PSCO found water line connecting eye wash/shower fractured, rendering it inoperable. Vessel is restricted from chemical cargo operations until deficiency is resolved.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 10 February 2016
Resolution: Sector San Juan conducted COC and cleared def.

Ownership record